ElectroFlow is an integrated power conditioning system. It reliably performs the following functions:
• Enhances power quality throughout the entire facility• Protects equipment and increases longevity• Reduces downtime and maintenance
By improving power quality, ElectroFlow reduces electrical consumption in kW, kWh & kVA.
• From 2% to 30%, dependent upon electrical rates and conditions
We provide guaranteed savings!
Savings Through Power Quality
Technical description
ElectroFlow consists of multi-stage LRC tank circuits (inductive-resistive-capacitive),
of each application. The system will operate in the following modes:
• 208V to 345kV• 50 or 60Hz• Three-phase application• • Typically installed in parallel• Equipped with a microprocessor
based regulator, if required, which monitors Voltage (V), current (I), power factor (PF) and harmonics (Hr), at a rate of 3840-15360 samples per second.
Application
Several conditions may justify the acquisition of an ElectroFlow system:
• Corporate energy savings targets•
issues• Process sensitivity to Power Quality
(nuisance tripping, blown components)• Corporate environmental targets (Kyoto
or other)
ElectroFlow applies to any industrial, institutional or commercial facility where demand exceeds 100 kW:
Industrial – Automotive, Steel, Cement, Chemical, Printing, Machine Shops, Furniture Manufacturing, Welding, Plastic, Pharmaceutical, Sawmills, etc.Institutional – Pumping Stations, Water Treatment, Hospitals, Universities, Military Bases, etc.Commercial – Dairy, Food Processing, Refrigerated Storage, etc.
Basic system
The basic ElectroFlow system solves common issues linked to power quality. ElectroFlow will:
1. Improve and stabilize voltage
2. Enhance three-phase balancing
3. Protect against surges and transients (up to 300 000 V)
4. Filter broadband harmonics (IEEE 519 Standard)
5. Improve power factor ( +/- 95%) (with no capacitor side e ects)
6. Free up KVA capacity
Options
The ElectroFlow system can be equipped to provide:
7. Protection against brownouts and voltage sags
8. Protection against intermittent supply failure (up to 1 second in duration)
9. Spe
V I
I
Harmonics
Am
plit
ude
Time
Fundamentalh3h5h7
sum
Complete Analysis
We o er a complete and comprehensive electrical analysis of your current situation and
Warranty
savings.
System components carry an OEM one-year repair/replacement warranty. Optional extended warranty is also available.
Fail Safe
Should any of the ElectroFlow units fail for any reason, it will isolate itself from the circuit and will not disrupt the customer’s normal operation.
Authorized Distributor
EnerFlow Solutions Inc.St-Hubert (Quebec) Canada J3Y 8Y5
In Canada : 1.877.926.6885International : (001) 450.926.6885
ElectroFlow Savings Through Power Quality
M a n u f a c t u r e d b y E l e c t r o F l o w I n c .
ElectroFlow Inc.545 Curé-Boivin Blvd. BoisbriandJ7G 2A8, (QC) Canada
450-818-6885
ElectroFlow Inc.545 Curé-Boivin Blvd.Boisbriand (QC)J7G 2A8Canada
450-818-6885