GRUNDFOS PRODUCT GUIDE S pumps, range 50 13 to 18 hp 60 Hz ANSI
Transcript

GRUNDFOS PRODUCT GUIDE

S pumps, range 50

13 to 18 hp60 Hz ANSI

Contents

2

IntroductionIntroduction 3Applications 3Main constructional features 4

Performance rangePerformance range, S pumps 5Performance range, S pumps, range 50 5

IdentificationType key 6Pump nameplate 7FM approval plate 7

Selection of productOrdering a pump 8

Product rangeStandard range 9Standard range with stainless steel impeller 10Explosion proof range 11Explosion proof range with stainless steel impeller 12

VariantsList of variants 13

ConstructionSectional drawings, motors 14Sectional drawings, pumps 18Components and material specification 24

Product descriptionFeatures 25Operating conditions 26Motor range 26Explosion-proof pumps 27Pump controllers 27Wiring diagrams 28

Curve charts/Technical dataHow to read the curve charts 30Curve conditions 31Performance tests 31Certificates 31Witness test 31

Performance curvesTechnical dataS 50 SuperVortex, 2-pole 32S 50 low pressure, 4-pole 34S 50 medium pressure, 4-pole 36S 50 high pressure, 4-pole 38

AccessoriesAccessories (for installation) 40Other accessories 41

DimensionsInstallation on auto coupling 42Installation on ring stand 46Dry-pit, vertical installation 48Dry-pit, horisontal installation 50

Further product documentationWebCAPS 52WinCAPS 53

S pumps, range 50Introduction

IntroductionThis product guide deals with Grundfos heavy-duty sewage pumps called S pumps, range 50.

This product guide was printed in July 2010. A newer version might be available from Grundfos WebCAPS. Go to WebCAPS Literature to locate and download the latest version - or insert the link below directly in your browser to get to the download page:

http://net.grundfos.com/Appl/WebCAPS/

Using the PDF version of this data booklet offers extra features to the booklet. Double-clicking a product number listed in the data booklet will open an internet browser window displaying all technical information available on the product.

Fig. 1 S pump, range 50

The S pumps, range 50, are a range of free-flow (SuperVortex) and channel impeller pumps specifically designed for pumping sewage and wastewater in a wide range of municipal, private and industrial applica-tions.

The pumps are made of resistant materials, such as cast iron and stainless steel. These materials ensure a proper operation.

The pumps are fitted with motors from 13 up to 18 hp (10 kW up to 13.5 kW). The motors are either 2- or 4-pole motors, depending on the motor size.

The free passage in the pumps is 3 to 4" (80 to 100 mm).

The pumps are available for:

• submerged installation on auto-coupling system• submerged installation, free-standing• dry-pit installation, vertical• dry-pit installation, horizontal.

ApplicationsThe S pumps, range 50, are designed for applications, such as:

• raw water intake• wastewater treatment plants• municipal pumping stations • public buildings • residential housing• blocks of apartments• industries• parking garages • underground car parks • car wash areas • restaurants and hotels. The pumps are suitable for both temporary and perma-nent installation. The lifting bracket fitted on the pumps facilitates easy transportation to as well as installation at the installation site.

GrA

7834

3

Introduction S pumps, range 50

4

Main constructional features• leak-proof connections via the Grundfos SmartSeal

gasket system• double mechanical shaft seal system for reliable

sealing between pumped liquid and motor• watertight cable entry of corrosion-resistant polya-

mide or cast iron for FM approved pumps• moisture switch for continuous monitoring of motor

housing and automatic cut-off of power in case liq-uid penetrates

• self-cleaning channel impeller with long vanes re-ducing the risk of jamming or clogging, or SuperVor-tex impeller with high pumping efficency and less downtime

• SmartTrim system allowing easy adjustment of im-peller clearance and maintaining maximum pump efficiency over pump lifetime

• motor in insulation class H (356 °F (180 °C)), enclo-sure class IP68 with three thermal sensors in stator windings

• seal condition monitoring via water-in-oil sensor (optional)

• explosion-proof motors for applications involving high risk of explosion

• stainless steel versions for use in corrosive or ag-gressive liquids:Q: stainless steel impeller, cast iron pump and mo-tor housing.

S pumps, range 50

5

Performance range

Performance range, S pumps

Performance range, S pumps, range 50

TM04

655

7 06

10TM

04 6

605

0610

100 150 200 300 400 500 8001000 1500 2000 3000 5000 10000 15000

Q [US GPM]

6

8

10

15

20

30

40

60

80

100

150

200

300

[ft]H

1010 20 30 40 50 60 7080 100100 200 300 400 600 800Q [l/s]

2

3

4

5

6

8

1010

20

30

40

50

60

80

[m]H

60 Hz

50

54

58

62

66

70

20000

0 200 400 600 800 1000 1200 1400 1600 1800 2000

Q [US GPM]

15

20

25

30

40

50

60

80

100

150

[ft]H

0 20 40 60 80 100 Q [l/s]

5

6

7

8

9

1010

20

30

40

[m]H

60 Hz

S PumpsRange 50

S1.40.A40

S1.40.A50

SV.30.A30

S1.30.A40

6

S pumps, range 50Identification

Type keyCode Example S 1 .40 .A40 .134 4 .50M .H .205 .G .N .D .Z

SST

Pump type:Grundfos sewage and wastewater pumpMulti-channel impeller pump installed in a column pipe

1V

Impeller type:Single-channel impellerSuperVortex (free-flow) impeller

Pump passage:Maximum solids size = Code number from type designation/10 [inch]

A40

Pump discharge:Nominal diameter of pump discharge port = Code number from type designation/10 [inch]4"

Output power, P2:P2 = Code number from type designation/10 [hp]

24

Number of poles: 2-pole motor4-pole motor

50S50H50M50L50E50F

Pump range / Pressure version:Super-high pressureHigh pressureMedium pressureLow pressureExtra-low pressureSuper-low pressure

SCDH

Installation:Submersible installation without cooling jacketSubmersible installation with cooling jacketDry installation, verticalDry installation, horizontal.

Actual impeller diameter:[mm]

GRSQD

Material code for impeller, pump and motor housing:Impeller, pump housing and motor housing: Cast ironImpeller, pump housing and motor housing: Stainless steel AISI 316 (DIN W.-Nr. 1.4408)Impeller and pump housing: Stainless steel AISI 316 (DIN W.-Nr. 1.4408)Impeller: Stainless steel AISI 316 (DIN W.-Nr. 1.4408)Impeller: Duplex steel.

NEx

Pump version:Non-explosion-proof pumpExplosion-proof pump

BCD

Sensor version:B =S pump with built-in SM 111 module. PTC sensors are connected directly to IO 111 or other PTC relay.C =Not in useD =S pump without built-in SM 111 module.

Z Custom-built products

Identification S pumps, range 50

Pump nameplate

Fig. 2 Pump nameplate

FM approval plate

Fig. 3 Ex approval plate

The approval plate gives the following details:

TM04

649

4 12

10

Pos. Description

1 Type designation2 SAP code 3 Serial number4 Maximum ambient temperature5 Maximum head6 Maximum flow7 Maximum installation depth8 Enclosure class9 Number of phases

10 Frequency11 Rated speed12 Voltage/current, delta connection13 Voltage/current, star connection14 Power input/output15 Service factor16 Power factor17 Insulation class18 Production code, year/week19 Weight of the pump20 Model

2

1

3579

1013141618

20468

1112

1719

15

TM04

649

5 02

10

FM-symbol

II Equipment group (II = non-mining)2 Equipment category (high protection)G Type of explosive atmosphereCE CE mark1180 Number of quality assurance notified bodyEx Motor explosion-proof according to FM standardb Control of ignition sourcesc Constructional safetyd Motor withstands explosion pressureIIB Gas group (Ethylene)T3C Maximum surface temperature of the motor is

320 °F (160 °C)T4 Maximum surface temperature of the motor is

275 °F (135 °C)Gb Equipment protection level, zone 1Baseefa Certificate numberFM Certificate number

FM

7

S pumps, range 50

8

Selection of product

Ordering a pumpWhen ordering an S pump, range 50, you need to take the following four aspects into consideration.

1. Pump2. Custom-built variation (option)3. Accessories4. Controller.

PumpUse the selection tool in WebCAPS to find the best suited pump for your application or use section Product range on page 9 and section Type key on page 6 to identify the pump that best fulfils your needs. The list below is a detailed description of the product you get if you order the following pump:

• Pump as specified in the type key• 50 ft (15 m) cable• Paint: Graphic grey, NCS S8005-R80B, thickness

150 μ • Three thermal switches (Klixon), one in each phase,

or three thermal sensors (PTC)• One moisture switch below the motor top cover (two

moisture switches below the motor top cover on explosion-proof versions)

• ANSI-HI centrifugal pump test 1.6-2000, Acceptance level B.

See section Performance curves Technical data for selection of a standard pump.

