30).
SDI DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS (PUBLICATION No.
AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, ALLOWABLE STRESS DESIGN.
ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY.
2018 NORTH CAROLINA STATE BUILDING CODE.
DESIGN CODES:
AND GENERAL NOTES SUCH AS 'DIMENSIONS CORRECTED' ARE NOT ACCEPTABLE.
AND DESCRIPTIONS OF ALL CHANGES MADE FROM PREVIOUS SUBMITTAL. LIST SHALL BE SPECIFIC
6. ALL SHOP DRAWING RESUBMITTALS SHALL INCLUDE A WRITTEN DETAILED LIST OF LOCATIONS
APPROVAL.
ALL PERSONNEL DEEMED NECESSARY BY CONTRACTOR PRIOR TO SUBMITTAL TO ENGINEER FOR
5. ALL STRUCTURAL SHOP DRAWINGS TO BE REVIEWED BY JOB SUPERINTENDENT IN ADDITION TO
EXPENSE OF THE CONTRACTOR.
ADDITIONAL OBSERVATIONS DUE TO THE DEFICIENCIES IN WORK OBSERVED WILL BE AT THE
4. ADDITIONAL OBSERVATIONS AS A RESULT OF REJECTION OF WORK COMPLETED AND/OR
TEMPORARY BRACING (AND ACCOMPANYING FOOTINGS), GUYS OR TIEDOWNS.
DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION
3. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS
BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK.
DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER
2. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD AND WITH ALL OTHER
DRAWINGS.
DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT THESE
1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND
GENERAL NOTES:
STRUCTURAL NOTES
PERMANENTLY EXPOSED TO EXTERIOR.
SHALL BE A36 THREADED ROD. PROVIDE HOT DIP GALVANIZE FINISH ON ALL ANCHOR BOLTS
ANCHOR BOLTS:
MANUFACTURER'S REPRESENTATIVE.
ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. INSTALLERS SHALL BE TRAINED BY THE
SIKA "SIKADUR INJECTION SEL", "HILTI-HIGH STRENGTH EPOXY", OR APPROVED EQUAL, INSTALLED IN
SHALL BE A POLYMER INJECTION SYSTEM SUCH AS RAMSET "EPCON", MOLLY "PARAMOUNT HVC",
CHEMICAL ANCHORS:
LOCATIONS AND SIZES SHALL BE APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
OR 6" CLEAR BETWEEN SLEEVES, WHICHEVER IS GREATER. PRIOR TO CONSTRUCTION SLEEVE
MINIMUM SLEEVE SPACING SHALL BE TWO DIAMETERS CENTER TO CENTER TO THE LARGER SLEEVE
PLUMBING SLEEVES:
ON GRANULAR ENGINEERED FILL MATERIAL.
REPORT FOR ALL REQUIREMENTS RELATED TO THE CONSTRUCTION OF THE SLAB AND FOOTINGS
3. DESIGNS BASED UPON AN ALLOWABLE BEARING CAPACITY OF 2,000 psf. SEE GEOTECHNICAL
CODES SECTION OF THESE STRUCTURAL NOTES.
REPORT FOR THE LOADS PRESCRIBED BY THE BUILDING CODE REFERENCED IN THE DESIGN
DESIGNS WERE BASED UPON STAYING WITHIN THE LIMITS GIVEN WITHIN THE GEOTECHNICAL
BUILDING TYPE IS THE RESPONSIBILITY OF THE GEOTECHNICAL ENGINEER. ALL STRUCTURAL
CONSTRUCTION DOCUMENTS. DETERMINING THE AMOUNT OF SETTLEMENT ACCEPTABLE FOR THE
SPECIFIC BUILDING TYPE, CONSTRUCTION TYPE, AND LIKELY LOADS SHOWN ON THE
2. GEOTECHNICAL RECOMMENDATIONS WERE PREPARED WITH SPECIFIC KNOWLEDGE OF THE
JULY 28, 2020DATE:-
ECS PROJECT No. 22:29313
MOREHEAD CITY, CARTERET COUNTY, NORTH CAROLINA
MOREHEAD CITY COUNTRY CLUB
GEOTECHNICAL ENGINEERING REPORTTITLE:-
PREPARED BY: ECS SOUTHEAST, LLP-
FOLLOWING:
INSTALLATION PROCEDURES. SITE PREPARATION AND FOUNDATION SHALL COMPLY WITH THE
1. SEE THE FOLLOWING REPORT FOR COMPLETE GEOTECHNICAL RECOMMENDATIONS AND
FOUNDATIONS:
REQUIREMENTS SET FORTH IN ACI STANDARDS 301 AND 347.
REMOVAL OF ALL FORMWORK, SHORES AND RESHORES SHALL MEET THE
LEAST TWO-THIRDS OF THE 28 DAY DESIGN STRENGTH. DESIGN, ERECTION AND
NO STRUCTURAL CONCRETE SHALL BE STRIPPED UNTIL IT HAS REACHED AT
FORMWORK AND SHORING:
DISCRETION.
ADDITIONAL #4 & #5 REINFORCING STEEL TO BE USED AT ENGINEER'S
12. CONTRACTOR TO FURNISH AND INSTALL 500 LINEAR FT. EACH OF
(CURRENT EDITIONS), RESPECTIVELY, SHALL BE MAINTAINED.
11. COLD WEATHER AND HOT WEATHER PROVISIONS OF ACI 306 AND 305
ENGINEER FOR ALL OPENINGS GREATER THAN 12"x12" FOR DESIGN.
EXTEND REINFORCING 2'-0" BEYOND OPENING IN BOTH DIRECTIONS. CONTACT
AROUND ALL OPENINGS GREATER THAN 12"x12" IN CAST-IN-PLACE CONCRETE.
10. PROVIDE TWO (2) #5'S, ONE AT EACH FACE, UNLESS NOTED OTHERWISE,
1 1/2"BEAMS AND COLUMNS
1 1/2"#14 AND #18
3/4"#11 BARS OR SMALLER
AND WALLS
OR IN CONTACT WITH THE GROUND, SLABS
NOT EXPOSED TO EARTH OR WEATHER
1 1/2"#5 BARS OR SMALLER
2"#6 THROUGH #18 BARS
EXPOSED TO EARTH OR WEATHER
EXPOSED TO EARTH
3"CAST AGAINST AND PERMANENTLY
MINIMUM COVERDESCRIPTION
9. REINFORCING STEEL SHALL RECEIVE CONCRETE COVER AS FOLLOWS:
THEM.THEM. CLIP ANGLES SHALL BE FURNISHED BY THE CONTRACTOR REQUIRING
THEM AND INSTALLED BY THE CONTRACTOR CASTING THE CONCRETE AROUND
CONCRETE INSERTS SHALL BE FURNISHED BY THE CONTRACTOR REQUIRING
OR CONCRETE INSERTS FOR FASTENING AND SECURING OTHER COMPONENTS.
8. WHERE SHOWN ON THE DRAWINGS, PROVIDE WELD PLATES, WELDMENTS,
REINFORCING.
THE FOOTINGS WITH SAME SIZE AND QUANTITY DOWEL AS THE VERTICAL
AND PIERS, OR VERTICAL REINFORCING IN WALLS, SHALL BE DOWELED INTO
4, UNLESS OTHERWISE NOTED. ALL VERTICAL REINFORCING STEEL IN COLUMNS
7. PROVIDE FOUNDATION DOWELS AS SHOWN. MINIMUM SIZE DOWELS TO BE #
CORNER BARS, UNLESS NOTED OTHERWISE.
WALL, BEAM OR FOOTING. PROVIDE MINIMUM OF 40 BAR DIAMETER LAP FOR ALL
6. PROVIDE CORNER BARS OF SAME BAR DIAMETER AS SPECIFIED FOR THE
ON DRAWINGS (CLASS B SPLICE).
DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER, UNLESS NOTE OTHERWISE
5. LAP ALL REINFORCING SPLICES IN CONCRETE A MINIMUM OF 48 BAR
ACCORDANCE WITH THE LATEST ACI MANUALS.
4. ALL REINFORCING STEEL BARS TO BE DETAILED AND PLACED IN
LAPS SHALL BE ONE SPACE PLUS 2".
PLACING DETAILS OF ACI STANDARDS AND THE SPECIFICATIONS. MINIMUM
FROM OIL, SCALE AND RUST. PLACE WWF IN ACCORDANCE WITH THE TYPICAL
3. WELDED WIRE FABRIC TO CONFORM TO ASTM A185 AND SHALL BE FREE
EXCEPT WHERE NOTED OTHERWISE. REINFORCING SHALL NOT BE WELDED.
2. ALL REINFORCING STEEL TO BE ASTM A615, GRADE 60 (#4 AND LARGER),
STRAIGHTEDGE AND THE FLOOR SHALL NOT EXCEED 1/4".
SLAB CONCRETE PLACEMENT. THE GAP AT ANY POINT BETWEEN THE
ALLOWING IT TO REST UPON TWO HIGH SPOTS WITHIN 28 DAYS AFTER
(UNLEVELED) 10 FT. STRAIGHTEDGE ANYWHERE ON THE SLAB AND
FLOOR FINISH TOLERANCES AS MEASURED BY PLACING A FREESTANDING
ACI 117 ITEM 4.5.7
3/8" ENVELOPE EITHER SIDE OF THE THEORETICAL DESIGN SURFACE.
ELEVATIONS OF SLABS-ON-GRADE TOP OF SLAB ELEVATION SHALL BE WITHIN A
ACI 117 ITEM 4.3.1.1
EXCEPT AS MODIFIED BELOW:
1. ALL CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 301 AND ACI 117
CONCRETE AND REINFORCING PLACEMENT:
SLABS SHALL NOT EXCEED 3%.
INCLUDE AN AIR-ENTRAINING ADMIXTURE; THE MAXIMUM AIR CONTENT IN THESE
8. CONCRETE FOR TROWEL-FINISHED INTERIOR CONCRETE FLOORS SHALL NOT
ENGINEER'S WRITTEN PERMISSION FOR THEIR USE.
7. NO SALTS OF ANY KIND MAY BE USED IN CONCRETE BEFORE OBTAINING THE
PERMISSION OF THE ENGINEER IS GIVEN.
PLASTICIZERS AND SUPER-PLASTICIZERS MAY BE USED ONLY WHEN WRITTEN
6. WATER REDUCING AGENTS MAY BE USED IN THE CONCRETE MIX.
TO 5% TO 7%.
5. ALL CONCRETE EXPOSED TO WEATHER OR EARTH SHALL BE AIR ENTRAINED
THAN SPECIFIED.
TO RECEIVE SPECIAL CURING IF THE COMPRESSIVE STRENGTHS ARE LESS
SHALL DETERMINE IF THE CONCRETE IS ACCEPTABLE, OR TO BE REMOVED, OR
SPECIFICATIONS ARE MINIMUM COMPRESSIVE STRENGTHS. THE ENGINEER
4. THE CONCRETE STRENGTHS SHOWN IN THE SECTION ABOVE AND IN THE
BY THE GEOTECHNICAL ENGINEER OR GEOTECHNICAL REPORT.
3. CONCRETE SHALL UTILIZE TYPE I/II CEMENT UNLESS OTHERWISE DIRECTED
WITH THE APPROVAL OF THE ENGINEER.
CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY
AREAS IN THE CURING MEMBRANE SHALL BE RECOATED DAILY. CALCIUM
THE WATER HAS LEFT THE UNFINISHED CONCRETE. ALL SCUFFED OR BROKEN
SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS
STANDARD C309 TYPE 1 AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND
ABOVE. ALL SLABS SHALL BE CURED USING CURING COMPOUND MEETING ASTM
REPRESENTATIVE AND THE CONTRACTOR OF ANY NONCOMPLIANCE WITH THE
SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE OWNER'S
LONGER DELAY THAN STATED ABOVE, THE CONCRETE SHALL BE DISCARDED. IT
NOT EXCEED ONE AND ONE HALF (1-1/2) HOURS. IF FOR ANY REASON THERE IS A
MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL
CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM THE TIME THE
TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED WHEN
ALL THE REQUIREMENTS OF ASTM STANDARD C94 FOR MEASURING, MIXING,
NUMBER OR OTHER POSITIVE IDENTIFICATION. CONCRETE SHALL COMPLY WITH
TESTS FOR REVIEW PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX
2. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB
MAT SLAB FOUNDATIONS5,000 psi NWC -
INTERIOR SLABS-ON-GRADE3,000 psi NWC -
SPREAD FOOTINGS AND ASSOCIATED PIERS3,000 psi NWC -
WORKABLE MIX:
ACHIEVE A STRENGTH AT 28 DAYS AS LISTED BELOW WITH A PLASTIC AND
1. SHALL BE MIX DESIGNED BY A RECOGNIZED TESTING LABORATORY TO
CONCRETE MIX DESIGN:
ENGINEER.
THOSE LOCATED ON THESE DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE
NO PENETRATIONS SHALL BE MADE IN ANY STRUCTURAL MEMBERS OTHER THAN
PENETRATIONS:
THE ADDITIONAL CYLINDER(S) MAY BE DISCARDED.
DIRECTION OF THE ENGINEER, IF REQUIRED. IF 28 DAY STRENGTH IS ACHIEVED,
PROVIDE ONE ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER THE
2 AT 28 DAYS
1 AT 7 DAYS
AGE AS FOLLOWS:
THEREOF), PLACED PER DAY. REQUIRED CYLINDER(S) QUANTITIES AND TEST
CONDUCTED FOR EACH CLASS, FOR EVERY 50 CUBIC YARDS (OR FRACTION
CYLINDRICAL CONCRETE SPECIMENS." A SEPARATE TEST SHALL BE
B) ASTM C39 - "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF
CONCRETE."
A) ASTM C143 - "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT
CONCRETE:
LABORATORY SHALL PERFORM THE FOLLOWING TESTS ON CAST-IN-PLACE
1. CONCRETE TESTING SHALL BE PAID FOR BY THE OWNER. TESTING
CONCRETE TESTING:
WELDED WIRE MESHWWM
WELDED WIRE FABRICWWF
VERIFY IN FIELDVIF
VERTICALVERT
UNLESS NOTED OTHERWISEUNO
TYPICALTYP
TIE JOISTTJ
THICKNESSTHK
TOP OF xxT.O.xx
TOP OF WALLTOW
TOP OF STEELTOS
TOP OF CONCRETETOC
TOP AND BOTTOMT&B
TOP CHORD EXTENSIONTCX
SYMMETRICALSYM
SHORT WAYSW
STEELSTL
STANDARDSTD
SQUARESQ
SPECIFICATIONSPEC
SPECIAL JOISTSP
SLAB ON GRADESOG
SLABSL
SIMILARSIM
SHEETSHT
SECTIONSECT
SELF DRILLING SCREWSDS
SCHEDULESCHD
SLIP CRITICALSC
REVISIONREV
REQUIREDREQD
REINFORCEMENTREINF
REFERENCEREF
RADIUSR
PRESSURE TREATEDPT
PARRALEL STRAND LUMBERPSL
POUNDS PER SQUARE INCHPSI
POUNDS PER SQUARE FOOTPSF
POUNDS PER LINEAR FOOTPLF
PLATEPL
PRE-ENGINEEREDP/E
PRECASTPC
POWDER ACTUATED FASTENERPAF
OPENINGOPNG
OPPOSITE HANDOH
OUTSIDE FACEOF
ON CENTEROC
NORMAL WEIGHT CONCRETENWC
NOT TO SCALENTS
NOMINALNOM
NUMBERNo / #
METALMTL
MASONRY PILASTERMP
MISCELLANEOUSMISC
MINIMUMMIN
MIDDLEMID
MANUFACTURERMFR
MECHANICALMECH
MOMENT CONNECTIONMC
MAXIMUMMAX
MASONRYMAS
LIGHT WEIGHT CONCRETELWC
LONG WAYLW
LAMINATED VENEER LUMBERLVL
LAMINATED STRAND LUMBERLSL
LOCATIONSLOC
LOWLO
LONG LEG VERTICALLLV
LONG LEG HORIZONTALLLH
POUNDSLBS
KIPS PER LINEAR FOOTKLF
KIPS PER SQUARE INCHKSI
KNEE BRACEKB
KIPS = 1000 LBSK
JOINTJT
INTERIORINT
INSIDE FACEIF
HOLLOW STRUCTURAL SECTIONHSS
HIGH STRENGTH EPOXYHSE
HORIZONTALHORZ
HIGHHI
GRADE BEAMGB
GALVANIZEDGALV
GAUGEGA
FIELD VERIFYFV
FOOTINGFTG
FOOTING STEPFS
FACE OF WALLFOW
FACE OF MASONRYFOM
FOUNDATIONFND
FLOOR DRAINFD
FLOORFLR
FINISHFIN
EXTERIOREXT
EXPANSIONEXP
EXISTINGEXIST
EACH WAYEW
EQUIPMENTEQUIP
EQUALEQ
EDGE OF STEELEOS
EDGE OF DECKEOD
ENGINEERENGR
EMBEDDED / EMBEDMENTEMBED
ELEVATIONEL, ELEV
EXPANSION JOINTEJ
EACH FACEEF
EACHEA
DOWELDWL
DRAWINGSDWGS
DOWNDN
DECKDK
DIMENSIONDIM
DIAGONALDIAG
DIAMETERDIA
DETAILDET,DTL
DEGREEDEG
DOUBLEDBL
DEFORMED BAR ANCHORDBA
NAIL PENNY WEIGHTd
COMPLETE PENETRATIONCP
CONTINUOUSCONT
CONSTRUCTIONCONST
CONCRETECONC
COLUMNCOL
CONCRETE MASONRY UNITCMU
CLEARCLR
CONTROL JOINTCJ
CENTERLINECL
CANTILEVERCANT
BEARINGBRG
BEAMBM
BUILDINGBLDG
BOTTOM OF STEELBOS
BOTTOM OF xxB.O.xx
BOTTOMBOT
BELOW FINISHED FLOORBFF
BOTTOM CHORD EXTENSIONBCX
ARCHITECTARCH
ALTERNATEALT
ABOVE FINISHED FLOORAFF
ADJACENTADJ
ANCHOR BOLTSAB
DEFINITIONABBREV.
