SECTION D COMPRESSOR NOMENCLATURE TOPICS Welded Compressors .................................................. D2 HFC Welded Compressors.......................................... D4 A-Line .......................................................................... D6 CRKQ, CIKQ ............................................................... D8 CR7, CR6, CRKF, CS, CF ......................................... D10 Copelametic ® ............................................................. D12 Copeland Discus ..................................................... D14 Refrigeration Copeland Scroll ® .................................. D16 A/C Copeland Scroll ® ................................................. D18 Condensing Unit (All models except M-Line) ............ D20 M-Line Condensing Unit ............................................ D22 This section contains current information on Copeland ® products. Information on obsolete models can be obtained from your local Emerson Climate Technologies wholesaler. For individual model designations, visit On-Line Product Information at www.emersonclimate.com.
Transcript

SECTION D

COMPRESSOR NOMENCLATURE

TOPICSWelded Compressors .................................................. D2HFC Welded Compressors .......................................... D4A-Line .......................................................................... D6CRKQ, CIKQ ............................................................... D8CR7, CR6, CRKF, CS, CF ......................................... D10Copelametic® ............................................................. D12Copeland Discus™ ..................................................... D14Refrigeration Copeland Scroll® .................................. D16A/C Copeland Scroll® ................................................. D18Condensing Unit (All models except M-Line) ............ D20M-Line Condensing Unit ............................................ D22

This section contains current information on Copeland® products. Information on obsolete models can be obtained from your local Emerson Climate Technologies wholesaler.

For individual model designations, visit On-Line Product Information at www.emersonclimate.com.

D2

NOMENCLATURE • WELDED COMPRESSORS

Code Description

EFRTS

= High Effi ciency= Low Temperature= High Temperature= Two Speed= Medium Temperature

CompressorFamily SeriesEither a number or a letter established for each product model.

DisplacementA letter only, arbitrarily assigned for each different displacement within any one family series.

Comp. Motor Rating

Nominal (HP)

Code

¼1/3½½¾11

1-1/41-1/21-3/4

22-1/42-3/4

33-1/2

44-1/2

57-1/2

91012

0025003300500051007501000100012501500175020002250275027503500400045005007500090010001200

X X X X - X X X X

Model VariationA number only, assigned to indicate different model types within any one family series.

D3

NOMENCLATURE • WELDED COMPRESSORS

Compressor Motor Types

Phase Description Code

1 Capacitor Run - Capacitor Start C

1 Induction Run - Capacitor Start I

1 Capacitor Run - Permanent Split Capacitor

P

3 Three Phase T

Compressor Motor Protection

Type Protection Code

External Inherent Protection-One Protector (Line Break)Use with Contactor

A

Internal Thermal Protection – Electronic Sensors; andControl Module ExternalUse with Contactor

S

Internal Inherent Protection – One Protector (Line Break) F

Electrical Codes

60 HZ 50HZ Code

115-1230-1208/230-3460-3575-3265-1208/230-1200/230-3

-200/240-1200/220-3380/420-3500-3220/240-1380/420-3200-1220/240-1200/240-3

ABCDEJMVZ5

(Refer to model data or nameplate for specifi c nominal voltage.)

Product VariationsNumbers will be assigned asfollows:1. Number – 100 is standard compressor used in

Copeland brand Condensing units.2. Number – 200 indicates a STANDARD Com-

pressor and Component Parts B/M and Model No.

3. Number – 700 and –900 series indicate OEM and Wholesaler service B/M and model number.

4. Number – 201 and larger will be assigned for all other variations of a given model.

- X X X - X X X

D4

NOMENCLATURE • HFC WELDED COMPRESSORS

Oil Identifi er“E” designates Polyol Ester. No digit if Mineral Oil

X X X X X X X

Model VariationA number or letter, assigned to indicate different model types within any one family series.

Compressor nominal capacity at rating conditions to two signifi cant digits.

Capacity MultiplierC = 100K = 1000

Compressor Family SeriesEither a number or a letter established for each product model.

