SC3050 Nov ‘12 - 1 - If you require assistance, please contact your local DV Systems Distributor or Authorized Service center. You may contact the manufacturer directly as follows: Phone: (705) 728-5657 Web: www.dvsystems.ca Fax: (705) 728-4974 Email: [email protected] SC30, SC40 & SC50 Rotary Screw Air Compressor Units - - - Installation Maintenance And Service Data Quick Start ……………............................................. 2 Safety Precautions …………………………………… 4 Unpacking and Inspection …………………………... 5 Installation – Mechanical ……………………………. 6 Lubrication ……………………………………………. 8 Installation – Electrical ………………………………. 9 Start-up Procedures …………………………………. 12 Preventative Maintenance Schedule ………………. 13 Maintenance Procedures ……………………………. 15 ‘CSC200’ Controller ………………………..………… 20 Sequencing with ‘CSC200’ Controller ……………… 29 Separator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting Guide ……………………………… 33 Warranty ……………………………………………….. 36 Please read this manual before installing or using your Air Compressor Unit. It contains valuable information that will help in the receiving, installation, use, and maintenance of the Unit. Please keep this manual in a safe place for future reference. All of the information, policies, and procedures in this reference manual apply exclusively to DV Systems.
Transcript
Page 1: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 1 -

If you require assistance, please contact your local DV Systems Distributor or Authorized Service center. You may contact the manufacturer directly as follows:

Phone: (705) 728-5657 Web: www.dvsystems.ca Fax: (705) 728-4974 Email: [email protected]

SC30, SC40 & SC50

Rotary Screw Air Compressor

Units - - -

Installation Maintenance

And Service Data

Quick Start ……………............................................. 2 Safety Precautions …………………………………… 4 Unpacking and Inspection …………………………... 5 Installation – Mechanical ……………………………. 6 Lubrication ……………………………………………. 8 Installation – Electrical ………………………………. 9 Start-up Procedures …………………………………. 12 Preventative Maintenance Schedule ………………. 13 Maintenance Procedures ……………………………. 15 ‘CSC200’ Controller ………………………..………… 20 Sequencing with ‘CSC200’ Controller ……………… 29 Separator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting Guide ……………………………… 33 Warranty ……………………………………………….. 36

Please read this manual before

installing or using your Air Compressor Unit. It contains valuable information that will

help in the receiving, installation, use, and

maintenance of the Unit.

Please keep this manual in a safe place for future reference.

All of the information, policies, and

procedures in this reference manual apply exclusively to DV Systems.

Page 2: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 2 -

24”

60”

24”

24”

Quick Start Mechanical Installation. (Refer to Page 6)

Lubrication. Rotation. (Refer to Page 8) (Refer to Page 10)

‘A’

‘B’

Correct Oil Level

Before starting the Unit for the first time, ensure there is oil in the Reservoir.

The oil level should be A) slightly below the Metal Band as shown or B) close to the center of the Oil Sight Glass, both while at rest.

Check the oil level after the Unit has been at rest for a minimum of 30 minutes.

If so equipped, the Gauge (‘A’) is located on the side of the Reservoir, not shown from this angle.

The Unit should be located in a dry, clean, cool, dust free, and well ventilated area.

Allow a minimum 24” around and 60” above Unit.

The ambient temperature should be between 10°C and

40°C (50°F and 104°F).

Ensure that the floor under the Unit is smooth, level and capable of bearing the weight of the Compressor.

If installed in a compressor room, ensure that the room is

adequately ventilated

The Unit is equipped with an ‘Anti Rotation’ Switch. This stops the Unit from operating in the wrong direction and causing irreparable damage.

An ‘E:0020 Anti Rotation’ Error will appear

on the Controller Screen if the rotation is incorrect. If this occurs, simply change ‘L1’ and ‘L3’ at the Control Panel.

Reservoir

Page 3: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 3 -

Quick Start (cont’d)

Unit Operation. Shown below is the ‘CSC200’ Controller which regulates the operation of the Unit. It is used to start and stop the Unit, and it provides information as to system pressure, temperature, etc. Starting the Unit: Press the ‘Start’ Button. Stopping the Unit: Press the ‘Stop’ Button Note:

1. Do not stop the Unit using the ‘Emergency Stop’ Button unless there is a danger to the product or of personnel injury.

2. Do not stop the Unit by use of a disconnect or breaker.

Please refer to Page 20 to 28 for a more detailed description of the ‘CSC200’ Controller.

Using the Emergency Stop Button, disconnect, or breaker to stop the Unit will not allow the Unit to go through an unloading sequence, and could result in damage to the Motor, Starter, or other electrical components. Damage caused in this manner is not covered by the manufacturers Warranty.

Stop. Causes the Unit to enter ‘Idle’ mode and then shut off.

Start. Starts the Unit.

Digital Readout. Indicates Unit pressure, temperature, etc.

Emergency Stop. Will quickly shut the Unit off. It is only to be used in an emergency.

Page 4: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 4 -

Safety Precautions In order to operate the Compressor Unit safely and correctly, we have opted to use the following symbols to make you aware of important points. These points relate to user safety and preventing equipment problems. Please pay close attention to these sections.

The following hazards may occur during the normal use

of the equipment. Please read the following chart.

Area: Hazard: Safeguards:

What may occur if precautions are notobserved.

Tampering with the Unit while under Relieve all pressure from the Unitfull or partial pressure may cause an before attempting any repair orexplosion. maintenance work.

As the Unit starts and stops Shut off all power to the Unit beforeautomatically, serious injury may attempting to repair or maintainresult from working on the Compressor the Compressor.with the power still in the 'on' position.As the Unit starts and stops Shut off all power to the Unit beforeautomatically, do not come into attempting to repair or maintaincontact with moving parts. the Compressor.

Air compressed by the Unit is not Never breath untreated compressedsuitable for inhaling. It may contain air produced by the Compressor.vapours harmful to your health.

Compressor Air End, Motor, and Never touch the Air End, Motor, orTubing become hot when running. Tubing during or immediately afterTouching these areas may cause operation.serious burns.As the electrical components on the Do not install in hazardous locations.Compressor are General Purpose, The Compressor must be a minimumthere is a potential for explosion, should of 20 feet (6.1 meters) from any sourcevapours be present in the area. of potentially explosive vapours.

What to look for. How to avoid the hazard.

2 0 F T6 . 1 m

Important safety Information. A hazard that may cause serious injury or loss of life.

Important information that indicates how to prevent damage to equipment, or how to avoid a situation that may cause minor injury.

Information that you should pay special attention to.

Page 5: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 5 -

Unpacking and Inspection

It is the responsibility of the receiver of the goods, either the Distributor or Customer, to ensure that the product has been shipped in full, and has arrived in suitable condition. Damage to the product may not be visible at time of off-loading, but may only become apparent upon unpacking or start-up. Some areas to initially check are as follows: a) Check for damage to the crating and/or packaging. b) Check the exterior of the Cabinet for damage, either cosmetic or mechanical. c) If there is mechanical damage, open the Cabinet to determine whether there is any internal damage to the Unit. Should there be damage to the product or shortages in shipment: 1) Stop any further unpacking or operation of the product. 2) Make note of the problem on the Freight Bill, should it concern a shortage or visible damage to the product. 3) Should the damage be noticed only after the product has been received, contact the transport company immediately to file a claim. Depending on the problem, it may be wise to photograph the damage. Also, it may be wise to discuss with the carrier representative the time allotted to give notice of loss or damage to the product; there may be guidelines which limit timeframes of same. 4) Do not attempt further unpacking or operation of the product. Also, do not discard any packing material used. 5) A Loss or Damage Claim must be submitted to the carrier and supported by the following documents: - Copy of Freight Bill of Lading - Copy of the Invoice and Estimate to repair, in case of damage - Damage Report - Copy of photos, if applicable

Each DV Systems Air Compressor is carefully tested and inspected before shipment. Though every attempt is made to ensure the safe and complete shipment of our product, freight damage or misplacement of goods may occur. Shipments of DV Systems products are the property of the Consignee when the products leave our facility. DV Systems Inc. is not responsible for any damages or shortages caused to the product after it has left our shipping dock.

Page 6: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 6 -

The Compressor must not be operated in a confined area where the heat from the Unit cannot readily escape.

Installation – Mechanical

Moving of the Unit.

When moving the Air Compressor, the forklift or hand lift forks go under the Unit from the directions as indicated. Please be advised that care must be taken when moving and positioning the Units as they are top heavy.

Location of the Unit.

Items to consider when installing the Unit are as follows:

The Unit should be located in a dry, clean, cool, dust free, and well ventilated area. If possible, the Compressor should be located in a separate room or area, away from the general operations of the shop.

Allow a minimum of 24” around and 5 feet above

the Unit for easy access to the various sides, this being for both the proper ventilation of the Unit and ease of servicing.

Ensure that the floor under the Unit is smooth,

level and capable of bearing the weight of the Compressor. The Compressor must sit squarely on the floor.

If installed in a compressor room, ensure that the

room is adequately ventilated. (One Horsepower produces approximately 2500 BTU/HR.) See Page 7.

The ambient temperature should be between

50°F and 104°F (10°C to 40°C).

If installing the Unit on a mezzanine, ensure that the structure can safely support the weight of the Unit. As well, the sound level of the Unit may increase due to the harmonics created by the structure; use Vibration Pads to lessen this.

Many common Compressor problems can be attributed to the location or installation of the Unit. Make sure the Unit is in a suitable location, and installed correctly.

Page 7: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 7 -

Installation – Mechanical (cont’d) Shown below and on the following page are items which assist in making a good installation. These are both intake and exhaust ductwork, helping the Unit to a) draw in clean outside air and b) exhaust the warmer air away from the Unit. The warmer air may be used, with the inclusion of a damper in the exhaust ducting, to warm the interior of the building during the colder months of the year.

