4
1 OF 4 IG022218-1.0 PASSIVE SENSOR SWITCH INSTALLATION GUIDE ® PASSIVE SENSOR SWITCH INSTALLATION GUIDE SKU DI-SWTH-PSV Input 12 - 24VDC Constant Voltage Output 12 - 24VDC Constant Voltage Max Load 12V 60W (5A), 24V 96W (4A) Ambient Temp -4° - 122°F (-20° - 50°C) SAFETY & WARNINGS QUICK SPECS / MODELS † Do not install product in environment outside listed temperature. POWER SUPPLY CLASS 2 VOLTAGE DROP LIMIT 3% ® PASSIVE SENSOR SWITCH 2 3 1 SENSOR INPUT VV+ V+ VPOWER INPUT OUTPUT TO LOAD DI-SWTH-PSV DRY LOCATION 24VDC 12VDC 1. Install in accordance with national and local electrical code regulations. 2. This product is intended to be installed and serviced by a qualified, licensed electrician. 3. Do not modify or disassemble this product beyond instructions or the warranty will be void. 4. Do not submerge, or install within 5 feet of a swimming pool. 5. Only install with a Listed Class 2 DC LED driver. 6. To avoid Voltage Drop, ensure wire gauge used with LED Strip Light is sufficient to keep under 3% voltage drop. 7. DO NOT connect directly to high voltage power. 8. Only install compatible 12V and 24VDC constant voltage luminaires. 9. This product is rated for indoor installation and is not protected against moisture. 10. Failure to follow safety warnings, and installation instructions will void the warranty for this product.
Transcript
Page 1: SAFETY & WARNINGS QUICK SPECS / MODELS...® PASSIVE SENSOR SWITCH INSTALLATION UIDE SKU DI-SWTH-PSV Input 12 ... 1. Install in accordance with national and local electrical code regulations.

1 OF 4 IG022218-1.0PASSIVE SENSOR SWITCH INSTALLATION GUIDE

® PASSIVE SENSOR SWITCHINSTALLATION GUIDE

SKU DI-SWTH-PSV

Input 12 - 24VDC Constant VoltageOutput 12 - 24VDC Constant Voltage

Max Load 12V 60W (5A), 24V 96W (4A)

Ambient Temp † -4° - 122°F (-20° - 50°C)

SAFETY & WARNINGS QUICK SPECS / MODELS

† Do not install product in environment outside listed temperature.

POWER SUPPLY

CLASS2

VOLTAGE DROPLIMIT

3%

®

PASSIVE SENSOR SWITCH23

1

SEN

SOR

INPU

T V−V+

V+

V−POW

ERIN

PUT

OU

TPU

TTO

LOAD

DI-SWTH-PSV

DRY LOCATION

24VDC12VDC

1. Install in accordance with national and local electrical code regulations.

2. This product is intended to be installed and serviced by a qualified, licensed electrician.

3. Do not modify or disassemble this product beyond instructions or the warranty will be void.

4. Do not submerge, or install within 5 feet of a swimming pool.

5. Only install with a Listed Class 2 DC LED driver. 6. To avoid Voltage Drop, ensure wire gauge used with

LED Strip Light is sufficient to keep under 3% voltage drop.

7. DO NOT connect directly to high voltage power.8. Only install compatible 12V and 24VDC constant

voltage luminaires.9. This product is rated for indoor installation and is not

protected against moisture.10. Failure to follow safety warnings, and installation

instructions will void the warranty for this product.

Page 2: SAFETY & WARNINGS QUICK SPECS / MODELS...® PASSIVE SENSOR SWITCH INSTALLATION UIDE SKU DI-SWTH-PSV Input 12 ... 1. Install in accordance with national and local electrical code regulations.

2 OF 4 IG022218-1.0PASSIVE SENSOR SWITCH INSTALLATION GUIDE

® PASSIVE SENSOR SWITCHINSTALLATION GUIDE

1. Appropriate Junction Box2. Class 2 rated Driver3. PASSIVE SENSOR SWITCH4. LED Tape Light

REQUIRED TOOLS

1 2 3

1. Phillips-head Screwdriver2. 7/16 inch Drill Bit3. Wire Stripper

AC IN

DC OUT

LGN

V −V+

+ −

REQUIRED COMPONENTS1 2 3 4

INSTALLATION

TURN POWER OFF AT CIRCUIT BREAKER

SHOCK HAZARD! May result in serious injury or death.Turn power OFF at circuit breaker prior to installalation.

