AND SYMBOLSLEGENDS,
ABBREVIATIONS,
S0.01
2/22/2012
1:2
1:1
4 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
0_01
AB
BR
EV.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
SIZEBAR
SIZEBAR
ALL CONCRETE STRENGTHS
#18#14#11#10#9#8#7#6#5#4#3
8866555044393424201612
115 86 72 65 58 51 45 32 26 21 16
- -726558514532262116
- -948576675942342821
#18#14#11#10#9#8#7#6#5#4#3
433327242219171512108
- -423834302623191512
- -322926232017141212
DRAWING LIST
CONNECTORS
CONCRETE SYMBOLS MISCELLANEOUS SYMBOLS
REINFORCING BAR DEVELOPMENT AND SPLICE LENGTH TABLESABBREVIATIONS
SIZEBAR
TABLE A
SIZEBAR NORMAL WEIGHT CONCRETE , f’c (psi)
3,000 4,000 5,000 6,000 8,000
END HOOK
OF SUPPORTJOINT OR FACECONSTRUCTION
dh
7,000
#18
#14
#11
#10
#9
#8
#7
#6
#5
#4
#3
(D) FINISHED BEND DIAMETERALL GRADES
(L ) FOR STANDARD END HOOKS ON GRADE 60 BARSMINIMUM TENSION EMBEDMENT LENGTHS,
OF SUPPORTJOINT OR FACECONSTRUCTION
24"
18 "
12"
10 "
9 "
6"
5
4 "
3 "
3"
2 "
D E J A
HOOKS90
#18#14#11#10 #9 #8 #7 #6 #5 #4 #3
50"37"22"20"18"16"14"12"10" 8" 6"
43"32"19"17"15"14"12"10" 9" 7" 6"
35"27"16"14"13"11"10" 8" 7" 7" 6"
33"25"15"14"12"10" 9" 8" 7" 7" 6"
39"29"17"15"14"12"11" 9" 8" 7" 6"
31"35"15"14"11"10" 9" 8" 7" 7" 6"
180 HOOKS
36"
27"
19"
17"
15"
11"
10"
8"
7"
6"
5"
28 "
21 "
14 "
13 "
11 "
8"
7"
6"
5"
4"
3"
41"
31"
24"
22"
19"
16"
14"
12"
10"
8"
6"
f’c = 6,000 PSI
180 DEGREE HOOK 90 DEGREE HOOK
DRAWING TITLE
AB ANCHOR BOLTACI AMERICAN CONCRETE INSTITUTEADDL ADDITIONALADJ ADJACENT
AGGR AGGREGATE
ALT ALTERNATEALUM ALUMINUM
APA AMERICAN PLYWOOD ASSOCIATIONAPPD APPROVEDAPPROX APPROXIMATE
ARCH ARCHITECTURAL; ARCHITECTASSY ASSEMBLYASTM AMERICAN SOCIETY FOR TESTING AND MATERIALSAWS AMERICAN WELDING SOCIETY
& AND
BAL BALANCEBD BOARD
BLDG BUILDINGBLK BLOCK; BLOCKINGBM BEAM
BOT BOTTOM
BRG BEARINGBRKT BRACKET
BTWN BETWEENBU BUILT-UP
C STANDARD CHANNEL
CC CENTER TO CENTERCG CENTER OF GRAVITYCIP CAST-IN-PLACECJ CONSTRUCTION JOINT
CL CENTERLINECLR CLEARANCE; CLEARCMU CONCRETE MASONRY UNITCOL COLUMNCOMP COMPRESSIONCONC CONCRETE
CONN CONNECTION; CONNECTCONST CONSTRUCTIONCONT CONTINUE; CONTINUOUSCONTR CONTRACTOR
CORR CORRUGATED
CTR CENTERCTSK COUNTERSINK; COUNTERSUNK
DBL DOUBLEDEG, DEGREE
DEPT DEPARTMENTDET DETAILDIA, ~ DIAMETERDIAG DIAGONALDIAPH DIAPHRAGMDICA DRILLED-IN CONCRETE ANCHORDIM DIMENSION
DWG DRAWINGDWL DOWEL
BRCG BRACING
BMU BRICK MASONRY UNIT
EA EACHEF EACH FACEEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRICALELEV ELEVATOR
ENGR ENGINEEREQ EQUAL; EARTHQUAKEEQUIP EQUIPMENTES EACH SIDEETC ET CETERAEW EACH WAYEXIST EXISTING
EXT EXTERIOREXTD EXTEND; EXTENDED
FD FLOOR DRAINFDN FOUNDATIONFF FAR FACE
FIN FINISHFL FLOOR; FLOOR LINEFLG FLANGEFOS FACE OF STUDFP FIREPROOF; FULL PENETRATION
FS FULL SIZE; FAR SIDEFT FOOT; FEETFTG FOOTING
GALV GALVANIZEDGB GRADE BEAM
GRND GROUND
HORIZ HORIZONTALHP HP SHAPES; HIGH POINTHS HIGH STRENGTH
HT HEIGHT
ID INSIDE DIAMETERIN INCHINCL INCLUDEINFO INFORMATION
JT JOINT
KO KNOCK-OUTKSI KIPS PER SQUARE INCH
L ANGLELAB LABORATORY
LF LINEAL FOOTLIN LINEAL; LINEAR
LLBB LONG LEGS BACK-TO-BACK
LP LOW POINTLSL LONG SLOTTED (HOLES)
LTWT LIGHTWEIGHTLVL LEVEL
LONGIT LONGITUDINAL
MAS MASONRYMATL MATERIALMAX MAXIMUMMB MACHINE BOLTMC MISCELLANEOUS CHANNELMECH MECHANICALMEMB MEMBRANE
MIN MINIMUM; MINUTEMISC MISCELLANEOUS
MO MASONRY OPENING
N NORTH
NF NEAR FACE
NIC NOT IN CONTRACTNS NEAR SIDENTS NOT TO SCALE
OC ON CENTEROD OUTSIDE DIAMETEROPNG OPENING
OVS OVERSIZED (HOLES)
PC PRECAST
PCP PRECAST CONCRETE PANEL
PERP PERPENDICULAR
PL PLATE
PLYWD PLYWOOD
PREFAB PREFABRICATEDPS PRESTRESSEDPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
RB RISER BARRCMD RECOMMENDREF REFERENCE
REQD REQUIREDREQT REQUIREMENT
S2S SURFACED TWO SIDES
SB SPACER BAR; SUPPORT BAR
SECT SECTION
SHT SHEET
SIM SIMILARSLBB SHORT LEGS BACK-TO-BACKSOG SLAB ON GRADESP SPIRAL
SPCG SPACINGSPECS SPECIFICATIONSSQ SQUARESSL SHORT SLOTTED (HOLES)STD STANDARDSTIFF STIFFENERSTIRR STIRRUPSTL STEELSTR STRAIGHTSTRUC STRUCTURAL
SC SLIP CRITICAL
SDQ SPECIAL DUCTILE QUALITY
SYM SYMMETRICAL
PEN PENETRATION
T&B TOP AND BOTTOMT&G TONGUE AND GROOVETEMP TEMPERATURE; TEMPORARY
TOC TOP OF CONCRETE; TOP OF CURBTOF TOP OF FOOTINGTOS TOP OF STEELTOW TOP OF WALL
TYP TYPICAL
UBC UNIFORM BUILDING CODE
UNO UNLESS NOTED OTHERWISEUT ULTRASONIC TEST
VG VERTICAL GRAIN
W/ WITHW/O WITHOUTWD WOOD
WH WEEP HOLE
WP WORK POINTWPJ WEAKENED PLANE JOINT
SUPT SUPPORT
LOC LOCATION, LOCATE
BSMT BASEMENT
c CAMBER
CANT CANTILEVER
COORD COORDINATE; COORDINATION
DISC DISCONTINUED; DISCONTINUOUSDL DEAD LOAD
EMBED EMBEDDED
INT INTERIOR
LL LIVE LOAD
LLH LONG LEGS HORIZONTALLLV LONG LEGS VERTICAL
NFPA NATIONAL FOREST PRODUCTS ASSOCIATION
OPP OPPOSITE (HAND)OPT OPTION; OPTIONAL
OWJ OPEN WEB JOIST
PCF POUNDS PER CUBIC FOOT
PT POST-TENSION
BF BRACED FRAME
SEOR STRUCTURAL ENGINEER OF RECORD
SW SHEAR WALL
INCORPORATEDUL UNDERWRITERS’ LABORATORY,
EXP EXPANSION
CONFIG CONFIGURATION
S1S SURFACED ONE SIDE
S4S SURFACED FOUR SIDES
INSUL INSULATION
JST JOIST
V, VERT VERTICAL
HEF HORIZONTAL EACH FACE
HIF HORIZONTAL INSIDE FACEHOF HORIZONTAL OUTSIDE FACE
VEF VERTICAL EACH FACE
VIF VERTICAL INSIDE FACEVOF VERTICAL OUTSIDE FACE
K KIP (1,000 POUNDS)
CU CUBIC
YD YARD
