GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS
Transcript
Page 1: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

GAS CHROMATOGRAPHYInnovation with Integrity

The Gas Chromatographers’ Detector

SCION SQ GC-MS

Bruker Daltonik GmbH

Bremen · GermanyPhone +49 (0)421-2205-0 Fax +49 (0)421-2205-103 [email protected]

Bruker Daltonics Inc.

Billerica, MA · USA Fremont, CA · USAPhone +1 (978) 663-3660 Phone +1 (510) 683-4300 Fax +1 (978) 667-5993 Fax +1 (510) 490-6586 [email protected] [email protected]

www.bruker.com/scion

Page 2: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

The innovative philosophy of Bruker combined with a legacy of reliability, has resulted in a new industry standard for the gas chromatography single quadrupole mass detector. By actively listening to GC users all over the world, Bruker has delivered a solution focused on getting the job done from the users perspective. The SCION SQ detector is designed to meet your requirements – reliable performance, easy to use and maintain, and a small instrument footprint that saves valuable bench space.

Introducing the SCION SQ™ GC-MS

The SCION SQ is designed to analyze thousands of samples from complex matrices. With an upper mass limit of m/z 1200, it is purposefully matched for any GC application. The innovative ‘Lens-Free’ design gives you unmat-ched stability, which combined with the robustness of the ion source, delivers ultra-high sensitivity on a routine basis. Additionally, every EI system is shipped “CI ready” for easy future upgrade to CI to meet your requirement for versatility.

Example of flexible and powerful library search showing matching of sample peak to o,p’-DDE in the NIST library

Enhanced Library Searching through Cleaner EI Spectra

One-click search of multiple spectral databases

User-created spectral libraries and full support of spectral libraries such as NIST, Wiley, and Pfleger/Maurer/ Weber (PMW)

Adjustable spectral search parameters to streamline library searches

Flexible and easy to use

SCION SQ GC-MS BenefitsEasy to use• Simple tuning due to “lens-free”

ion-path design• No multiplier calibration required.

Robust • A heated inert ion source that

requires less frequent cleaning

Sensitive• Active-Focusing q0 uses He molecules

to focus ions

Page 3: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

The innovative philosophy of Bruker combined with a legacy of reliability, has resulted in a new industry standard for the gas chromatography single quadrupole mass detector. By actively listening to GC users all over the world, Bruker has delivered a solution focused on getting the job done from the users perspective. The SCION SQ detector is designed to meet your requirements – reliable performance, easy to use and maintain, and a small instrument footprint that saves valuable bench space.

Introducing the SCION SQ™ GC-MS

The SCION SQ is designed to analyze thousands of samples from complex matrices. With an upper mass limit of m/z 1200, it is purposefully matched for any GC application. The innovative ‘Lens-Free’ design gives you unmat-ched stability, which combined with the robustness of the ion source, delivers ultra-high sensitivity on a routine basis. Additionally, every EI system is shipped “CI ready” for easy future upgrade to CI to meet your requirement for versatility.

Example of flexible and powerful library search showing matching of sample peak to o,p’-DDE in the NIST library

Enhanced Library Searching through Cleaner EI Spectra

One-click search of multiple spectral databases

User-created spectral libraries and full support of spectral libraries such as NIST, Wiley, and Pfleger/Maurer/ Weber (PMW)

Adjustable spectral search parameters to streamline library searches

Flexible and easy to use

SCION SQ GC-MS BenefitsEasy to use• Simple tuning due to “lens-free”

ion-path design• No multiplier calibration required.

Robust • A heated inert ion source that

requires less frequent cleaning

Sensitive• Active-Focusing q0 uses He molecules

to focus ions

Page 4: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

Linearity, Sensitivity, and Spectral Matching Using the SCION SQ for US EPA Methods

Pesticide Residue Analysis in QuEchERS Extract

Why Choose the SCION SQ?

The SCION SQ shares key innovations with the SCION TQ triple quadrupole GC-MS/MS system. As a result, the SCION SQ GC-MS system delivers exceptional performance for a single quadrupole instrument: cleaner spectra, virtually zero neutral noise, and ultra-high sensitivity. A high-capacity turbo pump comes standard with every SCION SQ GC-MS, making it versatile to meet your most demanding need for high carrier gas flow or the use of hydrogen carrier gas. As a result, it is easily upgradable to CI without costly exchange of the turbo pump.