Page 8: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 8 -

Lubrication

Oil Fill Port

Oil Drain Valve

Initial Start-up. Each Compressor Unit built is extensively tested at the factory before shipment. The Unit is shipped with the original oil in it as used for testing purposes. Check the Oil level and for any Oil leaks on a daily basis. This must be done when the Unit is off. Top up the Oil level on a monthly basis. Use only DV Systems ‘DEV-3000’ Synthetic Oil. Also, do not mix the ‘DEV-3000’ with any other lubricant. Subsequent Oil Changes. Drain the existing oil from the Unit. (Please be advised that the Unit cannot be drained fully of oil, as some oil may remain in various components ie Cooler, Tubing, etc.) Fill the Oil Reservoir to A) the Metal Band on the External Oil Level Gauge or B) the center of the Sight Glass, as shown below. Do not under or overfill. Use only DV Systems ‘DEV-3000’ Synthetic Oil, available in both 1 US gallon (3.8 litre) jugs or 5 US gallon (5 x 3.8 litre) pails. Any remaining oil may be used for ‘top-ups’.‘ The ‘MK-SC30-50-3’ Maintenance Kit includes:

(5) US Gallon (5 x 3.8 litre) Oil (‘DEV-3000’) (2) Oil Filter (’DSC-624’) (1) Air/Oil Separator Filter (’DSC-151’) (2) Air Filter (’DSC-606’) (1) In Line Filter (‘DSC-612)

The ‘MK-SC30-50-3’ Kit is appropriate for Units with the suffix ‘-03’ and ‘-04’. Example: SC50-04-69

Do not attempt to operate the Unit without first checking whether there is oil in the Oil Reservoir. Add oil as required. Serious damage may result from use, however limited, without oil.

Use of improper oil may negatively affect Compressor performance or shorten Unit life. Resulting problems are not covered by the DV Systems Inc. Air Compressor Warranty.

Condensation (water) may form in the Oil Reservoir with the oil. If this occurs, as the water will tend to settle on the bottom of the Reservoir, drain the water from the Reservoir until you notice oil draining. Top up the Reservoir with new oil using only the DV Systems ‘DEV-3000’ oil.

External Oil Level Gauge showing proper oil level when Unit is off

When running, oil level will be closer to bottom Elbow

Oil Reservoir

Correct Oil Level

‘A’

‘B’

Page 9: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 9 -

Installation - Electrical When making power and control wiring connections, please observe the following precautions:

Ensure that all wiring, fusing, etc is done in a manner that meets with the appropriate codes and regulations.

See the sales drawings and electrical schematic contained in this manual for information about Motor nameplate amps, this used to determine the appropriate Disconnect / Breaker and Wiring sizes.

General Information.

It is your responsibility to ensure that the Compressor Unit is electrically connected in a safe and correct manner. Any electrical work should be carried out by a competent Electrician, and be done in such a way that it meets all applicable Codes and Regulations. Ensure that a suitable Fused Disconnect or Breaker (by others than DV Systems) is installed in the electrical supply before the Compressor Unit.

The sales drawing found at the back of this booklet indicates the amp rating for the Unit. This information is required in sizing a Disconnect, Fuses, and/or a suitable Breaker. As well, an electrical schematic is enclosed for reference. Electrical wiring and conduit from the building supply, through the Compressor Cabinet, and to the Switch in the Compressor Control Panel, must be rated for 110°C or higher.

Failure to observe any of the above precautions could result in severe personal injury or death, and/or damage to the Unit.

Failure to correctly connect the Compressor to your building's electrical services may result in serious personal injury or damage to the equipment.

Install all covers and panels before

applying power to the Unit.

Before servicing the Unit, ensure the power source has been shut down and locked off.

Read and understand the information

contained in this manual before installing or operating the Unit.

Wiring Practices.

Page 10: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 10 -

Installation – Electrical (cont’d) Wiring must be done in a manner that the full Motor nameplate voltage +/- 10% is available at the Motor terminals during start-up. Contact your local Distributor or Service Centre if additional information is needed. The Warranty that exists on the Electric Motor is that of the original manufacturer. In the event of a Motor failure, contact your DV Systems Distributor or Service Centre for the location of the nearest authorized Motor Service Centre. It is critical that the Motor and Air End in the Rotary Screw Unit be turning in the correct manner. Irreparable damage will be done if the Unit rotates in the opposite direction. The Unit is equipped with an ‘Anti Rotation Switch’ which allows the Unit only to operate in the correct direction. If the following error is visible on the Screen and the Unit will not start, simply switch power leads L1 and L3.

E:0020 Anti Rotation

Switching the leads will allow the Unit to operate as designed. Press the ‘Reset’ key on the Controller.

The Electrician is to bring power to the Unit at the Electrical Panel accessible by means of opening the Unit Front Panel as shown at right. Refer to the enclosed sales drawing and electrical schematic in determining the correct Disconnect / Breaker and Wire size.

Do not attempt to operate the Unit without first checking whether there is oil in the Oil Reservoir. Add oil as required. Serious damage may result from use, however limited, without oil.

Electrical Connection.

Motors. Motors.

Motor/Air End Rotation.

Bring power to L1, L2, L3

Page 11: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 11 -

AC Motor Maintenance Instructions

Cleaning. To ensure that the Motor operates at optimum temperatures and provides years of trouble-free service, periodically clean the outside of the Motor Housing of any build-up of dust, etc. Though it is not anticipated that, if installed correctly and in a suitable environment, there should be much build-up on the Motor, keeping the Housing clean will allow the Motor to operate more efficiently. Lubrication. This is a ball bearing motor. The bearings have been lubricated at the factory. Motors that do not have regrease capability are factory lubricated for the normal life of the bearings. Noted below is a chart outlining the interval at which the Motor should be lubricated, this based on the Motor horsepower. This must be part of a regular maintenance schedule.

Interval Weight of Grease Volume of Grease Motor HP

in Hours Ounces Grams Cubic Inch Teaspoon 30 2,200 0.81 23.1 1.5 5.2 40 2,200 0.81 23.1 1.5 5.2 50 2,200 0.81 23.1 1.5 5.2

The above chart is based on a standard environment in which the Motor is operating of 40°C. For other conditions, please multiply the Hour Interval from the chart above by the factor as indicated below.

Severity of Duty Factor Environmental Conditions Standard 1.0 40°C, clean, little corrosion Severe 0.5 50°C, moderate dirt, corrosion Extreme 0.1 > 50°C, severe dirt, abrasive dust Low Temperature 1.0 < 30°C

Lubricant. Baldor motors are pre-greased, normally with Chevron SR #1-2. Equivalent and compatible greases are Texaco Polystar, Shell Dolium R and Amoco Rykon Premium #2.

Page 12: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 12 -

Do not attempt to operate the Unit without first checking whether there is oil in the Oil Reservoir. Add oil as required. Serious damage may result from use, however limited, without oil.

Initial Start-up 1) Remove the LH Side Access Panel, and ensure

that there is sufficient Oil in the Oil Reservoir. Refer to the ‘Lubrication’ section (page 8) in this manual for proper type and level of Oil.

2) Do a visual inspection of the Unit, and ensure

that all fasteners are sufficiently tightened. This must be done, as some fasteners may become loose in transit.

Start-up Procedures

Do not place any materials in close proximity to the Compressor. Placing materials against or close to the Unit will limit the cooling required, and could lead to premature failure.

Shut off all power to the Compressor Unit before attempting any repair or maintenance.

Adjusting the settings of the Controller could adversely affect the performance of the Unit. Only those individuals with knowledge of the Unit should make any adjustments.

Unit Controls

Start Button Allows the Unit to start. Stop Button

Use this to shut the Unit off. Allows the Unit to idle and then stop after several seconds.

Emergency Stop Button Do not use to normally stop the Unit. To be used to stop the Unit in emergencies only. Normal use will damage electrical controls and Shaft Seal.

3) Place the Fused Disconnect / Breaker in the ‘On’ Position. Check that there is power to the Controller.

4) During normal operation of the Unit, keep the

Access Panels closed at all times. 5) Ensure the Ball Valve from the Unit is closed,

press the ‘Start’ Button, and run the Unit up to maximum pressure. The Unit will run up to approx. 120 psi, at which point the Motor will continue to run but not compress air.

6) Once the Unit reaches 120 psi, it will idle for 10

minutes (30 HP) or 16 minutes (40 & 50 HP) and shut off.

7) Open the Ball Valve slightly and allow the air to

bleed from the Tank. Once the pressure reaches approx 100 psi, the Unit will start and begin to compress air after a short delay.

8) Measure the amp draw as the Unit reaches

maximum pressure. 9) Close the Ball Valve, allow the Unit to reach

maximum pressure, idle, and shut off. Once off, check the various fittings etc inside the Cabinet to ensure there are no internal leaks.

10) Once you are confident that there are no internal

leaks, the Unit will be ready for normal use.

Page 13: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 13 -

Preventative Maintenance Schedule Noted on the following pages are general Maintenance guidelines based on average working conditions. Should the Unit be worked under extreme conditions, please contact your DV Systems Distributor for further input. As well, all maintenance/service work must be carried out by a qualified Technician. The typical operating temperature of the Unit, this dependent on ambient temperatures, is between 70°C and 85°C. If the operating temperature of the Unit is too low (less than 70°C):

condensation will build up in the system and mix with the oil, causing internal component problems in the Unit

Change the ambient conditions to increase the operating temperature. If the operating temperature of the Unit is too high (above 85°C):

the oil will oxidize and lose it’s properties, this causing internal damage to components as well to combat this, the oil must be changed more often than noted below.

When servicing the Air Compressor, shut off all power to the Unit, and drain it of air pressure.

It is the responsibility of the Compressor owner to ensure that a regular Maintenance Schedule is followed.

Note: For Compressor Units used in an environment where the ambient temperature is above 90°F (32°C), the components marked with a ‘ # ’ (on the chart on the following page) must be changed more frequently.

Regular Maintenance Items. DV Systems offers a Maintenance Kit for your Unit, namely: MK-SC30-50-03 30 to 50 HP ‘SC Series’ Units (with suffix ‘-03’ and ‘-04’.) Each Kit consists of the following items, these suitable for approximately 4000 hours of operation. (1) DEV-3000 5 Gal. of Synthetic Oil (2) DSC-624 Oil Filter (1) DSC-151 Air/Oil Separator Filter (2) DSC-606 Air Filter (1) DSC-612 Inline Filter

Internal Access for Maintenance. The internal components of the Unit are accessible for servicing by way of removing the LH and RH Panels (‘A’)as shown. The Belt access is by way of the Front Panel (‘B’).