Code Description

R

SFTV

=High or Medium Temperature, Air Conditioning and Heat Pump=Medium Temperature=Low Temperature=Two Speed=Variable Speed

D5

NOMENCLATURE • HFC WELDED COMPRESSORS

- X X X - X X X

Bill of Material Product Variations

Compressor Motor Types

Phase Description Code

1113

Capacitor Run – Capacitor Start Induction Run – Capacitor Start

Capacitor Run – PermanentCapacitor Run – Split Capacitor

CIPT

Typical Electrical Codes

60 HZ 50HZ Codes

115-1230-1

208/230-3460-3575-3265-1

- -

208/230-1 -

200/230-3

-200/240-1200/230

380/420-3550-3

220/240-1220/240-3380/420-3

200-1220/240-1200/240-3

ABCDEJRMVZ5

(Refer to model data or nameplate for specifi c nominal voltage.)

Compressor Motor Protection

Type Code

External Inherent Protection-One Protector (Line Break)

Use with Contactor

A

Internal Inherent Protection-One Protector (Line Break)

Use with Contactor

F

D6

NOMENCLATURE • A-LINE COMPRESSORS

Compressor Shell Series

A S E 2 4 C 3 E

Oil Identifi er“E” designates Polyol Ester.

Model Series VariationA number or letter arbitrarily assigned to indicate different model types within any one family series.

Capacity MultiplierC: 100

K: 1,000

CapacityCompressor nominal capacity at 60 Hertz rating condition to two signifi cant digits.

Compressor Family Series

Application Range

Code Description Rating Point

S

FR

Medium & ExtendedTemperature R-404A, R-22Extended Medium R-134a, R-404AHigh Temperature R-134a

20/120

-10/12045/130

D7

NOMENCLATURE • A-LINE COMPRESSORS

- I A A – 2 0 1

Product VariationsThree-digit Bill of Mate-rial number that indicates compressor confi guration and may include accessories.

Compressor Motor Protection

Type Protection Code

Internal Thermal Protection – Electronic Sensors; and ControlModule External

S

Internal Inherent Protection – One Protector (Line Break)Use with Contactor

F

External Inherent Protection – One Protector (Line Break)Use with Contactor

A

BTU Model Families

A R CRK6 CRKQ CS

22134a404A507

XX

XXX

X X XXXX

Voltage Ranges (Typical)

Voltage 60 Hertz Rating 50 Hertz Rating

Family Code Rating Min. Max. Rating Min. Max.

C, RAAllAllAllAllC, RAC, RAAllC

AACDEJVVZZ5T

115-1115-1208/230-3460-3575-3265-1208/230-1208/230-1--200/230-3-

103103207414518239197187

--

187-

127127253506633292253244

--

253-

-100200/220-3380/420-3500-3220/240-1200-1200-1220/240-1220-240-1200-240-3200/240-1

-90180342450198180180198198180180

-110240462550264200220264254264252

Compressor Motor Types

Phase Description Code

111

31

Capacitor Run – Capacitor StartInduction Run – Capacitor StartCapacitor Run – Permanent Split CapacitorThree PhaseInduction Run – Split Phase

CIP

TS

D8

NOMENCLATURE • CRKQ, CIKQ MODELS

X X X X X X E

Indicates compressors with polyol ester oil.

CapacityCompressor nominal 60 Hertz capacity at ARI rating condition to two signifi cant digits.

Compressor Family SeriesLetter “C” established for this family of compressors.

Model Series VariationLetter “Q” assigned to indi-cate “Quiet Compressors.”

Application RangeCode Description R High and medium temp.

Capacity MultiplierK = 1000

D9

NOMENCLATURE • CRKQ, CIKQ MODELS

- X X X - X X X X X

Product VariationsThree-digit Bill of Mate-rial number that indicates compressor confi guration and accessories included.

Compressor Motor Types

Phase Description Code

1

3

Capacitor Run – Permanent Spilt CapacitorThree PhaseGeneral-3 Lead Single Voltage6 Lead Part Winding

P

T

External VariationsOptional alpha letters that indicate external ac-cessories.

Typical Electrical Codes

50 HZ 60 HZ Code

200-1200/240-1220/240-1380/420-3200/240-3

208/230-1--460-3200/230-3

VTZD5

Compressor Motor Protection

Type Protection Code

Internal inherent protection – One protector, Use with contactor(single or three phase)

F

D10

NOMENCLATURE • CR7, CR6, CRKF, CS, CF MODELS

X X X X X X E

Capacity MultiplierK = 1000

Model VariationA number or letter, assigned to indicate different model types within any one family series.

