30). SDI DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS (PUBLICATION No. AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, ALLOWABLE STRESS DESIGN. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY. 2018 NORTH CAROLINA STATE BUILDING CODE. DESIGN CODES: AND GENERAL NOTES SUCH AS 'DIMENSIONS CORRECTED' ARE NOT ACCEPTABLE. AND DESCRIPTIONS OF ALL CHANGES MADE FROM PREVIOUS SUBMITTAL. LIST SHALL BE SPECIFIC 6. ALL SHOP DRAWING RESUBMITTALS SHALL INCLUDE A WRITTEN DETAILED LIST OF LOCATIONS APPROVAL. ALL PERSONNEL DEEMED NECESSARY BY CONTRACTOR PRIOR TO SUBMITTAL TO ENGINEER FOR 5. ALL STRUCTURAL SHOP DRAWINGS TO BE REVIEWED BY JOB SUPERINTENDENT IN ADDITION TO EXPENSE OF THE CONTRACTOR. ADDITIONAL OBSERVATIONS DUE TO THE DEFICIENCIES IN WORK OBSERVED WILL BE AT THE 4. ADDITIONAL OBSERVATIONS AS A RESULT OF REJECTION OF WORK COMPLETED AND/OR TEMPORARY BRACING (AND ACCOMPANYING FOOTINGS), GUYS OR TIEDOWNS. DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION 3. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK. DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER 2. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD AND WITH ALL OTHER DRAWINGS. DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT THESE 1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND GENERAL NOTES: STRUCTURAL NOTES PERMANENTLY EXPOSED TO EXTERIOR. SHALL BE A36 THREADED ROD. PROVIDE HOT DIP GALVANIZE FINISH ON ALL ANCHOR BOLTS ANCHOR BOLTS: MANUFACTURER'S REPRESENTATIVE. ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. INSTALLERS SHALL BE TRAINED BY THE SIKA "SIKADUR INJECTION SEL", "HILTI-HIGH STRENGTH EPOXY", OR APPROVED EQUAL, INSTALLED IN SHALL BE A POLYMER INJECTION SYSTEM SUCH AS RAMSET "EPCON", MOLLY "PARAMOUNT HVC", CHEMICAL ANCHORS: LOCATIONS AND SIZES SHALL BE APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. OR 6" CLEAR BETWEEN SLEEVES, WHICHEVER IS GREATER. PRIOR TO CONSTRUCTION SLEEVE MINIMUM SLEEVE SPACING SHALL BE TWO DIAMETERS CENTER TO CENTER TO THE LARGER SLEEVE PLUMBING SLEEVES: ON GRANULAR ENGINEERED FILL MATERIAL. REPORT FOR ALL REQUIREMENTS RELATED TO THE CONSTRUCTION OF THE SLAB AND FOOTINGS 3. DESIGNS BASED UPON AN ALLOWABLE BEARING CAPACITY OF 2,000 psf. SEE GEOTECHNICAL CODES SECTION OF THESE STRUCTURAL NOTES. REPORT FOR THE LOADS PRESCRIBED BY THE BUILDING CODE REFERENCED IN THE DESIGN DESIGNS WERE BASED UPON STAYING WITHIN THE LIMITS GIVEN WITHIN THE GEOTECHNICAL BUILDING TYPE IS THE RESPONSIBILITY OF THE GEOTECHNICAL ENGINEER. ALL STRUCTURAL CONSTRUCTION DOCUMENTS. DETERMINING THE AMOUNT OF SETTLEMENT ACCEPTABLE FOR THE SPECIFIC BUILDING TYPE, CONSTRUCTION TYPE, AND LIKELY LOADS SHOWN ON THE 2. GEOTECHNICAL RECOMMENDATIONS WERE PREPARED WITH SPECIFIC KNOWLEDGE OF THE JULY 28, 2020 DATE: - ECS PROJECT No. 22:29313 MOREHEAD CITY, CARTERET COUNTY, NORTH CAROLINA MOREHEAD CITY COUNTRY CLUB GEOTECHNICAL ENGINEERING REPORT TITLE: - PREPARED BY: ECS SOUTHEAST, LLP - FOLLOWING: INSTALLATION PROCEDURES. SITE PREPARATION AND FOUNDATION SHALL COMPLY WITH THE 1. SEE THE FOLLOWING REPORT FOR COMPLETE GEOTECHNICAL RECOMMENDATIONS AND FOUNDATIONS: REQUIREMENTS SET FORTH IN ACI STANDARDS 301 AND 347. REMOVAL OF ALL FORMWORK, SHORES AND RESHORES SHALL MEET THE LEAST TWO-THIRDS OF THE 28 DAY DESIGN STRENGTH. DESIGN, ERECTION AND NO STRUCTURAL CONCRETE SHALL BE STRIPPED UNTIL IT HAS REACHED AT FORMWORK AND SHORING: DISCRETION. ADDITIONAL #4 & #5 REINFORCING STEEL TO BE USED AT ENGINEER'S 12. CONTRACTOR TO FURNISH AND INSTALL 500 LINEAR FT. EACH OF (CURRENT EDITIONS), RESPECTIVELY, SHALL BE MAINTAINED. 11. COLD WEATHER AND HOT WEATHER PROVISIONS OF ACI 306 AND 305 ENGINEER FOR ALL OPENINGS GREATER THAN 12"x12" FOR DESIGN. EXTEND REINFORCING 2'-0" BEYOND OPENING IN BOTH DIRECTIONS. CONTACT AROUND ALL OPENINGS GREATER THAN 12"x12" IN CAST-IN-PLACE CONCRETE. 10. PROVIDE TWO (2) #5'S, ONE AT EACH FACE, UNLESS NOTED OTHERWISE, 1 1/2" BEAMS AND COLUMNS 1 1/2" #14 AND #18 3/4" #11 BARS OR SMALLER AND WALLS OR IN CONTACT WITH THE GROUND, SLABS NOT EXPOSED TO EARTH OR WEATHER 1 1/2" #5 BARS OR SMALLER 2" #6 THROUGH #18 BARS EXPOSED TO EARTH OR WEATHER EXPOSED TO EARTH 3" CAST AGAINST AND PERMANENTLY MINIMUM COVER DESCRIPTION 9. REINFORCING STEEL SHALL RECEIVE CONCRETE COVER AS FOLLOWS: THEM. THEM. CLIP ANGLES SHALL BE FURNISHED BY THE CONTRACTOR REQUIRING THEM AND INSTALLED BY THE CONTRACTOR CASTING THE CONCRETE AROUND CONCRETE INSERTS SHALL BE FURNISHED BY THE CONTRACTOR REQUIRING OR CONCRETE INSERTS FOR FASTENING AND SECURING OTHER COMPONENTS. 8. WHERE SHOWN ON THE DRAWINGS, PROVIDE WELD PLATES, WELDMENTS, REINFORCING. THE FOOTINGS WITH SAME SIZE AND QUANTITY DOWEL AS THE VERTICAL AND PIERS, OR VERTICAL REINFORCING IN WALLS, SHALL BE DOWELED INTO 4, UNLESS OTHERWISE NOTED. ALL VERTICAL REINFORCING STEEL IN COLUMNS 7. PROVIDE FOUNDATION DOWELS AS SHOWN. MINIMUM SIZE DOWELS TO BE # CORNER BARS, UNLESS NOTED OTHERWISE. WALL, BEAM OR FOOTING. PROVIDE MINIMUM OF 40 BAR DIAMETER LAP FOR ALL 6. PROVIDE CORNER BARS OF SAME BAR DIAMETER AS SPECIFIED FOR THE ON DRAWINGS (CLASS B SPLICE). DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER, UNLESS NOTE OTHERWISE 5. LAP ALL REINFORCING SPLICES IN CONCRETE A MINIMUM OF 48 BAR ACCORDANCE WITH THE LATEST ACI MANUALS. 4. ALL REINFORCING STEEL BARS TO BE DETAILED AND PLACED IN LAPS SHALL BE ONE SPACE PLUS 2". PLACING DETAILS OF ACI STANDARDS AND THE SPECIFICATIONS. MINIMUM FROM OIL, SCALE AND RUST. PLACE WWF IN ACCORDANCE WITH THE TYPICAL 3. WELDED WIRE FABRIC TO CONFORM TO ASTM A185 AND SHALL BE FREE EXCEPT WHERE NOTED OTHERWISE. REINFORCING SHALL NOT BE WELDED. 2. ALL REINFORCING STEEL TO BE ASTM A615, GRADE 60 (#4 AND LARGER), STRAIGHTEDGE AND THE FLOOR SHALL NOT EXCEED 1/4". SLAB CONCRETE PLACEMENT. THE GAP AT ANY POINT BETWEEN THE ALLOWING IT TO REST UPON TWO HIGH SPOTS WITHIN 28 DAYS AFTER (UNLEVELED) 10 FT. STRAIGHTEDGE ANYWHERE ON THE SLAB AND FLOOR FINISH TOLERANCES AS MEASURED BY PLACING A FREESTANDING ACI 117 ITEM 4.5.7 3/8" ENVELOPE EITHER SIDE OF THE THEORETICAL DESIGN SURFACE. ELEVATIONS OF SLABS-ON-GRADE TOP OF SLAB ELEVATION SHALL BE WITHIN A ACI 117 ITEM 4.3.1.1 EXCEPT AS MODIFIED BELOW: 1. ALL CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 301 AND ACI 117 CONCRETE AND REINFORCING PLACEMENT: SLABS SHALL NOT EXCEED 3%. INCLUDE AN AIR-ENTRAINING ADMIXTURE; THE MAXIMUM AIR CONTENT IN THESE 8. CONCRETE FOR TROWEL-FINISHED INTERIOR CONCRETE FLOORS SHALL NOT ENGINEER'S WRITTEN PERMISSION FOR THEIR USE. 7. NO SALTS OF ANY KIND MAY BE USED IN CONCRETE BEFORE OBTAINING THE PERMISSION OF THE ENGINEER IS GIVEN. PLASTICIZERS AND SUPER-PLASTICIZERS MAY BE USED ONLY WHEN WRITTEN 6. WATER REDUCING AGENTS MAY BE USED IN THE CONCRETE MIX. TO 5% TO 7 %. 5. ALL CONCRETE EXPOSED TO WEATHER OR EARTH SHALL BE AIR ENTRAINED THAN SPECIFIED. TO RECEIVE SPECIAL CURING IF THE COMPRESSIVE STRENGTHS ARE LESS SHALL DETERMINE IF THE CONCRETE IS ACCEPTABLE, OR TO BE REMOVED, OR SPECIFICATIONS ARE MINIMUM COMPRESSIVE STRENGTHS. THE ENGINEER 4. THE CONCRETE STRENGTHS SHOWN IN THE SECTION ABOVE AND IN THE BY THE GEOTECHNICAL ENGINEER OR GEOTECHNICAL REPORT. 3. CONCRETE SHALL UTILIZE TYPE I/II CEMENT UNLESS OTHERWISE DIRECTED WITH THE APPROVAL OF THE ENGINEER. CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY AREAS IN THE CURING MEMBRANE SHALL BE RECOATED DAILY. CALCIUM THE WATER HAS LEFT THE UNFINISHED CONCRETE. ALL SCUFFED OR BROKEN SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS STANDARD C309 TYPE 1 AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND ABOVE. ALL SLABS SHALL BE CURED USING CURING COMPOUND MEETING ASTM REPRESENTATIVE AND THE CONTRACTOR OF ANY NONCOMPLIANCE WITH THE SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE OWNER'S LONGER DELAY THAN STATED ABOVE, THE CONCRETE SHALL BE DISCARDED. IT NOT EXCEED ONE AND ONE HALF (1-1/2) HOURS. IF FOR ANY REASON THERE IS A MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM THE TIME THE TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED WHEN ALL THE REQUIREMENTS OF ASTM STANDARD C94 FOR MEASURING, MIXING, NUMBER OR OTHER POSITIVE IDENTIFICATION. CONCRETE SHALL COMPLY WITH TESTS FOR REVIEW PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX 2. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB MAT SLAB FOUNDATIONS 5,000 psi NWC - INTERIOR SLABS-ON-GRADE 3,000 psi NWC - SPREAD FOOTINGS AND ASSOCIATED PIERS 3,000 psi NWC - WORKABLE MIX: ACHIEVE A STRENGTH AT 28 DAYS AS LISTED BELOW WITH A PLASTIC AND 1. SHALL BE MIX DESIGNED BY A RECOGNIZED TESTING LABORATORY TO CONCRETE MIX DESIGN: ENGINEER. THOSE LOCATED ON THESE DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE NO PENETRATIONS SHALL BE MADE IN ANY STRUCTURAL MEMBERS OTHER THAN PENETRATIONS: THE ADDITIONAL CYLINDER(S) MAY BE DISCARDED. DIRECTION OF THE ENGINEER, IF REQUIRED. IF 28 DAY STRENGTH IS ACHIEVED, PROVIDE ONE ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER THE 2 AT 28 DAYS 1 AT 7 DAYS AGE AS FOLLOWS: THEREOF), PLACED PER DAY. REQUIRED CYLINDER(S) QUANTITIES AND TEST CONDUCTED FOR EACH CLASS, FOR EVERY 50 CUBIC YARDS (OR FRACTION CYLINDRICAL CONCRETE SPECIMENS." A SEPARATE TEST SHALL BE B) ASTM C39 - "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF CONCRETE." A) ASTM C143 - "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT CONCRETE: LABORATORY SHALL PERFORM THE FOLLOWING TESTS ON CAST-IN-PLACE 1. CONCRETE TESTING SHALL BE PAID FOR BY THE OWNER. TESTING CONCRETE TESTING: WELDED WIRE MESH WWM WELDED WIRE FABRIC WWF VERIFY IN FIELD VIF VERTICAL VERT UNLESS NOTED OTHERWISE UNO TYPICAL TYP TIE JOIST TJ THICKNESS THK TOP OF xx T.O.xx TOP OF WALL TOW TOP OF STEEL TOS TOP OF CONCRETE TOC TOP AND BOTTOM T&B TOP CHORD EXTENSION TCX SYMMETRICAL SYM SHORT WAY SW STEEL STL STANDARD STD SQUARE SQ SPECIFICATION SPEC SPECIAL JOIST SP SLAB ON GRADE SOG SLAB SL SIMILAR SIM SHEET SHT SECTION SECT SELF DRILLING SCREW SDS SCHEDULE SCHD SLIP CRITICAL SC REVISION REV REQUIRED REQD REINFORCEMENT REINF REFERENCE REF RADIUS R PRESSURE TREATED PT PARRALEL STRAND LUMBER PSL POUNDS PER SQUARE INCH PSI POUNDS PER SQUARE FOOT PSF POUNDS PER LINEAR FOOT PLF PLATE PL PRE-ENGINEERED P/E PRECAST PC POWDER ACTUATED FASTENER PAF OPENING OPNG OPPOSITE HAND OH OUTSIDE FACE OF ON CENTER OC NORMAL WEIGHT CONCRETE NWC NOT TO SCALE NTS NOMINAL NOM NUMBER No / # METAL MTL MASONRY PILASTER MP MISCELLANEOUS MISC MINIMUM MIN MIDDLE MID MANUFACTURER MFR MECHANICAL MECH MOMENT CONNECTION MC MAXIMUM MAX MASONRY MAS LIGHT WEIGHT CONCRETE LWC LONG WAY LW LAMINATED VENEER LUMBER LVL LAMINATED STRAND LUMBER LSL LOCATIONS LOC LOW LO LONG LEG VERTICAL LLV LONG LEG HORIZONTAL LLH POUNDS LBS KIPS PER LINEAR FOOT KLF KIPS PER SQUARE INCH KSI KNEE BRACE KB KIPS = 1000 LBS K JOINT JT INTERIOR INT INSIDE FACE IF HOLLOW STRUCTURAL SECTION HSS HIGH STRENGTH EPOXY HSE HORIZONTAL HORZ HIGH HI GRADE BEAM GB GALVANIZED GALV GAUGE GA FIELD VERIFY FV FOOTING FTG FOOTING STEP FS FACE OF WALL FOW FACE OF MASONRY FOM FOUNDATION FND FLOOR DRAIN FD FLOOR FLR FINISH FIN EXTERIOR EXT EXPANSION EXP EXISTING EXIST EACH WAY EW EQUIPMENT EQUIP EQUAL EQ EDGE OF STEEL EOS EDGE OF DECK EOD ENGINEER ENGR EMBEDDED / EMBEDMENT EMBED ELEVATION EL, ELEV EXPANSION JOINT EJ EACH FACE EF EACH EA DOWEL DWL DRAWINGS DWGS DOWN DN DECK DK DIMENSION DIM DIAGONAL DIAG DIAMETER DIA DETAIL DET,DTL DEGREE DEG DOUBLE DBL DEFORMED BAR ANCHOR DBA NAIL PENNY WEIGHT d COMPLETE PENETRATION CP CONTINUOUS CONT CONSTRUCTION CONST CONCRETE CONC COLUMN COL CONCRETE MASONRY UNIT CMU CLEAR CLR CONTROL JOINT CJ CENTERLINE CL CANTILEVER CANT BEARING BRG BEAM BM BUILDING BLDG BOTTOM OF STEEL BOS BOTTOM OF xx B.O.xx BOTTOM BOT BELOW FINISHED FLOOR BFF BOTTOM CHORD EXTENSION BCX ARCHITECT ARCH ALTERNATE ALT ABOVE FINISHED FLOOR AFF ADJACENT ADJ ANCHOR BOLTS AB DEFINITION ABBREV. STRUCTURAL ABBREVIATIONS: FLANGE WIDTH MINIMUM METAL THICKNESS (mils) TYPE OF MEMBER DEPTH OF MEMBER INDUSTRY-STANDARD NOMENCLATURE 600 S 162 - 43 6. LIGHT GAGE STRUCTURAL STEEL FRAMING AS SHOWN ON THESE PLANS CONFORMS TO THE INDUSTRY-STANDARD NOMENCLATURE. EXPLANATION OF THIS NOMENCLATURE IS SHOWN BELOW FOR REFERENCE: LOCATED. PROFESSIONAL ENGINEER, REGISTERED IN THE STATE WHERE THE PROJECT IS CONCEPT ONLY. FINAL DESIGN AND DETAILING SHALL BE DONE BY A QUALIFIED 9. ALL COLD-FORMED FRAMING SHOWN ON THE STRUCTURAL DRAWINGS IS MINIMUM PREPARATION. REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED, RESPONSIBLE FOR THEIR CALCULATIONS SIGNED AND SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER, C. STRUCTURAL DESIGN CALCULATIONS: COMPLETE STRUCTURAL DESIGN WHERE THE PROJECT IS LOCATED. AND SEALED BY A QUALIFIED PROFESSIONAL ENGINEER, REGISTERED IN THE STATE ADJOINING WORK. SHOP DRAWINGS MUST BE PREPARED UNDER THE SUPERVISION OF BRIDGING, SPLICES, ACCESSORIES, CONNECTION DETAILS, AND ATTACHMENT TO CHANNELS, OPENING FRAMING, SUPPLEMENTAL FRAMING, STRAPPING, BRACING, ANCHORAGE DETAILS, INCLUDING MECHANICAL FASTENERS. SHOW REINFORCING TYPES OF COLD-FORMED METAL FRAMING; FABRICATION; AND FASTENING AND B. SHOP DRAWINGS: SHOW LAYOUT, SPACINGS, SIZES, THICKNESSES, AND PRODUCT AND ACCESSORY INDICATED. A. PRODUCT DATA: FOR EACH TYPE OF COLD-FORMED METAL FRAMING 8. SUBMITTALS: STRUCTURAL MEMBERS” “NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL 7. DESIGN ALL MEMBERS ACCORDING TO AMERICAN IRON & STEEL INSTITUTE (AISI) LOAD DEFLECTION OF PRIMARY BUILDING STRUCTURE OF 3/4" UPWARD OR DOWNWARD OPENINGS, TO ALLOW FOR CONSTRUCTION TOLERANCES, AND TO ACCOMMODATE LIVE 6. DESIGN NON-LOAD BEARING FRAMING SYSTEM TO MAINTAIN CLEARANCES AT COATING CONFORMING TO ASTM A525, CLASS G60. 5. COLD-FORMED STEEL SHALL SATISFY ASTM A653 WITH HOT DIPPED GALVANIZED MEMBERS. 4. ASSUME NON-STRUCTURAL SHEATHING PROVIDES NO LATERAL BRACING TO FRAMING 1/360 BACKING OTHER MATERIALS 1/600 BACKING BRICK VENEER EXTERIOR WALL FRAMING: 1/360 (HORIZONTAL LOAD OF 5 psf.) INTERIOR WALL FRAMING: OF THE WALL: WITHOUT HORIZONTAL DEFLECTIONS GREATER THAN THE FOLLOWING FOR THE HEIGHT 3. DEFLECTION LIMITS: DESIGN FRAMING SYSTEMS TO WITHSTAND DESIGN LOADS WIND, & SEISMIC DESIGN LOADS LISTED ON THE STRUCTURAL DRAWINGS. 2. COLD-FORMED METAL FRAMING SHALL BE CAPABLE OF WITHSTANDING DEAD, LIVE, BEARING WALLS, FLOOR JOIST FRAMING, ROOF TRUSS AND RAFTER FRAMING. THE FOLLOWING: EXTERIOR AND INTERIOR LOAD-BEARING WALL, EXTERIOR NON-LOAD 1. ENGINEER, FABRICATE AND INSTALL COLD-FORMED STRUCTURAL STEEL FRAMING FO COLD FORMED LIGHT GAGE STRUCTURAL STEEL: SPECIAL INSPECTION AND TESTING: 1. SPECIAL INSPECTION AND MINIMUM TESTING SHALL BE PERFORMED IN ACCORDANCE WITH 2012 NCSBC, TABLES 1704.3 (STEEL), 1704.4 (CONCRETE), AND 1704.5.1 (MASONRY). 