A

B

Page 14: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 14 -

Preventative Maintenance Schedule (cont’d)

Maintenance Interval (in 000’s of Hours) Maintenance Item: Daily

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

Compressor Room

Temperature Inspect Ambient Temperature should be between 10°C and 40°C (50°F and 104°F)

Cleanliness Inspect

Air Compressor Unit

Check Oil Level Inspect

Replace Oil # (See Note b) (1) X X X X X

Replace Oil Filter # (2) X X X X X X X X X X

Replace Air / Oil Separator # (3) X X X X X

Replace Air Intake Filter # (4) X X X X X X X X X X X X X X X X X X X X

Check Belt Tension X X X X X

Replace Belts X X X X X

Replace Tank Relief Valve X X X

Replace Solenoid (5) X X X X X

Rebuild Intake Valve (6) X X X X X

Rebuild Thermo Valve (7) X X X

Rebuild Minimum Pressure Valve (8) X X X X X

Replace Scavenge Line Filter (9) X X X X X

Motor Bearing Lubrication Refer to Motor Manufacturer’s Recommendations on Page 11

Notes: a) For Compressor Units used in an environment where the ambient temperature is above 90°F (32°C),

or b) where the Unit temperature runs regularly above 80°C (175°F), the components marked with a ‘#’ must be changed twice as often (example: in 4000 hours instead of 8000), and not as noted above.

b) The DV Systems Oil used in the Rotary Screw Units is rated as an 8000 hour Oil. A complete Oil change must be done every 8000 hours of Unit operation, or every 12 months, whichever occurs first. Please refer to the Warranty on Page 36 for further information.

c) If a component, during a regular inspection, has proven to be defective or unfit for regular operation, it must be repaired or replaced.

Parts and Repair Kits based on the above chart are as follows: (1) Oil: DEV-3000 (2) Oil Filter DSC-624 (3) Air / Oil Separator: DSC-151 (4) Air Intake Filter DSC-606 (5) 2 Way Solenoid DSC-162 (5) 3 Way Solenoid DSC-140 (6) Intake Valve Repair Kit DSC-176 (7) Thermo Valve Repair Kit: DSC-111-1 (8) Minimum Pressure Valve Kit: DSC-231 (9) Scavenge Line ‘In Line’ Filter DSC-612 As noted previously, the ‘MK-SC30-50-03’ Maintenance Kit (for Unit models having the suffix ‘-03’ and ‘-04’) includes the following items: (1) DEV-3000 5 Gal. of Synthetic Oil (2) DSC-624 Oil Filter (1) DSC-151 Air/Oil Separator Filter (2) DSC-606 Air Filter

(1) DSC-612 In-Line Filter

Page 15: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 15 -

Maintenance Procedures

Changing the Air Intake Filter. 1) Remove the Wing Nut and Washer from the

Assembly. 2) Remove the Canister Top, and remove the Air

Filter Element from the Canister. 3) Clean the Canister interior of any dust or build-

up. 4) Install a new Air Filter (DV Systems Part

Number ‘DSC-606’), ensure it fits snugly into the Canister, re-install the Canister Top, Washer, and Wing Nut.

Note: Depending on the quality of the air in the compressor room, it may be necessary to check and/or change the Air Filter more often than indicated on the 'Maintenance Schedule'.

Changing the Air / Oil Separator. 1) If necessary, use a strap wrench to

turn the original Separator counter-clockwise.

2) On the new ‘DSC-151’ Air / Oil Separator, lubricate the Separator Gasket with Compressor Oil.

3) Hand tighten the new Air / Oil Separator snug

Note: Do not over-tighten the Separator Filter on the Unit, as it may become very difficult to remove at a later date.

Changing the Oil Filter. The Oil Filter should be changed only after all of the oil has been drained from the Unit. 1. Ensure that you have a bucket and strap

wrench available. 2. Holding the bucket under the original Oil

Filter to capture any spillage, use the strap wrench to turn the Oil Filter counter-clockwise. The Oil Filter may still contain oil, so care must be taken.

3. On the replacement ‘DSC-624’ Oil Filter, lubricate the Filter Gasket with Compressor Oil.

4. Hand tighten the Oil Filter snug.

Page 16: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 16 -

Maintenance Procedures (cont’d)

‘A’

Correct Oil Level

Cleaning the Heat Exchanger. The circulation of air through the Heat Exchanger is critical to the correct operation of the Unit. Clean the Heat Exchanger on a regular basis. 1. Remove both Side Panels from the Unit. Access

will be as shown at right. 2. Vacuum the Heat Exchanger as necessary. Note: When cleaning the Heat Exchanger, do not use sharp objects or a wire brush. These items could damage the cooling coils.

Heat Exchanger

Oil Changes. Drain the existing oil by a) removing the Oil Drain Plug and b) opening the Oil Drain Valve. Please be advised that the Unit cannot be drained fully of oil, as some oil may remain in various components ie Cooler, Tubing, etc.) Once the oil is drained, close the Oil Drain Valve, and re-install the Oil Drain Plug. Fill the Oil Reservoir to A) the Metal Band on the External Oil Level Gauge or B) the center of the Sight Glass as indicated at right. (The Unit will be equipped with one or the other.) Do not under or overfill. Use only DV Systems ‘DEV-3000’ Synthetic Oil.

Oil Fill Port

Oil Drain Valve

Oil Reservoir

Gauge is located on side of Reservoir not shown from this angle.

Oil Drain Plug

‘B’

Page 17: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 17 -

Maintenance Procedures (cont’d)

Maximum Belt Tension Model Number: Unit HP:

Pressure: Hertz (New / Old)* Pound Force / Inch Deflection**

120 psig SC30-04 30

145 psig 51 / 45 17 lb / 0.6"

120 psig 55 / 48 17 lb / 0.55" SC40-04 40

145 psig 51 / 45 17 lb / 0.58" 120 psig 17 lb / 0.48"

SC50-04 50 145 psig

58 / 50 17 lb / 0.55"

Tensioning the Drive Belts. The tightening and loosening of the Drive Belts is done by way of moving the Motor Assembly vertically either towards or away from the Air End. To adjust the Belt tension, simply loosen and retighten the Adjusting Nuts as shown below.

Electric Motor

Belt Tensioning Assembly

Adjusting Nut

Notes: * Belt tension data for new Belts having run for approx. 10 hours. ** Pound Force and Inch Deflection figures are for new Belts only.

Page 18: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 18 -

Maintenance Procedures (cont’d)

To disassemble the existing Intake Valve Assembly: 1. Loosen and remove the (4) 8 mm Set Screw holding the Flange (#21) to the Assembly. Loosen each

Screw equally as the Flange is under tension. 2. Remove the Flange (#21) followed by the Bushing (#20), the Plate (#16), and the Spring (#14).

3. Using an arbour press, carefully compress the Piston Rod (#13). 4. Using snap ring pliers, remove the Lock Ring (#12) holding the Cover (#9) in place. 5. Slowly and carefully raise the Piston Rod (#13) by raising the arbour press. Do not release the pressure

off the arbour press if the Piston Rod (#13) is not moving upward out of the Housing (#2). If the Piston Rod is not moving but pressure is released by the press, the Spring (#3) will release the components at a high rate of speed.

6. Remove the Piston Rod (#13) and Spring (#3) from the assembly. 7. Clean the Housing, replace the components, and use light grease and oil to lubricate the components.

No. Description 1 O Ring # 2 Housing 3 Spring 4 Ring # 5 Piston Gasket # 6 Nut 7 Piston 8 O Ring # 9 Cover 10 O Ring #

No. Description 11 Bushing 12 Lock Ring 13 Piston Rod 14 Spring 15 Bushing 16 Plate 17 Gasket # 18 Ring # 19 O Ring # 20 Bushing 21 Flange

No. Description 1 O Ring # 2 Housing 3 Spring 4 Ring # 5 Piston Gasket # 6 Nut 7 Piston 8 O Ring # 9 Cover 10 O Ring #

Intake Valve Repair Kit. Shown below are the major components that make up the Intake Valve Assembly.

Changing the Scavenge Line ‘In-Line’ Filter. The ‘DSC-612’ In-Line Filter is located in the Scavenge Line between the Air-Oil Separator and the Air End, and removes any particles from the oil before it enters the Air End. The Filter must be replaced every 4000 hours to ensure the proper flow of oil through the Scavenge Line. When re-assembling the parts, use Loctite thread sealant. Do not use Teflon tape, as the tape could come loose and obstruct the passage of oil.

Intake Valve

In-Line Filter

Air End

Scavenge Line

2 3

4

5 6

7 9

11 13

14 16 18 20

8

10

12

15 17 19 21

Note: Items with the ‘#’ symbol are included in the ‘DSC-176’ Intake Valve Repair Kit.

Exercise extreme caution when continuing with the following steps. Serious injury may result from any errors.

Page 19: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 19 -

Maintenance Procedures (cont’d)

Repair Kit

Repair Kit

Thermo Valve Repair Kit. The Thermostatic Valve, or commonly called ‘Thermo Valve’, provides a means of re-directing the oil to be cooled. At start-up, the oil travels from the Oil Reservoir, through the Oil Filter, and into the Air End. As the oil temperature reaches approx. 71°C, the Thermo Valve re-directs the warm oil through the Heat Exchanger, allowing it to cool before entering the Oil Filter. It is imperative that the Heat Exchanger be kept clean, as a dirty Heat Exchanger will limit the cooling of the oil.

To repair the Thermo Valve: • Remove the End Cap from the assembly. As the Spring is compressed, caution must be taken when

removing the End Cap. • Replace the O Ring, Thermostat, Collar, and Spring. • Re-assemble.

The parts as indicated by the arrows (above – right) are included in the ‘DSC-111-1’ Thermo Valve Repair Kit.

End Cap

Spring

Minimum Pressure Valve Repair Kit. The Minimum Pressure Valve has two purposes when installed in the Rotary Screw Compressor Unit.

1. It allows the Unit to build up pressure (up to approx 65 psi) before allowing the compressed air to flow through the cooler and

2. it acts as a ‘one way’ or ‘check’ Valve, stopping air from flowing back from the Tank.