Indicates compressors with polyol ester oil.

Compressor nominal capac-ity at rating conditions to two signifi cant digits.

Compressor Family SeriesEither a number or a letter established for each product model.

Application Range

Code Refrig. Description

I, R R-22High Temp.A/C & Heat Pump

S R-404A/R-22/R-134a/R-507

Med. Temp.Refrigeration

FR-404A/R-507 Low Temp.

Refrigeration

P R-410A High Temp.High Pressure

D11

NOMENCLATURE • CR7, CR6, CRKF, CS, CF MODELS

- X X X - X X X

Product VariationsNumbers will be assigned as follows:1. Number –105 indicates a standard B/M with

molded plug connection and a straight discharge and suction fi tting.

2. Number –130 indicates standard B/M with molded plug.

3. Number –230 indicates a standard compressor B/M and model number.

4. Number –270 indicates a standard compressor B/M with crankcase heater.

5. Number –500 series indicates international standard compressor B/M and model number.

6. Number –730 indicates a standard OEM service B/M and model number.

7. Number –700 and –900 series indicate standard OEM and Wholesaler service B/M and model number.

8. Number –830 indicates a standard OEM service B/M with a molded plug.

Compressor Motor Types

Phase Description Code

1 Capacitor Run – Permanent Split Capacitor P

3

Three PhaseGeneral – 3 Lead Single Voltage 6 Lead Part Winding (575 Volt)

T

Electrical Codes

60 Hz. 50 Hz. Code

208/230-3460-3575-3265-1-208/230-1---200/230-3

200/220-3380/420-3500-3220/240-1380/420-3200/220-1220/240-1360/460-3180/260-1200/240-3

CDEJMVZ1*2*5

* Wide voltage range for India produced products

Compressor Motor Protection

Type Protection Code

Internal Inherent Protection – One Protector (Single or three phase)

F

D12

NOMENCLATURE • COPELAMETIC MODELS

K A T A – 0 1 0 0

Refrigerant-Cooled Code Description R = Std. Refrig. Cooled

Water-Cooled Code Description W = Std. Water Cooled

Air-Cooled Code Description A = Std. Air Cooled

Model VariationA number assigned to indi-cate major variations within any one family series.

Displacement and Valve PlateA letter only, assigned for each different displacement valve plate combination within any one family series.

Compressor Family SeriesEither a number or a letter established for each product model.

Comp. Motor Rating

Nominal (HP) Code

1/3½½¾1

1-1/222333452025303540

003300500051007501000150020002100300031003110400050020002500300035004000

D13

NOMENCLATURE • COPELAMETIC MODELS

- C A V - 2 0 1

Product VariationsNumbers will be assigned as follows:1. Number –100 is standard compressor used in

Copeland brand Condensing Units.2. Number –200 indicates a STANDARD Compressor

Parts B/M and Model No.3. Number –201 and larger will be assigned for all

other variations of a given model.4. Number –800 indicates a standard replacement

Compressor and Component Parts B/M and Model No. –240 volt control.

5. Number –801 indicates a standard replacement Compressor and Component Parts B/M and Model No. –120 volt control.

Compressor Motor Types

Phase Description Code

1 Capacitor Run – Capacitor Start C

1 Induction Run – Capacitor Start I

3 Three Phase T

3 Wye (star) Delta E

3 6 Lead Part Winding or Across The Line – except 575V

F

Compressor Motor Protection

Type Protection Code

External Inherent Protection-One Protector, (Line Break)Use with Contactor

A

Internal Inherent Protection-One Protector (Line Break)Use with Contactor

F

Internal Thermal Protectors-Electronic Sensors; and ControlModule ExternalUse with Contactor

S

Electrical Codes

60 Hz. 50 Hz. Code

115-1230-1208/230-3460-3575-3208/230/460-3--230/460-3200-3208/230-1-200/220/380-3

--200/220-3380/420-3550-3200/380/400-3210/240/380/420-3380/420-3200/400-3-200/220-1220/240-1200/380-3

ABCDEKLMNUVZ8

D14

NOMENCLATURE • COPELAND DISCUS MODELS

X X X X X X X X X

Tandem Style ModelsIndicated by the digit representing the comp. model series connectedin tandem with a comp. of the model series indicated by the fi rst digit.