2. INSPECTION & TESTING SHALL BE PROVIDED BY AN INDEPENDENT TESTING AGENCY HIRED AT THE OWNER'S EXPENSE. AGENCY INSPECTION PERSONEL SHALL MEET THE INSPECTOR QUALIFICATIONS FOR EACH MATERIAL ITEM AS INDICATED IN THE SPECIFICATIONS. ALL RE-TESTING DUE TO FAILURE OF ORIGINAL TEST SHALL BE PAID FOR BY THE GENERAL CONTRACTOR. 3. ANY MATERIAL OR PLACEMENT DEVIATIONS FROM MINIMUMS SHOWN ON THE DRAWINGS OR IN SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. ENGINEERED REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. DRAWINGS SHALL BEAR THE SIGNATURE AND SEAL OF A PROFESSIONAL AS WELL AS ALL PERMANENT BRACING REQUIRED FOR TRUSS DESIGN. SHOP DRAWING SHALL BE INCLUDED, IDENTIFYING ALL TRUSS SYSTEM COMPONENTS, SUPPLIED AS PART OF THE ENGINEERED TRUSS SYSTEM. AN ERECTION OTHER CONNECTIONS AND ATTACHMENTS BETWEEN TRUSSES OR COMPONENTS TYPES UTILIZED WITHIN TRUSSES, AS WELL AS CONNECTORS UTILIZED IN ALL FABRICATION. SHOP DRAWINGS SHALL SHOW AND SPECIFY ALL CONNECTOR 5. SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO GALVANIZED COATING CONFORMING TO ASTM A525 (CLASS G-60). OTHER) STEEL SECTIONS, COMPLYING WITH ASTM C995, WITH HOT DIPPED 4. TRUSS MEMBERS SHALL BE MANUFACTURER'S STANDARD C-SHAPED (OR DEFLECTION OF L/360 LIVE LOAD AND L/240 TOTAL LOAD. 3. METAL ROOF TRUSSES SHALL BE DESIGNED FOR A MAXIMUM VERTICAL BOTTOM CHORD. RESISTING DEAD LOAD EQUAL TO 9 PSF ON THE TOP CHORD AND 0 PSF ON THE 2. WIND LOAD: WHEN CALCULATING NET UPLIFT REACTIONS, USE MAXIMUM LIVE LOAD = 0 psf DEAD LOAD = 5 psf BOTTOM CHORD: B) WIND LOAD = SEE DESIGN LOADS SNOW LOAD = 11 psf LIVE LOAD = 20 psf DEAD LOAD = 15 psf TOP CHORD: A) FOLLOWS: THE TRUSSES AND UNIFORM LOADS AS INDICATED ON THIS SHEET AND AS DESIGNED AND DETAILED BY THE MANUFACTURER TO SUSTAIN SELF WEIGHT OF 1. PRE-ENGINEERED LIGHT GAGE METAL ROOF TRUSS SYSTEMS SHALL BE PRE-ENGINEERED LIGHT GAGE METAL ROOF TRUSSES: STRUCTURAL STEEL: 1. STEEL SHALL CONFORM TO ASTM A992 (Fy=50 ksi) FOR ALL W-SHAPES, AND ASTM A36 (Fy=36 ksi) FOR ALL OTHER MISCELLANEOUS SHAPES AND PLATES. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B (Fy=46 ksi). STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B, TYPE "E" OR "S" (Fy=42 ksi). 2. STEEL SHALL CONFORM TO THE LATEST EDITION OF "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC (AISC). 3. ALL STRUCTURAL STEEL EXPOSED TO EXTERIOR SHALL BE HOT-DIPPED GALVANIZED. 4. ALL SHOP CONNECTIONS TO BE WELDED (UTLIZING E70XX ELECTRODES) AND FIELD CONNECTIONS TO BE BOLTED, UNLESS OTHERWISE NOTED. STEEL TO RECEIVE ONE SHOP COAT AND ONE FIELD TOUCH UP COAT OF APPROVED PAINT, EXCEPT WHERE GALVANIZED IS INDICATED ON THE DRAWINGS. 5. WELDS FOR ALL EXPOSED STRUCTURAL STEEL SHALL BE GROUND SMOOTH UNLESS NOTED OTHERWISE. 6. ALL BOLTED CONNECTIONS SHALL CONSIST OF 3/4" DIAMETER (MIN.) ASTM A325 HIGH STRENGTH BOLTS, UNLESS NOTED OTHERWISE. BEAM CONNECTIONS SHALL BE DESIGNED BY THE FABRICATOR TO SUPPORT AN END REACTION OF Wc/2L KIPS IN ACCORDANCE WITH PART 2 - "BEAM AND GIRDER DESIGN" OF THE MANUAL OF STEEL CONSTRUCTION (9th EDITION), BUT CONNECTIONS SHALL NOT HAVE LESS THAN 2 ROWS OF BOLTS. SEE ALSO DOUBLE ANGLE AND SHEAR TAB CONNECTION SCHEDULE(S) WHERE APPLICABLE. 7. CONTRACTOR TO FURNISH AND INSTALL 500 lbs. OF ADDITIONAL MISCELANEOUS STEEL TO BE USED AT ENGINEER'S DISCRETION. SHEAR STUD CONNECTORS: 1. SHEAR STUD CONNECTORS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING CODE", SECTION 7 - STUD WELDING. STUDS SHALL BE TYPE "B", HEADED STUDS, HAVING A MINIMUM TENSILE STRENGTH OF 60,000 psi, AND SHALL BE OF LENGTH AND DIAMETER SHOWN ON THE DRAWINGS. COMPOSITE STEEL FORM DECK: 1. COMPOSITE FORM DECK SHALL BE THE SIZE INDICATED ON STRUCTURAL DRAWINGS, GAGE G60 CORRUGATED STEEL COMPOSITE DECK AND SHALL CONFORM TO THE PROVISIONS OF THE STEEL DECK INSTITUTE (SDI) SPECIFICATIONS FOR COMPOSITE STEEL DECK. STEEL ROOF DECK: 1. STEEL ROOF DECK SHALL BE THE SIZE INDICATED ON STRUCTURAL DRAWINGS, PAINTED WIDE RIBBED STEEL ROOF DECK AND SHALL CONFORM TO THE PROVISIONS OF THE STEEL DECK INSTITUTE (SDI) SPECIFICATIONS FOR STEEL ROOF DECK. 2. STEEL ROOF DECKS ARE DESIGNED AS HORIZONTAL DIAPHRAGMS AND SHALL BE ATTACHED TO SUPPORTS IN SDI PATTERNS AS INDICATED ON THE DRAWINGS. MASONRY PRISM TESTING: 1. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL CONSTRUCT THREE (3) TEST PRISMS FOR TESTING. THEY SHALL BE CONSTRUCTED OF TWO (2) 8"x8"x16" PRISMS FOR TESTING, ONE (1) ON TOP OF THE OTHER, JOINED WITH TYPE "S" MORTAR, AND FILLED WITH 3,000 psi CONCRETE GROUT. PRISMS SHALL BE CURED FOR 28 DAYS. NO REINFORCING SHALL BE USED IN THE CONSTRUCTION OF THE PRISMS. 2. PRISMS SHALL BE MADE OF THE SAME MATERIALS, UNDER THE SAME CONDITIONS, AND INSOFAR AS POSSIBLE, WITH THE SAME BONDING ARRANGEMENTS AS FOR THE STRUCTURE. THE MOISTURE CONTENT OF THE UNITS AT THE TIME OF LAYING, CONSISTENCY OF MORTAR, AND WORKMANSHIP SHALL BE THE SAME AS WILL BE USED IN THE STRUCTURE. THE VALUE OF f'm SHALL BE THE AVERAGE OF ALL SPECIMENS TESTED BUT SHALL BE NOT MORE THAN 125 PERCENT OF THE MINIMUM VALUE DETERMINED BY THE TEST, WHICHEVER IS LESS. 3. TESTING SHALL INCLUDE TESTS IN ADVANCE OF BEGINNING OPERATIONS AS DESCRIBED ABOVE, AND AT LEAST ONE (1) FIELD TEST DURING CONSTRUCTION FOR EACH 5,000 SQUARE FEET OF WALL, BUT NOT LESS THAN ONE (1) FIELD TEST MINIMUM IF TOTAL SQUARE FEET OF WALL FOR ENTIRE PROJECT IS LESS THAN 5,000 SF. ONLY WALLS INDICATED ON STRUCTURAL PLANS NEED BE TESTED. 4. THE COMPRESSIVE STRENGTH, f'm, SHALL BE COMPUTED BY DIVIDING THE ULTIMATE LOAD BY THE NET AREA OF THE MASONRY USED IN THE CONSTRUCTION OF THE PRISMS. 5. TEST PRISMS SHALL BE STORED FOR SEVEN DAYS IN AIR, AT A TEMPERATURE OF 70 DEGREES, PLUS OR MINUS 5 DEGREES, IN A RELATIVE HUMIDITY EXCEEDING 90%, AND THEN IN AIR AT A TEMPERATURE OF 70 DEGREES, PLUS OR MINUM 5 DEGREES, UNTIL TESTED. THOSE CONSTRUCTED IN THE FIELD SHALL BE STORED UNDISTURBED FOR FROM 48 TO 96 HOURS UNDER WET MATERIAL TO SIMULATE 90% HUMIDITY, THEN TRANSPORTED TO LABORATORY FOR CONTINUED CURING AS DESCRIBED ABOVE. 6. NOT LESS THAN THREE (3) PRISM SPECIMENS SHALL BE MADE FOR EACH FIELD TEST TO CONFIRM THAT THE MATERIALS ARE AS ASSUMED IN THE DESIGN. THE STANDARD AGE OF TEST SPECIMENS SHALL BE 28-DAYS, BUT 7-DAY TESTS MAY BE USED, PROVIDED THE RELATION BETWEEN THE 7-DAY AND 28-DAY STRENGTHS OF THE MASONRY IS ESTABLISHED BY ADEQUATE TEST DATA FOR THE MATERIALS USED. MASONRY MATERIALS: 1. MASONRY UNITS SHALL MEET ASTM C90 TYPE I, GRADE N, FOR HOLLOW LOAD BEARING TYPE MASONRY WITH A UNIT STRENGTH OF 1,900 psi ON THE NET AREA (f'm = 1,500 psi). 2. MORTAR SHALL BE TYPE "M" (BELOW GRADE) OR "S" (ABOVE GRADE) AND SHALL MEET ASTM C270. GROUT SHALL BE 3,000 psi PEA-GRAVEL CONCRETE AND SHALL MEET ASTM C476. MORTAR MIX DESIGN SHALL BE TESTED PRIOR TO CONSTRUCTION USING MORTAR TEST CUBES, WITH 7-DAY STRENGTH OF LABORATORY MIX EXCEEDING THE 28-DAY SPECIFIED DESIGN STRENGTH. GROUT SHALL BE TESTED PRIOR TO CONSTRUCTED USING PRISMS AS DESCRIBED ABOVE. MASONRY AND REINFORCED MASONRY PLACEMENT: 1. ALL MASONRY SHALL BE LAID IN RUNNING BOND UNLESS NOTED OTHERWISE. MATERIALS TO BE LAID AND MATERIALS TO BE BUILT UPON SHALL BE FREE FROM SNOW AND ICE. 2. PROVIDE HOOKED DOWELS INTO FOOTINGS FOR ALL VERTICAL REINFORCING ABOVE AS SHOWN IN THE DRAWINGS. LAP SPLICES A MINIMUM OF 48 BAR DIAMETERS. AT THE OPTION OF THE CONTRACTOR, DOWELS MAY BE DRILLED AND EPOXIED INTO FOOTING IN LIEU OF HOOKS. EPOXY SHALL BE AS NOTED ON THIS SHEET UNDER 'CHEMICAL ANCHORS,' 6" MIN. EMBEDMENT FOR #5 OR SMALLER DOWELS, 8" MIN. EMBEDMENT FOR #6 DOWELS. 3. PROVIDE DUR-O-WALL (OR EQUAL PER SPECIFICATIONS) LADDER OR TRUSS HORIZONTAL JOINT REINFORCEMENT AT EACH SECOND COURSE IN RUNNING BOND, AND EACH COURSE IN STACKED BOND, UNLESS NOTED OTHERWISE. DISCONTINUE HORIZONTAL JOINT REINFORCEMENT AT CONTROL JOINTS. 4. PROVIDE BOND BEAMS REINFORCED WITH (2) #5 BARS EVERY 6'-0" OF VERTICAL WALL, AT TOPS OF ALL MASONRY WALLS, AND WHERE SHOWN ON DRAWINGS. AT BOND BEAM CORNERS AND TEE JOINTS, PROVIDE BENT BARS TO MATCH QUANTITY AND BAR SIZE IN THE BOND BEAM. LAPS IN BOND BEAMS SHALL BE 48 BAR DIAMETERS OR A MINIMUM OF 2'-0", WHICHEVER IS GREATER. 5. WHERE SHOWN ON THE DRAWINGS, CORES IN CONCRETE BLOCK UNITS SHALL BE FILLED WITH 3,000 psi CONCRETE GROUT FROM TOP OF FOOTING TO BOTTOM OF BEARING, OR TO THE TOP OF WALL, DEPENDING ON THE CONDITION. INSPECTION OF OPENING AT BOTTOM IS REQURIED. 6. WHERE REINFORCING STEEL IS CALLED FOR IN FILLED CORES, IT SHALL EXTEND FROM TOP OF FOOTING TO BOTTOM OF BEARING, OR TOP OF WALL, DEPENDING ON CONDITION. 7. WHERE REINFORCING STEEL IS INTERRUPTED BY AN OPENING IN THE WALL, THE QUANTITY OF BARS INTERRUPTED ARE TO BE MOVED TO EACH SIDE OF THE OPENING, HALF OF REINFORCING TO ONE SIDE AND REMAINING HALF TO THE OTHER SIDE. REINFORCING SHALL BE FROM TOP OF FOOTING TO TOP OF WALL. PROVIDE A MINIMUM OF (2) #5 VERTICAL REINFORCING BARS AT EACH JAMB. SEE PLAN NOTES AND/OR DETAILS FOR VERTICAL REINFORCING SPACING. 8. WHERE VERTICAL REINFORCING STEEL IS SPLICED IN MASONRY, PROVIDE A MINIMUM OF 48 BAR DIAMETERS, LAP SPLICE, UNLESS NOTED OTHERWISE. 9. THE MINIMUM DISTANCE BETWEEN PARALLEL BARS, EXCEPT IN COLUMNS, SHALL BE NOT LESS THAN THE DIAMETER OF THE BAR EXCEPT THAT LAPPED SPLICES MAY BE WIRED TOGETHER. THE CENTER TO CENTER SPACING OF BARS WITHIN A COLUMN SHALL BE NOT LESS THAN 2 AND ONE-HALF TIMES THE BAR DIAMETER. 10. ALL BARS SHALL BE COMPLETELY EMBEDDED IN MORTAR OR CONCRETE. REINFORCEMENT EMBEDDED IN HORIZONTAL MORTAR JOINTS SHALL HAVE NOT LESS THAN 5/8" MORTAR COVERAGE FROM THE EXPOSED FACE. ALL OTHER REINFORCING SHALL HAVE A MINIMUM COVERAGE OF ONE BAR DIAMETER OVER ALL BARS, BUT NOT LESS THAN 3/4", EXCEPT WHERE EXPOSED TO WEATHER OR SOIL IN WHICH CASE THE MINIMUM COVERAGE SHALL BE 2". 11. WHERE REINFORCING IS SHOWN TO BE LOCATED ALONG TWO FACES OF A CONCRETE BLOCK WALL, THE CONTRACTOR SHALL BREAK OUT THE SHELL OF THE LOWEST CONCRETE BLOCK TO GAIN ACCESS TO THE REINFORCING STEEL. THE REINFORCED STEEL SHALL THEN BE WIRED INTO ITS CORRECT POSITION, AND THE ACCESS HOLE COVERED. THE CONCRETE GROUT FILL SHALL BE PUDDLED OR VIBRATED TO ASSURE COMPLETE FILLING OF THE CORE. 12. REINFORCED MASONRY PIERS AND COLUMNS SHALL HAVE THE REINFORCING STEEL ACCURATELY LOCATED BY WIRING THE TOP AND BOTTOM OF ALL VERTICAL STEEL INTO ITS CORRECT POSITION. PROVIDE AN ACCESS HOLE AT THE BOTTOM OF ALL COLUMNS OR PIERS. 13. ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND CROSS WEBS FORMING SUCH CELLS TO BE FILLED SHALL BE FULLBEDDED IN MORTAR TO PREVENT LEAKAGE OF CONCRETE GROUT. ALL HEAD (OR END) JOINTS SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM THE FACE OF THE WALL OR UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE SHELLS. BOND SHALL BE PROVIDED BY LAPPING UNITS IN SUCCESSIVE VERTICAL COURSES OR BY EQUIVALENT MECHNICAL ANCHORAGE. A) VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED CONTINUOUS VERTICAL CELL MEASURING NOT LESS THAN 2"x3". B) CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF ALL CELLS TO BE FILLED AT EACH POUR OF CONCRETE WHERE SUCH CONCRETE POUR IS IN EXCESS OF 6' IN HEIGHT. ANY OVERHANGING MORTAR, OTHER OBSTRUCTION OR DEBRIS SHALL BE REMOVED AND/OR CLEANED AT TIME OF INSPECTION AND PRIOR TO CORE FILLING. INSPECT AND SEAL ALL OPENINGS BEFORE CONCRETING. C) VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND AT INTERVALS NOT EXCEEDING 192 DIAMETERS OF THE REINFORCEMENT. D) ALL CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLIDLY WITH CONCRETE. CONCRETE SHALL BE POURED IN LIFTS OF 8' MAXIMUM HEIGHT. ALL CONCRETE SHALL BE CONSOLIDATED AT THE TIME OF POURING BY PUDDLING FOR LIFTS OF 4' OR LESS, OR BY VIBRATING FOR LIFTS GREATER THAN 4'. CONCRETE SHOULD LATER BE CONSOLIDATED AGAIN BY PUDDLING, BEFORE PLASTICITY IS LOST. E) WHEN TOTAL CONCRETE POUR EXCEEDS 8' IN HEIGHT, THE CONCRETE SHALL BE PLACED IN 4' MAXIMUM LIFTS. MINIMUM CELL DIMENSION SHALL BE 3". F) WHEN CONCRETING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF CONCRETE 1 1/2" BELOW THE TOP OF THE UPPERMOST UNIT. 14. PROVIDE A MINIMUM OF 8" BEARING FOR ALL MASONRY LINTELS. 15. WHERE LINTEL BLOCKS ARE USED IN LIEU OF HOLLOW CONCRETE BLOCKS, THE REINFORCING STEEL SHALL BE ANCHORED TO THE LOWER STEEL OR DOWELS AND THE LINTEL BLOCKS LAID AROUND THE STEEL. THE CONCRETE FILL SHALL BE INSTALLED IN LIFTS NOT TO EXCEED 2' IN HEIGHT. THE REINFORCING STEEL SHALL BE MAINTAINED IN THE SAME POSITION AS THE DOWELS. STOP THE POUR OF THE CONCRETE 1 1/2" BELOW THE TOP OF THE UPPERMOST UNIT. 16. SPECIFICATION REQUIREMENTS FOR COLD WEATHER AND HOT WEATHER MASONRY CONSTRUCTION SHALL BE MAINTAINED. ACI 530-13 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. AISI S100-12 NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS FACTOR AND EXPOSURE LISTED ABOVE. THE NORTH CAROLINA STATE BUILDING CODE FOR THE BASIC DESIGN WIND VELOCITY, IMPORTANCE ARE TO BE DESIGNED BY THE MANUFACTURER'S ENGINEER FOR WIND LOADS DETERMINED PER ALL BUILDING COMPONENTS AND CLADDING ENGINEERED BY THE COMPONENT MANUFACTURER COMPONENT & CLADDING: 155k Vy = 142.5k Vx = WIND BASE SHEARS, III RISK CATEGORY D EXPOSURE CATEGORY 145 mph BASIC WIND SPEED (3 SEC GUST) WIND: 10 psf SUPERIMPOSED DEAD LOAD FLOOR: SNOW LOAD IMPORTANCE FACTOR 0.9 Ce = SNOW EXPOSURE FACTOR 11 psf Pf = DESIGN ROOF SNOW LOAD Pg= GROUND SNOW LOAD 20 psf ROOF LIVE LOAD 10 psf SUPERIMPOSED DEAD LOAD ROOF: SUPERIMPOSED LOADINGS: THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED WITH THE FOLLOWING DESIGN LOADS: D SITE CLASSIFICATION B DESIGN CATEGORY E-L-F ANALYSIS PROCEDURE USED: 3-1/4 R = RESPONSE MODIFICATION FACTOR .0581 Cs = SEISMIC RESPONSE COEFFICIENT 54.7k Vy = 54.7k Vx = DESIGN BASE SHEARS SEISMIC RESISTING SYSTEM: 0.096g Sd1 = 0.126g Sds = SPECTRAL RESPONSE COEFF., 0.06g S1 = 0.91g Ss = MAPPED SPECTRAL RESPONSE ACCELERATIONS, RISK CATEGORY 1.25 Ie = IMPORTANCE FACTOR, SEISMIC: 1.0 Ct = THERMAL FACTOR 1.10 Is = 100 psf FLOOR LIVE LOAD (PUBLIC ROOMS & CORRIDORS) 100 psf STAIRS III STEEL ORDINARY CONCENTRICALLY BRACED FRAMES & INTERMEDIATE REINFORCED MASONRY SHEAR WALLS 10 psf ROOF LIVE LOAD (PUBLIC) 100 psf ELEVATED SLABS 4,000 psi NWC - FOUNDATION WALLS 5,000 psi NWC - DESIGNED BY: DRAWN BY: APPROVED BY: PROJECT #: DATE: No. Revision Date Sheet Ownership of Instruments of Service: All reports, plans, specifications, computer files, field data, notes and instruments prepared by the design professional as instruments of service shall remain the property of the design professional. All common law, statutory and other reserved rights including the copyright thereto. Sheet Title Project Name CLUBHOUSE MOREHEAD CITY, NORTH CAROLINA MOREHEAD CITY COUNTRY CLUB 20-254 01/29/2021 GENERAL NOTES HMH HMH HMH S0.1 Digitally signed by Heath M. Hendrick Date: 2021.01.30 06:13:10 -05'00'
Transcript
Page 1: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