STEEL CONSTRUCTIONAISC AMERICAN INSTITUTE OF
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
OF BUILDING OFFICIALSICBO INTERNATIONAL CONFERENCE
CUT FROM W SHAPEWT WEIGHT; STRUCTURAL TEE
R RADIUS
GA GAGE,GAUGE
DEMO DEMOLISH; DEMOLITION
P PIPE
AR ANCHOR ROD
BOS BOTTOM OF STEEL; BOSOM (WELD)
d PENNY (NAIL)
DN DOWNDO DITTO
(E) EXISTINGE EASTE-W EAST-WEST
FRMG FRAMING
FG FRICTION GRIP BOLT
GL GLUED LAMINATED (BEAM)
H HORIZONTAL
HGR HANGER
MF MOMENT FRAME
MFR MANUFACTURE; MANUFACTURERMFRG MANUFACTURING
MFB MOMENT FRAME BEAMMFC MOMENT FRAME COLUMN
ML MATCH LINE
N-S NORTH-SOUTH
PLC PLACE
REINFORCEMENTREINF REINFORCE; REINFORCING;
S AMERICAN STANDARD SHAPE; SOUTH
SCC STRUCTURAL CONSULTANT TO
SCHED SCHEDULE; SCHEDULED
SHTG SHEATHING
SPC SPACE
TRANS TRANSVERSE
UB UNIVERSAL BEAM
UC UNIVERSAL COLUMN
W WIDE FLANGE, WIDE, WEST
WF WIDE FLANGE
WL WORK LINE
MEP MECHANICAL/ ELECTRICAL/PLUMBING
MS MECHANICAL SPLICE
PLF POUNDS PER LINEAL FOOT
LSW LIGHT GAGE SHEARWALL
@ AT
HSS HOLLOW STRUCTURAL SECTION
, DEG DEGREE
# NUMBER, POUND~, DIA DIAMETER
LB, # POUND
STUD
DIRECTION OF SPAN
STEEL ROOF DECK
CONCRETE WALL
CONCRETE COLUMN EARTH
GRAVEL
MATCHLINE
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
DETAIL NUMBER
GRID LINES
EXISTING ELEMENTS
COLUMN FOOTING
COLUMN
BEAM
ONE-WAY SLAB
WALL FOOTING
F12
C4
WF2
NORTH ARROW
ANCHORCONCRETEDRILLED IN
SPAN MARKLIMIT OF DECK OR
WALL OPENINGFLOOR OR
LONGITUDINALSTEEL FLOOR DECK
TRANSVERSESTEEL FLOOR DECK
ELEVATIONTOP OF FLOOR
ELEVATIONS)(ON SHEAR WALLWALL PENETRATION
DETAIL
SECTION
PLAN VIEWSECTION
MFB3
B3
S1
2NOTE
1
dh
1
dh
2N
OTE
E
J
NOTEL , MIN NOTEL , MIN
A
14 13 12
8 9
3 4 10
16 20 19
2
EL
N
D
D
2 " MIN4db OR
DRAWING NUMBER
ARCHITECTURAL PROFILE
FUTURE CONSTRUCTION
LD LT LSB LC LCSLSBT LB
X N
THE CONTRACTOR
PH PENTHOUSE
NWC NORMAL WEIGHT CONCRETE
LWC LIGHT WEIGHT CONCRETE
LENGTHS BY 20%.3. FOR EPOXY COATED HOOKS, INCREASE THE ABOVE EMBEDMENT
2. BAR DIMENSION REQUIRED TO MANUFACTURE HOOK.
END COVER 2" SIDE COVER 2 "1. ABOVE VALUES VALID FOR ALL CASES IF:
NOTES:
STRUCTURAL STEEL
WWF WELDED WIRE FABRICWWR WELDED WIRE REINFORCEMENT
CP, CJP COMPLETE JOINT PENETRATION
PP, PJP PARTIAL JOINT PENETRATION
CJP COMPLETE JOINT PENETRATION
DBA DEFORMED BAR ANCHOR
3/S5.31
4/S5.31
CONCRETE SCHEDULE MARKS
db db
12db
STANDARD HOOKS AND EMBEDMENT
REINFORCEMENTWELDED WIRE
AESS ARCHITECTURAL EXPOSED
MEZZ MEZZANINE
PJP, PP PARTIAL JOINT PENETRATION
db BAR DIAMETER
THK THICK;THICKNESS
BEAMPOST-TENSIONED
PTB3
MOMENT FRAME BEAM
SEE "TABLE A" SEE "TABLE A"
ANCHOR RODCONCRETE
TO PLANIF NOT SHOWN, REFERVERTICAL OFFSET,
9"
TOP OF SLAB
CONFIGURATION.UPON SLAB VARY DEPENDINGSYMBOL USED WILLSYMBOL. ACTUALTHIS IS A GENERIC
NOTE:
BOLT
REINFORCING BARSLAB AND SHEAR WALL T1
WALL ELEVATION)BEAM (ON SHEARSHEAR WALL COUPLING
WELD
LD
LD
LD
LD
LD
LT
LB
LC
LCS
LSB
LSBT
: LAP SPLICE LENGTH OF HORIZONTAL BARS IN THICK CONCRETE = 1.69 x (INCHES) : TYPICAL LAP SPLICE LENGTH = 1.3 x (INCHES) : SPIRAL COLUMN LAP SPLICE IN COMPRESSION = 22.5 x db (INCHES) : TIED COLUMN LAP SPLICE IN COMPRESSION = 30 x db (INCHES) : DEVELOPMENT LENGTH OF BARS OR DOWELS IN COMPRESSION = 19 x db (INCHES) : DEVELOPMENT LENGTH OF HORIZONTAL BARS IN THICK CONCRETE = 1.3 x (INCHES) BEAMS AND COLUMNS: CLEAR SPACING > db, AND CONCRETE CLEAR COVER > db SLABS AND WALLS: CLEAR SPACING > 2db, AND CONCRETE CLEAR COVER > db FOLLOWING REQUIREMENTS: : TENSION DEVELOPMENT LENGTH (INCHES) FOR REINFORCEMENT SATISFYING THE db : NOMINAL BAR DIAMETER (INCHES)1. NOTATIONS: NOTES:
6. MULTIPLY VALUES IN THE TABLE BY 1.3 FOR USE WITH LIGHTWEIGHT AGGREGATE CONCRETE. 5. #14 AND #18 BARS SHALL NOT BE LAP SPLICED. SEE "GENERAL NOTES." 4. THE DEVELOPMENT AND SPLICE LENGTHS ARE BASED ON REINFORCEMENT STRENGTH Fy = 60 KSI. CONCRETE CAST BELOW. THIS INCLUDES BEAMS, SLABS, FOUNDATIONS, AND WALLS. 3. "HORIZONTAL BARS IN THICK CONCRETE" REFERS TO BARS WITH MORE THAN 12 INCHES OF FRESH REQUIREMENTS FOR IN NOTE 1.2. MULTIPLY VALUES IN THE TABLE BY 1.5 IF CLEAR SPACING OR CONCRETE COVER DO NOT MEET THE
7 10
S5.02S5.01
S4.01
S3.02S3.01
S2.02RS2.02S2.01RS2.01S2.00RS2.00
S0.02S0.01
SECTIONS AND DETAILSSECTIONS AND DETAILS
COUPLING BEAM DETAILSTYPICAL POST-TENSIONED SLAB AND
SHEARWALL SECTIONSSHEARWALL ELEVATIONS
LOADING BLOCK REINFORCING PLANLOADING BLOCK PLANTYPICAL FLOOR REINFORCING PLANTYPICAL FLOOR PLANFOUNDATION BLOCK PLAN REINFORCING PLANFOUNDATION BLOCK PLAN
GENERAL NOTESABBREVIATIONS, LEGENDS, AND SYMBOLS
A
S0.02
NOTESGENERAL
2/22/2012
1:2
1:1
6 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
0_02
GE
NN
OT
ES.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
20 GENERAL NOTES
GENERAL
ALL TYPICAL DETAILS AND NOTES SHOWN ON DRAWINGS SHALL APPLY UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. WHERE TYPICAL DETAILS ARE NOTED ON THE DRAWINGS, THE SPECIFIED TYPICAL DETAIL SHALL BE USED. WHERE NO DETAIL IS NOTED, IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO CHOOSE THE APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED. THE CONTRACTOR SHALL SUBMIT ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH RELATED CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING PRODUCTION AND FIELD USE.
