+ All Categories
Home > Documents > Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D...

Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D...

Date post: 22-Dec-2015
Category:
Upload: emil-george
View: 225 times
Download: 4 times
Share this document with a friend
Popular Tags:
34
Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E
Transcript
Page 1: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Seat Cushion Testing Methods

Fire Test FAA Hand Book RegulationLab A Lab FLab B Lab GLab CLab DLab E

Page 2: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

All labs participating are using Park Oil Burner Model D. P. L.

Page 3: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Modification to Burner

Lab A -Tabs, Anemometer @ Airflow inletLab B - Tabs, Flow MeterLab C - Adjustable Air InletLab D - Tabs, Static DiskLab E - Tabs, AnemometerLab F - Tabs, Fuel Filter & Flow meter

Lab G - Static Disk

Page 4: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Method of Rotating Burner

Lab A - Mechanical Lab B - MechanicalLab C - Electrical Motor ActuatorLab D - MechanicalLab E - MechanicalLab F - ManualLab G - Electrical Motor Actuator

Page 5: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Method of Placing Temperature Measuring Instruments in Flame

Manual Mechanical Lab A Lab BLab F Lab C

Lab DLab ELab G

Page 6: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Fuel

Lab A - No. 2 Grade Diesel Fuel OilLab B - ASTM D2 Number 2 Lab C - Jet A FuelLab D - No. 2 Home Heating OilLab E - JP8Lab F - No. 2 DieselLab G - Jet A Fuel

Page 7: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Method for Measuring Fuel Flow

Lab A - Nozzle & Fuel PressureLab B - Flow MeterLab C - Graduated Cylinder and

StopwatchLab D - Collection MethodLab E - Graduated Cylinder Lab F - Flow MeterLab G - Timed Collection Method

Page 8: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Intermittent Replacement of Nozzle

Lab A - YesLab B - No Lab C - YesLab D - NoLab E - Yes, not oftenLab F - YesLab G - Yes

Page 9: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Distance of the stabilizer from end of the draft tube

Lab A - 4”Lab B - 4.9” Lab C - 2.72”Lab D - 4”Lab E - 3 13/16”Lab F - 4”Lab G - 3 ½”

Page 10: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Distance of the stabilizer from end of the draft tube

Lab A - 10.16cmLab B - 12.5cmLab C - 6.91cmLab D - 10.16cmLab E - 8.10cmLab F - 10.16cmLab G - 8.89cm

Page 11: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

NozzleLab A - Monarch 2.0 80 CCLab B - Monarch 2.25 80 AR Lab C - Monarch 2.25 80 ARLab D - Monarch 80 CCLab E - Monarch 80 CCLab F - Hago 80 2.25Lab G - Monarch 2.25 80 R

Page 12: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Orientation of Igniters

Lab A - 10:00 & 11:00Lab B - 6:00 Lab C - 10:00Lab D - 6:30Lab E - 10:00 & 7:00 Lab F - 12:00Lab G - 9:00 & 6:00

Page 13: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Dimensions of TabsLab A - 2.5” X .75”Lab B - 1.5” x .5” Lab C & G - N/ALab D - 1” X 1”Lab E - 1/16 thick 1 6/16” X ¾” X ¾”

Lab F - 2 thin steel Trapezoid, 2" long, measuring 2.25" at outer end; 1.5" at inner end and 2 rectangles 2" long X 1" wide

Page 14: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Dimensions of TabsLab A - 63.5mm X .19.05mmLab B – 38.1mm x 12.7mm Lab C & G - N/ALab D – 25.4mm X 25.4mmLab E – 1.59mm thick 34.93mm X

19.05mm X 19.05mm Lab F - 2 thin steel Trapezoid,

50.8mm long, measuring 2.25" at outer end; 38.1mm at inner end and 2 rectangles 0.8mm" long X 5.4mm wide

Page 15: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Static DiskLab A - N/ALab B - N/A Lab C - N/ALab D - Located 3.5” (8.89 cm)

Behind StabilizerLab E - N/ALab F - N/ALab G - Located directly behind

Stabilizer

Page 16: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Heat Flux Gauge

Lab A - Medtherm - H-201Lab B - Vatell - 1000-1ALab C - Hycal - C-1300-A-15-072-X2

Vatell - 1000-1 / S1K Amplifier Medtherm - 64-15-20K

Lab D - Vatell - 1000-1ALab E - Vatell -Lab F - Vatell - 1000-1Lab G - Medtherm - 64-20-20

Page 17: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Heat Flux Gauge Date of Last Calibration

Lab A - 7/11/2003Lab B - 10/8/2002Lab C - Annually or sooner if necessaryLab D -12/4/2003Lab E - 6 months ago Lab F -12/3/2001Lab G -3/7/2003 Annually or sooner if necessary

Page 18: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

In Cool Weather Is Heat Flux Cooled With Warm Water to Avoid

Condensation on the Surface During Cold Weather?