30).

SDI DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS (PUBLICATION No.

AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, ALLOWABLE STRESS DESIGN.

ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY.

2018 NORTH CAROLINA STATE BUILDING CODE.

DESIGN CODES:

AND GENERAL NOTES SUCH AS 'DIMENSIONS CORRECTED' ARE NOT ACCEPTABLE.

AND DESCRIPTIONS OF ALL CHANGES MADE FROM PREVIOUS SUBMITTAL. LIST SHALL BE SPECIFIC

6. ALL SHOP DRAWING RESUBMITTALS SHALL INCLUDE A WRITTEN DETAILED LIST OF LOCATIONS

APPROVAL.

ALL PERSONNEL DEEMED NECESSARY BY CONTRACTOR PRIOR TO SUBMITTAL TO ENGINEER FOR

5. ALL STRUCTURAL SHOP DRAWINGS TO BE REVIEWED BY JOB SUPERINTENDENT IN ADDITION TO

EXPENSE OF THE CONTRACTOR.

ADDITIONAL OBSERVATIONS DUE TO THE DEFICIENCIES IN WORK OBSERVED WILL BE AT THE

4. ADDITIONAL OBSERVATIONS AS A RESULT OF REJECTION OF WORK COMPLETED AND/OR

TEMPORARY BRACING (AND ACCOMPANYING FOOTINGS), GUYS OR TIEDOWNS.

DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,

PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS

COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION

3. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS

BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK.

DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER

2. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD AND WITH ALL OTHER

DRAWINGS.

DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL

ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT THESE

1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND

GENERAL NOTES:

STRUCTURAL NOTES

PERMANENTLY EXPOSED TO EXTERIOR.

SHALL BE A36 THREADED ROD. PROVIDE HOT DIP GALVANIZE FINISH ON ALL ANCHOR BOLTS

ANCHOR BOLTS:

MANUFACTURER'S REPRESENTATIVE.

ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. INSTALLERS SHALL BE TRAINED BY THE

SIKA "SIKADUR INJECTION SEL", "HILTI-HIGH STRENGTH EPOXY", OR APPROVED EQUAL, INSTALLED IN

SHALL BE A POLYMER INJECTION SYSTEM SUCH AS RAMSET "EPCON", MOLLY "PARAMOUNT HVC",

CHEMICAL ANCHORS:

LOCATIONS AND SIZES SHALL BE APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.

OR 6" CLEAR BETWEEN SLEEVES, WHICHEVER IS GREATER. PRIOR TO CONSTRUCTION SLEEVE

MINIMUM SLEEVE SPACING SHALL BE TWO DIAMETERS CENTER TO CENTER TO THE LARGER SLEEVE

PLUMBING SLEEVES:

ON GRANULAR ENGINEERED FILL MATERIAL.

REPORT FOR ALL REQUIREMENTS RELATED TO THE CONSTRUCTION OF THE SLAB AND FOOTINGS

3. DESIGNS BASED UPON AN ALLOWABLE BEARING CAPACITY OF 2,000 psf. SEE GEOTECHNICAL

CODES SECTION OF THESE STRUCTURAL NOTES.

REPORT FOR THE LOADS PRESCRIBED BY THE BUILDING CODE REFERENCED IN THE DESIGN

DESIGNS WERE BASED UPON STAYING WITHIN THE LIMITS GIVEN WITHIN THE GEOTECHNICAL

BUILDING TYPE IS THE RESPONSIBILITY OF THE GEOTECHNICAL ENGINEER. ALL STRUCTURAL

CONSTRUCTION DOCUMENTS. DETERMINING THE AMOUNT OF SETTLEMENT ACCEPTABLE FOR THE

SPECIFIC BUILDING TYPE, CONSTRUCTION TYPE, AND LIKELY LOADS SHOWN ON THE

2. GEOTECHNICAL RECOMMENDATIONS WERE PREPARED WITH SPECIFIC KNOWLEDGE OF THE

JULY 28, 2020DATE:-

ECS PROJECT No. 22:29313

MOREHEAD CITY, CARTERET COUNTY, NORTH CAROLINA

MOREHEAD CITY COUNTRY CLUB

GEOTECHNICAL ENGINEERING REPORTTITLE:-

PREPARED BY: ECS SOUTHEAST, LLP-

FOLLOWING:

INSTALLATION PROCEDURES. SITE PREPARATION AND FOUNDATION SHALL COMPLY WITH THE

1. SEE THE FOLLOWING REPORT FOR COMPLETE GEOTECHNICAL RECOMMENDATIONS AND

FOUNDATIONS:

REQUIREMENTS SET FORTH IN ACI STANDARDS 301 AND 347.

REMOVAL OF ALL FORMWORK, SHORES AND RESHORES SHALL MEET THE

LEAST TWO-THIRDS OF THE 28 DAY DESIGN STRENGTH. DESIGN, ERECTION AND

NO STRUCTURAL CONCRETE SHALL BE STRIPPED UNTIL IT HAS REACHED AT

FORMWORK AND SHORING:

DISCRETION.

ADDITIONAL #4 & #5 REINFORCING STEEL TO BE USED AT ENGINEER'S

12. CONTRACTOR TO FURNISH AND INSTALL 500 LINEAR FT. EACH OF

(CURRENT EDITIONS), RESPECTIVELY, SHALL BE MAINTAINED.

11. COLD WEATHER AND HOT WEATHER PROVISIONS OF ACI 306 AND 305

ENGINEER FOR ALL OPENINGS GREATER THAN 12"x12" FOR DESIGN.

EXTEND REINFORCING 2'-0" BEYOND OPENING IN BOTH DIRECTIONS. CONTACT

AROUND ALL OPENINGS GREATER THAN 12"x12" IN CAST-IN-PLACE CONCRETE.

10. PROVIDE TWO (2) #5'S, ONE AT EACH FACE, UNLESS NOTED OTHERWISE,

1 1/2"BEAMS AND COLUMNS

1 1/2"#14 AND #18

3/4"#11 BARS OR SMALLER

AND WALLS

OR IN CONTACT WITH THE GROUND, SLABS

NOT EXPOSED TO EARTH OR WEATHER

1 1/2"#5 BARS OR SMALLER

2"#6 THROUGH #18 BARS

EXPOSED TO EARTH OR WEATHER

EXPOSED TO EARTH

3"CAST AGAINST AND PERMANENTLY

MINIMUM COVERDESCRIPTION

9. REINFORCING STEEL SHALL RECEIVE CONCRETE COVER AS FOLLOWS:

THEM.THEM. CLIP ANGLES SHALL BE FURNISHED BY THE CONTRACTOR REQUIRING

THEM AND INSTALLED BY THE CONTRACTOR CASTING THE CONCRETE AROUND

CONCRETE INSERTS SHALL BE FURNISHED BY THE CONTRACTOR REQUIRING

OR CONCRETE INSERTS FOR FASTENING AND SECURING OTHER COMPONENTS.

8. WHERE SHOWN ON THE DRAWINGS, PROVIDE WELD PLATES, WELDMENTS,

REINFORCING.

THE FOOTINGS WITH SAME SIZE AND QUANTITY DOWEL AS THE VERTICAL

AND PIERS, OR VERTICAL REINFORCING IN WALLS, SHALL BE DOWELED INTO

4, UNLESS OTHERWISE NOTED. ALL VERTICAL REINFORCING STEEL IN COLUMNS

7. PROVIDE FOUNDATION DOWELS AS SHOWN. MINIMUM SIZE DOWELS TO BE #

CORNER BARS, UNLESS NOTED OTHERWISE.

WALL, BEAM OR FOOTING. PROVIDE MINIMUM OF 40 BAR DIAMETER LAP FOR ALL

6. PROVIDE CORNER BARS OF SAME BAR DIAMETER AS SPECIFIED FOR THE

ON DRAWINGS (CLASS B SPLICE).

DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER, UNLESS NOTE OTHERWISE

5. LAP ALL REINFORCING SPLICES IN CONCRETE A MINIMUM OF 48 BAR

ACCORDANCE WITH THE LATEST ACI MANUALS.

4. ALL REINFORCING STEEL BARS TO BE DETAILED AND PLACED IN

LAPS SHALL BE ONE SPACE PLUS 2".

PLACING DETAILS OF ACI STANDARDS AND THE SPECIFICATIONS. MINIMUM

FROM OIL, SCALE AND RUST. PLACE WWF IN ACCORDANCE WITH THE TYPICAL

3. WELDED WIRE FABRIC TO CONFORM TO ASTM A185 AND SHALL BE FREE

EXCEPT WHERE NOTED OTHERWISE. REINFORCING SHALL NOT BE WELDED.

2. ALL REINFORCING STEEL TO BE ASTM A615, GRADE 60 (#4 AND LARGER),

STRAIGHTEDGE AND THE FLOOR SHALL NOT EXCEED 1/4".

SLAB CONCRETE PLACEMENT. THE GAP AT ANY POINT BETWEEN THE

ALLOWING IT TO REST UPON TWO HIGH SPOTS WITHIN 28 DAYS AFTER

(UNLEVELED) 10 FT. STRAIGHTEDGE ANYWHERE ON THE SLAB AND

FLOOR FINISH TOLERANCES AS MEASURED BY PLACING A FREESTANDING

ACI 117 ITEM 4.5.7

3/8" ENVELOPE EITHER SIDE OF THE THEORETICAL DESIGN SURFACE.

ELEVATIONS OF SLABS-ON-GRADE TOP OF SLAB ELEVATION SHALL BE WITHIN A

ACI 117 ITEM 4.3.1.1

EXCEPT AS MODIFIED BELOW:

1. ALL CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 301 AND ACI 117

CONCRETE AND REINFORCING PLACEMENT:

SLABS SHALL NOT EXCEED 3%.

INCLUDE AN AIR-ENTRAINING ADMIXTURE; THE MAXIMUM AIR CONTENT IN THESE

8. CONCRETE FOR TROWEL-FINISHED INTERIOR CONCRETE FLOORS SHALL NOT

ENGINEER'S WRITTEN PERMISSION FOR THEIR USE.

7. NO SALTS OF ANY KIND MAY BE USED IN CONCRETE BEFORE OBTAINING THE

PERMISSION OF THE ENGINEER IS GIVEN.

PLASTICIZERS AND SUPER-PLASTICIZERS MAY BE USED ONLY WHEN WRITTEN

6. WATER REDUCING AGENTS MAY BE USED IN THE CONCRETE MIX.

TO 5% TO 7%.

5. ALL CONCRETE EXPOSED TO WEATHER OR EARTH SHALL BE AIR ENTRAINED

THAN SPECIFIED.

TO RECEIVE SPECIAL CURING IF THE COMPRESSIVE STRENGTHS ARE LESS

SHALL DETERMINE IF THE CONCRETE IS ACCEPTABLE, OR TO BE REMOVED, OR

SPECIFICATIONS ARE MINIMUM COMPRESSIVE STRENGTHS. THE ENGINEER

4. THE CONCRETE STRENGTHS SHOWN IN THE SECTION ABOVE AND IN THE

BY THE GEOTECHNICAL ENGINEER OR GEOTECHNICAL REPORT.

3. CONCRETE SHALL UTILIZE TYPE I/II CEMENT UNLESS OTHERWISE DIRECTED

WITH THE APPROVAL OF THE ENGINEER.

CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY

AREAS IN THE CURING MEMBRANE SHALL BE RECOATED DAILY. CALCIUM

THE WATER HAS LEFT THE UNFINISHED CONCRETE. ALL SCUFFED OR BROKEN

SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS

STANDARD C309 TYPE 1 AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND

ABOVE. ALL SLABS SHALL BE CURED USING CURING COMPOUND MEETING ASTM

REPRESENTATIVE AND THE CONTRACTOR OF ANY NONCOMPLIANCE WITH THE

SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE OWNER'S

LONGER DELAY THAN STATED ABOVE, THE CONCRETE SHALL BE DISCARDED. IT

NOT EXCEED ONE AND ONE HALF (1-1/2) HOURS. IF FOR ANY REASON THERE IS A

MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL

CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM THE TIME THE

TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED WHEN

ALL THE REQUIREMENTS OF ASTM STANDARD C94 FOR MEASURING, MIXING,

NUMBER OR OTHER POSITIVE IDENTIFICATION. CONCRETE SHALL COMPLY WITH

TESTS FOR REVIEW PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX

2. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB

MAT SLAB FOUNDATIONS5,000 psi NWC -

INTERIOR SLABS-ON-GRADE3,000 psi NWC -

SPREAD FOOTINGS AND ASSOCIATED PIERS3,000 psi NWC -

WORKABLE MIX:

ACHIEVE A STRENGTH AT 28 DAYS AS LISTED BELOW WITH A PLASTIC AND

1. SHALL BE MIX DESIGNED BY A RECOGNIZED TESTING LABORATORY TO

CONCRETE MIX DESIGN:

ENGINEER.

THOSE LOCATED ON THESE DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE

NO PENETRATIONS SHALL BE MADE IN ANY STRUCTURAL MEMBERS OTHER THAN

PENETRATIONS:

THE ADDITIONAL CYLINDER(S) MAY BE DISCARDED.

DIRECTION OF THE ENGINEER, IF REQUIRED. IF 28 DAY STRENGTH IS ACHIEVED,

PROVIDE ONE ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER THE

2 AT 28 DAYS

1 AT 7 DAYS

AGE AS FOLLOWS:

THEREOF), PLACED PER DAY. REQUIRED CYLINDER(S) QUANTITIES AND TEST

CONDUCTED FOR EACH CLASS, FOR EVERY 50 CUBIC YARDS (OR FRACTION

CYLINDRICAL CONCRETE SPECIMENS." A SEPARATE TEST SHALL BE

B) ASTM C39 - "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF

CONCRETE."

A) ASTM C143 - "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT

CONCRETE:

LABORATORY SHALL PERFORM THE FOLLOWING TESTS ON CAST-IN-PLACE

1. CONCRETE TESTING SHALL BE PAID FOR BY THE OWNER. TESTING

CONCRETE TESTING:

WELDED WIRE MESHWWM

WELDED WIRE FABRICWWF

VERIFY IN FIELDVIF

VERTICALVERT

UNLESS NOTED OTHERWISEUNO

TYPICALTYP

TIE JOISTTJ

THICKNESSTHK

TOP OF xxT.O.xx

TOP OF WALLTOW

TOP OF STEELTOS

TOP OF CONCRETETOC

TOP AND BOTTOMT&B

TOP CHORD EXTENSIONTCX

SYMMETRICALSYM

SHORT WAYSW

STEELSTL

STANDARDSTD

SQUARESQ

SPECIFICATIONSPEC

SPECIAL JOISTSP

SLAB ON GRADESOG

SLABSL

SIMILARSIM

SHEETSHT

SECTIONSECT

SELF DRILLING SCREWSDS

SCHEDULESCHD

SLIP CRITICALSC

REVISIONREV

REQUIREDREQD

REINFORCEMENTREINF

REFERENCEREF

RADIUSR

PRESSURE TREATEDPT

PARRALEL STRAND LUMBERPSL

POUNDS PER SQUARE INCHPSI

POUNDS PER SQUARE FOOTPSF

POUNDS PER LINEAR FOOTPLF

PLATEPL

PRE-ENGINEEREDP/E

PRECASTPC

POWDER ACTUATED FASTENERPAF

OPENINGOPNG

OPPOSITE HANDOH

OUTSIDE FACEOF

ON CENTEROC

NORMAL WEIGHT CONCRETENWC

NOT TO SCALENTS

NOMINALNOM

NUMBERNo / #

METALMTL

MASONRY PILASTERMP

MISCELLANEOUSMISC

MINIMUMMIN

MIDDLEMID

MANUFACTURERMFR

MECHANICALMECH

MOMENT CONNECTIONMC

MAXIMUMMAX

MASONRYMAS

LIGHT WEIGHT CONCRETELWC

LONG WAYLW

LAMINATED VENEER LUMBERLVL

LAMINATED STRAND LUMBERLSL

LOCATIONSLOC

LOWLO

LONG LEG VERTICALLLV

LONG LEG HORIZONTALLLH

POUNDSLBS

KIPS PER LINEAR FOOTKLF

KIPS PER SQUARE INCHKSI

KNEE BRACEKB

KIPS = 1000 LBSK

JOINTJT

INTERIORINT

INSIDE FACEIF

HOLLOW STRUCTURAL SECTIONHSS

HIGH STRENGTH EPOXYHSE

HORIZONTALHORZ

HIGHHI

GRADE BEAMGB

GALVANIZEDGALV

GAUGEGA

FIELD VERIFYFV

FOOTINGFTG

FOOTING STEPFS

FACE OF WALLFOW

FACE OF MASONRYFOM

FOUNDATIONFND

FLOOR DRAINFD

FLOORFLR

FINISHFIN

EXTERIOREXT

EXPANSIONEXP

EXISTINGEXIST

EACH WAYEW

EQUIPMENTEQUIP

EQUALEQ

EDGE OF STEELEOS

EDGE OF DECKEOD

ENGINEERENGR

EMBEDDED / EMBEDMENTEMBED

ELEVATIONEL, ELEV

EXPANSION JOINTEJ

EACH FACEEF

EACHEA

DOWELDWL

DRAWINGSDWGS

DOWNDN

DECKDK

DIMENSIONDIM

DIAGONALDIAG

DIAMETERDIA

DETAILDET,DTL

DEGREEDEG

DOUBLEDBL

DEFORMED BAR ANCHORDBA

NAIL PENNY WEIGHTd

COMPLETE PENETRATIONCP

CONTINUOUSCONT

CONSTRUCTIONCONST

CONCRETECONC

COLUMNCOL

CONCRETE MASONRY UNITCMU

CLEARCLR

CONTROL JOINTCJ

CENTERLINECL

CANTILEVERCANT

BEARINGBRG

BEAMBM

BUILDINGBLDG

BOTTOM OF STEELBOS

BOTTOM OF xxB.O.xx

BOTTOMBOT

BELOW FINISHED FLOORBFF

BOTTOM CHORD EXTENSIONBCX

ARCHITECTARCH

ALTERNATEALT

ABOVE FINISHED FLOORAFF

ADJACENTADJ

ANCHOR BOLTSAB

DEFINITIONABBREV.

STRUCTURAL ABBREVIATIONS:

FLANGE WIDTH

MINIMUM METAL THICKNESS (mils)

TYPE OF MEMBER

DEPTH OF MEMBER

INDUSTRY-STANDARD NOMENCLATURE

600 S 162 - 43

6. LIGHT GAGE STRUCTURAL STEEL FRAMING AS SHOWN ON THESE PLANS

CONFORMS TO THE INDUSTRY-STANDARD NOMENCLATURE. EXPLANATION OF

THIS NOMENCLATURE IS SHOWN BELOW FOR REFERENCE:

LOCATED.

PROFESSIONAL ENGINEER, REGISTERED IN THE STATE WHERE THE PROJECT IS

CONCEPT ONLY. FINAL DESIGN AND DETAILING SHALL BE DONE BY A QUALIFIED

9. ALL COLD-FORMED FRAMING SHOWN ON THE STRUCTURAL DRAWINGS IS MINIMUM

PREPARATION.

REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED, RESPONSIBLE FOR THEIR

CALCULATIONS SIGNED AND SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER,

C. STRUCTURAL DESIGN CALCULATIONS: COMPLETE STRUCTURAL DESIGN

WHERE THE PROJECT IS LOCATED.

AND SEALED BY A QUALIFIED PROFESSIONAL ENGINEER, REGISTERED IN THE STATE

ADJOINING WORK. SHOP DRAWINGS MUST BE PREPARED UNDER THE SUPERVISION OF

BRIDGING, SPLICES, ACCESSORIES, CONNECTION DETAILS, AND ATTACHMENT TO

CHANNELS, OPENING FRAMING, SUPPLEMENTAL FRAMING, STRAPPING, BRACING,

ANCHORAGE DETAILS, INCLUDING MECHANICAL FASTENERS. SHOW REINFORCING

TYPES OF COLD-FORMED METAL FRAMING; FABRICATION; AND FASTENING AND

B. SHOP DRAWINGS: SHOW LAYOUT, SPACINGS, SIZES, THICKNESSES, AND

PRODUCT AND ACCESSORY INDICATED.

A. PRODUCT DATA: FOR EACH TYPE OF COLD-FORMED METAL FRAMING

8. SUBMITTALS:

STRUCTURAL MEMBERS”

“NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL

7. DESIGN ALL MEMBERS ACCORDING TO AMERICAN IRON & STEEL INSTITUTE (AISI)

LOAD DEFLECTION OF PRIMARY BUILDING STRUCTURE OF 3/4" UPWARD OR DOWNWARD

OPENINGS, TO ALLOW FOR CONSTRUCTION TOLERANCES, AND TO ACCOMMODATE LIVE

6. DESIGN NON-LOAD BEARING FRAMING SYSTEM TO MAINTAIN CLEARANCES AT

COATING CONFORMING TO ASTM A525, CLASS G60.

5. COLD-FORMED STEEL SHALL SATISFY ASTM A653 WITH HOT DIPPED GALVANIZED

MEMBERS.

4. ASSUME NON-STRUCTURAL SHEATHING PROVIDES NO LATERAL BRACING TO FRAMING

1/360 BACKING OTHER MATERIALS

1/600 BACKING BRICK VENEEREXTERIOR WALL FRAMING:

1/360 (HORIZONTAL LOAD OF 5 psf.)INTERIOR WALL FRAMING:

OF THE WALL:

WITHOUT HORIZONTAL DEFLECTIONS GREATER THAN THE FOLLOWING FOR THE HEIGHT

3. DEFLECTION LIMITS: DESIGN FRAMING SYSTEMS TO WITHSTAND DESIGN LOADS

WIND, & SEISMIC DESIGN LOADS LISTED ON THE STRUCTURAL DRAWINGS.

2. COLD-FORMED METAL FRAMING SHALL BE CAPABLE OF WITHSTANDING DEAD, LIVE,

BEARING WALLS, FLOOR JOIST FRAMING, ROOF TRUSS AND RAFTER FRAMING.

THE FOLLOWING: EXTERIOR AND INTERIOR LOAD-BEARING WALL, EXTERIOR NON-LOAD

1. ENGINEER, FABRICATE AND INSTALL COLD-FORMED STRUCTURAL STEEL FRAMING FO

COLD FORMED LIGHT GAGE STRUCTURAL STEEL:

SPECIAL INSPECTION AND TESTING:

1. SPECIAL INSPECTION AND MINIMUM TESTING SHALL BE PERFORMED IN

ACCORDANCE WITH 2012 NCSBC, TABLES 1704.3 (STEEL), 1704.4 (CONCRETE), AND

1704.5.1 (MASONRY).

2. INSPECTION & TESTING SHALL BE PROVIDED BY AN INDEPENDENT TESTING

AGENCY HIRED AT THE OWNER'S EXPENSE. AGENCY INSPECTION PERSONEL SHALL

MEET THE INSPECTOR QUALIFICATIONS FOR EACH MATERIAL ITEM AS INDICATED IN

THE SPECIFICATIONS. ALL RE-TESTING DUE TO FAILURE OF ORIGINAL TEST SHALL

BE PAID FOR BY THE GENERAL CONTRACTOR.

