SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS IN SARAWAK 2020 Notes to tenderers: 1. This is only a cover page for this document. Please obtain the full set from the JKR Sarawak webpage. 2. The “Location Factor From Base at Kuching City” for this tender is ____ % and is the percentage over all the items and rates as listed in this Schedule of Rates to be used for the purposes as stated in the tender documents. 3. Any attempt to amend / change / correct etc. this percentage by the tenderer shall cause the tender to be disqualified. JKR Sarawak December 2020
Transcript
Page 1: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

SCHEDULE OF RATES

FOR

ELECTRICAL INSTALLATION

WORKS IN SARAWAK 2020

Notes to tenderers:

1. This is only a cover page for this document. Please obtain the full set from the JKR Sarawak webpage.

2. The “Location Factor From Base at Kuching City” for this tender is ____ %

and is the percentage over all the items and rates as listed in this Schedule of Rates to be used for the purposes as stated in the tender documents.

3. Any attempt to amend / change / correct etc. this percentage by the

tenderer shall cause the tender to be disqualified.

JKR Sarawak

December 2020

Page 2: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

LOCATION FACTOR FROM BASE AT KUCHING CITY

(To be read together with the Rules of Determining the Location Factor)

Kuching

City

Padawan

Santubong

Bau

Lundu

Sematan

0%

2%

3%

5%

8%

9%

Serian

District

Tebedu

Siburan

Tebakang

Balai Ringin

5%

8%

3%

8%

8%

Samarahan

District

Simunjan

Sebuyau

Asajaya

Sadong Jaya

2%

12%

15%

10%

12%

Sri Aman

District

Lubok Antu

Lingga

Pantu

Engkilili

Skrang

15%

20%

20%

20%

18%

20%

Betong

District

Spaoh

Debak

Pusa

Beladin

Maludam

Saratok

Roban

Kabong

20%

20%

20%

21%

20%

22%

20%

20%

20%

Sarikei

District

Bintangor

Pakan

Selalang

Julau

Meluan

Ulu Entabai

Engkamop

Nanga Wak

Nanga Entabai

18%

18%

20%

20%

20%

22%

40%

25%

15%

14%

Sibu

District

Kem Bt. 10 & 14

Durin

Bawang Assan

Sungai Assan

Kanowit

Machan

Nibong Tada

Nanga Tada

Nanga Dap

Nanga Ngemah

Nanga Ngungun

Nanga Poi

Nanga Jagau

Selangau

Ulu Balingian

Arip

Stapang

Rassau

12%

13%

15%

13%

13%

16%

16%

15%

17%

20%

20%

20%

22%

40%

18%

20%

22%

16%

22%

Page 3: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

LOCATION FACTOR FROM BASE AT KUCHING CITY

(To be read together with the Rules of Determining the Location Factor)

Bintulu

District

Tatau

Sebauh

15%

20%

23%

Miri

City

Subis

Bekenu

Marudi

Long Lama

Beluru

15%

20%

15%

25%

40%

22%

Limbang District

Lawas

30%

28%

Mukah

District

Dalat

Oya

Igan

Balingian

Kuala Balingian

Semop

Matu

Betanak

Daro

Bruit

Tanjung Manis

20%

20%

20%

18%

23%

23%

30%

25%

30%

25%

30%

18%

Kapit

District

Song

Belaga

Sungai Asap

Bukit Mabong

30%

25%

70%

25%

40%

Page 4: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

RULES OF DETERMINING THE LOCAT ION FACTOR

1. The percentage (%) factors as stated are for those projects accessible by motorized vehicles

within fifteen kilometres (15 km) radius from the location shown.

2. Where the project site is beyond fifteen kilometres (15 km) radius of the above stated

locations, these additional percentage (%) factors shall be added on to those percentages

stated above:

Item Radius Percentage (%) Addition

(i) > 15 km to < 45 km 5%

(ii) > 45 km to < 90 km 10%

(iii) > 90 km to < 135 km 15%

(iv) > 135 km to < 180 km 20%

(v) > 180 km to < 220 km 25%

3. Where the project sites are accessible only by waterway:

Item Radius Percentage (%) Addition

(i) areas within 15 km radius 0%

(ii) areas within 30 km radius 5%

(iii) areas within 60 km radius 10%

(iv) areas within 90 km radius 15%

(v) areas within 120 km radius 20%

(vi) areas within 150 km radius 25%

4. Where the project sites can only be accessible by air, the location factor shall be doubled

over the value obtained from that by motorized vehicles.

5. Where the project sites can only be accessible by foot, the location factor shall be fifty

percent (50%) over the value obtained from that by motorized vehicles.

6. Where in determining the locations factor and two or more factors and radial distances are

equally applicable, the lower in each case shall be used.

7. Where in determining the location factor and two or more factors and radial distances by the

rules above whereby there can be a combination due to accessibility, say partly land and

partly waterway or partly waterway and partly by foot, there shall be a combination of the

rules according to the radial distance from the nearest locations stated above.

8. Where in determining the location factor and the site for the project lies within two radial

distances, the additional percentage (%) for the radial distance within which more than fifty

percent (50%) of the Site lies shall be used.

Page 5: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

SOR for Electrical Installation Works 2020 1

PREAMBLES

1. All rates given shall include supply, delivery, installation, testing and commissioning and shall include associated accessories and fitting.