Compressor Cooling

Code Description

A D R T W

Air cooled DiscusRefrigerant cooledStd. two stageWater cooled

Model VariationEither a number or a letter assigned to indicate major variations within any one family series.

Displacement and Valve PlateA letter only, arbitrarily assigned for each different displacement valve plate combination within any one family series

Compressor Family SeriesEither a number of a letter extablished for each product family.

May also be “0” (Mineral Oil) “E” (POE Oil) “L” (Less Oil)

Capacity MultiplierK - 1,000

M - 10,000

Nominal Capacity at Rating Condition 2 numeric characters

Primary Application RangeR = ARI High Temp, Rated @ 45/130S = ARI Med Temp, Rated @ 20/120F = ARI Low Temp, Rated @ -25/105

D15

NOMENCLATURE • COPELAND DISCUS MODELS

- X X X X X X

Product VariationsNumbers will be assigned as follows:1. Numbers -001 through -199 are reserved for

sub-b/m numbers.2. Numbers -200 indicates a standard compressor

and component parts b/m and model no.3. Numbers -201 and larger will be assigned for all

other variations of a given model.

Compressor Motor Protection

Type Protection Code

External inherent protection-one protector (line break) use with contactor

Internal inherent protection-one protector use with contactor

Internal thermostat(s); and ext. supplementary protector(s) use with contactor

Internal thermostat(s); and three ext. supplementary protectors use with contactor

Internal thermal protectors-electronic sensors; and control module external. Use with contactor.

Internal thermal protectors-elec-tronic sensors; and control mod-ule external. Use with contactor (For European use only)

A

F

H

L

S

W

Electrical Codes

60 Hz. * 50 Hz. (Typical) Code

115-1230-1208-230-3 460-3575-3 - - - -208-1 - -208/230/460-3 - - - -230/460-3 - - - - - - - -200-3208-230-1 - -Misc. A.C. Ratings - - - -200-1100-1200-230-3230-3380200/220/380

100-1 200-1 200/220-3 380/400-3 500-3 115-1 230-1 200-1 208/230-1 200/400-3 210/240/380-3 380/420-3 200/400-3 200/380-3 200/240-3 220-1 200-1 - - 200-1 200/220-3 X 500-3 220/240-1 200-1 100-1 - - - - 346 200/346

ABC DEFGHIKLMNPRSTUVW YZ345678

Compressor Motor Types

Single Phase Motors Code

Capacitor run - capacitor startInduction run - capacitor startInduction run - split phaseInduction run - capacitor start, low torque

CISX

Three Phase Motors Code

General 3 Lead single voltage 6 Lead part winding (575 volt) 9 Lead dual voltageStar (wye) delta6 Lead motors Part winding or across the line

T

E

F

D16

NOMENCLATURE • REFRIGERATION SCROLL MODELS

X X X X X X X X X

Compressor Family SeriesEither a number or a letter established for each product model.

Z = Scroll

Capacity Multiplier M: 10,000 K: 1,000 C: SCFM

Type of OilG = PAGE = POE

“blank” = Mineral OilCompressor nominal capac-ity at rating conditions to two signifi cant digits

Model VariationA number or letter, assigned to indicate different model types within any one family series.

Application Range

Code Description

B

SF

CMNXH

High/Medium TemperatureMedium Temp.Low Temp. with Injection portHeliumMarinizedGas BoosterAsia Condensing UnitHeat Pump

Optional Modulation

Code Description

DHHV

DigitalHorizontalHorizontal Variable Speed

D17

NOMENCLATURE • REFRIGERATION SCROLL MODELS

- X X X - X X X

Product VariationsNumbers will be assigned as follows:1. 230/231 - Standard Compressor & Component

Parts w/ Flag Terminal 2. 250/251 - Standard Compressor & Component

Parts w/ Screw Terminal 3. 240/241 - Rotalock Compressor & Component

Parts w/ Flag Terminal 4. 261/265 - Rotalock Compressor & Component

Parts w/ Screw Terminal 5. 900 series indicates standard OEM and

wholesaler service.6. Other numbers designate variations.