• Lab A - No Ambient Temp. 70° FLab B - NoLab C - Yes, Maintained @ 68° FLab D - NoLab E - No Lab F - NoLab G - No

Page 19: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Thermocouple

Lab A - Type K 1/16" gageLab B - Left Blank Lab C - Type K 1/16" gageLab D - Type K-inc.-G-T4-12.00”Lab E - Type K 1/16" gageLab F - Type K 1/16" gageLab G - Type K 1/16" gage

Page 20: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Thermocouple Flame Time

Lab A - 5 HoursLab B - 1-3 minutes per calibration Lab C - Variable - Replaced PeriodicallyLab D - No time keptLab E - 45 Seconds Lab F - Less than 30 HoursLab G - 3 Hours, 22 min.

Page 21: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Fuel Pressure Gauge

Lab A - 100 PSILab B - Not reportedLab C - 85 PSILab D - 93 PSILab E - 100-105 PSILab F - 85 PSILab G - 85 PSI

Page 22: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Last Calibration of Fuel Gauge

Lab A - 1/30/2004Lab B - 1/2004Lab C - 1995Lab D - 2 years agoLab E - UnknownLab F - 5/16/2002Lab G - Replaced Annually

Page 23: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Wires Used to Secure Fabric Test Specimen

Lab A - 1 on BackLab B - 1 on Back Lab C - None – Binder Clips Lab D - 1 on BackLab E - 1 on BackLab F - 1 on BackLab G - 1 on Back

Page 24: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Wires Used to Secure Leather Test Specimen

Lab A - 1 on Back 2 on BottomLab B - 3 on Back & 3 on BottomLab C - No Reply Lab D - 1 on Back 2 on BottomLab E - Not reportedLab F - 2 on BackLab G - 3 on Back & 3 on Bottom

Page 25: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Is Chair Frame Affixed to Scale?

Lab A - YesLab B - Yes Lab C - Yes Lab D - YesLab E - YesLab F - NoLab G - Yes

Page 26: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Method of Weighing Posttest

Lab A - Continuous Reader Manual CalculateLab B - Continuous Reader Manual Calculate Lab C - Continuous Reader Manual CalculateLab D - Continuous Reader Manual Calculate Lab E - Continuous Reader Manual Calculate Lab F - Remove Cushions and place on

scaleLab G - Computer displays & calculates wt./%

wt. Loss continuously

Page 27: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Air Velocity Transducer

Lab A - Extech Ins. Model 44104 Date Cal. 1/12/2004Lab B - Omega Model HH30A Date Cal. 1/20/2003Lab C - Kurz Model 441S Date Cal. 1/27/2004Lab D - Dwyer Ins. Model 641-6 Date Cal 11/20/2003Lab E - Omega Model HH30A Date Cal. NewLab F - Airflow Ins. Model TA400 Date Cal. 6/5/2002Lab G - Omega Model HHF618 Date Cal. 12/9/2003

Page 28: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Variance in Pre-post Test Calibration

Lab A - NoLab B - No Lab C - Seldom Lab D - NoLab E - Generally post test is close to

per-testLab F - Not ObservedLab G - Yes, Heat Flux is cooler &

Thermocouples are warmer still in spec

Page 29: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Dimensions of Burn Chamber

Lab A - 10’ X 9’ X 8’Lab B - 18’ x 11.5’ x 13.1’ Lab C - 25’ X 13’ X 14’Lab D - 16’ X 13’ X 14’Lab E - Left BlankLab F - 12’ X 10’ X 8’Lab G - 12’ X 12’ X 8’ –10’ Shed roof

Page 30: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Dimensions of Burn Chamber

Lab A - 3.m X 2.74m X 2.44mLab B - 5.5m x 3.5m x 4m Lab C - 7.62m X 4m X 4.27mLab D - 4.88m X 4m X 4.27mLab E - Left BlankLab F - 3.66m X 3.m X 2.44mLab G - 3.66m X 3.66m X 2.44m –3.m

Shed roof

Page 31: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

How Is Air Replenished to Burn Chamber

Lab A - High Temperature VentilatorLab B - Left Blank Lab C - Rooftop Plenum for minimal cell

VentilationLab D - Outside air through wall ventsLab E - No forced air into room Lab F - 7’ X 3’ door with access holes in

walls for instrumentationLab G - Adjustable vents every two foot at

base & top of walls

Page 32: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Is the Anemometer Permanently Installed?

Lab A - Yes Calibration Date 1/12/2004Lab B - No Calibration Date 1/20/2003Lab C - No Calibration Date 1/27/2004Lab D - Yes Calibration Date 8/20/2003Lab E - Yes Calibration Date NewLab F & G - FAR Test Method N/A

Page 33: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Scales

Lab A - Weighmaster Model 1300Lab B - Busch 332 Lab C - Toledo Scale 2095Lab D - Rice Lake 1040Lab E - Not ReportedLab F - Penn Scale Model 17300Lab G - Advanced Weight Tech. BM 2424-

100 & IQ+510-2A

Page 34: Seat Cushion Testing Methods Fire Test FAA Hand Book Regulation Lab A Lab F Lab B Lab G Lab C Lab D Lab E.

Scale Calibration

Lab A - 7/7/2003

Lab B - 3/16/2003

Lab C - 1/30/2004

Lab D - 1/9/2004

Lab E - Has Not Been Calibrated by Mfg.

Lab F - 6/2/2002

Lab G - 5/6/2003


Recommended