2. Rate per point applies for the stated route length. For longer route length, the rate per metre, derived from the rate per point shall be used.

3. All rates shall be used and read together with the “Location Factor From Base at Kuching City”.

4. All rates herein have reasonably taken into account anticipated and calculated inflation and risk factors for the next two (2) years from the date of publication.

5. All descriptions are to be read with reference to the Standard Electrical Installation Specification (Latest Version) and the following:

(A) All rates herein shall be held to include for supply and delivery to site, wastage on materials, carriage and cartage, carrying in and return of empties, hoisting, setting, fitting and fixing in position, making good and all other labours and everything else necessary (including any custom duties, etc.) for the proper completion of each item and for establishment charges and profit.

(B) Rates for each item of paving shall be held to include for all rounded angles, arises and making good and any other sundry items of alike nature.

(C) Rates for mild steel tubing are to include for short running lengths, sockets, backnuts, elbows and bends.

Page 6: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 1 of 15

Item No.

Description Unit Rate (RM)

(A1)

1

(a)

(b)

(c)

2

(a)

3

(a)

(b)

4

(a)

(b)

(c)

5

(a)

(b)

(c)

(d)

(e)

6

(a)

GS Concealed conduit wiring c/w metal clad switch and socket plates and accessories : Wiring shall be run concealed, in Class ‘B’ galvanised

steel conduits and complete with GS conduit boxes let into cement or timber wall, or partition, together with all necessary metal clad lighting switch plates, switched socket plates, isolators and accessories. Wiring shall be 1.5 mm

2 PVC for fan and lighting points, 2.5 mm

2 PVC for 13A and 15A

switched sockets. 13A 3-pin switched socket points shall be wired in ring circuit(s). Lighting & Fan Points shall be terminated to ceiling rose. Accepted brands – Clipsal, PDL, MEM & JMAL approved brands. Lighting Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to

20 metres route length). 6A 1-way lighting point c/w switch. 6A 2-way lighting point c/w switch. 6A immediate lighting point c/w switch. Lighting Point : wired from nearest lighting point (sharing same switch) (up

to 4 metres route length). 6A 1-way lighting point. Fan Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to 10

metres route length). Ceiling fan point c/w 6A switch. Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and opening for fan. 13A 3-pin : Switched Socket Outlets :

13A 3-pin switched socket point in ring circuit : 1 – gang (up to 10 metres route length). 13A 3-pin switched socket point in ring circuit : 2 – gang (up to 10 metres route length). 15A 3-pin switched socket point (up to 15 metres route length). Isolator and Water Heater Points : (up to 15 metres route length).

Water heater point c/w 20A double pole switch with neon light indicator (4mm

2 PVC cable).

20A single phase isolator point c/w 4 mm

2 PVC cable.

30A single phase isolator point c/w 6 mm

2 PVC cable.

20A TPN isolator point c/w 4 mm

2 PVC cable.

30A TPN isolator point c/w 6 mm

2 PVC cable.

TV / Telephone Point : (up to 15 metres route length).

1-pair c/w socket and 2 x 0.63 mm

2 cable.

per point

per point

per point

per point

per fan point

per fan point

per 1-gang socket outlet pt.

per 2-gang

socket outlet pt.

per point

per point

per isolator point

per isolator point

per isolator point

per isolator point

per point

110.00

150.00

175.00

58.00

110.00

110.00

150.00

200.00

250.00

285.00

330.00

450.00

475.00

640.00

105.00

Page 7: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 2 of 15

Item No.

Description Unit Rate (RM)

6

(b)

(c)

7

(a)

(b)

(A2)

8

(a)

(b)

(c)

9

(a)

10

(a)

(b)

11

(a)

(b)

(c)

TV / Telephone Point : (up to 15 metres route length). (Cont’d)

2-pairs c/w socket and 4 x 0.63 mm

2 cable.

TV antennae point c/w 5c / 2v cable and TV socket. Miscellaneous Wiring Point : (up to 15 metres route length).

Single phase power supply to fire alarm control panel c/w 16A mcb and 2.5 mm

2 PVC cable.

Lighting point for “Emergency Lighting” or “Keluar Light” c/w 1.5 mm

2 PVC

cable. GS Surface conduit wiring c/w metal clad switch and socket plates and accessories : Wiring shall be run concealed, in Class ‘B’ galvanised steel

conduits and complete with GS conduit boxes, together with all necessary metal clad lighting switch plates, switched socket plates, isolators and accessories. Wiring shall be 1.5 mm

2 PVC for fan and lighting points, 2.5

mm2

PVC for 13A and 15A switched sockets. 13A 3-pin switched socket points shall be wired in ring circuit(s). Lighting & Fan Points shall be terminated to ceiling rose. Accepted brands – Clipsal, PDL, MEM & JMAL approved brands. Lighting Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to

20 metres route length). 6A 1-way lighting point c/w switch. 6A 2-way lighting point c/w switch. 6A immediate lighting point c/w switch. Lighting Point : wired from nearest lighting point (sharing same switch) (up

to 4 metres route length). 6A 1-way lighting point. Fan Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to 10

metres route length). Ceiling fan point c/w 6A switch. Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and opening for fan. 13A 3-pin : Switched Socket Outlets :

13A 3-pin switched socket point in ring circuit : 1 – gang (up to 10 metres route length). 13A 3-pin switched socket point in ring circuit : 2 – gang (up to 10 metres route length). 15A 3-pin switched socket point (up to 15 metres route length).

per point

per point

per point

per point

per point

per point

per point

per point

per fan point

per fan point

per 1-gang socket outlet point

per 2-gang socket

outlet point

per point

130.00

105.00

250.00

105.00

100.00

135.00

155.00

53.00

100.00

100.00

135.00

180.00

225.00

Page 8: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 3 of 15

Item No.