STRUCTURAL ABBREVIATIONS:
FLANGE WIDTH
MINIMUM METAL THICKNESS (mils)
TYPE OF MEMBER
DEPTH OF MEMBER
INDUSTRY-STANDARD NOMENCLATURE
600 S 162 - 43
6. LIGHT GAGE STRUCTURAL STEEL FRAMING AS SHOWN ON THESE PLANS
CONFORMS TO THE INDUSTRY-STANDARD NOMENCLATURE. EXPLANATION OF
THIS NOMENCLATURE IS SHOWN BELOW FOR REFERENCE:
LOCATED.
PROFESSIONAL ENGINEER, REGISTERED IN THE STATE WHERE THE PROJECT IS
CONCEPT ONLY. FINAL DESIGN AND DETAILING SHALL BE DONE BY A QUALIFIED
9. ALL COLD-FORMED FRAMING SHOWN ON THE STRUCTURAL DRAWINGS IS MINIMUM
PREPARATION.
REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED, RESPONSIBLE FOR THEIR
CALCULATIONS SIGNED AND SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER,
C. STRUCTURAL DESIGN CALCULATIONS: COMPLETE STRUCTURAL DESIGN
WHERE THE PROJECT IS LOCATED.
AND SEALED BY A QUALIFIED PROFESSIONAL ENGINEER, REGISTERED IN THE STATE
ADJOINING WORK. SHOP DRAWINGS MUST BE PREPARED UNDER THE SUPERVISION OF
BRIDGING, SPLICES, ACCESSORIES, CONNECTION DETAILS, AND ATTACHMENT TO
CHANNELS, OPENING FRAMING, SUPPLEMENTAL FRAMING, STRAPPING, BRACING,
ANCHORAGE DETAILS, INCLUDING MECHANICAL FASTENERS. SHOW REINFORCING
TYPES OF COLD-FORMED METAL FRAMING; FABRICATION; AND FASTENING AND
B. SHOP DRAWINGS: SHOW LAYOUT, SPACINGS, SIZES, THICKNESSES, AND
PRODUCT AND ACCESSORY INDICATED.
A. PRODUCT DATA: FOR EACH TYPE OF COLD-FORMED METAL FRAMING
8. SUBMITTALS:
STRUCTURAL MEMBERS”
“NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
7. DESIGN ALL MEMBERS ACCORDING TO AMERICAN IRON & STEEL INSTITUTE (AISI)
LOAD DEFLECTION OF PRIMARY BUILDING STRUCTURE OF 3/4" UPWARD OR DOWNWARD
OPENINGS, TO ALLOW FOR CONSTRUCTION TOLERANCES, AND TO ACCOMMODATE LIVE
6. DESIGN NON-LOAD BEARING FRAMING SYSTEM TO MAINTAIN CLEARANCES AT
COATING CONFORMING TO ASTM A525, CLASS G60.
5. COLD-FORMED STEEL SHALL SATISFY ASTM A653 WITH HOT DIPPED GALVANIZED
MEMBERS.
4. ASSUME NON-STRUCTURAL SHEATHING PROVIDES NO LATERAL BRACING TO FRAMING
1/360 BACKING OTHER MATERIALS
1/600 BACKING BRICK VENEEREXTERIOR WALL FRAMING:
1/360 (HORIZONTAL LOAD OF 5 psf.)INTERIOR WALL FRAMING:
OF THE WALL:
WITHOUT HORIZONTAL DEFLECTIONS GREATER THAN THE FOLLOWING FOR THE HEIGHT
3. DEFLECTION LIMITS: DESIGN FRAMING SYSTEMS TO WITHSTAND DESIGN LOADS
WIND, & SEISMIC DESIGN LOADS LISTED ON THE STRUCTURAL DRAWINGS.
2. COLD-FORMED METAL FRAMING SHALL BE CAPABLE OF WITHSTANDING DEAD, LIVE,
BEARING WALLS, FLOOR JOIST FRAMING, ROOF TRUSS AND RAFTER FRAMING.
THE FOLLOWING: EXTERIOR AND INTERIOR LOAD-BEARING WALL, EXTERIOR NON-LOAD
1. ENGINEER, FABRICATE AND INSTALL COLD-FORMED STRUCTURAL STEEL FRAMING FO
COLD FORMED LIGHT GAGE STRUCTURAL STEEL:
SPECIAL INSPECTION AND TESTING:
1. SPECIAL INSPECTION AND MINIMUM TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH 2012 NCSBC, TABLES 1704.3 (STEEL), 1704.4 (CONCRETE), AND
1704.5.1 (MASONRY).
2. INSPECTION & TESTING SHALL BE PROVIDED BY AN INDEPENDENT TESTING
AGENCY HIRED AT THE OWNER'S EXPENSE. AGENCY INSPECTION PERSONEL SHALL
MEET THE INSPECTOR QUALIFICATIONS FOR EACH MATERIAL ITEM AS INDICATED IN
THE SPECIFICATIONS. ALL RE-TESTING DUE TO FAILURE OF ORIGINAL TEST SHALL
BE PAID FOR BY THE GENERAL CONTRACTOR.
3. ANY MATERIAL OR PLACEMENT DEVIATIONS FROM MINIMUMS SHOWN ON THE
DRAWINGS OR IN SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE
ENGINEER.
ENGINEERED REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED.
DRAWINGS SHALL BEAR THE SIGNATURE AND SEAL OF A PROFESSIONAL
AS WELL AS ALL PERMANENT BRACING REQUIRED FOR TRUSS DESIGN. SHOP
DRAWING SHALL BE INCLUDED, IDENTIFYING ALL TRUSS SYSTEM COMPONENTS,
SUPPLIED AS PART OF THE ENGINEERED TRUSS SYSTEM. AN ERECTION
OTHER CONNECTIONS AND ATTACHMENTS BETWEEN TRUSSES OR COMPONENTS
TYPES UTILIZED WITHIN TRUSSES, AS WELL AS CONNECTORS UTILIZED IN ALL
FABRICATION. SHOP DRAWINGS SHALL SHOW AND SPECIFY ALL CONNECTOR
5. SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO
GALVANIZED COATING CONFORMING TO ASTM A525 (CLASS G-60).
OTHER) STEEL SECTIONS, COMPLYING WITH ASTM C995, WITH HOT DIPPED
4. TRUSS MEMBERS SHALL BE MANUFACTURER'S STANDARD C-SHAPED (OR
DEFLECTION OF L/360 LIVE LOAD AND L/240 TOTAL LOAD.
3. METAL ROOF TRUSSES SHALL BE DESIGNED FOR A MAXIMUM VERTICAL
BOTTOM CHORD.
RESISTING DEAD LOAD EQUAL TO 9 PSF ON THE TOP CHORD AND 0 PSF ON THE
2. WIND LOAD: WHEN CALCULATING NET UPLIFT REACTIONS, USE MAXIMUM
LIVE LOAD = 0 psf
DEAD LOAD = 5 psfBOTTOM CHORD:B)
WIND LOAD = SEE DESIGN LOADS
SNOW LOAD = 11 psf
LIVE LOAD = 20 psf
DEAD LOAD = 15 psfTOP CHORD:A)
FOLLOWS:
THE TRUSSES AND UNIFORM LOADS AS INDICATED ON THIS SHEET AND AS
DESIGNED AND DETAILED BY THE MANUFACTURER TO SUSTAIN SELF WEIGHT OF
1. PRE-ENGINEERED LIGHT GAGE METAL ROOF TRUSS SYSTEMS SHALL BE
PRE-ENGINEERED LIGHT GAGE METAL ROOF TRUSSES:
STRUCTURAL STEEL:
1. STEEL SHALL CONFORM TO ASTM A992 (Fy=50 ksi) FOR ALL W-SHAPES, AND
ASTM A36 (Fy=36 ksi) FOR ALL OTHER MISCELLANEOUS SHAPES AND PLATES.
STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B (Fy=46 ksi).
STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B, TYPE "E" OR "S"
(Fy=42 ksi).
2. STEEL SHALL CONFORM TO THE LATEST EDITION OF "SPECIFICATION FOR
THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR
BUILDINGS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC (AISC).
3. ALL STRUCTURAL STEEL EXPOSED TO EXTERIOR SHALL BE HOT-DIPPED
GALVANIZED.
4. ALL SHOP CONNECTIONS TO BE WELDED (UTLIZING E70XX ELECTRODES) AND
FIELD CONNECTIONS TO BE BOLTED, UNLESS OTHERWISE NOTED. STEEL TO
RECEIVE ONE SHOP COAT AND ONE FIELD TOUCH UP COAT OF APPROVED
PAINT, EXCEPT WHERE GALVANIZED IS INDICATED ON THE DRAWINGS.
5. WELDS FOR ALL EXPOSED STRUCTURAL STEEL SHALL BE GROUND SMOOTH
UNLESS NOTED OTHERWISE.
6. ALL BOLTED CONNECTIONS SHALL CONSIST OF 3/4" DIAMETER (MIN.) ASTM
A325 HIGH STRENGTH BOLTS, UNLESS NOTED OTHERWISE. BEAM
CONNECTIONS SHALL BE DESIGNED BY THE FABRICATOR TO SUPPORT AN END
REACTION OF Wc/2L KIPS IN ACCORDANCE WITH PART 2 - "BEAM AND GIRDER
DESIGN" OF THE MANUAL OF STEEL CONSTRUCTION (9th EDITION), BUT
CONNECTIONS SHALL NOT HAVE LESS THAN 2 ROWS OF BOLTS. SEE ALSO
DOUBLE ANGLE AND SHEAR TAB CONNECTION SCHEDULE(S) WHERE
APPLICABLE.
7. CONTRACTOR TO FURNISH AND INSTALL 500 lbs. OF ADDITIONAL
MISCELANEOUS STEEL TO BE USED AT ENGINEER'S DISCRETION.
SHEAR STUD CONNECTORS:
1. SHEAR STUD CONNECTORS SHALL BE FABRICATED AND INSTALLED IN
ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING CODE", SECTION 7 -
STUD WELDING. STUDS SHALL BE TYPE "B", HEADED STUDS, HAVING A MINIMUM
TENSILE STRENGTH OF 60,000 psi, AND SHALL BE OF LENGTH AND DIAMETER
SHOWN ON THE DRAWINGS.
COMPOSITE STEEL FORM DECK:
1. COMPOSITE FORM DECK SHALL BE THE SIZE INDICATED ON STRUCTURAL
DRAWINGS, GAGE G60 CORRUGATED STEEL COMPOSITE DECK AND SHALL
CONFORM TO THE PROVISIONS OF THE STEEL DECK INSTITUTE (SDI)
SPECIFICATIONS FOR COMPOSITE STEEL DECK.
STEEL ROOF DECK:
1. STEEL ROOF DECK SHALL BE THE SIZE INDICATED ON STRUCTURAL
DRAWINGS, PAINTED WIDE RIBBED STEEL ROOF DECK AND SHALL CONFORM TO
THE PROVISIONS OF THE STEEL DECK INSTITUTE (SDI) SPECIFICATIONS FOR
STEEL ROOF DECK.
2. STEEL ROOF DECKS ARE DESIGNED AS HORIZONTAL DIAPHRAGMS AND
SHALL BE ATTACHED TO SUPPORTS IN SDI PATTERNS AS INDICATED ON THE
DRAWINGS.
MASONRY PRISM TESTING:
1. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL CONSTRUCT THREE (3)
TEST PRISMS FOR TESTING. THEY SHALL BE CONSTRUCTED OF TWO (2) 8"x8"x16"
PRISMS FOR TESTING, ONE (1) ON TOP OF THE OTHER, JOINED WITH TYPE "S"
MORTAR, AND FILLED WITH 3,000 psi CONCRETE GROUT. PRISMS SHALL BE CURED
FOR 28 DAYS. NO REINFORCING SHALL BE USED IN THE CONSTRUCTION OF THE
PRISMS.
2. PRISMS SHALL BE MADE OF THE SAME MATERIALS, UNDER THE SAME CONDITIONS,
AND INSOFAR AS POSSIBLE, WITH THE SAME BONDING ARRANGEMENTS AS FOR THE
STRUCTURE. THE MOISTURE CONTENT OF THE UNITS AT THE TIME OF LAYING,
CONSISTENCY OF MORTAR, AND WORKMANSHIP SHALL BE THE SAME AS WILL BE
USED IN THE STRUCTURE. THE VALUE OF f'm SHALL BE THE AVERAGE OF ALL
SPECIMENS TESTED BUT SHALL BE NOT MORE THAN 125 PERCENT OF THE MINIMUM
VALUE DETERMINED BY THE TEST, WHICHEVER IS LESS.
3. TESTING SHALL INCLUDE TESTS IN ADVANCE OF BEGINNING OPERATIONS AS
DESCRIBED ABOVE, AND AT LEAST ONE (1) FIELD TEST DURING CONSTRUCTION FOR
EACH 5,000 SQUARE FEET OF WALL, BUT NOT LESS THAN ONE (1) FIELD TEST
MINIMUM IF TOTAL SQUARE FEET OF WALL FOR ENTIRE PROJECT IS LESS THAN 5,000
SF. ONLY WALLS INDICATED ON STRUCTURAL PLANS NEED BE TESTED.
4. THE COMPRESSIVE STRENGTH, f'm, SHALL BE COMPUTED BY DIVIDING THE
ULTIMATE LOAD BY THE NET AREA OF THE MASONRY USED IN THE CONSTRUCTION
OF THE PRISMS.
5. TEST PRISMS SHALL BE STORED FOR SEVEN DAYS IN AIR, AT A TEMPERATURE OF
70 DEGREES, PLUS OR MINUS 5 DEGREES, IN A RELATIVE HUMIDITY EXCEEDING 90%,
AND THEN IN AIR AT A TEMPERATURE OF 70 DEGREES, PLUS OR MINUM 5 DEGREES,
UNTIL TESTED. THOSE CONSTRUCTED IN THE FIELD SHALL BE STORED
UNDISTURBED FOR FROM 48 TO 96 HOURS UNDER WET MATERIAL TO SIMULATE 90%
HUMIDITY, THEN TRANSPORTED TO LABORATORY FOR CONTINUED CURING AS
DESCRIBED ABOVE.
6. NOT LESS THAN THREE (3) PRISM SPECIMENS SHALL BE MADE FOR EACH FIELD
TEST TO CONFIRM THAT THE MATERIALS ARE AS ASSUMED IN THE DESIGN. THE
STANDARD AGE OF TEST SPECIMENS SHALL BE 28-DAYS, BUT 7-DAY TESTS MAY BE
USED, PROVIDED THE RELATION BETWEEN THE 7-DAY AND 28-DAY STRENGTHS OF
THE MASONRY IS ESTABLISHED BY ADEQUATE TEST DATA FOR THE MATERIALS
USED.
MASONRY MATERIALS:
1. MASONRY UNITS SHALL MEET ASTM C90 TYPE I, GRADE N, FOR HOLLOW LOAD
BEARING TYPE MASONRY WITH A UNIT STRENGTH OF 1,900 psi ON THE NET AREA (f'm
= 1,500 psi).
2. MORTAR SHALL BE TYPE "M" (BELOW GRADE) OR "S" (ABOVE GRADE) AND SHALL
MEET ASTM C270. GROUT SHALL BE 3,000 psi PEA-GRAVEL CONCRETE AND SHALL
MEET ASTM C476. MORTAR MIX DESIGN SHALL BE TESTED PRIOR TO
CONSTRUCTION USING MORTAR TEST CUBES, WITH 7-DAY STRENGTH OF
LABORATORY MIX EXCEEDING THE 28-DAY SPECIFIED DESIGN STRENGTH. GROUT
SHALL BE TESTED PRIOR TO CONSTRUCTED USING PRISMS AS DESCRIBED ABOVE.