Note: Product specific data for the pump can also be seen in WebCAPS using the product number 97631999.

Custom-built variantsThe S pumps can be customised to meet individual requirements. Many pump features and options are available for customisation, e.g. explosion-proof versions, various cable lengths or special materials.

Variants can be seen in section List of variants on page 12. For requirements or designs not included in the list, contact Grundfos.

AccessoriesDepending on the installation type, you may need to order accessories. See section Accessories on page 48 for selection of the correct accessories.

Note: Ordered accessories are not fitted from factory.

ControllerThe following controllers are available:

Grundfos Dedicated Controls (DC).Pump Product noS1.30.A40.134.4.50H.H.212.G.N.D 97631999

S pumps, range 50Product range

Standard range

* The horizontal base stand is included in the pump product number.

Pump type

Pump Accessories

3x460 V 3x230 V Explosion proof

To be ordered separately*Horizontal base stand

Vertical base stand

Auto-coupling system

Ring stand for portable use

S1.30.A40.134.4.50H.S.212.G.N.D 97631994 97631995 N - - 97626238 96846769S1.30.A40.134.4.50H.C.212.G.N.D 97631996 97631997 N - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.212.G.N.D 97631998 97631999 N 96844857 - - -S1.30.A40.134.4.50H.S.200.G.N.D 97632012 97632013 N - - 97626238 96846769S1.30.A40.134.4.50H.C.200.G.N.D 97632014 97632015 N - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.200.G.N.D 97632016 97632017 N 96844857 - - -S1.30.A40.147.4.50H.S.222.G.N.D 97632018 97632019 N - - 97626238 96846769S1.30.A40.147.4.50H.C.222.G.N.D 97632020 97632021 N - 96845469 97626238 96846769S1.30.A40.147.4.50H.H.222.G.N.D 97632022 97632023 N 96844857 - - -S1.30.A40.181.4.50H.S.239.G.N.D 97632024 97632025 N - - 97626238 96846769S1.30.A40.181.4.50H.C.239.G.N.D 97632026 97632027 N - 96845469 97626238 96846769S1.30.A40.181.4.50H.H.239.G.N.D 97632028 97632029 N 96844857 - - -S1.40.A40.134.4.50M.S.205.G.N.D 97632006 97632007 N - - 97626238 96848863S1.40.A40.134.4.50M.C.205.G.N.D 97632008 97632009 N - 96308238 97626238 96848863S1.40.A40.134.4.50M.H.205.G.N.D 97632010 97632011 N 96776517 - - -S1.40.A40.181.4.50M.S.221.G.N.D 97632036 97632037 N - - 97626238 96848863S1.40.A40.181.4.50M.C.221.G.N.D 97632038 97632039 N - 96308238 97626238 96848863S1.40.A40.181.4.50M.H.221.G.N.D 97632040 97632041 N 96776517 - - -S1.40.A50.134.4.50L.S.204.G.N.D 97632000 97632001 N - - 97626242 96848864S1.40.A50.134.4.50L.C.204.G.N.D 97632002 97632003 N - 96308238 97626242 96848864S1.40.A50.134.4.50L.H.204.G.N.D 97632004 97632005 N 96776517 - - -S1.40.A50.181.4.50L.S.224.G.N.D 97632030 97632031 N - - 97626242 96848864S1.40.A50.181.4.50L.C.224.G.N.D 97632032 97632033 N - 96308238 97626242 96848864S1.40.A50.181.4.50L.H.224.G.N.D 97632034 97632035 N 96776517 - - -SV.30.A30.139.2.50H.S.159.G.N.D 97632042 97632043 N - - 97626239 96844859SV.30.A30.168.2.50H.S.172.G.N.D 97632044 97632045 N - - 97626239 96844859

9

Product range S pumps, range 50

10

Standard range with stainless steel impeller

* The horizontal base stand is included in the pump product number.

Pump type

Pump Accessories

3x460 V 3x230 V Explosion proof

To be ordered separately***Horizontal base stand

Vertical base stand

Auto-coupling system

Ring stand for portable use

S1.30.A40.134.4.50H.S.212.Q.N.D 97647648 97647649 N - - 97626238 96846769S1.30.A40.134.4.50H.C.212.Q.N.D 97647650 97647731 N - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.212.Q.N.D 97647732 97647733 N 96844857 - - -S1.40.A40.134.4.50M.S.205.Q.N.D 97647734 97647735 N - - 97626238 96848863S1.40.A40.134.4.50M.C.205.Q.N.D 97647736 97647737 N - 96308238 97626238 96848863S1.40.A40.134.4.50M.H.205.Q.N.D 97647738 97647739 N 96776517 - - -S1.30.A40.134.4.50H.S.200.Q.N.D 97647740 97647741 N - - 97626238 96846769S1.30.A40.134.4.50H.C.200.Q.N.D 97647742 97647743 N - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.200.Q.N.D 97647744 97647745 N 96844857 - - -S1.30.A40.147.4.50H.S.222.Q.N.D 97647746 97647747 N - - 97626238 96846769S1.30.A40.147.4.50H.C.222.Q.N.D 97647748 97647749 N - 96845469 97626238 96846769S1.30.A40.147.4.50H.H.222.Q.N.D 97647750 97647751 N 96844857 - - -S1.30.A40.181.4.50H.S.239.Q.N.D 97647752 97647753 N - - 97626238 96846769S1.30.A40.181.4.50H.C.239.Q.N.D 97647754 97647755 N - 96845469 97626238 96846769S1.30.A40.181.4.50H.H.239.Q.N.D 97647756 97647757 N 96844857 - - -S1.40.A50.134.4.50L.S.204.Q.N.D 97661404 97661405 N - - 97626242 96848864S1.40.A50.134.4.50L.C.204.Q.N.D 97661406 97661407 N - 96308238 97626242 96848864S1.40.A50.134.4.50L.H.204.Q.N.D 97661408 97661409 N 96776517 - - -S1.40.A50.181.4.50L.S.224.Q.N.D 97647758 97647759 N - - 97626242 96848864S1.40.A50.181.4.50L.C.224.Q.N.D 97647760 97647761 N - 96308238 97626242 96848864S1.40.A50.181.4.50L.H.224.Q.N.D 97647762 97647763 N 96776517 - - -S1.40.A40.181.4.50M.S.221.Q.N.D 97647764 97647765 N - - 97626238 96848863S1.40.A40.181.4.50M.C.221.Q.N.D 97647766 97647767 N - 96308238 97626238 96848863S1.40.A40.181.4.50M.H.221.Q.N.D 97647768 97647769 N 96776517 - - -SV.30.A30.139.2.50H.S.159.Q.N.D 97647770 97647771 N - - 97626239 96844859SV.30.A30.168.2.50H.S.172.Q.N.D 97647772 97647773 N - - 97626239 96844859

Product range S pumps, range 50

Explosion proof range

* The horizontal base stand is included in the pump product number.

Pump type

Pump Accessories

3x460 V 3x230 V Explosion proof

To be ordered separately*Horizontal base stand

Vertical base stand

Auto-coupling system

Ring stand for portable use

S1.30.A40.134.4.50H.S.212.G.Ex.D 97660599 97660600 Y - - 97626238 96846769S1.30.A40.134.4.50H.C.212.G.Ex.D 97660621 97660622 Y - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.212.G.Ex.D 97660623 97660624 Y 96844857 - - -S1.30.A40.134.4.50H.S.200.G.Ex.D 97660637 97660638 Y - - 97626238 96846769S1.30.A40.134.4.50H.C.200.G.Ex.D 97660639 97660640 Y - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.200.G.Ex.D 97660641 97660642 Y 96844857 - - -S1.30.A40.147.4.50H.S.222.G.Ex.D 97660643 97660644 Y - - 97626238 96846769S1.30.A40.147.4.50H.C.222.G.Ex.D 97660645 97660646 Y - 96845469 97626238 96846769S1.30.A40.147.4.50H.H.222.G.Ex.D 97660647 97660648 Y 96844857 - - -S1.30.A40.181.4.50H.S.239.G.Ex.D 97660649 97660650 Y - - 97626238 96846769S1.30.A40.181.4.50H.C.239.G.Ex.D 97660651 97660652 Y - 96845469 97626238 96846769S1.30.A40.181.4.50H.H.239.G.Ex.D 97660653 97660654 Y 96844857 - - -S1.40.A40.134.4.50M.S.205.G.Ex.D 97660631 97660632 Y - - 97626238 96848863S1.40.A40.134.4.50M.C.205.G.Ex.D 97660633 97660634 Y - 96308238 97626238 96848863S1.40.A40.134.4.50M.H.205.G.Ex.D 97660635 97660636 Y 96776517 - - -S1.40.A40.181.4.50M.S.221.G.Ex.D 97660661 97660662 Y - - 97626238 96848863S1.40.A40.181.4.50M.C.221.G.Ex.D 97660663 97660664 Y - 96308238 97626238 96848863S1.40.A40.181.4.50M.H.221.G.Ex.D 97660665 97660666 Y 96776517 - - -S1.40.A50.134.4.50L.S.204.G.Ex.D 97660625 97660626 Y - - 97626242 96848864S1.40.A50.134.4.50L.C.204.G.Ex.D 97660627 97660628 Y - 96308238 97626242 96848864S1.40.A50.134.4.50L.H.204.G.Ex.D 97660629 97660630 Y 96776517 - - -S1.40.A50.181.4.50L.S.224.G.Ex.D 97660655 97660656 Y - - 97626242 96848864S1.40.A50.181.4.50L.C.224.G.Ex.D 97660657 97660658 Y - 96308238 97626242 96848864S1.40.A50.181.4.50L.H.224.G.Ex.D 97660659 97660660 Y 96776517 - - -SV.30.A30.139.2.50H.S.159.G.Ex.D 97660667 97660668 Y - - 97626239 96844859SV.30.A30.168.2.50H.S.172.G.Ex.D 97660669 97660670 Y - - 97626239 96844859

11

Product range S pumps, range 50

12

Explosion proof range with stainless steel impeller

* The horizontal base stand is included in the pump product number.