Description Unit Rate (RM)

12

(a)

(b)

(c)

(d)

(e)

13

(a)

(b)

(c)

14

(a)

(b)

(A3)

15

(a)

(b)

(c)

16

(a)

17

(a)

Isolator and Water Heater Points : (up to 15 metres route length).

Water heater point c/w 20A double pole switch with neon light indicator (4mm

2 PVC cable).

20A single phase isolator point c/w 4 mm

2 PVC cable.

30A single phase isolator point c/w 6 mm

2 PVC cable.

20A TPN isolator point c/w 4 mm2 PVC cable.

30A TPN isolator point c/w 6 mm2 PVC cable.

TV / Telephone Point : (up to 15 metres route length).

1 – pair c/w socket and 2 x 0.63 mm

2 cable.

2 – pairs c/w socket and 4 x 0.63 mm

2 cable.

TV antennae point c/w 5c / 2v cable and TV socket. Miscellaneous Wiring Point : (up to 15 metres route length).

Single phase power supply to fire alarm control panel c/w 16A mcb and 2.5 mm

2 PVC cable.

Lighting point for “Emergency Lighting” or “Keluar Light” c/w 1.5 mm

2 PVC

cable. GS Concealed conduit wiring c/w plastic moulded switch and socket plates and accessories : Wiring shall be run concealed, in Class ‘B’ galvanized steel conduits and complete with GS conduit boxes let into cement or timber wall, or partition, together with all necessary PVC moulded lighting switch plates, switched socket plates and accessories. Wiring shall be 1.5 mm

2 PVC for fan and lighting points, 2.5 mm

2 PVC for 13A and 15A

switched sockets. 13A 3-pin switched socket points shall be wired in ring circuit/s. Lighting & Fan Points shall be terminated to ceiling rose. Accepted brands – Clipsal, PDL, MEM & JMAL approved brands. Lighting Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to

20 metres route length). 6A 1-way lighting point c/w switch. 6A 2-way lighting point c/w switch. 6A immediate lighting point c/w switch. Lighting Point : wired from nearest lighting point (sharing same switch) (up

to 4 metres route length). 6A 1-way lighting point. Fan Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to 10

metres route length). Ceiling fan point c/w 6A switch.

per point

per isolator point

per isolator point

per isolator point per isolator point

per point

per point

per point

per point

per point

per point

per point

per point

per point

per fan point

255.00

295.00

405.00

430.00

580.00

95.00

115.00

95.00

225.00

95.00

105.00

145.00

165.00

55.00

105.00

Page 9: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 4 of 15

Item

No. Description Unit Rate (RM)

17

(b)

18

(a)

(b)

(c)

19

(a)

(b)

(c)

(d)

(e)

20

(a)

(b)

(c)

21

(a)

(b)

(A4)

22

(a)

Fan Point : wired from nearest switch c/w 1.5 mm2 PVC cable (up to 10

metres route length). (Cont’d)

Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and

opening for fan.

13A 3-pin : Switched Socket Outlets :

13A 3-pin switched socket point in ring circuit :

1-gang (up to 10 metres route length).

13A 3-pin switched socket point in ring circuit :

2-gang (up to 10 metres route length).

15A 3-pin switched socket point (up to 15 metres route length).

Isolator and Water Heater Points : (up to 15 metres route length).

Water heater point c/w 20A double pole switch with neon light indicator

(4 mm2

PVC cable).

20A single phase isolator point c/w 4 mm2 PVC cable.

30A single phase isolator point c/w 6 mm2 PVC cable.

20A TPN isolator point c/w 4 mm2 PVC cable.

30A TPN isolator point c/w 6 mm2 PVC cable.

TV / Telephone Point : (up to 15 metres route length).

1 – pair c/w socket and 2 x 0.63 mm2 cable.

2 – pairs c/w socket and 4 x 0.63 mm2 cable.

TV antennae point c/w 5c / 2v cable and TV socket.

Miscellaneous Wiring Point :(up to 15 metres route length).

Single phase power supply to fire alarm control panel c/w 16A mcb and 2.5

mm2 PVC cable.

Lighting point for “Emergency Lighting” or “Keluar Light” c/w 1.5 mm2 PVC

cable.

uPVC Concealed conduit wiring c/w plastic moulded switch and socket plates and accessories : Wiring shall be run surface in High

Impact / uPVC conduit and complete with PVC conduit boxes together with all necessary PVC lighting switch plates, switched socket plates, isolator and accessories. Wiring shall be 1.5 mm

2 PC for fan and lighting points,

2.5 mm2 PVC for 13A and 15A switched sockets. Lighting & Fan Points

shall be terminated to ceiling rose. Accepted brands – Clipsal, PDL, MEM & JMAL approved brands. Lighting Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to

20 metres route length). 6A 1-way lighting point c/w switch

per fan point

per 1-gang

socket outlet pt.

per 2-gang

socket outlet pt.

per point

per point

per isolator point

per isolator point

per isolator point

per isolator point

per point

per point

per point

per point

per point

per point

105.00

140.00

190.00

240.00

270.00

310.00

430.00

450.00

608.00

100.00

120.00

100.00

240.00

100.00

95.00

Page 10: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 5 of 15

Item No.