The Minimum Pressure Valve is defective and requires repair if the Unit is

• shut down and • air is bleeding from the Tank and • air is bleeding out of the Unloader – Solenoid

Set Screw

End Cap

To repair the Minimum Pressure Valve: • Remove the End Cap from the assembly. As the Spring is compressed, caution must be taken when

removing the End Cap. • Do not remove or turn the Set Screw in the End Cap, as it has been preset at the factory. • Replace the Plunger, Springs, and O Rings. • Apply lubricant to moving parts. • Re-assemble.

The parts as indicated by the arrows (above – right) are included in the ‘DSC-231’ Minimum Pressure Valve Repair Kit.

Page 20: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 20 -

‘CSC200’ Controller Description of Controller. The ‘CSC200’ Controller is the ‘brains’ of the ‘SC Series’ of Rotary Screw Compressor Units. It monitors, enables, and indicates the various functions of the Unit. The Controller is comprised of several levels of access, segregated into: - Main Level

- indicates the main operating parameters (eg, temperature, pressure, etc) of the Unit - User Level - allows access to change the Unit pressures, etc and indicates any Unit faults. - an Access Code is required. - Service Level - allows access to change some of the more restricted parameters. - an Access Code is required. - High Level - allows access to areas of the Controller that only factory personnel can access. - an Access Code is required. Controller Operator Interface.

Up. Scrolls forwards through the parameters, or increases the value of a parameter.

Stop. Causes the Unit to enter ‘Idle’ mode and then shut off.

Down. Scrolls backwards through the parameters, or decreases the value of a parameter. Reset.

Allows the Unit to be re-started after an error has occurred.

Escape. Allows you to move back one step.

Enter. Used to enter a new page, etc, or pressed to save changes to a parameter.

Start. Starts the Unit.

The Display above and at right indicates: • The system pressure is 7.0 Bar • The Unit is loading (compressing air) • The temperature of the compressed air

leaving the Air End is 85.0°C.

Page 21: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 21 -

‘CSC200’ Controller (cont’d) Unit Standard Operating Parameters. The chart below indicates the standard operating parameters programmed into the ‘CSC200’ Controller at the factory.

HP Load

Pressure (psi)

Unload Pressure

(psi)

High Pressure

Alarm (psi)

High Pressure

Shutdown (psi)

Idle Shutdown (minutes)

Max. Motor

Starts per Hour

Maint / Service Hours

30 10 5

40 16 3

50

100 120 125 130

16 3

4000

A description of the terminology used in the above chart is as follows: HP: Horsepower of the Unit.

Load Pressure: The pressure at which the Unit will begin to compress air.

Unload Pressure: The pressure at which the Unit will stop compressing air.

High Pressure Alarm: The pressure (above the Unload Pressure) at which an alarm will be noted.

High Pressure Shutdown: The pressure(above the Unload Pressure) at which an alarm will be noted and the Unit will shut off.

Idle Shutdown: The amount of time the Unit will idle (run but not compress air) after it has reached the Unload Pressure before shutting off.

Max Motor Starts Per Hour: The maximum number of times the Motor is allowed to start in one hour, this dictated by standard Engineering practices.

Maint / Service Hours: The maximum allowable time between maintenance/service of the Unit.

The above chart is supplied for information only. Serious consequences could result should any of the parameters be adjusted by someone who is not familiar with the correct and safe operation of the Unit. Any adjustments made to the above parameters by others (other than a qualified Technician) resulting in the incorrect operation of the Unit, damage to the Unit, or damage to property is not covered by the DV Systems Warranty. Please consult with your DV Systems Distributor or contact DV Systems directly should you have any questions or concerns about any of the information in the chart above, or in this manual.

Page 22: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 22 -

‘CSC200’ Controller (cont’d) Controller Structure. The chart below indicates the various fields of the ‘CSC200’ Controller, and which require an Access Code. As suggested on the previous page, only those qualified should be permitted to make any adjustments to the parameters. Main Level Available Without Acess Code User Level Requiring Acess Code: ‘0009’ Service Level Requiring Access Code: ‘0100’ High Level Requiring Access Code

Page ‘P00’ - User 01 Status / RTC 02 Information Screen 03 Delivery Temperature 04 Delivery Pressure 07 Run Hours 08 Loaded Hours 09 Service Hours 10 Motor Speed – rpm 11 Motor Speed - %

Page ‘P01’ – User Settings 01 Pu Unload Pressure 02 PL Load Pressure 05 Rt Standby Run-On Time 06 St Stop Run-On Time 07 Bt Blowdown Time 08 P> Pressure Units 09 T> Temperature Units 10 L> Language

Page ‘P02’ – Fault Log01 Logged Error #1 to 15 Logged Error #15

Page ‘P11’ – Pressure Schedule01 PS Press. Schedule Enable 02 Ct Real Time Clock 03 01 Schedule Setting #1 to 30 28 Schedule Setting #28

Page ‘P03’ – Shutdowns 01 TH Air Temp High Level 02 TL Air Temp Low Level 03 Pd Del. Press. High Level 04 Pl Del. Press Low Level

Page ‘P04’ – Alarms01 SD Service Due Timer 02 Td Del Temp High Level 03 Pd Del Press High Level

Page ‘P05’ – Inhibits 01 Td Del Air Temp Low

Level

Page ‘P06’ – Diagnostics Digital, Relay, and Analogue Inputs

Page ‘P07’ – Service Settings01 Star/Delta Time 02 Lt Load Delay Time 06 Ad Network Address 11 At Auto Restart Delay Time 13 Sh Starts per Hour

Page ‘P08’ – Speed Control

Page ‘P09’ – Calibration

Page ‘P10’ – System Settings Page ‘P80’ – Operational Page ‘P81’ – Configuration

Page ‘P82’ – Compressor Priority

Page 23: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 23 -

‘CSC200’ Controller (cont’d) Access Code Entry. To gain entry to areas of the Controller in which an Access Code is required:

Once you have entered the correct Access Code, you will have access to pages of the Controller reflecting that code.

Adjusting the parameters of the Controller could adversely affect the operation of the Unit. Only those individuals with knowledge of the Unit should be permitted to make any adjustments.

1. Press the ‘Up’ and ‘Down’ keys together. 2. The Screen shown below will appear.

3. Using the ‘Up’ and ‘Down’ keys, change the first digit of the Access Code to the appropriate number.

4. Press ‘Enter’ to move to the following digit. Using the ‘Up’, ‘Down’, and ‘Enter’ keys, input the Access Code.

Page 24: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 24 -

‘CSC200’ Controller (cont’d) Page Menus. Once the correct Access Code has been entered, access will be given to pages reflecting that Code. Refer to Page 22 for available pages. To select an appropriate page of the Controller, use the ‘Up’ or ‘Down’ arrows on the Controller. Once the appropriate page has been high-lighted, press ‘Enter’. The following will appear. Shown is Page 01. Pressing the ‘Enter’ key while over the ’01 Pu’ as noted above will make the following screen appear. To adjust a value, simply press the ‘Up’ or ‘Down’ key until the desired value is noted, then press ‘Enter’. Adjustment of Load and Unload Pressures. The Load and Unload Pressures may be altered from the factory settings. Simply input the appropriate Access Code (‘0009’) as indicated on Page 22 of this manual to gain access to ‘Page 01’ of the Controller. Adjust ’01 Pu’ Unload Pressure and ’02 PL’ Load Pressure as required, pressing ‘Enter’ after changing the values. Press ‘Escape to return to the Main Menu. Note: A) Do not adjust the pressures higher than the factory settings. B) Ensure that there is a minimum of 10 psi differential between the Unload and Load Pressures. C) Incorrectly adjusting the settings of the Controller could adversely affect the operation of the Unit.

UpDown

Enter

Display Code

Value and Units

Menu Page

Description of Display Code

Page 25: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 25 -

‘CSC200’ Controller (cont’d) Fault Log Menu. Any issues that the Unit may have are stored on a Fault Log. It places in its memory the last 15 faults in chronological order. If all 15 faults have been used, any new faults will become ‘01’, and all others will be moved back one step. This ensures that only the most recent faults appear. Shown below is a typical Fault Log Menu. The Fault Log is on ‘Page 02’ of the Controller and requires Access Code ‘0009’ to access it. Common Faults. Noted below are the most common Faults experienced. Alarms. There is an issue with the Unit, but it will still operate.

Code: Description: Most Common Items to Check:

A:2118 Delivery Pressure High Transducer dirty or faulty, pressure changed incorrectly, alternate external pressure source

A:2128 Delivery Temperature High Ambient temp high, Unit dirty, low oil level, no air flow through Unit, Temp Sensor defective

A:2816 Power Failure Occurred

A:4804 Service Hours Expired Service Unit and reset Service Timer (Page ‘P04’ on Controller)

Shutdown Errors. There is an issue with the Unit, and the Unit will not operate until the Fault has been addressed.

Code: Description: Most Common Items to Check:

E:0010 Emergency Stop Emergency Stop Button has been pressed, or is defective

E:0020 Anti Rotation Rotation of Motor wrong, Solenoid Valve not relieving pressure

E:0080 Motor Fault Motor drawing high amps, low voltage, Overload setting too low

E:0115 Delivery Pressure Sensor Fault Transducer not making good electrical contact, or defective

E:0119 Delivery Pressure High Transducer dirty or faulty, pressure changed incorrectly, alternate external pressure source

E:0121 Delivery Temperature Low Ambient temp too low

E:0125 Delivery Temp Sensor Fault Temperature Sensor not making good electrical contact, or defective

E:0129 Delivery Temperature High Ambient temp high, Unit dirty, low oil level, no air flow through Unit, Temp Sensor defective

Press ‘Enter’ to view details

of Fault

Page 26: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 26 -

‘CSC200’ Controller (cont’d) Service Due Timer (Fault ‘A:4804’). On Page 21 of this manual, values were given for various operating parameters for the Compressor Units ranging in size from 30 HP to 50 HP. One such parameter is the ‘Maintenance / Service Hours’, or simply put, the maximum allowable time (in hours) between service / maintenance of the Unit. For the 30 Hp to 50 HP Units, the Compressors must be serviced every 4000 hours. The Controller is programmed to count down from 4000 hours to 0 hours. Once it reaches 0 hours, an error code of ‘A:4804’ appears on the Controller screen, this indicating that service is due. If service is not carried out, the Timer will continue in negative values. Once the servicing of the Unit has been completed, the Timer must be reset to 4000 hours. To reset the ‘Service Due Timer’ parameter, the Service Level must first be accessed by means of an access code as follows. The appropriate Access Code is ‘0100’

Once you have entered the correct Access Code, you will have access to pages of the Service Level.