MASONRY AND REINFORCED MASONRY PLACEMENT:
1. ALL MASONRY SHALL BE LAID IN RUNNING BOND UNLESS NOTED OTHERWISE.
MATERIALS TO BE LAID AND MATERIALS TO BE BUILT UPON SHALL BE FREE FROM
SNOW AND ICE.
2. PROVIDE HOOKED DOWELS INTO FOOTINGS FOR ALL VERTICAL REINFORCING
ABOVE AS SHOWN IN THE DRAWINGS. LAP SPLICES A MINIMUM OF 48 BAR
DIAMETERS. AT THE OPTION OF THE CONTRACTOR, DOWELS MAY BE DRILLED AND
EPOXIED INTO FOOTING IN LIEU OF HOOKS. EPOXY SHALL BE AS NOTED ON THIS
SHEET UNDER 'CHEMICAL ANCHORS,' 6" MIN. EMBEDMENT FOR #5 OR SMALLER
DOWELS, 8" MIN. EMBEDMENT FOR #6 DOWELS.
3. PROVIDE DUR-O-WALL (OR EQUAL PER SPECIFICATIONS) LADDER OR TRUSS
HORIZONTAL JOINT REINFORCEMENT AT EACH SECOND COURSE IN RUNNING BOND,
AND EACH COURSE IN STACKED BOND, UNLESS NOTED OTHERWISE. DISCONTINUE
HORIZONTAL JOINT REINFORCEMENT AT CONTROL JOINTS.
4. PROVIDE BOND BEAMS REINFORCED WITH (2) #5 BARS EVERY 6'-0" OF VERTICAL
WALL, AT TOPS OF ALL MASONRY WALLS, AND WHERE SHOWN ON DRAWINGS. AT
BOND BEAM CORNERS AND TEE JOINTS, PROVIDE BENT BARS TO MATCH QUANTITY
AND BAR SIZE IN THE BOND BEAM. LAPS IN BOND BEAMS SHALL BE 48 BAR
DIAMETERS OR A MINIMUM OF 2'-0", WHICHEVER IS GREATER.
5. WHERE SHOWN ON THE DRAWINGS, CORES IN CONCRETE BLOCK UNITS SHALL BE
FILLED WITH 3,000 psi CONCRETE GROUT FROM TOP OF FOOTING TO BOTTOM OF
BEARING, OR TO THE TOP OF WALL, DEPENDING ON THE CONDITION. INSPECTION OF
OPENING AT BOTTOM IS REQURIED.
6. WHERE REINFORCING STEEL IS CALLED FOR IN FILLED CORES, IT SHALL EXTEND
FROM TOP OF FOOTING TO BOTTOM OF BEARING, OR TOP OF WALL, DEPENDING ON
CONDITION.
7. WHERE REINFORCING STEEL IS INTERRUPTED BY AN OPENING IN THE WALL, THE
QUANTITY OF BARS INTERRUPTED ARE TO BE MOVED TO EACH SIDE OF THE
OPENING, HALF OF REINFORCING TO ONE SIDE AND REMAINING HALF TO THE OTHER
SIDE. REINFORCING SHALL BE FROM TOP OF FOOTING TO TOP OF WALL. PROVIDE
A MINIMUM OF (2) #5 VERTICAL REINFORCING BARS AT EACH JAMB. SEE PLAN NOTES
AND/OR DETAILS FOR VERTICAL REINFORCING SPACING.
8. WHERE VERTICAL REINFORCING STEEL IS SPLICED IN MASONRY, PROVIDE A
MINIMUM OF 48 BAR DIAMETERS, LAP SPLICE, UNLESS NOTED OTHERWISE.
9. THE MINIMUM DISTANCE BETWEEN PARALLEL BARS, EXCEPT IN COLUMNS, SHALL
BE NOT LESS THAN THE DIAMETER OF THE BAR EXCEPT THAT LAPPED SPLICES MAY
BE WIRED TOGETHER. THE CENTER TO CENTER SPACING OF BARS WITHIN A
COLUMN SHALL BE NOT LESS THAN 2 AND ONE-HALF TIMES THE BAR DIAMETER.
10. ALL BARS SHALL BE COMPLETELY EMBEDDED IN MORTAR OR CONCRETE.
REINFORCEMENT EMBEDDED IN HORIZONTAL MORTAR JOINTS SHALL HAVE NOT LESS
THAN 5/8" MORTAR COVERAGE FROM THE EXPOSED FACE. ALL OTHER
REINFORCING SHALL HAVE A MINIMUM COVERAGE OF ONE BAR DIAMETER OVER ALL
BARS, BUT NOT LESS THAN 3/4", EXCEPT WHERE EXPOSED TO WEATHER OR SOIL IN
WHICH CASE THE MINIMUM COVERAGE SHALL BE 2".
11. WHERE REINFORCING IS SHOWN TO BE LOCATED ALONG TWO FACES OF A
CONCRETE BLOCK WALL, THE CONTRACTOR SHALL BREAK OUT THE SHELL OF THE
LOWEST CONCRETE BLOCK TO GAIN ACCESS TO THE REINFORCING STEEL. THE
REINFORCED STEEL SHALL THEN BE WIRED INTO ITS CORRECT POSITION, AND THE
ACCESS HOLE COVERED. THE CONCRETE GROUT FILL SHALL BE PUDDLED OR
VIBRATED TO ASSURE COMPLETE FILLING OF THE CORE.
12. REINFORCED MASONRY PIERS AND COLUMNS SHALL HAVE THE REINFORCING
STEEL ACCURATELY LOCATED BY WIRING THE TOP AND BOTTOM OF ALL VERTICAL
STEEL INTO ITS CORRECT POSITION. PROVIDE AN ACCESS HOLE AT THE BOTTOM
OF ALL COLUMNS OR PIERS.
13. ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE
UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND
CROSS WEBS FORMING SUCH CELLS TO BE FILLED SHALL BE FULLBEDDED IN
MORTAR TO PREVENT LEAKAGE OF CONCRETE GROUT. ALL HEAD (OR END) JOINTS
SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM THE FACE OF
THE WALL OR UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE
SHELLS. BOND SHALL BE PROVIDED BY LAPPING UNITS IN SUCCESSIVE VERTICAL
COURSES OR BY EQUIVALENT MECHNICAL ANCHORAGE.
A) VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO
MAINTAIN A CLEAR, UNOBSTRUCTED CONTINUOUS VERTICAL CELL MEASURING NOT
LESS THAN 2"x3".
B) CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF ALL CELLS TO BE
FILLED AT EACH POUR OF CONCRETE WHERE SUCH CONCRETE POUR IS IN EXCESS
OF 6' IN HEIGHT. ANY OVERHANGING MORTAR, OTHER OBSTRUCTION OR DEBRIS
SHALL BE REMOVED AND/OR CLEANED AT TIME OF INSPECTION AND PRIOR TO CORE
FILLING. INSPECT AND SEAL ALL OPENINGS BEFORE CONCRETING.
C) VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM
AND AT INTERVALS NOT EXCEEDING 192 DIAMETERS OF THE REINFORCEMENT.
D) ALL CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLIDLY WITH
CONCRETE. CONCRETE SHALL BE POURED IN LIFTS OF 8' MAXIMUM HEIGHT. ALL
CONCRETE SHALL BE CONSOLIDATED AT THE TIME OF POURING BY PUDDLING FOR
LIFTS OF 4' OR LESS, OR BY VIBRATING FOR LIFTS GREATER THAN 4'. CONCRETE
SHOULD LATER BE CONSOLIDATED AGAIN BY PUDDLING, BEFORE PLASTICITY IS
LOST.
E) WHEN TOTAL CONCRETE POUR EXCEEDS 8' IN HEIGHT, THE CONCRETE SHALL BE
PLACED IN 4' MAXIMUM LIFTS. MINIMUM CELL DIMENSION SHALL BE 3".
F) WHEN CONCRETING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL
CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF CONCRETE 1
1/2" BELOW THE TOP OF THE UPPERMOST UNIT.
14. PROVIDE A MINIMUM OF 8" BEARING FOR ALL MASONRY LINTELS.
15. WHERE LINTEL BLOCKS ARE USED IN LIEU OF HOLLOW CONCRETE BLOCKS, THE
REINFORCING STEEL SHALL BE ANCHORED TO THE LOWER STEEL OR DOWELS AND
THE LINTEL BLOCKS LAID AROUND THE STEEL. THE CONCRETE FILL SHALL BE
INSTALLED IN LIFTS NOT TO EXCEED 2' IN HEIGHT. THE REINFORCING STEEL SHALL
BE MAINTAINED IN THE SAME POSITION AS THE DOWELS. STOP THE POUR OF THE
CONCRETE 1 1/2" BELOW THE TOP OF THE UPPERMOST UNIT.
16. SPECIFICATION REQUIREMENTS FOR COLD WEATHER AND HOT WEATHER
MASONRY CONSTRUCTION SHALL BE MAINTAINED.
ACI 530-13 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES.
AISI S100-12 NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS
FACTOR AND EXPOSURE LISTED ABOVE.
THE NORTH CAROLINA STATE BUILDING CODE FOR THE BASIC DESIGN WIND VELOCITY, IMPORTANCE
ARE TO BE DESIGNED BY THE MANUFACTURER'S ENGINEER FOR WIND LOADS DETERMINED PER
ALL BUILDING COMPONENTS AND CLADDING ENGINEERED BY THE COMPONENT MANUFACTURER
COMPONENT & CLADDING:
155kVy =
142.5kVx = WIND BASE SHEARS,
IIIRISK CATEGORY
DEXPOSURE CATEGORY
145 mphBASIC WIND SPEED (3 SEC GUST)
WIND:
10 psfSUPERIMPOSED DEAD LOAD
FLOOR:
SNOW LOAD IMPORTANCE FACTOR
0.9Ce = SNOW EXPOSURE FACTOR
11 psfPf = DESIGN ROOF SNOW LOAD
Pg= GROUND SNOW LOAD
20 psfROOF LIVE LOAD
10 psfSUPERIMPOSED DEAD LOAD
ROOF:
SUPERIMPOSED LOADINGS:
THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED WITH THE FOLLOWING
DESIGN LOADS:
DSITE CLASSIFICATION
BDESIGN CATEGORY
E-L-FANALYSIS PROCEDURE USED:
3-1/4R = RESPONSE MODIFICATION FACTOR
.0581Cs = SEISMIC RESPONSE COEFFICIENT
54.7kVy =
54.7kVx = DESIGN BASE SHEARS
SEISMIC RESISTING SYSTEM:
0.096gSd1 =
0.126gSds = SPECTRAL RESPONSE COEFF.,
0.06gS1 =
0.91gSs = MAPPED SPECTRAL RESPONSE ACCELERATIONS,
RISK CATEGORY
1.25Ie =IMPORTANCE FACTOR,
SEISMIC:
1.0Ct = THERMAL FACTOR
1.10Is =
100 psfFLOOR LIVE LOAD (PUBLIC ROOMS & CORRIDORS)
100 psfSTAIRS
III
STEEL ORDINARY CONCENTRICALLY BRACED FRAMES
& INTERMEDIATE REINFORCED MASONRY SHEAR WALLS
10 psf
ROOF LIVE LOAD (PUBLIC) 100 psf
ELEVATED SLABS4,000 psi NWC -
FOUNDATION WALLS5,000 psi NWC -
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
GE
NE
RA
L
NO
TE
S
HMH
HMH
HMH
S0.1
Digitally signed by Heath M. HendrickDate: 2021.01.30 06:13:10 -05'00'
NOTES:
1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1
2. ELEVATIONS ON THE STRUCTURAL DRAWINGS REFER TO THE TOP OF CONCRETE REFERENCE
ELEVATION SET AT 0'-0"
3. FOR TYPICAL SLAB CONSTRUCTION DETAILS SEE SHEET S3.0.
4. FOR TYPICAL MASONRY WALL CONSTRUCTION DETAILS SEE SHEET S3.1.
5. VERIFY ALL DIMENSIONS & ELEVATIONS WITH ARCHITECTURAL DRAWINGS BEFORE CONSTRUCTION
COMMENCES
6. CENTERLINE OF FOOTING SHALL COINCIDE WITH THE FOUNDATION WALL AND COLUMN
CENTERLINE UNLESS NOTED OTHERWISE.
7. BACKFILL & COMPACT BOTH SIDES OF FOUNDATION WALL SIMULTANEOUSLY.
8. FOR SIZE AND LOCATION OF ROOF, FLOOR, AND WALL OPENINGS SEE MECHANICAL AND
ARCHITECURAL DRAWINGS.
9. MSW-X DENOTES MASONRY SHEARWALLS ABOVE. SEE SHEET S3.1 FOR REINFORCEMENT LAYOUTS.
W12x14F40
BP1-1'-4"
COLUMN SIZE
BASEPLATE MARK
FOOTING MARK
TOP OF FOOTING ELEV.
BELOW FINISHED FLOOR
SCALE: 1/8" = 1'-0"
FOUNDATION PLAN
1
1
3.6
5.5
4.6
2.6
1.8
21
'-6
"2
0'-0
"2
5'-0
"2
0'-0
"2
1'-6
"
1.5
2
3
4
5
6
10
'-4
"6
'-1
0 3
/4
"
4'-3
1
/4
"
8'-7
"
1'-1
1 3
/8
"
9'-3
"1
1'-1
1
/2
"8
'-1
0 1
/2
"1
1'-2
"1
0'-4
"
1
3.6
5.5
4.6
2.6
1.8
1.5
2
3
4
5
6
A.5A B E F
21'-6"
10'-4" 5'-11"
25'-0" 20'-0" 21'-6"
B.3 B.6
5'-10"
1'-4 1/2"
5'-3 1/2" 7'-6"
B.4
3.1
C.1C C.2 C.3
3"
1'-7"
2'-4 1/2"
18'-0 1/2"
11"
1'-7"
D.6 D.7D.5
7'-6"
2'-7"
1'-4 1/2"
5'-10"
E.2 E.5
4'-4 1/2"
6'-9 1/2" 10'-4"
A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8
C.9C.7 DC.8
3"
D.4
D.4
2'-8 1/2"
20'-0"
HSS8x8x3/8F-10.0
BP3-1'-0"
HSS8x8x3/8F-10.0
BP3-1'-0"
HSS8x8x3/8F-10.0
BP3-5'-0"
HSS8x8x3/8F-8.0
BP3-5'-0"
HSS8x8x3/8F-8.0
BP3-5'-0"
W8x31F-6.0
BP3-5'-0"
W8x31F-6.0
BP3-1'-4"
F-7.0
BP3-1'-4"
W8x48F-10.0
BP3-1'-4"
F-7.0
BP3-1'-4"
W8x31F-6.0
BP3-1'-4"
HSS6x6x1/4
BP2
F-7.0
BP3-5'-0"
F-9.0
BP3-5'-0"
F-4.0
BP2-1'-0"
W8x31F-7.0
BP3-1'-4"
W8x31F-8.0
BP3-1'-4"
BP1
W8x31F-7.0
BP3-1'-4"
F-4.0
BP2-1'-0"
W8x31F-8.0
BP3-1'-4"
F-9.0
BP3-1'-0"
F-8.0
BP3-1'-0"
F-4.0
BP2-1'-0"
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS6x6x1/4
HSS8x8x5/16HSS8x8x5/16
HSS6x6x1/4 HSS6x6x1/4
HSS8x8x5/16
HSS8x8x5/16
W8x31F-5.0
-5'-0" BP3
11
'-8
1
/2
"
3.2
2'-1
1
/8
"
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-5.0
BP3-3'-10"
F-5.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
HSS8x8x1/4
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
F-4.0
BP3-3'-10"
2.1 2.1
2'-6
"
A.8
A.8
5'-3"
HSS8x8x3/8F-9.0
BP3-1'-0"
W8x31F-6.0
-1'-4" BP3
2.8
5'-1
1
/2
"
3'-9
5
/8
"
2.8
3.1
3.2
HSS8x8x1/4
HSS8x8x1/4HSS8x8x1/4
HSS8x8x1/4HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4 HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
HSS8x8x1/4
SCHEDULE
MARK SIZE REINFORCING
F-5.0 5'-0"x5'-0"x18" (6)-#5 E.W. BOT & BOT
F-7.0 7'-0"x7'-0"x18" (12)-#5 E.W. BOT
SPREAD FOOTING
F-8.0 8'-0"x8'-0"x18" (13)-#5 E.W. BOT
F-9.0 9'-0"x9'-0"x24" (14)-#6 E.W. BOT
F-6.0 6'-0"x6'-0"x18" (10)-#5 E.W. BOT
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
F-10.0 10'-0"x10'-0"x24" (16)-#6 E.W. BOT
3'-8
"9
'-9
"
2'-9"
P-1
-1'-4"
P-1
-1'-4"
4'-0"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
P-1
-1'-4"
T.O. SLAB
-5'-0"
BP1
W8x40
6'-6" 6'-6"
5'-6
"
5'-6
"
MF-1
-3'-10"
P-1
-1'-4"
P-1
-1'-4"
F-4.0 HSS8x8x1/4
BP3-3'-10"
F-4.0 HSS8x8x1/4
6'-6" 6'-6"
6'-6
"
6'-6
"
BP1
HSS8x8x3/8
MF-1
-3'-10"
BP1
W8x40
P-1
-1'-4"
F-4.0 4'-0"x4'-0"x18" (5)-#5 E.W. TOP & BOT
W8x48F-10.0
BP3-1'-4"
W8x48F-10.0
BP3-1'-4"
W8x48F-10.0
BP3-1'-4"
P-1
-1'-4"
P-1
-1'-4"
SLAB-ON-GRADE/ AT GRADE
PATIO BEYOND. SEE
ARCHITECTURALS FOR
LAYOUT AND MATERIALS.