3. ANY MATERIAL OR PLACEMENT DEVIATIONS FROM MINIMUMS SHOWN ON THE

DRAWINGS OR IN SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE

ENGINEER.

ENGINEERED REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED.

DRAWINGS SHALL BEAR THE SIGNATURE AND SEAL OF A PROFESSIONAL

AS WELL AS ALL PERMANENT BRACING REQUIRED FOR TRUSS DESIGN. SHOP

DRAWING SHALL BE INCLUDED, IDENTIFYING ALL TRUSS SYSTEM COMPONENTS,

SUPPLIED AS PART OF THE ENGINEERED TRUSS SYSTEM. AN ERECTION

OTHER CONNECTIONS AND ATTACHMENTS BETWEEN TRUSSES OR COMPONENTS

TYPES UTILIZED WITHIN TRUSSES, AS WELL AS CONNECTORS UTILIZED IN ALL

FABRICATION. SHOP DRAWINGS SHALL SHOW AND SPECIFY ALL CONNECTOR

5. SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO

GALVANIZED COATING CONFORMING TO ASTM A525 (CLASS G-60).

OTHER) STEEL SECTIONS, COMPLYING WITH ASTM C995, WITH HOT DIPPED

4. TRUSS MEMBERS SHALL BE MANUFACTURER'S STANDARD C-SHAPED (OR

DEFLECTION OF L/360 LIVE LOAD AND L/240 TOTAL LOAD.

3. METAL ROOF TRUSSES SHALL BE DESIGNED FOR A MAXIMUM VERTICAL

BOTTOM CHORD.

RESISTING DEAD LOAD EQUAL TO 9 PSF ON THE TOP CHORD AND 0 PSF ON THE

2. WIND LOAD: WHEN CALCULATING NET UPLIFT REACTIONS, USE MAXIMUM

LIVE LOAD = 0 psf

DEAD LOAD = 5 psfBOTTOM CHORD:B)

WIND LOAD = SEE DESIGN LOADS

SNOW LOAD = 11 psf

LIVE LOAD = 20 psf

DEAD LOAD = 15 psfTOP CHORD:A)

FOLLOWS:

THE TRUSSES AND UNIFORM LOADS AS INDICATED ON THIS SHEET AND AS

DESIGNED AND DETAILED BY THE MANUFACTURER TO SUSTAIN SELF WEIGHT OF

1. PRE-ENGINEERED LIGHT GAGE METAL ROOF TRUSS SYSTEMS SHALL BE

PRE-ENGINEERED LIGHT GAGE METAL ROOF TRUSSES:

STRUCTURAL STEEL:

1. STEEL SHALL CONFORM TO ASTM A992 (Fy=50 ksi) FOR ALL W-SHAPES, AND

ASTM A36 (Fy=36 ksi) FOR ALL OTHER MISCELLANEOUS SHAPES AND PLATES.

STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B (Fy=46 ksi).

STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B, TYPE "E" OR "S"

(Fy=42 ksi).

2. STEEL SHALL CONFORM TO THE LATEST EDITION OF "SPECIFICATION FOR

THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR

BUILDINGS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC (AISC).

3. ALL STRUCTURAL STEEL EXPOSED TO EXTERIOR SHALL BE HOT-DIPPED

GALVANIZED.

4. ALL SHOP CONNECTIONS TO BE WELDED (UTLIZING E70XX ELECTRODES) AND

FIELD CONNECTIONS TO BE BOLTED, UNLESS OTHERWISE NOTED. STEEL TO

RECEIVE ONE SHOP COAT AND ONE FIELD TOUCH UP COAT OF APPROVED

PAINT, EXCEPT WHERE GALVANIZED IS INDICATED ON THE DRAWINGS.

5. WELDS FOR ALL EXPOSED STRUCTURAL STEEL SHALL BE GROUND SMOOTH

UNLESS NOTED OTHERWISE.

6. ALL BOLTED CONNECTIONS SHALL CONSIST OF 3/4" DIAMETER (MIN.) ASTM

A325 HIGH STRENGTH BOLTS, UNLESS NOTED OTHERWISE. BEAM

CONNECTIONS SHALL BE DESIGNED BY THE FABRICATOR TO SUPPORT AN END

REACTION OF Wc/2L KIPS IN ACCORDANCE WITH PART 2 - "BEAM AND GIRDER

DESIGN" OF THE MANUAL OF STEEL CONSTRUCTION (9th EDITION), BUT

CONNECTIONS SHALL NOT HAVE LESS THAN 2 ROWS OF BOLTS. SEE ALSO

DOUBLE ANGLE AND SHEAR TAB CONNECTION SCHEDULE(S) WHERE

APPLICABLE.

7. CONTRACTOR TO FURNISH AND INSTALL 500 lbs. OF ADDITIONAL

MISCELANEOUS STEEL TO BE USED AT ENGINEER'S DISCRETION.

SHEAR STUD CONNECTORS:

1. SHEAR STUD CONNECTORS SHALL BE FABRICATED AND INSTALLED IN

ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING CODE", SECTION 7 -

STUD WELDING. STUDS SHALL BE TYPE "B", HEADED STUDS, HAVING A MINIMUM

TENSILE STRENGTH OF 60,000 psi, AND SHALL BE OF LENGTH AND DIAMETER

SHOWN ON THE DRAWINGS.

COMPOSITE STEEL FORM DECK:

1. COMPOSITE FORM DECK SHALL BE THE SIZE INDICATED ON STRUCTURAL

DRAWINGS, GAGE G60 CORRUGATED STEEL COMPOSITE DECK AND SHALL

CONFORM TO THE PROVISIONS OF THE STEEL DECK INSTITUTE (SDI)

SPECIFICATIONS FOR COMPOSITE STEEL DECK.

STEEL ROOF DECK:

1. STEEL ROOF DECK SHALL BE THE SIZE INDICATED ON STRUCTURAL

DRAWINGS, PAINTED WIDE RIBBED STEEL ROOF DECK AND SHALL CONFORM TO

THE PROVISIONS OF THE STEEL DECK INSTITUTE (SDI) SPECIFICATIONS FOR

STEEL ROOF DECK.

2. STEEL ROOF DECKS ARE DESIGNED AS HORIZONTAL DIAPHRAGMS AND

SHALL BE ATTACHED TO SUPPORTS IN SDI PATTERNS AS INDICATED ON THE

DRAWINGS.

MASONRY PRISM TESTING:

1. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL CONSTRUCT THREE (3)

TEST PRISMS FOR TESTING. THEY SHALL BE CONSTRUCTED OF TWO (2) 8"x8"x16"

PRISMS FOR TESTING, ONE (1) ON TOP OF THE OTHER, JOINED WITH TYPE "S"

MORTAR, AND FILLED WITH 3,000 psi CONCRETE GROUT. PRISMS SHALL BE CURED

FOR 28 DAYS. NO REINFORCING SHALL BE USED IN THE CONSTRUCTION OF THE

PRISMS.

2. PRISMS SHALL BE MADE OF THE SAME MATERIALS, UNDER THE SAME CONDITIONS,

AND INSOFAR AS POSSIBLE, WITH THE SAME BONDING ARRANGEMENTS AS FOR THE

STRUCTURE. THE MOISTURE CONTENT OF THE UNITS AT THE TIME OF LAYING,

CONSISTENCY OF MORTAR, AND WORKMANSHIP SHALL BE THE SAME AS WILL BE

USED IN THE STRUCTURE. THE VALUE OF f'm SHALL BE THE AVERAGE OF ALL

SPECIMENS TESTED BUT SHALL BE NOT MORE THAN 125 PERCENT OF THE MINIMUM

VALUE DETERMINED BY THE TEST, WHICHEVER IS LESS.

3. TESTING SHALL INCLUDE TESTS IN ADVANCE OF BEGINNING OPERATIONS AS

DESCRIBED ABOVE, AND AT LEAST ONE (1) FIELD TEST DURING CONSTRUCTION FOR

EACH 5,000 SQUARE FEET OF WALL, BUT NOT LESS THAN ONE (1) FIELD TEST

MINIMUM IF TOTAL SQUARE FEET OF WALL FOR ENTIRE PROJECT IS LESS THAN 5,000

SF. ONLY WALLS INDICATED ON STRUCTURAL PLANS NEED BE TESTED.

4. THE COMPRESSIVE STRENGTH, f'm, SHALL BE COMPUTED BY DIVIDING THE

ULTIMATE LOAD BY THE NET AREA OF THE MASONRY USED IN THE CONSTRUCTION

OF THE PRISMS.

5. TEST PRISMS SHALL BE STORED FOR SEVEN DAYS IN AIR, AT A TEMPERATURE OF

70 DEGREES, PLUS OR MINUS 5 DEGREES, IN A RELATIVE HUMIDITY EXCEEDING 90%,

AND THEN IN AIR AT A TEMPERATURE OF 70 DEGREES, PLUS OR MINUM 5 DEGREES,

UNTIL TESTED. THOSE CONSTRUCTED IN THE FIELD SHALL BE STORED

UNDISTURBED FOR FROM 48 TO 96 HOURS UNDER WET MATERIAL TO SIMULATE 90%

HUMIDITY, THEN TRANSPORTED TO LABORATORY FOR CONTINUED CURING AS

DESCRIBED ABOVE.

6. NOT LESS THAN THREE (3) PRISM SPECIMENS SHALL BE MADE FOR EACH FIELD

TEST TO CONFIRM THAT THE MATERIALS ARE AS ASSUMED IN THE DESIGN. THE

STANDARD AGE OF TEST SPECIMENS SHALL BE 28-DAYS, BUT 7-DAY TESTS MAY BE

USED, PROVIDED THE RELATION BETWEEN THE 7-DAY AND 28-DAY STRENGTHS OF

THE MASONRY IS ESTABLISHED BY ADEQUATE TEST DATA FOR THE MATERIALS

USED.

MASONRY MATERIALS:

1. MASONRY UNITS SHALL MEET ASTM C90 TYPE I, GRADE N, FOR HOLLOW LOAD

BEARING TYPE MASONRY WITH A UNIT STRENGTH OF 1,900 psi ON THE NET AREA (f'm

= 1,500 psi).

2. MORTAR SHALL BE TYPE "M" (BELOW GRADE) OR "S" (ABOVE GRADE) AND SHALL

MEET ASTM C270. GROUT SHALL BE 3,000 psi PEA-GRAVEL CONCRETE AND SHALL

MEET ASTM C476. MORTAR MIX DESIGN SHALL BE TESTED PRIOR TO

CONSTRUCTION USING MORTAR TEST CUBES, WITH 7-DAY STRENGTH OF

LABORATORY MIX EXCEEDING THE 28-DAY SPECIFIED DESIGN STRENGTH. GROUT

SHALL BE TESTED PRIOR TO CONSTRUCTED USING PRISMS AS DESCRIBED ABOVE.

MASONRY AND REINFORCED MASONRY PLACEMENT:

1. ALL MASONRY SHALL BE LAID IN RUNNING BOND UNLESS NOTED OTHERWISE.

MATERIALS TO BE LAID AND MATERIALS TO BE BUILT UPON SHALL BE FREE FROM

SNOW AND ICE.

2. PROVIDE HOOKED DOWELS INTO FOOTINGS FOR ALL VERTICAL REINFORCING

ABOVE AS SHOWN IN THE DRAWINGS. LAP SPLICES A MINIMUM OF 48 BAR

DIAMETERS. AT THE OPTION OF THE CONTRACTOR, DOWELS MAY BE DRILLED AND

EPOXIED INTO FOOTING IN LIEU OF HOOKS. EPOXY SHALL BE AS NOTED ON THIS

SHEET UNDER 'CHEMICAL ANCHORS,' 6" MIN. EMBEDMENT FOR #5 OR SMALLER

DOWELS, 8" MIN. EMBEDMENT FOR #6 DOWELS.

3. PROVIDE DUR-O-WALL (OR EQUAL PER SPECIFICATIONS) LADDER OR TRUSS

HORIZONTAL JOINT REINFORCEMENT AT EACH SECOND COURSE IN RUNNING BOND,

AND EACH COURSE IN STACKED BOND, UNLESS NOTED OTHERWISE. DISCONTINUE

HORIZONTAL JOINT REINFORCEMENT AT CONTROL JOINTS.

4. PROVIDE BOND BEAMS REINFORCED WITH (2) #5 BARS EVERY 6'-0" OF VERTICAL

WALL, AT TOPS OF ALL MASONRY WALLS, AND WHERE SHOWN ON DRAWINGS. AT

BOND BEAM CORNERS AND TEE JOINTS, PROVIDE BENT BARS TO MATCH QUANTITY

AND BAR SIZE IN THE BOND BEAM. LAPS IN BOND BEAMS SHALL BE 48 BAR

DIAMETERS OR A MINIMUM OF 2'-0", WHICHEVER IS GREATER.

5. WHERE SHOWN ON THE DRAWINGS, CORES IN CONCRETE BLOCK UNITS SHALL BE

FILLED WITH 3,000 psi CONCRETE GROUT FROM TOP OF FOOTING TO BOTTOM OF

BEARING, OR TO THE TOP OF WALL, DEPENDING ON THE CONDITION. INSPECTION OF

OPENING AT BOTTOM IS REQURIED.

6. WHERE REINFORCING STEEL IS CALLED FOR IN FILLED CORES, IT SHALL EXTEND

FROM TOP OF FOOTING TO BOTTOM OF BEARING, OR TOP OF WALL, DEPENDING ON

CONDITION.

7. WHERE REINFORCING STEEL IS INTERRUPTED BY AN OPENING IN THE WALL, THE

QUANTITY OF BARS INTERRUPTED ARE TO BE MOVED TO EACH SIDE OF THE

OPENING, HALF OF REINFORCING TO ONE SIDE AND REMAINING HALF TO THE OTHER

SIDE. REINFORCING SHALL BE FROM TOP OF FOOTING TO TOP OF WALL. PROVIDE

A MINIMUM OF (2) #5 VERTICAL REINFORCING BARS AT EACH JAMB. SEE PLAN NOTES

AND/OR DETAILS FOR VERTICAL REINFORCING SPACING.

8. WHERE VERTICAL REINFORCING STEEL IS SPLICED IN MASONRY, PROVIDE A

MINIMUM OF 48 BAR DIAMETERS, LAP SPLICE, UNLESS NOTED OTHERWISE.

9. THE MINIMUM DISTANCE BETWEEN PARALLEL BARS, EXCEPT IN COLUMNS, SHALL

BE NOT LESS THAN THE DIAMETER OF THE BAR EXCEPT THAT LAPPED SPLICES MAY

BE WIRED TOGETHER. THE CENTER TO CENTER SPACING OF BARS WITHIN A

COLUMN SHALL BE NOT LESS THAN 2 AND ONE-HALF TIMES THE BAR DIAMETER.

10. ALL BARS SHALL BE COMPLETELY EMBEDDED IN MORTAR OR CONCRETE.

REINFORCEMENT EMBEDDED IN HORIZONTAL MORTAR JOINTS SHALL HAVE NOT LESS

THAN 5/8" MORTAR COVERAGE FROM THE EXPOSED FACE. ALL OTHER

REINFORCING SHALL HAVE A MINIMUM COVERAGE OF ONE BAR DIAMETER OVER ALL

BARS, BUT NOT LESS THAN 3/4", EXCEPT WHERE EXPOSED TO WEATHER OR SOIL IN

WHICH CASE THE MINIMUM COVERAGE SHALL BE 2".

11. WHERE REINFORCING IS SHOWN TO BE LOCATED ALONG TWO FACES OF A

CONCRETE BLOCK WALL, THE CONTRACTOR SHALL BREAK OUT THE SHELL OF THE

LOWEST CONCRETE BLOCK TO GAIN ACCESS TO THE REINFORCING STEEL. THE

REINFORCED STEEL SHALL THEN BE WIRED INTO ITS CORRECT POSITION, AND THE

ACCESS HOLE COVERED. THE CONCRETE GROUT FILL SHALL BE PUDDLED OR

VIBRATED TO ASSURE COMPLETE FILLING OF THE CORE.

12. REINFORCED MASONRY PIERS AND COLUMNS SHALL HAVE THE REINFORCING

STEEL ACCURATELY LOCATED BY WIRING THE TOP AND BOTTOM OF ALL VERTICAL

STEEL INTO ITS CORRECT POSITION. PROVIDE AN ACCESS HOLE AT THE BOTTOM

OF ALL COLUMNS OR PIERS.

13. ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE

UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND

CROSS WEBS FORMING SUCH CELLS TO BE FILLED SHALL BE FULLBEDDED IN

MORTAR TO PREVENT LEAKAGE OF CONCRETE GROUT. ALL HEAD (OR END) JOINTS

SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM THE FACE OF

THE WALL OR UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE

SHELLS. BOND SHALL BE PROVIDED BY LAPPING UNITS IN SUCCESSIVE VERTICAL

COURSES OR BY EQUIVALENT MECHNICAL ANCHORAGE.

A) VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO

MAINTAIN A CLEAR, UNOBSTRUCTED CONTINUOUS VERTICAL CELL MEASURING NOT

LESS THAN 2"x3".

B) CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF ALL CELLS TO BE

FILLED AT EACH POUR OF CONCRETE WHERE SUCH CONCRETE POUR IS IN EXCESS

OF 6' IN HEIGHT. ANY OVERHANGING MORTAR, OTHER OBSTRUCTION OR DEBRIS

SHALL BE REMOVED AND/OR CLEANED AT TIME OF INSPECTION AND PRIOR TO CORE

FILLING. INSPECT AND SEAL ALL OPENINGS BEFORE CONCRETING.

C) VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM

AND AT INTERVALS NOT EXCEEDING 192 DIAMETERS OF THE REINFORCEMENT.

D) ALL CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLIDLY WITH

CONCRETE. CONCRETE SHALL BE POURED IN LIFTS OF 8' MAXIMUM HEIGHT. ALL

CONCRETE SHALL BE CONSOLIDATED AT THE TIME OF POURING BY PUDDLING FOR

LIFTS OF 4' OR LESS, OR BY VIBRATING FOR LIFTS GREATER THAN 4'. CONCRETE

SHOULD LATER BE CONSOLIDATED AGAIN BY PUDDLING, BEFORE PLASTICITY IS

LOST.

E) WHEN TOTAL CONCRETE POUR EXCEEDS 8' IN HEIGHT, THE CONCRETE SHALL BE

PLACED IN 4' MAXIMUM LIFTS. MINIMUM CELL DIMENSION SHALL BE 3".

F) WHEN CONCRETING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL

CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE POUR OF CONCRETE 1

1/2" BELOW THE TOP OF THE UPPERMOST UNIT.

14. PROVIDE A MINIMUM OF 8" BEARING FOR ALL MASONRY LINTELS.

15. WHERE LINTEL BLOCKS ARE USED IN LIEU OF HOLLOW CONCRETE BLOCKS, THE

REINFORCING STEEL SHALL BE ANCHORED TO THE LOWER STEEL OR DOWELS AND

THE LINTEL BLOCKS LAID AROUND THE STEEL. THE CONCRETE FILL SHALL BE

INSTALLED IN LIFTS NOT TO EXCEED 2' IN HEIGHT. THE REINFORCING STEEL SHALL

BE MAINTAINED IN THE SAME POSITION AS THE DOWELS. STOP THE POUR OF THE

CONCRETE 1 1/2" BELOW THE TOP OF THE UPPERMOST UNIT.

16. SPECIFICATION REQUIREMENTS FOR COLD WEATHER AND HOT WEATHER

MASONRY CONSTRUCTION SHALL BE MAINTAINED.

ACI 530-13 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES.

AISI S100-12 NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL

STRUCTURAL MEMBERS

FACTOR AND EXPOSURE LISTED ABOVE.

THE NORTH CAROLINA STATE BUILDING CODE FOR THE BASIC DESIGN WIND VELOCITY, IMPORTANCE

ARE TO BE DESIGNED BY THE MANUFACTURER'S ENGINEER FOR WIND LOADS DETERMINED PER

ALL BUILDING COMPONENTS AND CLADDING ENGINEERED BY THE COMPONENT MANUFACTURER

COMPONENT & CLADDING:

155kVy =

142.5kVx = WIND BASE SHEARS,

IIIRISK CATEGORY

DEXPOSURE CATEGORY

145 mphBASIC WIND SPEED (3 SEC GUST)

WIND:

10 psfSUPERIMPOSED DEAD LOAD

FLOOR:

SNOW LOAD IMPORTANCE FACTOR

0.9Ce = SNOW EXPOSURE FACTOR

11 psfPf = DESIGN ROOF SNOW LOAD

Pg= GROUND SNOW LOAD

20 psfROOF LIVE LOAD

10 psfSUPERIMPOSED DEAD LOAD

ROOF:

SUPERIMPOSED LOADINGS:

THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED WITH THE FOLLOWING

DESIGN LOADS:

DSITE CLASSIFICATION

BDESIGN CATEGORY

E-L-FANALYSIS PROCEDURE USED:

3-1/4R = RESPONSE MODIFICATION FACTOR

.0581Cs = SEISMIC RESPONSE COEFFICIENT

54.7kVy =

54.7kVx = DESIGN BASE SHEARS

SEISMIC RESISTING SYSTEM:

0.096gSd1 =

0.126gSds = SPECTRAL RESPONSE COEFF.,

0.06gS1 =

0.91gSs = MAPPED SPECTRAL RESPONSE ACCELERATIONS,

RISK CATEGORY

1.25Ie =IMPORTANCE FACTOR,

SEISMIC:

1.0Ct = THERMAL FACTOR

1.10Is =

100 psfFLOOR LIVE LOAD (PUBLIC ROOMS & CORRIDORS)

100 psfSTAIRS

III

STEEL ORDINARY CONCENTRICALLY BRACED FRAMES

& INTERMEDIATE REINFORCED MASONRY SHEAR WALLS

10 psf

ROOF LIVE LOAD (PUBLIC) 100 psf

ELEVATED SLABS4,000 psi NWC -

FOUNDATION WALLS5,000 psi NWC -

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

GE

NE

RA

L

NO

TE

S

HMH

HMH

HMH

S0.1

Digitally signed by Heath M. HendrickDate: 2021.01.30 06:13:10 -05'00'

Page 2: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

NOTES:

1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1

2. ELEVATIONS ON THE STRUCTURAL DRAWINGS REFER TO THE TOP OF CONCRETE REFERENCE

ELEVATION SET AT 0'-0"

3. FOR TYPICAL SLAB CONSTRUCTION DETAILS SEE SHEET S3.0.

4. FOR TYPICAL MASONRY WALL CONSTRUCTION DETAILS SEE SHEET S3.1.

5. VERIFY ALL DIMENSIONS & ELEVATIONS WITH ARCHITECTURAL DRAWINGS BEFORE CONSTRUCTION

COMMENCES

6. CENTERLINE OF FOOTING SHALL COINCIDE WITH THE FOUNDATION WALL AND COLUMN

CENTERLINE UNLESS NOTED OTHERWISE.