BUILDING CODE
ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE BUILDING STANDARDS. THE PUBLICATIONS LISTED BELOW ARE THE GOVERNING CODES AND STANDARDS AND ARE REFERENCED BY THEIR BASIC DESIGNATION. IN THE CASE OF CONFLICTING REQUIREMENTS, THE BUILDING CODE SHALL GOVERN.
APPLICABLE CODES AND STANDARDS
ACI 318 AMERICAN CONCRETE INSTITUTE, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE," 2008 EDITION
AISC 341 AMERICAN INSTITUTE OF STEEL CONSTRUCTION, "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS," 2005 EDITION, INCLUDING SUPPLEMENT NO. 1
AISC 360 AMERICAN INSTITUTE OF STEEL CONSTRUCTION, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS," 2005 EDITION
ASCE 7 AMERICAN SOCIETY OF CIVIL ENGINEERS, "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES," 2005 EDITION, INCLUDING SUPPLEMENTS NO. 1 AND NO. 2
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM INTERNATIONAL)
ICC INTERNATIONAL CODE COUNCIL, INTERNATIONAL CODE COUNCIL - EVALUATION SERVICES (ICC-ES)
CONCRETE
MIXING, BATCHING, TRANSPORTING, PLACING, AND CURING OF ALL CONCRETE, AND SELECTION OF CONCRETE MATERIALS, SHALL CONFORM TO ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE," EXCEPT AS NOTED BELOW. PROPORTIONS OF AGGREGATE TO CEMENTITIOUS PASTE SHALL BE SUCH AS TO PRODUCE A DENSE, WORKABLE MIX THAT CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER.
MIX DESIGNS LISTED BELOW SHALL BE SUBMITTED TO THE LABORATORY AND APPROVED PRIOR TO USE. SELECTION OF CONCRETE MIX PROPORTIONS SHALL BE IN ACCORDANCE WITH ACI 301. MIX PROPORTIONS SHALL MEET OR EXCEED THE REQUIREMENTS LISTED BELOW FOR THE LOCATIONS NOTED. THE MORE STRINGENT OF THE REQUIREMENTS LISTED SHALL GOVERN.
MAXIMUM FLY ASH AS A PERCENTAGE OF TOTAL WEIGHT OF CEMENTITIOUS MATERIAL SHALL BE 30 PERCENT. FLY ASH SHALL BE CLASS C OR CLASS F, MEETING ASTM C618 REQUIREMENTS. WATER/CEMENT RATIO SHALL BE BASED ON TOTAL CEMENTITIOUS MATERIAL, INCLUDING FLY ASH AND OTHER POZZOLANIC MATERIALS. MAXIMUM SIZE OF AGGREGATE SHALL BE AS LISTED BELOW.
ALL CONCRETE USED IN HORIZONTAL SURFACES EXPOSED TO THE WEATHER SHALL CONTAIN AN ACCEPTABLE ADMIXTURE TO PRODUCE AIR-ENTRAINED CONCRETE WITH TOTAL AIR CONTENT AS NOTED IN THE CONCRETE MIX SPECIFICATION TABLE. TOLERANCE FOR AIR CONTENT SHALL BE +/-1 PERCENT. AIR CONTENT SHALL BE MEASURED AT THE DISCHARGE OF THE TRUCK. IF CONCRETE IS PUMPED, AIR CONTENT SHALL BE MEASURED AT THE DISCHARGE END OF THE PUMP LINE. TESTS FOR AIR CONTENT SHALL MEET ASTM C172 REQUIREMENTS.
THE CONTRACTOR SHALL DETERMINE SLUMP. EACH CONCRETE MIX SUBMITTED SHALL HAVE THE SLUMP SPECIFIED. SLUMP SHALL BE MEASURED AT THE DISCHARGE OF THE TRUCK. IF CONCRETE IS PUMPED, SLUMP SHALL BE MEASURED AT THE DISCHARGE END OF THE PUMP LINE. SLUMPS SHALL BE WITHIN +1 INCH AND -2 INCHES OF THE SPECIFIED SLUMP.
THE USE OF SUPER PLASTICIZERS AND WATER REDUCERS IS ALLOWED, BUT NOT REQUIRED. ALL ADMIXTURES SHALL BE CHLORIDE FREE UNLESS OTHERWISE APPROVED BY THE ENGINEER.
CONCRETE MIX SPECIFICATION TABLE
f’c TEST MAX MAX AIR MIN AGE W/C AGGREGATE CONTENTLOCATION (PSI) (DAYS) RATIO SIZE PERCENT
FOUNDATION AND 6,000 28 0.44 1" -LOADING BLOCK
POST-TENSIONED 6,000 28 0.40 " - SLABS
SHEAR WALLS 6,000 28 0.44 " -
REINFORCING STEEL
ALL REINFORCING SHALL BE NEW BILLET STOCK ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE. BARS SHALL BE SECURELY TIED IN PLACE WITH #16 GAGE MINIMUM ANNEALED BLACK WIRE. BARS SHALL BE SUPPORTED ON CHAIRS IN ACCORDANCE WITH THE CRSI MANUAL OF STANDARD PRACTICE. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH ACI 315, "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT." THE CONTRACTOR SHALL COORDINATE REINFORCING STEEL PLACEMENT DETAILS AND PROVIDE TEMPLATES FOR PLACING STEEL IN CONGESTED AREAS AS NECESSARY. SHOP DRAWINGS (INCLUDING PLACING PLANS AND ELEVATIONS) SHALL BE SUBMITTED TO, AND REVIEWED BY, THE LABORATORY/ENGINEER BEFORE STARTING FABRICATION.
OTHERWISE ON THE DRAWINGS. #14 AND #18 BARS SHALL BE SPLICED USING MECHANICAL COUPLINGS INCLUDING SPLICES WITH SMALLER BARS. #14 AND #18 BARS SHALL NOT BE LAP SPLICED. NO REINFORCING BARS SHALL BE SPLICED BY WELDING. HEADED BARS OR TERMINATORS SHALL BE PROVIDED WHERE INDICATED ON THE DRAWINGS. HEADED BARS OR TERMINATORS SHALL MEET THE REQUIREMENTS OF ACI 318 AND ASTM A970, AND HAVE A CURRENT ICC-ES REPORT.
WELDING OR TACK WELDING OF REINFORCING BARS TO OTHER BARS OR TO PLATES, ANGLES, ETC, IS PROHIBITED, EXCEPT WHERE SPECIFICALLY APPROVED BY THE ENGINEER. WHERE WELDING IS APPROVED, IT SHALL BE DONE BY AWS CERTIFIED WELDERS USING E9018 OR APPROVED ELECTRODES. WELDING PROCEDURES SHALL CONFORM TO THE REQUIREMENTS OF AWS D1.4.
MINIMUM CAST-IN-PLACE CONCRETE COVER OVER REINFORCING STEEL, UNLESS NOTED OTHERWISE, SHALL BE AS FOLLOWS:
1. FOUNDATION AND LOADING BLOCK: 1 INCH
2. SLABS AND BEAMS: INCH
3. WALLS: INCH
SPECIFIED CONCRETE COVER SHALL BE MAINTAINED TO ALL REINFORCEMENT AT CONCRETE REVEALS AND INSETS. SHOP DRAWINGS SHOWING CONCRETE REVEALS AND OTHER INSETS SHALL BE SUBMITTED FOR REVIEW.
SPECIAL DUCTILE QUALITY REINFORCING STEEL
VERTICAL REINFORCING IN WALLS, LONGITUDINAL AND DIAGONAL REINFORCING IN COUPLING BEAMS, AND ALL OTHER REINFORCING MARKED "SDQ" SHALL BE LOW-ALLOY STEEL DEFORMED ASTM A706. BILLET STEEL ASTM A615, GRADE 60 REINFORCEMENT MAY BE USED IN THESE MEMBERS IF (1) THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED THE SPECIFIED YIELD STRENGTH BY MORE THAN 18,000 PSI AND (2) THE RATIO OF THE ACTUAL ULTIMATE TENSILE STRENGTH TO THE ACTUAL TENSILE YIELD STRENGTH IS NOT LESS THAN 1.25. IF MILL REPORTS ARE NOT AVAILABLE, THE REINFORCING SHALL BE TESTED PER THE SPECIFICATIONS AT THE CONTRACTOR’S EXPENSE.