1. Use the ‘Down’ Key to high-light Page ‘P04’. 2. Press ‘Enter’. 3. At ’01 SD’ change the value from ‘0000’ to ‘4000’ using the ‘Up’ key. 4. Press ‘Enter’ to save the value. 5. Press ‘Escape’ twice to access the main operating page. 6. Press ‘Reset’ to clear the error message ‘A:4804’ Service Due Timer.

1. Press the ‘Up’ and ‘Down’ keys together. 2. The Screen shown below will appear.

3. Using the ‘Up’ and ‘Down’ keys, change the first digit of the Access Code to the appropriate number.

4. Press ‘Enter’ to move to the following digit. Using the ‘Up’, ‘Down’, and ‘Enter’ keys, input the Access Code.

Page 27: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 27 -

‘CSC200’ Controller (cont’d) Real Time Clock and Pressure Schedule. The ‘CSC200’ Controller is equipped with a ‘Real Time Clock’ which, when coupled with a Pressure Schedule, can modify the Unit’s pressures at specified times and on specific days of the week. To do this, the Real Time Clock must be programmed with the current local time. (This may have already been completed at the factory.) The Real Time Clock and Pressure Schedule are accessed on Page ‘P11’ of the Controller and by using the Access Code ‘0009’. Real Time Clock Programming On Page ‘P11’ of the Controller, item ’02 Ct’ indicates the current time as shown at right. This can be programmed as follows: 1. On ‘P11’, move down to item ’02 Ct’ and

press ‘Enter’. 2. When this screen first appears,

indicates the hour. Adjust using the ‘Up’ or ‘Down’ keys until the correct hour appears. (Please note the clock is set to in 24 hour mode.)

3. Press ‘Enter’ key, and the minutes ‚ become hi-lighted. 4. Adjust the minutes to the current time using the ‘Up’ or ‘Down’ keys, and press ‘Enter’ to move on to the day

of the month . Repeat this for the ‘day of the month’( ), ‘Month’ ( ), and ‘year’( ) items. 5. When the final item is set, the ‘day of the week’ ( ) will be automatically calculated and generated by the

Controller. The screen will then revert back to the main ‘P11’ screen. Pressure Schedule Basic Principles. As noted above, the ‘CSC200’ Controller is equipped with a manner to input a ‘Pressure Schedule’, thereby modifying the pressure generated by the Compressor Unit at specified times and days of the week. This enables the Unit to operate more efficiently while still meeting your air demands. This is done with in the following manner:

- Monday is considered to be ‘day of the week’ #1, with 00.00 hours being midnight. - Sunday is considered to be ‘day of the week’ #7 - the week operates from 00:00 hours on Monday to 23:59 on Sunday night. - ‘day of the week’ #8 is used to specify that the program is to be executed at the same time on each day of

the working week, Monday to Friday inclusive, and not on Saturday or Sunday. - ‘day of the week’ #9 is used to specify that the program is to be executed at the same time on each day of

the week, Monday to Sunday inclusive. - there are 28 settings available for use, some or all of which can be used. - the ‘day of the week’ and ‘time of day’ can be specified for each setting, as well as the ‘load’ and ‘unload’

pressure set points. - the Controller will use the current settings until the next chronological setting modifies the settings, the

pressure schedule is disabled, or a remote override is activated. - if a 0 psig Unload Pressure is specified, the Unit will unload, run-on, and move into a standby state.

Note: The pressure schedule will not start and stop the Compressor. The Compressor must be started before the Pressure Schedule will operate. When the pressure Schedule is activated, the symbol at right will appear on the Controller.

Page 28: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 28 -

‘CSC200’ Controller (cont’d) Pressure Schedule Settings. Before any adjustments can be made to the Pressure Schedule, the ‘Pressure Schedule’ function must be deactivated (Item ’01 PS’ on ‘P11’, ‘PS=0’) or the Unit must be stopped. Shown to the right is a typical Pressure Schedule, this visible on ‘P11’. Shown is the ‘pressure schedule’ (’01’), the ‘day of the week’ (’1’ = Monday), and the time (‘6:30’ am) To enter a new Pressure Schedule:

1. Navigate to an empty pressure schedule item,

one that shows ‘0.00.00’. 2. Press ‘Enter’ to access the pressure schedule to

be used. 3. The pressure schedule item screen will appear,

and the ‘day of the week’ sub item will be hi-lighted, as shown at right.

4. Adjust the value for the ‘day of the week’ ( ) using the ‘Up’ or ‘Down’ key. Once the appropriate value has been input, press ‘Enter’.

5. Input the time ( and ), unload pressure ( ), and load pressure ( ).

To Adjust an Existing Pressure Schedule:

1. Navigate to the appropriate pressure schedule item and press ‘Enter. 2. Follow the same procedure as entering a new Pressure Schedule (above) but press ‘Enter through the

items not needing changes. To Delete an Existing Pressure Schedule:

1. Navigate to the appropriate pressure schedule item and press ‘Enter’. 2. At ‘day of the week’ ( ), use the ‘Down’ key until ‘0’ is shown. Press ‘Enter’.

All remaining sub-items will be reset to zero, and the item will be deleted from the pressure schedule list. To operate the Unit using the ‘pressure schedule’, the ‘Pressure Schedule’ function must be reactivated (Item ‘01’ on ‘P11’, ‘PS=1’). To Deactivate an Existing Pressure Schedule for Unscheduled Use: If the Compressor is to be used outside of the hours as programmed into the Pressure Schedule, the Pressure Schedule function must be turned off. To operate the Unit outside of the ‘pressure schedule’, the ‘Pressure Schedule’ function must be deactivated (Item ‘01’ on ‘P11’, ‘PS=0’). Note: Once finished using the Unit outside of the ‘pressure schedule hours’, the Pressure Schedule must be

reactivated (Item ‘01’ on ‘P11’, ‘PS=1’)

Page 29: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 29 -

Sequencing with ‘CSC200’ Controller If you have purchased (2) or more Rotary Screw Units each having the ‘CSC200’ Controller, it is possible to sequence the Units in order that they turn on and off at various intervals. This feature becomes important if you wish to ensure that the Units have roughly the same amount of operating hours over a period of time. Sequencing the Units involves two steps, namely a) changes to the physical wiring of the Controllers and b) changes made to the actual operating parameters of the Controllers. Wiring of the Units is as follows: Controllers are to be connected as illustrated in the figure at right.

1. Connect one end of an earth screened, twisted pair cable to port ‘X07’ of one controller.

2. Connect the other end of the cable to port ‘X07’ of the second controller.

3. Connect grounding wire to a controller housing.

Controller Programming is as follows: One compressor will be the ‘Master’ and the remaining Unit(s) will be the ‘Slave(s)’. When built, the Units have already been designated as ‘Master’ and ‘Slave, and the Controllers have been programmed accordingly.

Note: Compressors should be powered but not running during set up. Operation and Status: Each unit in the system must be started by means of its own ‘Start/Stop’ Switch. The Master Unit cannot start a Unit that has been switched to ‘Stop’. The Compressor Units are given the following designations which is shown on the Controller screens. ‘A’ The active Compressor Unit ‘B’ The back-up to the ‘A’ active Unit. ‘C’ The back-up to the ‘B’ back-up Unit Etc. The operating ‘status’ of each Unit is as indicated: ‘A’ If the Unit letter is on continuously, the compressor is loading. ‘B’ If the Unit letter is slow flashing, the compressor is unloaded. ‘B’ If the Unit letter is fast flashing, loading of the compressor is requested. ‘C’ If the Unit letter is replaced by a dash, the compressor is unavailable The system pressure is detected and regulated by the controller on the Master Unit. The controllers on the Slave Units(s) will ignore its own pressure set points when operating with the Master Unit. If the Master Unit is unavailable or communication with the Master Unit is disrupted, the Slave Units will operate on their own pressure set points. Once the Master is again available, pressure detection and regulation will revert back to the Master. To Start the Sequencing Feature:

1. Press ‘Start’ button on the connected controllers. 2. On the main menu screen, use the ‘Up’ arrow until ‘ISC SEQUENCE’ screen is displayed on the screen of

the Master controller. Press the ‘Start’ button to start sequencing.

RS485

L1L2 L1L2 L1L2X07 X07 X07

1 2 3

Page 30: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 30 -

Separator Filter and Refrigerated Air Dryer Your Unit may have been shipped with a Separator Filter and Refrigerated Air Dryer, these to assist in providing good quality air to your point of use. Shown below is a typical installation showing the Compressor, Air Receiver, Refrigerated Air Dryer, and Filters. More detailed information concerning the Dryer Unit is included in the Dryer manual. The information contained in this manual is a ‘quick reference’ only.

Air Receiver

Dryer Controls.

On/Off Button

LED’s for Compressor, Drain, and Fan

Test/Programming Buttons

Compressor Unit Refrigerated Air Dryer

Readout

10 Micron Separator

Filter

Coalescing Filter

Page 31: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 31 -

Separator Filter and Refrigerated Air Dryer (cont’d) The Dryer will operate as follows:

• Pressing the ‘On/Off’ Button for 3 seconds will start the Unit • There is a time delay of up to 2 minutes before the Refrigerant Compressor starts. • The Condenser Fan will start approx. 30 seconds there-after. • The Fan will not normally run at full speed, this indicated by a flashing LED • The readout will initially show ambient temperature indicated by 3 horizontal bars on the readout • Once the Fan and Compressor start, the dew point of the Unit will decrease to approx. 1°C, this indicated

by 1 or no horizontal bars. • Once at approx. 1°C, the Fan will stop, only to be called to run again once the temperature increases to

approx. 5°C • Pressing the ‘On/Off’ Button (when the Unit is operating) will run the Fan at full speed for several

seconds, after which the Unit will stop. (The LED will be on continually while the Fan runs at full speed.)

