PUMP SPECIFICATIONS SERIES/MODEL GPM (LITERS) DISPLACEMENT CUBIC IN (CC) WT.** LBS (KG) MAX* RPM MIN* RPM MAX* PRES PSI (BAR) INLET N.P.T. PORT CYLINDER N.P.T. PORT RETURN N.P.T. PORT 6 1.47 (24) 32 (14.8) 2500 800 3000 (207)** 1-1/4 IN. 3/4 IN. 3/4 IN. 11 2.96 (48.5) 35 (15.9) 2500 800 3000 (307)** 1-1/4 IN. 3/4 IN. 3/4 IN. 15 3.94 (65) 38 (17.2) 2500 800 2500 (172) 1-1/4 IN. 3/4 IN. 3/4 IN. ** Requires high pressure relief PS1-1231VH for settings above 2500 PSI. 6, 11, & 15 GPM Sizes PTO Direct Mount or Twin Shaft Remote Single Acting Pressures to 3000 PSI (207 Bar) Speeds to 2500 Rpm Integral Valve for 2 or 3 Line System Anti Pull Out Safety Cap Built in Screw Adjust Relief Valve With Load Check Long Assembly Studs for Support Brackets Port I.D. Cap Plugs and Casting Stamp Optional Air or Cable Shifting Interchanges with Parker, Permco, and others S SERIES HOIST PUMPS The Muncie S Series hoist pump was designed specifically for use on small single or tandem axle dump trucks. The S Series hoist pump can be air, lever, or cable shifted. Options for both remote and direct mounting styles make the S Series pump adaptable to almost any small dump truck application. 3-LINE HOIST SYSTEM Many small hoists function quite adequately with a 2-line system. However, a 3-line system includes a separate line to return hydraulic oil from the cylinder directly to the reservoir instead of forcing its way back through the inlet line. The separate 3rd line is the best choice because the 3-line allows faster down cycles and ultimately runs cooler. KEY FEATURES OPTIMAL CONTROL IN A SMALL PACKAGE
Transcript
Page 1: S SERIES - Muncie Power Products · 2015-04-28 · S SERIES HOIST PUMPS The Muncie S Series hoist pump was designed specifically for use on small single or tandem axle dump trucks.

PUMP SPECIFICATIONS

SERIES/MODEL

GPM (LITERS)

DISPLACEMENT

CUBIC IN (CC)

WT.**

LBS (KG)

MAX*

RPM

MIN*

RPM

MAX* PRES

PSI (BAR)

INLET

N.P.T. PORT

CYLINDER

N.P.T. PORT

RETURN

N.P.T. PORT

6 1.47 (24) 32 (14.8) 2500 800 3000 (207)** 1-1/4 IN. 3/4 IN. 3/4 IN.

11 2.96 (48.5) 35 (15.9) 2500 800 3000 (307)** 1-1/4 IN. 3/4 IN. 3/4 IN.

15 3.94 (65) 38 (17.2) 2500 800 2500 (172) 1-1/4 IN. 3/4 IN. 3/4 IN.

** Requires high pressure relief PS1-1231VH for settings above 2500 PSI.

• 6, 11, & 15 GPM Sizes

• PTO Direct Mount or Twin Shaft Remote

• Single Acting

• Pressures to 3000 PSI (207 Bar)

• Speeds to 2500 Rpm

• Integral Valve for 2 or 3 Line System

• Anti Pull Out Safety Cap

• Built in Screw Adjust Relief Valve With Load Check

• Long Assembly Studs for Support Brackets

• Port I.D. Cap Plugs and Casting Stamp

• Optional Air or Cable Shifting

• Interchanges with Parker, Permco, and others

S SERIESH O I S T P U M P S

The Muncie S Series hoist pump was designed

specifically for use on small single or tandem axle

dump trucks. The S Series hoist pump can be air, lever,

or cable shifted. Options for both remote and direct

mounting styles make the S Series pump adaptable to

almost any small dump truck application.

3-LINE HOIST SYSTEMMany small hoists function quite adequately with a 2-line system. However, a 3-line system includes a separate line to return hydraulic oil from the cylinder directly to the reservoir instead of forcing its way back through the inlet line.

The separate 3rd line is the best choice because the 3-line allows faster down cycles and ultimately runs cooler.

KEY FEATURES

OPTIMAL CONTROLIN A SMALL PACKAGE

Page 2: S SERIES - Muncie Power Products · 2015-04-28 · S SERIES HOIST PUMPS The Muncie S Series hoist pump was designed specifically for use on small single or tandem axle dump trucks.

OVERALL LENGTHS

PUMPSIZE

DIM AIN (MM)

DIM B1IN (MM)

DIM B2IN (MM)

WEIGHTLB (KG)

06 1.50 (38.1) 11.32 (287.5) 12.12 (307.8) 32 (14.8)

11 2.25 (57.2) 12.07 (306.6) 12.88 (327.2) 35 (15.9)

15 2.75 (69.9) 12.57 (319.3) 13.38 (339.9) 38 (17.2)

MOUNTING DIMENSION SINGLE ACTING

3.35[85.1]

3.15[80.1]

0.319 [8.10]0.312 [7.92]DIA. PINEYEBOTH ENDS

0.74[18.7]

PRESET AT2000 PSI +/- 100 PSI++

1/2”-13UNC = 28 THD X 1.00 [25.4] DEEP2 HOLES AS SHOWN.

