Date post: | 28-Dec-2015 |
Category: |
Documents |
Upload: | merry-pope |
View: | 217 times |
Download: | 1 times |
SS SS RR CC
O. Evdokov, B. Pirogov, B. Tolochko, I. Zhogin
Institute of Solid State Chemistry and Mechanochemistry
N. Gavrilov, A. Kosov, M. Sheromov, V. Tsukanov
Budker Institute of Nuclear Physics
A. Shmakov
Boreskov Institute of Catalysis
Compact Wave Strain-Friction Compact Wave Strain-Friction
reducers (0.3"–1.5" mini-reducers (0.3"–1.5" mini-
goniometers) for X-ray optics goniometers) for X-ray optics
at Siberian SR Centerat Siberian SR Center
OutlineOutline
• Introduction: the problem of precision rotation feedthrough into high vacuum and basics of Wave Strain-Friction (WSF) drive
• Design: WSF-reducers in drawings and in reality -- vacuum (CF63) and non-vacuum versions
• Parameters: testing WSF-reducers with encoder LIR-1170A (accuracy of 0.1 mdeg, or 0.36 arc sec)
• Applications: (1) single-crystal high-vacuum drum-type monochromator (where fast change of crystals is possible); (2) double-crystal high-vacuum fixed-exit monochromator
• Conclusion and Acknowledgments
IntroductionIntroduction• Feedthrough of precision motion (rotation) into high vacuum
is a difficult problem (high vacuum mechanics is expensive)
a) viton sealing and differential pumpingb) piezoceramicsc) strain & friction mechanics – most simple
way (N Gavrilov)
• ABC of Wave Strain-Friction (WSF) drive
Outer rigid ring
Inner flexible ring
Wave generator
Elasticdeformations,
D – inner diameter of outer ringd – outer diameter of inner ringk – coefficient of reduction – elastic deformations
k
k0
DesignDesign WSF-reducers in drawings: vacuum (CF63)
and non-vacuum versions
stepperstepper
… and in reality
Parameters
Parameters
Testing WSF-reducers with encoder LIR-1170A
encoder
stepper0.9° (0.45°)
period ~ 650 h-stepsh-step ~ 0.32”±0.35”
period ~ 800/3 h-steps
period ~650 stepsstep ~ 0.33”
vacuum variant
Applications
Applications Single-crystal high-vacuum drum-type monochromator (design: E.I. Pokhlebenin )
Ion chamber
Monochromator
2 = 30°
Si 111 – 7.64 keV
Si 220 – 12.47 keV
Single-crystal high-vacuum drum-type monochromator installed on 6-th beam-line
Ion chamber Monochromator
Applications
Applications Double-crystal high-vacuum fixed-exit monochromator(design: N.G. Gavrilov, I.L. Zhogin)
C1 - the first crystal; C2 - the second crystal (Si 111 or 311)
3 - horizontal (Huber) stage (working range of ~190 mm)
4 - bellows; 5 - plunger-rod (with tubes for water cooling of the first crystal); beam offset is h=40 mm; range of energy (Si111) 5–19 keV;
L1, L2 - levers clamping to their rollers R1 and R2; Li-lever rotates Ci-crystal
SRI-03 proc., p. 691
Fine (de)tuning of the first crystal
10 20 300
2
4
6
8
(V1+
V2)/
I VE
PP
time, s (x 50 steps/s)-15 -10 -5 0 5 10 150
1
2
3
4
5Correlation of 2 rock.curves (autocorrelation)
, arc.sec.
E=11 keV, Si111”
Correlation of two rock.curves(autocorrelation; XOP)
1 h-step ~ 0.03”
(DShI-200
200 steps/rot.)
time, s (x 50 half-step/s)
ConclusionConclusion
• WSF-reducers are a good choice (compact and inexpensive) for a feedthrough of precision rotary motion into high vacuum (or other environment)
• their performance can be improved by increasing the diameters of rings (and with better manufacturing)
• to be continued later