POST-TENSIONED PRESTRESSED CONCRETE POST-TENSIONING SHOP DRAWINGS, INCLUDING PLANS AND DETAILS, SHALL BE SUBMITTED TO AND REVIEWED BY THE LABORATORY BEFORE STARTING FABRICATION.
IN ADDITION TO THE REQUIREMENTS IN THE CONCRETE MIX SPECIFICATION TABLE NOTED ABOVE, ALL POST-TENSIONED CONCRETE SHALL HAVE A MINIMUM STRENGTH OF 3,000 PSI AT TIME OF INITIAL STRESS. THE CONTRACTOR SHALL SUBSTANTIATE CONCRETE STRENGTH BEFORE POST-TENSIONING.
POST-TENSIONING REINFORCEMENT SHALL BE UNBONDED, LOW RELAXATION, 270-KSI HIGH-TENSILE WIRE STRAND CONFORMING TO ASTM A416, WITH DIAMETER AS NOTED ON THE DRAWINGS.
POST-TENSIONING TENDONS SHALL BE ENCASED IN WATERPROOF POLYETHYLENE PLASTIC SHEATHING OF 50 MILS MINIMUM THICKNESS. SHEATHING SHALL BE OF SUFFICIENT STRENGTH TO PREVENT UNREPAIRABLE DAMAGE DURING FABRICATION, TRANSPORTATION, INSTALLATION, STORAGE, CONCRETE PLACEMENT, AND TENSIONING.
TENDONS SHALL BE INSTALLED WITH A PARABOLIC DRAPE UNLESS NOTED OTHERWISE AND SHALL BE HELD IN THEIR DESIGNED POSITIONS AS SHOWN ON THE DRAWINGS. TENDON STRESSING, INCLUDING THE REQUIRED JACKING FORCES AND SEQUENCE OF TENDON STRESSING, SHALL BE AT THE DIRECTION OF THE LABORATORY.
NO CONCRETE SHALL BE PLACED UNTIL THE POST-TENSIONING TENDONS AND
LABORATORY.
CONSTRUCTION JOINTS
ALL CONSTRUCTION JOINTS IN SLABS, BEAMS, AND WALLS SHALL BE KEYED IN ACCORDANCE WITH THE TYPICAL DETAILS OR, AT THE CONTRACTOR’S OPTION, SHALL BE INTENTIONALLY ROUGHENED IN ACCORDANCE WITH THE FOLLOWING: THE SURFACE OF ROUGHENED JOINTS SHALL BE SAND BLASTED OR ROUGHENED WITH A CHIPPING HAMMER TO EXPOSE THE AGGREGATE EMBEDDED IN THE PREVIOUS POUR. THE EXPOSED AGGREGATE SHALL PROTRUDE A MINIMUM OF INCH. ALL SURFACES OF CONSTRUCTION JOINTS SHALL BE CLEANED AND LAITANCE REMOVED. IMMEDIATELY BEFORE NEW CONCRETE IS PLACED, ALL CONSTRUCTION JOINTS SHALL BE WETTED AND STANDING WATER REMOVED.
VERTICAL CONSTRUCTION JOINTS IN WALLS SHALL BE HELD TO A MAXIMUM SPACING OF 40’-0".
ALL CONSTRUCTION JOINTS IN SLABS, BEAMS, AND WALLS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE STARTING CONSTRUCTION. PROVIDE JOINTS AT LOCATIONS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS.
SLEEVES
EXCEPT AS DETAILED ON STRUCTURAL DRAWINGS, NO CONCRETE FOOTINGS, BEAMS, OR GIRDERS SHALL BE SLEEVED FOR PIPING OR DUCTS, UNLESS APPROVED BY THE ENGINEER.
NONSHRINK GROUT FOR BASE PLATES, SLEEVES, AND EMBEDDED STEEL
GROUT SHALL BE AN APPROVED NONSHRINK CEMENTITIOUS GROUT CONTAINING NATURAL AGGREGATES DELIVERED TO THE JOB SITE IN FACTORY PREPACKAGED CONTAINERS REQUIRING ONLY THE ADDITION OF WATER. THE MINIMUM 28-DAY COMPRESSIVE STRENGTH SHALL BE AT LEAST 1,000 PSI HIGHER THAN THE SUPPORTING CONCRETE STRENGTH, UNLESS NOTED OTHERWISE. GROUT SHALL BE MIXED, APPLIED, AND CURED STRICTLY IN ACCORDANCE WITH THE MANUFACTURER’S PRINTED INSTRUCTIONS. FOR GROUTING UNDER BASE PLATES, GROUT SHALL BE PROPORTIONED AS A FLOWABLE MIX. WHEN A FLOWABLE MIX DOES NOT PROVIDE THE REQUIRED STRENGTH OR WHEN A MINIMUM STRENGTH OF 10,000 PSI IS REQUIRED, AN EPOXY GROUT SHALL BE USED.
ANCHOR RODS
ANCHOR RODS SHALL BE ASTM A193 GRADE B7 WITH CLASS 1A THREADS, UNLESS NOTED OTHERWISE. FURNISH ANCHOR RODS PREFABRICATED WITH MATCHING HEAVY HEX NUT AND WASHER JAMMED AT THE END EMBEDDED IN CONCRETE. HOOKED ANCHOR RODS SHALL NOT BE USED EXCEPT WHERE NOTED. A RIGID STEEL TEMPLATE SHALL BE USED TO LOCATE ANCHOR RODS WHILE PLACING CONCRETE. ANCHOR RODS SHALL HAVE SUFFICIENT LENGTH TO PROVIDE THE MINIMUM EMBEDMENT SHOWN ON THE DRAWINGS, MEASURED FROM THE FACE OF THE CONCRETE TO THE NEAR FACE OF THE WASHER, WITH ADEQUATE EXTENSION AS REQUIRED TO RECEIVE THE BASE PLATE WITH FULL THREAD PROJECTION FOR NUT INSTALLATION. ANCHOR ROD INSTALLATION SHALL BE COORDINATED WITH REINFORCING AND FORMWORK. LEVELING NUTS SHALL NOT BE USED.
STEEL DECK
THE STEEL DECK SHALL BE OF DEPTH AND GAGE SHOWN ON THE STRUCTURAL DRAWINGS. SHOP DRAWINGS SHALL BE SUBMITTED SHOWING DECK GAGE, LAYOUT, CONNECTIONS, AND CLOSURES. STEEL DECK SHALL CONFORM TO ASTM A653. THE STEEL SHALL HAVE RECEIVED, BEFORE BEING FORMED, A METAL PROTECTIVE COATING OF ZINC CONFORMING TO ASTM A653-G60. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3. PROVIDE FLASHING AND CLOSURE PLATES AT ALL PERIMETER LOCATIONS REQUIRING CLOSURE.
STEEL DECK TYPES SHALL BE VERCO TYPE N-24, OR APPROVED EQUAL.
BUILDING TOLERANCES
STANDARD TOLERANCES SHALL BE BASED ON THE REQUIREMENTS OF THE AISC CODE OF STANDARD PRACTICE AND ACI 117, STANDARD SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS.
MISCELLANEOUS
WHERE SECTIONS ARE INDICATED ON THE PLAN BY A NUMBER AND A DRAWING NUMBER THUS, 1/S5.01, THE INDICATED SECTION (1) IS SHOWN ON STRUCTURAL DRAWING S5.01.