Pump type

Pump Accessories

3x460 V 3x230 V Explosion proof

To be ordered separately***Horizontal base stand

Vertical base stand

Auto-coupling system

Ring stand for portable use

S1.30.A40.134.4.50H.S.212.Q.Ex.D 97663570 97663591 Y - - 97626238 96846769S1.30.A40.134.4.50H.C.212.Q.Ex.D 97663592 97663593 Y - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.212.Q.Ex.D 97663594 97663595 Y 96844857 - - -S1.40.A40.134.4.50M.S.205.Q.Ex.D 97663602 97663603 Y - - 97626238 96848863S1.40.A40.134.4.50M.C.205.Q.Ex.D 97663604 97663605 Y - 96308238 97626238 96848863S1.40.A40.134.4.50M.H.205.Q.Ex.D 97663606 97663607 Y 96776517 - - -S1.30.A40.134.4.50H.S.200.Q.Ex.D 97663608 97663609 Y - - 97626238 96846769S1.30.A40.134.4.50H.C.200.Q.Ex.D 97663610 97663611 Y - 96845469 97626238 96846769S1.30.A40.134.4.50H.H.200.Q.Ex.D 97663612 97663613 Y 96844857 - - -S1.30.A40.147.4.50H.S.222.Q.Ex.D 97663614 97663615 Y - - 97626238 96846769S1.30.A40.147.4.50H.C.222.Q.Ex.D 97663616 97663617 Y - 96845469 97626238 96846769S1.30.A40.147.4.50H.H.222.Q.Ex.D 97663618 97663619 Y 96844857 - - -S1.30.A40.181.4.50H.S.239.Q.Ex.D 97663620 97663621 Y - - 97626238 96846769S1.30.A40.181.4.50H.C.239.Q.Ex.D 97663622 97663623 Y - 96845469 97626238 96846769S1.30.A40.181.4.50H.H.239.Q.Ex.D 97663624 97663625 Y 96844857 - - -S1.40.A50.134.4.50L.S.204.Q.Ex.D 97663596 97663597 Y - - 97626242 96848864S1.40.A50.134.4.50L.C.204.Q.Ex.D 97663598 97663599 Y - 96308238 97626242 96848864S1.40.A50.134.4.50L.H.204.Q.Ex.D 97663600 97663601 Y 96776517 - - -S1.40.A50.181.4.50L.S.224.Q.Ex.D 97663626 97663627 Y - - 97626242 96848864S1.40.A50.181.4.50L.C.224.Q.Ex.D 97663628 97663629 Y - 96308238 97626242 96848864S1.40.A50.181.4.50L.H.224.Q.Ex.D 97663630 97663631 Y 96776517 - - -S1.40.A40.181.4.50M.S.221.Q.Ex.D 97663632 97663633 Y - - 97626238 96848863S1.40.A40.181.4.50M.C.221.Q.Ex.D 97663634 97663635 Y - 96308238 97626238 96848863S1.40.A40.181.4.50M.H.221.Q.Ex.D 97663636 97663637 Y 96776517 - - -SV.30.A30.139.2.50H.S.159.Q.Ex.D 97663638 97663639 Y - - 97626239 96844859SV.30.A30.168.2.50H.S.172.Q.Ex.D 97663640 97663641 Y - - 97626239 96844859

S pumps, range 50

13

Variants

List of variants

Motor

Various cable lengths82 ft (25 m)165 ft (50 m)

EMC power cables Screened power cables for variable speed drives

33 ft (10 m)50 ft (15 m)82 ft (25 m)165 ft (50 m)

Special motor Special voltagePTC thermistors in windingsSpecial oil Non-toxic Shell Ondina 917

Motor protectionPTC + moisture switch FPV1Klixon + moisture switch + WIO FPV2aPTC + moisture switch + WIO FPV2bKlixon + moisture switch + WIO + PT100 at lower bearing FPV3aPTC + moisture switch + WIO + PT100 at lower bearing FPV3b

MaterialsStainless steel lifting bracket AISI 316 Stainless steel impeller Variant QStainless steel impeller and pump housing Variant S Stainless steel Impeller, pump housing and motor housing Variant R

Tests

Test at specified duty on standard impeller curve

Trimmed impeller for specified duty test Additional test of entire QH curve (incl. report) 5-10 flows from pump performance curve

Different test standard Efficiency guaranteed by GrundfosISO 9906 grade 1 tolerancesISO 9906 grade 2 tolerances

Vibration test (incl. report) According to Grundfos factory quality standardPerformance test on dry test stand Not yet availableNPSHr test Not yet availableString test Contact GrundfosWitness test Contact Grundfos

MiscellaneousSpecial packaging Contact GrundfosSpecial nameplate Contact GrundfosOther variants Contact Grundfos

14

S pumps, range 50Construction

Sectional drawings, motors

Fig. 4 Non-explosion-proof motor without cooling jacket

TM04

171

9 10

08

Construction S pumps, range 50

Fig. 5 Non-explosion-proof motor with cooling jacket

TM04

172

0 10

08

15

Construction S pumps, range 50

16

Fig. 6 Explosion-proof motor without cooling jacket

TM04

172

1 10

08

Construction S pumps, range 50

Fig. 7 Explosion-proof motor with cooling jacket

TM04

172

2 10

08

17

Construction S pumps, range 50

18

Sectional drawings, pumps

Fig. 8 S1 pump

TM04

171

5 10

08

Construction S pumps, range 50

Fig. 9 SV pump

TM04

171

6 10

08

19

Construction S pumps, range 50

20

Fig. 10 Installation type S and C pump on auto coupling

TM04

194

0 14

08

Construction S pumps, range 50

Fig. 11 Installation type D pump

TM04

194

1 14

08

21

Construction S pumps, range 50

22

Fig. 12 Installation type S and C pump, free-standing

TM04

194

2 14

08

Construction S pumps, range 50

Fig. 13 S1 pump, installation type H

Fig. 14 SV pump, installation type H

TM04

171

4 10

08TM

04 1

718

1008

23

Construction S pumps, range 50

24

Components and material specification

Motor

Pump

Accessories

* Ex versions have cast iron cable entry and two moisture switches.** Available of stainless steel (custom-built option).

Pos. Component Material (AISI/DIN W.-Nr.)7a Rivet Stainless steel (316/1.4436)

25a Screw Stainless steel (316/1.4436)

25 Pressure test plug Stainless steel (316/1.4436)

48 Stator lamination

**55 Stator housing Cast iron (EN-JL 1040/A48 30)

58 Seal housing Cast iron

60 Bearing bracket cover Cast iron

61c Upper bearing bracket Cast iron

72a O-ring NBR rubber

72 O-ring NBR rubber

76a Approval plate

100 O-ring NBR rubber

105b Mechanical seal SiC/SiC or SiC/carbon

105 Mechanical seal SiC/SiC or SiC/carbon

150c Cooling jacket Galvanised steel

153 Ball bearing Stainless steel

154 Ball bearing Stainless steel

**155 Lower bearing bracket Cast iron

157b O-ring NBR rubber

157 O-ring NBR rubber

**164a Motor top cover Cast iron

*168 Cable entry PA or cast iron

172 Shaft with rotor Stainless steel (329/1.4462)

173b Earth terminal

173c Washer Stainless steel (316/1.4436)

173e Screw Stainless steel (316/1.4436)

173f Spring washer Stainless steel (316/1.4436)

173g Earth connector

173 Screw Stainless steel (316/1.4436)

176a Terminal block

176b Screw Stainless steel (316/1.4436)

176c Terminal block

176d Terminal block

178 Screw Stainless steel (316/1.4436)

180 Cable clamp PA or cast iron

181a Screw Stainless steel (316/1.4436)

181 Cable ATON

182b Hexagon socket head cap screw Stainless steel (316/1.4436)