7. BACKFILL & COMPACT BOTH SIDES OF FOUNDATION WALL SIMULTANEOUSLY.

8. FOR SIZE AND LOCATION OF ROOF, FLOOR, AND WALL OPENINGS SEE MECHANICAL AND

ARCHITECURAL DRAWINGS.

9. MSW-X DENOTES MASONRY SHEARWALLS ABOVE. SEE SHEET S3.1 FOR REINFORCEMENT LAYOUTS.

W12x14F40

BP1-1'-4"

COLUMN SIZE

BASEPLATE MARK

FOOTING MARK

TOP OF FOOTING ELEV.

BELOW FINISHED FLOOR

SCALE: 1/8" = 1'-0"

FOUNDATION PLAN

1

1

3.6

5.5

4.6

2.6

1.8

21

'-6

"2

0'-0

"2

5'-0

"2

0'-0

"2

1'-6

"

1.5

2

3

4

5

6

10

'-4

"6

'-1

0 3

/4

"

4'-3

1

/4

"

8'-7

"

1'-1

1 3

/8

"

9'-3

"1

1'-1

1

/2

"8

'-1

0 1

/2

"1

1'-2

"1

0'-4

"

1

3.6

5.5

4.6

2.6

1.8

1.5

2

3

4

5

6

A.5A B E F

21'-6"

10'-4" 5'-11"

25'-0" 20'-0" 21'-6"

B.3 B.6

5'-10"

1'-4 1/2"

5'-3 1/2" 7'-6"

B.4

3.1

C.1C C.2 C.3

3"

1'-7"

2'-4 1/2"

18'-0 1/2"

11"

1'-7"

D.6 D.7D.5

7'-6"

2'-7"

1'-4 1/2"

5'-10"

E.2 E.5

4'-4 1/2"

6'-9 1/2" 10'-4"

A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8

C.9C.7 DC.8

3"

D.4

D.4

2'-8 1/2"

20'-0"

HSS8x8x3/8F-10.0

BP3-1'-0"

HSS8x8x3/8F-10.0

BP3-1'-0"

HSS8x8x3/8F-10.0

BP3-5'-0"

HSS8x8x3/8F-8.0

BP3-5'-0"

HSS8x8x3/8F-8.0

BP3-5'-0"

W8x31F-6.0

BP3-5'-0"

W8x31F-6.0

BP3-1'-4"

F-7.0

BP3-1'-4"

W8x48F-10.0

BP3-1'-4"

F-7.0

BP3-1'-4"

W8x31F-6.0

BP3-1'-4"

HSS6x6x1/4

BP2

F-7.0

BP3-5'-0"

F-9.0

BP3-5'-0"

F-4.0

BP2-1'-0"

W8x31F-7.0

BP3-1'-4"

W8x31F-8.0

BP3-1'-4"

BP1

W8x31F-7.0

BP3-1'-4"

F-4.0

BP2-1'-0"

W8x31F-8.0

BP3-1'-4"

F-9.0

BP3-1'-0"

F-8.0

BP3-1'-0"

F-4.0

BP2-1'-0"

HSS8x8x3/8

HSS8x8x3/8

HSS8x8x3/8

HSS6x6x1/4

HSS8x8x5/16HSS8x8x5/16

HSS6x6x1/4 HSS6x6x1/4

HSS8x8x5/16

HSS8x8x5/16

W8x31F-5.0

-5'-0" BP3

11

'-8

1

/2

"

3.2

2'-1

1

/8

"

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-5.0

BP3-3'-10"

F-5.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

HSS8x8x1/4

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

F-4.0

BP3-3'-10"

2.1 2.1

2'-6

"

A.8

A.8

5'-3"

HSS8x8x3/8F-9.0

BP3-1'-0"

W8x31F-6.0

-1'-4" BP3

2.8

5'-1

1

/2

"

3'-9

5

/8

"

2.8

3.1

3.2

HSS8x8x1/4

HSS8x8x1/4HSS8x8x1/4

HSS8x8x1/4HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4 HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

HSS8x8x1/4

SCHEDULE

MARK SIZE REINFORCING

F-5.0 5'-0"x5'-0"x18" (6)-#5 E.W. BOT & BOT

F-7.0 7'-0"x7'-0"x18" (12)-#5 E.W. BOT

SPREAD FOOTING

F-8.0 8'-0"x8'-0"x18" (13)-#5 E.W. BOT

F-9.0 9'-0"x9'-0"x24" (14)-#6 E.W. BOT

F-6.0 6'-0"x6'-0"x18" (10)-#5 E.W. BOT

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

F-10.0 10'-0"x10'-0"x24" (16)-#6 E.W. BOT

3'-8

"9

'-9

"

2'-9"

P-1

-1'-4"

P-1

-1'-4"

4'-0"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

P-1

-1'-4"

T.O. SLAB

-5'-0"

BP1

W8x40

6'-6" 6'-6"

5'-6

"

5'-6

"

MF-1

-3'-10"

P-1

-1'-4"

P-1

-1'-4"

F-4.0 HSS8x8x1/4

BP3-3'-10"

F-4.0 HSS8x8x1/4

6'-6" 6'-6"

6'-6

"

6'-6

"

BP1

HSS8x8x3/8

MF-1

-3'-10"

BP1

W8x40

P-1

-1'-4"

F-4.0 4'-0"x4'-0"x18" (5)-#5 E.W. TOP & BOT

W8x48F-10.0

BP3-1'-4"

W8x48F-10.0

BP3-1'-4"

W8x48F-10.0

BP3-1'-4"

P-1

-1'-4"

P-1

-1'-4"

SLAB-ON-GRADE/ AT GRADE

PATIO BEYOND. SEE

ARCHITECTURALS FOR

LAYOUT AND MATERIALS.

SCHEDULE

MARK WIDTH

REINFORCING

MF-2

MAT FOOTING

MF-1 SEE PLAN

SEE PLAN

DEPTH

36"

42"

LONGITUDINAL TRANSVERSE

#7 @ 10" TOP & BOT #7 @ 10" TOP & BOT

#7 @ 8" TOP & BOT #7 @ 8" TOP & BOT

MSW-1 12" CMU

MSW-1 12" CMU

MSW-2 8" CMU

2'-3" 11'-0 3/8" 8'-1 5/8"

4 5

/8

"

4'-8

"

9'-9"

7'-6

"

7'-6"

5'-9

"

7

S3.0

7

S3.0

SIM

6

S3.0

6

S3.0

5

S3.0

TYP. 4

S3.0

TYP.

4

S3.0

TYP.

4

S3.0

TYP.

4

S3.0

TYP.

4

S3.0

TYP.

NOTE:

3 BOLT ROWS TO BE

IN SAME DIRECTION

AS BRACE FRAME.

NOTE:

3 BOLT ROWS TO BE

IN SAME DIRECTION

AS BRACE FRAME.

6

S3.1

TYP.

6

S3.1

TYP.

6

S3.1

TYP.

6

S3.1

TYP.

8

S3.1

8

S3.1

8

S3.1

8

S3.1

5

S3.0

TYP.

SEE

ARCH

EXTENTS OF SLAB STEP.

SEE ARCH FOR STEP DIMENSION.

EXTENTS OF SLAB STEP.

SEE ARCH FOR STEP DIMENSION.

SEE

ARCH

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mo

n law

, statu

tory a

nd oth

er reserved

rights inclu

ding the

copyright the

reto.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

FO

UN

DA

TIO

N P

LA

N

HMH

HMH

HMH

S1.0

Page 3: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

SCALE: 1/8" = 1'-0"

SECOND FLOOR PLAN

1

1

3.6

5.5

4.6

2.6

1.8

21

'-6

"2

0'-0

"2

5'-0

"2

0'-0

"2

1'-6

"

1.5

2

3

4

5

6

10

'-4

"6

'-1

0 3

/4

"

4'-3

1

/4

"

8'-7

"

1'-1

1 3

/8

"

9'-3

"1

1'-1

1

/2

"8

'-1

0 1

/2

"1

1'-2

"1

0'-4

"

1

3.6

5.5

4.6

2.6

1.8

1.5

2

3

4

5

6

A.5A B E F

21'-6"

10'-4" 5'-11"

25'-0" 20'-0" 21'-6"

B.3 B.6

5'-10"

1'-4 1/2"

5'-3 1/2" 7'-6"

B.4

3.1

C.1C C.2 C.3

3"

1'-7"

2'-4 1/2"

18'-0 1/2"

11"

1'-7"

D.6 D.7D.5

7'-6"

2'-7"

1'-4 1/2"

5'-10"

E.2 E.5

4'-4 1/2"

6'-9 1/2" 10'-4"

A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8

C.9C.7 DC.8

3"

D.4

D.4

2'-8 1/2"

20'-0"

5'-0"

CANT.

W24x6235K 30K W27x8482K 80K

15K-FT.

9K

9K

W1

4x2

2 (8

)8

K8

K

W1

4x2

2 (8

)

8K

8K

W1

8x4

0 (8

)2

0K

26

KW

10

x1

2

1'-0

3

/4

"

W1

0x1

2 (8

)

W1

0x1

2 (8

)

W1

0x1

2 (8

)

W1

0x1

2 (8

)

W1

0x1

2

W18x40 (8)15K 13K

W18x3520K 22K 19K 20K W18x40 (8)20K 21K 21K 21K W16x31 (6)20K 17K

W24x68 (6)

39K 41K W18x35 18K 18K

W1

8x3

5W

10

x1

21

5K

21

K

W1

4x2

2 (8

)8

K8

K

W1

8x5

0

11

K

13

K

9K

9K

W1

6x2

6 (1

2)

12

K1

2K

W1

6x2

6 (1

2)

12

K1

2K

W1

8x3

5

17

K1

7K

W1

8x3

5

14

K1

7K

W21x50 (8)

4K

41K W16x26 (6)39K 35K W16x26 (6)19K 32K W16x31 (8)19K W21x44 (12) 31K 27K 34K W16x26

16K

W2

1x5

5 (1

6)

22

K

15

K

13

K1

3K

10

K1

0K

8K

8K

W1

6x2

6 (1

0)

HSS10x10x1/4 COL. ABOVE

W1

0x1

2

W10x12

HSS6x6x1/4 COL. ABOVE

W1

8x3

5 (8

)1

4K

14

K

11

K1

1K

19

K

W2

1x6

2

8K

16

K

8K

W1

6x2

6

W1

6x2

6

11

'-8

1

/2

"

3.2

2'-1

1

/8

"

VF

-2

KB KB KB KB KB KBKB KB KBKB

KBKB KB KB KBKB KB KB KB KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

W16x31 (6) W16x31 (6)

10K

W24x6232K 34K 29K 28K 32K 31K 26K 26K 34K 32KW24x62 W24x62 W24x62W24x62

W1

6x2

6 (1

2)

W1

6x2

6 (1

2)

W1

4x2

2 (8

)7

K7

K

7K

7K

W1

6x2

6 (1

2)

W1

6x3

1 (1

2)

W1

6x2

6 (8

)9

K9

K

W1

0x1

2 (8

)6

K6

K

W1

0x1

2 (8

)7

K7

K

W1

0x1

2 (8

)7

K7

K

W1

0x1

2 (8

)7

K7

K

W1

0x1

2 (8

)7

K7

K

W18x40

13K 15K

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2 (8

)W

10

x1

2

5K

5K

W1

4x2

2W

14

x2

2

KB

KB

W1

6x3

1W

16

x2

6 (6

)

18

K1

8K

18

K1

8K

18

K1

8K

W2

4x6

8 (1

4)

19

K1

9K

W2

4x7

6 (1

4)

21

K2

1K

W2

4x7

6 (1

4)

21

K2

1K

W2

4x7

6 (1

4)

22

K2

2K

W2

4x7

6 (1

4)

23

K

23

K

W2

4x7

6 (1

4)

23

K2

3K

W2

7x8

4 (1

4)

34

K3

4K

W2

4x6

8 (1

4)

20

K2

0K

W2

4x6

8 (1

4)

20

K2

0K

W2

4x6

8 (1

4)

19

K1

9K

W2

4x6

2 (1

4)

18

K1

8K

W2

4x6

2 (1

4)

18

K1

8K

W2

4x6

2 (1

4)

18

K1

8K

W1

6x3

1W

16

x2

6 (6

)

W1

0x1

2

2.1 2.1

2'-6

"

A.8

A.8

5'-3"

W1

W1

W1

W1

FIRST FLOOR LGS EXTERIOR WALL STUD SCHEDULE

MARK ZONE STUD

BOTTOM

TRACK

TOP TRACK

MAX.

HEIGHT

BRACING

W1

4

600S250-54 @ 16" O.C.

600T125-54 600T125-54 15'-4"

CRC w/ BC600 @ 5'-0" O.C. MAX.

5

600S250-54 @ 12" O.C.

600T125-54 600T125-54 15'-4"

CRC w/ BC600 @ 5'-0" O.C. MAX.

W2

4

800S250-54 @ 16" O.C.

800T125-54 800T125-54 15'-4"

CRC w/ BC800 @ 5'-0" O.C. MAX.

5

800S250-54 @ 12" O.C.

800T125-54 800T125-54 15'-4"

CRC w/ BC800 @ 5'-0" O.C. MAX.

2.8 2.8

5'-1

1

/2

"

3'-9

5

/8

"

HSS6x6x1/4 COL. ABOVE

HSS6x6x1/4 COL. ABOVE

44K

4K

HSS6x6x1/4 COL. ABOVE

HSS6x6x1/4 COL. ABOVE

HSS6x6x1/4 COL. ABOVE

3.1

3.2

3K

3K

3K

3K

W1

6x2

6

W16x26

W2

4x6

2 (1

4)

W2

4x6

2 (1

4)

W2

4x6

2 (1

4)

6K

MC

8K

MC

W1

6x3

16

K

MC

7K

MC

W1

6x3

18

K

MC

8K

MC

W1

6x3

19

K

MC

6K

MC

W1

6x3

16

K

MC

8K

MC

W1

6x3

1

6K

MC

8K

MC

W1

6x3

16

K

MC

7K

MC

W1

6x3

18

K

MC

8K

MC

W1

6x3

19

K

MC

6K

MC

W1

6x3

16

K

MC

8K

MC

W1

6x3

1

6K

MC

6K

MC

9K

MC

7K

MC

8K

MC

8K

MC

7K

MC

9K

MC

6K

MC

6K

MC

W16x31 W16x31 W16x31 W16x31 W16x31

6K

MC

6K

MC

9K

MC

7K

MC

8K

MC

8K

MC

7K

MC

9K

MC

6K

MC

6K

MC

W16x31 W16x31 W16x31 W16x31 W16x31

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W10x26 W10x26

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W10x26 W10x26

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K

4K 4

K

4K

4K

4K

4K

4K

5K 5K 5K5K

W10x12 5K5K

W10x12 4K4K

W10x12 4K4K

W10x124K

W10x12 4K4K

W10x12 4K4K

W10x12 4K4K

W10x12 3K3K

W10x12 3K3K

W10x12 3K3K

5K5K

W10x12 5K5K

W10x12 4K4K

W10x12 4K4K

W12x16 4K4K

W1

2x1

61

K1

K

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W10x12

W12x16

W1

2x1

6

5K5K

4K4K

4K4K

4K

4K

3K

4K 4K

4K

4K

4K 4K

4K

3K

3K3K

3K3K

1K

1K

4K4K

4K4K

4K4K

5K5K

5K5K

12

K1

2K

12

K1

2K

7K

6K

5K

6K

12

K1

5K

12

K1

2K

6K

3K

3K

4K

4K

4K

4K

4K

3K

6K

5K

5K

5K

5K

4K

5K

4K

5K

5K

5K

3K

6K

6K

6K

6K

6K

6K

6K

6K

3K

1

K

1

K

3K

3K

NOTES:

1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1

2. SEE ARCH FOR ALL DIMENSIONS NOT PROVIDED ON THIS SHEET.

3. TOP OF 2ND FLOOR STEEL, (T.O.S.) = +16'-8" UNLESS NOTED OTHERWISE, (U.N.O.)

4. ELEVATED SLAB TO BE 4" NW CONCRETE OVER 2VLI22 COMPOSITE DECK. SEE DETAIL

2/S4.0 FOR TYPICAL STUD PLACEMENT DETAILS.

5. MC DENOTES MOMENT CONNECTION - SEE DETAIL 6/S4.0.

6. TYPICAL COMPOSITE BEAM NOTATION:

VF

-1

ORNAMENTAL

STAIR BY

OTHERS.

SEE ARCH.

W18X46 (18)42K 42K

LEFT SHEAR

REACTION

BEAM SIZE # SHEAR STUDS

(UNIFORMLY SPACED)

RIGHT SHEAR

REACTION

*IF NO REACTIONS ARE PROVIDED, CONNECTIONS ARE TO BE

DESIGNED FOR MINIMUM SHEAR REACTION OF 4K

5K

5K

H2 H2 H2H2 H2

H1

AH

2

H2

H4

A

H2 H2 H2H2 H2

H1

AH

1A

H2

H2

NOTE:

ALL PORCH FRAMING T.O. STEEL ELEVATION TO BE -0'-1"

BELOW TYPICAL 2ND FLOOR TOP OF STEEL.

W2

W1

W1

W2

W1

NOTE:

HATCHED AREA INDICATED AREA OF MECHANICAL

MEZZANINE BELOW FRAMING. SEE MECHANICAL

MEZZANINE PLANS FOR FRAMING REQUIREMENTS AND

ELEVATION.

W1

0x1

2

5K

W1

0x1

2 (8

)

5K

W12x14 (8) 11K 9K

5

S4.0

10

S4.1

7

S4.0

TYP.

7

S4.0

TYP.

7

S4.0

TYP.

7

S4.0

TYP.

T.O.S. = +14'-11 7/8" T.O.S. = +14'-11 7/8" T.O.S. = +14'-11 7/8"T.O.S. = +14'-11 7/8"T.O.S. = +14'-11 7/8"

T.O. W16x26 = +14'-11 7/8" T.O. W16x26 = +14'-11 7/8"

17

S4.1

TYP.

W10x12

2K 2K

W10x12

2K 2K

W10x12

2K 2K

W10x12

2K 2K

W12x16 4K3KW12x16 3K4K

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

SE

CO

ND

F

LO

OR

FR

AM

IN

G P

LA

N

HMH

HMH

HMH

S1.1

Page 4: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

HSS10X10X5/8

1

3.6

5.5

4.6

2.6

1.8

21

'-6

"2

0'-0

"2

5'-0

"2

0'-0

"2

1'-6

"

1.5

2

3

4

5

6

10

'-4

"6

'-1

0 3

/4

"

4'-3

1

/4

"

8'-7

"5

'-1

1

/2

"

1'-1

1 3

/8

"

11

'-8

1

/2

"9

'-3

"1

1'-1

1

/2

"8

'-1

0 1

/2

"1

1'-2

"1

0'-4

"

1

3.6

5.5

4.6

2.6

1.8

1.5

2

3

4

5

6

A.5A B E F

21'-6"

10'-4" 5'-11"

25'-0" 20'-0" 21'-6"

B.3 B.6

5'-10"

1'-4 1/2"

5'-3 1/2" 7'-6"

B.4

3.1

C.1C C.2 C.3

3"

1'-7"

2'-4 1/2"

18'-0 1/2"

11"

1'-7"

D.6 D.7D.5

7'-6"

2'-7"

1'-4 1/2"

5'-10"

E.2 E.5

4'-8 3/8"

6'-5 5/8" 10'-4"

A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8

C.9C.7 DC.8

3"

D.4

D.4

2'-8 1/2"

20'-0"

PRE-FABRICATED CFS ROOF TRUSSES

@ 24"oc (MAX.) (DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)

PRE-FABRICATED CFS ROOF TRUSSES @ 24"oc (MAX.)

(DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)

PR

E-F

AB

RIC

AT

ED

C

FS

R

OO

F T

RU

SS

ES

@

2

4"o

c (M

AX

.)

(D

ES

IG

N F

OR

N

ET

U

PL

IF

T P

RE

SS

UR

E =

2

8 P

SF

)

PR

E-F

AB

RIC

AT

ED

C

FS

R

OO

F T

RU

SS

ES

@

2

4"o

c (M

AX

.)