REINFORCEMENT LOCATIONS HAVE BEEN INSPECTED AND APPROVED BY THE
REINFORCING BARS SHALL BE LAP SPLICED FOR TENSION (L ) UNLESS NOTED SB
S2.00
BLOCK PLANFOUNDATION
2/21/2012
12:2
1:5
3 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
2_00_F
DN
PL
AN.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
A B C
1
2
3
5’-5 "6’-3 "6’-3 "5’-5 "
2’-11 "
6’-3 "
6’-3 "
2’-11 "
PLAN " = 1’-0"
5’-0"
2’-6"
2’-6"
5’-0"
5’-0"2’-6"2’-6"5’-0"
6" TYP6" TYP
N
5’-0"
5’-0"
LOCSTYP (2) 5/S5.01
LOCSTYP (4)3/S5.01
TYPI.D. 5 " MIN,PVC SLEEVE,
PER 20/S5.01TENDONS, LAYOUT(40) 0.6" BOTTOM
PER 20/S5.01TENDONS, LAYOUT(60) 0.6" TOP
14/S5.01TYP AT PERIMETER
STL D
EC
KSIM,
TYP A
T
14/S
5.0
1
20/S5.01
15/S5.01TYP (32) LOCS
TYP
TYP
NOTES
14"14"
2’-6" 2’-6"
15"
15"
15"
12 "
2’-11 "2’-11 "
PER 18/S5.01TENDONS, LAYOUT(22) 0.6" BOTTOM
PER 18/S5.01TENDONS, LAYOUT(34) 0.6" TOP
18/S
5.0
1
12 "
TYP
TYP TYP TYP TYP
14" 14"
TYPTYPTYPTYP
SIDES OF DECK, TYPSEPARATE CONC ON BOTHCLOSURE PLATES TO FULLYDECKING, PROVIDE STL AT INTERSECTIONS OF STL
2. FOUNDATION IS A 4’-0" THICK POST-TENSIONED MAT FOUNDATION.
THE REFERENCE ELEVATION. 1. REFERENCE ELEVATION IS 4’-0". TOP OF FOUNDATION IS AT
POST-TENSIONING, TYP (7) LOCSPROVIDE HOLES FOR TRANSVERSE FULL DEPTH OF FOUNDATION BLOCK, TO BE COORDINATED W/ LABORATORY,STL DECK, SIZE & ORIENTATION
S2.00R
REINFORCING PLANBLOCK PLAN
FOUNDATION
2/21/2012
12:2
1:5
1 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
2_00
R_F
DN_
REIN
F_P
LA
N.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
N
C B A
1
2
3
REINFORCING PLAN
T & B#6 @ 12"
HORIZ REINFLOC AT INTERSECTIONS OF#6x @ 24" EW, VERTICAL,
PORTION OF BAR.3. LENGTH OF HOOKED BARS AS SCHEDULED REFERS TO STRAIGHT
REINFORCING NOTES
- E-W TOP BARS - N-S TOP BARS - N-S BOTTOM BARS - E-W BOTTOM BARS SEQUENCE:4. SLAB REINFORCING BARS SHALL BE PLACED IN THE FOLLOWING
1. SEE THE "GENERAL NOTES" FOR GENERAL REINFORCING REQUIREMENTS.
2. CENTER REINFORCEMENT ON WALL CENTERLINES UNLESS NOTED OTHERWISE.
T & B#6 @ 12"
6’-3 "6’-3 "
6’-3 "
6’-3 "
S2.01
FLOOR PLANTYPICAL
2/21/2012
12:2
1:5
6 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
2_01_F
LR
PL
AN.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
A B C
1
2
3
2’-6 "6’-3 "6’-3 "2’-6 "
3’-8 "
6’-3 "
6’-3 "
3’-8 "
PLAN " = 1’-0"
N
3’-2 "3’-2 "
3’-0"
3’-0"
3’-0"
3’-0"
1. REFERENCE FLOOR ELEVATIONS ARE AS FOLLOWS:
LEVEL 3: 18’-0" LEVEL 2: 14’-0" LEVEL 1: 10’-0"
NOTES
THE "TYPICAL POST-TENSIONED SLAB DETAILS." TENSIONED TWO-WAY SLAB UNLESS NOTED OTHERWISE. SEE 2. STRUCTURAL SLAB IS A 3 INCH THICK UNBONDED POST-
TOP OF SLAB IS AT THE REFERENCE ELEVATION.
1’-1"1’-1"
TYP
1’-8 "
TYP
7 "
TYP
7
"
TYP
" TYP
"
1"~ HOLES
1"~ HOLES
EQ SPCG(2) " TENDONS
2 " 2 " "
2
"2
"2
"
(9) " TE
ND
ONS
EQ SPCG(2) " TENDONS
2 " 2 " "
2
"2
"2
"
(9) " TE
ND
ONS
TYP UNO2"~ HOLE,
S2.01R
REINFORCING PLANTYPICAL FLOOR
2/21/2012
12:2
1:5
5 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
2_01R_F
LR_P
LA
N_
REIN
F.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
" = 1’-0"
N
REINFORCING PLAN
1
2
3
A B C
6’-3 "6’-3 "
6’-3 "
6’-3 "
PORTION OF BAR.3. LENGTH OF HOOKED BARS AS SCHEDULED REFERS TO STRAIGHT
REINFORCING NOTES
- E-W TOP BARS - N-S TOP BARS - N-S BOTTOM BARS - E-W BOTTOM BARS SEQUENCE:4. SLAB REINFORCING BARS SHALL BE PLACED IN THE FOLLOWING
1. SEE THE "GENERAL NOTES" FOR GENERAL REINFORCING REQUIREMENTS.
MARK REINFORCING REMARK
T1
T2
T3
MARK REINFORCING REMARK
BOTTOM REINFORCING SCHEDULE
B1
B2
B3
B4
#3x4’-10" @ 18"
TOP REINFORCING SCHEDULE
MARK REINFORCING REMARK
X1
X2
X3
X4
CTR AT CORNER
TRIM REINFORCING SCHEDULE
2. CENTER REINFORCEMENT ON WALL CENTERLINES UNLESS NOTED OTHERWISE.
HOOK AT END#3x3’-0" @ 10"
#3x6’-0" @ 10"
(5) #3x4’-10" @ 5"
HOOK AT END#3x3’-0" @ 10"
#3x4’-10" @ 8"
#3x4’-10" @ 10"
CTR AT CORNER
TYP AT SLAB PERIMETER
(3) #5 @ 3", MID-DEPTH
(1) #3x2’-0" T&B
(1) #4x4’-0" TOP
#3 CONT, MID-DEPTH
B2
T2
B1
T2
B1 B2
T2
B1
B3
T2
B3
T2
X4 X4
X4 X4
X1
B2
T2
B1
T2
B1 B2
T2
B1
B3
T2
B3
T2
X4 X4
X1
X1
T3
B4
T3
B4
X1
TYP (4) LOCS X3
T1
TYP
1’-6
"
(1) #3 T&B
(1) #3 TOP
(1) #3 TOP
X2 X2
X2
X2
TYP
1’-6"
(2) #3 BOT
(2) #3 BOT
T1
T1 T1
BOT#3 @ 16 "
S2.02
BLOCK PLANLOADING
2/21/2012
12:2
2:0
0 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
2_02_
LO
AD
PL
AN.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
PLAN " = 1’-0"
N
A B C
1
2
3
2’-6 "6’-3 "6’-3 "2’-6 "
2 "
6’-3 "
6’-3 "
2 "
2’-11"
2’-8"
2’-8"
2’-11"
2’-6"
1’-1
0 "
1’-1
0 "
2’-6" TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
2’-3"2’-3"
3’-10"3’-10"
TYP
4’-2"
4’-2"
TYP
TYP
1’-1 "5 "
1’-2 "
3"3"
5 "1’-1 "
6 " TYP6 " TYP
TYP (2) LOCSIN BLOCK MID-DEPTH, CONC FILLED, CTRHSS12x8x x17’-0",
(2) LOCSSLEEVE, TYP5 " I.D. PVC
3 "
3 "
7 "11 "
5 "
5 "
2 " TYP1’-4 "
TYP
TYP
TYP
1’-10 "1’-10 "
TYP (2) LOCSPVC SLEEVES,(4) 2 " I.D.
TYP (2) LOCSPVC SLEEVES,(4) 2 " I.D.