184b Screw Stainless steel (316/1.4436)

184 Screw Stainless steel (316/1.4436)

187a Washer Stainless steel (316/1.4436)

187 Circlip

188 Circlip

190 Lifting bracket Stainless steel (316/1.4408)

193 Plug Stainless steel (316/1.4408)

194 O-ring NBR rubber

197 Washer Stainless steel (316/1.4436)

198 Rubber seal

248 Screw Stainless steel (316/1.4436)

250a Cable entry PA or cast iron

250b Rubber seal

250 Cable clamp PA or cast iron

252 Cable ATON

520a Screw Stainless steel (316/1.4436)

520b Nut Stainless steel (316/1.4436)

*520 Moisture switch

522 Holder

Pos. Component Material (AISI/DIN W.-Nr.)7a Rivet

9a Key (for keyway) Stainless steel (316/1.4436)

12c Adjusting screw Stainless steel (316/1.4436)

26 Screw Stainless steel (316/1.4436)

37 O-ring NBR rubber

37b O-ring NBR rubber

**49 Impeller Cast iron EN-JL 1050

**50 Volute casing Cast iron EN-JS 1050

67 Impeller screw Stainless steel (316/1.4436)

76 Nameplate

301 Motor housing

494 Plug Stainless steel (316/1.4436)

495 O-ring NBR rubber

Pos. Component Material

**701 Auto-coupling base unit Cast iron

**702 Guide rail bracket Cast iron

**703 Guide claw Cast iron

731 Base stand, vertical Galvanised steel

749 Bend Cast iron

751 Ring stand Galvanised steel

**761 Hose connector Cast iron or stainless steel

487 Base stand, horizontal Galvanised steel

799 Anchor bolt

Pos. Component Material (AISI/DIN W.-Nr.)

S pumps, range 50Product description

FeaturesSmartTrimOn conventional pumps, maintaining factory-set impeller clearance is a time-consuming and costly task. The pumps need to be disconnected from the pipework and to be totally dismantled, and new parts need to be mounted in order to maintain full pumping efficiency. Not so with Grundfos SmartTrim!

All Grundfos heavy-duty channel-impeller pumps, whether for submerged or dry installation, are equipped with the unique SmartTrim impeller clearance adjustment system. This enables you to easily restore factory-set impeller clearance and maintain peak pumping efficiency. All you need to do is to tighten the adjustment screws on the exterior of the impeller housing. This can be done on site, quickly and easily, without dismantling the pump and without using special tools.

A: With Grundfos SmartTrim impeller clearance adjustment system

B: Without impeller clearance adjustment system

SmartSealFor pumps with 10" discharge or larger, the Grundfos SmartSeal auto-coupling gasket mounted on the pump discharge flange provides a completely leak-proof connection between the pump and the base unit of the auto-coupling system. This optimises the efficiency of the entire pumping system and keeps operating costs at a minimum.

Ball bearingsThe bearings are greased for life.

Main bearings: Double-row angular contact ball bearing.

Support bearings: Single-row deep-groove ball bearing.

Shaft sealThe pumps have a shaft seal consisting of a primary and a secondary shaft seal.

The material combination of the primary shaft seal of all pump types is silicon carbide/silicon carbide. For the secondary shaft seal, the mateial combination is silicon carbide/carbon.

The shaft seals are placed in the oil chamber of the pump. The oil chamber provides reliable sealing between the pumped liquid and the motor.

The shaft seals have no springs or other parts in direct contact with the pumped liquid. This prevents rags and fibres from getting caught. The shaft seals are bidirectional, meaning that they can operate in either direction thus allowing for opposite rotation caused by back-flow of liquid through the pump.

MotorThe motor is a watertight, totally encapsulated motor with:

• insulation class H (356 °F (180 °C))• temperature rise class F (221 °F (105 °C))• enclosure class IP68.For motor protection and sensors, see section Sensors below.

Power cables

Standard cable

EMC cable

Control cable

The cables are 40 ft (15 m) long as standard. Other cable lengths are available on request. See section List of variants on page 12.

The number and dimension of cables depend on the motor size.

TM04

239

1 25

08

Factory-set impeller clearance

Efficiency drop in %

Years

B

A

0

3

6

9

12

15

1 2 3 4 5 Cable type[mm2]

Outer cable diameter[inch (mm)]

Bending radius

min. max. [inch (mm)]7 x 1.5 0.57 (14.4) 0.65 (16.4) 4 (100)4 x 2.5 0.66 (16.7) 0.74 (18.7) 4.7 (120)4 x 6 0.62 (15.7) 0.68 (17.2) 4.3 (110)

Cable type[mm2]

Outer cable diameter[inch (mm)]

Bending radius

min. max. [inch (mm)]3 x 6 0.54 (13.6) 0.6 (15.2) 3 (76)

Cable type[mm2]

Outer cable diameter[inch (mm)]

Bending radius

min. max. [inch (mm)]

7 x 1.5 0.57 (14.4) 0.63 - 0.65(16.0 - 16.4) 4 (100)

25

Product description S pumps, range 50

26

Cable entryWatertight PA or cast iron cable entry with soft shape and sealing rings to prevent damage of the cable or leaks.

SensorsAs standard the pump is equipped with:

• Three thermal switches (Klixon), one in each phase.• One moisture switch in a terminal block.

Customised sensor optionWIO (water-in-oil) sensorThe WIO sensor measures the water content in the oil and converts the value into an analogue current signal. The two sensor conductors are for power supply as well as for carrying the signal to the measuring device or controller. The sensor measures the water content from 0 to 20 %. It also sends a signal if the water content is outside the normal range (warning), or if there is air in the oil chamber (alarm). The sensor is fitted in a stainless steel tube for mechanical protection.The WIO sensor is connected to the Grundfos IO 111 module.

TestingAll pumps are tested before leaving the factory. The factory test report is based on ANSI-HI Centrifugal pump test 1.6-2000 Acceptance level B. Test reports can be ordered directly with the pump or can be ordered separately based on the pump serial number.

Other tests or third party inspection certificates are available on request including HI B & A Standards. See section List of variants on page 12.

Operating conditionsPumps without cooling jacket in submerged installation:• Continuous operation when pump is fully sub-

merged to top of motor.• Intermittent operation with max. 20 starts per hour

when pump is submerged to middle of motor and with short periods of operation down to the top of the pump housingNote: Explosion proof pumps must always be fully submerged

Pumps with cooling jacket in submerged and dry installation:• Continuous and intermittent operation with max. 20

starts per hour with water level down to the top of the pump housing.

Pumped liquidspH value: 4-10.

Liquid temperature: 32 °F - 104 °F (0 °C - +40 °C).

When pumping liquids with a density and/or a kinematic viscosity higher than that of water, use motors with correspondingly higher outputs.

Sound pressureThe sound pressure level of the pump is lower than the limiting values stated in the EC Council directive 2006/42/EC relating to machinery (the EC Machinery Directive).

Motor rangeShaft power [hp (kW)] No. of poles

13.4 (10.0) 413.9 (10.4) 214.7 (11.0) 416.8 (12.5) 218.1 (13.5) 4

Product description S pumps, range 50

Explosion-proof pumps

Approval standardsThese pumps are approved by FM according to FM3600, FM3615 and FM3615.80.

Explanation to FM approvalThe S pumps have the following explosion protection classification: Class I, Division 1, Groups C and D, T4, T3, IP68

Pump controllersS pumps, range 50 can be controlled by Grundfos Dedicated Controls (DC).

The Grundfos Dedicated Controls system can control from one to six pumps.

The Dedicated Controls system starts/stops the S pumps by means of:

• float switches,• pressure sensor or• ultrasonic sensor.Furthermore, it is possible to control the water level by both float switches and an analog pressure sensor or ultrasonic sensor.

Optionally, it can control a mixer and/or a flush valve. The Dedicated Controls system can be extended with an IO 111 module per pump (for S pumps with built-in analog sensor).

For further settings, see the installation and operating instructions for the pump controller selected.

Standards Code Description

FM3600FM3615FM3615.80

Class I Explosive atmosphere is caused by gas or vapours.

Division 1 Area classification

Groups C and D

Classification of gases

T4/T3 Maximum surface temperature is 275 °F (135 °C) and 392 °F (200 °C).

IP68 Enclosure class according to IEC 60529.

27

Product description S pumps, range 50

28

Wiring diagrams

Fig. 15 Wiring diagrams, Y-connected (230 V)

TM04

672

0 0

810

Sens

ors

Ther

mal

sw

itch

Moi

stur

e sw

itche

s

PT1

00 lo

wer

bea

ring

PT1

00 s

tato

r

Ther

mis

tor

Pow

er c

able M

otor

Product description S pumps, range 50

Fig. 16 Wiring diagrams, Y-connected (460 V)

TM04

671

9 0

810

Sens

ors

Ther

mal

sw

itch

Moi

stur

e sw

itche

s

PT1

00 lo

wer

bea

ring

PT1

00 s

tato

r

Ther

mis

tor

Pow

er c

able M

otor

29

30

S pumps, range 50Curve charts/Technical data

The following many pages are divided into sections:

How to read the curve charts

Pages 30 and 31 A brief explanation of how to read the curve charts, the curve conditions, etc.

