Save Time and Moneywhen you need to exchange your old gyrocompass
Model SR03-01Mk2When replacing your old gyrocompass,
add SR03-01Mk2 and there is no need to buy new repeaters,reconfigure or replace ARPA Radars, Autopilots, etc.
In addition you will save time on installation and cabling.
www.ScanRepeater.com e-mail: [email protected]
Fort Lauderdale, FL - USA • Kolbotn (Oslo) - Norway
SCANDINAVIAN MICRO SYSTEMSKOLBOTN FORT - NORWAY
FORT LAUDERDALE, FLORIDA- USAwww.scansys.no e-mail: [email protected]
PROJECT: DRAWING TITLE AND DESCRIPTION: DRAWING No:
Max 12
Mechanical
Repeaters
SR03-01Mk2
NMEA Heading
Mechanical Repeaters
Step-by-Step or
Synchro
Step or Synchro
interface for
Autopilot, Radars,
etc...
NMEA Heading
REMOVE !!
Remove the OLD Gyro
Signals:
SR03-03
SR01-02
OPTIONAL:
SR03-03 Remote Control Unit
in Bridge Consol
Remote Control
Communication
Synchro or..
Step-by-Step System
REPLACE OLD
Gyrocompass
Use EXISTING
Repeater Distribution Unit
to Existing Repeaters
(New Distribution Unit
availble on Request
.. ask for SR03-04)
Alarm Relay
Output
Alarm System on Bridge
OPTIONAL:
SR01-02 Digital Repeater in
Steering Gear Room
OPTIONAL:
SR01-02 Digital Repeater
Conning / Bridge
New Gyrocompass
11
SR03-01Mk2 Universal NMEAto Step or Synchro ConverterTypical Retrofit Configuration
Single Gyro Replacement with one Universal ConverterKeep Existing Distribution Unit
SCANDINAVIAN MICRO SYSTEMSKOLBOTN FORT - NORWAY
FORT LAUDERDALE, FLORIDA- USAwww.scansys.no e-mail: [email protected]
PROJECT: DRAWING TITLE AND DESCRIPTION: DRAWING No:
Max 12
Mechanical
Repeaters
SR03-01Mk2
NMEA Heading
Mechanical Repeaters
Step-by-Step or
Synchro
Step or Synchro
interface for
Autopilot, Radars,
etc...
NMEA Heading
SR03-03
SR01-02
OPTIONAL:
SR03-03 Remote Control Unit
in Bridge Consol
Remote Control
Communication
EXISTING Synchro or..
Step-by-Step signals
KEEP the OLD
Gyrocompass
Use EXISTING Repeater
Distribution Unit
(New Distribution Unit
availble on Request
.. ask for SR03-04)
Alarm Relay
Output
Alarm System on Bridge
OPTIONAL:
SR01-02 Digital Repeater in
Steering Gear Room
OPTIONAL:
SR01-02 Digital Repeater
Conning / Bridge
New Gyrocompass
11
SR03-05
Mechnical Switch-Over
1 2
0 = ISOLATED Position
0
SR03-01Mk2 Universal NMEAto Step or Synchro ConverterTypical Retrofit Configuration
DUAL Gyro System w/Heading Monitoring Functionone New Gyrocompasses,m one New Uiversal Converter:Keep the Old Gyrocompass with Mecahnical Swith/Over
SCANDINAVIAN MICRO SYSTEMSKOLBOTN FORT - NORWAY
FORT LAUDERDALE, FLORIDA- USAwww.scansys.no e-mail: [email protected]
PROJECT: DRAWING TITLE AND DESCRIPTION: DRAWING No:
11
Max 12
Mechanical
Repeaters
NMEA Heading #1
OPTIONAL
SR03-03 Remote Control Unit
w/ Compass Compare &
HEADING MONITOR Alarm
NMEA Heading
SR03-03
SR01-02
NMEA Heading #2
SR03-01Mk2
w/ Heading Monitor Function
REMOVE
Remove OLD Gyro Signals
Existing Repeater
Distribution Unit for
Step-by-Step or..
Synchro Repeaters
(New Distribution Unit
availble on Request
.. ask for SR03-04)
REPLACE OLD
Gyrocompass
Remote Control
Communication
Alarm Relay Output
Mechanical Repeaters
Step-by-Step or
Synchro
Step or Synchro
interface for
Autopilot, Radars,
etc...
