+ All Categories
Home > Documents > sauter-controls.com SAUTER EGP100.The SAUTER EGP100 incorporates the lengthy experience and quality...

sauter-controls.com SAUTER EGP100.The SAUTER EGP100 incorporates the lengthy experience and quality...

Date post: 06-Feb-2021
Category:
Upload: others
View: 8 times
Download: 0 times
Share this document with a friend
4
SAUTER EGP100. Measures differential pressure precisely and is easy to fit.
Transcript
  • SAUTER EGP100.Measures differential pressure precisely and is easy to fi t.

  • 2

    Precision in every detail: for a complete energy-effi cient solution with the SAUTER EGP100.

    A versatile range of applications combined with absolute accuracy.

    Anyone with a commitment to energy effi ciency thinks in integrated terms. And anyone who wants to be successful at energy effi ciency will also examine every detail of the system. The SAUTER EGP100 incorporates the lengthy experience and quality awareness that we have acquired from devising complete solutions and from developing the instruments required to implement them. This trans-ducer for differential pressure can be used wherever there is a call for pressure monitoring with uncompromising precision. Examples include:• Air-conditioning• Medical technology• Environmental technology• Laboratories and clean rooms

    Exceptional requirements? Not a problem.

    The accurate measurement of positive, negative or differential pressure in gases has been optimised in the new SAUTER EGP100 so that it can bring all its strengths to bear when monitoring fi lters, ventilation ducts and ventilation sys-tems – even when the air contains dust or is contaminated with chemicals. Ad-ditional benefi ts include control of frequency converters to regulate ventilation and level monitoring for fl uids.

  • 3

    A little large at fi rst sight, but on close inspection it’s just right.

    Exact measurement using a double-membrane pressure sensor:

    this high-calibre sensor will even detect the most minimal air

    fl ows or differential pressures. A differential capacitive method

    of measurement is used to evaluate the differential pressure and

    make it available in the form of a linear electrical signal. Another

    advantage of the membrane sensor is that it can be fi tted in any

    position.

    The zero point can be set at any time thanks to the inte-

    grated potentiometer. The SAUTER EGP100 is also supplied

    ex works with a calibration certifi cate. The variable fi lter

    constant ensures that the output signal remains stable when

    measurement is diffi cult.

    Opening and positioning is easy. The cover closure with its

    hook and the latch on the housing cover ensure simple and

    safe handling for fi tting and maintenance. Minimum time

    and effort are required, and no additional tools are needed.

    IP 65 is included.

    Servicing is easy thanks to the automatic cable feed, which

    saves time and expense.

    The choice is yours. You can mount the SAUTER EGP100 to

    a wall or onto a top-hat rail as per the DIN standard: both

    are possible.

    Sen

    sor

    Pote

    ntio

    met

    erH

    ousi

    ng

    cove

    rC

    onne

    ctio

    nFi

    ttin

    g

  • Systems

    Components

    Services

    Facility Management

    AU ZU

    ABFO

    CI CIDO DODI DIAO AOAI AI

    1 11

    PDPD

    1

    LL

    113

    121

    13

    NN

    1

    NN

    1

    Rev.Rev.

    121

    13

    NN

    1

    NN

    1

    Rev.Rev.

    1

    H%H%

    1 11

    T

    1

    T

    1

    H%

    2

    T

    1

    H%

    1

    A-0

    -FU

    7001

    1310

    003

    W2

    EGP100 transducer for di� erential pressure

    Type EGP100F301 EGP100F401

    Power supply 24 V ~/= 24 V ~/=

    Measuring range 0...150 Pa 0...300 Pa

    Power consumption 24 V ~ 24 V =

    1.0 VA0.4 W

    1.0 VA0.4 W

    Parts in contact with media PC/ABS blend, MQ, CuSn6, FR4 PC/ABS blend, MQ, CuSn6, FR4

    Output signal 0...10 V, load > 10 Ωk 0...10 V, load > 10 Ωk

    Time constant, variable 0.05...2 sec. 0.05...2 sec.

    Positional infl uence ± 1% FS 150 Pa ± 0.75% FS 300 Pa

    Reproducibility 0.2% FS 0.2% FS

    Non-linearity 1% FS pressure-linear 1% FS pressure-linear

    Zero point stability < 0.3% FS < 0.3% FS

    Ambient temperature 0...60 °C 0...60 °C

    Type of protection IP 65 IP 65