Performance curves and technical data:Page 32 Pumps with SuperVortex impellerPage 34 Low pressurePage 36 Medium pressurePage 38 High pressure

TM04

655

8 06

100 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

100

[ft]H

0 10 20 30 40 50 60 70 Q [l/s]

0

5

10

15

20

25

30

[m]H

0

10

20

30

40

50

[ft]

NPSH

50H.S

60 Hz

ISO 9906 Annex A

S1.30.A40.147.4.

S1.30.A40.181.4.

S1.30.A40.134.4.

S1.30.A40.147.4.

S1.30.A40.181.4.

S1.30.A40.134.4.

0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

S1.30.A40.181.4.

S1.30.A40.134.4.

S1.30.A40.147.4.

Pump type:

50: Range 50H: Pressure range (High pressure)S: Installation type

Total pump head H = Htotal

QH curve for the individual pump.

NPSH curves for each individual pump. When sizing the pumps, add a safety margin of at least 1.6 ft (0.5 m).

The power curves indicate shaft power [P2] for the pumps shown

Max. efficiency mark

Curve charts/Technical data

S pumps, range 50

Curve conditionsThe guidelines below apply to the curves shown in the performance charts on page 32 to page 44.

• ANSI-HI Centrifugal pump test 1.6-2000, Accep-tance level B.

• The curves show pump performance with different impeller diameters at rated speed.

• The bold part of the curves show the recom-mended operating range.

• The curves apply to the pumping of airless water at a temperature of 68 °F (+20 °C) and a kinematic vis-cosity of 1 cSt (1 mm2/s).

• NPSH: The curves show average values measured under the same conditions as the performance curves.When dimensioning the pump, add a safety margin of at least 1.6 ft (0.5 m).

• In case of other densities than 133.5 ounces/gallon (1000 kg/m3), the discharge pressure is proportional to the density.

• When pumping liquids with a density higher than 133.5 ounces/gallon (1000 kg/m3), motors with cor-respondingly higher outputs must be used.

Calculation of total headThe total pump head consists of the height difference between the measuring points + the differential head + the dynamic head.

Performance testsThe requested duty point for every pump is tested according to ISO 9906, Annex A, and without certifica-tion.

In case of pumps ordered on the basis of impeller diam-eter only (no requested duty point), the pump will be tested close to the best efficiency point (BEP) of the published performance curve which is related to the ordered impeller diameter (according to ISO 9906, Annex A).

If the customer requires either more points on the curve to be checked or certain minimum performances or cer-tificates, individual measurements must be made, and a certificate can be ordered.

CertificatesCertificates have to be confirmed for every order and are available on request as follows:

• Certificate of compliance with the order (EN 10204 - 2.1)

• Pump test sheet.

Witness testWhen the pumps are being tested or are tested with a certification it is possible for the customer to witness the testing procedure according to ISO 9906.

The witness test is not a certificate and will not result in a written statement from Grundfos. The witness itself is the only guarantee that everything is carried out as pre-scribed in the testing procedure.

If the customer wants to witness test the pump perfor-mance, place this request on the order.

Hgeo: Height difference between measuring points.

Hstat:Differential head between suction and the discharge side of the pump.

Hdyn: Calculated values based on the velocity of the pumped liquid on the suction and the discharge side of the pump.

Htotal Hgeo Hstat Hdyn+ +=

31

32

S pumps, range 50Performance curvesTechnical dataS 50 SuperVortex, 2-pole

SV.30.A30.139 and SV.30.A30.168

TM04

656

0 06

10

0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]

0

20

40

60

80

100

120

140

160

[ft]H

0 5 10 15 20 25 30 35 Q [l/s]

0

10

20

30

40

50

[m]H

0

10

20

30

40

[ft]NPSH

50H.S

60 Hz

ISO 9906 Annex A

SV.30.A30.139.2.

SV.30.A30.168.2.

SV.30.A30.168.2.

SV.30.A30.139.2.

0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

SV.30.A30.139.2.

SV.30.A30.168.2.

Performance curves Technical data

S pumps, range 50

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 )m cable

Pump type Voltage[V]

P1 [kw]

P2 [hp]

No. of poles RPM Con-

nection

FLA Istart hmotor [%] Cos φ Moment of inertia

[lbft2 (kgm2)]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

SV.30.A30.139.2.50H 3 x 460 13 13.9 2 3537 DOL 19 185 70 76 79 0.74 0.83 0.88 0.71 (0.03) 104.7 (142)SV.30.A30.139.2.50H 3 x 230 13 13.9 2 3537 DOL 38 370 70 76 79 0.74 0.83 0.88 0.71 (0.03) 104.7 (142)SV.30.A30.168.2.50H 3 x 460 16 16.8 2 3515 DOL 23 185 73 78 79 0.78 0.86 0.89 0.71 (0.03) 104.7 (142)SV.30.A30.168.2.50H 3 x 230 16 16.8 2 3515 DOL 45 370 73 78 79 0.78 0.86 0.89 0.71 (0.03) 104.7 (142)

Pump typeMax. solids size Max. installation depth Weight*

[inch (mm)] [feet (m)] [lbs (kg)]SV.30.A30.139.2.50H.S.159 3 (80) 65 (20) 375 (170)SV.30.A30.168.2.50H.S.172 3 (80) 65 (20) 419 (190)

33

Performance curves Technical data

S pumps, range 50

34

S 50 low pressure, 4-pole

S1.40.A50.134 and S1.40.A50.181

TM04

656

1 06

10TM

04 6

562

0610

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

[ft]H

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

[ft]

NPSH

50L.S

60 Hz

ISO 9906 Annex A

S1.40.A50.134.4.

S1.40.A50.181.4.

S1.40.A50.134.4.

S1.40.A50.181.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

S1.40.A50.134.4.

S1.40.A50.181.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

[ft]H

0 10 20 30 40 50 60 70 80 90 100 Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

50

[ft]NPSH

50L.C/H

60 Hz

ISO 9906 Annex A

S1.40.A50.134.4.

S1.40.A50.181.4.

S1.40.A50.134.4.

S1.40.A50.181.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

S1.40.A50.134.4.

S1.40.A50.181.4.

Performance curves Technical data

S pumps, range 50

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 )m cable

Pump type Voltage[V]

P1 [kw]

P2 [hp]

No. of poles RPM Con-

nection

FLA Istart hmotor [%] Cos φ Moment of inertia

[lbft2 (kgm2)]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S1.40.A50.134.4.50L 3 x 460 12 13.4 4 1728 DOL 18 113 78 81 80 0.72 0.82 0.88 0.55 (0.023) 99.6 (135)S1.40.A50.134.4.50L 3 x 230 12 13.4 4 1728 DOL 36 226 78 81 80 0.72 0.82 0.88 0.55 (0.023) 99.6 (135)S1.40.A50.181.4.50L 3 x 460 16 18.1 4 1747 DOL 23 125 82 85 85 0.69 0.81 0.87 0.95 (0 04) 154.1 (209)S1.40.A50.181.4.50L 3 x 230 16 18.1 4 1747 DOL 46 250 82 85 85 0.69 0.81 0.87 0.95 (0 04) 154.1 (209)

Pump typeMax. solids size Max. installation

depth Weight*

[inch (mm)] [feet (m)] [lbs (kg)]S1.40.A50.134.4.50L.S 4 (100) 65 (20) 551 (250)S1.40.A50.134.4.50L.C 4 (100) 65 (20) 595 (270)S1.40.A50.134.4.50L.H 4 (100) 65 (20) 694 (315)S1.40.A50.181.4.50L.S 4 (100) 65 (20) 551 (250)S1.40.A50.181.4.50L.C 4 (100) 65 (20) 595 (270)S1.40.A50.181.4.50L.H 4 (100) 65 (20) 694 (315)

35

Performance curves Technical data

S pumps, range 50

36

S 50 medium pressure, 4-pole

S1.40.A40.134 and S1.40.A40.181

TM04

656

3 06

10TM

04 6

564

0610

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0

10

20

30

40

50

60

70

80

[ft]H

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

50

[ft]NPSH

50M.S

60 Hz

ISO 9906 Annex A

S1.40.A40.134.4.

S1.40.A40.181.4.

S1.40.A40.134.4.

S1.40.A40.181.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

S1.40.A40.134.4.

S1.40.A40.181.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0

10

20

30

40

50

60

70

80

[ft]H

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

[ft]NPSH

50M.C/H

60 Hz

ISO 9906 Annex A

S1.40.A40.134.4.

S1.40.A40.181.4.

S1.40.A40.134.4.