Compressor Motor Types

Phase Description Code

1 Capacitor Run – Permanent Split Capacitor

P

3 General3 Lead Single Voltage6 Lead Part Winding (575 Volt)

T

Voltage Ranges (Typical)

Voltage 60 Hertz Rating 50 Hertz Rating

Code Rating Min. Max. Rating Min. Max.

CDEV57JR

208/230-3460-3575-3208/230-1200/230-3380-3265-1-

187414518197180342239-

253506633253253418292-

200-3380/420-3500-3200-1200/220-3-220/240-1220/240-3

180342450180180-198180

220462550220242-264264

Compressor Motor Protection

Type Protection Code

Internal Inherent Protection-

One Protector Use with Contactor(Single or Three Phase)

F

External Electronic Protection

(Three Phase)

W

D18

NOMENCLATURE • A/C SCROLL MODELS

X X X X X X X X X

Compressor Family SeriesEither a number or a letter established for each product model.

Capacity MultiplierK: 1,000

M: 10,000

Type of OilE – 3MA POE OilCompressor nominal capacity at

rating conditions 2 – 3 numeric characters.

ModulationD – DigitalDU – Digital Uneven TandemDT – Digital Even TandemH – HorizontalI – HeatingJ – Digital HeatingS – UltraTechT – Even TandemU – Uneven TandemV – Velocity Variable

Model VariationA number or a letter, assigned to indicate different model types within any one family series.

Application Range

Code Refrig. Description

P R-410A High TemperatureUltra High Pressure

R R-22/407C/134a High Temperature

D19

NOMENCLATURE • A/C SCROLL MODELS

- X X X - X X X

Product Variations1. 130/135/160 - Molded Plug2. 230/235/260 - Quick Terminals T-box3. 250/265 - Screw Terminals T-box4. 7xx/9xx - T-box Service5. 8xx - Molded Plug Service

Compressor Motor Types

Phase Description Code

1 Capacitor Run – Permanent Split Capacitor

P

3 General3 Lead Single Voltage6 Lead Part Winding (575 Volt)

T

Electrical Codes

60 Hz. 50 Hz. Code

208/230-3460-3575-3265-1--208/230-1Misc.200/230-3380-3

200-3380/420-3-220/240-1380-420-3220/240-3-Misc.200/220-3-220/240-1

CDEJMRVX57Z

Compressor Motor Protection

Type Protection Code

Internal Inherent Protection-One Protector Use with Contactor(Single or Three Phase)

F

External Electronic Protection-Kriwan Module(Three Phase)

W

D20

NOMENCLATURE • CONDENSING UNIT

X X X X - X X X X

Condensing Unit Family Series

Design Series and Refrigerant

Letters (Except K,L,M)K, LMNumbers (Except 6 & 7)6, 7X, 9

R-12R-22 LTR-22 LT DiscusR-22/R-502R-12/R-502Special Design

(Different series type may indicate a major design revision.

New HFC Refrigerant Indicator

Pressure Rating Approved Refrigerants

Standard Models

Special Designs

MediumHigh and MediumHigh

TPJ

RNE

Type of Design

Type Code

Air CooledNo condenserWater cooledEvaporating Pan BaseDiscus

ANWED

Typical Motor Rating

Nominal (HP) Code

1/41/31/23/41

1-1/22

2-1/23

3-1/2456

7-1/29101520222527304050607080

002500330050007501000150020002500300035004000500060007500900100015002000220025002700300040005000600070008000

*NOTE: Left hand position may contain a letter indicating a revision (on units less than 10 HP).Right hand position may contain the letter “Z” indicating a Gla-cier™ scroll compressor.

Application Temperature*

Temperature Range Code

High Temperature45ºF Max.; 0ºF Min. H

Medium Temperature25ºF Max.; -5ºF Min. M

Medium Temperature25ºF Max.; -25ºF Min. F

Low Temperature0ºF Max.; -40ºF Min. L

Extra Low Temperature-20ºF Max.; -40ºF Min. E

Two Stage0ºF Max.; -40ºF Min. T

Two Stage (Extra Low)-30ºF Max.; -80ºF Min. U

Commercial ApplicationHigh & Med. TemperatureSingle Refrigerant

C

Dual ApplicationR-22 HT, R-502 MT D

Multiple ApplicationR-12 H/MT, R-502 LT B

NOTE: Limited or extended range will be shown in performance data tables.