(D

ES

IG

N F

OR

N

ET

U

PL

IF

T P

RE

SS

UR

E =

2

8 P

SF

)

3.2

2'-1

1

/8

"

PRE-FABRICATED (SLOPED) CFS ROOF TRUSSES

@ 24"oc (MAX.) (DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)

SCALE: 1/8" = 1'-0"

ROOF FRAMING PLAN

1

VF

-2

KB KB KB KB KB KBKB KB KBKB

KBKB KB KB KBKB KB KB KB KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

KB

W16x26 (6)13K 18K 21K 19K W18x40 (8)23K 23K 17K 18K W16x26 (6)20K 16KW16x26 (6) W16x26 (6)

W24x6827K 36K W33x11854K 60K W12x14 W24x55 (12)29K 29K

W24x62

4K

39K W24x6218K 36K W24x6219K 32K W24x6218K W24x62 36K 27K 32K W24x62

14K 8K

W24x6231K 31K 26K 25K 29K 29K 23K 23K 30K 30KW24x62 W24x62 W24x62W24x62

W1

6x3

1

11

K1

1K

W1

8x4

01

1K

11

KW

14

x2

2 (6

)W

14

x2

2 (6

)

4K

W1

0x1

2 (8

)6

K

9K

W1

4x2

2 (8

)9

K

9K

W1

6x2

69

K

10

KW

16

x2

61

0K

W1

4x2

2 (8

)8

K8

K

W1

0x1

2 (8

)W

10

x1

2

W1

6x2

6 (1

2)

12

K1

2K

W1

6x2

6 (1

2)

12

K1

2K

W1

6x2

6 (1

2)

12

K1

2K

W1

0x1

2 (8

)W

10

x1

2

4K

4K

4K

4K

W1

4x2

2 (8

)

8K

8K

W1

0x1

2 (8

)W

10

x1

2

10

K

W1

6x2

6

10

K

W1

6x3

6 (1

0)

9K

9K

W1

6x2

6 (8

)1

0K

10

K

W1

6x2

6 (8

)1

0K

10

K

W1

6x2

6 (1

0)

11

K1

1K

W1

6x3

1 (1

2)

14

K1

3K

W1

6x3

1 (1

2)

14

K1

3K

W1

6x3

1 (1

2)

14

K1

3K

W1

6x3

1 (1

2)

14

K1

3K

W1

6x3

1 (8

)1

4K

12

K

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

W1

0x1

2

KB

KB

W1

4x2

2W

14

x2

2

W2

4x7

6

18

K1

8K

W2

4x6

2 (1

4)

19

K1

9K

W2

4x6

8

18

K1

8K

W2

4x6

8

18

K1

8K

W2

4x7

6 (1

4)

22

K2

2K

W2

4x7

6 (1

4)

22

K2

2K

W2

4x7

6 (1

4)

22

K2

2K

W2

4x7

6 (1

4)

23

K2

3K

W2

4x7

6 (1

4)

23

K2

3K

W2

4x6

8 (1

4)

21

K2

1K

W2

4x6

8 (1

4)

20

K2

0K

W2

4x6

8 (1

4)

20

K2

0K

W2

4x6

8 (1

4)

20

K2

0K

W2

4x6

2 (1

4)

20

K2

0K

W2

4x6

2 (1

4)

20

K2

0K

W2

4x6

2 (1

4)

20

K2

0K

W1

4x2

2 (6

)W

14

x2

2 (6

)

2.1 2.1

2'-6

"

A.8

A.8

5'-3"

W1

0x1

2

4K

6K

2.8

3'-9

5

/8

"

3.1

3.2

2.8

45K

15K

W1

6x3

1 (1

2)

14

K1

2K

W1

6x2

6

EXTENT OF ROOFTOP

BAR FLOOR AREA ABOVE

W24x62

2K

2K

W1

0x1

2

9K

9K

6K

6K

6K

6K

7K 6K

10

KW

16

x2

61

0K

10

KW

16

x2

61

0K

10

KW

16

x2

61

0K

10

KW

16

x2

61

0K

W12x222K

MC

4K

MC

4K

MC

3K

MC

W12x22 9K

MC

9K

MC

W16x36 3K

MC

4K

MC

W12x22 W12x224K

MC

2K

MC

W1

2x2

2

W1

2x2

2

W1

2x2

2

W1

2x2

2

W1

2x2

2

2K

2K

4K

4K

5K

5K

5K

5K

4K

4K

2K

2K

W1

2x2

22

K

MC

4K

MC

3K

MC

4K

MC

W1

2x2

24

K

MC

3K

MC

W1

2x2

63

K

MC

3K

MC

W1

2x2

63

K

MC

2K

MC

W1

2x2

6

W12x222K

MC

4K

MC

3K

MC

W12x22 3K

MC

4K

MC

4K

MC

W12x22 3K

MC

3K

MC

W12x22 4K

MC

2K

MC

W12x22

3K

MC

2K

MC

W1

2x2

63

K

MC

3K

MC

W1

2x2

64

K

MC

3K

MC

W1

2x2

63

K

MC

4K

MC

W1

2x2

2W

12

x2

22

K

MC

4K

MC

9K

9K

9K

9K

4K

4K

5K

4K

9K

9K

9K

9K

3K

3K

4K

3K

5K

4K

5K

5K

4K

4K

3K

3K

4K

3K

5K

5K

5K

5K

5K

5K

5K

5K

6K

6K

6K

4K

4K

NOTES:

1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1

2. SEE ARCH FOR ALL DIMENSIONS NOT PROVIDED ON THIS SHEETS.

3. TOP OF ROOF LEVEL STEEL (T.O.S.) = +33'-8" UNLESS NOTED OTHERWISE (U.N.O.)

4. ELEVATED SLAB TO BE 4" NW CONCRETE OVER 2VLI22 COMPOSITE DECK. SEE DETAIL

2/S4.0 FOR TYPICAL STUD PLACEMENT DETAILS.

5. MC DENOTES MOMENT CONNECTION - SEE DETAIL 6/S4.0.

6. TYPICAL COMPOSITE BEAM NOTATION:

(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")

(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")(T.O.S. = 30'-3")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

(T

.O

.S

. =

3

0'-3

")

VF

-1

W18X46 (18)42K 42K

LEFT SHEAR

REACTION

BEAM SIZE # SHEAR STUDS

(UNIFORMLY SPACED)

RIGHT SHEAR

REACTION

*IF NO REACTIONS ARE PROVIDED, CONNECTIONS ARE TO BE

DESIGNED FOR MINIMUM SHEAR REACTION OF 4K

H3 H3 H3 H3 H3

H3 H3 H3 H3 H3

H1

BH

3H

3

H1

BH

3H

3

W1

2x2

2

W12x22

(T.O.S. = 30'-3")

W1

W1

W1

W2

W1

W1

W2

W1

NOTE:

HATCHED AREA INDICATED AREA OF MECHANICAL

MEZZANINE BELOW FRAMING. SEE MECHANICAL

MEZZANINE PLANS FOR FRAMING REQUIREMENTS AND

ELEVATION.

SECOND FLOOR LGS EXTERIOR WALL STUD SCHEDULE

MARK ZONE STUD

BOTTOM

TRACK

TOP TRACK

MAX.

HEIGHT

BRACING

W1

4

600S250-54 @ 16" O.C.

600T125-54 600T125-54 15'-4"

CRC w/ BC600 @ 5'-0" O.C. MAX.

5

600S250-54 @ 12" O.C.

600T125-54 600T125-54 15'-4"

CRC w/ BC600 @ 5'-0" O.C. MAX.

W2

4

800S250-54 @ 16" O.C.

800T125-54 800T125-54 15'-4"

CRC w/ BC800 @ 5'-0" O.C. MAX.

5

800S250-54 @ 12" O.C.

800T125-54 800T125-54 15'-4"

CRC w/ BC800 @ 5'-0" O.C. MAX.

W1

0x1

2

W1

0x1

2

5K

4K

W1

0x1

24

K

W1

0x1

24

K

4K

4K

W12x14 (6)

14K 9K

HSS6x6x1/4 COL. ABOVE

15

S4.1

TYP.

15

S4.1

TYP.

15

S4.1

TYP.

15

S4.1

TYP.

15

S4.1

TYP.16

S4.1

16

S4.1

17

S4.2

17

S4.2

17

S4.2

SIM

17

S4.2

17

S4.2

SIM

EXTENT OF ROOFTOP

BAR FLOOR AREA ABOVE

HSS6x6x1/4 COL. ABOVE

HSS6x6x1/4 COL. ABOVE

HSS6x6x1/4

COL. ABOVE

HSS6x6x1/4

COL. ABOVE

HSS6x6x1/4

COL. ABOVE HSS6x6x1/4 COL. ABOVE

HSS6x6x1/4 COL. ABOVE

19

S4.2

TYP

GIRDER TRUSS

GIRDER TRUSS

GIRDER TRUSS

GIRDER TRUSS

GIRDER TRUSS

GIRDER

TRUSS

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

MA

IN

R

OO

F

FR

AM

IN

G P

LA

N

HMH

HMH

HMH

S1.2

Page 5: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

HSS

12x6x1/4

SCALE: 1/8" = 1'-0"

HIGH ROOF FRAMING PLAN

1

1

3.6

5.5

4.6

2.6

1.8

21

'-6

"2

0'-0

"2

5'-0

"2

0'-0

"2

1'-6

"

1.5

2

3

4

5

6

10

'-4

"6

'-1

0 3

/4

"

4'-3

1

/4

"

8'-7

"

1'-1

1 3

/8

"

9'-3

"1

1'-1

1

/2

"8

'-1

0 1

/2

"1

1'-2

"1

0'-4

"

A.5A B E F

21'-6"

10'-4" 5'-11"

25'-0" 20'-0" 21'-6"

B.3 B.6

5'-10"

1'-4 1/2"

5'-3 1/2" 7'-6"

B.4

3.1

C.1C C.2 C.3

3"

1'-7"

2'-4 1/2"

18'-0 1/2"

11"

1'-7"

D.6 D.7D.5

7'-6"

2'-7"

1'-4 1/2"

5'-10"

E.2 E.5

4'-8 3/8"

6'-5 5/8" 10'-4"

A.5A B E FB.3 B.6B.4 C.1C C.2 C.3 C.9C.7 D D.6 D.7D.5 E.2 E.5C.8

C.9C.7 DC.8

3"

D.4

D.4

2'-8 1/2"

20'-0"

11

'-8

1

/2

"

3.2

2'-1

1

/8

"

1

3.6

5.5

4.6

2.6

1.8

1.5

2

3

4

5

6

MC MC MC MC MC MC

MC MC MC MC MC MC MC MC

MC

MC

MC

MC

MC

MC

1K

1K

2.1 2.1

2'-6

"

A.8

A.8

5'-3"

MCMC

2.8 2.8

5'-1

1

/2

"

3'-9

5

/8

"

3.1

3.2

6K 6K 4K 4K 6K 6K 3K 1K 2K 2K

1K1K

1K

1K

1K

1K

3K 1K10K 7K7K 10K

1K

1K

1K

1K

1K

1K

NOTES:

1. FOR GENERAL NOTES AND ABBREVIATIONS, SEE S0.1

2. SEE ARCH FOR ALL DIMENSIONS NOT PROVIDED ON THIS SHEETS.

3. TOP OF HIGH ROOF STEEL (T.O.S.) = +45'- 1 1/8" UNLESS NOTED OTHERWISE (U.N.O.)

4. HIGH ROOF TO BE 1.5PLB22 OVER PREFABRICATED METAL ROOF TRUSSES.

5. MC DENOTES MOMENT CONNECTION - SEE DETAIL 6/S4.0.

6. TYPICAL COMPOSITE BEAM NOTATION:

W18X46 (18)42K 42K

LEFT SHEAR

REACTION

BEAM SIZE # SHEAR STUDS

(UNIFORMLY SPACED)

RIGHT SHEAR

REACTION

*IF NO REACTIONS ARE PROVIDED, CONNECTIONS ARE TO BE

DESIGNED FOR MINIMUM SHEAR REACTION OF 4K

PREFABRICATED ROOF TRUSSES BY OTHERS

(DESIGN FOR NET UPLIFT PRESSURE = 28 PSF)

- SEE ARCH/MEP FOR ROOFTOP MECHANICAL

REQUIREMENTS AND PENETRATIONS, TYPICAL.

ORNAMENTAL

GAZEBO STRUCTURE BY

OTHERS - SEE ARCH FOR FINAL

LAYOUT AND MATERIALS.

1.5PLB22 ROOF DECK

OVER 10K1 BAR JOISTS @

24" O.C. OVER ELEVATOR

SHAFTS, TYP.

W1

2x1

4

W12x14

H6

H6H6

H6H5H6H7H6

H6

H6

ROOF LGS EXTERIOR WALL STUD SCHEDULE

MARK ZONE STUD

BOTTOM

TRACK

TOP TRACK

MAX.

HEIGHT

BRACING

W1

4

600S250-54 @ 16" O.C.

600T125-54 600T125-54 15'-4"

CRC w/ BC600 @ 5'-0" O.C. MAX.

5

600S250-54 @ 12" O.C.

600T125-54 600T125-54 15'-4"

CRC w/ BC600 @ 5'-0" O.C. MAX.

W2

4

800S250-54 @ 16" O.C.

800T125-54 800T125-54 15'-4"

CRC w/ BC800 @ 5'-0" O.C. MAX.

5

800S250-54 @ 12" O.C.

800T125-54 800T125-54 15'-4"

CRC w/ BC800 @ 5'-0" O.C. MAX.

KB

KB

KB

KB

W1

W1

W1

W1

W1

HSS

12x6x1/4

HSS

12x6x1/4

HSS

12x6x1/4

HSS

12x6x1/4

HSS

12x6x1/4

HS

S

12

x6

x1

/4

HSS

12x6x1/4

HSS

12x6x1/4

HSS

12x6x1/4

HS

S

12

x6

x1

/4

HS

S

12

x6

x1

/4

HS

S

12

x6

x1

/4

HS

S

12

x6

x1

/4

HS

S

12

x6

x1

/4

NOTE:

ALL ROOFTOP BAR LEVEL

COLUMNS TO BE HSS 6x6x1/4

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

HIG

H R

OO

F

FR

AM

IN

G P

LA

N

HMH

HMH

HMH

S1.3

Page 6: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

A.5

1.5

1.8

2

2.1

2.6

3

3.1

3.2

A.8 B B.3 B.6 C C.1 C.2

1.5

1.8

2

2.1

2.6

3

3.1

3.2

A.5 A.8 B B.3

B.4

B.6 C C.1 C.2B.4

1000S162-54 @ 16" O.C.

1000S162-54 @ 16" O.C.

1000S162-54 @ 16" O.C.

10

00

S1

62

-5

4 @

1

6" O

.C

.

10

00

S1

62

-5

4 @

1

6" O

.C

.

10

00

S1

62

-5

4 @

1

6" O

.C

.

10

00

S1

62

-5

4 @

1

6" O

.C

.

SCALE: 1/4" = 1'-0"

FIRST FLOOR MECHANICAL MEZZANINE PLAN

1

W3

W2

W3

W3

W4

W3

W4

W3

W3

W4

W4

W3

H8 H8 H8

H1

0H

10

H11

NOTES:

1. T.O. LGS JOIST ELEVATION = +9'-4" UNLESS NOTED OTHERWISE (U.N.O.)

2. TYPICAL MEZZANINE FLOOR TO BE 0.6C26 METAL DECK w/ 1" TOPPING. (TOTAL THICKNESS = 1-5/8". SEE DETAIL 13/S4.1)

H1

1

1000S162-97 AT FLOOR

OPENING

HSS10X10X5/8

A.5

1.5

1.8

2

2.1

2.6

3

3.1

3.2

A.8 B B.3 B.6 C C.1 C.2

1.5

1.8

2

2.1

2.6

3

3.1

3.2

A.5 A.8 B B.3

B.4

B.6 C C.1 C.2B.4

10

00

S1

62

-5

4 @

1

6" O

.C

.

1000S162-54 @ 16" O.C.

1000S162-54 @ 16" O.C.

SCALE: 1/4" = 1'-0"

SECOND FLOOR MECHANICAL MEZZANINE PLAN

2

W4

W3

W3

W3

W1

W2

H8 H8

H8 H9

NOTES:

1. T.O. LGS JOIST ELEVATION = +26'-4" UNLESS NOTED OTHERWISE (U.N.O.)

2. TYPICAL MEZZANINE FLOOR TO BE 0.6C26 METAL DECK w/ 1" TOPPING. (TOTAL THICKNESS = 1-5/8". SEE DETAIL 13/S4.1)

1000S162-97 AT FLOOR

OPENING

MECHANICAL MEZZANINE WALL STUD SCHEDULE

MARK STUD

MAX.

HEIGHT

BOTTOM TRACK TOP TRACK BRACING

W3

362S200-43 @ 16" O.C.

16'-8" 362T125-43 362T125-43

CRC w/ BC1 @ 5'-0" O.C. MAX.

W4

600S162-43 @ 16" O.C.

16'-8" 600T125-43 600T125-43

CRC w/ BC1 @ 5'-0" O.C. MAX.

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

FR

AM

IN

G P

LA

NS

ME

CH

AN

IC

AL

PLA

TF

OR

M

HMH

HMH

HMH

S1.4

Page 7: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

16'-8"

T.O. STEEL

1.5 2.6

33'-8"

T.O. STEEL

0'-0"

F.F.E.

SCALE: 1/2" = 1'-0"

VF-1 ELEVATION (VIEWED FROM EXTERIOR)

1

16'-8"

T.O. STEEL

1.52.6

33'-8"

T.O. STEEL

0'-0"

F.F.E.

SEE PLAN

T.O. SLAB

SCALE: 1/2" = 1'-0"

VF-2 ELEVATION (VIEWED FROM EXTERIOR)

2

WIDE FLANGE BEAM. SEE PLAN.

WIDE FLANGE BEAM. SEE PLAN.

H

S

S

8

x

8

x

1

/

4

M

A

X

T

/

C

=

7

7

K

(

1

.

0

W

)

WID

E F

LA

NG

E C

OL

UM

N. S

EE

P

LA

N.

HS

S C

OL

UM

N. S

EE

P

LA

N.

WIDE FLANGE BEAM. SEE PLAN.

WIDE FLANGE BEAM. SEE PLAN.

H

S

S

8

x

8

x

1

/

4

M

A

X

T

/

C

=

7

7

K

(

1

.

0

W

)

WID

E F

LA

NG

E C

OL

UM

N. S

EE

P

LA

N.

HS

S C

OL

UM

N. S

EE

P

LA

N.

H

S

S

8

x

8

x

1

/

4

M

A

X

T

/

C

=

1

3

0

K

(

1

.

0

W

)

SEE PLAN

T.O. SLAB

H

S

S

8

x

8

x

1

/

4

M

A

X

T

/

C

=

1

3

0

K

(

1

.

0

W

)

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

BR

AC

E F

RA

ME

ELE

VA

TIO

NS

HMH

HMH

HMH

S2.0

Page 8: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

PREPARE SLAB SUBGRADE AS PER

THE GEOTECHNICAL ENGINEER'S

RECOMMENDATIONS

4" GRANULAR BASE, PER THE

GEOTECHNICAL ENGINEER'S

RECOMMENDATIONS

4" CONC SLAB

NOTES:

1. SEE ARCHITECTURAL DRAWINGS FOR SLOPES, DROPS,

AND DRAIN LOCATIONS IN FLOOR SLABS.

VAPOR BARRIER, SEE ARCH DWGS

6"x6" - W2.9xW2.9 WELDED WIRE

MESH. WELDED WIRE MESH MUST

BE PREFABRICATED SHEETS, NO

ROLLED MESH ALLOWED. PROVIDE

A MINIMUM OF ONE CHAIR PER 25

SQ. FT. OF MESH SUPPORTED

NOTES:

1. CONTRACTORS OPTION - USE REMOVABLE CONTROL JOINT MATERIAL SUCH AS

"ZIP STRIP", "STRESSLOCK", OR APPROVED EQUAL.

2. SLAB ON GRADE CONTROL JOINTS SHALL BE TOOLED OR SAWCUT. THE JOINT

PATTERN SHALL BE APPROXIMATELY SQUARE AND LIMITED TO AN AREA NOT TO

EXCEED 225 S.F. JOINTS SHALL BE CUT WITHIN 12 HOURS OF POURING SLAB. SEE

PLAN FOR PROPOSED JOINT LAYOUT. FINAL JOINT LAYOUT TO BE DETERMINED BY

THE GENERAL CONTRACTOR.

3/16" SAWCUT CONTROL JOINT. HAND CUT ENDS TO

3/4" MAX. FROM VERTICAL SURFACES. CLEAN JOINT

AND FILL w/ ELASTOMERIC JOINT SEALANT, CUT

JOINT TO A DEPTH OF 1/4 OF THE SLAB THICKNESS

SLAB REINFORCING, SEE TYP

SLAB ON GRADE DETAIL

CONSTRUCTION JOINT TO HAVE A TOOLED

1/8" MAX. EDGE RADIUS IN ALL AREAS

WHERE SLAB IS EXPOSED TO VIEW. CLEAN

JOINT AND FILL WITH ELASTOMERIC JOINT

SEALANT, UNLESS NOTED OTHERWISE.

SLAB REINFORCING, SEE

TYP SLAB ON GRADE DETAIL

1'-0" 8" 1'-0"

8"

2'-4"x2'-4" SUMP BASE

w/ (4) #4 HAIRPINS

EACH WAY

CONC. SLAB ON GRADE

SEE DTL.

PREPARE SUBGRADE PER

THE GEOTECHNICAL ENGINEER'S

RECOMMENDATIONS

12" CMU SHEARWALL (8" CMU SIM.)

SEE PLAN FOR REINF.

(-5'-0")

T.O.F.

(0'-0")

F.F.E.

NOTE:

CONFIRM REQUIRED PIT

DEPTH WITH ELEVATOR

MANUFACTURER

MAT FOUNDATION BELOW

ELEVATOR - SEE PLAN

FOR EXTENTS.

SE

E

SC

HE

DU

LE

#5 HORIZ. @ 12" O.C.

#6 VERT. @ 12" O.C. TYP.

#6 @ 8" O.C. TO MATCH QUANTITY OF CHORD

REINFORCEMENT OF SHEAR WALL CHORDS

ABOVE. SEE MASONRY WALL SCHEDULES

AND REINFORCEMENT DETAILS.

NOTE:

8" CIP STEM WALL REQUIRES

(1) ROW OF REINFORCEMENT

ONLY (CENTERED).

(1) #4 EDGE BAR,

TYP

#3 HOOKS @ 18"

O.C., TYP

#6 VERT. @ 12" O.C. TYP.

#6 @ 8" O.C. TO MATCH QUANTITY

OF CHORD REINFORCEMENT OF

SHEAR WALL CHORDS ABOVE. SEE

MASONRY WALL SCHEDULES AND

REINFORCEMENT DETAILS.

2'-4"x2'-4" SUMP BASE

w/ (4) #4 HAIRPINS

EACH WAY

16"dia ELEVATOR PIT SUMP w/

#5 x 5'-0"L ADDT'L. REINF. ALONGSIDE

OPENING T&B (TYP EACH WAY)

SEE PLAN

8"

TY

P

#5 HORZ REBAR @

12" O.C.

PREPARE SUBGRADE PER

THE GEOTECHNICAL ENGINEER'S

RECOMMENDATIONS

(-5'-0")

T.O.F.

NOTE:

CONFIRM REQUIRED PIT

DEPTH WITH ELEVATOR

MANUFACTURER

(1) #4 EDGE BAR,

TYP

#3 HOOKS @ 18"

O.C., TYP

MAT FOUNDATION BELOW

STAIR TOWERS - SEE

PLAN FOR EXTENTS.

SE

E

SC

HE

DU

LE

#5 HORIZ. @ 12" O.C.

#6 VERT. @ 12" O.C. TYP.

#6 @ 8" O.C. TO MATCH QUANTITY OF CHORD

REINFORCEMENT OF SHEAR WALL CHORDS

ABOVE. SEE MASONRY WALL SCHEDULES

AND REINFORCEMENT DETAILS.

MAT FOUNDATION BELOW

STAIR TOWERS - SEE

PLAN FOR EXTENTS.

VARIES

MATCH CMU WIDTH ABOVE.