S1.40.A40.181.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

S1.40.A40.134.4.

S1.40.A40.181.4.

Performance curves Technical data

S pumps, range 50

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 )m cable

Pump type Voltage[V]

P1 [kw]

P2 [hp]

No. of poles RPM Con-

nection

FLA Istart hmotor [%] Cos φ Moment of inertia

[lbft2 (kgm2)]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S1.40.A40.134.4.50M 3 x 460 12 13.4 4 1728 DOL 18 113 78 81 80 0.72 0.82 0.88 0 55 (0.023) 99.6 (135)S1.40.A40.134.4.50M 3 x 230 12 13.4 4 1728 DOL 36 226 78 81 80 0.72 0.82 0.88 0 55 (0.023) 99.6 (135)S1.40.A40.181.4.50M 3 x 460 16 18.1 4 1747 DOL 23 125 82 85 85 0.69 0.81 0.87 0 95 (0.04) 154.1 (209)S1.40.A40.181.4.50M 3 x 230 16 18.1 4 1747 DOL 46 250 82 85 85 0.69 0.81 0.87 0 95 (0.04) 154.1 (209)

Pump typeMax. solids size Max. installation

depth Weight*

[inch (mm)] [feet (m)] [lbs (kg)]S1.40.A40.134.4.50M.S 4 (100) 65 (20) 419 (190)S1.40.A40.134.4.50M.C 4 (100) 65 (20) 463 (210)S1.40.A40.134.4.50M.H 4 (100) 65 (20) 562 (255)S1.40.A40.181.4.50M.S 4 (100) 65 (20) 419 (190)S1.40.A40.181.4.50M.C 4 (100) 65 (20) 463 (210)S1.40.A40.181.4.50M.H 4 (100) 65 (20) 573 (260)

37

Performance curves Technical data

S pumps, range 50

38

S 50 high pressure, 4-pole

S1.30.A40.134, S1.30.A40.147 and S1.30.A40.181

TM04

655

8 06

10TM

04 6

559

0610

0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

100

[ft]H

0 10 20 30 40 50 60 70 Q [l/s]

0

5

10

15

20

25

30

[m]H

0

10

20

30

40

50

[ft]

NPSH

50H.S

60 Hz

ISO 9906 Annex A

S1.30.A40.147.4.

S1.30.A40.181.4.

S1.30.A40.134.4.

S1.30.A40.147.4.

S1.30.A40.181.4.

S1.30.A40.134.4.

0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

S1.30.A40.181.4.

S1.30.A40.134.4.

S1.30.A40.147.4.

0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

100

[ft]H

0 10 20 30 40 50 60 70 Q [l/s]

0

5

10

15

20

25

30

[m]H

0

10

20

30

40

50

[ft]

NPSH

50H.C/H

60 Hz

ISO 9906 Annex A

S1.30.A40.134.4.

S1.30.A40.147.4.

S1.30.A40.181.4.

S1.30.A40.181.4.

S1.30.A40.134.4.

S1.30.A40.147.4.

0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]

0

4

8

12

16

20

[hp]

P2

0

4

8

12

[kW]

P2

S1.30.A40.134.4.

S1.30.A40.147.4.

S1.30.A40.181.4.

Performance curves Technical data

S pumps, range 50

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 )m cable

Pump type Voltage[V]

P1 [kw]

P2 [hp]

No. of poles RPM Con-

nection

FLA Istart hmotor [%] Cos φ Moment of inertia

[lbft2 (kgm2)]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S1.30.A40.134.4.50H 3 x 460 12 13.4 4 1728 DOL 18 113 78 81 80 0.72 0.82 0.88 0.55 (0.023) 99.6 (135)S1.30.A40.134.4.50H 3 x 230 12 13.4 4 1728 DOL 36 226 78 81 80 0.72 0.82 0.88 0.55 (0.023) 99.6 (135)S1.30.A40.147.4.50H 3 x 460 13 14.7 4 1761 DOL 20 125 80 84 86 0.63 0.76 0.84 0.95 (0.04) 154.1 (209)S1.30.A40.147.4.50H 3 x 230 13 14.7 4 1761 DOL 39 250 80 84 86 0.63 0.76 0.84 0.95 (0.04) 154.1 (209)S1.30.A40.181.4.50H 3 x 460 16 18.1 4 1747 DOL 23 125 82 85 85 0.69 0.81 0.87 0.95 (0.04) 154.1 (209)S1.30.A40.181.4.50H 3 x 230 16 18.1 4 1747 DOL 46 250 82 85 85 0.69 0.81 0.87 0.95 (0.04) 154.1 (209)

Pump typeMax. solids size Max. installation

depth Weight*

[inch (mm)] [feet (m)] [lbs (kg)]S1.30.A40.134.4.50H.S 3 (80) 65 (20) 441 (200)S1.30.A40.134.4.50H.C 3 (80) 65 (20) 485 (220)S1.30.A40.134.4.50H.H 3 (80) 65 (20) 551 (250)S1.30.A40.134.4.50H.S 3 (80) 65 (20) 397 (180)S1.30.A40.134.4.50H.C 3 (80) 65 (20) 419 (190)S1.30.A40.134.4.50H.H 3 (80) 65 (20) 507 (230)S1.30.A40.147.4.50H.S 3 (80) 65 (20) 441 (200)S1.30.A40.147.4.50H.C 3 (80) 65 (20) 485 (220)S1.30.A40.147.4.50H.H 3 (80) 65 (20) 573 (260)S1.30.A40.181.4.50H.S 3 (80) 65 (20) 441 (200)S1.30.A40.181.4.50H.C 3 (80) 65 (20) 485 (220)S1.30.A40.181.4.50H.H 3 (80) 65 (20) 573 (260)

39

40

S pumps, range 50Accessories

Accessories (for installation)

Pump type Installation accessoriesS 50-70 S and C NPS 3-8 (DN 80-200) without guide claw (guide claw included in auto-coupling kit)S 50-70 S and C NPS 10-24 (DN 250-600) with guide claw mounted on the pumpS 50-70 D Pump without installation accessories (accessories as separate kit)S 50-70 H Base stand for horizontal, dry installation supplied together with the pump

Pictures Description Size Weight [lb (kg)] PN Product

numberG

R81

26

Cast-iron, epoxy-coated auto-coupling system complete with:• guide claw• base unit• upper guide rail bracket• gaskets and bolts.

Dis

char

ge fl

ange

NPS 4" (DN 100) 120 (54.45) 10 97626238

NPS 4" / NPS3"(DN 100 / DN 80)

126.9 (57.55) 10 97626239

NPS 5"/NPS 6"(DN 125/150)

229.28 (104) 10 97626242

Intermediate guide rail bracket For guide rails longer than 19.5 feet (6 m)

NPS 3" (DN 80) 96825142

NPS 4" (DN 100) 96825161

NPS 5" (DN 125) 96829331

Guide rails Standard pipes. Not supplied by Grundfos

TM02

885

6 09

04 -

TM02

885

7 09

04

Cast iron, epoxy-coated ring stand.Supplied with bolts, nuts, gaskets and anchor bolts.

Stand/pump discharge hose

NPS 4" / NPS3"(DN 100 / DN 80) 10 96844859

NPS 4" (DN 100) 10 96848863

NPS 4" (DN 100) 10 96848864

NPS 4" (DN 100) 10 96846769

TM04

403

5 05

09

Vertical base stand (without bend).

Suc

tion

flang

e

NPS 6" (DN150) 96308238

NPS 4" (DN 100) 96845469

TM04

415

6 09

09 Base stand for horizontal, dry installation.Supplied with bolts, gaskets and anchor bolts.Material:* = galvanised steel** = stainless steel

NPS 6" (DN150)

99.2 (45)* 96776517

99.2 (45)** 96844857

Accessories S pumps, range 50

Other accessoriesPictures Description Product number

TM02

612

6 51

0213 ft (4 m) galvanised lifting chain with lifting link and safety hook.With certificates.

Max. 1763 lb (800 kg) S 34-58

96735550

20 ft (6 m) galvanised lifting chain with lifting link and safety hook.With certificates. 96735553

26 ft (8 m) galvanised lifting chain with lifting link and safety hook.With certificates. 96735554

33 ft (10 m) galvanised lifting chain with lifting link and safety hook. With certificates. 96735556

40 ft (12 m) galvanised lifting chain with lifting link and safety hook.With certificates. 96735557

13 ft (4 m) stainless steel lifting chain with lifting link and safety hook.