Description Unit Rate (RM)

22

(b)

(c)

23

(a)

24

(a)

(b)

25

(a)

(b)

(c)

26

(a)

(b)

(c)

(d)

(e)

27

(a)

(b)

(c)

28

(a)

(b)

Lighting Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to

20 metres route length). (Cont’d) 6A 2-way lighting point c/w switch 6A immediate lighting point c/w switch Lighting Point : wired from nearest lighting point (sharing same switch)

(up to 4 metres route length). 6A 1-way lighting point. Fan Point : wired from nearest switch c/w 1.5 mm

2 PVC cable (up to 10

metres route length). Ceiling fan point c/w 6A switch. Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and opening for fan. 13A 3-pin : Switched Socket Outlets :

13A 3 – pin switched socket point in ring circuit : 1 – gang (up to 10 metres route length). 13A 3 – pin switched socket point in ring circuit : 2 – gang (up to 10 metres route length). 15A 3 – pin switched socket point (up to 15 metres route length). . Isolator and Water Heater Points : (up to 15 metres route length).

Water heater point c/w 20A double pole switch with neon light indicator (4 mm

2 PVC cable).

20A single phase isolator point c/w 4 mm

2 PVC cable.

30A single phase isolator point c/w 6 mm

2 PVC cable.

20A TPN isolator point c/w 4 mm

2 PVC cable.

30A TPN isolator point c/w 6 mm

2 PVC cable.

TV / Telephone Point : (up to 15 metres route length).

1 – pair c/w socket and 2 x 0.63 mm

2 cable.

2 – pairs c/w socket and 4 x 0.63 mm

2 cable.

TV antennae point c/w 5c / 2v cable and TV socket. Miscellaneous Wiring Point : (up to 15 metres route length).

Single phase power supply to fire alarm control panel c/w 16A mcb and 2.5 mm

2 PVC cable

Lighting point for “Emergency Lighting” or “Keluar Light” c/w 1.5 mm

2 PVC

cable

per point

per point

per point

per fan point

per fan point

per 1-gang socket

outlet point

per 2-gang socket outlet point

per point

per point

per isolator point

per isolator point

per isolator point

per isolator point

per point

per point

per point

per point

per point

130.00

150.00

50.00

95.00

95.00

130.00

175.00

219.00

249.00

289.00

399.00

419.00

569.00

90.00

110.00

90.00

215.00

90.00

Page 11: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 6 of 15

Item No.

Description Unit Rate (RM)

(A5)

29

(a)

(b)

(c)

30

(a)

31

(a)

(b)

32

(a)

(b)

(c)

33

(a)

(b)

(c)

(d)

(e)

34

(a)

(b)

uPVC Surface conduit wiring c/w plastic moulded switch and socket plates and accessories : Wiring shall be run surface in High Impact /

uPVC conduits and complete with PVC conduit boxes together with all necessary PVC lighting switch plates, switched socket plates, isolator and accessories. Wiring shall be 1.5 mm

2 PVC for fan and lighting points, 2.5

mm2 PVC for 13A and 15A switched sockets. Lighting & Fan Points shall

be terminated to ceiling rose. Accepted brands – Clipsal, PDL, MEM & JMAL approved brands. Lighting Point : wired from nearest switch c/w 1.5 mm

2 PVC cable

(up to 20 metres route length). 6A 1-way lighting point c/w switch. 6A 2-way lighting point c/w switch. 6A immediate lighting point c/w switch. Lighting Point : wired from nearest lighting point (sharing same switch)

(up to 4 metres route length). 6A 1-way lighting point. Fan Point: wired from nearest switch c/w 1.5 mm

2 PVC cable (up to 10

metres route length). Ceiling fan point c/w 6A switch. Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and opening for fan. 13A 3-pin : Switched Socket Outlets :

13A 3-pin switched socket point in ring circuit : 1 – gang (up to 10 metres route length). 13A 3-pin switched socket point in ring circuit : 2 – gang (up to 10 metres route length). 15A 3-pin switched socket point (up to 15 metres route length). Isolator and Water Heater Points : (up to 15 metres route length).

Water heater point c/w 20A double pole switch with neon light indicator (4 mm

2 PVC cable).

20A single phase isolator point c/w 4 mm

2 PVC cable.

30A single phase isolator point c/w 6 mm

2 PVC cable.

20A TPN isolator point c/w 4 mm

2 PVC cable.

30A TPN isolator point c/w 6 mm

2 PVC cable.

TV/Telephone Point :(up to 15 metres route length).

1 – pair c/w socket and 2 x 0.63mm2

cable. 2 – pairs c/w socket and 4 x 0.63mm

2 cable.

per point

per point

per point

per point

per fan point

per fan point

per 1-gang socket

outlet point

per 2-gang socket outlet point

per point

per point

per isolator point

per isolator point

per isolator point

per isolator point

per point

per point

85.00

117.00

135.00

45.00

85.00

85.00

117.00

157.00

198.00

224.00

260.00

359.00

377.00

512.00

81.00

99.00

Page 12: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 7 of 15

Item No.