UNDERSIDE OF MATTYP (18) LOCS @ STUD IN CTR OF PL, GR50, W/ (1) 1"~x6" EMBED PL1"x6"x1’-0"
5/S5.025/S5.02OPP HAND
TYP (86) LOCS10/S5.02
5/S5.02 OPP HAND5/S5.02
9/S
5.0
2
2 "
TYP
2 "
TYP
NOTES
18/S
5.0
2
20/S5.02
OPP HAND20/S5.02
PER 18/S5.02TENDONS, LAYOUT(18) 0.6" TOP
PER 18/S5.02TENDONS, LAYOUT(18) 0.6" BOTTOM
PER 20/S5.02TENDONS, LAYOUT(15) 0.6" BOTTOM
PER 20/S5.02TENDONS, LAYOUT(15) 0.6" TOP
PER 20/S5.02TENDONS, LAYOUT(15) 0.6" TOP
PER 20/S5.02TENDONS, LAYOUT(15) 0.6" BOTTOM
PER 18/S5.02TENDONS, LAYOUT(18) 0.6" TOP
PER 18/S5.02TENDONS, LAYOUT(18) 0.6" BOTTOM
TYP TYP
18/S
5.0
2
2. FOUNDATION IS A 2’-2" THICK POST-TENSIONED MAT FOUNDATION.
THE REFERENCE ELEVATION. 1. REFERENCE ELEVATION IS 22’-9 ". TOP OF FOUNDATION IS AT
2’-0"
TYP
(4) 5" SPCS, TYP
1 "
TYP
4"
TYP
3 " TYP 4" TYP
5 " TYP
(11) 5
" SPCS,
TYP
(11) 5
" SPCS,
TYP
4" TYP
5 " TYP
3 " TYP
8 "
TYP
8 "
TYP
TYP
1 "
TYP
4"
TYP
1 " TYP 4" TYP4" TYP
1 " TYP
S2.02R
REINFORCING PLANLOADING BLOCK
2/21/2012
12:5
2:3
1 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
2_02
R_
LO
AD_P
LA
N_
REIN
F.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
N
" = 1’-0"
C B A
1
2
3
REINFORCING PLAN
PORTION OF BAR.3. LENGTH OF HOOKED BARS AS SCHEDULED REFERS TO STRAIGHT
REINFORCING NOTES
- E-W TOP BARS - N-S TOP BARS - N-S BOTTOM BARS - E-W BOTTOM BARS SEQUENCE:4. SLAB REINFORCING BARS SHALL BE PLACED IN THE FOLLOWING
1. SEE THE "GENERAL NOTES" FOR GENERAL REINFORCING REQUIREMENTS.
2. CENTER REINFORCEMENT ON WALL CENTERLINES UNLESS NOTED OTHERWISE.
REINFORCING.5. LOCATE VERTICAL REINFORCING AT INTERSECTIONS OF HORIZONTAL
FACE BAR(1) #9 MID-DEPTH
T&B(5) #9 @ 11"
T&B(2) #9 @ 12"
(2) #9 @ 12" T&B
(4) #9 @ 7" T&B
(64) #6 x VERT
(32) #9 x VERT
(2) #9 @ 8" T&B(3) #9 @ 8 " T&B
(2) #9 @ 10 " T&B
(2) #9 @ 12" T&B
VERT(10) #9 x
T&B(5) #9 @ 11"
(32) #9 x VERT
(2) #9 @ 12" T&B
(64) #6 x VERT
(4) #9 @ 7" T&B
FACE BAR(1) #9 MID-DEPTH
(2) #9 @ 8" T&B
(2) #9 @ 10 " T&B
(10) #9 x VERT
(3) #9 @ 8 " T&B
(2) #9 @ 12" T&B
VERT(10) #9 x
FACE BARDEPTH(1) #9 MID-
FACE BARDEPTH(1) #9 MID-
T&B(2) #9 @ 12"
VERT(10) #9 x
(65) #6 x VERT
(5) #9 @ 11" T&B
(65) #6 x VERT
(5) #9 @ 11" T&B
@ SLEEVESTOP MIDDLE BART&B, CTR ON GRID,(3) #9 @ 8 "
@ SLEEVESTOP MIDDLE BART&B, CTR ON GRID,(3) #9 @ 8 "
S3.01
ELEVATIONSSHEARWALL
2/21/2012
12:2
2:0
2 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
3_01_S
HR
WA
LL_
EL
EV.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
C B A 1 2 3
TYP
TYP
FDN
LVL 1
LVL 2
LVL 3
LDG BLK
17 19 20
15
NORTH - SOUTH WALL ELEVATION EAST - WEST WALL ELEVATION " - 1’-0" " - 1’-0" KEY PLAN
FDN
LVL 1
LVL 2
LVL 3
LDG BLK
3’-2 "
5’-2 "
1’-7 "1’-7 "
7 "7 "7 " 7 "
REINFORCING SCHEDULE AND NOTES
OPP H
AN
D17/S
3.0
1
19/S3.01OPP HAND
19/S3.01
17/S
3.0
1
A
LSBT
LD
SPLICE LENGTH BAR SIZE
"SHEAR WALL ELEVATIONS."8. SEE "SHEAR WALL SECTIONS" FOR REINFORCING NOT SHOWN ON
MARK REMARKSREINFORCING
SHEAR WALL REINFORCING SCHEDULE
V1
V2
V3
H1
H2
#4 @ 10" EF
#3 @ 10" EF
#6 @ 10" EF
#6 @ 5" EF
#4 @ 9" EF
26"32"38"
# 4# 5# 6
TYPICAL. 4. EXTEND TIE REINFORCING PATTERNS INTO FOUNDATION 2’-6",
BOTTOM OF FOUNDATION. OF VERTICAL BARS IN WALLS AND COLUMNS. HOOK DOWELS AT5. DOWELS INTO FOUNDATION ARE TO MATCH SIZE AND SPACING
THE SMALLER BAR AND OF THE LARGER BAR, TYPICAL. 7. HORIZONTAL LAP SPLICES SHALL BE THE LARGER OF OF
HOOK AT EDGE OF WALL OPENINGS
10/S3.02
V1
H1
V1 V2
H1
V2
11"11"
A
B
B
SEE NOTE 5SEE NOTE 5
10/S3.02
V3
H2
NOTES:
QUALITY. SEE "GENERAL NOTES" FOR CRITERIA.1. ALL VERTICAL REINFORCING SHALL BE SPECIAL DUCTILE
UNLESS NOTED OTHERWISE. 2. ALL VERTICAL REINFORCING IN A LINE HAS THE SAME BAR MARK,
BEAM DETAILS."3. DENOTES A COUPLING BEAM MARK, PER THE "COUPLING
LENGTHS AS FOLLOWS: 6. VERTICAL BAR SPLICES SHALL HAVE SPLICE
NOTE 6
TYP
20/S3.0220/S3.02
NOTE 6
TYP
3 "
3’-0" 2’-6"2’-6"3’-0"
TYPTYP TYP TYP
10/S5.01
TYP (6) LOCS
10/S5.01
TYP (6) LOCSTYP
LABORATORY, TYP (3) LOCSOF COREWALL, COORDINATE WITHLOOP FERRULE ON INSIDE FACE "~ DAYTON SUPERIOR F42
4" TYP
3 "
TYP
4" TYP
LABORATORY, TYP (6) LOCSOF COREWALL, COORDINATE WITHLOOP FERRULE ON INSIDE FACE "~ DAYTON SUPERIOR F42
9 "2 " 9 " 2 "
3 "
9 "2 "9 " 2 "
3 "
A C
1
3
S3.02
SECTIONSSHEARWALL
2/21/2012
12:2
2:0
4 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
3_02_S
HR
WA
LL_S
EC.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
C B A
1
2
3
20 10 1" = 1’-0"1" = 1’-0" LEVEL 1 SHEARWALL SECTION
C B A
1
2
3
CLEAR FROM END OF WALL. 3. WHERE HORIZONTAL REINFORCEMENT ENDS WITHOUT HOOK, EXTEND END OF BAR TO "
VERTICAL AND HORIZONTAL PLACEMENT. ENDS. CROSSTIE ORIENTATION SHALL BE ALTERNATED END FOR END FOR CONSECUTIVE2. EACH CROSSTIE SHOWN SHALL HAVE 90 DEGREE AND 135 DEGREE HOOKS AT OPPOSITE
1. ALL REINFORCEMENT IS DEFINED PER "SHEAR WALL ELEVATIONS" UNLESS NOTED HERE.
NOTES:
11"
11"
LSBT
HORIZ REINF, TYPSPCG TO MATCHU-BARS W/SIZE &
@ 4", TYP#3 CROSSTIES
@ 2", TYPCROSSTIE #3 HOOP &
TYP
LSBT
HORIZ REINF, TYPSPCG TO MATCHU-BARS W/SIZE &
@ 4", TYP#3 CROSSTIES
TYP
LSBT
HORIZ REINF, TYPSPCG TO MATCHU-BARS W/SIZE &
@ 4", TYP#3 CROSSTIES
TYP
CLEAR FROM END OF WALL. 3. WHERE HORIZONTAL REINFORCEMENT ENDS WITHOUT HOOK, EXTEND END OF BAR TO "
VERTICAL AND HORIZONTAL PLACEMENT. ENDS. CROSSTIE ORIENTATION SHALL BE ALTERNATED END FOR END FOR CONSECUTIVE2. EACH CROSSTIE SHOWN SHALL HAVE 90 DEGREE AND 135 DEGREE HOOKS AT OPPOSITE