SCHEDULE
MARK WIDTH
REINFORCING
MF-2
MAT FOOTING
MF-1 SEE PLAN
SEE PLAN
DEPTH
36"
42"
LONGITUDINAL TRANSVERSE
#7 @ 10" TOP & BOT #7 @ 10" TOP & BOT
#7 @ 8" TOP & BOT #7 @ 8" TOP & BOT
MSW-1 12" CMU
MSW-1 12" CMU
MSW-2 8" CMU
2'-3" 11'-0 3/8" 8'-1 5/8"
4 5
/8
"
4'-8
"
9'-9"
7'-6
"
7'-6"
5'-9
"
7
S3.0
7
S3.0
SIM
6
S3.0
6
S3.0
5
S3.0
TYP. 4
S3.0
TYP.
4
S3.0
TYP.
4
S3.0
TYP.
4
S3.0
TYP.
4
S3.0
TYP.
NOTE:
3 BOLT ROWS TO BE
IN SAME DIRECTION
AS BRACE FRAME.
NOTE:
3 BOLT ROWS TO BE
IN SAME DIRECTION
AS BRACE FRAME.
6
S3.1
TYP.
6
S3.1
TYP.
6
S3.1
TYP.
6
S3.1
TYP.
8
S3.1
8
S3.1
8
S3.1
8
S3.1
5
S3.0
TYP.
SEE
ARCH
EXTENTS OF SLAB STEP.
SEE ARCH FOR STEP DIMENSION.
EXTENTS OF SLAB STEP.
SEE ARCH FOR STEP DIMENSION.
SEE
ARCH
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mo
n law
, statu
tory a
nd oth
er reserved
rights inclu
ding the
copyright the
reto.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
FO
UN
DA
TIO
N P
LA
N
HMH
HMH
HMH
S1.0
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN
1
1
3.6
5.5
4.6
2.6
1.8
21
'-6
"2
0'-0
"2
5'-0
"2
0'-0
"2
1'-6
"
1.5
2
3
4
5
6
10
'-4
"6
'-1
0 3
/4
"
4'-3
1
/4
"
8'-7
"
1'-1
1 3
/8
"
9'-3
"1
1'-1
1
/2
"8
'-1
0 1
/2
"1
1'-2
"1
0'-4
"
1
3.6
5.5
4.6
2.6
1.8
1.5
2
3
4
5
6
A.5A B E F
21'-6"
10'-4" 5'-11"
25'-0" 20'-0" 21'-6"
B.3 B.6
5'-10"
1'-4 1/2"
5'-3 1/2" 7'-6"
B.4
3.1
C.1C C.2 C.3
3"
1'-7"
2'-4 1/2"
18'-0 1/2"
11"
1'-7"
D.6 D.7D.5
7'-6"
2'-7"
1'-4 1/2"
5'-10"
E.2 E.5
4'-4 1/2"
6'-9 1/2" 10'-4"
A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8
C.9C.7 DC.8
3"
D.4
D.4
2'-8 1/2"
20'-0"
5'-0"
CANT.
W24x6235K 30K W27x8482K 80K
15K-FT.
9K
9K
W1
4x2
2 (8
)8
K8
K
W1
4x2
2 (8
)
8K
8K
W1
8x4
0 (8
)2
0K
26
KW
10
x1
2
1'-0
3
/4
"
W1
0x1
2 (8
)
W1
0x1
2 (8
)
W1
0x1
2 (8
)
W1
0x1
2 (8
)
W1
0x1
2
W18x40 (8)15K 13K
W18x3520K 22K 19K 20K W18x40 (8)20K 21K 21K 21K W16x31 (6)20K 17K
W24x68 (6)
39K 41K W18x35 18K 18K
W1
8x3
5W
10
x1
21
5K
21
K
W1
4x2
2 (8
)8
K8
K
W1
8x5
0
11
K
13
K
9K
9K
W1
6x2
6 (1
2)
12
K1
2K
W1
6x2
6 (1
2)
12
K1
2K
W1
8x3
5
17
K1
7K
W1
8x3
5
14
K1
7K
W21x50 (8)
4K
41K W16x26 (6)39K 35K W16x26 (6)19K 32K W16x31 (8)19K W21x44 (12) 31K 27K 34K W16x26
16K
W2
1x5
5 (1
6)
22
K
15
K
13
K1
3K
10
K1
0K
8K
8K
W1
6x2
6 (1
0)
HSS10x10x1/4 COL. ABOVE
W1
0x1
2
W10x12
HSS6x6x1/4 COL. ABOVE
W1
8x3
5 (8
)1
4K
14
K
11
K1
1K
19
K
W2
1x6
2
8K
16
K
8K
W1
6x2
6
W1
6x2
6
11
'-8
1
/2
"
3.2
2'-1
1
/8
"
VF
-2
KB KB KB KB KB KBKB KB KBKB
KBKB KB KB KBKB KB KB KB KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
W16x31 (6) W16x31 (6)
10K
W24x6232K 34K 29K 28K 32K 31K 26K 26K 34K 32KW24x62 W24x62 W24x62W24x62
W1
6x2
6 (1
2)
W1
6x2
6 (1
2)
W1
4x2
2 (8
)7
K7
K
7K
7K
W1
6x2
6 (1
2)
W1
6x3
1 (1
2)
W1
6x2
6 (8
)9
K9
K
W1
0x1
2 (8
)6
K6
K
W1
0x1
2 (8
)7
K7
K
W1
0x1
2 (8
)7
K7
K
W1
0x1
2 (8
)7
K7
K
W1
0x1
2 (8
)7
K7
K
W18x40
13K 15K
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2 (8
)W
10
x1
2
5K
5K
W1
4x2
2W
14
x2
2
KB
KB
W1
6x3
1W
16
x2
6 (6
)
18
K1
8K
18
K1
8K
18
K1
8K
W2
4x6
8 (1
4)
19
K1
9K
W2
4x7
6 (1
4)
21
K2
1K
W2
4x7
6 (1
4)
21
K2
1K
W2
4x7
6 (1
4)
22
K2
2K
W2
4x7
6 (1
4)
23
K
23
K
W2
4x7
6 (1
4)
23
K2
3K
W2
7x8
4 (1
4)
34
K3
4K
W2
4x6
8 (1
4)
20
K2
0K
W2
4x6
8 (1
4)
20
K2
0K
W2
4x6
8 (1
4)
19
K1
9K
W2
4x6
2 (1
4)
18
K1
8K
W2
4x6
2 (1
4)
18
K1
8K
W2
4x6
2 (1
4)
18
K1
8K
W1
6x3
1W
16
x2
6 (6
)
W1
0x1
2
2.1 2.1
2'-6
"
A.8
A.8
5'-3"
W1
W1
W1
W1
FIRST FLOOR LGS EXTERIOR WALL STUD SCHEDULE
MARK ZONE STUD
BOTTOM
TRACK
TOP TRACK
MAX.
HEIGHT
BRACING
W1
4
600S250-54 @ 16" O.C.
600T125-54 600T125-54 15'-4"
CRC w/ BC600 @ 5'-0" O.C. MAX.
5
600S250-54 @ 12" O.C.
600T125-54 600T125-54 15'-4"
CRC w/ BC600 @ 5'-0" O.C. MAX.
W2
4
800S250-54 @ 16" O.C.
800T125-54 800T125-54 15'-4"
CRC w/ BC800 @ 5'-0" O.C. MAX.
5
800S250-54 @ 12" O.C.
800T125-54 800T125-54 15'-4"
CRC w/ BC800 @ 5'-0" O.C. MAX.
2.8 2.8
5'-1
1
/2
"
3'-9
5
/8
"
HSS6x6x1/4 COL. ABOVE
HSS6x6x1/4 COL. ABOVE
44K
4K
HSS6x6x1/4 COL. ABOVE
HSS6x6x1/4 COL. ABOVE
HSS6x6x1/4 COL. ABOVE
3.1
3.2
3K
3K
3K
3K
W1
6x2
6
W16x26
W2
4x6
2 (1
4)
W2
4x6
2 (1
4)
W2
4x6
2 (1
4)
6K
MC
8K
MC
W1
6x3
16
K
MC
7K
MC
W1
6x3
18
K
MC
8K
MC
W1
6x3
19
K
MC
6K
MC
W1
6x3
16
K
MC
8K
MC
W1
6x3
1
6K
MC
8K
MC
W1
6x3
16
K
MC
7K
MC
W1
6x3
18
K
MC
8K
MC
W1
6x3
19
K
MC
6K
MC
W1
6x3
16
K
MC
8K
MC
W1
6x3
1
6K
MC
6K
MC
9K
MC
7K
MC
8K
MC
8K
MC
7K
MC
9K
MC
6K
MC
6K
MC
W16x31 W16x31 W16x31 W16x31 W16x31
6K
MC
6K
MC
9K
MC
7K
MC
8K
MC
8K
MC
7K
MC
9K
MC
6K
MC
6K
MC
W16x31 W16x31 W16x31 W16x31 W16x31
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W10x26 W10x26
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W10x26 W10x26
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K
4K 4
K
4K
4K
4K
4K
4K
5K 5K 5K5K
W10x12 5K5K
W10x12 4K4K
W10x12 4K4K
W10x124K
W10x12 4K4K
W10x12 4K4K
W10x12 4K4K
W10x12 3K3K
W10x12 3K3K
W10x12 3K3K
5K5K
W10x12 5K5K
W10x12 4K4K
W10x12 4K4K
W12x16 4K4K
W1
2x1
61
K1
K
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W10x12
W12x16
W1
2x1
6
5K5K
4K4K
4K4K
4K
4K
3K
4K 4K
4K
4K
4K 4K
4K
3K
3K3K
3K3K
1K
1K
4K4K
4K4K
4K4K
5K5K
5K5K
12
K1
2K
12
K1
2K
7K
6K
5K
6K
12
K1
5K
12
K1
2K
6K
3K
3K
4K
4K
4K
4K
4K
3K
6K
5K
5K
5K
5K
4K
5K
4K
5K
5K
5K
3K
6K
6K
6K
6K
6K
6K
6K
6K
3K
1
K
1
K
3K
3K
NOTES:
1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1
2. SEE ARCH FOR ALL DIMENSIONS NOT PROVIDED ON THIS SHEET.
3. TOP OF 2ND FLOOR STEEL, (T.O.S.) = +16'-8" UNLESS NOTED OTHERWISE, (U.N.O.)
4. ELEVATED SLAB TO BE 4" NW CONCRETE OVER 2VLI22 COMPOSITE DECK. SEE DETAIL
2/S4.0 FOR TYPICAL STUD PLACEMENT DETAILS.
5. MC DENOTES MOMENT CONNECTION - SEE DETAIL 6/S4.0.
6. TYPICAL COMPOSITE BEAM NOTATION:
VF
-1
ORNAMENTAL
STAIR BY
OTHERS.
SEE ARCH.
W18X46 (18)42K 42K
LEFT SHEAR
REACTION
BEAM SIZE # SHEAR STUDS
(UNIFORMLY SPACED)
RIGHT SHEAR
REACTION
*IF NO REACTIONS ARE PROVIDED, CONNECTIONS ARE TO BE
DESIGNED FOR MINIMUM SHEAR REACTION OF 4K
5K
5K
H2 H2 H2H2 H2
H1
AH
2
H2
H4
A
H2 H2 H2H2 H2
H1
AH
1A
H2
H2
NOTE:
ALL PORCH FRAMING T.O. STEEL ELEVATION TO BE -0'-1"
BELOW TYPICAL 2ND FLOOR TOP OF STEEL.
W2
W1
W1
W2
W1
NOTE:
HATCHED AREA INDICATED AREA OF MECHANICAL
MEZZANINE BELOW FRAMING. SEE MECHANICAL
MEZZANINE PLANS FOR FRAMING REQUIREMENTS AND
ELEVATION.
W1
0x1
2
5K
W1
0x1
2 (8
)
5K
W12x14 (8) 11K 9K
5
S4.0
10
S4.1
7
S4.0
TYP.
7
S4.0
TYP.
7
S4.0
TYP.
7
S4.0
TYP.
T.O.S. = +14'-11 7/8" T.O.S. = +14'-11 7/8" T.O.S. = +14'-11 7/8"T.O.S. = +14'-11 7/8"T.O.S. = +14'-11 7/8"
T.O. W16x26 = +14'-11 7/8" T.O. W16x26 = +14'-11 7/8"
17
S4.1
TYP.
W10x12
2K 2K
W10x12
2K 2K
W10x12
2K 2K
W10x12
2K 2K
W12x16 4K3KW12x16 3K4K
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
SE
CO
ND
F
LO
OR
FR
AM
IN
G P
LA
N
HMH
HMH
HMH
S1.1
HSS10X10X5/8
1
3.6
5.5
4.6
2.6
1.8
21
'-6
"2
0'-0
"2
5'-0
"2
0'-0
"2
1'-6
"
1.5
2
3
4
5
6
10
'-4
"6
'-1
0 3
/4
"
4'-3
1
/4
"
8'-7
"5
'-1
1
/2
"
1'-1
1 3
/8
"
11
'-8
1
/2
"9
'-3
"1
1'-1
1
/2
"8
'-1
0 1
/2
"1
1'-2
"1
0'-4
"
1
3.6
5.5
4.6
2.6
1.8
1.5
2
3
4
5
6
A.5A B E F
21'-6"
10'-4" 5'-11"
25'-0" 20'-0" 21'-6"
B.3 B.6
5'-10"
1'-4 1/2"
5'-3 1/2" 7'-6"
B.4
3.1
C.1C C.2 C.3
3"
1'-7"
2'-4 1/2"
18'-0 1/2"
11"
1'-7"
D.6 D.7D.5
7'-6"
2'-7"
1'-4 1/2"
5'-10"
E.2 E.5
4'-8 3/8"
6'-5 5/8" 10'-4"
A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8
C.9C.7 DC.8
3"
D.4
D.4
2'-8 1/2"
20'-0"
PRE-FABRICATED CFS ROOF TRUSSES
@ 24"oc (MAX.) (DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)
PRE-FABRICATED CFS ROOF TRUSSES @ 24"oc (MAX.)
(DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)
PR
E-F
AB
RIC
AT
ED
C
FS
R
OO
F T
RU
SS
ES
@
2
4"o
c (M
AX
.)
(D
ES
IG
N F
OR
N
ET
U
PL
IF
T P
RE
SS
UR
E =
2
8 P
SF
)
PR
E-F
AB
RIC
AT
ED
C
FS
R
OO
F T
RU
SS
ES
@
2
4"o
c (M
AX
.)