• As well as showing the dew point, the readout may indicate several fault codes as suggested below. The readout will indicate a variety of ‘fault codes’, the most common being as follows:

Motors. Typical Dryer Operation.

Typical Fault Codes.

Energy Saving Mode. • The Dew Point has been running at below -1°C for over 6

minutes. • The Unit will automatically restart operation at 6°C.

Temperature Probe Alarm. • The Temperature Probe is not working properly. It may

not be connected to the Board, or the Probe may be defective.

• Replace the Probe if necessary.

High Temperature Alarm. • The Dew Point has been running at above 12.5°C for

over 6 minutes. The Unit must be manually turned off and on.

• The fault could be caused by a dirty radiator, high ambient temperature, a faulty Fan, or a faulty refrigerant Compressor, to name only a few.

Page 32: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 32 -

Separator Filter and Refrigerated Air Dryer (cont’d) As previously noted, the Separator Filter should be located between the Compressor and the Refrigerated Dryer. It contains a 10 micron Separator Element which protects the Dryer Unit by removing liquids and solid particles 10 microns and larger. To replace a dirty Filter Element:

• Shut the Compressor Unit off. • Bleed any compressed air from the system to ensure there is no pressure at the Filter. • Unscrew the Bowl from the assembly, exposing the dirty Filter Element. • Twist the Filter Element until it comes loose. • Replace with a new 10 micron Separator Filter Element • Clean any debris from the inside of the Bowl, and re-install. • Cat-eye Gauge will return to green when Filter is once again under pressure.

Typical Separator Filter.

Arrow Indicates Direction of Air Flow Cat-eye Gauge (120 CFM Filters)

Green = Filter Element is Clean Red = Filter Element is Dirty

AutoDrain Bowl which Contains Filter Element and AutoDrain

The label shown above is included with a replacement Filter Element, and should be affixed to the outside of the Bowl for future reference.

Filter Element Replacement.

Needle Type Gauge (177+ CFM Filters) Blue = Filter Element is Clean Red = Filter Element is Dirty

Page 33: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 33 -

Trouble Shooting Guide The ‘Conditions’, ‘Causes’, and ‘Suggested Corrections’ as indicated below and on the following page(s) are only a guideline for failures that we have found to be most common. Though this information is provided in this booklet, it is assumed and expected that any personnel involved in the servicing of an Air Compressor Unit is knowledgeable with this type of equipment. Do not attempt to service a Compressor Unit unless you are familiar with it, as there are many issues that may come into play, the most important being personal safety and the welfare of the Unit. Should you have any questions, or require servicing to your Unit, please contact your local DV Systems Distributor/Service Center. Condition: Cause: Suggested Correction: A. Unit won’t start.

No power to the Unit. Loose and/or missing wires in the electrical circuit. Emergency Stop Button pressed in. Motor Overload is tripped. Compressor over-heated and stopped. Compressor stopped by over-pressure. Unit has ‘timed out’ / shut off because pressure has not gone below cut-in pressure of 100 psi. Power interruption.

Check that power at the disconnect or breaker is on. Also, check any primary and secondary fuses. Check that all wiring connections are tight. With a wiring schematic, check that all wiring is present and correct. Release by twisting and pulling out. Reset the overload. Insufficient air flow to cool Unit. Ambient temperature too high. Heat Exchanger is dirty. Faulty Temperature Switch. Oil level is low. Solenoid Valve faulty. Seals on Intake Valve leaking. Intake Valve Spring broken. Pressure Transducer stopped Unit. Lower

maximum pressure setting. Drop pressure below 100 psi. Reset the Unit.

When servicing the Air Compressor, shut off all power to the Unit, and drain it of air pressure.

Page 34: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 34 -

Trouble Shooting Guide (cont’d) Condition: Cause: Suggested Correction: B. No or Insufficient Air Flow.

Air Filter is dirty. Oil Separator is blocked. Intake Valve is faulty. Air leaks in the system. Pressure limits are incorrectly set. 2 Way Solenoid Valve is open. Belt are broken or slipping

Replace the Air Filter. Replace the Oil Separator. Repair or replace the Intake Valve. Check the Unit and system for air leaks. Adjust the pressure settings. Check the wiring to the Solenoid and replace as necessary. Check Belt tension and that Belts are in good condition.

C. Unit is overheating.

Ambient temperature is too high. Blocked air circulation at the Unit. Heat Exchanger is dirty. Oil level is too low. Using wrong type of compressor oil. Thermo Valve is faulty. Oil Filter is blocked. Temperature Sensor is faulty. Thermostat is faulty. Pressure is too high. Cabinet door/panel is open/off.

Check cooling air circulation. Check the air circulation in and around the Unit. Clean the Heat Exchanger Add oil as required. Change to the factory recommended oil. Check and repair as necessary. Replace the Oil Filter. Check the wiring to the Temperature sensor. Replace the Sensor if necessary. Replace the Thermostat. Lower the pressure setting. Secure the door/panel to the Unit.

D. Compressor Starts Slowly.

Intake Valve not functioning properly. Ambient temperature is too low. Minimum Pressure Valve leaking back to Air End. Minimum Pressure Valve setting is too high. Using wrong type of oil.

Check Intake Valve operation. Repair or replace as required. Stop and restart once ambient increases. Repair or replace the Minimum Pressure Valve. Adjust Minimum Pressure Valve setting to 65 psi. Change to factory recommended oil.

Page 35: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 35 -

Trouble Shooting Guide (cont’d) Condition: Cause: Suggested Correction: E. Intake Valve Leaks Oil

When Unit Stops.

Intake Valve Seal leaks. Intake Valve stuck in open position or 3 Way Solenoid not working properly. 2 Way Solenoid not functioning.

Repair using an Intake Valve Repair Kit. Repair or replace the Intake Valve or 3 Way Solenoid. Replace the 2 Way Solenoid.

F. Oil Consumption is Too

High.

Oil level is too high. Oil Return Line (Scavenge Line) is blocked. Oil Separator is saturated with oil. Wrong type of oil used. Unit is operating at too high a temperature. Oil leak. Unit load is light or excessive load/idle cycles.

Reduce the oil level to the proper level. Clean and/or replace the Scavenge In-Line Filter. Replace the Oil Separator. Change to factory recommended oil. See ‘Section C’. Repair oil leak. Ensure Unit is set to operate at correct pressures, and there is a minimum of 10 psi differential. Also the Unit could be oversized for the tank capacity.

G. Compressor Surges.

Restriction in Heat Exchanger or Hoses. Pressure Transducer setting is incorrect or malfunctioning. Blockage at Unit outlet. Dryer is freezing up, not allowing air to pass through. Air Receiver is too small.

Flush out or replace. Set pressure as per instructions or replace. Check for obstructions in outlet piping. Check that the Dryer parameters are correct. Increase dew point to 2.0 if required. Use a minimum 120 Gallon Tank.

H. High Power Consumption.

Improper air pressure settings. 2 Way Solenoid is not functioning. The voltage in the building is too low or there is a phase imbalance. The Motor is failing.

Reset the pressure as per factory defaults. Inspect or replace as necessary. Contact an Electrician to verify. Have Motor inspected.

I Fault Alarms.

Emergency Stop. High Temperature. Low Temperature. High pressure.

Ensure Emergency Stop Button is not pressed in. See ‘Section C’. Ambient temperature is too low. Increase to 10°C. Check the pressure settings, the Pressure Transducer and the wiring to the Transducer.

Page 36: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

SC3050 Nov ‘12

- 36 -

Limited Warranty : SC Series Screw Compressors

The manufacturer warrants the product manufactured by it and sold to the original purchaser, when properly installed, operated, applied, and maintained in accordance with procedures and recommendations outlined in the manufacturer’s instruction manuals, to be free of defects in material and workmanship for a period of one (1) year from the date of installation, not to exceed eighteen (18) months from the date of manufacture, provided such defect is discovered and brought to the manufacturers attention within the aforesaid warranty period, conditional upon the following:

1) Genuine ‘DEV-3000’ Lubricant and Parts are used for the full warranty period. 2) The Unit is maintained in accordance with the manufacturer’s instruction manual for the Unit, with the following minimum maintenance

requirements: A) Complete Oil change every 8000 hours (not to exceed 12 months) from the date of initial start-up using ‘DEV-3000’ Lubricant. When

operating in adverse conditions, Oil changes must be done more frequently. B) Oil Filter must be changed every 4000 hours (not to exceed 6 months) from the date of initial start-up using the appropriate DV Systems part.

When operating in adverse conditions, Oil Filter changes must be done more frequently. C) Air Intake Filter must be changed every 2000 hours (not to exceed 6 months) from the initial date of start-up using the appropriate DV

Systems part. When operating in adverse conditions, Air Intake Filter changes must be done more frequently. D) Air/Oil Separator Filter must be changed every 8000 hours (not to exceed 12 months) from the date of initial start-up using the appropriate

DV Systems part. When operating in adverse conditions, Air/Oil Separator changes must be done more frequently. E) Appropriate and complete maintenance records must be kept by the End User. As well, the End User must retain copies of invoices

indicating the timely purchase of the DV Systems Compressor Oil and maintenance/service parts. All records and invoices must be kept for the duration of the manufacturer’s warranty period.

3) Disclaimer: A) The following items are considered normal wear items, and are warranted for a period of one (1) year from the date of installation, not to

exceed eighteen (18) months from the date of manufacture; the Shaft Seal on the Air End Drive Shaft, the Intake Valve Assembly (and its components), and the Minimum Pressure Valve.

B) All electrical components are warranted for a period of one (1) year from the date of installation, not to exceed eighteen (18) months from the date of manufacture.

An additional four (4) year extended Air End Warranty and a four (4) year extended Three Phase Baldor Motor Warranty are available on those

Units that: A) have been registered with the manufacturer within thirty (30) days from the date of purchase, this done by returning the ‘DV Systems Rotary

Screw Compressor Start-Up Sheet’ and B) have been maintained in accordance with the manufacturer’s instruction manual as noted in ‘2’ above.