1. ALL REINFORCEMENT IS DEFINED PER "SHEAR WALL ELEVATIONS" UNLESS NOTED HERE.
NOTES:
11"
11"
LEVELS 2 & 3 SHEARWALL SECTION
SHOWN, TYP (4) LOCSBEAM DETAILS IN LIEU OF REINFWALL CONFINING PER COUPLING AT COUPLING BEAMS, PROVIDE
GREATER WALL WIDTH, TYP.REBAR COVER TO ACCOMODATE LEVEL BELOW & INCREASE LOCATIONS & GEOMETRY FROM LEVEL 3, MAINTAIN REBAR AT THICKENED WALL ABOVE
S4.01
BEAM DETAILSSLAB AND COUPLING
POST-TENSIONEDTYPICAL
2/17/2012
9:5
2:4
7 A
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
4_01_P
T_S
LA
B_
DE
T.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O1/23/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
PL
AN
PT TENDON
1’-6"
TO PT CABLE RUNEDGES ARE NOT PERPGROMMETS WHERE SLABDIAG CUT LONGCONTR SHALL USE
TENDON ENDS ARE CUTW/ NON-SHRINK GROUT AFTERPOCKETS SHALL BE PACKEDEND ONLY. STRESSINGGROMMETS AT STRESSING
PT TENDONTO PT CABLE RUNEDGES ARE NOT PERPGROMMETS WHERE SLABDIAG CUT LONGCONTR SHALL USE
TENDON ENDS ARE CUT.W/ NON-SHRINK GROUT AFTERPOCKETS SHALL BE PACKEDEND ONLY. STRESSINGGROMMETS AT STRESSING
NOTED ON PLANSTAGGER REINF AS
1’-0
" CLR M
AX
SEE PLANTOP REINF
THESE DIM EW @ 12" MAX SPCGTOP REINF TO BE DISTRIBUTED W/
SPCG PER PLANDISTRIBUTED TENDONS,
SLAB EDGE
ON PLANS, TYPBM AS INDICATEDWALL, COL OR
REMAIN STRAIGHTTENDON SHALL
SEE PLANSADDED TENDONS,
CL SUPT CL SUPT CL SUPT
SHOWN ARE TO CG OF TENDON.NOTED ON PLANS. DIMSSLAB HIGH & LOW PTS ARETENDON DIM FROM BOT OF
REMAIN STRAIGHTTENDON SHALL
ADDED TENDON ANCHORABOVE & BELOWPROVIDE #4x3’-0"
PLUS DROP PANEL. D = DEPTH OF SLAB OR DEPTH OF SLAB W = COLUMN WIDTH2. LEGEND: DIRECTLY OVER COLUMN EACH WAY.1. A MINIMUM OF TWO TENDONS ARE TO PASS NOTES:
4. DRAPE TENDON IN PARABOLIC PROFILE BETWEEN LOW AND HIGH POINTS. CENTERLINE OF EXTERIOR SUPPORTS.3. TENDON LOW POINTS AT EXTERIOR SPANS ARE LOCATED 0.4xL FROM 5. DROP PANELS, WHERE THEY OCCUR, ARE NOT SHOWN FOR CLARITY.
1
PLACED AS SHOWNREINF MAY BE SECT A
SECT B
BANDED TENDONS DISTRIBUTED TENDONS
REINFORCING AT INTERIOR SUPPORT REINFORCING AT EXTERIOR SUPPORT
CANTILEVERED SLABINTERIOR SPANINTERIOR SUPPORTEXTERIOR SPANEXTERIOR SUPPORT
SECTION A
2 5
7 10
12 15
16 20
11
17
1’-0"2"
EQ
EQ SEE
2 " MIN 2 " MIN
EQ
EQ SEE
PL
AN
6"
CLR MIN
EQ
EQ
3’-6"
"L"
3’-6"
EQ
EQ
EQ
EQ
PLAN
SECTION B
SLAB EDGE" DET"TYP PT ANCHOR ATHAIRPIN BARS. SEE
TYPICAL POST-TENSIONED REINFORCING AT SUPPORT FOR TWO-WAY SLABS
TYPICAL POST-TENSIONED TENDON PROFILE
TYPICAL POST-TENSIONED ANCHOR AT SLAB EDGE
(6) TENDONS MAX PER BUNDLE
TENDON BUNDLE
TENDONS AT SKEW2" CLR BTWN
LAST TENDONLd MIN PAST
FOR EA BUNDLECURVED SECTIONOVER LENGTH OF#4 x @ 12"
WHERE OCCURSADJ BUNDLE OF TENDONS
TYPICAL SKEWED TENDONS
"X"
PT TENDONS
PT SLAB
PT SLAB
HAIRPINS& EXTENT OFPER NOTE 3CURVED SECTLENGTH OF
(6) PER BUNDLE, MAXBANDED TENDONS,
"W"1.5xD
6" MIN
6 " THICK SLAB OR LESSOR GREATER. 8" MIN FOR3" MIN FOR 7" THICK SLAB
3’-6"
TENDONSSTRAIGHT
SLOPEMAX HORIZ
1
12
6" MIN AT DEAD END COVER AT STRESSING END,
SEE NOTE 2TENDON ANCHOR,
SEE NOTE 2TENDON ANCHOR,
6" MIN AT DEAD END COVER AT STRESSING END,
2. PLACE ANCHORS VERTICALLY IN SLABS GREATER THAN OR EQUAL TO 7 INCHES THICK. PLACE ANCHORS HORIZONTALLY FOR SLABS LESS THAN 7 INCHES THICK.
1. BANDED TENDON DETAIL APPLIES FOR GROUPS OF FOUR OR MORE TENDONS WHERE ANCHOR SPACING IS LESS THAN 12 INCHES.
NOTES:
3. MINIMUM LENGTH OF CURVED SECTION IS EQUAL TO 20/X (IN FEET).2. WHERE "X" IS 12 OR GREATER, NO HAIRPINS ARE REQUIRED.1. LIMIT "X" TO 6 AT MINIMUM.