(D
ES
IG
N F
OR
N
ET
U
PL
IF
T P
RE
SS
UR
E =
2
8 P
SF
)
3.2
2'-1
1
/8
"
PRE-FABRICATED (SLOPED) CFS ROOF TRUSSES
@ 24"oc (MAX.) (DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)
SCALE: 1/8" = 1'-0"
ROOF FRAMING PLAN
1
VF
-2
KB KB KB KB KB KBKB KB KBKB
KBKB KB KB KBKB KB KB KB KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
KB
W16x26 (6)13K 18K 21K 19K W18x40 (8)23K 23K 17K 18K W16x26 (6)20K 16KW16x26 (6) W16x26 (6)
W24x6827K 36K W33x11854K 60K W12x14 W24x55 (12)29K 29K
W24x62
4K
39K W24x6218K 36K W24x6219K 32K W24x6218K W24x62 36K 27K 32K W24x62
14K 8K
W24x6231K 31K 26K 25K 29K 29K 23K 23K 30K 30KW24x62 W24x62 W24x62W24x62
W1
6x3
1
11
K1
1K
W1
8x4
01
1K
11
KW
14
x2
2 (6
)W
14
x2
2 (6
)
4K
W1
0x1
2 (8
)6
K
9K
W1
4x2
2 (8
)9
K
9K
W1
6x2
69
K
10
KW
16
x2
61
0K
W1
4x2
2 (8
)8
K8
K
W1
0x1
2 (8
)W
10
x1
2
W1
6x2
6 (1
2)
12
K1
2K
W1
6x2
6 (1
2)
12
K1
2K
W1
6x2
6 (1
2)
12
K1
2K
W1
0x1
2 (8
)W
10
x1
2
4K
4K
4K
4K
W1
4x2
2 (8
)
8K
8K
W1
0x1
2 (8
)W
10
x1
2
10
K
W1
6x2
6
10
K
W1
6x3
6 (1
0)
9K
9K
W1
6x2
6 (8
)1
0K
10
K
W1
6x2
6 (8
)1
0K
10
K
W1
6x2
6 (1
0)
11
K1
1K
W1
6x3
1 (1
2)
14
K1
3K
W1
6x3
1 (1
2)
14
K1
3K
W1
6x3
1 (1
2)
14
K1
3K
W1
6x3
1 (1
2)
14
K1
3K
W1
6x3
1 (8
)1
4K
12
K
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
W1
0x1
2
KB
KB
W1
4x2
2W
14
x2
2
W2
4x7
6
18
K1
8K
W2
4x6
2 (1
4)
19
K1
9K
W2
4x6
8
18
K1
8K
W2
4x6
8
18
K1
8K
W2
4x7
6 (1
4)
22
K2
2K
W2
4x7
6 (1
4)
22
K2
2K
W2
4x7
6 (1
4)
22
K2
2K
W2
4x7
6 (1
4)
23
K2
3K
W2
4x7
6 (1
4)
23
K2
3K
W2
4x6
8 (1
4)
21
K2
1K
W2
4x6
8 (1
4)
20
K2
0K
W2
4x6
8 (1
4)
20
K2
0K
W2
4x6
8 (1
4)
20
K2
0K
W2
4x6
2 (1
4)
20
K2
0K
W2
4x6
2 (1
4)
20
K2
0K
W2
4x6
2 (1
4)
20
K2
0K
W1
4x2
2 (6
)W
14
x2
2 (6
)
2.1 2.1
2'-6
"
A.8
A.8
5'-3"
W1
0x1
2
4K
6K
2.8
3'-9
5
/8
"
3.1
3.2
2.8
45K
15K
W1
6x3
1 (1
2)
14
K1
2K
W1
6x2
6
EXTENT OF ROOFTOP
BAR FLOOR AREA ABOVE
W24x62
2K
2K
W1
0x1
2
9K
9K
6K
6K
6K
6K
7K 6K
10
KW
16
x2
61
0K
10
KW
16
x2
61
0K
10
KW
16
x2
61
0K
10
KW
16
x2
61
0K
W12x222K
MC
4K
MC
4K
MC
3K
MC
W12x22 9K
MC
9K
MC
W16x36 3K
MC
4K
MC
W12x22 W12x224K
MC
2K
MC
W1
2x2
2
W1
2x2
2
W1
2x2
2
W1
2x2
2
W1
2x2
2
2K
2K
4K
4K
5K
5K
5K
5K
4K
4K
2K
2K
W1
2x2
22
K
MC
4K
MC
3K
MC
4K
MC
W1
2x2
24
K
MC
3K
MC
W1
2x2
63
K
MC
3K
MC
W1
2x2
63
K
MC
2K
MC
W1
2x2
6
W12x222K
MC
4K
MC
3K
MC
W12x22 3K
MC
4K
MC
4K
MC
W12x22 3K
MC
3K
MC
W12x22 4K
MC
2K
MC
W12x22
3K
MC
2K
MC
W1
2x2
63
K
MC
3K
MC
W1
2x2
64
K
MC
3K
MC
W1
2x2
63
K
MC
4K
MC
W1
2x2
2W
12
x2
22
K
MC
4K
MC
9K
9K
9K
9K
4K
4K
5K
4K
9K
9K
9K
9K
3K
3K
4K
3K
5K
4K
5K
5K
4K
4K
3K
3K
4K
3K
5K
5K
5K
5K
5K
5K
5K
5K
6K
6K
6K
4K
4K
NOTES:
1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1
2. SEE ARCH FOR ALL DIMENSIONS NOT PROVIDED ON THIS SHEETS.
3. TOP OF ROOF LEVEL STEEL (T.O.S.) = +33'-8" UNLESS NOTED OTHERWISE (U.N.O.)
4. ELEVATED SLAB TO BE 4" NW CONCRETE OVER 2VLI22 COMPOSITE DECK. SEE DETAIL
2/S4.0 FOR TYPICAL STUD PLACEMENT DETAILS.
5. MC DENOTES MOMENT CONNECTION - SEE DETAIL 6/S4.0.
6. TYPICAL COMPOSITE BEAM NOTATION:
(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")
(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
(T
.O
.S
. =
3
0'-3
")
VF
-1
W18X46 (18)42K 42K
LEFT SHEAR
REACTION
BEAM SIZE # SHEAR STUDS
(UNIFORMLY SPACED)
RIGHT SHEAR
REACTION
*IF NO REACTIONS ARE PROVIDED, CONNECTIONS ARE TO BE
DESIGNED FOR MINIMUM SHEAR REACTION OF 4K
H3 H3 H3 H3 H3
H3 H3 H3 H3 H3
H1
BH
3H
3
H1
BH
3H
3
W1
2x2
2
W12x22
(T.O.S. = 30'-3")
W1
W1
W1
W2
W1
W1
W2
W1
NOTE:
HATCHED AREA INDICATED AREA OF MECHANICAL
MEZZANINE BELOW FRAMING. SEE MECHANICAL
MEZZANINE PLANS FOR FRAMING REQUIREMENTS AND
ELEVATION.
SECOND FLOOR LGS EXTERIOR WALL STUD SCHEDULE
MARK ZONE STUD
BOTTOM
TRACK
TOP TRACK
MAX.
HEIGHT
BRACING
W1
4
600S250-54 @ 16" O.C.
600T125-54 600T125-54 15'-4"
CRC w/ BC600 @ 5'-0" O.C. MAX.
5
600S250-54 @ 12" O.C.
600T125-54 600T125-54 15'-4"
CRC w/ BC600 @ 5'-0" O.C. MAX.
W2
4
800S250-54 @ 16" O.C.
800T125-54 800T125-54 15'-4"
CRC w/ BC800 @ 5'-0" O.C. MAX.
5
800S250-54 @ 12" O.C.
800T125-54 800T125-54 15'-4"
CRC w/ BC800 @ 5'-0" O.C. MAX.
W1
0x1
2
W1
0x1
2
5K
4K
W1
0x1
24
K
W1
0x1
24
K
4K
4K
W12x14 (6)
14K 9K
HSS6x6x1/4 COL. ABOVE
15
S4.1
TYP.
15
S4.1
TYP.
15
S4.1
TYP.
15
S4.1
TYP.
15
S4.1
TYP.16
S4.1
16
S4.1
17
S4.2
17
S4.2
17
S4.2
SIM
17
S4.2
17
S4.2
SIM
EXTENT OF ROOFTOP
BAR FLOOR AREA ABOVE
HSS6x6x1/4 COL. ABOVE
HSS6x6x1/4 COL. ABOVE
HSS6x6x1/4
COL. ABOVE
HSS6x6x1/4
COL. ABOVE
HSS6x6x1/4
COL. ABOVE HSS6x6x1/4 COL. ABOVE
HSS6x6x1/4 COL. ABOVE
19
S4.2
TYP
GIRDER TRUSS
GIRDER TRUSS
GIRDER TRUSS
GIRDER TRUSS
GIRDER TRUSS
GIRDER
TRUSS
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
MA
IN
R
OO
F
FR
AM
IN
G P
LA
N
HMH
HMH
HMH
S1.2
HSS
12x6x1/4
SCALE: 1/8" = 1'-0"
HIGH ROOF FRAMING PLAN
1
1
3.6
5.5
4.6
2.6
1.8
21
'-6
"2
0'-0
"2
5'-0
"2
0'-0
"2
1'-6
"
1.5
2
3
4
5
6
10
'-4
"6
'-1
0 3
/4
"
4'-3
1
/4
"
8'-7
"
1'-1
1 3
/8
"
9'-3
"1
1'-1
1
/2
"8
'-1
0 1
/2
"1
1'-2
"1
0'-4
"
A.5A B E F
21'-6"
10'-4" 5'-11"
25'-0" 20'-0" 21'-6"
B.3 B.6
5'-10"
1'-4 1/2"
5'-3 1/2" 7'-6"
B.4
3.1
C.1C C.2 C.3
3"
1'-7"
2'-4 1/2"
18'-0 1/2"
11"
1'-7"
D.6 D.7D.5
7'-6"
2'-7"
1'-4 1/2"
5'-10"
E.2 E.5
4'-8 3/8"
6'-5 5/8" 10'-4"
A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8
C.9C.7 DC.8
3"
D.4
D.4
2'-8 1/2"
20'-0"
11
'-8
1
/2
"
3.2
2'-1
1
/8
"
1
3.6
5.5
4.6
2.6
1.8
1.5
2
3
4
5
6
MC MC MC MC MC MC
MC MC MC MC MC MC MC MC
MC
MC
MC
MC
MC
MC
1K
1K
2.1 2.1
2'-6
"
A.8
A.8
5'-3"
MCMC
2.8 2.8
5'-1
1
/2
"
3'-9
5
/8
"
3.1
3.2
6K 6K 4K 4K 6K 6K 3K 1K 2K 2K
1K1K
1K
1K
1K
1K
3K 1K10K 7K7K 10K
1K
1K
1K
1K
1K
1K
NOTES:
1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1
2. SEE ARCH FOR ALL DIMENSIONS NOT PROVIDED ON THIS SHEETS.
3. TOP OF HIGH ROOF STEEL (T.O.S.) = +45'- 1 1/8" UNLESS NOTED OTHERWISE (U.N.O.)
4. HIGH ROOF TO BE 1.5PLB22 OVER PREFABRICATED METAL ROOF TRUSSES.
5. MC DENOTES MOMENT CONNECTION - SEE DETAIL 6/S4.0.
6. TYPICAL COMPOSITE BEAM NOTATION:
W18X46 (18)42K 42K
LEFT SHEAR
REACTION
BEAM SIZE # SHEAR STUDS
(UNIFORMLY SPACED)
RIGHT SHEAR
REACTION
*IF NO REACTIONS ARE PROVIDED, CONNECTIONS ARE TO BE
DESIGNED FOR MINIMUM SHEAR REACTION OF 4K
PREFABRICATED ROOF TRUSSES BY OTHERS
(DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)
- SEE ARCH/MEP FOR ROOFTOP MECHANICAL
REQUIREMENTS AND PENETRATIONS, TYPICAL.
ORNAMENTAL
GAZEBO STRUCTURE BY
OTHERS - SEE ARCH FOR FINAL
LAYOUT AND MATERIALS.
1.5PLB22 ROOF DECK
OVER 10K1 BAR JOISTS @
24" O.C. OVER ELEVATOR
SHAFTS, TYP.
W1
2x1
4
W12x14
H6
H6H6
H6H5H6H7H6
H6
H6
ROOF LGS EXTERIOR WALL STUD SCHEDULE
MARK ZONE STUD
BOTTOM
TRACK
TOP TRACK
MAX.
HEIGHT
BRACING
W1
4
600S250-54 @ 16" O.C.
600T125-54 600T125-54 15'-4"
CRC w/ BC600 @ 5'-0" O.C. MAX.
5
600S250-54 @ 12" O.C.
600T125-54 600T125-54 15'-4"
CRC w/ BC600 @ 5'-0" O.C. MAX.
W2
4
800S250-54 @ 16" O.C.
800T125-54 800T125-54 15'-4"
CRC w/ BC800 @ 5'-0" O.C. MAX.
5
800S250-54 @ 12" O.C.
800T125-54 800T125-54 15'-4"
CRC w/ BC800 @ 5'-0" O.C. MAX.
KB
KB
KB
KB
W1
W1
W1
W1
W1
HSS
12x6x1/4
HSS
12x6x1/4
HSS
12x6x1/4
HSS
12x6x1/4
HSS
12x6x1/4
HS
S
12
x6
x1
/4
HSS
12x6x1/4
HSS
12x6x1/4
HSS
12x6x1/4
HS
S
12
x6
x1
/4
HS
S
12
x6
x1
/4
HS
S
12
x6
x1
/4
HS
S
12
x6
x1
/4
HS
S
12
x6
x1
/4
NOTE:
ALL ROOFTOP BAR LEVEL
COLUMNS TO BE HSS 6x6x1/4
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
HIG
H R
OO
F
FR
AM
IN
G P
LA
N
HMH
HMH
HMH
S1.3
A.5
1.5
1.8
2
2.1
2.6
3
3.1
3.2
A.8 B B.3 B.6 C C.1 C.2
1.5
1.8
2
2.1
2.6
3
3.1
3.2
A.5 A.8 B B.3
B.4
B.6 C C.1 C.2B.4
1000S162-54 @ 16" O.C.
1000S162-54 @ 16" O.C.
1000S162-54 @ 16" O.C.
10
00
S1
62
-5
4 @
1
6" O
.C
.
10
00
S1
62
-5
4 @
1
6" O
.C
.
10
00
S1
62
-5
4 @
1
6" O
.C
.
10
00
S1
62
-5
4 @
1
6" O
.C
.
SCALE: 1/4" = 1'-0"
FIRST FLOOR MECHANICAL MEZZANINE PLAN
1
W3
W2
W3
W3
W4
W3
W4
W3
W3
W4
W4
W3
H8 H8 H8
H1
0H
10
H11
NOTES:
1. T.O. LGS JOIST ELEVATION = +9'-4" UNLESS NOTED OTHERWISE (U.N.O.)
2. TYPICAL MEZZANINE FLOOR TO BE 0.6C26 METAL DECK w/ 1" TOPPING. (TOTAL THICKNESS = 1-5/8". SEE DETAIL 13/S4.1)
H1
1
1000S162-97 AT FLOOR
OPENING
HSS10X10X5/8
A.5
1.5
1.8
2
2.1
2.6
3
3.1
3.2
A.8 B B.3 B.6 C C.1 C.2
1.5
1.8
2
2.1
2.6
3
3.1
3.2
A.5 A.8 B B.3
B.4
B.6 C C.1 C.2B.4
10
00
S1
62
-5
4 @
1
6" O
.C
.
1000S162-54 @ 16" O.C.
1000S162-54 @ 16" O.C.
SCALE: 1/4" = 1'-0"
SECOND FLOOR MECHANICAL MEZZANINE PLAN
2
W4
W3
W3
W3
W1
W2
H8 H8
H8 H9
NOTES:
1. T.O. LGS JOIST ELEVATION = +26'-4" UNLESS NOTED OTHERWISE (U.N.O.)
2. TYPICAL MEZZANINE FLOOR TO BE 0.6C26 METAL DECK w/ 1" TOPPING. (TOTAL THICKNESS = 1-5/8". SEE DETAIL 13/S4.1)
1000S162-97 AT FLOOR
OPENING
MECHANICAL MEZZANINE WALL STUD SCHEDULE
MARK STUD
MAX.
HEIGHT
BOTTOM TRACK TOP TRACK BRACING
W3
362S200-43 @ 16" O.C.
16'-8" 362T125-43 362T125-43
CRC w/ BC1 @ 5'-0" O.C. MAX.
W4
600S162-43 @ 16" O.C.
16'-8" 600T125-43 600T125-43
CRC w/ BC1 @ 5'-0" O.C. MAX.
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
FR
AM
IN
G P
LA
NS
ME
CH
AN
IC
AL
PLA
TF
OR
M
HMH
HMH
HMH
S1.4
16'-8"
T.O. STEEL
1.5 2.6
33'-8"
T.O. STEEL
0'-0"
F.F.E.
SCALE: 1/2" = 1'-0"
VF-1 ELEVATION (VIEWED FROM EXTERIOR)
1
16'-8"
T.O. STEEL
1.52.6
33'-8"
T.O. STEEL
0'-0"
F.F.E.
SEE PLAN
T.O. SLAB
SCALE: 1/2" = 1'-0"
VF-2 ELEVATION (VIEWED FROM EXTERIOR)
2
WIDE FLANGE BEAM. SEE PLAN.
WIDE FLANGE BEAM. SEE PLAN.
H
S
S
8
x
8
x
1
/
4
M
A
X
T
/
C
=
7
7
K
(
1
.
0
W
)
WID
E F
LA
NG
E C
OL
UM
N. S
EE
P
LA
N.
HS
S C
OL
UM
N. S
EE
P
LA
N.
WIDE FLANGE BEAM. SEE PLAN.
WIDE FLANGE BEAM. SEE PLAN.
H
S
S
8
x
8
x
1
/
4
M
A
X
T
/
C
=
7
7
K
(
1
.
0
W
)
WID
E F
LA
NG
E C
OL
UM
N. S
EE
P
LA
N.
HS
S C
OL
UM
N. S
EE
P
LA
N.
H
S
S
8
x
8
x
1
/
4
M
A
X
T
/
C
=
1
3
0
K
(
1
.