The manufacturer will repair or replace any product or part determined to be defective by the manufacturer within the warranty period, provided such defect occurred in normal service and is not the result of misapplication, misuse, abuse, neglect, incorrect maintenance, accident, or normal wear. Normal maintenance items requiring routine replacement are not warranted. Please refer to the appropriate service bulletin to determine normal maintenance requirements. The warranty covers parts and labour for the warranty period (excluding the Three Phase Baldor Motors. Labour is not covered in the (4) year extended Baldor Motor Warranty.) Either repair or replacement shall be at the sole option of the manufacturer. Any service performed on the product by anyone other than the manufacturer must first be authorized by the manufacturer. Unauthorized service voids the warranty and any resulting charge or subsequent claim will not be paid. Products repaired or replaced under warranty shall be warranted for the unexpired portion of the warranty applying to the original product, based on the original date of invoice as outlined above. There is no other expressed warranty. Implied warranties including those of merchantability and fitness for a particular purpose are limited to one (1) year from the date of invoice to the extent permitted by law and any and all implied warranties are excluded. This is the exclusive remedy. Liability for consequential damages under any and all warranties are excluded to the extent exclusion is permitted by law. This warranty gives you specific rights, and you may also have other rights within your jurisdiction. This warranty does not cover:

1) Merchandise that has become inoperative because of ordinary wear, misuse, neglect, accident, or improper and unauthorized repair or alteration. 2) Electric Motors manufactured and identified as the product of another company. 3) Compressor Units that have not been properly maintained in accordance with the recommended maintenance and lubrication change procedures

and/or that have been subject to inordinate use through being inadequately sized or poorly installed. 4) Compressor Units using other than the recommended lubricant. 5) Costs occasioned by the removal, replacement, or repair of merchandise (other than by DV Systems) without previous authorization from DV

Systems. 6) Expenses incurred in travel or lodging beyond a 100 kilometre (60 mile) distance from the nearest DV Systems Authorized Service Centre. 7) Expenses incurred in the return of equipment for inspection purposes to the manufacturers facility. All returns must be pre-authorized, returned

‘Freight Prepaid’, and accompanied by a ‘Return Material Authorization (RMA) Number’ (obtainable through DV Systems). 8) Products, parts, materials, components, or accessories manufactured by others or supplied in connection with the sale of the manufacturers

products. 9) Repair and transportation costs of merchandise determined not to be defective under the terms and conditions of this warranty. 10) The cost of rental or loaner equipment while the customer’s original equipment is being assessed, repaired, or replaced. 11) Consequential damages in the event of product failure.

All decisions by DV Systems Inc. with regard to this policy shall be final. DV Systems will not be responsible for any claimed defective materials returned other than in accordance with this statement of policy or without our prior authorization. DV Systems 490 Welham Road Tele: (705) 728-5657 Barrie, Ontario, Canada Fax: (705) 728-4974 L4N 8Z4

Page 37: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

72 5

/8"

4"

28 1/4"

19 15/16"

1/2" HOLES

HINGED FRONT DOORS

CSC200MICROPROCESSOR

CONTROLS

EMERGENCY STOP

47 3/8"35 3/8"

27"

9 5/16"

17 5

/8"

1 3/

8"

REMOVABLESIDE PANELS

SOUNDBAFFLE

AIR OUTLET1-1/4" NPT

DUCTIBLECOOLING AIR

INLET

24 1

/8"

20 7/16"

5 1/

2"5"

2 13/16"

POWER IN1" CONDUIT

OPENING

DUCTABLEEXHAUST AIR

OUTLETINSTALLATION REQUIREMENTS:

1. MAINTAIN 3 FEET DISTANCE FROM WALLS AND OTHER OBJECTS FOR PURPOSE OF COOLING AND SERVICING.

2. COMPRESSOR MUST BE LEVEL AND ANCHORED DOWN TO SOLID, LEVEL FLOOR USING ISOLATOR PADS.

3. AMBIENT CONDITIONS: 10ºC (50ºF) MIN. 40ºC (104ºF) MAX.

*FACTORY SET AT 120PSI, 145PSI AVAILABLE AS OPTION

MODEL NO. HP PRESSURE PSI*

SCFMMOTOR

NOMINAL SOUND @ 1 METRE

MOTOR VOLTAGEWEIGHT

LBS120 PSI 145 PSI MOTOR AMP

SC40-04 40 105-120 165 153 3450 RPMOPEN 73 dBA 208 V

106 A230 V98 A

460 V49 A

575 V37.6 A 1265

SC50-04 50 105-120 212 197 3450 RPM OPEN 76 dBA 200 V

133 A230 V116 A

460 V58 A

575 V47 A 1265

REV. DATE REVISION DESCRIPTION PCN NO.

IMPORTANT NOTE: This print is the confidential property of DV SYSTEMS, INC. It is not to be used or reproduced in any manner, nor submitted to other parties for examination without the prior approval of DV SYSTEMS, INC. DV SYSTEMS, INC. is continuously trying to improve its products, specifications subject to change without notice.

DESCRIPTION OF DRAWING

DRAWING NO. SHT NO REV.

NAME OF PROJECT

DRAWN BY CHECKED BY DATE SCALE

SC40-50 SCREW COMPRESSOR

LT 12/30/10 N.T.S

SALES-ENGINEERING DRAWING

SC-40-04 SC-50-04

Page 38: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

72 5

/8"

4"

28 1/4"

19 15/16"

EMERGENCY STOP

CSC200MICROPROCESSOR

HINGED FRONT DOORS

1/2" MOUNTING HOLES

24 1

/8"

20 7/16"

VARIABLE SPEED DRIVEMAINTAIN 2FT MIN. FROMWALL FOR VENTILATION

POWER IN3/4" CONDUITOPENING

HINGED ACCESSDOOR

34 5/8"

27"

1 3/8"

48 1/4"

*FACTORY SET AT 120PSI, 145PSI AVAILABLE AS OPTION**MOTOR AMP IS 100% OF FULL LOAD, @70% & 40% THE AMP WILL DECREASE PROPORTIONATELY

INSTALLATION REQUIREMENTS

1. MAINTAIN 3 FEET DISTANCE FROM WALLS AND OTHER OBJECTS FOR PURPOSE OF COOLING AND SERVICING 2. COMPRESSOR MUST BE LEVEL AND ANCHORED DOWN TO SOLID FLOOR

3. AMBIENT CONDITIONS: 10ºC (50ºF) MIN. 40ºC (104ºC) MAX.

MODEL NO. HP PRESSURE PSI*

SCFM @ 120 PSIMOTOR

NOMINAL SOUND @ 1 METRE

MOTOR VOLTAGEWEIGHT

LBS100%CAP.

70%CAP.

40%CAP. MOTOR AMP

SC50VSD 50 105-120 212 148 84 3450 RPM OPEN 76 dBA 200 V

133 A230 V116 A

460 V58 A

575 V47 A 1265

REV. DATE REVISION DESCRIPTION PCN NO.

IMPORTANT NOTE: This print is the confidential property of DV SYSTEMS, INC.It is not to be used or reproduced in any manner, nor submitted to other parties for examination without the prior approval of DV SYSTEMS, INC.DV SYSTEMS, INC. is continually trying to improve its products, specificationssubject to change without notice

ALL DIMENSIONS ARE IN INCHES

FRACTIONAL DIMENSIONS:DECIMAL DIMENSION:ANGLES:*UNLESS OTHERWISE SPECIFIED

1/32.0051

DESCRIPTION OF DRAWING

DRAWING NO. SHT NO REV.

NAME OF PROJECT

DRAWN BY CHECKED BY DATE SCALE

SC40-50VSD SCREW COMPRESSOR

LT 4/15/10 N.T.S

SALES-ENGINEERING DRAWING

SC40-04VSDSC50-04VSD

Page 39: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

12

34

5

6

7

8

99

10

1115

16

17

12

13

14

4

3

24

1625

29

30

65

13

2627

28

18

1919 2020

21

23

22PAGE 1 OF 3

NO. PART NO. DESCRIPTION QTY.1 DSC-559 FAN SHROUD SEAL 1

2 DSC-160 FAN SHROUD 1

3 SS-657 3/8 HEX NUT 84 SS-1510 3/8 LOCKWASHER 85 DSC-597 1/4 X 3/4" BOLT 86 SS-1505 1/4 LOCKWASHER 87 SS-655 1/4 HEX NUT 48 DSC-227 FAN SHROUD BRACKET 49 DSC-264 FAN & TAPER LOCK BUSHING ASSEMBLY 110 DSC-602 AIR END 111 MO-9261 MOTOR 25 & 30HP, 200 VOLT 111 MO-9262 MOTOR 25 & 30HP, 230/460 VOLT 111 MO-9263 MOTOR 25 & 30HP, 575 VOLT 111 MO-9303 MOTOR 40HP, 200 VOLT 111 MO-9304 MOTOR 40HP, 230/460 VOLT 111 MO-9305 MOTOR 40HP, 575 VOLT 111 MO-9264 MOTOR 50HP, 200 VOLT 111 MO-9265 MOTOR 50HP, 230/460 VOLT 111 MO-9266 MOTOR 50HP, 575 VOLT 112 SS-29 3/8 X 2" BOLT 413 SS-1525 3/8 FLAT WASHER 814 DSC-552 ISOLATOR 415 SS-661 5/8 HEX NUT 416 SS-1508 5/8 LOCKWASHER 817 SS-81 5/8 X 1-3/4" BOLT 4

NO. PART NO. DESCRIPTION QTY.24 DSC-209 MOTOR / AIREND FRAME ASSEMBLY 125 DSC-241 M16 X 35MM AIREND BOLT 426 DSC-614 SHAFT KEY 127 PU-9241 25, 30HP AIREND PULLEY (5V4.9 3-GROOVE & BUSHING SD35) 127 PU-9242 40, 50HP AIREND PULLEY (5V4.9 4-GROOVE & BUSHING SD35) 128 PU-9245 25HP MOTOR PULLEY (5V7.5 3-GROOVE & BUSHING SF 1-7/8) 128 PU-9239 30HP MOTOR PULLEY (5V8.5 3-GROOVE & BUSHING SF1-7/8) 128 PU-9258 40HP MOTOR PULLEY (5V5.9 4-GROOVE & BUSHING SD 1-7/8) 128 PU-9240 50HP MOTOR PULLEY (5V7.1 4-GROOVE & BUSHING SF1-7/8) 129 DSC-258 BELTS 25, 30HP 5VX600 329 DSC-447 BELTS 40HP 5VX560 429 DSC-257 BELTS 50HP 5VX580 430 DSC-221 BELTGUARD 1

NO. PART NO. DESCRIPTION QTY.18 DSC-203 MOTOR BASE TENSION ROD 119 DSC-550 3/4 NYLOCK NUT 220 DSC-555 3/4 WASHER 221 DSC-242 3/4 HEX NUT 122 DSC-549 3/4 X 3-1/2" BOLT 123 DSC-222 CYLINDER FOR MOTOR BASE TENSION ROD 1

REV. DATE DESCRIPTION PCN NO.