DETERMINE LOCATION TO INSTALL COMPONENTS

*NOT FOR USE IN SUBMERSIBLE APPLICATIONS, OR WITHIN 5 FEET OF A SWIMMING POOL.Refer to SYSTEM DIAGRAMS

WIRE GAUGE & VOLTAGE DROPEnsure appropriate wire is installed between driver, fixture, and any controls in between. When choosing wire, factor in voltage drop, amperage rating, and type (in-wall rated, wet location rated, etc.) For more information, refer to system diagrams and voltage drop charts at the end of this document.

®

PASSIVE SENSOR SWITCH

23 1

SENSORINPUT

V−V+ V+V−

POWERINPUT

OUTPUTTO LOAD

DI-SWTH-PSV

1

2

Page 3: SAFETY & WARNINGS QUICK SPECS / MODELS...® PASSIVE SENSOR SWITCH INSTALLATION UIDE SKU DI-SWTH-PSV Input 12 ... 1. Install in accordance with national and local electrical code regulations.

3 OF 4 IG022218-1.0PASSIVE SENSOR SWITCH INSTALLATION GUIDE

PASSIVE SENSOR SWITCHINSTALLATION GUIDE

Loosen Nut

7/16 inches(10mm)

Insert

Tighten Nut

PASSIVE SENSOR PLACEMENT

a. Using a 7/16 inch Drill Bit, create a hole where you would like to place the Sensor.b. Loosen Nut from the Passive Sensor.c. Insert Passive Sensor into 7/16 inch hole.d. Tighten Nut onto back of Passive Sensor.

INSTALLATION (CONT.)

CONNECT PASSIVE SENSOR TO SWITCH

Ensure the Connector is facing correctly when inserted into Switch.(shown below)

WIRE DRIVER & LUMINAIRE TO SENSOR SWITCH

5/16 in. (8 mm)

b. Wire Class 2 driver and LED luminaire to Sensor Switch. See SYSTEM DIAGRAM.

a. Strip wires.

Loosen with Phillips-head screwdriver and insert wire. Then tighten terminal screw.

DI-SWTH-PRX

®

OCCUPANCY SENSOR SWITCH23

1SE

NSO

RIN

PUT V−

V+

V+

V−POW

ERIN

PUT

OU

TPU

TTO

LOAD

TURN POWER ON AT CIRCUIT BREAKER

3

4

5

6

Page 4: SAFETY & WARNINGS QUICK SPECS / MODELS...® PASSIVE SENSOR SWITCH INSTALLATION UIDE SKU DI-SWTH-PSV Input 12 ... 1. Install in accordance with national and local electrical code regulations.

4 OF 4

® Toll Free: 877.817.6028 | Fax: 415.592.1596 | www.DiodeLED.com | [email protected]© 2015 Elemental LED Inc. All rights reserved. Specifications are subject to change without notice.

IG022218-1.0PASSIVE SENSOR SWITCH INSTALLATION GUIDE

PASSIVE SENSOR SWITCHINSTALLATION GUIDE

SYSTEM DIAGRAM

+−

LED Array/Fixture

23

1

SEN

SOR

INPU

T V−V+

V+

V−

AC Power50/60Hz

Class 2 DC Constant Voltage Driver

AC IN

DC O

UT

LGN

V−

V+

PassiveSensor

V+V−

POWERINPUT

OUTPUTTO LOAD

OPERATION

On/Off Whenever an object passes completely through the sensor range.

Sensor Range < 2.3 inches

Sensory Angle 60°

Diameter for Drilling 7/16 inch Drill Bit. (10mm)

Prior to troubleshooting, turn power OFF at circuit breaker and verify all connections.

TROUBLESHOOTING

Symptom Common Cause

Luminaire does not illuminate

• Incorrect wiring.• Polarity of Low Voltage V+ and V- are

reversed. • Circuit breaker is OFF or tripped.• Incorrect voltage pairing of dimmer and

luminaire. 12V drivers models will not power a luminaire with a higher voltage rating.

• Connecting the Sensor Switch to a second Controller may result in a delayed response time.

Luminaire heats up excessively

• Incorrect voltage pairing of driver and luminaire. Do not attach a 12V luminaire to a 24V driver.

• Luminaire is not compatible. • Refer to luminaire install guide warnings

and safety tips.

PASSIVE SENSOR SWITCH SPEC SHEET For full specifications.

CONSTANT VOLTAGE DRIVER SPEC SHEET& INSTALL GUIDEFor full specifications and installation instructions.

LED TAPE LIGHT SHEET & INSTALL GUIDEFor full specifications and installation instructions.

ADDITIONAL RESOURCES<2.3 inches <2.3 inches

ON OFF


Recommended