Alarm System on Bridge
OPTIONAL:
SR01-02 Digital Repeater in
Steering Gear Room
OPTIONAL:
SR01-02 Digital Repeater
Conning / Bridge
New Gyro
Gyro # 1
SATELLITE Compass
as BACK-UP
Compass # 2
SR03-01Mk2 Universal NMEAto Step or Synchro ConverterTypical Retrofit Configuration
DUAL Gyro System w/Heading Monitoring FunctionGyrocompasses with Satellite Compass as BACK-Up
with one Universal Converter
SCANDINAVIAN MICRO SYSTEMSKOLBOTN FORT - NORWAY
FORT LAUDERDALE, FLORIDA- USAwww.scansys.no e-mail: [email protected]
PROJECT: DRAWING TITLE AND DESCRIPTION: DRAWING No:
11
Max 12
Mechanical
Repeaters
NMEA Heading #2
OPTIONAL
SR03-03 Remote Control Unit
w/ Compass Compare &
HEADING MONITOR Alarm
Selected
NMEA Heading
SR03-03
Tokimec or Yokogawa
Autpilot
NMEA Heading #1
SR03-01Mk2
w/ Heading Monitor Function
Existing Repeater
Distribution Unit for
Step-by-Step or..
Synchro Repeaters
(New Distribution Unit
availble on Request
.. ask for SR03-04)
Remote Control
Communication
Alarm Relay Output
Mechanical Repeaters
Step-by-Step or
Synchro
Step or Synchro
interface for
Autopilot, Radars,
etc...
Alarm System on Bridge
OPTIONAL:
SR01-02 Digital Repeater in
Steering Gear Room
Tokimec (Step) or
Yokogawa (Synchro?)
Gyro # 1
SATELLITE Compass
as BACK-UP
Compass # 2
SR03-01Mk2 Universal NMEAto Step or Synchro ConverterTypical Retrofit Configuration
DUAL Gyro System w/Heading Monitoring Function driving old Repeaters andSpecial Autopilot interface. Existing Gyrocompasses with Satellite Compass
as BACK-Up. - one Universal Converter -
Use SR01-40 for:
6-Step/Micro-Step or
360X/90X Synhcro
SR03-01Mk2 can be set to ouput specialserial data protocols for:
Yokogawa: $HCHDT,,T*hhCRLF or...Tokimec: STX K xxx.x L xx.x ETX
ROT is computed by SR03-01Mk2
SCANDINAVIAN MICRO SYSTEMSKOLBOTN FORT - NORWAY
FORT LAUDERDALE, FLORIDA- USAwww.scansys.no e-mail: [email protected]
PROJECT: DRAWING TITLE AND DESCRIPTION: DRAWING No:
11
Max 12
Mechanical
Repeaters
NMEA Heading #1
OPTIONAL
SR03-03 Remote Control Unit
w/ Compass Compare &
HEADING MONITOR Alarm
NMEA Heading
SR03-03
SR01-02
NMEA Heading #2
SR03-01Mk2
w/ Heading Monitor Function
REMOVE
Remove OLD Gyro Signals
Existing Repeater
Distribution Unit for
Step-by-Step or..
Synchro Repeaters
(New Distribution Unit
availble on Request
.. ask for SR03-04)
REPLACE OLD
Gyrocompass
Remote Control
Communication
Alarm Relay Output
Mechanical Repeaters
Step-by-Step or
Synchro
Step or Synchro
interface for
Autopilot, Radars,
etc...
Alarm System on Bridge
OPTIONAL:
SR01-02 Digital Repeater in
Steering Gear Room
OPTIONAL:
SR01-02 Digital Repeater
Conning / Bridge
New Gyro
Gyro # 1
New Gyro
Gyro # 2
SR03-01Mk2 Universal NMEAto Step or Synchro ConverterTypical Retrofit Configuration
DUAL Gyro System w/Heading Monitoring Functiontwo New Gyrocompasses and one Universal Converter
SCANDINAVIAN MICRO SYSTEMSKOLBOTN FORT - NORWAY
FORT LAUDERDALE, FLORIDA- USAwww.scansys.no e-mail: [email protected]
PROJECT: DRAWING TITLE AND DESCRIPTION: DRAWING No:
SR03-01Mk2 Universal NMEAto Step or Synchro ConverterTypical Retrofit Configuration
11
HEAD
IN
G #
1 (N
MEA)
HEAD
IN
G #
2 (N
MEA)
New Gyro as
GYRO #1
Old GYRO as #2
SR03-01Mk2-#1
Unicersal NMEA to STEP or
SYNCHRO Converter
SR03-06
Secure 24V DC
Power System
Dual Converters w/
Battery Back-Up
NM
EA
H
dn
g O
UT #
1
Rem
ote C
trl #
1
MAIN
O
UTPU
T
STEP or SYN
CH
RO
SR03-05D
Dual System Mechnical Switch-Over
Unit w/ NMEA buffers
ALA
RM
C
on
vrt #
1
Remote Control
Communication
SR03-03
in Bridge Console
Remote Control Unit with
COMPASS COMPARE,
HEADING MONITOR Alarm and
SWITCH-OVER function
between Gyro #1 and Gyro #2
SR03-03 Optional
one - or many SR01-02
Heading & ROT
RepeatersNMEA Heading Distribution
(Source is the selected Master Compass)
Alarm Relay Output
To ALARM System
GPS
Input for Speed &
Latitude Correction
Multiple Other NMEA users..