All Models Except M-Line

D21

NOMENCLATURE • CONDENSING UNIT

- X X X - X X X

Compressor Motor Type

Single Phase Motors Code

Capacitor Run-Capacitor StartInduction Run-Capacitor StartInduction Run-Split PhaseInduction Run-Capacitor Start, Low TorqueCapacitor Run-Permanent Split Capacitor

CISXP

Three Phase Motors Code

General 3 Lead Single Voltage 6 Lead Part Winding 575 V 9 Lead Dual VoltageStar (Wye) Delta6 Lead Motors Part Winding or Across the Line

T

EF

Bill of Material Product Variations

Variation (B/M) Number UL/CSA Eligibility

001 thru 099 Intended for UL Listing and CSA Certifi ed.

100 thru 299 Intended for UL Recogni-tion and CSA Certifi ed.

300 thru 399 Not Eligible for either UL Listing, LU Recognition, or CSA Certifi ed.

Compressor Motor Protection

Type Protection Code

External InherentProtection – One Protector,(Line Break)Use with Contactor(single or three phase)

A

Internal InherentProtection – One Protector, Usewith Contactor.(single or three phase)

F

Internal Thermostat(s);and External Supple-mentary Protector(s).(Two for 3Ø, one for 1Ø.)Use with Contactor.

H

Internal Thermostat(s);and Three External Supplementary Protectors. Use with Contactor.

L

Internal Thermal Protectors – Electronic Sensors; and Control Module External.Use with Contactor.

S

Internal Thermal Protectors – Electronic sensors; and control module external. Use with contactor. (For European use only).

W

Typical Electrical Codes

60 Hz. 50 Hz. Code

115-1230-1208/230-3460-3575-3--208-1-265-1208/230/460-3--230/460-3All D.C. Ratings----200-3208/230-1-Misc. A.C. Ratings--200-1100-1200/230-3230-3

100-1200-1200/220-3380/400-3500-3115-1230-1200-1208/230-1220/240-1200/400-3210/240/380-3380/420-3200/400-3

200/380-3200/240-3220-1200-1-200-1200/220-3

200/220-3220/240-1200-1100-1--

ABCDEFGHIJKLMNOPRSTUVWXYZ3456

*NOTE: When applicable, specifi c 50 Hz ratings (not necessarily identical to typical shown above) will be shown as alternate on 60 Hz rated models.

D22

NOMENCLATURE • M-LINE CONDENSING UNIT

M A A H -

CFC & HCFC Construction & Refrigerant Indicator(All Model Codes Signify UL Recognized Units)

R-12 R-22R-502 Receiver

Construction StylePower Cord

Fan Guard BX

AGIJKLUV

EMYDPQST

X

X

X

X

XXXX

XX

XX

XX

XX

Indicates M-Line Condensing Unit

Series

Base SizeA – 13” x 17” SteelB – 10” x 12” SteelE – 14-1/4” x 16” CopevapF – 12” x 17-1/2” SteelG – 10” x 21” SteelH – 6-1/2” x 15-1/2” SteelK – 15-1/2” x 18” SteelN – 10” x 12” CopevapP – 11” x 20” CopevapY – 10-1/4” x 14” Steel

Temperature ApplicationH High TemperatureM Medium TemperatureL Low Temperature

New HFC Refrigerant Indicator No reference to Construction and UL or CSA

Pressure Rating of Approved Refrigerants M-Line

MediumHigh and MediumHigh

234

D23

NOMENCLATURE • M-LINE CONDENSING UNIT

- 0 033 - IAA - XXX

Common Bill of Material Variations

CFC & HCFC Models

010100’s200’s

Wholesale (Single Pack)OEM (Single Pack)OEM (Multi Pack)

HFC Models

New HFC products have the same B.O.M. structure as F-Line.

Hot Gas Evaporator Tube

OEM

No TubeEpoxy Coated Copper TubeMonel Tube

Voltage (Start Torque)

IAASAAPAAIAVCAVIASIAZSAZ

115-1-60115-1-60115-1-60208/230-1-60208/230-1-60220-1-50220/240-1-50220/240-1-50

(High)(Low)(Low)(High)(High)(High)(High)(Low)

Nominal HP

M-Line HP

013017020 to 023024 to 027032 to 037049 to 051075100

1/81/61/51/41/31/23/41


Recommended