SCALE: 3/4" = 1'-0"

CAST-IN-PLACE CONCRETE PEDESTIALS (P-1)

4

ELEVATION

HSS-COLUMN & WIDE FLANGE

COLUMN, SEE PLAN

C

L

COLUMN BASEPLATE ON 1 1/2" GROUT

BED. FASTEN TO FOOTING W/ (4) 3/4" Ø

SIMPSON PAB6 W/ LEVELING NUTS

SE

E

PL

AN

COLUMN FOOTING

SEE PLAN

2"

#4

T

IE

S @

1

2"o

.c.

(M

AX

)

2"

2"

(2)-LATERAL TIES AT TOP OF

PEDESTAL AS SHOWN (TYP.)

A

SEE PLAN

16"dia ELEVATOR PIT SUMP w/

#5 x 5'-0"L ADDT'L. REINF. ALONGSIDE

OPENING T&B (TYP EACH WAY)

#3 HOOKS @ 18"

O.C., TYP

8"

TY

P

#3 HOOKS @ 16"

O.C., TYP

(1) #4 EDGE BAR,

TYP

(1) #4 EDGE BAR,

TYP

3'-4

"

SEE PLAN

CONC. SLAB ON GRADE

SEE DTL.

#5 HORIZ. @ 12" O.C.

#6 VERT. @ 12" O.C. TYP.

#6 @ 8" O.C. TO MATCH QUANTITY OF CHORD

REINFORCEMENT OF SHEAR WALL CHORDS

ABOVE. SEE MASONRY SHEAR WALL

SCHEDULE AND REINFORCEMENT DETAILS.

#3 HOOKS @ 18"

O.C., TYP

8"

TY

P

#3 HOOKS @ 16"

O.C., TYP

(1) #4 EDGE BAR,

TYP

(1) #4 EDGE BAR,

TYP

3'-4

"

8" CMU WALL w/ #6 VERT @ 40" oc -

GROUT SOLID ALL CELLS (TYP.)

#6x72" DOWEL, ALIGN w/

CMU WALL VERT. REBAR

3'-4

"

(0'-0")

F.F.E.

(2) #6x72" DOWEL, ALIGN w/

CMU WALL VERT. REBAR. (1 #6x72"

DOWEL FOR 8" CMU)

3"

2"

3"

2"

8"

TYP

8"

TYP

(0'-0")

F.F.E.

SEE PLAN

T.O. PEDESTAL

SEE PLAN

T.O. FOOTING

SECTION A

2'-6

"

2'-6"

EXTENT OF COLUMN

BASEPLATE ABOVE

(HSS SIMILAR)

(8)-#6 VERT.

#4 TIES @ 12"o.c.

HSS COLUMN & WIDE FLANGE COLUMN, SEE PLAN

SLAB-ON-GRADE

(TYP.)

C

L

SE

E

PL

AN

3"

COLUMN BASEPLATE ON 1 1/2" GROUT

BED. FASTEN TO FOOTING W/ SPECIFIED

ANCHOR BOLTS W/ LEVELING NUT &

HEAVY HEX WASHER. SEE BASEPLATE

SCHEDULE FOR FASTENER SIZE, COUNT,

AND EMBEDMENT.

1 1

/2

"

COLUMN ISOLATION JOINT

POUR SOLID ONCE COLUMN

IS ERECTED AND PLUMB

COLUMN FOOTING/SLAB

SEE PLAN

COLUMN BASEPLATE

SCHEDULE

MARK B H

BP2 12"

THICKNESS

12" 3/4"

2"

BP3 14" 14" 3/4"

B

H

1 1

/2

"

1 1/2"

(4) 3/4" DIA. SIMPSON

PAB6 ANCHOR BOLTS

(TYP.) (8" EMBEDMENT)

COLUMN BASEPLATE

- SEE SCHEDULE

HSS-COLUMN &

W-COLUMN, SEE PLAN

SCALE: 3/4" = 1'-0"

SECTION - TYPICAL COLUMN & BASE PLATE

5

B

H

1 1

/2

"

1 1/2"

(4) 3/4" DIA. SIMPSON

PAB6 ANCHOR BOLTS

(TYP.) (8" EMBEDMENT)

COLUMN BASEPLATE

- SEE SCHEDULE

HSS-COLUMN &

W-COLUMN, SEE PLAN

BP1 16" 16" 1"

(0'-0")

F.F.E.

SEE PLAN

T.O. FOOTING/SLAB

B

H

2" 2"

2"

2"

BP1

(6) 1" DIA. SIMPSON

PAB8H ANCHOR BOLTS

(TYP.) (30" EMBEDMENT)

COLUMN BASEPLATE

- SEE SCHEDULE

HSS-COLUMN &

W-COLUMN, SEE PLAN

BP2 BP3

SCALE: 3/4" = 1'-0"

TYPICAL SLAB-ON-GRADE

1

SCALE: 3/4" = 1'-0"

TYPICAL CONTROL JOINT

2

SCALE: 3/4" = 1'-0"

TYPICAL CONSTRUCTION JOINT

3

SCALE: 3/4" = 1'-0"

SECTION - ELEVATOR PIT

6

SCALE: 3/4" = 1'-0"

SECTION - ELEVATOR PIT

7

NOTE: 3 BOLT ROWS TO

BE IN SAME DIRECTION

AS BRACE FRAME.

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mo

n law

, statu

tory a

nd oth

er reserved

rights inclu

ding the

copyright the

reto.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

FO

UN

DA

TIO

N

DE

TA

ILS

HMH

HMH

HMH

S3.0

Page 9: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

6"

FTG.

1'-0

"

3'-0"

8" CMU

(3) #5 BARS LONGITUDINAL

TOP AND BOTTOM

4" SLAB-ON-GRADE

(TYP.)

TYPICAL SLAB-ON-GRADE

SEE DETAIL FOR REINF.

T.O.C.

F.F.E.

#5 NOSING BAR AT

EDGE (TYP.)

(2) #5 CONT. (TYP.)

1'-4

"

1'-0"

2 3

/4

"

CL

R.

OPTIONAL:

NOTCHED SLAB MAY BE PLACED IN

SEPARATE POURS AT CONTRACTOR'S

OPTION. IF CHOSEN, SCARIFY TOP OF

INITIAL FOOTING LUG, AND APPLY

BONDING AGENT TO EXPOSED FACE

PRIOR TO SLAB PLACEMENT.

EXTERIOR LIGHT-GUAGE STUD

FRAMING. FOR SHEATHING AND

VENEER INFO - SEE ARCH.

BRICK VENEER. SEE ARCH.

REINFORCING NOTES:

1. SEE GENERAL NOTES FOR ALL MATERIAL SPECIFICATIONS.

2. MASONRY SHALL BE LAID IN RUNNING BOND UNLESS NOTED OTHERWISE.

3. LAP SPLICES SHALL BE A MINIMUM OF 48 BAR DIAMETERS, U.N.O.

4. PROVIDE DUR-O-WALL (OR EQUAL) LADDER OR TRUSS TYPE HORIZONTAL

JOINT REINFORCEMENT AT EACH SECOND COURSE IN RUNNING BOND, AND

AT EACH COURSE IN STACKED BOND, UNLESS NOTED OTHERWISE.

DISCONTINUE HORIZONTAL JOINT REINFORCEMENT AT WALL CONTROL JOINTS.

5. MASONRY BOND BEAMS REINFORCED WITH (2)-#5 BARS ARE TO BE PROVIDED

EVERY 4-0" OF VERTICAL WALL, AT TOPS OF ALL MASONRY WALLS, AND WHERE

SHOWN ON DRAWINGS. FIRST BOND BEAM MAY BE PLACED AT TOP OF DOOR

OPENINGS, 8'-0" MAX. AT BOND BEAM CORNERS AND TEE JOINTS, PROVIDE BENT

BARS TO MATCH QUANTITY AND BAR SIZE IN THE BOND BEAM. REINFORCING LAP

SPLICES W/IN BOND BEAMS SHALL BE 48 BAR DIAMETERS OR A MINIMUM OF 2'-0",

WHICHEVER IS GREATER.

6. ALL MASONRY CELLS ARE TO BE GROUTED SOLID UNLESS NOTED OTHERWISE.

7. SEE PLANS AND DETAILS FOR ADDITIONAL REINFORCING REQUIREMENTS AT SUPPORTS,

TERMINATIONS, WALL INTERSECTIONS, AND MASONRY SHEAR WALL CHORDS.

CMU WALL REINFORCING SCHEDULE

APPLICATION / MARK BLOCK SIZE REINFORCING

TYP. SHAFT WALLS

TYP. SHAFT WALLS

8"

12"

#6 @ 40oc.

(2) #6 @ 40oc.

NOTES

-

-

TYPICAL

12" CMU

TYPICAL

8" CMU

GROUT SOLID AT ALL

REINFORCED CELLS

U.N.O. (TYP.)

SCALE: 3/4" = 1'-0"

TYPICAL MASONRY REINFORCING SCHEDULE

2

NOTES:

1. CMU LINTELS ARE PERMITTED ON AT EXTERIOR WALLS, AND TOP FLOOR

INTERIOR WALLS ONLY - ALL LOWER LOAD BEARING WALLS ARE TO USE

STEEL LINTELS AS DETAILED.

2. LINTEL DESIGN ASSUMES ARCHING ACTION OF BLOCK. NO WALL PENETRATIONS

ARE PERMITTED WITHIN SPAN/2 OR 24", (WHICH EVER IS GREATER), MEASURED

FROM TOP OF LINTEL. SHOULD PENETRATIONS BE REQUIRED WITHIN THIS AREA,

A STEEL LINTEL BEAM IS TO BE SUBSTITUTED PER THE PROVIDED DETAILS.

3. CMU LINTEL BEAMS ARE TO BEAR 8" (MIN.) ON EITHER SIDE OF OPENING.

HORIZONTAL REINFORCING IS TO BE CONTINUOUS OVER THE FULL SPAN + BEARING.

4. SEE DETAILS FOR TYPICAL JAMB REINFORCING.

5. REFER TO GENERAL REINGFORCING NOTES FOR ADDT'L. WALL CONSTRUCTION DETAILS.

CMU LINTEL SCHEDULE

MAX. OPENING BLOCK SIZE REINFORCING

8" (2)-#5 CONT.

TYPICAL CMU LINTEL

LIN

TE

L D

EP

TH

SE

E S

CH

ED

.

SEE

SCHED.

GROUT SOLID OVER FULL

LINTEL SPAN + BEARING

TY

P. W

AL

L

AB

OV

E

4'-0"

_<

LINTEL DEPTH

8"

_

REINFORCING

SEE SCHEDULE.

8" (2)-#5 CONT.6'-4"

_<

16"

_

TYPICAL WALL REINFORCING

AS REQ'D.

SCALE: 3/4" = 1'-0"

MASONRY LINTEL SCHEDULE

1

8"

(N

OM

.)

(4) CELLS

(4)-#6

GROUT SOLID - ALL CELLS. (TYP.)

GROUT SOLID - ALL CELLS. (TYP.)

(4) CELLS

(8)-#6

(2)-#6 @ 40"oc

BEYOND

12

"

(N

OM

.)

*INSIDE CORNERS SIMILAR

(3) CELLS

(3)-#6 BARS

(2

) C

EL

LS

(2

)-#

6 B

AR

S

(5) TOTAL BARS AT ALL CORNERS

(5) CELLS

(5)-#6 BARS

(2

) C

EL

LS

(2

)-#

6 B

AR

S

REINFORCING

AT INTERSECTION

(7) TOTAL BARS AT ALL CORNERS

REINFORCING

AT CORNER*

GROUT SOLID AT REINF. (TYP.)

SCALE: 3/4" = 1'-0"

ADDITIONAL REINFORCING AT CORNERS AND INTERSECTIONS

3

SCALE: 3/4" = 1'-0"

ADDITIONAL REINFORCING AT SHEARWALL CHORDS

4

MSW-2 - 8" CMU

MSW-1 - 12" CMU

(1)-#6 @ 40"oc

BEYOND

NOTE: AT 12" CMU - 2 BARS PER CELL

2'-6"

T

2T

ORNAMENTAL STAIRS

BY OTHERS. SEE ARCH.

1'-0"

(2) #5 CONT REBAR

#4 @ 24" O.C.

MIN

3

"

CL

R

CONC SLAB, SEE TYP

SLAB ON GRADE DETAIL

T.O. SLAB

SEE PLAN

SCALE: 3/4" = 1'-0"

THICKENED SLAB AT STAIR (TYP.)

5

(1) #4 EDGE BAR,

TYP

(1) #4 EDGE BAR,

TYP

#3 HOOKS @ 18"

O.C., TYP

(-3'-10")

T.O. FOOTING

(0'-0")

F.F.E.

SE

E A

RC

H

SLOPE-SEE ARCH

NOTE:

SEE ARCHITECTURALS FOR

SLOPE REQUIREMENTS OF 4"

SLAB ON GRADE AND TOP OF

PATIO EDGE ELEVATION.

SCALE: 3/4" = 1'-0"

TYPICAL EXTERIOR CMU PORCH WALL

6

#4 VERT. @ 24" O.C.

3"

#5 BARS TRANSVERSE @

18" O.C. TOP AND BOTTOM

3"

/////////////////// /////////////////////// ///////////////////

4" CONC. SLAB, REF

PLANS FOR DETAILS

LGS STUD WALL.

SEE PLAN.

BASE OF WALL TRACK. SEE

PLAN. ATTACH TO STUD w/ (2)

#10-16 SDS AND TO

CONCRETE w/ (2) PAFs AT

EACH STUD

1'-0"VAPOR BARRIER

1'-0

"

SCALE: 3/4" = 1'-0"

TYPICAL INTERIOR MEZZANINE WALL THICKENED SLAB

7

(2) #5 BARS

3"

6

"

M

I

N

8"

CONC. SLAB, SEE TYP

SLAB ON GRADE DETAIL

1/4" ISOLATION JOINT

#4 REBAR @ 12" O.C.

EACH WAY

#4 EDGE BAR, TYP

T.O. SLAB

SEE PLAN

T.O. SLAB

SEE PLAN

SCALE: 3/4" = 1'-0"

FOUNDATION SECTION AT CONCRETE STAIR

8

1/4" ISOLATION JOINT

#4 EDGE BAR, TYP

8"

4" SLAB-ON-GRADE, (TYP.)

SLOPE-SEE ARCH

SCALE: 3/4" = 1'-0"

TYP. INTERIOR WALL FOOTING TO PORCH SLAB TRANSITION

9

BRICK ROWLOCK COURSE.

SEE ARCH.

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

FO

UN

DA

TIO

N

DE

TA

ILS

HMH

HMH

HMH

S3.1

Page 10: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

NOTES:

1. ELEVATED SLAB DESIGN ASSUMES DECKING IS INSTALLED IN

TYPICAL 3-SPAN CONFIGURATION. GC IS TO COORDINATE

INSTALLATION LAYOUT AS REQ'D.

2. ELEVATED SLAB IS DESIGNED AS COMPOSITE. SEE DETAIL 2/S4.0

FOR TYPICAL SHEAR STUD DETAIL AND ATTACHMENT.

4"

2VLI22 COMPOSITE FLOOR DECK

(TYP.) w/ HILTI X-ENP19 PAFs IN 36/4

PATTERN TO SUPPORTS. 1-1/2" TOP

ARC SEAM WELD SIDELAP

CONNECTIONS AT 24" O.C.

4" NW CONCRETE SLAB (TYP.)

SCALE: 3/4" = 1'-0"

TYPICAL ELEVATED SLAB

1

36/4 PATTERN

6x6-W1.4xW1.4 W.W.F.

1.5PLB22 ROOF DECK (TYP.).

FASTEN TO SUPPORTS IN 36/4

PATTERN w/ #12 TEK FASTENERS

& PUNCHLOK II SIDELAP

CONNECTIONS @ 24" O.C.

NOTES:

1. ELEVATED SLAB DESIGN ASSUMES DECKING IS INSTALLED IN

TYPICAL 3-SPAN CONFIGURATION. GC IS TO COORDINATE

INSTALLATION LAYOUT AS REQ'D.

1 1

/2

"

36/4 PATTERN

SCALE: 3/4" = 1'-0"

TYPICAL ROOF DECK

3

TYP

CANTILEVERED END

W-BEAM - SEE PLAN

SHEAR CONN. AS

REQ'D. (TYP.)

3/8"

CL

5'-0"

6'-0

"

1/4"

TYP

1/4"

TYP

3

8

" STIFFENER PLATE

3/8"

TYP

3/8"

TYP

SCALE: 3/4" = 1'-0"

TYP. KNEE BRACE CONNECTION

4

HSS 6x6x1/4 KNEE BRACE

10" MIN.

1

2

" THICK GUSSET PLATE

1

2

" THICK GUSSET PLATE

3/8" STIFFENER PLATE.

(REQUIRED FOR WIDE

FLANGE COLUMNS)

HSS COLUMN - SEE PLAN

*OPPOSITE HAND SIMILAR

WHERE APPLICABLE.

W-BEAM - SEE PLAN

THRU-PLATE SHEAR CONN. AS

REQ'D. (TYP.)

SCALE: 3/4" = 1'-0"

TYPICAL BEAM-COLUMN MOMENT CONNECTION-MC

6

CP

TYP

CP

TYP

SCALE: 3/4" = 1'-0"

5

MOMENT CONNECTION (MC)

SECTION - TYPICAL BEAM-GIRDER

W-BEAM - SEE PLAN

3/4" THICK A36

CAP PLATE

A

HSS COLUMN, SEE

PLAN.

2" 1'-0" 2"

2"

4"

2"

(4) 3/4" DIA.

A325 BOLTS

SECTION A

W-BEAM - SEE PLAN

T.O. STEEL

VARIES

TYPICAL COMPOSITE SLAB,

SEE DETAIL 1/S4.0

GUARDRAIL BY OTHERS. SEE

ARCHITECTURALS FOR SIZES

AND LOCATIONS.

SHEAR CONNECTION

AS REQUIRED

W-BEAM GIRDER - SEE PLAN

L4x4x5/16 CONT. EDGE

ANGLE (TYP.)

SCALE: 3/4" = 1'-0"

TYPICAL SLAB EDGE

7

1/4"

TYP

2 @ 12

1/4" BEAM WEB STIFFENER

EACH SIDE OF WEB. 8" HEIGHT.

8"

W-BEAM - SEE PLAN.

8" CONT. BOND BEAM COURSE

W/ (2) #5 AT JOIST BEARING

ELEVATION (TYP.)

8" OR 12" CMU BEARING

WALL - SEE PLAN

T.O. STEEL

VARIES-SEE PLAN

TYPICAL WALL REINF.

BEYOND - SEE DETAIL

2"

L4x4x5/16 CONT. ALONG ENTIRE LENGTH

OF CMU WALL (ORIENTED AS SHOWN) W/

1/2"Ø HILTI HUS-EZ ANCHORS (4 1/4" MIN.

EMBED) @ 8" O.C. & 1/2" HEADED STUDS x

4"L & 8" O.C. ANCHORS ARE TO BE

CENTERED IN GROUTED CELLS - STAGGER

HEADED STUDS AS REQ'D. (TYP. EA. SIDE).

EMBED

GR

OU

T S

OL

ID

(3

)-C

OU

RS

ES

(C

ON

T.)

8" (M

IN

.)

8" (M

IN

.)

4 1/4" (MIN.)

3/8" MIN. THICK DOUBLE ANGLE CONNECTION

TO W-BEAM. 4-1/2" MIN. LEG SIZE TO CMU.

(4) 5/8" DIA. HILTI KWIK HUS-EZ ANCHORS.

5" MIN. EMBEDMENT.

5" (M

IN

.)

6" (MIN.)

5" MIN. EMBED

FACE OF BEAM CONNECTION

NOTE:

DO NOT PLACE ANCHORS w/IN

1.1/4" OF CMU HEAD JOINT.

MAINTAIN MINIMUM EDGE

DISTANCES TO TOP/ BOTTOM

OF SOLID GROUTED CMU

BOND BEAM AS SHOWN.

SCALE: 3/4" = 1'-0"

SINGLE W-BEAM BEARING AT SHEARWALL

8

4-1/2" MIN.

STEEL BEAM, SEE PLAN

6-1/2" x 3/8" x 6-1/2" BEARING

PLATE w/ (2) 1/2" x 5" HIGH

STRENGTH ANCHORS

COPE BOTTOM FLANGE AS

NEEDED FOR KEEPER PLATES

WHEN SLIP JOINT IS REQUIRED

PARALLEL

BEARING

NOTES:

1. GROUT ALL HATCHED AREAS IN ADDITION TO VERTICAL REINFORCED CELLS.

2. PROVIDE SLIP BEARING WITH 2" x 3/16" x 4" KEEPER PLATE AT MASONRY OPENINGS GREATER THAN 10'-0". WELD KEEPER PLATES TO

BEARING PLATE, DO NOT WELD KEEPER TO BEAM FLANGE NOR BEAM FLANGE TO BEARING. GREASE BOTTOM OF BEAM FOR SLIPPAGE.

KEEPER PLATES WHEN

REQUIRED, SEE NOTE 2

STEEL BEAM, SEE PLAN, STOP

END OF BEAM 2" FROM OPPOSITE

SIDE OF PERPENDICULAR CMU

6-1/2" x 3/8" x 1'-2" BEARING

PLATE w/ (2) 1/2" x 5" HIGH

STRENGTH ANCHORS

PERPENDICULAR

BEARING

2' G

RO

UT

KEEPER PLATES WHEN

REQUIRED, SEE NOTE 2

2'-0" BOND BEAM 2'-0" BOND BEAM

VERT WALL BARS, (2) EACH

CELL, (1) EACH FACE

3/16"

1/4"

SCALE 3/4" = 1'-0"

TYP. STEEL BEAM BEARING ON CMU WALL DETAIL (HOIST BEAM)

9

4"

4"

7 1/4" 4 3/4" 7 1/4" 4 3/4" 7 1/4"

4 3/4"

3/4"

MIN

3/4"

MIN

1"

MIN

1'-0"

DECK RIBS

B.O. DECK

RIB

B.O. DECK

RIB

FL

AN

GE

WID

TH

1"

MIN

3/4"

MIN

3/4"

MIN

EQ

EQ

3"

MIN

COMPOSITE DECK

3/4"Øx3"L HEADED

STUD (TYP.)

BEAM FLANGE

TYPICAL ORIENTATION

OF 2 STUDS PER RIN

TYPICAL ORIENTATION

OF 1 STUD PER RIN

SECTION

PLAN

SCALE: 1-1/2" = 1'-0"

TYPICAL COMPOSITE SLAB STUD PLACEMENT

2

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

FR

AM

IN

G

DE

TA

ILS

HMH

HMH

HMH

S4.0

Page 11: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

/ / / / / / / /

CL

T.O.C.