Description Unit Rate (RM)

34

(c)

35

(a)

(b)

(A6)

36

(a)

(b)

(c)

37

(a)

38

(a)

(b)

39

(a)

(b)

(c)

40

(a)

(b)

TV/Telephone Point : (up to 15 metres route length). (Cont’d)

TV antennae point c/w 5c / 2v cable and TV socket. Miscellaneous Wiring Point : (up to 15 metres route length).

Single phase power supply to fire alarm control panel c/w 16A mcb and 2.5 mm

2 PVC cable.

Lighting point for “Emergency Lighting” or “Keluar Light” c/w 1.5 mm

2 PVC

cable. Surface Wiring : Wiring shall be run surface on batten wood complete with

all necessary PVC moulded conduit boxes, lighting switch plates, 13A or 15A switched socket plates and accessories. Wiring shall be 1.5 mm

2

PVC/PVC for fan and lighting points, 2.5 mm2 PVC/PVC for 13A and 15A

switched sockets. 13A 3-pin switched socket points shall be wired in ring circuit/s. Lighting & Fan Points shall be terminated to ceiling rose. Accepted brands – Clipsal, PDL, MEM & JMAL approved brands. Lighting Point : wired from nearest switch c/w 1.5 mm

2 PVC/PVC cable

(up to 20 metres route length). 6A 1-way lighting point c/w switch. 6A 2-way lighting point c/w switch. 6A immediate lighting point c/w switch. Lighting Point : wired from nearest lighting point (sharing same switch)

(up to 4 metres route length). 6A 1-way lighting point. Fan Point: wired from nearest switch c/w 1.5 mm

2 PVC/PVC cable

(up to 10 metres route length). Ceiling fan point c/w 6A switch. Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and opening for fan. 13A 3-pin : Switched Socket Outlets :

13A 3-pin switched socket point in ring circuit : 1 – gang (up to 10 metres route length). 13A 3-pin switched socket point in ring circuit : 2 – gang (up to 10 metres route length). 15A 3-pin switched socket point (up to 15 metres route length). Isolator and Water Heater Points : (up to 15 metres route length).

Water heater point c/w 20A double pole switch with neon light indicator (4 mm

2 PVC/PVC cable).

20A single phase isolator point c/w 4 mm

2 PVC/PVC cable.

per point

per point

per point

per point

per point

per point

per point

per fan point

per fan point

per 1-gang socket

outlet point

per 2-gang socket outlet point

per point

per point

per isolator point

81.00

193.00

81.00

81.00

111.00

128.00

43.00

81.00

81.00

111.00

149.00

188.00

213.00

247.00

Page 13: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

A GENERAL WIRING

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 8 of 15

Item No.

Description Unit Rate (RM)

40

(c)

(d)

(e)

41

(a)

(b)

(c)

42

(a)

(b)

(A7)

43

(a)

(b)

(c)

(d)

44

(a)

(b)

Isolator and Water Heater Points : (up to 15 metres route length).

(Cont’d) 30A single phase isolator point c/w 6 mm

2 PVC/PVC cable.

20A TPN isolator point c/w 4 mm

2 PVC/PVC cable.

30A TPN isolator point c/w 6 mm

2 PVC/PVC cable.

TV / Telephone Point : (up to 15 metres route length).

1 – pair c/w socket and 2 x 0.63 mm

2 cable.

2 – pairs c/w socket and 4 x 0.63 mm

2 cable.

TV antennae point c/w 5c / 2v cable and TV socket. Miscellaneous Wiring Point : (up to 15 metres route length).

Single phase power supply to fire alarm control panel c/w 16A mcb and 2.5 mm

2 PVC/PVC cable.

Lighting point for “Emergency Lighting” or “Keluar Light” c/w 1.5 mm

2

PVC/PVC cable. Others Wiring. Main and Sub-mains Wiring : from SESCO supply intake to distribution

boards / consumer units, through meter and cut-outs, using surface wiring. 1-phase 2 x 16 mm

2 1-core PVC insulated and sheathed cables.

1-phase 2 x 25 mm

2 1-core PVC insulated and sheathed cables.

3-phase 4 x 16 mm

2 1-core PVC insulated and sheathed cables.

3-phase 4 x 25 mm

2 1-core PVC insulated and sheathed cables.

Earthing Leads: from distribution board to earth electrode-green PVC

insulated copper cable protected by Class ‘B’ galvanised steel conduits to be installed below surface of hard-standing, cement floor, corridor, apron, etc. (up to 10 metres route length). 16 mm

2 PVC insulated.

25 mm

2 PVC insulated.

per isolator point

per isolator point

per isolator point

per point

per point

per point

per point

per point

per meter

per meter

per meter

per meter

per lot

per lot

341.00

358.00

486.00

77.00

94.00

77.00

183.00

77.00

34.00

45.00

56.00

79.00

281.00

359.00

Page 14: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

B LIGHTING FITTINGS, FANS AND ACCESSORIES

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 9 of 15

Item No.