Step
o
r S
yn
ch
ro
S
ig
nal
fo
r d
rivin
g M
ech
nical R
ep
eaters
an
d o
th
er o
ld
typ
e In
terfaces
Other
Step or Synchro
users..
Mechical Repeaters
(up to 6 units)
ALARM
Gyro#1
ALARM
Gyro#2
24V DC
NMEA
GPS
MAIN
O
UTPU
T
STEP or SYN
CH
RO
NM
EA
H
dn
g O
UT #
2
Rem
ote C
trl #
2
ALA
RM
C
on
vrt #
2
SR03-01Mk2-#2
Unicersal NMEA to STEP or
SYNCHRO Converter
Gyro & Converter Alarm OUTPUT
Relay output; NO/BC & COM
1 2
0 = ISOLATED Position
0
SR01-02
MAINS SUPPLY:
110V or 220V AC
50
60
Hz
SR03-04 (6 repeaters)
Fused Step/Synchro Distribution Unit
(can also be EXISTING Distr. Unit)
MAIN OUTPUT
STEP or SYNCHRO
24V DC
HDNG
Gyro#1
HDNG
Gyro#2
HDNG
Gyro#1
HDNG
Gyro#2
INPUT from
SR03-01
All Output Signals are fused:
Fuse Type: 2A, 250VAC "Slow" 5mm Glass Fuse
6-Step or Micro Step,
360X, or 90X, 36X, 1X Synchro
Use SR01-40 for:
6-Step/Micro-Step or 360X/90X Synhcro
Use: SR01-60 for:
1X, 2X ,11X, 36X Synchro
NMEA
Gyro#2
24V DC
DUAL REDUNDANT Gyro System w/Heading Monitoring FunctionTwo Gyrocompasses & two Universal Conveerter
One New Gyro and one Old Gyro (ready for 2nd New Gyro)
SCANDINAVIAN MICRO SYSTEMSKOLBOTN FORT - NORWAY
FORT LAUDERDALE, FLORIDA- USAwww.scansys.no e-mail: [email protected]
PROJECT: DRAWING TITLE AND DESCRIPTION: DRAWING No:
11
HEA
DIN
G #
1 (N
MEA
)
HEA
DIN
G #
2 (N
MEA
)
GYRO #1
GYRO #2
SR03-01Mk2-#1
Unicersal NMEA to STEP
or SYNCHRO Converter
SR03-06
Secure 24V DC
Power System
Dual Converters w/
Battery Back-Up
Note:
Gyrocompasses Shown are
Raytheon Anschütz STD22
NM
EA
H
dn
g O
UT #
1
Rem
ote C
trl #
1
MA
IN
O
UTP
UT
STEP
o
r S
YN
CH
RO
SR03-05D
Dual System Mechnical Switch-Over
Unit w/ NMEA buffers
ALA
RM
C
on
vrt #
1
Remote Control
Communication
SR03-03
in Bridge Console
Remote Control Unit with
COMPASS COMPARE,
HEADING MONITOR Alarm and
SWITCH-OVER function
between Gyro #1 and Gyro #2
SR03-03
one - or many SR01-02
Heading & ROT
RepeatersNMEA Heading Distribution
(Source is the selected Master Compass)
GPS
Input for Speed &
Latitude Correction
Multiple Other NMEA users..
Step
o
r S
yn
ch
ro
S
ig
nal
fo
r d
rivin
g M
ech
nical R
ep
eaters
an
d o
th
er o
ld
typ
e In
terfaces
Other
Step or Synchro
users..
Mechical Repeaters
(up to 6 units)
ALARM
Gyro#1
ALARM
Gyro#2
24V DC
NMEA
GPS
MA
IN
O
UTP
UT
STEP
o
r S
YN
CH
RO
NM
EA
H
dn
g O
UT #
2
Rem
ote C
trl #
2
ALA
RM
C
on
vrt #
2
SR03-01Mk2-#2
Unicersal NMEA to STEP
or SYNCHRO Converter
Gyro & Converter Alarm OUTPUT
Relay output; NO/BC & COM
1 2
0 = ISOLATED Position
0
SR01-02
MAINS SUPPLY:
110V or 220V AC
50
60
Hz
SR03-04 (6 repeaters)
Fused Step/Synchro Distribution Unit
(can also be EXISTING Distr. Unit)
MAIN OUTPUT
STEP or SYNCHRO
24V DC
HDNG
Gyro#1
HDNG
Gyro#2
HDNG
Gyro#1
HDNG
Gyro#2
INPUT from
SR03-01
All Output Signals are fused:
Fuse Type: 2A, 250VAC "Slow" 5mm Glass Fuse
SR03-01Mk2 Universal NMEAto Step or Synchro ConverterTypical Retrofit Configuration
DUAL REDUNDANT Gyro System w/Heading Monitoring FunctionTwo Gyrocompasses + two Universal Converters & Mechical Swithcover
+ Redundant 24V Power Systems