NOTES:
ALL BANDS LAST HAIRPIN. TYP ATEXTEND 1’-6" BEYONDGROUP W/ (2) #4 T&B,ANCHOR & EA END OF ANCHOR#4x HAIRPINS BTWN EA
1.5xD
"W"
1.5xD
1.5xD "W" 1.5xD
1.5xD
"W"
1.5xD
UNLESS NOTED OTHERWISE.2. TENDON LOW POINTS ARE LOCATED MIDWAY BETWEEN HIGH POINTS 1. SEE PLANS FOR TENDON LAYOUT. NOTES:
NOTED ON PLANSTAGGER REINF AS
LAST TENDON, MINEXTEND 6" BEYONDREQD & STAGGER,BARS, LAP 2’-6" AS(2) #4 CONT BACKUP
LAST TENDON, MINEXTEND 6" BEYONDREQD & STAGGER,BARS, LAP 2’-6" AS(2) #4 CONT BACKUP
TYPLABORATORY, TYPPROVIDED BY SLEEVES TO BE DEBONDED REBAR,
"4 "
TYPTYP
WALLEDGE OF
SECTIO
N
HOOPS @ 7"(3) TYPE 1
12" TYP
2 HOOPS @ 2 "(4) TYPE 1 & TYPE
FOR CLARITYNOT SHOWN WALL REINF
EQ
EQ
6 "6 "
"
CLR
" CLR ES
"
CLR
#3x TYPE 1 HOOPS
SHOWN FOR CLARITYSLAB REINF NOT
WITH LABORATORYAS SHOWN. COORDINATENOTCH BM & SLAB "AT EACH END OF BEAM,
REINF EF(4) #3 SKIN
#3x TYPE 2 HOOPS3 "
SECTION
9" TYP2’-2"
TYPE B COUPLING BEAM
TYPE A COUPLING BEAM
2 " TYP
CTR IN BMIN 1 " I.D. DUCT,(2) 0.6" TENDONS
WITH LABORATORY, TYP EA END OF BMCENTERED IN BM WIDTH, COORDINATEFERRULE TOP & BOT OF BM, "~ DAYTON SUPERIOR F42 LOOP
EXTENTS SHOWN@ 2" OC IN WALL OVER STEEL PER 10/S3.02CROSSTIES CONFINING PROVIDE #3 HOOPS &
TYP
T&
B5"
TYPLABORATORY, TYPPROVIDED BY SLEEVES TO BE DEBONDED REBAR,
"4 "
TYPTYP
WALLEDGE OF
SECTIO
N
HOOPS @ 7"(3) TYPE 1
12" TYP
2 HOOPS @ 2 "(4) TYPE 1 & TYPE
FOR CLARITYNOT SHOWN WALL REINF
EQ
EQ
6 "6 "
"
CLR
" CLR ES
"
CLR
#3x TYPE 1 HOOPS
SHOWN FOR CLARITYSLAB REINF NOT
WITH LABORATORYAS SHOWN. COORDINATENOTCH BM & SLAB "AT EACH END OF BEAM,
REINF EF(4) #3 SKIN
#3x TYPE 2 HOOPS3 "
SECTION
9" TYP2’-2"
2 " TYP
EXTENTS SHOWN@ 2" OC IN WALL OVER STEEL PER 10/S3.02CROSSTIES CONFINING PROVIDE #3 HOOPS &
TYP
T&
B5"
CTR IN BMIN 1 " I.D. DUCT,(2) " TENDONS
WITH LABORATORY, TYP EA END OF BMCENTERED IN BM WIDTH, COORDINATEFERRULE TOP & BOT OF BM, "~ DAYTON SUPERIOR F42 LOOP
(2) #3 T&B DEBONDED REINF
(2) #3 T&B DEBONDED REINF
S5.01
AND DETAILSSECTIONS
2/21/2012
12:2
2:0
5 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
5_01_
DT
LS.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
8 9
3
10
20
7
1
6
5
15
18
13 14 11 12
12"
#3x @ 4" SECTION
FDN
NUTS & WASHERSANCHOR RODS W/ MATCHING(2) 1 "~ A193 GRADE B7
3’-8"
EM
BE
DM
ENT
12"9"
PER PLAN, TYPFDN REINF
FRAME BY OTHERSBASEPLATE & REACTION
1" NON-SHRINK GROUT
SECTION
6"6"6"6"
6"
6"
PER PLANFDN REINF
(9) #6 VERTS
AR
12"
SECTION
FDN
3’-8"
EM
BE
DM
ENT
8"3 "
PER PLAN, TYPFDN REINF
1" NON-SHRINK GROUT
JACK BY OTHERSBASEPLATE &
ES STL DECK#3x @ 4"
NUTS & WASHERSANCHOR RODS W/ MATCHING(4) 1 "~ A193 GRADE B7
SECTION
WALL ELEVSPER SHEARWALL REINF
2"
4"
8"
4"
8"
2"
WALL ELEVSPER SHEARWALL REINF
PER PLANFDN REINF
(4) #6 VERTS ES
PER PLANSTL DECK
AR, TYP
2
FDN
EQ
EQ
EQ
AT SIMSTL DECK
#6x @ 12"
PER PLANFDN REINF
DETAILDETAIL 1" = 1’-0"1" = 1’-0"
1" = 1’-0"1" = 1’-0" SECTION SECTION
DETAIL
6"
6"
3"
6"
3"
(20) BOT TENDONS
(20) TOP TENDONS
FDN
LABORATORY, TYPTO BE PROVIDED BYDEBONDED AR, SLEEVES
LABORATORY, TYPTO BE PROVIDED BYDEBONDED AR, SLEEVES
STL DECKEACH SIDE OF REINF SHOWN ON AT SIM, PROVIDE
HORIZ FACE BARS(2) #6 CONT.
FDN
PER PLAN, TYPFDN REINF
6 " TYP6 " TYP
6" TYP
NTS
1. FOUNDATION MILD REINFORCING NOT SHOWN FOR CLARITY.
NOTES:
PER SECTIONVERT REINF
PER SECTIONVERT REINF
DETAIL3" = 1’-0"
PER PLAN
TOS1 "
1’-3
"
3"3"
WALL ELEVSPER SHEARWALL REINF
I.D. 2"PVC SLEEVE, LENGTH OF WALL
EXTEND FULLABOVE SLEEVE,ADD (1) #3 EF
CLARITYSHOWN FORSLAB REINF NOT
ADD (2) #4x EF3’-0"
(20) TOP TENDONS
(20) TOP TENDONS
(20) BOT TENDONS
P-60 #6 TENSION BAR8-TON DAYTON SUPERIOR
P-53 LIFTING EYE8-TON DAYTON SUPERIOR
ADDED #3 HORIZ REINF HOOK EA END AROUND @ 4" OC, CTR ON SLEEVE,(6) #3x CROSSTIES
STL DECK PER PLAN6"
6"
3 "
6"
3 "
(10) BOT TENDONS
(10) TOP TENDONS
FDN
10" TYP10" TYP6" TYP
1. FOUNDATION MILD REINFORCING NOT SHOWN FOR CLARITY.
NOTES:
(12) TOP TENDONS
(12) TOP TENDONS
(12) BOT TENDONS
DETAILNTS
STL DECK PER PLAN, TYP
S5.02
AND DETAILSSECTIONS
2/21/2012
12:2
2:0
7 P
Muser: P2
Y pcf:
MK
A_
HY
BRID
_S
TR
UC
T plt
cf
g: P
DF F
S W
TS M
ON
O.P
LT
CF
G file: J:\
NO
TR
ED
AM
ES
HE
AR
WA
LL
TES
T\S
5_02_
DT
LS.D
GN
mo
del: S
HE
ET versio
n:
2
3
4
5
1
DRAWN: VA
CHECKED: JMM
JOB NUMBER: 96451.00
SCALE:
DATE: O2/21/2012
APPROVED:
DAMENOTRE
TESTSHEARWALL
REVISION DATE
8 9
3 4
10
20
2
7
1
6
5
15
18
13 14 11 12
DETAIL1" = 1’-0"
2
8 "8 "
4 "
2 "
2 "
11"
REINF PER PLANLDG BLOCK
LDG BLOCK
DETAIL1" = 1’-0"
LDG BLOCK
1’-8"
2"
TYP
6"
2"
TYP
6"
2" TYP
2"
TYP
"
CLR,
TYP T
&B
CL HSSCL EMBED
16"
40"
IN EACH PVC SLEEVE TO PREVENT BENDING OF SLEEVE. 1. DURING CONCRETE CASTING, INSERT 1 " THREADED RODS
NOTES:
ON EMBED IN PLANBELOW EMBED, CENTERED(1) #5 x ABOVE &
1 "~x 21" STUDSGR50, W/ (4) 1 " EMBED PL,
PVC SLEEVES(8) 2 " I.D.
TO EA END OF LOADING BLOCKABOVE & BELOW HSS, EXTEND(2) #7 CONT HORIZ FACE BARS
LDG BLOCK
3"3 "
3"
3 "
(8) TOP TENDONS
(7) TOP TENDONS
1. MAT MILD REINFORCING NOT SHOWN FOR CLARITY.
NOTES:
LDG BLOCK
3"
3"
3"
3"
(8) TOP TENDONS
1. MAT MILD REINFORCING NOT SHOWN FOR CLARITY.
NOTES:
2
12"12"
(10) BOT TENDONS
(8) BOT TENDONS
(10) TOP TENDONS
(8) BOT TENDONS
(7) BOT TENDONS
6"
2’-6"
" NON-SHRINK GROUT
LABORATORY, TYPTO BE PROVIDED BYDEBONDED REBAR SLEEVES
SHEAR WALL ELEVSWALL REINF PER
OF WALLEXTEND TO EA ENDADDL (3) #3 @ 6" HEF,
END ANCHORD-158-C #9 FEMALEDAYTON SUPERIOR
& LOC W/ LABORATORYCOORDINATE QUANTITYFOR GROUTING,2" I.D. SLEEVES
SLEEVE3" I.D. PVC
PER PLANMAT REINF
PROVIDED BY LABORATORYPL & WASHER TO BE
EQEQ, TYP
3" TYP
EQEQ, TYP
3" TYP
CROSSTIES @ EA WALL VERTADDL (3) ROWS OF #3 x
LDG BLOCK
DETAIL1" = 1’-0"
DETAILNTSDETAILNTS
8 UN THREADSALL-THREAD ROD W/ 1 "~ A193 GRADE B7
HSS PER PLAN