SEE PLAN

SCALE: 3/4" = 1'-0"

TYPICAL SLAB AT DECK CHANGE

11

STEEL BEAM. SEE PLAN.

CONT. 16GA GIRDER FLASH

WHERE REQUIRED BY

SUPPLIER

CELL CLOSURE

COMPOSITE DECK, REF PLAN

FOR REQUIREMENTS

SEE ARCH.

C

L

W-BEAM - SEE PLAN.

TYPICAL COMPOSITE SLAB

SEE DETAILS 1/S3.0

L4x4x5/16" CONT. EDGE

ANGLE (TYP.)

L3x3x1/4 DIAGONAL BRACE AS

SHOWN @ 4'-0" MAX. O.C. (TYPICAL)

W-BEAM -

SEE PLAN.

1/4"

TYP

LGS FRAMING BY

SUBCONTRACTOR. PROVIDE 3/4"

DEFL. GAP @ CONNECTION TO

STEEL (TYP.)

C

L

SCALE: 3/4" = 1'-0"

TYPICAL EXTERIOR SLAB EDGE

12

0.6C26 METAL DECK (TYP.)

FASTEN TO SUPPORTS IN 36/4

PATTERN w/ #12 TEK FASTENERS

& #10 TEK FASTENER SIDELAP

CONNECTIONS @ 24" O.C.

NOTES:

1. ELEVATED SLAB DESIGN ASSUMES DECKING IS INSTALLED IN

TYPICAL 3-SPAN CONFIGURATION. GC IS TO COORDINATE

INSTALLATION LAYOUT AS REQ'D.

1 5

/8

"

36/4 PATTERN

SCALE: 3/4" = 1'-0"

TYPICAL MECHANICAL MEZZANINE DECK

13

NONSTRUCTURAL TOPPING SLAB

CL CL

T.O.S.

33'-8"

T.O.C.

30'-3"

PRE-FABRICTED LGS TRUSS BY

MANUFACTURER.

1.5 ROOF DECK - SEE PLAN.

ROOFING - SEE ARCH.ELEVATED TRUSS BEARING SEAT, TO

BEAR AT ROOF ELEVATION AS SHOWN.

SEE PLAN FOR T.O.S.

HOLDOWN CONNECTION BY TRUSS

MANUFACTURER, TO MATCH

ULTIMATE/ PROPRIETARY CHORD

PROFILE, TYP. SEE WIND LOAD

INFORMATION ON PLAN, TYP.

W-BEAM

SEE PLAN.

1/4" GUSSET @ 4'-0"oc

(TYP. AT TRUSS BEARING)

3/8" CONTINUOUS PLATE - MATCH

PRIMARY STEEL T.O.S. ELEVATION.

7 1/2"

W-BEAM - SEE PLAN.

REF. 12/S4.1 FOR TYPICAL KICKER

BRACING AT PERIMETER W-BEAM.

ELEVATED SLAB - SEE PLAN.

GUARDRAIL ASSEMBLY BY OTHERS - SEE ARCH.

GUARDRAIL TO ANCHOR DIRECTLY TO SLAB.

SEE

ARCH

LGS WALL BELOW - SEE PLAN.

CL CL

T.O.S.

33'-8"

T.O.C.

30'-3"

LGS INFILL TO ACCOMMODATE

BALCONY PROFILE

EXTENT OF TRUSS PROFILE BEYOND.

W-BEAM

SEE PLAN.

ELEVATED SLAB.

SEE PLAN.

LGS WALL BELOW - SEE PLAN.

SCALE: 3/4" = 1'-0"

SECTION - ROOF BALCONY

16

HSS6x6x1/4

3'-8"

C6x8.2 CHANNEL HANGER

A

A

ROOF PLANE BEYOND

C6x8.2 HANGER (LGS INFILL BEYOND)

GUARDRAIL ASSEMBLY BY OTHERS - SEE ARCH.

GUARDRAIL TO ANCHOR DIRECTLY TO SLAB.

SECTION A-A

(2)-L3X3X1/4" KICKER w/

1/4" (MIN.) GUSSET

3/8" STIFFENER PLATE CENTERED ABOVE

HANGER CONNECTION, (EA. SIDE)

CL

4'-0"

4'-0

"

1/4"

TYP

1/4"

TYP

3

8

" STIFFENER PLATE

3/8"

TYP

3/8"

TYP

SCALE: 3/4" = 1'-0"

TYP. HIGH ROOF KNEE BRACE CONNECTION

14

HSS 6x6x1/4 KNEE BRACE

10" MIN.

1

2

" THICK GUSSET PLATE

1

2

" THICK GUSSET PLATE

4"

4"

10

" M

IN

.

SCALE: 3/4" = 1'-0"

TYPICAL TRUSS BEARING

15

W-BEAM

SEE PLAN.

W-BEAM - SEE PLAN

T.O. STEEL

SEE PLAN

TYPICAL COMPOSITE SLAB,

SEE DETAIL 1/S4.0

W-BEAM GIRDER - SEE PLAN

WT-SHIM AS REQUIRED TO

ALLOW BEARING ON

GIRDER BELOW

W-BEAM - SEE PLAN

T.O. STEEL

SEE PLAN

SCALE: 3/4" = 1'-0"

SECTION - TYPICAL BEAM BEARING ON GIRDER

17

3/8" WEB STIFFENER EACH SIDE

OF GIRDER WEB, CENTERED

BELOW EACH SEATED BEAM

BEARING ABOVE

3/8" WEB STIFFENER EACH SIDE

OF EACH W24xXX, CENTERED

ABOVE GIRDER BEAM WEB BELOW

W-BEAM

SEE PLAN.

VERT WALL BARS TO MATCH TYP. WALL

REINF (2) EACH CELL, (1) EACH FACE MIN.

STEEL BEAM & PLATE,

SEE PLAN AND SECTION

3/8"x7"x7"

BEARING PLATE

CONT. 'KNOCK-OUT' BLOCK BOND BEAM

w/ (2) #5 CONT. FILL w/ GROUT CONT.

ABOVE STEEL BEAM

3/4"dia x 4'-0" DBA ANCHOR,

SPACING & ALIGNMENT TO

MATCH WALL VERT REBAR,

WELD TO BEAM

GR

OU

T S

OL

ID

24

" A

BO

VE

L

IN

TE

L

VERT WALL BARS, SEE

SCHEDULE FOR SIZE,

SPACING, AND LOCATIONS

BOND BEAM

w/ (2) #5

1/2"

2'-0" MIN

1/4" 5"

1/4" 5"

STEEL BEAM BEARING

7"

TOP VIEW - BEARING

3/4"

TYP

3/8" THICK BEARING PLATE w/

(2) 3/4" DIA. x 48" DBA ANCHOR

1/4" FINISH PLATE

EXTEND ONLY TO

EDGE OF OPENING

SECTION VIEW

1/4" 2@8

TYP

MASONRY SOAPS

7"

SCALE: 1/2" = 1'-0"

TYP. BEAM BEARING AT CMU WALL CORNERS

10

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mo

n law

, statu

tory a

nd oth

er reserved

rights inclu

ding the

copyright the

reto.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

FR

AM

IN

G

DE

TA

ILS

HMH

HMH

HMH

S4.1

Page 12: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

T.O. STEEL

SEE PLAN

LGS WALL BELOW

- SEE PLAN.

1200S162-54 JOISTS @ 24"

O.C. MAX.

0.6C26 METAL DECK w/ NON

STRUCTURAL TOPPING SLAB.

SEE DETAIL 13/S4.1.

STEEL BEAM FRAMING -

SEE PLAN.

TYPICAL COMPOSITE SLAB,

SEE DETAIL 1/S4.0

SCALE: 3/4" = 1'-0"

TYP. RAISED BAR FLOOR

18

STIFFCLIP AL600 w/ (4)

#12-14 SDS TO JOIST AND

(2) PAFs TO CONCRETE @

4'-0" O.C. MAX.

ROOFING INSULATION AND

MEMBRANE - SEE ARCH

WALKABLE ROOFING FINISH

- SEE ARCH

STEEL BEAM FRAMING -

SEE PLAN.

CL

6" HSS COLUMN. SEE PLAN.

SCALE: 3/4" = 1'-0"

TYP. HIGH ROOF 6" TO 8" COLUMN CONNECTION

19

8" HSS COLUMN. SEE PLAN.

STEEL BEAM. SEE PLAN.

SEE PLAN

T.O. STEEL

1/4"

TYP

3/8" MIN. THICKNESS CAP PLATE

CJP - CAP PLATE

TO COLUMN

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mo

n law

, statu

tory a

nd oth

er reserved

rights inclu

ding the

copyright the

reto.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

FR

AM

IN

G

DE

TA

ILS

HMH

HMH

HMH

S4.2

Page 13: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

JA

MB

H

EIG

HT

(S

EE

S

CH

ED

UL

E)

JAMB TO HEAD CONNECTION,

SEE SCHEDULE

JAMB TO HEADER CONNECTION

USING STIFFCLIP AL BY TSN,

SEE SCHEDULE

LGS BOX HEADER, SEE

SCHEDULE

WIN

DO

W H

EIG

HT

(M

AX

.)

SE

E T

AB

LE

WIDTH (MAX.)

SEE TABLE

BOTTOM TRACK, SEE TYP.

WALL SECTION

JAMB TO BASE CONNECTION,

SEE SCHEDULE

TOP TRACK, SEE TYP.

WALL SECTIONS

JAMB, SEE SCHEDULE

CRIPPLE STUDS TO MATCH

ADJACENT WALL STUDS

SCALE: 3/4" = 1'-0"

OPENING FRAMING ELEVATION - WINDOWS

---

SIL

L H

EIG

HT

(M

AX

.)

SE

E T

AB

LE

JAMB TO SILL CONNECTION,

SEE SCHEDULE

LGS SILL, SEE SCHEDULE

JA

MB

H

EIG

HT

(S

EE

S

CH

ED

UL

E)

JAMB TO HEAD CONNECTION,

SEE SCHEDULE

JAMB TO HEADER CONNECTION

USING STIFFCLIP AL BY TSN,

SEE SCHEDULE

LGS BOX HEADER, SEE

SCHEDULE

HE

IG

HT

(M

AX

.)

SE

E T

AB

LE

WIDTH (MAX.)

SEE TABLE

BOTTOM TRACK, SEE TYP.

WALL SECTION

JAMB TO BASE CONNECTION,

SEE SCHEDULE

TOP TRACK, SEE TYP.

WALL SECTIONS

JAMB, SEE SCHEDULE

CRIPPLE STUDS TO MATCH

ADJACENT WALL STUDS

STEEL BEAM AND

CONCRETE SLAB

SCALE: 3/4" = 1'-0"

OPENING FRAMING ELEVATION - DOORS

---

STEEL BEAM AND

CONCRETE SLAB

WINDOW SCHEDULE

MARK

JAMB

HEIGHT

(MAX.)

WINDOW

WIDTH

(MAX.)

WINDOW

HEIGHT

(MAX.)

SILL

HEIGHT

(MAX.)

JAMB SECTION HEADER SECTION SILL SECTION

JAMB SECTION JAMB TO BASE JAMB TO HEAD HEADER SECTION HEADER TO JAMB SILL SECTION SILL TO JAMB

H4A 16'-4" 6'-8" 2'-4" 5'-0"

(2) 600S350-68 [50] BTB +

(1) 600T200-68 [50]

STIFFCLIP CL362-68 BY TSN,

(6) #12-14 SDS TO STUD, (1)

1/2" F1554 GR. 36 ROD w/

SET-3G (4" EMBED) TO

CONCRETE w/ 4.25" EDGE

DISTANCE

VERTICLIP SL600 BY TSN, (2)

#12-14 SDS TO STUD, (2) PAF

TO STEEL BEAM

BOX: (2) 600S162-43 [33] +

(2) 600T125-43 [33]

(2) STIFFCLIP AL600 BY TSN,

(2) #12-14 SDS EA. LEG

600T125-54 [50]

STIFFCLIP AL600 BY TSN, (2)

#12-14 SDS TO STUD, (2)

#12-14 SDS TO JAMB

DOOR SCHEDULE

MARK

JAMB

HEIGHT

(MAX.)

DOOR

WIDTH

(MAX.)

DOOR

HEIGHT

(MAX.)

JAMB SECTION HEADER SECTION

JAMB SECTION JAMB TO BASE JAMB TO HEAD HEADER SECTION HEADER TO JAMB

H1A 15'-4" 3'-8" 8'-4"

(1) 600S350-97 [50]

STIFFCLIP CL362-68 BY TSN, (6)

#12-14 SDS TO STUD, (1) 1/2"

F1554 GR. 36 ROD w/ SET-3G (4"

EMBED) TO CONCRETE w/ 4.25"

EDGE DISTANCE

VERTICLIP SL600 BY TSN, (3)

#12-14 SDS TO STUD, (2) PAF

TO STEEL BEAM

BOX: (2) 600S162-54 [50] +

(2) 600T125-54 [50]

(2) STIFFCLIP AL600 BY

TSN w/ (4) #12-14 SDS EA.

LEG

H1B 16'-6" 3'-8" 8'-4"

(1) 600S350-97 [50] +

(1) 600T200-97 [50]

STIFFCLIP CL362-68 BY TSN, (2)

#12-14 SDS TO STUD, (1) 1/2"

F1554 GR. 36 ROD w/ SET-3G (2.75"

EMBED) TO CONCRETE w/ 4.25"

EDGE DISTANCE

VERTICLIP SL600 BY TSN, (3)

#12-14 SDS TO STUD, (2) PAF

TO STEEL BEAM

BOX: (2) 600S162-43 [33] +

(2) 600T125-43 [33]

(2) STIFFCLIP AL600 BY

TSN w/ (4) #12-14 SDS EA.

LEG

H2 15'-4" 13'-0" 8'-4"

(2) 600S350-97 [50] +

(2) 600T200-97 [50]

STIFFCLIP CL362-68 BY TSN, (6)

#12-14 SDS TO STUD, (1) 1/2"

F1554 GR. 36 ROD w/ SET-3G (4"

EMBED) TO CONCRETE w/ 4.25"

EDGE DISTANCE

(2) VERTICLIP SL600 BY TSN, (3)

#12-14 SDS TO STUD, (2) PAF

TO STEEL BEAM

BOX: (2) 362S162-97 [50] +

(2) 600T200-97 [50]

(2) STIFFCLIP AL600 BY

TSN, (4) #12-14 SDS EA.

LEG

H3 16'-4" 13'-0" 9'-0"

(2) 600S350-97 [50] +

(2) 600T200-97 [50]

STIFFCLIP CL362-68 BY TSN, (6)

#12-14 SDS TO STUD, (1) 1/2"

F1554 GR. 36 ROD w/ SET-3G (2.75"

EMBED) TO CONCRETE w/ 4.25"

EDGE DISTANCE

VERTICLIP SL600 BY TSN, (3)

#12-14 SDS TO STUD, (3) PAF

TO STEEL BEAM

BOX: (2) 600S162-54 [50] +

(2) 600T200-97 [50]

(2) STIFFCLIP AL600 BY

TSN, (4) #12-14 SDS EA.

LEG

H5 13'-0" 13'-0" 7'-4"

(2) 600S350-68 [50] +

(1) 600T200-68 [50]

STIFFCLIP CL362-68 BY TSN, (6)

#12-14 SDS TO STUD, (1) 1/2"

F1554 GR. 36 ROD w/ SET-3G (2.75"

EMBED) TO CONCRETE w/ 4.25"

EDGE DISTANCE

VERTICLIP SL600 BY TSN, (3)

#12-14 SDS TO STUD, (3) PAF

TO STEEL BEAM

BOX: (2) 600S162-54 [50] +

(2) 600T200-97 [50]

(2) STIFFCLIP AL600 BY

TSN, (4) #12-14 SDS EA.

LEG

H6 13'-0" 6'-9" 7'-4"

600S350-97 [50]

STIFFCLIP CL362-68 BY TSN, (6)

#12-14 SDS TO STUD, (1) 1/2"

F1554 GR. 36 ROD w/ SET-3G (2.75"

EMBED) TO CONCRETE w/ 4.25"

EDGE DISTANCE

VERTICLIP SL600 BY TSN, (3)

#12-14 SDS TO STUD, (3) PAF

TO STEEL BEAM

BOX: (2) 600S162-43 [33] +

(2) 600T125-43 [33]

(2) STIFFCLIP AL600 BY

TSN, (4) #12-14 SDS EA.

LEG

H7 13'-0" 3'-4" 7'-4"

600S300-97 [50]

STIFFCLIP CL362-68 BY TSN, (6)

#12-14 SDS TO STUD, (1) 1/2"

F1554 GR. 36 ROD w/ SET-3G (2.75"

EMBED) TO CONCRETE w/ 4.25"

EDGE DISTANCE

VERTICLIP SL600 BY TSN, (3)

#12-14 SDS TO STUD, (3) PAF

TO STEEL BEAM

BOX: (2) 600S162-43 [33] +

(2) 600T125-43 [33]

(2) STIFFCLIP AL600 BY

TSN, (4) #12-14 SDS EA.

LEG

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

LG

S O

PE

NIN

G

ELE

VA

TIO

NS

HMH

HMH

HMH

S5.0

Page 14: S0€¦ · aci 318-14 building code requirements for structural concrete and commentary. 2018 north carolina state building code. design codes: and general notes such as 'dimensions

JA

MB

H

EIG

HT

(S

EE

S

CH

ED

UL

E)

JAMB TO HEAD CONNECTION,

SEE SCHEDULE

JAMB TO HEADER CONNECTION.

SEE SCHEDULE.

LGS BOX HEADER, SEE

SCHEDULE

HE

IG

HT

(M

AX

.)

SE

E T

AB

LE

WIDTH (MAX.)

SEE TABLE

BOTTOM TRACK, SEE TYP.

WALL SECTION

JAMB TO BASE CONNECTION,

SEE SCHEDULE

TOP TRACK, SEE TYP.

WALL SECTIONS

JAMB, SEE SCHEDULE

CRIPPLE STUDS TO MATCH

ADJACENT WALL STUDS

STRUCTURE ABOVE.

SEE PLAN.

SCALE: 3/4" = 1'-0"

OPENING FRAMING ELEVATION - MEZZANINE WALL DOORS

---

DOOR SCHEDULE

MARK

JAMB

HEIGHT

(MAX.)

DOOR

WIDTH

(MAX.)

DOOR

HEIGHT

(MAX.)

JAMB SECTION HEADER SECTION

JAMB SECTION JAMB TO BASE JAMB TO HEAD HEADER SECTION HEADER TO JAMB

H8 16'-8" 3'-4" 7'-2"

362S162-97 [50]

STIFFCLIP AL362 w/ (2) #12-14

SDS TO JAMB AND (2) 1/4"x1-1/4"

HILTI KWIK CON II+ (2" MIN.

SPACING)

VERTICLIP SL362 BY TSN w/ (2)

#12-14 SDS TO JAMB & (2) PAFs

TO STEEL BEAM OR (2) 1/4"x1-1/4"

HILTI KWIK CON II+ TO

CONCRETE (2" MIN. SPACING)

BOX: (2) 362S162-54 [50] +

(2) 362T125-54 [50]

(2) STIFFCLIP AL362 BY

TSN w/ (4) #12-14 SDS EA.

LEG

H9 16'-8" 3'-4" 7'-2"

(1) 362S300-97 [50] +

(1) 362T200-97 [50]

STIFFCLIP AL362 w/ (2) #12-14

SDS TO JAMB AND (2) 1/4"x1-1/4"

HILTI KWIK CON II+ (2" MIN.

SPACING)

VERTICLIP SL362 BY TSN w/ (2)

#12-14 SDS TO JAMB & (2) PAFs

TO STEEL BEAM OR (2) 1/4"x1-1/4"

HILTI KWIK CON II+ TO

CONCRETE (2" MIN. SPACING)

BOX: (2) 362S162-68 [50] +

(2) 362T125-68 [50]

(2) STIFFCLIP AL362 BY

TSN w/ (4) #12-14 SDS EA.

LEG

H10 16'-8" 3'-4" 7'-2"

(1) 600S300-54 [50]

STIFFCLIP AL600 w/ (2) #12-14

SDS TO JAMB AND (2) 1/4"x1-1/4"

HILTI KWIK CON II+ (2" MIN.

SPACING)

VERTICLIP SL600 BY TSN w/ (2)

#12-14 SDS TO JAMB & (2) PAFs

TO STEEL BEAM OR (2) 1/4"x1-1/4"

HILTI KWIK CON II+ TO

CONCRETE (2" MIN. SPACING)

BOX: (2) 362S162-54 [50] +

(2) 600T125-54 [50]

(2) STIFFCLIP AL600 BY

TSN w/ (4) #12-14 SDS EA.

LEG

H11 16'-8" 6'-4" 7'-2"

(1) 600S350-54 [50]

STIFFCLIP AL600 w/ (2) #12-14

SDS TO JAMB AND (2) 1/4"x1-1/4"

HILTI KWIK CON II+ (2" MIN.

SPACING)

VERTICLIP SL600 BY TSN w/ (2)

#12-14 SDS TO JAMB & (2) PAFs

TO STEEL BEAM OR (2) 1/4"x1-1/4"

HILTI KWIK CON II+ TO

CONCRETE (2" MIN. SPACING)

BOX: (2) 362S200-97 [50] +

(2) 600T125-97 [50]

STIFFCLIP HE(S)-68 BY

TSN w/ (4) #10-16 SDS

HORIZONTAL / (8) #10-16

SDS VERTICAL PATTERN

DESIGNED BY:

DRAWN BY:

APPROVED BY:

PROJECT #:

DATE:

No. Revision Date

Sheet

Ow

nership of Instrum

ents of S

ervice: A

ll reports, plans, specifications, com

puter files, field data, notes and instrum

ents prepared by the design professional as instrum

ents of service shall rem

ain the property of the design professional. A

ll com

mon

la

w, statuto

ry an

d o

the

r re

se

rved rig

hts in

clud

in

g th

e cop

yrig

ht thereto

.

Sheet T

itle

Project N

am

e

CLU

BH

OU

SE

MO

RE

HE

AD

C

IT

Y, N

OR

TH

C

AR

OLIN

A

MO

RE

HE

AD

C

IT

Y C

OU

NT

RY

C

LU

B

20-254

01/29/2021

LG

S O

PE

NIN

G

ELE

VA

TIO

NS

HMH

HMH

HMH

S5.1


Recommended