0
W
)
SEE PLAN
T.O. SLAB
H
S
S
8
x
8
x
1
/
4
M
A
X
T
/
C
=
1
3
0
K
(
1
.
0
W
)
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
BR
AC
E F
RA
ME
ELE
VA
TIO
NS
HMH
HMH
HMH
S2.0
PREPARE SLAB SUBGRADE AS PER
THE GEOTECHNICAL ENGINEER'S
RECOMMENDATIONS
4" GRANULAR BASE, PER THE
GEOTECHNICAL ENGINEER'S
RECOMMENDATIONS
4" CONC SLAB
NOTES:
1. SEE ARCHITECTURAL DRAWINGS FOR SLOPES, DROPS,
AND DRAIN LOCATIONS IN FLOOR SLABS.
VAPOR BARRIER, SEE ARCH DWGS
6"x6" - W2.9xW2.9 WELDED WIRE
MESH. WELDED WIRE MESH MUST
BE PREFABRICATED SHEETS, NO
ROLLED MESH ALLOWED. PROVIDE
A MINIMUM OF ONE CHAIR PER 25
SQ. FT. OF MESH SUPPORTED
NOTES:
1. CONTRACTORS OPTION - USE REMOVABLE CONTROL JOINT MATERIAL SUCH AS
"ZIP STRIP", "STRESSLOCK", OR APPROVED EQUAL.
2. SLAB ON GRADE CONTROL JOINTS SHALL BE TOOLED OR SAWCUT. THE JOINT
PATTERN SHALL BE APPROXIMATELY SQUARE AND LIMITED TO AN AREA NOT TO
EXCEED 225 S.F. JOINTS SHALL BE CUT WITHIN 12 HOURS OF POURING SLAB. SEE
PLAN FOR PROPOSED JOINT LAYOUT. FINAL JOINT LAYOUT TO BE DETERMINED BY
THE GENERAL CONTRACTOR.
3/16" SAWCUT CONTROL JOINT. HAND CUT ENDS TO
3/4" MAX. FROM VERTICAL SURFACES. CLEAN JOINT
AND FILL w/ ELASTOMERIC JOINT SEALANT, CUT
JOINT TO A DEPTH OF 1/4 OF THE SLAB THICKNESS
SLAB REINFORCING, SEE TYP
SLAB ON GRADE DETAIL
CONSTRUCTION JOINT TO HAVE A TOOLED
1/8" MAX. EDGE RADIUS IN ALL AREAS
WHERE SLAB IS EXPOSED TO VIEW. CLEAN
JOINT AND FILL WITH ELASTOMERIC JOINT
SEALANT, UNLESS NOTED OTHERWISE.
SLAB REINFORCING, SEE
TYP SLAB ON GRADE DETAIL
1'-0" 8" 1'-0"
8"
2'-4"x2'-4" SUMP BASE
w/ (4) #4 HAIRPINS
EACH WAY
CONC. SLAB ON GRADE
SEE DTL.
PREPARE SUBGRADE PER
THE GEOTECHNICAL ENGINEER'S
RECOMMENDATIONS
12" CMU SHEARWALL (8" CMU SIM.)
SEE PLAN FOR REINF.
(-5'-0")
T.O.F.
(0'-0")
F.F.E.
NOTE:
CONFIRM REQUIRED PIT
DEPTH WITH ELEVATOR
MANUFACTURER
MAT FOUNDATION BELOW
ELEVATOR - SEE PLAN
FOR EXTENTS.
SE
E
SC
HE
DU
LE
#5 HORIZ. @ 12" O.C.
#6 VERT. @ 12" O.C. TYP.
#6 @ 8" O.C. TO MATCH QUANTITY OF CHORD
REINFORCEMENT OF SHEAR WALL CHORDS
ABOVE. SEE MASONRY WALL SCHEDULES
AND REINFORCEMENT DETAILS.
NOTE:
8" CIP STEM WALL REQUIRES
(1) ROW OF REINFORCEMENT
ONLY (CENTERED).
(1) #4 EDGE BAR,
TYP
#3 HOOKS @ 18"
O.C., TYP
#6 VERT. @ 12" O.C. TYP.
#6 @ 8" O.C. TO MATCH QUANTITY
OF CHORD REINFORCEMENT OF
SHEAR WALL CHORDS ABOVE. SEE
MASONRY WALL SCHEDULES AND
REINFORCEMENT DETAILS.
2'-4"x2'-4" SUMP BASE
w/ (4) #4 HAIRPINS
EACH WAY
16"dia ELEVATOR PIT SUMP w/
#5 x 5'-0"L ADDT'L. REINF. ALONGSIDE
OPENING T&B (TYP EACH WAY)
SEE PLAN
8"
TY
P
#5 HORZ REBAR @
12" O.C.
PREPARE SUBGRADE PER
THE GEOTECHNICAL ENGINEER'S
RECOMMENDATIONS
(-5'-0")
T.O.F.
NOTE:
CONFIRM REQUIRED PIT
DEPTH WITH ELEVATOR
MANUFACTURER
(1) #4 EDGE BAR,
TYP
#3 HOOKS @ 18"
O.C., TYP
MAT FOUNDATION BELOW
STAIR TOWERS - SEE
PLAN FOR EXTENTS.
SE
E
SC
HE
DU
LE
#5 HORIZ. @ 12" O.C.
#6 VERT. @ 12" O.C. TYP.
#6 @ 8" O.C. TO MATCH QUANTITY OF CHORD
REINFORCEMENT OF SHEAR WALL CHORDS
ABOVE. SEE MASONRY WALL SCHEDULES
AND REINFORCEMENT DETAILS.
MAT FOUNDATION BELOW
STAIR TOWERS - SEE
PLAN FOR EXTENTS.
VARIES
MATCH CMU WIDTH ABOVE.
SCALE: 3/4" = 1'-0"
CAST-IN-PLACE CONCRETE PEDESTIALS (P-1)
4
ELEVATION
HSS-COLUMN & WIDE FLANGE
COLUMN, SEE PLAN
C
L
COLUMN BASEPLATE ON 1 1/2" GROUT
BED. FASTEN TO FOOTING W/ (4) 3/4" Ø
SIMPSON PAB6 W/ LEVELING NUTS
SE
E
PL
AN
COLUMN FOOTING
SEE PLAN
2"
#4
T
IE
S @
1
2"o
.c.
(M
AX
)
2"
2"
(2)-LATERAL TIES AT TOP OF
PEDESTAL AS SHOWN (TYP.)
A
SEE PLAN
16"dia ELEVATOR PIT SUMP w/
#5 x 5'-0"L ADDT'L. REINF. ALONGSIDE
OPENING T&B (TYP EACH WAY)
#3 HOOKS @ 18"
O.C., TYP
8"
TY
P
#3 HOOKS @ 16"
O.C., TYP
(1) #4 EDGE BAR,
TYP
(1) #4 EDGE BAR,
TYP
3'-4
"
SEE PLAN
CONC. SLAB ON GRADE
SEE DTL.
#5 HORIZ. @ 12" O.C.
#6 VERT. @ 12" O.C. TYP.
#6 @ 8" O.C. TO MATCH QUANTITY OF CHORD
REINFORCEMENT OF SHEAR WALL CHORDS
ABOVE. SEE MASONRY SHEAR WALL
SCHEDULE AND REINFORCEMENT DETAILS.
#3 HOOKS @ 18"
O.C., TYP
8"
TY
P
#3 HOOKS @ 16"
O.C., TYP
(1) #4 EDGE BAR,
TYP
(1) #4 EDGE BAR,
TYP
3'-4
"
8" CMU WALL w/ #6 VERT @ 40" oc -
GROUT SOLID ALL CELLS (TYP.)
#6x72" DOWEL, ALIGN w/
CMU WALL VERT. REBAR
3'-4
"
(0'-0")
F.F.E.
(2) #6x72" DOWEL, ALIGN w/
CMU WALL VERT. REBAR. (1 #6x72"
DOWEL FOR 8" CMU)
3"
2"
3"
2"
8"
TYP
8"
TYP
(0'-0")
F.F.E.
SEE PLAN
T.O. PEDESTAL
SEE PLAN
T.O. FOOTING
SECTION A
2'-6
"
2'-6"
EXTENT OF COLUMN
BASEPLATE ABOVE
(HSS SIMILAR)
(8)-#6 VERT.
#4 TIES @ 12"o.c.
HSS COLUMN & WIDE FLANGE COLUMN, SEE PLAN
SLAB-ON-GRADE
(TYP.)
C
L
SE
E
PL
AN
3"
COLUMN BASEPLATE ON 1 1/2" GROUT
BED. FASTEN TO FOOTING W/ SPECIFIED
ANCHOR BOLTS W/ LEVELING NUT &
HEAVY HEX WASHER. SEE BASEPLATE
SCHEDULE FOR FASTENER SIZE, COUNT,
AND EMBEDMENT.
1 1
/2
"
COLUMN ISOLATION JOINT
POUR SOLID ONCE COLUMN
IS ERECTED AND PLUMB
COLUMN FOOTING/SLAB
SEE PLAN
COLUMN BASEPLATE
SCHEDULE
MARK B H
BP2 12"
THICKNESS
12" 3/4"
2"
BP3 14" 14" 3/4"
B
H
1 1
/2
"
1 1/2"
(4) 3/4" DIA. SIMPSON
PAB6 ANCHOR BOLTS
(TYP.) (8" EMBEDMENT)
COLUMN BASEPLATE
- SEE SCHEDULE
HSS-COLUMN &
W-COLUMN, SEE PLAN
SCALE: 3/4" = 1'-0"
SECTION - TYPICAL COLUMN & BASE PLATE
5
B
H
1 1
/2
"
1 1/2"
(4) 3/4" DIA. SIMPSON
PAB6 ANCHOR BOLTS
(TYP.) (8" EMBEDMENT)
COLUMN BASEPLATE
- SEE SCHEDULE
HSS-COLUMN &
W-COLUMN, SEE PLAN
BP1 16" 16" 1"
(0'-0")
F.F.E.
SEE PLAN
T.O. FOOTING/SLAB
B
H
2" 2"
2"
2"
BP1
(6) 1" DIA. SIMPSON
PAB8H ANCHOR BOLTS
(TYP.) (30" EMBEDMENT)
COLUMN BASEPLATE
- SEE SCHEDULE
HSS-COLUMN &
W-COLUMN, SEE PLAN
BP2 BP3
SCALE: 3/4" = 1'-0"
TYPICAL SLAB-ON-GRADE
1
SCALE: 3/4" = 1'-0"
TYPICAL CONTROL JOINT
2
SCALE: 3/4" = 1'-0"
TYPICAL CONSTRUCTION JOINT
3
SCALE: 3/4" = 1'-0"
SECTION - ELEVATOR PIT
6
SCALE: 3/4" = 1'-0"
SECTION - ELEVATOR PIT
7
NOTE: 3 BOLT ROWS TO
BE IN SAME DIRECTION
AS BRACE FRAME.
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mo
n law
, statu
tory a
nd oth
er reserved
rights inclu
ding the
copyright the
reto.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
FO
UN
DA
TIO
N
DE
TA
ILS
HMH
HMH
HMH
S3.0
6"
FTG.
1'-0
"
3'-0"
8" CMU
(3) #5 BARS LONGITUDINAL
TOP AND BOTTOM
4" SLAB-ON-GRADE
(TYP.)
TYPICAL SLAB-ON-GRADE
SEE DETAIL FOR REINF.
T.O.C.
F.F.E.
#5 NOSING BAR AT
EDGE (TYP.)
(2) #5 CONT. (TYP.)
1'-4
"
1'-0"
2 3
/4
"
CL
R.
OPTIONAL:
NOTCHED SLAB MAY BE PLACED IN
SEPARATE POURS AT CONTRACTOR'S
OPTION. IF CHOSEN, SCARIFY TOP OF
INITIAL FOOTING LUG, AND APPLY
BONDING AGENT TO EXPOSED FACE
PRIOR TO SLAB PLACEMENT.
EXTERIOR LIGHT-GUAGE STUD
FRAMING. FOR SHEATHING AND
VENEER INFO - SEE ARCH.
BRICK VENEER. SEE ARCH.
REINFORCING NOTES:
1. SEE GENERAL NOTES FOR ALL MATERIAL SPECIFICATIONS.
2. MASONRY SHALL BE LAID IN RUNNING BOND UNLESS NOTED OTHERWISE.
3. LAP SPLICES SHALL BE A MINIMUM OF 48 BAR DIAMETERS, U.N.O.
4. PROVIDE DUR-O-WALL (OR EQUAL) LADDER OR TRUSS TYPE HORIZONTAL
JOINT REINFORCEMENT AT EACH SECOND COURSE IN RUNNING BOND, AND
AT EACH COURSE IN STACKED BOND, UNLESS NOTED OTHERWISE.
DISCONTINUE HORIZONTAL JOINT REINFORCEMENT AT WALL CONTROL JOINTS.
5. MASONRY BOND BEAMS REINFORCED WITH (2)-#5 BARS ARE TO BE PROVIDED
EVERY 4-0" OF VERTICAL WALL, AT TOPS OF ALL MASONRY WALLS, AND WHERE
SHOWN ON DRAWINGS. FIRST BOND BEAM MAY BE PLACED AT TOP OF DOOR
OPENINGS, 8'-0" MAX. AT BOND BEAM CORNERS AND TEE JOINTS, PROVIDE BENT
BARS TO MATCH QUANTITY AND BAR SIZE IN THE BOND BEAM. REINFORCING LAP
SPLICES W/IN BOND BEAMS SHALL BE 48 BAR DIAMETERS OR A MINIMUM OF 2'-0",
WHICHEVER IS GREATER.
6. ALL MASONRY CELLS ARE TO BE GROUTED SOLID UNLESS NOTED OTHERWISE.
7. SEE PLANS AND DETAILS FOR ADDITIONAL REINFORCING REQUIREMENTS AT SUPPORTS,
TERMINATIONS, WALL INTERSECTIONS, AND MASONRY SHEAR WALL CHORDS.
CMU WALL REINFORCING SCHEDULE
APPLICATION / MARK BLOCK SIZE REINFORCING
TYP. SHAFT WALLS
TYP. SHAFT WALLS
8"
12"
#6 @ 40oc.
(2) #6 @ 40oc.
NOTES
-
-
TYPICAL
12" CMU
TYPICAL
8" CMU
GROUT SOLID AT ALL
REINFORCED CELLS
U.N.O. (TYP.)
SCALE: 3/4" = 1'-0"
TYPICAL MASONRY REINFORCING SCHEDULE
2
NOTES:
1. CMU LINTELS ARE PERMITTED ON AT EXTERIOR WALLS, AND TOP FLOOR
INTERIOR WALLS ONLY - ALL LOWER LOAD BEARING WALLS ARE TO USE
STEEL LINTELS AS DETAILED.
2. LINTEL DESIGN ASSUMES ARCHING ACTION OF BLOCK. NO WALL PENETRATIONS
ARE PERMITTED WITHIN SPAN/2 OR 24", (WHICH EVER IS GREATER), MEASURED
FROM TOP OF LINTEL. SHOULD PENETRATIONS BE REQUIRED WITHIN THIS AREA,
A STEEL LINTEL BEAM IS TO BE SUBSTITUTED PER THE PROVIDED DETAILS.
3. CMU LINTEL BEAMS ARE TO BEAR 8" (MIN.) ON EITHER SIDE OF OPENING.
HORIZONTAL REINFORCING IS TO BE CONTINUOUS OVER THE FULL SPAN + BEARING.
4. SEE DETAILS FOR TYPICAL JAMB REINFORCING.
5. REFER TO GENERAL REINGFORCING NOTES FOR ADDT'L. WALL CONSTRUCTION DETAILS.
CMU LINTEL SCHEDULE
MAX. OPENING BLOCK SIZE REINFORCING
8" (2)-#5 CONT.
TYPICAL CMU LINTEL
LIN
TE
L D
EP
TH
SE
E S
CH
ED
.
SEE
SCHED.
GROUT SOLID OVER FULL
LINTEL SPAN + BEARING
TY
P. W
AL
L
AB
OV
E
4'-0"
_<
LINTEL DEPTH
8"
_
REINFORCING
SEE SCHEDULE.
8" (2)-#5 CONT.6'-4"
_<
16"
_
TYPICAL WALL REINFORCING
AS REQ'D.
SCALE: 3/4" = 1'-0"
MASONRY LINTEL SCHEDULE
1
8"
(N
OM
.)
(4) CELLS
(4)-#6
GROUT SOLID - ALL CELLS. (TYP.)
GROUT SOLID - ALL CELLS. (TYP.)
(4) CELLS
(8)-#6
(2)-#6 @ 40"oc
BEYOND
12
"
(N
OM
.)