Description Unit Rate (RM)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

Accessories : Cost for extractor fan hole openings in brick or wooden

walls shall include cost of making the hole together with 2” x 4” hardwood frame. Size of opening shall be appropriate for the diameter of fans indicated. Installation of fan hook from cement floor slab. Installation of fan hook from timber floor joist. Extractor fan hole opening in brick wall for extractor fan of diameter from 400mm to 500mm (16” to 20”). Extractor fan hole opening in brick wall for extractor fan of diameter from 200mm to 350mm (8” to 14”). Extractor fan hole opening in wooden wall for extractor fan of diameter from 400mm to 500mm (16” to 20”). Extractor fan hole opening in wooden wall for extractor fan of diameter from 200mm to 350mm (8” to 14”). Extractor fan hole opening in glass panel for extractor fan of diameter from 200mm to 350mm (8” to 14”). Fans : Cost includes supply and installation of fittings. Ceiling fans and

oscillating fans shall have individual 3-speed (low/medium/high) regulators. Wall fans shall feature pull cord oscillation control and 3-speed (low/medium/high) regulators. Ceiling fans shall have safety steel suspension wire and safe power disconnection feature. Cost of making fan hole opening is priced separately. Accepted brands – Khind, National, KDK, Sanyo & JMAL approved brands.

Ceiling fan 1,520 mm (60”) diameter sweep. Ceiling mount oscillating fan – 500 mm (20”) dia. Ceiling mount oscillating fan – 400 mm (16”) dia. Wall mount fan – 500 mm (20”) diameter. Wall mount fan – 400 mm (16”) diameter. Extractor fan – 500 mm (20”) diameter. Extractor fan – 400 mm (16”) diameter. Extractor fan – 350 mm (14”) diameter. Extractor fan – 300 mm (12”) diameter. Extractor fan – 200 mm (8”) diameter.

per unit

per unit

per no.

per no.

per no.

per no.

per no.

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

36.00

29.00

219.00

180.00

148.00

129.00

165.00

183.00

365.00

292.00

292.00

258.00

292.00

247.00

213.00

191.00

165.00

Page 15: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

B LIGHTING FITTINGS, FANS AND ACCESSORIES

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 10 of 15

Item No.

Description Unit Rate (RM)

18

(a)

(b)

(c)

(d)

(e)

(f)

(g)

19

(a)

(b)

(c)

(d)

(e)

(f)

20

(a)

(b)

(c)

21

(a)

(b)

(c)

Fluorescent Fittings : All fluorescent fittings shall be complete with low

loss polyester resin impregnated ballast of loss not exceeding 6.5 watts, power factor correction capacitor to correct to power factor of not less than 0.85, starter, fluorescent tubes and holders. Cost includes supply and installation. Acceptable brands – LHL, Britelite, Davis, Jetlite, National, GEC, Philip, Thorn & JMAL approved brands. (T8 Fluorescent) Channel Fluorescent Fitting – 1 x 18W / 36 W Surface Mount.

1 x 18 watt bare channel fluorescent fitting. 1 x 18 watt channel fluorescent fitting c/w wire guard. 1 x 36 watt bare channel fluorescent fitting. 1 x 36 watt bare channel fluorescent fitting c/w metal angle reflector. 1 x 36 watt bare channel fluorescent fitting c/w suspension rod. 1 x 36 watt channel fluorescent fitting c/w wire guard. 1 x 36 watt channel fluorescent fitting c/w wire guard and suspension rod. Channel Fluorescent Fitting – 2 x 36 W Surface Mount.

2 x 36 watt bare channel fluorescent fitting. 2 x 36 watt channel fluorescent fitting c/w suspension rod. 2 x 36 watt bare channel fluorescent fitting c/w diakon diffuser. 2 x 36 watt bare channel fluorescent fitting c/w diakon diffuser and suspension rod. 2 x 36 watt bare channel fluorescent fitting c/w metal trough reflectors. 2 x 36 watt channel fluorescent fitting c/w metal trough reflectors and suspension rod. Modular Type Fluorescent Fittings – Recessed Fittings.

2 x 18 watt modular recessed (2’ x 2’) fluorescent fitting c/w aluminium parabolic reflector and baffles. 2 x 36 watt modular recessed (2’ x 4’) fluorescent fitting c/w aluminium parabolic reflector and baffles. 3 x 36 watt modular recessed (2’ x 4’) fluorescent fitting c/w aluminium parabolic reflector and louvers. Modular Type Fluorescent Fittings – Surface Fittings.

2 x 18 watt modular recessed (2’ x 2’) fluorescent fitting c/w aluminium parabolic reflector and baffles. 2 x 36 watt modular recessed (2’ x 4’) fluorescent fitting c/w aluminium parabolic reflector and baffles. 3 x 36 watt modular recessed (2’ x 4’) fluorescent fitting c/w aluminium parabolic reflector and louvers.

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

35.00

64.00

41.00

76.00

82.00

71.00

101.00

71.00

94.00

106.00

129.00

100.00

135.00

165.00

200.00

242.00

165.00

200.00

229.00

Page 16: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

B LIGHTING FITTINGS, FANS AND ACCESSORIES

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 11 of 15

Item No.

Description Unit Rate (RM)

22

(a)

(b)

(c)

(d)

23

(a)

(b)

(c)

(d)

24

(a)

(b)

(c)

(d)

25

(a)

(b)

(c)

(d)

(e)

Self-contained Modular Type Fluorescent Fittings c/w Battery & Charger.