3.12[79.2]

0.25[6.4]

0.88[22.3]

1.75[44.5]

RAIS

ENE

UTRA

LLO

WER

0.63[15.9]

0.41[10.4]

0.41[10.4]

4.16[105.6]

3.15[80.1] 0.319 [8.10]

0.312 [7.92]DIA. PINEYEBOTH ENDS

0.74[18.7]

RAIS

ENE

UTRA

LLO

WER

0.41[10.4]

0.41[10.4]

0.63[15.9]

4.000 [101.60]

3.996 [101.5]PILOT DIA.

Notes: DO NOT USE TEFLON TAPE ON PORTS. Optional Air Shift Cylinder (ACM-400 or 402). Optional Conversion Sleeve for 3-Line Hookup – Muncie Part No. AA1257. Tank return line must be below oil level at all times. Maximum inlet vacuum is 5 in. hg. (.17 BAR).

3/4” N.P.T.(RETURN)

5.95[151.2]

5.35[136.0]1.75

[44.5]

1.75[44.5]

2.68[68.0]

3/4” N.P.T.(CYLINDER)

1.93[49.1]

3.96 [100.6]

6.32 [160.6]

1.71[29.7]

0.91[23.1]

1-1/4” N.P.T.(INLET)

1.94[49.3]

1.81[46.0]

4.31[109.5]

2.33[59.1]

SHAFT

SHAFT

INLETPORT

1.00[25.4]

0.41[10.4] 0.94

[23.9]

1.25[31.8]

0.06[1.5]

0.12[3.0]

1.10[28.0]

1.0[25.4]

A

B1

2.33[59.1]

4.31[109.5]

2.94[74.7]

1.62[41.1]

2.05[52.1] DIA.

0.38[9.7]

0.50[12.8]

A

B2

Page 3: S SERIES - Muncie Power Products · 2015-04-28 · S SERIES HOIST PUMPS The Muncie S Series hoist pump was designed specifically for use on small single or tandem axle dump trucks.

PUMP SERIES SHOISTS/PORTING

Single Acting, No Sleeve 2Single Acting, With Sleeve 3

LEVER SHIFT LAIR SHIFT ADETENT DSPRING RETURN SDESIGN NO.

1

GPM (LPM) @ 1000 RPM 06 (23) (Actual Flows @ 2000 PSI (138 BAR) 11 (42)

15 (57) SHAFT SIZE & TYPE

1” Rd. w/1⁄4” St. Key (25.4 w/6.35 Key) 01 7⁄8” – 13 Tooth Splined 02

MODEL NUMBER CONSTRUCTIONS 2 L D 1 – 06 – 01 R P R B

ROTATIONB—Bi-Rotation (01, R mount only)L—Counter Clockwise R—Clockwise (B mount only)

PORT LOCATIONR—Rear

PORT TYPEP—Pipe Thread

TYPE OF MOUNTINGB—SAE “B” – 4-BoltR—Remote

Muncie does not promote specific manufacturers’ brands of oil. Recommendations below are guidelines; consult oil manufacturer for exact application needs.

Viscosity Range: Pour Point: 15°F (-10°C) Maximum Viscosity Minimum: 50-60 SUS (7.5-10.5 cST) Foam Resistance: Recommended Viscosity Optimum Continuous: 60-100 SUS (10.5-21.6 cST) Rust Resistance Inhibitors: Recommended Viscosity Maximum @ Startup: 7500 SUS (1600 cST) Corrosion Resistance: Recommended Viscosity Index: 90 Minimum Oxidation Stability: RecommendedAniline Point: 175 Minimum Anti-Wear Additive: .06% Zinc Minimum*

Note: Cold weather operation requires special oil considerations. Viscosity should not exceed 7500 SUS (1600 cST) at lowest startup temperature. Continuous operation should range between 60-1000 SUS (10.5-216 cST) for all temperature ranges. Never use diesel fuel or kerosene to thin oil.

*Anti-Wear Additives may be recommmeded by some motor manufacturers. However, they are optional and typically not required for gear pump or gear motors.

OIL RECOMMENDATIONS

Page 4: S SERIES - Muncie Power Products · 2015-04-28 · S SERIES HOIST PUMPS The Muncie S Series hoist pump was designed specifically for use on small single or tandem axle dump trucks.

Specif icat ions are subject to change without not ice. Al l r ights reserved.Please check www.munciepower.com for warrant ies and current versions of l i terature.

MP15-10 (Rev. 12-14)

Muncie Power Products, Inc., Member of Interpump Group201 East Jackson Street, Muncie, Indiana, USA 473051-800-367-7867


Recommended