C 7/13/09 DSC-257 50HP BELT ADDED ---

D 2/07/11 MOTOR SPECS UPDATED ---

E 3/21/12 40HP MOTOR P/NS ---

IMPORTANT NOTE: This print is the confidential property of DV SYSTEMS, INC. It is not to be used or reproduced in any manner, nor submitted to other parties for examination without the prior approval of DV SYSTEMS, INC. DV SYSTEMS, INC. is continually trying to improve its products, specifications subject to change without notice.

DESCRIPTION OF DRAWING

DRAWING NO. SHT NO REV.

NAME OF PROJECT

DRAWN BY CHECKED BY DATE SCALE

SCREW COMPRESSOR 25-50HP PARTS LISTING

J.CHO 04/04/07 N.T.S

MECHANICAL DRIVE

SC-25 SC-40SC-30 SC-50 E

Page 40: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

1

2

3

6

4

5

7

4

5

8

9

12

10

13

11

14

15

16

4

23

19

22

21

2024

25

5

4

26

27

29

30

31 32

17

15

28

18

33

34

3536

37 38

35

35

39

40

4142

PAGE 2 OF 3

NO. PART NO. DESCRIPTION QTY.

1 DSC-155 HEAT EXCHANGER 1

2 DSC-122 BONDED WASHER 1-1/4" 1

3 DSC-123 HOSE ADAPTER R1-1/4" - JIC 16 1

4 DSC-120 BONDED WASHER 3/4" 4

5 DSC-121 HOSE ADAPTER R3/4" - JIC 12 3

6 DSC-146 AIR HOSE 1

7 DSC-455 OIL OUTLET HOSE TO HEAT EXCHANGER 1

8 DSC-456 OIL RETURN HOSE FROM HEAT EXCHANGER 1

9 DSC-151 AIR/OIL SEPARATOR FILTER 1

10 DSC-624 OIL FILTER 1

11 DSC-288 MANIFOLD ASSEMBLY O-RING 2

12 DSC-628 MANIFOLD-SCAVENGE LINE O-RING 1

13 DSC-289 MANIFOLD ASSEMBLY 1

14 DSC-287 AIR/OIL RECEIVER 1

15 DSC-625 AIR END DISCHARGE HOSE 1

16 DSC-618 OIL FILL PLUG (HEX HEAD) 3/4" BSPP 1

17 DSC-635 OIL OUTLET HOSE FROM TANK 1

18 DSC-636 OIL RETURN HOSE TO AIR END 1

19 DSC-433 ELBOW 3/4" NPTM X JIC 12 1

20 DSC-163 ELBOW 3/8" NPT 1

21 SS-2108 3/8 X 2" NIPPLE 1

22 DSC-137 BALL VALVE 3/8" NPTM X 3/8" NPTF 1

23 SS-9924 PIPE CAP 3/8" NPT 1

24 DSC-142 INTAKE VALVE 1

25 DSC-138 INTAKE VALVE O-RING 1

26 DSC-602 AIR END 1

27 DSC-271 AIR END TO ELBOW GASKET 1

28 DSC-620 THERMAL PROBE PLATE O-RING 1

29 DSC-001394 THERMAL PROBE MOUNTING PLATE 1

30 DSC-001238 CSC200 TEMPERATURE PROBE SENSOR 1

31 DSC-607 INTAKE FILTER ASSEMBLY 1

32 DSC-606 AIR FILTER ELEMENT 1

33 DSC-294 M12-1.75 X 30 HSCS 2

34 DSC-243 M12-1.75 X 80 HSCS 2

35 DSC-244 M12 LOCKWASHER 8

36 DSC-245 M12-1.75 X 35 HSCS 4

37 DSC-001217 1/4" BONDED WASHER 1

38 DSC-001360 CSC200 TEMPERATURE SENSOR CABLE 1

39 DSC-001235 SEPARATOR SPOUT 1

40 DSC-298 5/16-18 X 2" SHCS 4

41 DSC-001907 OIL SIGHT GLASS 1

42 DSC-002259 COPPER WASHER 3/4"BSPP WD 1

REV. DATE REVISION DESCRIPTION PCN NO.

IMPORTANT NOTE: This print is the confidential property of DV SYSTEMS, INC. It is not to be used or reproduced in any manner, nor submitted to other parties for examination without the prior approval of DV SYSTEMS, INC. DV SYSTEMS, INC. is continually trying to improve its products, specifications subject to change without notice.

DESCRIPTION OF DRAWING

DRAWING NO. SHT NO REV.

NAME OF PROJECT

DRAWN BY CHECKED BY DATE SCALE

SCREW COMPRESSOR 30-50HP PARTS LISTING

J.CHO 4/30/07 N.T.S

SYSTEM COMPONENTS

SC40-04 SC50-04 HDSC-298,001235 ADDED 11-26F 1/06/12

G 5/31/12 DSC-001907 ADDED, DSC-312,444 RMVD 12-01H 9/20/12 DSC-002259 ADDED, DSC-102 RMVD 12-23

Page 41: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting

33

44

5

39

7

61

2

44

888

1212

9 10 1133

17

18

19

13

20

22

2324 25

26

13

28

20

17

21

27

14

13

13

28

13

14

30

29

31

M.P.V. VALVE REPAIR KIT DSC-231

INTAKE VALVEREPAIR KITDSC-176

THERMO. VALVEREPAIR KITDSC-111-1

ATTACHED TO TOP OF TANK

DSC-287

2 1

32

IN

16

37

34

33

35

36

36

36

3636

36

2 1

38

PAGE 3 OF 3

NO. PART NO. DESCRIPTION QTY.1 DSC-123 HOSE ADAPTER R1-1/4" - JIC 16 12 DSC-122 BONDED WASHER 1-1/4" 13 DSC-121 HOSE ADAPTER R3/4" - JIC 12 44 DSC-120 BONDED WASHER 3/4" 45 DSC-712 THERMO VALVE CAP 16 DSC-289 MANIFOLD ASSEMBLY 17 DSC-288 MANIFOLD ASSEMBLY O-RING 18 DSC-427 BONDED WASHER 3/8" 39 DSC-279 ADAPTER 3/8" BSPP(M) - 3/8" NPT(F) 110 DSC-436 ADAPTER 3/8" NPT(M) - 1/2" NPT(F) 111 TIA-6165 165 PSI SAFETY VALVE 1/2" NPT 112 DSC-278 ADAPTER 3/8" BSPP(M) - 1/4" BSPP(F) 213 DSC-158 1/4" ELBOW X 6MM TUBE FITTING 514 DSC-157 1/4" TEE X 6MM TUBE FITTING 216 DSC-001237 CSC200 PRESSURE TRANSDUCER 117 DSC-186 1/8" TEE X 6MM TUBE FITTING 218 DSC-380 1/4" STRAIGHT X 6MM FITTING 119 DSC-375 CHECK VALVE 1/4" FEMALE 120 DSC-175 1/8" STRAIGHT X 6MM TUBE FITTING 221 DSC-001497 1/8" BREATHER VENT 122 DSC-102 ANTI-REVERSE SWITCH 123 DSC-001359 ELBOW 1/8" NPT(M) - 1/8" NPT(M) 124 DSC-677 SCAVENGE LINE ORIFICE FITTING 125 DSC-263 BONDED WASHER 1/8" BSPP 126 DSC-268 COUPLING 1/4"NPT FEMALE 127 DSC-432 SOLENOID DIN CONNECTOR 128 DSC-185 1/8" ELBOW X 6MM TUBE FITTING 229 DSC-602 AIR END 130 DSC-142 INTAKE VALVE 131 DSC-382 PNEUMATIC TUBE 6MM OD CLEAR ---32 DSC-612 INLINE FILTER 133 DSC-140 3-WAY SOLENOID NC 134 DSC-162 2-WAY SOLENOID NO 135 DSC-001366 CSC200 PRESSURE TRANSDUCER CABLE 136 DSC-482 PNEUMATIC TUBE 6MM OD BLACK ---37 DSC-001358 CHECK VALVE 1/8" FEMALE 138 SS-1527 1/2" FLAT WASHER 239 DSC-711 THERMO VALVE O-RING 1

REV. DATE REVISION DESCRIPTION PCN NO.

IMPORTANT NOTE: This print is the confidential property of DV SYSTEMS, INC. It is not to be used or reproduced in any manner, nor submitted to other parties for examination without the prior approval of DV SYSTEMS, INC. DV SYSTEMS, INC. is continually trying to improve its products, specifications subject to change without notice.

DESCRIPTION OF DRAWING

DRAWING NO. SHT NO REV.

NAME OF PROJECT

DRAWN BY CHECKED BY DATE SCALE

SC40-50 SCREW COMPRESSOR

LT 6/27/08 N.T.S

PNEUMATIC DIAGRAM

SC40-04 SC50-04 H

NEW 2-WAY SOLENOID,ANIT-ROT'N SWITCH 11-01F 1/05/11G 1/06/12 ---DSC-711,712 ADDEDH DSC-312,444 REMOVED5/31/12 11-01

Page 42: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting
Page 43: SC30-50-04 Manual Nov12 - DV Systems - Industrial Air ...dvcompressors.com/.../2013/04/SC30-50-04-Manual-Nov12.pdfSeparator Filter & Refrigerated Air Dryer …………. 30 Trouble-Shooting