Active Focusing q0• He-molecules introduced into

the curved q0 focus the ion beam for high sensitivity

• Heated for maximum robustness

• 90° curve eliminates neutral noise

Ion Source• Dual Filament with Rebound

Electron Beam technology• Plug’N’Play for fast exchanges• Inert for high robustness

Lens-Free Ion Path• Simplifies tuning • Increases mass stability• Reduces maintenance

Extended Dynamic Range (EDR) Detector• Integrated-Quad design for

maximum sensitivity• Superior negative ion

performance• No multiplier calibration

required

TIC chromatogram of a 5mL water sample containing 84 VOCs at 10 ug/L (ppb) by US EPA Method 524.3

Excellent linearity of Tetrachloroethylene from 0.1 to 40 ppb with the purge-and-trap (A), good sensitivity (B) high quality spectra (C) down to 0.1 ppb level and showing good match to the NIST library (D).

A)C)

B) D)

TIC Chromatogram

Page 5: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

Linearity, Sensitivity, and Spectral Matching Using the SCION SQ for US EPA Methods

Pesticide Residue Analysis in QuEchERS Extract

Why Choose the SCION SQ?

The SCION SQ shares key innovations with the SCION TQ triple quadrupole GC-MS/MS system. As a result, the SCION SQ GC-MS system delivers exceptional performance for a single quadrupole instrument: cleaner spectra, virtually zero neutral noise, and ultra-high sensitivity. A high-capacity turbo pump comes standard with every SCION SQ GC-MS, making it versatile to meet your most demanding need for high carrier gas flow or the use of hydrogen carrier gas. As a result, it is easily upgradable to CI without costly exchange of the turbo pump.

Active Focusing q0• He-molecules introduced into

the curved q0 focus the ion beam for high sensitivity

• Heated for maximum robustness

• 90° curve eliminates neutral noise

Ion Source• Dual Filament with Rebound

Electron Beam technology• Plug’N’Play for fast exchanges• Inert for high robustness

Lens-Free Ion Path• Simplifies tuning • Increases mass stability• Reduces maintenance

Extended Dynamic Range (EDR) Detector• Integrated-Quad design for

maximum sensitivity• Superior negative ion

performance• No multiplier calibration

required

TIC chromatogram of a 5mL water sample containing 84 VOCs at 10 ug/L (ppb) by US EPA Method 524.3

Excellent linearity of Tetrachloroethylene from 0.1 to 40 ppb with the purge-and-trap (A), good sensitivity (B) high quality spectra (C) down to 0.1 ppb level and showing good match to the NIST library (D).

A)C)

B) D)

TIC Chromatogram

Page 6: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

The perfect addition for the SCION TQ PTV inlet is the back flush option. Complex sample matrix can quickly ruin the chromatographic performance of your GC column. However, the PTV with Bruker’s “backflush” technique can reliably divert the higher boiling sample matrix away from the column. The benefits of this accessory are many: Run more samples per day - decrease analysis

times as the heavy components are quickly eliminated

Save time by eliminating column bake out Preserve column performance for extended

period of time

ChromatoProbe Added Versatility for Superior Analysis of Solids, Liquids, and Slurries

Compounds such as street drugs, industrial solids, synthetic organic products, and plant tissues that normally are not considered amenable to GC/MS analysis can be easily investigated with the ChromatoProbe.

Samples are introduced into the PTV injector via disposable micro-vials. Non-volatile or thermally degraded components from the sample remain in the micro-vial allowing the system to remain clean.

ChromatoProbe Benefits: Increase uptime Minimize system contamination with

disposable micro-vials Directly desorb samples in the PTV injector

without added hardware (unique Direct Sampling Capability)

Additions to Enhance System Capability and Performance

Gas Chromatographs An Infusion of Innovation with a Legacy of Reliability

The GC is essential to the reliability, robustness, and sensitivity of any GC-MS analysis. Bruker’s philosophy of innovation is highlighted by the introduction of two new GC’s to support the ultra- sensitive SCION SQ. The compact 436 GC and the versatile 451 GC are now available with new back- flush technology and the innovative ChromatoProbe.

436 Gas ChromatographCompact design for those focused on routine applications requiring maximum sample throughput utilizing Split/Split-less or PTV/BF injection.