2 x 18 watt modular recessed (2’ x 2’) fluorescent fitting c/w aluminium parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid battery, charger and control unit. 2 x 36 watt modular recessed (2’ x 4’) fluorescent fitting c/w aluminium parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid battery, charger and control unit. 2 x 18 watt modular surface (2’ x 2’) fluorescent fitting c/w aluminium parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid battery, charger and control unit. 2 x 18 watt modular recessed (2’ x 4’) fluorescent fitting c/w aluminium parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid battery, charger and control unit. Fluorescent Fittings : All fluorescent fittings shall be complete with low

loss polyester resin impregnated ballast of loss not exceeding 6.5 watts, power factor correction capacitor to correct to power factor of not less than 0.85, starter, fluorescent tubes and holders. Cost includes supply and installation. Acceptable brands – LHL, Philip & JMAL approved brands. (T5 Fluorescent) Channel Fluorescent Fitting – 14W / 28W Surface Mount.

1 x 14 watt.

2 x 14 watt. 1 x 28 watt. 2 x 28 watt. Channel Fluorescent Fitting – 14W / 28W Surface Mount c/w Metal Trough Reflector.

1 x 14 watt.

2 x 14 watt. 1 x 28 watt. 2 x 28 watt. Modular Type Fluorescent Fitting c/w Aluminium Parabolic Reflector and Baffles.

2 x 14 watt (modular : 600mm x 600mm). 3 x 14 watt (modular : 600mm x 600mm). 4 x 14 watt (modular : 600mm x 600mm). 2 x 28 watt (modular : 300mm x 1200mm). 2 x 28 watt (modular : 600mm x 1200mm).

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

343.00

425.00

342.00

425.00

65.00

85.00

82.00

108.00

85.00

120.00

95.00

135.00

200.00

266.00

294.00

228.00

244.00

Page 17: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

B LIGHTING FITTINGS, FANS AND ACCESSORIES

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 12 of 15

Item No.

Description Unit Rate (RM)

25

(f)

(g)

26

(a)

(b)

(c)

(d)

(e)

(f)

(g)

(h)

(i)

27

(a)

28

(a)

(b)

(c)

(d)

(e)

Modular Type Fluorescent Fitting c/w Aluminium Parabolic Reflector and Baffles. (Cont’d)

3 x 28 watt (modular : 600mm x 1200mm) 4 x 28 watt (modular : 600mm x 1200mm) Miscellaneous Lighting Fittings : Cost includes supply and installation of

fittings. Installation for floodlight fittings is in reference to standard installation on walls accessible by ladder. Accepted brands – for flood lights (Nikkon, Thorn, Philips & JMAL approved brands) & for others (JMAL approved brands). Emergency Light / KELUAR Sign Fittings : self contained c/w sealed 3-

hr maintenance free sealed lead-acid battery, charger and control unit c/w trickle charging & over-charge protection. Self contained 2 x 8 watts emergency lighting fitting. ‘KELUAR’ sign – fluorescent type, single sided.

‘KELUAR’ sign – fluorescent type, double sided. ‘KELUAR’ c/w direction signage – single sided fluorescent type. ‘KELUAR’ c/w direction signage – double sided fluorescent type. ‘KELUAR’ sign – LED type, single sided. ‘KELUAR’ sign – LED type, double sided.

‘KELUAR’ c/w direction signage – single sided LED type.

‘KELUAR’ c/w direction signage – double sided LED type. Lamp-Shade c/w Incandescent Lamp.

Coolicon lamp shade, lamp holder c/w 40W, 60W or 100W incandescent lamp. Flood-Light / Spot-Light Fittings.

Outdoor type spot lighting c/w metal lamp holder and PAR 38 150W lamp of various colours. Outdoor type metal halide floodlight fittings c/w 400W lamp, control gear and power factor correction capacitor. Outdoor type metal halide floodlight fittings c/w 250W lamp, control gear and power factor correction capacitor Outdoor type high pressure sodium floodlight fittings c/w 400W lamp, control gear and power factor correction capacitor. Outdoor type high pressure sodium floodlight fittings c/w 250W lamp, control gear and power factor correction capacitor.

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

per unit

324.00

358.00

129.00

189.00

234.00

194.00

247.00

194.00

206.00

212.00

225.00

18.00

71.00

543.00

472.00

566.00

483.00

Page 18: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

B LIGHTING FITTINGS, FANS AND ACCESSORIES

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 13 of 15

Item

No. Description Unit Rate (RM)

29

(a)

(b)

30

(a)

(b)

(c)

(d)

31

(a)

(b)

(c)

(d)

(e)

(f)

(g)

(h)

(i)

32

(a)

(b)

(c)

(d)

(e)

(f)

Bulkhead Fittings.

Bulkhead fitting – pressure die-cast aluminium alloy type c/w 40W, 60W or

100W incandescent lamp, glass cover and wire guard.

Bulkhead fitting – plastic die-cast type c/w 40W, 60W or 100W

incandescent lamp, plastic cover and wire guard.

LED Lighting Fittings : Cost includes supply and installation of fittings.

Installation for LED light fittings is in reference to standard installation on

walls/ceilings complete with strong bracket/metal wire/support and

accessible by ladder. Accepted brands – for LED lights (Nikkon, Thorn,

Philips, Osram, SAG, Davis, Panasonic).

LED Bulb.