*INSIDE CORNERS SIMILAR
(3) CELLS
(3)-#6 BARS
(2
) C
EL
LS
(2
)-#
6 B
AR
S
(5) TOTAL BARS AT ALL CORNERS
(5) CELLS
(5)-#6 BARS
(2
) C
EL
LS
(2
)-#
6 B
AR
S
REINFORCING
AT INTERSECTION
(7) TOTAL BARS AT ALL CORNERS
REINFORCING
AT CORNER*
GROUT SOLID AT REINF. (TYP.)
SCALE: 3/4" = 1'-0"
ADDITIONAL REINFORCING AT CORNERS AND INTERSECTIONS
3
SCALE: 3/4" = 1'-0"
ADDITIONAL REINFORCING AT SHEARWALL CHORDS
4
MSW-2 - 8" CMU
MSW-1 - 12" CMU
(1)-#6 @ 40"oc
BEYOND
NOTE: AT 12" CMU - 2 BARS PER CELL
2'-6"
T
2T
ORNAMENTAL STAIRS
BY OTHERS. SEE ARCH.
1'-0"
(2) #5 CONT REBAR
#4 @ 24" O.C.
MIN
3
"
CL
R
CONC SLAB, SEE TYP
SLAB ON GRADE DETAIL
T.O. SLAB
SEE PLAN
SCALE: 3/4" = 1'-0"
THICKENED SLAB AT STAIR (TYP.)
5
(1) #4 EDGE BAR,
TYP
(1) #4 EDGE BAR,
TYP
#3 HOOKS @ 18"
O.C., TYP
(-3'-10")
T.O. FOOTING
(0'-0")
F.F.E.
SE
E A
RC
H
SLOPE-SEE ARCH
NOTE:
SEE ARCHITECTURALS FOR
SLOPE REQUIREMENTS OF 4"
SLAB ON GRADE AND TOP OF
PATIO EDGE ELEVATION.
SCALE: 3/4" = 1'-0"
TYPICAL EXTERIOR CMU PORCH WALL
6
#4 VERT. @ 24" O.C.
3"
#5 BARS TRANSVERSE @
18" O.C. TOP AND BOTTOM
3"
/////////////////// /////////////////////// ///////////////////
4" CONC. SLAB, REF
PLANS FOR DETAILS
LGS STUD WALL.
SEE PLAN.
BASE OF WALL TRACK. SEE
PLAN. ATTACH TO STUD w/ (2)
#10-16 SDS AND TO
CONCRETE w/ (2) PAFs AT
EACH STUD
1'-0"VAPOR BARRIER
1'-0
"
SCALE: 3/4" = 1'-0"
TYPICAL INTERIOR MEZZANINE WALL THICKENED SLAB
7
(2) #5 BARS
3"
6
"
M
I
N
8"
CONC. SLAB, SEE TYP
SLAB ON GRADE DETAIL
1/4" ISOLATION JOINT
#4 REBAR @ 12" O.C.
EACH WAY
#4 EDGE BAR, TYP
T.O. SLAB
SEE PLAN
T.O. SLAB
SEE PLAN
SCALE: 3/4" = 1'-0"
FOUNDATION SECTION AT CONCRETE STAIR
8
1/4" ISOLATION JOINT
#4 EDGE BAR, TYP
8"
4" SLAB-ON-GRADE, (TYP.)
SLOPE-SEE ARCH
SCALE: 3/4" = 1'-0"
TYP. INTERIOR WALL FOOTING TO PORCH SLAB TRANSITION
9
BRICK ROWLOCK COURSE.
SEE ARCH.
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
FO
UN
DA
TIO
N
DE
TA
ILS
HMH
HMH
HMH
S3.1
NOTES:
1. ELEVATED SLAB DESIGN ASSUMES DECKING IS INSTALLED IN
TYPICAL 3-SPAN CONFIGURATION. GC IS TO COORDINATE
INSTALLATION LAYOUT AS REQ'D.
2. ELEVATED SLAB IS DESIGNED AS COMPOSITE. SEE DETAIL 2/S4.0
FOR TYPICAL SHEAR STUD DETAIL AND ATTACHMENT.
4"
2VLI22 COMPOSITE FLOOR DECK
(TYP.) w/ HILTI X-ENP19 PAFs IN 36/4
PATTERN TO SUPPORTS. 1-1/2" TOP
ARC SEAM WELD SIDELAP
CONNECTIONS AT 24" O.C.
4" NW CONCRETE SLAB (TYP.)
SCALE: 3/4" = 1'-0"
TYPICAL ELEVATED SLAB
1
36/4 PATTERN
6x6-W1.4xW1.4 W.W.F.
1.5PLB22 ROOF DECK (TYP.).
FASTEN TO SUPPORTS IN 36/4
PATTERN w/ #12 TEK FASTENERS
& PUNCHLOK II SIDELAP
CONNECTIONS @ 24" O.C.
NOTES:
1. ELEVATED SLAB DESIGN ASSUMES DECKING IS INSTALLED IN
TYPICAL 3-SPAN CONFIGURATION. GC IS TO COORDINATE
INSTALLATION LAYOUT AS REQ'D.
1 1
/2
"
36/4 PATTERN
SCALE: 3/4" = 1'-0"
TYPICAL ROOF DECK
3
TYP
CANTILEVERED END
W-BEAM - SEE PLAN
SHEAR CONN. AS
REQ'D. (TYP.)
3/8"
CL
5'-0"
6'-0
"
1/4"
TYP
1/4"
TYP
3
8
" STIFFENER PLATE
3/8"
TYP
3/8"
TYP
SCALE: 3/4" = 1'-0"
TYP. KNEE BRACE CONNECTION
4
HSS 6x6x1/4 KNEE BRACE
10" MIN.
1
2
" THICK GUSSET PLATE
1
2
" THICK GUSSET PLATE
3/8" STIFFENER PLATE.
(REQUIRED FOR WIDE
FLANGE COLUMNS)
HSS COLUMN - SEE PLAN
*OPPOSITE HAND SIMILAR
WHERE APPLICABLE.
W-BEAM - SEE PLAN
THRU-PLATE SHEAR CONN. AS
REQ'D. (TYP.)
SCALE: 3/4" = 1'-0"
TYPICAL BEAM-COLUMN MOMENT CONNECTION-MC
6
CP
TYP
CP
TYP
SCALE: 3/4" = 1'-0"
5
MOMENT CONNECTION (MC)
SECTION - TYPICAL BEAM-GIRDER
W-BEAM - SEE PLAN
3/4" THICK A36
CAP PLATE
A
HSS COLUMN, SEE
PLAN.
2" 1'-0" 2"
2"
4"
2"
(4) 3/4" DIA.
A325 BOLTS
SECTION A
W-BEAM - SEE PLAN
T.O. STEEL
VARIES
TYPICAL COMPOSITE SLAB,
SEE DETAIL 1/S4.0
GUARDRAIL BY OTHERS. SEE
ARCHITECTURALS FOR SIZES
AND LOCATIONS.
SHEAR CONNECTION
AS REQUIRED
W-BEAM GIRDER - SEE PLAN
L4x4x5/16 CONT. EDGE
ANGLE (TYP.)
SCALE: 3/4" = 1'-0"
TYPICAL SLAB EDGE
7
1/4"
TYP
2 @ 12
1/4" BEAM WEB STIFFENER
EACH SIDE OF WEB. 8" HEIGHT.
8"
W-BEAM - SEE PLAN.
8" CONT. BOND BEAM COURSE
W/ (2) #5 AT JOIST BEARING
ELEVATION (TYP.)
8" OR 12" CMU BEARING
WALL - SEE PLAN
T.O. STEEL
VARIES-SEE PLAN
TYPICAL WALL REINF.
BEYOND - SEE DETAIL
2"
L4x4x5/16 CONT. ALONG ENTIRE LENGTH
OF CMU WALL (ORIENTED AS SHOWN) W/
1/2"Ø HILTI HUS-EZ ANCHORS (4 1/4" MIN.
EMBED) @ 8" O.C. & 1/2" HEADED STUDS x
4"L & 8" O.C. ANCHORS ARE TO BE
CENTERED IN GROUTED CELLS - STAGGER
HEADED STUDS AS REQ'D. (TYP. EA. SIDE).
EMBED
GR
OU
T S
OL
ID
(3
)-C
OU
RS
ES
(C
ON
T.)
8" (M
IN
.)
8" (M
IN
.)
4 1/4" (MIN.)
3/8" MIN. THICK DOUBLE ANGLE CONNECTION
TO W-BEAM. 4-1/2" MIN. LEG SIZE TO CMU.
(4) 5/8" DIA. HILTI KWIK HUS-EZ ANCHORS.
5" MIN. EMBEDMENT.
5" (M
IN
.)
6" (MIN.)
5" MIN. EMBED
FACE OF BEAM CONNECTION
NOTE:
DO NOT PLACE ANCHORS w/IN
1.1/4" OF CMU HEAD JOINT.
MAINTAIN MINIMUM EDGE
DISTANCES TO TOP/ BOTTOM
OF SOLID GROUTED CMU
BOND BEAM AS SHOWN.
SCALE: 3/4" = 1'-0"
SINGLE W-BEAM BEARING AT SHEARWALL
8
4-1/2" MIN.
STEEL BEAM, SEE PLAN
6-1/2" x 3/8" x 6-1/2" BEARING
PLATE w/ (2) 1/2" x 5" HIGH
STRENGTH ANCHORS
COPE BOTTOM FLANGE AS
NEEDED FOR KEEPER PLATES
WHEN SLIP JOINT IS REQUIRED
PARALLEL
BEARING
NOTES:
1. GROUT ALL HATCHED AREAS IN ADDITION TO VERTICAL REINFORCED CELLS.
2. PROVIDE SLIP BEARING WITH 2" x 3/16" x 4" KEEPER PLATE AT MASONRY OPENINGS GREATER THAN 10'-0". WELD KEEPER PLATES TO
BEARING PLATE, DO NOT WELD KEEPER TO BEAM FLANGE NOR BEAM FLANGE TO BEARING. GREASE BOTTOM OF BEAM FOR SLIPPAGE.
KEEPER PLATES WHEN
REQUIRED, SEE NOTE 2
STEEL BEAM, SEE PLAN, STOP
END OF BEAM 2" FROM OPPOSITE
SIDE OF PERPENDICULAR CMU
6-1/2" x 3/8" x 1'-2" BEARING
PLATE w/ (2) 1/2" x 5" HIGH
STRENGTH ANCHORS
PERPENDICULAR
BEARING
2' G
RO
UT
KEEPER PLATES WHEN
REQUIRED, SEE NOTE 2
2'-0" BOND BEAM 2'-0" BOND BEAM
VERT WALL BARS, (2) EACH
CELL, (1) EACH FACE
3/16"
1/4"
SCALE 3/4" = 1'-0"
TYP. STEEL BEAM BEARING ON CMU WALL DETAIL (HOIST BEAM)
9
4"
4"
7 1/4" 4 3/4" 7 1/4" 4 3/4" 7 1/4"
4 3/4"
3/4"
MIN
3/4"
MIN
1"
MIN
1'-0"
DECK RIBS
B.O. DECK
RIB
B.O. DECK
RIB
FL
AN
GE
WID
TH
1"
MIN
3/4"
MIN
3/4"
MIN
EQ
EQ
3"
MIN
COMPOSITE DECK
3/4"Øx3"L HEADED
STUD (TYP.)
BEAM FLANGE
TYPICAL ORIENTATION
OF 2 STUDS PER RIN
TYPICAL ORIENTATION
OF 1 STUD PER RIN
SECTION
PLAN
SCALE: 1-1/2" = 1'-0"
TYPICAL COMPOSITE SLAB STUD PLACEMENT
2
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
FR
AM
IN
G
DE
TA
ILS
HMH
HMH
HMH
S4.0
/ / / / / / / /
CL
T.O.C.
SEE PLAN
SCALE: 3/4" = 1'-0"
TYPICAL SLAB AT DECK CHANGE
11
STEEL BEAM. SEE PLAN.
CONT. 16GA GIRDER FLASH
WHERE REQUIRED BY
SUPPLIER
CELL CLOSURE
COMPOSITE DECK, REF PLAN
FOR REQUIREMENTS
SEE ARCH.
C
L
W-BEAM - SEE PLAN.
TYPICAL COMPOSITE SLAB
SEE DETAILS 1/S3.0
L4x4x5/16" CONT. EDGE
ANGLE (TYP.)
L3x3x1/4 DIAGONAL BRACE AS
SHOWN @ 4'-0" MAX. O.C. (TYPICAL)
W-BEAM -
SEE PLAN.
1/4"
TYP
LGS FRAMING BY
SUBCONTRACTOR. PROVIDE 3/4"
DEFL. GAP @ CONNECTION TO
STEEL (TYP.)
C
L
SCALE: 3/4" = 1'-0"
TYPICAL EXTERIOR SLAB EDGE
12
0.6C26 METAL DECK (TYP.)
FASTEN TO SUPPORTS IN 36/4
PATTERN w/ #12 TEK FASTENERS
& #10 TEK FASTENER SIDELAP
CONNECTIONS @ 24" O.C.
NOTES:
1. ELEVATED SLAB DESIGN ASSUMES DECKING IS INSTALLED IN
TYPICAL 3-SPAN CONFIGURATION. GC IS TO COORDINATE
INSTALLATION LAYOUT AS REQ'D.
1 5
/8
"
36/4 PATTERN
SCALE: 3/4" = 1'-0"
TYPICAL MECHANICAL MEZZANINE DECK
13
NONSTRUCTURAL TOPPING SLAB
CL CL
T.O.S.
33'-8"
T.O.C.
30'-3"
PRE-FABRICTED LGS TRUSS BY
MANUFACTURER.
1.5 ROOF DECK - SEE PLAN.
ROOFING - SEE ARCH.ELEVATED TRUSS BEARING SEAT, TO
BEAR AT ROOF ELEVATION AS SHOWN.
SEE PLAN FOR T.O.S.
HOLDOWN CONNECTION BY TRUSS
MANUFACTURER, TO MATCH
ULTIMATE/ PROPRIETARY CHORD
PROFILE, TYP. SEE WIND LOAD
INFORMATION ON PLAN, TYP.
W-BEAM
SEE PLAN.
1/4" GUSSET @ 4'-0"oc
(TYP. AT TRUSS BEARING)
3/8" CONTINUOUS PLATE - MATCH
PRIMARY STEEL T.O.S. ELEVATION.
7 1/2"
W-BEAM - SEE PLAN.
REF. 12/S4.1 FOR TYPICAL KICKER
BRACING AT PERIMETER W-BEAM.
ELEVATED SLAB - SEE PLAN.
GUARDRAIL ASSEMBLY BY OTHERS - SEE ARCH.
GUARDRAIL TO ANCHOR DIRECTLY TO SLAB.
SEE
ARCH
LGS WALL BELOW - SEE PLAN.
CL CL
T.O.S.
33'-8"
T.O.C.
30'-3"
LGS INFILL TO ACCOMMODATE
BALCONY PROFILE
EXTENT OF TRUSS PROFILE BEYOND.
W-BEAM
SEE PLAN.
ELEVATED SLAB.
SEE PLAN.
LGS WALL BELOW - SEE PLAN.
SCALE: 3/4" = 1'-0"
SECTION - ROOF BALCONY
16
HSS6x6x1/4
3'-8"
C6x8.2 CHANNEL HANGER
A
A
ROOF PLANE BEYOND
C6x8.2 HANGER (LGS INFILL BEYOND)
GUARDRAIL ASSEMBLY BY OTHERS - SEE ARCH.
GUARDRAIL TO ANCHOR DIRECTLY TO SLAB.
SECTION A-A
(2)-L3X3X1/4" KICKER w/
1/4" (MIN.) GUSSET
3/8" STIFFENER PLATE CENTERED ABOVE
HANGER CONNECTION, (EA. SIDE)
CL
4'-0"
4'-0
"
1/4"
TYP
1/4"
TYP
3
8
" STIFFENER PLATE
3/8"
TYP
3/8"
TYP
SCALE: 3/4" = 1'-0"
TYP. HIGH ROOF KNEE BRACE CONNECTION
14
HSS 6x6x1/4 KNEE BRACE
10" MIN.
1
2
" THICK GUSSET PLATE
1
2
" THICK GUSSET PLATE
4"
4"
10
" M
IN
.
SCALE: 3/4" = 1'-0"
TYPICAL TRUSS BEARING
15
W-BEAM
SEE PLAN.
W-BEAM - SEE PLAN
T.O. STEEL
SEE PLAN
TYPICAL COMPOSITE SLAB,
SEE DETAIL 1/S4.0
W-BEAM GIRDER - SEE PLAN
WT-SHIM AS REQUIRED TO
ALLOW BEARING ON
GIRDER BELOW
W-BEAM - SEE PLAN
T.O. STEEL
SEE PLAN
SCALE: 3/4" = 1'-0"
SECTION - TYPICAL BEAM BEARING ON GIRDER
17
3/8" WEB STIFFENER EACH SIDE
OF GIRDER WEB, CENTERED
BELOW EACH SEATED BEAM
BEARING ABOVE
3/8" WEB STIFFENER EACH SIDE
OF EACH W24xXX, CENTERED
ABOVE GIRDER BEAM WEB BELOW
W-BEAM
SEE PLAN.