Max. 1763 lb (800 kg) S 34-58

96735559

20 ft (6 m) stainless steel lifting chain with lifting link and safety hook. 96735564

26 ft (8 m) stainless steel lifting chain with lifting link and safety hook. 96735566

33 ft (10 m) stainless steel lifting chain with lifting link and safety hook. 96735567

40 ft (12 m) stainless steel lifting chain with lifting link and safety hook. 96735569

TM01

698

2 39

99 Float switch with 33 ft (10 m) cable 96003332

Float switch with 66 ft (20 m) cable 96003695

TM02

886

2 09

04

Bracket for two float switches 96003338

TM02

067

0 50

00

Float switches with bracket, 33 ft (10 m) cable

2 switches, 1 pump without alarm 62500013

3 switches, 1 pump with alarm 62500014

3 switches, 2 pumps with alarm 62500014

4 switches, 2 pumps with alarm 62500015

41

42

S pumps, range 50Dimensions

Installation on auto coupling

Fig.

17

Dim

ensi

onal

ske

tche

s, in

stal

latio

n on

aut

o-co

uplin

g sy

stem

Z12a

is m

inim

um re

com

men

ded

dist

ance

from

pit

botto

m to

bot

tom

of p

ump

suct

ion

side

.

Z11

is to

tal h

eigh

t of p

ump

inst

alle

d on

Gru

ndfo

s in

stal

latio

n ac

cess

ory

in th

e pi

t. N

OTE

: Thi

s fig

ure

mig

ht n

ot e

qual

Z12

a +

Z1.

Not

e:

TM04 2416 2508

Z17

G/S

Min

. lev

el,

nsta

llatio

n S

Min

. lev

el,

nsta

llatio

n C

Dimensions S pumps, range 50

S pu

mps

, ran

ge 5

0 [in

ch]

ZM

4 X

M16

4 X

M16

4 X

M16

4 X

M16

4 X

M16

4 X

M16

4 X

M16

ZL2

4.1

4.1

4.1

4.1

4.1

4.1

4.1

ZL1

17.2

17.2

17.2

17.2

17.2

17.2

17.2

ZDt1

0.9

0.9

0.9

0.9

0.9

0.9

0.9

ZDN

1

4" 4" 4" 4" 4" 4" 4"

ZDc1

7.1

7.1

7.1

7.1

7.1

7.1

7.1

Z17 S 0.

10.

10.

10.

10.

10.

10.

1

G 0.1

0.1

0.1

0.1

0.1

0.1

0.1

Z16

16.3

16.3

16.3

16.3

16.3

16.3

16.3

Z15

8.7

8.7

8.7

8.7

8.7

8.7

8.7

Z14 - - - - - - -

Z13 - - 2.0

2.0

2.0

2.0

2.0

Z12b

9.4

9.4

9.4

9.4

9.4

9.4

9.4

Z12a

3.2

3.2

5.1

5.1

5.1

5.3

5.3

Z11

40.0

40.0

43.3

43.3

43.3

44.3

44.3

Z10

2.4

2.4

2.4

2.4

2.4

2.4

2.4

Z9 4.3

4.3

4.3

4.3

4.3

4.3

4.3

Z8 24.1

24.1

19.6

19.6

19.6

20.7

20.7

Z7 31.1

31.1

26.7

26.7

26.7

27.6

27.6

Z6 40.0

40.0

35.5

35.5

35.5

36.5

36.5

Z4 8.7

8.7

8.7

8.7

8.7

8.7

8.7

Z3 4.3

4.3

4.3

4.3

4.3

4.3

4.3

Z2 10.2

10.2

10.2

10.2

10.2

10.2

10.2

Z1 36.8

36.8

38.2

38.2

38.2

39.0

39.0

ZØ1

8 X

20

8 X

20

8 X

20

8 X

20

8 X

20

8 X

20

8 X

20

F

14.0

14.0

14.6

14.6

14.6

14.7

14.7

C 22.8

22.8

18.3

18.3

18.3

19.3

19.3

Pum

p ty

pe

SV.

30.A

30.1

39.2

.50H

SV.

30.A

30.1

68.2

.50H

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

S pu

mps

, ran

ge 5

0 [m

m]

ZM

4 X

M16

4 X

M16

4 X

M16

4 X

M16

4 X

M16

4 X

M16

4 X

M16

ZL2

103

103

103

103

103

103

103

ZL1

438

438

438

438

438

438

438

ZDt1

22 22 22 22 22 22 22

ZDN

1

4" 4" 4" 4" 4" 4" 4"

ZDc1

180

180

180

180

180

180

180

Z17 S 3.

03.

03.

03.

03.

03.

03.

0

G 3.0

3.0

3.0

3.0

3.0

3.0

3.0

Z16

413

413

413

413

413

413

413

Z15

220

220

220

220

220

220

220

Z14 - - - - - - -

Z13 - - 50 50 50 50 50

Z12b

240

240

240

240

240

240

240

Z12a 82 82 130

130

130

134

134

Z11

1017

1017

1101

1101

1101

1124

1124

Z10

60.3

60.3

60.3

60.3

60.3

60.3

60.3

Z9 110

110

110

110

110

110

110

Z8 613

613

498

498

498

525

525

Z7 791

791

677

677

677

702

702

Z6

1.01

61.

016

902

902

902

927

927

Z4 220

220

220

220

220

220

220

Z3 110

110

110

110

110

110

110

Z2 260

260

260

260

260

260

260

Z1 935

935

971

971

971

990

990

ZØ1

8 X

20

8 X

20

8 X

20

8 X

20

8 X

20

8 X

20

8 X

20

F 356

356

371

371

371

373

373

C 578

578

464

464

464

489

489

Pum

p ty

pe

SV.

30.A

30.1

39.2

.50H

SV.

30.A

30.1

68.2

.50H

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

43

Dimensions S pumps, range 50

44

Fig.

18

Dim

ensi

onal

ske

tche

s, in

stal

latio

n on

aut

o-co

uplin

g sy

stem

(2)

Z12a

is m

inim

um re

com

men

ded

dist

ance

from

pit

botto

m to

bot

tom

of p

ump

suct

ion

side

.

Z11

is to

tal h

eigh

t of p

ump

inst

alle

d on

Gru

ndfo

s in

stal

latio

n ac

cess

ory

in th

e pi

t. N

OTE

: Thi

s fig

ure

mig

ht n

ot e

qual

Z12

a +

Z1.

Not

e:

TM04 2417 2508

Z14

Z17

G/S

Min

. lev

el,

nsta

llatio

n S

Min

. lev

el,

nsta

llatio

n C

Dimensions S pumps, range 50

S pu

mps

, ran

ge 5

0 [in

ch]

ZM

4XM

164X

M16

ZL2

5.8

5.8

ZL1

22.5

22.5

ZDt1

1.0

1.0

ZDN

1

6"

6"

ZDc1

9.4

9.4

Z17 S 0.

10.

1

G 0.1

0.1

Z16

22.6

22.6

Z15

11.0

11.0

Z14 - -

Z13 - -

Z12b

15.7

15.7

Z12a

3.9

3.9

Z11

47.9

47.9

Z10

3.5

3.5

Z9 4.3

4.3

Z8 25.1

25.1

Z7 33.3

33.3

Z6 45.6

45.6

Z4 11.0

11.0

Z3 4.8

4.8

Z2 11.8

11.8

Z1 38.6

38.6

ZØ1

8X23

8X23

F

16.9

16.9

C 23.1

23.1

Pum

p ty

pe

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

S pu

mps

, ran

ge 5

0 [m

m]

ZM

4XM

164X

M16

ZL2

147

147

ZL1

571

571

ZDt1

25 25

ZDN

1

6"

6"

ZDc1

240

240

Z17 S 3.

03.

0

G 3.0

3.0

Z16

575

575

Z15

280

280

Z14 - -

Z13 - -

Z12b

400

400

Z12a

100

100

Z11

1217

1217

Z10

88.0

88.0

Z9 110

110

Z8 637

637

Z7 845

845

Z6 1159

1159

Z4 280

280

Z3 123

123

Z2 300

300

Z1 981

981

ZØ1

8X23

8X23

F 430

430

C 588

588

Pum

p ty

pe

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

45

Dimensions S pumps, range 50

46

Installation on ring stand

Fig.

19

Dim

ensi

onal

ske

tch,

inst

alla

tion

on ri

ng s

tand

TM04 2419 2508

HC

L

Dimensions S pumps, range 50

S pu

mps

, ran

ge 5

0 [in

ch]

F

14.0

14.0

14.6

14.6

14.6

14.7

14.7

16.9

16.9

D 7.0

7.0

7.3

7.3

7.3

7.3

7.3

9.5

9.5

DST

H

5.1

5.1

3.8

3.8

3.8

7.3

7.3

7.3

7.3

HC

L

4.6

4.6

5.4

5.4

5.4

5.6

5.6

11.4

11.4

HC

H

5.6

5.6

7.0

7.0

7.0

5.7

5.7

11.0

11.0

Y5 12.2

12.2

12.2

12.2

12.2

17.7

17.7

17.7

17.7

Y4 26.5

26.5

22.7

22.7

22.7

26.7

26.7

35.2

35.2

Y3

16.9

16.9

17.0

17.0

17.0

19.2

19.2

24.8

24.8

Y2 11.3

11.3

10.1

10.1

10.1

13.5

13.5

13.8

13.8

Y1 41.9

41.9

42.0

42.0

42.0

46.3

46.3

45.9

45.9

Y Ø

2

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

Pum

p ty

pe

SV.