451 Gas ChromatographThe 451 GC provides maximum versatility for your SCION TQ GC-MS/MS system. Additional inlets and GC detectors make the 451 GC a must-have for labs seeking maximum versatility in their applications and detectors.

QUMA HSS40 Headspace Auto Sampler Perfect for analyzing VOC’s in solid or liquid samples 40/125 sample capacity – Crimp cap or screw cap 10 or 20mL vials 12 position oven for increased throughput 200°C sample heating for extended range Injection with 1 mL sample loop, optimized designed for EPC GC’s

MHE mode via single puncture ensure no leaks

Atomx Purge and Trap (P&T) System from Teledyne Tekmar Automated VOC Sample Prep System Combine an autosampler and purge and trap concentrator into a single platform Unique Automated Methanol Extraction (ME) features for high level soil samples 80-position carousel design for optimal throughput TekLink™ software with fully optimized user interface including diagnostic tools and

benchmark tests for instrument validation

Page 7: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

The perfect addition for the SCION TQ PTV inlet is the back flush option. Complex sample matrix can quickly ruin the chromatographic performance of your GC column. However, the PTV with Bruker’s “backflush” technique can reliably divert the higher boiling sample matrix away from the column. The benefits of this accessory are many: Run more samples per day - decrease analysis

times as the heavy components are quickly eliminated

Save time by eliminating column bake out Preserve column performance for extended

period of time

ChromatoProbe Added Versatility for Superior Analysis of Solids, Liquids, and Slurries

Compounds such as street drugs, industrial solids, synthetic organic products, and plant tissues that normally are not considered amenable to GC/MS analysis can be easily investigated with the ChromatoProbe.

Samples are introduced into the PTV injector via disposable micro-vials. Non-volatile or thermally degraded components from the sample remain in the micro-vial allowing the system to remain clean.

ChromatoProbe Benefits: Increase uptime Minimize system contamination with

disposable micro-vials Directly desorb samples in the PTV injector

without added hardware (unique Direct Sampling Capability)

Additions to Enhance System Capability and Performance

Gas Chromatographs An Infusion of Innovation with a Legacy of Reliability

The GC is essential to the reliability, robustness, and sensitivity of any GC-MS analysis. Bruker’s philosophy of innovation is highlighted by the introduction of two new GC’s to support the ultra- sensitive SCION SQ. The compact 436 GC and the versatile 451 GC are now available with new back- flush technology and the innovative ChromatoProbe.

436 Gas ChromatographCompact design for those focused on routine applications requiring maximum sample throughput utilizing Split/Split-less or PTV/BF injection.

451 Gas ChromatographThe 451 GC provides maximum versatility for your SCION TQ GC-MS/MS system. Additional inlets and GC detectors make the 451 GC a must-have for labs seeking maximum versatility in their applications and detectors.

QUMA HSS40 Headspace Auto Sampler Perfect for analyzing VOC’s in solid or liquid samples 40/125 sample capacity – Crimp cap or screw cap 10 or 20mL vials 12 position oven for increased throughput 200°C sample heating for extended range Injection with 1 mL sample loop, optimized designed for EPC GC’s

MHE mode via single puncture ensure no leaks

Atomx Purge and Trap (P&T) System from Teledyne Tekmar Automated VOC Sample Prep System Combine an autosampler and purge and trap concentrator into a single platform Unique Automated Methanol Extraction (ME) features for high level soil samples 80-position carousel design for optimal throughput TekLink™ software with fully optimized user interface including diagnostic tools and

benchmark tests for instrument validation

Page 8: SCION SQ GC-MS - easyfairs.com · GAS CHROMATOGRAPHY Innovation with Integrity The Gas Chromatographers’ Detector SCION SQ GC-MS Bruker Daltonik GmbH Bremen · Germany Phone +49

GAS CHROMATOGRAPHYInnovation with Integrity

The Gas Chromatographers’ Detector

SCION SQ GC-MS

Bruker Daltonik GmbH

Bremen · GermanyPhone +49 (0)421-2205-0 Fax +49 (0)421-2205-103 [email protected]

Bruker Daltonics Inc.

Billerica, MA · USA Fremont, CA · USAPhone +1 (978) 663-3660 Phone +1 (510) 683-4300 Fax +1 (978) 667-5993 Fax +1 (510) 490-6586 [email protected] [email protected]