VERT WALL BARS TO MATCH TYP. WALL
REINF (2) EACH CELL, (1) EACH FACE MIN.
STEEL BEAM & PLATE,
SEE PLAN AND SECTION
3/8"x7"x7"
BEARING PLATE
CONT. 'KNOCK-OUT' BLOCK BOND BEAM
w/ (2) #5 CONT. FILL w/ GROUT CONT.
ABOVE STEEL BEAM
3/4"dia x 4'-0" DBA ANCHOR,
SPACING & ALIGNMENT TO
MATCH WALL VERT REBAR,
WELD TO BEAM
GR
OU
T S
OL
ID
24
" A
BO
VE
L
IN
TE
L
VERT WALL BARS, SEE
SCHEDULE FOR SIZE,
SPACING, AND LOCATIONS
BOND BEAM
w/ (2) #5
1/2"
2'-0" MIN
1/4" 5"
1/4" 5"
STEEL BEAM BEARING
7"
TOP VIEW - BEARING
3/4"
TYP
3/8" THICK BEARING PLATE w/
(2) 3/4" DIA. x 48" DBA ANCHOR
1/4" FINISH PLATE
EXTEND ONLY TO
EDGE OF OPENING
SECTION VIEW
1/4" 2@8
TYP
MASONRY SOAPS
7"
SCALE: 1/2" = 1'-0"
TYP. BEAM BEARING AT CMU WALL CORNERS
10
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mo
n law
, statu
tory a
nd oth
er reserved
rights inclu
ding the
copyright the
reto.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
FR
AM
IN
G
DE
TA
ILS
HMH
HMH
HMH
S4.1
T.O. STEEL
SEE PLAN
LGS WALL BELOW
- SEE PLAN.
1200S162-54 JOISTS @ 24"
O.C. MAX.
0.6C26 METAL DECK w/ NON
STRUCTURAL TOPPING SLAB.
SEE DETAIL 13/S4.1.
STEEL BEAM FRAMING -
SEE PLAN.
TYPICAL COMPOSITE SLAB,
SEE DETAIL 1/S4.0
SCALE: 3/4" = 1'-0"
TYP. RAISED BAR FLOOR
18
STIFFCLIP AL600 w/ (4)
#12-14 SDS TO JOIST AND
(2) PAFs TO CONCRETE @
4'-0" O.C. MAX.
ROOFING INSULATION AND
MEMBRANE - SEE ARCH
WALKABLE ROOFING FINISH
- SEE ARCH
STEEL BEAM FRAMING -
SEE PLAN.
CL
6" HSS COLUMN. SEE PLAN.
SCALE: 3/4" = 1'-0"
TYP. HIGH ROOF 6" TO 8" COLUMN CONNECTION
19
8" HSS COLUMN. SEE PLAN.
STEEL BEAM. SEE PLAN.
SEE PLAN
T.O. STEEL
1/4"
TYP
3/8" MIN. THICKNESS CAP PLATE
CJP - CAP PLATE
TO COLUMN
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mo
n law
, statu
tory a
nd oth
er reserved
rights inclu
ding the
copyright the
reto.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
FR
AM
IN
G
DE
TA
ILS
HMH
HMH
HMH
S4.2
JA
MB
H
EIG
HT
(S
EE
S
CH
ED
UL
E)
JAMB TO HEAD CONNECTION,
SEE SCHEDULE
JAMB TO HEADER CONNECTION
USING STIFFCLIP AL BY TSN,
SEE SCHEDULE
LGS BOX HEADER, SEE
SCHEDULE
WIN
DO
W H
EIG
HT
(M
AX
.)
SE
E T
AB
LE
WIDTH (MAX.)
SEE TABLE
BOTTOM TRACK, SEE TYP.
WALL SECTION
JAMB TO BASE CONNECTION,
SEE SCHEDULE
TOP TRACK, SEE TYP.
WALL SECTIONS
JAMB, SEE SCHEDULE
CRIPPLE STUDS TO MATCH
ADJACENT WALL STUDS
SCALE: 3/4" = 1'-0"
OPENING FRAMING ELEVATION - WINDOWS
---
SIL
L H
EIG
HT
(M
AX
.)
SE
E T
AB
LE
JAMB TO SILL CONNECTION,
SEE SCHEDULE
LGS SILL, SEE SCHEDULE
JA
MB
H
EIG
HT
(S
EE
S
CH
ED
UL
E)
JAMB TO HEAD CONNECTION,
SEE SCHEDULE
JAMB TO HEADER CONNECTION
USING STIFFCLIP AL BY TSN,
SEE SCHEDULE
LGS BOX HEADER, SEE
SCHEDULE
HE
IG
HT
(M
AX
.)
SE
E T
AB
LE
WIDTH (MAX.)
SEE TABLE
BOTTOM TRACK, SEE TYP.
WALL SECTION
JAMB TO BASE CONNECTION,
SEE SCHEDULE
TOP TRACK, SEE TYP.
WALL SECTIONS
JAMB, SEE SCHEDULE
CRIPPLE STUDS TO MATCH
ADJACENT WALL STUDS
STEEL BEAM AND
CONCRETE SLAB
SCALE: 3/4" = 1'-0"
OPENING FRAMING ELEVATION - DOORS
---
STEEL BEAM AND
CONCRETE SLAB
WINDOW SCHEDULE
MARK
JAMB
HEIGHT
(MAX.)
WINDOW
WIDTH
(MAX.)
WINDOW
HEIGHT
(MAX.)
SILL
HEIGHT
(MAX.)
JAMB SECTION HEADER SECTION SILL SECTION
JAMB SECTION JAMB TO BASE JAMB TO HEAD HEADER SECTION HEADER TO JAMB SILL SECTION SILL TO JAMB
H4A 16'-4" 6'-8" 2'-4" 5'-0"
(2) 600S350-68 [50] BTB +
(1) 600T200-68 [50]
STIFFCLIP CL362-68 BY TSN,
(6) #12-14 SDS TO STUD, (1)
1/2" F1554 GR. 36 ROD w/
SET-3G (4" EMBED) TO
CONCRETE w/ 4.25" EDGE
DISTANCE
VERTICLIP SL600 BY TSN, (2)
#12-14 SDS TO STUD, (2) PAF
TO STEEL BEAM
BOX: (2) 600S162-43 [33] +
(2) 600T125-43 [33]
(2) STIFFCLIP AL600 BY TSN,
(2) #12-14 SDS EA. LEG
600T125-54 [50]
STIFFCLIP AL600 BY TSN, (2)
#12-14 SDS TO STUD, (2)
#12-14 SDS TO JAMB
DOOR SCHEDULE
MARK
JAMB
HEIGHT
(MAX.)
DOOR
WIDTH
(MAX.)
DOOR
HEIGHT
(MAX.)
JAMB SECTION HEADER SECTION
JAMB SECTION JAMB TO BASE JAMB TO HEAD HEADER SECTION HEADER TO JAMB
H1A 15'-4" 3'-8" 8'-4"
(1) 600S350-97 [50]
STIFFCLIP CL362-68 BY TSN, (6)
#12-14 SDS TO STUD, (1) 1/2"
F1554 GR. 36 ROD w/ SET-3G (4"
EMBED) TO CONCRETE w/ 4.25"
EDGE DISTANCE
VERTICLIP SL600 BY TSN, (3)
#12-14 SDS TO STUD, (2) PAF
TO STEEL BEAM
BOX: (2) 600S162-54 [50] +
(2) 600T125-54 [50]
(2) STIFFCLIP AL600 BY
TSN w/ (4) #12-14 SDS EA.
LEG
H1B 16'-6" 3'-8" 8'-4"
(1) 600S350-97 [50] +
(1) 600T200-97 [50]
STIFFCLIP CL362-68 BY TSN, (2)
#12-14 SDS TO STUD, (1) 1/2"
F1554 GR. 36 ROD w/ SET-3G (2.75"
EMBED) TO CONCRETE w/ 4.25"
EDGE DISTANCE
VERTICLIP SL600 BY TSN, (3)
#12-14 SDS TO STUD, (2) PAF
TO STEEL BEAM
BOX: (2) 600S162-43 [33] +
(2) 600T125-43 [33]
(2) STIFFCLIP AL600 BY
TSN w/ (4) #12-14 SDS EA.
LEG
H2 15'-4" 13'-0" 8'-4"
(2) 600S350-97 [50] +
(2) 600T200-97 [50]
STIFFCLIP CL362-68 BY TSN, (6)
#12-14 SDS TO STUD, (1) 1/2"
F1554 GR. 36 ROD w/ SET-3G (4"
EMBED) TO CONCRETE w/ 4.25"
EDGE DISTANCE
(2) VERTICLIP SL600 BY TSN, (3)
#12-14 SDS TO STUD, (2) PAF
TO STEEL BEAM
BOX: (2) 362S162-97 [50] +
(2) 600T200-97 [50]
(2) STIFFCLIP AL600 BY
TSN, (4) #12-14 SDS EA.
LEG
H3 16'-4" 13'-0" 9'-0"
(2) 600S350-97 [50] +
(2) 600T200-97 [50]
STIFFCLIP CL362-68 BY TSN, (6)
#12-14 SDS TO STUD, (1) 1/2"
F1554 GR. 36 ROD w/ SET-3G (2.75"
EMBED) TO CONCRETE w/ 4.25"
EDGE DISTANCE
VERTICLIP SL600 BY TSN, (3)
#12-14 SDS TO STUD, (3) PAF
TO STEEL BEAM
BOX: (2) 600S162-54 [50] +
(2) 600T200-97 [50]
(2) STIFFCLIP AL600 BY
TSN, (4) #12-14 SDS EA.
LEG
H5 13'-0" 13'-0" 7'-4"
(2) 600S350-68 [50] +
(1) 600T200-68 [50]
STIFFCLIP CL362-68 BY TSN, (6)
#12-14 SDS TO STUD, (1) 1/2"
F1554 GR. 36 ROD w/ SET-3G (2.75"
EMBED) TO CONCRETE w/ 4.25"
EDGE DISTANCE
VERTICLIP SL600 BY TSN, (3)
#12-14 SDS TO STUD, (3) PAF
TO STEEL BEAM
BOX: (2) 600S162-54 [50] +
(2) 600T200-97 [50]
(2) STIFFCLIP AL600 BY
TSN, (4) #12-14 SDS EA.
LEG
H6 13'-0" 6'-9" 7'-4"
600S350-97 [50]
STIFFCLIP CL362-68 BY TSN, (6)
#12-14 SDS TO STUD, (1) 1/2"
F1554 GR. 36 ROD w/ SET-3G (2.75"
EMBED) TO CONCRETE w/ 4.25"
EDGE DISTANCE
VERTICLIP SL600 BY TSN, (3)
#12-14 SDS TO STUD, (3) PAF
TO STEEL BEAM
BOX: (2) 600S162-43 [33] +
(2) 600T125-43 [33]
(2) STIFFCLIP AL600 BY
TSN, (4) #12-14 SDS EA.
LEG
H7 13'-0" 3'-4" 7'-4"
600S300-97 [50]
STIFFCLIP CL362-68 BY TSN, (6)
#12-14 SDS TO STUD, (1) 1/2"
F1554 GR. 36 ROD w/ SET-3G (2.75"
EMBED) TO CONCRETE w/ 4.25"
EDGE DISTANCE
VERTICLIP SL600 BY TSN, (3)
#12-14 SDS TO STUD, (3) PAF
TO STEEL BEAM
BOX: (2) 600S162-43 [33] +
(2) 600T125-43 [33]
(2) STIFFCLIP AL600 BY
TSN, (4) #12-14 SDS EA.
LEG
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
LG
S O
PE
NIN
G
ELE
VA
TIO
NS
HMH
HMH
HMH
S5.0
JA
MB
H
EIG
HT
(S
EE
S
CH
ED
UL
E)
JAMB TO HEAD CONNECTION,
SEE SCHEDULE
JAMB TO HEADER CONNECTION.
SEE SCHEDULE.
LGS BOX HEADER, SEE
SCHEDULE
HE
IG
HT
(M
AX
.)
SE
E T
AB
LE
WIDTH (MAX.)
SEE TABLE
BOTTOM TRACK, SEE TYP.
WALL SECTION
JAMB TO BASE CONNECTION,
SEE SCHEDULE
TOP TRACK, SEE TYP.
WALL SECTIONS
JAMB, SEE SCHEDULE
CRIPPLE STUDS TO MATCH
ADJACENT WALL STUDS
STRUCTURE ABOVE.
SEE PLAN.
SCALE: 3/4" = 1'-0"
OPENING FRAMING ELEVATION - MEZZANINE WALL DOORS
---
DOOR SCHEDULE
MARK
JAMB
HEIGHT
(MAX.)
DOOR
WIDTH
(MAX.)
DOOR
HEIGHT
(MAX.)
JAMB SECTION HEADER SECTION
JAMB SECTION JAMB TO BASE JAMB TO HEAD HEADER SECTION HEADER TO JAMB
H8 16'-8" 3'-4" 7'-2"
362S162-97 [50]
STIFFCLIP AL362 w/ (2) #12-14
SDS TO JAMB AND (2) 1/4"x1-1/4"
HILTI KWIK CON II+ (2" MIN.
SPACING)
VERTICLIP SL362 BY TSN w/ (2)
#12-14 SDS TO JAMB & (2) PAFs
TO STEEL BEAM OR (2) 1/4"x1-1/4"
HILTI KWIK CON II+ TO
CONCRETE (2" MIN. SPACING)
BOX: (2) 362S162-54 [50] +
(2) 362T125-54 [50]
(2) STIFFCLIP AL362 BY
TSN w/ (4) #12-14 SDS EA.
LEG
H9 16'-8" 3'-4" 7'-2"
(1) 362S300-97 [50] +
(1) 362T200-97 [50]
STIFFCLIP AL362 w/ (2) #12-14
SDS TO JAMB AND (2) 1/4"x1-1/4"
HILTI KWIK CON II+ (2" MIN.
SPACING)
VERTICLIP SL362 BY TSN w/ (2)
#12-14 SDS TO JAMB & (2) PAFs
TO STEEL BEAM OR (2) 1/4"x1-1/4"
HILTI KWIK CON II+ TO
CONCRETE (2" MIN. SPACING)
BOX: (2) 362S162-68 [50] +
(2) 362T125-68 [50]
(2) STIFFCLIP AL362 BY
TSN w/ (4) #12-14 SDS EA.
LEG
H10 16'-8" 3'-4" 7'-2"
(1) 600S300-54 [50]
STIFFCLIP AL600 w/ (2) #12-14
SDS TO JAMB AND (2) 1/4"x1-1/4"
HILTI KWIK CON II+ (2" MIN.
SPACING)
VERTICLIP SL600 BY TSN w/ (2)
#12-14 SDS TO JAMB & (2) PAFs
TO STEEL BEAM OR (2) 1/4"x1-1/4"
HILTI KWIK CON II+ TO
CONCRETE (2" MIN. SPACING)
BOX: (2) 362S162-54 [50] +
(2) 600T125-54 [50]
(2) STIFFCLIP AL600 BY
TSN w/ (4) #12-14 SDS EA.
LEG
H11 16'-8" 6'-4" 7'-2"
(1) 600S350-54 [50]
STIFFCLIP AL600 w/ (2) #12-14
SDS TO JAMB AND (2) 1/4"x1-1/4"
HILTI KWIK CON II+ (2" MIN.
SPACING)
VERTICLIP SL600 BY TSN w/ (2)
#12-14 SDS TO JAMB & (2) PAFs
TO STEEL BEAM OR (2) 1/4"x1-1/4"
HILTI KWIK CON II+ TO
CONCRETE (2" MIN. SPACING)
BOX: (2) 362S200-97 [50] +
(2) 600T125-97 [50]
STIFFCLIP HE(S)-68 BY
TSN w/ (4) #10-16 SDS
HORIZONTAL / (8) #10-16
SDS VERTICAL PATTERN
DESIGNED BY:
DRAWN BY:
APPROVED BY:
PROJECT #:
DATE:
No. Revision Date
Sheet
Ow
nership of Instrum
ents of S
ervice: A
ll reports, plans, specifications, com
puter files, field data, notes and instrum
ents prepared by the design professional as instrum
ents of service shall rem
ain the property of the design professional. A
ll com
mon
la
w, statuto
ry an
d o
the
r re
se
rved rig
hts in
clud
in
g th
e cop
yrig
ht thereto
.
Sheet T
itle
Project N
am
e
CLU
BH
OU
SE
MO
RE
HE
AD
C
IT
Y, N
OR
TH
C
AR
OLIN
A
MO
RE
HE
AD
C
IT
Y C
OU
NT
RY
C
LU
B
20-254
01/29/2021
LG
S O
PE
NIN
G
ELE
VA
TIO
NS
HMH
HMH
HMH
S5.1