LED Bulb 7W, min. (8000 hours, 3000 K)

LED Bulb 11W, min. (8000 hours, 3000 K)

LED Bulb 13W, min. (8000 hours, 3000 K)

LED Bulb 15W, min. (8000 hours, 3000 K)

LED Downlight.

LED Downlight : 6W, min. (3000 K, 600 lm)

LED Downlight : 9W, min. (3000 K, 800 lm)

LED Downlight : 10W, min. (3000 K, 800 lm)

LED Downlight : 13W, min. (3000 K, 1000 lm)

LED Downlight : 15W, min. (3000 K, 1000 lm)

LED Downlight : 18W, min. (3000 K, 1500 lm)

LED Downlight : 25W, min. (3000 K, 2500 lm)

LED Downlight : 30W, min. (3000 K, 3000 lm)

LED Downlight : 35W, min. (3000 K, 3200 lm)

LED Floodlight.

LED Floodlight : 30W, min. (3000 K, 2000 lm), IP65

LED Floodlight : 50W, min. (3000 K, 4000 lm), IP65

LED Floodlight : 70W, min. (3000 K, 5000 lm), IP65

LED Floodlight : 100W, min. (3000 K, 7000 lm), IP65

LED Floodlight : 150W, min. (3000 K, 11000 lm), IP65

LED Floodlight : 200W, min. (3000 K, 15000 lm), IP65

per unit

per unit

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

94.00

47.00

10.00

14.00

16.00

19.00

131.00

142.00

145.00

158.00

166.00

173.00

191.00

250.00

285.00

63.00

95.00

136.00

311.00

388.00

569.00

Page 19: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

C DISTRIBUTION BOARDS & CONSUMER UNITS

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 14 of 15

Item No.

Description Unit Rate (RM)

1

(a)

(b)

(c)

(d)

(e)

(f)

2

(a)

(b)

(c)

(d)

(e)

(f)

3

(a)

(b)

(c)

(d)

(e)

(f)

4

(a)

(b)

Distribution Boards & Consumer Units : Distribution boards and

consumer units shall be metal clad type c/w isolator, Type-A - residual current circuit breaker (RCCB) and assortment of miniature circuit breakers (MCB). Isolators and RCCB shall be double pole and four pole respectively for single phase and three phase units. Isolators shall be rated at 60A min. Miniature circuit breakers shall be single pole 6A, 15A or 32A as required, of minimum breaking capacity 5 kA, and tripping curve Type B. Comb-type busbars are not accepted. Units shall feature DIN rail mounting for plug-in, wired-out MCB. Accepted brands – MEM, Hager, L&T, LKH & JMAL approved brands. Single Phase Consumer Units / Distribution Boards.

4 – way (Type A - RCCB : 40A, 30 mA sensitivity). 4 – way (Type A - RCCB : 60A, 30 mA sensitivity). 6 – way (Type A - RCCB : 40A, 30 mA sensitivity). 6 – way (Type A - RCCB : 60A, 30 mA sensitivity). 8 – way (Type A - RCCB : 40A, 30 mA sensitivity). 8 – way (Type A - RCCB : 60A, 30 mA sensitivity). Single Phase Consumer Units / Distribution Boards.

4 – way (Type A - RCCB : 40A, 100 mA sensitivity). 4 – way (Type A - RCCB : 60A, 100 mA sensitivity). 6 – way (Type A - RCCB : 40A, 100 mA sensitivity). 6 – way (Type A - RCCB : 60A, 100 mA sensitivity). 8 – way (Type A - RCCB : 40A, 100 mA sensitivity). 8 – way (Type A - RCCB : 60A, 100 mA sensitivity). Three Phase Distribution Boards.

4 – way (Type A - RCCB : 40A, 30 mA sensitivity). 4 – way (Type A - RCCB : 60A, 30 mA sensitivity). 6 – way (Type A - RCCB : 40A, 30 mA sensitivity). 6 – way (Type A - RCCB : 60A, 30 mA sensitivity). 8 – way (Type A - RCCB : 40A, 30 mA sensitivity). 8 – way (Type A - RCCB : 60A, 30 mA sensitivity). Three Phase Distribution Boards.

4 – way (Type A - RCCB : 40A, 100 mA sensitivity). 4 – way (Type A - RCCB : 60A, 100 mA sensitivity).

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

per set

370.00

425.00

460.00

515.00

535.00

595.00

315.00

370.00

405.00

461.00

480.00

540.00

1,125.00

1,185.00

1,230.00

1,265.00

1,425.00

1,560.00

1,070.00

1,130.00

Page 20: SCHEDULE OF RATES FOR ELECTRICAL INSTALLATION WORKS …

C DISTRIBUTION BOARDS & CONSUMER UNITS

SOR ELECTRICAL INSTALLATION WORKS 2020/Page 15 of 15

Item No.

Description Unit Rate (RM)

4

(c)

(d)

(e)

(f)

Three Phase Distribution Boards. (Cont’d)

6 – way (Type A - RCCB : 40A, 100 mA sensitivity). 6 – way (Type A - RCCB : 60A, 100 mA sensitivity). 8 – way (Type A - RCCB : 40A, 100 mA sensitivity). 8 – way (Type A - RCCB : 60A, 100 mA sensitivity).

per set

per set

per set

per set

1,175.00

1,210.00

1,370.00

1,505.00


Recommended