30.A

30.1

39.2

.50H

SV.

30.A

30.1

68.2

.50H

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

S pu

mps

, ran

ge 5

0 [m

m]

F 356

356

371

371

371

373

373

430

430

D 178

178

185

185

185

186

186

241

241

DST

H

130

130

96 96 96 186

186

186

186

HC

L

118

118

136

136

136

142

142

289

289

HC

H

142

142

177

177

177

145

145

280

280

Y5 310

310

310

310

310

450

450

450

450

Y4 673

673

576

576

576

679

679

894

894

Y3 430

430

433

433

433

487

487

630

630

Y2 288

288

256

256

256

342

342

350

350

Y1 1065

1065

1067

1067

1067

1176

1176

1167

1167

Y Ø

2

3 3 4 4 4 4 4 6 6

Pum

p ty

pe

SV.

30.A

30.1

39.2

.50H

SV.

30.A

30.1

68.2

.50H

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

47

Dimensions S pumps, range 50

48

Dry-pit, vertical installation

Fig.

20

Dim

ensi

onal

ske

tch,

dry

, ver

tical

inst

alla

tion

TM04 2421 2508/TM04 2422 2508

X13

X13

1

Dimensions S pumps, range 50

S pu

mps

, ran

ge 5

0 [in

ch]

XM1

M20

X3

M20

X3

M20

X3

M20

X6

M20

X6

M20

X6

M20

X6

Dt2 0.8

0.8

0.8

0.9

0.9

1.0

1.0

XDt1

0.9

0.9

0.9

0.9

0.9

0.9

0.9

XDc3

7.5

7.5

7.5

9.4

9.4

9.4

9.4

X17

23.7

23.7

23.7

30.6

30.6

30.9

30.9

X16

55.7

55.7

55.7

63.4

63.4

63.1

63.1

X15

18.4

18.4

18.4

20.5

20.5

20.5

20.5

X14

5.9

5.9

5.9

6.4

6.4

9.1

9.1

X132 - - - 4.7

4.7

4.7

4.7

X131

5.3

5.3

5.3

5.9

5.9

5.9

5.9

X13

15.9

15.9

15.9

17.7

17.7

17.7

17.7

X6 17.4

17.4

17.4

24.4

24.4

24.4

24.4

X5 7.0

7.0

7.0

11.7

11.7

11.7

11.7

X4 9.8

9.8

9.8

11.8

11.8

11.8

11.8

XØ5

0.9

0.9

0.9

0.9

0.9

0.9

0.9

XØ3

0.7

0.7

0.7

0.9

0.9

0.9

0.9

F

14.6

14.6

14.6

14.7

14.7

16.9

16.9

E 11.2

11.2

11.2

12.3

12.3

15.0

15.0

C 18.3

18.3

18.3

19.3

19.3

23.1

23.1

Pum

p ty

pe

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

S pu

mps

, ran

ge 5

0 [m

m]

XM1

M20

X3

M20

X3

M20

X3

M20

X6

M20

X6

M20

X6

M20

X6

Dt2 20 20 20 22 22 25 25

XDt1

22 22 22 24 24 24 24

XDc3

191

191

191

240

240

240

240

X17

603

603

603

777

777

785

785

X16

1.41

41.

414

1.41

41.

611

1.61

11.

602

1.60

2

X15

468

468

468

520

520

520

520

X14

150

150

150

162

162

230

230

X132 - - -

120

120

120

120

X131

135

135

135

150

150

150

150

X13

405

405

405

450

450

450

450

X6 443

443

443

621

621

621

621

X5 177

177

177

296

296

296

296

X4 250

250

250

300

300

300

300

XØ5

24 24 24 24 24 24 24

XØ3

19 19 19 24 24 24 24

F 371

371

371

373

373

430

430

E 285

285

285

312

312

380

380

C 464

464

464

489

489

588

588

Pum

p ty

pe

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

49

Dimensions S pumps, range 50

50

Dry-pit, horisontal installation

Fig.

21

Dim

ensi

onal

ske

tch,

dry

, hor

ison

tal i

nsta

llatio

n

TM04 2413 2508

QZ1

QZ1

Dimensions S pumps, range 50

S pu

mps

, ran

ge 5

0 [in

ch]

Dt2 0.8

0.8

0.8

0.8

0.9

0.9

1.0

1.0

Dc2 7.5

7.5

7.5

7.5

7.5

7.5

8.5

8.5

2

0.7

0.7

0.7

0.7

0.7

0.7

0.9

0.9

D2N 8 8 8 8 8 8 8 8

QZ1 0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

1

M16

M16

M16

M16

M20

M20

M20

M20

QD

N1

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

QD

c1

7.5

7.5

7.5

7.5

9.4

9.4

9.4

9.4

Q10

32.1

32.1

32.1

32.1

32.1

32.1

32.1

32.1

Q8

15.4

15.4

15.4

15.4

15.4

15.4

15.4

15.4

Q6

19.7

19.7

19.7

19.7

19.7

19.7

19.7

19.7

Q5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

Q4

11.8

11.8

11.8

11.8

11.8

11.8

11.8

11.8

Q3

23.0

23.0

23.0

23.0

24.1

24.1

26.8

26.8

Q2

7.0

7.0

7.0

7.0

6.9

6.9

7.2

7.2

Q1

38.9

38.9

38.9

38.9

39.7

39.7

39.3

39.3

3

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

F

14.6

14.6

14.6

14.6

14.7

14.7

16.9

16.9

D 7.3

7.3

7.3

7.3

7.3

7.3

9.5

9.5

Pum

p ty

pe

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

S pu

mps

, ran

ge 5

0 [m

m]

Dt2 20 20 20 20 22 22 25 25

Dc2 191

191

191

191

191

191

216

216

2

19 19 19 19 19 19 22 22

D2N 8 8 8 8 8 8 8 8

QZ1 18 18 18 18 18 18 18 18

1

M16

M16

M16

M16

M20

M20

M20

M20

QD

N1

8 8 8 8 8 8 8 8

QD

c1

191

191

191

191

240

240

240

240

Q10

815

815

815

815

815

815

815

815

Q8

390

390

390

390

390

390

390

390

Q6

500

500

500

500

500

500

500

500

Q5

115

115

115

115

115

115

115

115

Q4

300

300

300

300

300

300

300

300

Q3

585

585

585

585

612

612

680

680

Q2

178

178

178

178

174

174

182

182

Q1

989

989

989

989

1008

1008

999

999

3

18 18 18 18 18 18 18 18

F 371

371

371

371

373

373

430

430

D 185

185

185

185

186

186

241

241

Pum

p ty

pe

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

34.4

.50H

S1.

30.A

40.1

47.4

.50H

S1.

30.A

40.1

81.4

.50H

S1.

40.A

40.1

34.4

.50M

S1.

40.A

40.1

81.4

.50M

S1.

40.A

50.1

34.4

.50L

S1.

40.A

50.1

81.4

.50L

51

52

S pumps, range 50Further product documentation

WebCAPSWebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.

WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages.

In WebCAPS, all information is divided into 6 sections:

• Catalogue• Literature• Service• Sizing• Replacement• CAD drawings.

Catalogue

This section is based on fields of application and pump types, and contains • technical data• curves (QH, Eta, P1, P2, etc) which can be adapted to the den-

sity and viscosity of the pumped liquid and show the number of pumps in operation

• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.

Literature

In this section you can access all the latest documents of a given pump, such as• data booklets• installation and operating instructions• service documentation, such as Service kit catalogue and Serv-

ice kit instructions• quick guides• product brochures, etc.

Service

This section contains an easy-to-use interactive service cata-logue. Here you can find and identify service parts of both exist-ing and discontinued Grundfos pumps.Furthermore, this section contains service videos showing you how to replace service parts.

Further product documentation

S pumps, range 50

WinCAPS

Fig. 22 WinCAPS CD-ROM

WinCAPS is a Windows-based Computer Aided Prod-uct Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages.

The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet con-nection is available.

WinCAPS is available on CD-ROM and updated once a year.

Sizing

This section is based on different fields of application and installa-tion examples, and gives easy step-by-step instructions in how to• select the most suitable and efficient pump for your installation• carry out advanced calculations based on energy consumption,

payback periods, load profiles, life cycle costs, etc.• analyse your selected pump via the built-in life cycle cost tool• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing re-placement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grund-fos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:• .dxf, wireframe drawings• .dwg, wireframe drawings.

3-dimensional drawings:• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.

0 1

Subject to alterations.

53

S pumps, range 50

54

S pumps, range 50

55

www.yccpump.com

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence

YEOMANS CHICAGO Corporation3905 Enterprise CourtP.O. Box 6620Aurora, IL 60598-0620PH: 630-236-5500 FX: 630-236-5511