Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPHS
PHOTOGRAPH #1BUILDING 23
SECTION E
Contractor has cleaned construction debris and raked grounds.
PHOTOGRAPH #2 BUILDING 23 SECTION C
Contactor in process of removing construction debris and raking grounds.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 2
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #3BUILDING 23
UNIT # 2317
Gap at head of both windows in guest bedroom exceed allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
PHOTOGRAPH #4 BUILDING 23 UNIT #2317
Gap at jambs of windows spacing is at maximum spacing tolerance for manufacturer's NOAs for integral fin anchorage.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 3
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #5BUILDING 23
UNIT #2318
Gap at head of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
PHOTOGRAPH #6 BUILDING 23 UNIT #2318
Gap at jamb of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 4
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #7 BUILDING 23 UNIT #2325
Gap at head of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
PHOTOGRAPH #8 BUILDING 23 UNIT #2325
Gap at jamb of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 5
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #9 BUILDING 23 UNIT #2325
Dupont flashing overlaps as per manufacturer's requirements at jambs to sill transition.
PHOTOGRAPH #10 BUILDING 21 SECTION H
Stucco sub-contractor bas applied brown coat of stucco and begun finish coat of stucco.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 6
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #11 BUILDING 21
SECTION G
Stucco sub-contractor bas applied scratch coat of stucco.
PHOTOGRAPH #12 BUILDING 21 SECTION G
Sub-contractor has applied brown coat of stucco and begun finish coat of stucco.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 7
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #13 BUILDING 21 SECTION F
Metal lathing and stucco accessories have been installed and inspected for fastening and overlapping requirements.
PHOTOGRAPH #14 BUILDING 21 SECTION F Metal lathing and stucco accessories have been installed and inspected for fastening and overlapping requirements.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 8
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #15 BUILDING 21 SECTION F
Metal lathing and stucco accessories have been installed and inspected for fastening and overlapping requirements.
PHOTOGRAPH #16 BUILDING 21 SECTION F
New vented soffit has been installed and inspected.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 9
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #17 BUILDING 21 UNIT #2116
Gap at head of one window in living room exceeds allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
PHOTOGRAPH #18 BUILDING 21 UNIT #2116
Gap at jambs of windows within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 10
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #19 BUILDING 21 UNIT # 2128
Gap at windows within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
PHOTOGRAPH #20 BUILDING 21 UNIT # 2111
Gap at windows within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 11
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #21 BUILDING 21 SECTION E
Contractor removing old paints and rust at breezeway railings with electric grinders.
PHOTOGRAPH #22 BUILDING 21 SECTION D
Contractor performing framing and gable end repairs.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 12
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #23 BUILDING 21 SECTION B
Damaged wall framing inspected and marked for repairs.
PHOTOGRAPH #24 BUILDING 21 SECTION A
Damaged breezeway framing inspected and marked for repairs.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 13
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #25 BUILDING 21 SECTION A
Damaged breezeway framing inspected and marked for repairs.
PHOTOGRAPH #26 BUILDING 21 SECTION A
Damaged balcony deck board have been identified and marked for repairs.
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 14
© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20
PHOTOGRAPH #27 BUILDING 21 SECTION A
Framing and balcony damage has been identified and marked for repairs.