10
Westmoreland County Security Legend NTS MR SP-LEGEND SECURITY PLAN BD ACPe CRe De De DVRe ERe ESe KPe LAe Me NVRe RXe Te Xe VWSe REPLACE EXISTING ACCESS CONTROL WORKSTATION EXCEPT AT MANOR. REPLACE EXISTING ACCESS CONTROL PANEL(S) EXCEPT AT MANOR. DELETE EXISTING BADGE PRINTER. REUSE EXISTING CARD READER AT ALL FACILITIES EXCEPT AT THE JUVENILLE DETECTION CENTER. REUSE EXISTING CARD READER WITH KEYPAD AT ALL FACILITIES EXCEPT AT JUVENILLE DETENTION CENTER. REUSE EXISTING DOOR CONTACT. REUSE EXISTING DURESS ALARM BUTTON. REUSE EXISTING DELAYED EGRESS LOCK. REUSE EXISTING DOOR RELEASE BUTTON. DELETE EXISTING DIGITAL VIDEO RECORDER EXCEPT FOR SUPPORT OF CERTAIN EXISTING CAMERAS IN THE COURTHOUSE ANNEX. SEE ANNEX PLANS FOR CAMERA LOCATIONS. REUSE EXISTING ELECTRIC LOCKSET. REPLACE EXISTING EMERGENCY RELEASE STATION. REUSE EXISTING ELECTRIC STRIKE. REPLACE EXISTING INTERCOM STATION. EXISTING KEYPAD, SEE SHEET NOTES. REUSE EXISTING LOCAL ALARM SOUNDER. REUSE EXISTING ELECTROMAGNETIC LOCK. REPLACE EXISTING MONITOR UNLESS NOTED OTHERWISE. REPLACE EXISTING NETWORK VIDEO RECORDER. REUSE EXISTING REQUEST-TO-EXIT MOTION SENSOR. EXISTING TELEPHONE: SEE SHEET NOTES. REPLACE EXISTING VIDEO WORKSTATION REPLACE EXISTING EXIT PUSHBUTTON. REPLACE EXISTING FIXED CAMERA EXCEPT AT MANOR. EXISTING PAN,TILT, ZOOM CAMERA: SEE SHEET NOTES. REUSE EXISTING IP NETWORK CAMERA. EXISTING FIXED CAMERA TO REMAIN ON EXISTING VICON VIDEO SURVEILLANCE SYSTEM. EXISTING SECURITY DEVICES CKe DEe Ee V IP AWSe BPe ICe DRe MONe SHEET NAME LOCATION TITLE SP-LEGEND ALL BUILDINGS SECURITY LEGEND SP-DET-201 ALL BUILDINGS SYSTEM DIAGRAM SP-DET-202 PRISON PRISON SYSTEM DIAGRAM SP-DET-203 COURTHOUSE ANNEX PARK POLICE DESK SECURITY LAYOUT SP-DET-204 ALL BUILDINGS WHERE APPLICABLE ACCESS CONTROL PANEL RISER DIAGRAMS SP-DET-205 ALL BUILDINGS WHERE APPLICABLE SECURITY DEVICE DIAGRAMS SP-DET-206 ALL BUILDINGS WHERE APPLICABLE ACCESS CONTROL ROUGH-INS DRAWING #1 SP-DET-207 ALL BUILDINGS WHERE APPLICABLE ACCESS CONTROL ROUGH-INS DRAWING #2 SP-DET-208 ALL BUILDINGS WHERE APPLICABLE CAMERA ROUGH-INS DRAWING #1 SP-DET-209 ALL BUILDINGS WHERE APPLICABLE CAMERA ROUGH-INS DRAWING #2 SP-CH-101 COURTHOUSE EAST ELEVATION SP-CH-102 COURTHOUSE WEST ELEVATION SP-CH-103 COURTHOUSE BASEMENT SECURITY DEVICE PLAN SP-CH-104 COURTHOUSE FIRST FLOOR SECURITY DEVICE PLAN SP-CH-105 COURTHOUSE MEZZANINE SECURITY DEVICE PLAN SP-CH-106 COURTHOUSE SECOND FLOOR SECURITY DEVICE PLAN SP-CH-107 COURTHOUSE THIRD FLOOR SECURITY DEVICE PLAN SP-CH-108 COURTHOUSE FOURTH FLOOR SECURITY DEVICE PLAN SP-CA-101 COURTHOUSE ANNEX LOWER PARKING LEVEL SECURITY DEVICE PLAN SP-CA-102 COURTHOUSE ANNEX UPPER PARKING LEVEL SECURITY DEVICE PLAN SP-CA-103 COURTHOUSE ANNEX FIRST FLOOR SECURITY DEVICE PLAN SP-CA-104 COURTHOUSE ANNEX SECOND FLOOR SECURITY DEVICE PLAN SP-CA-105 COURTHOUSE ANNEX THIRD FLOOR SECURITY DEVICE PLAN SP-CA-106 COURTHOUSE ANNEX FOURTH FLOOR SECURITY DEVICE PLAN SP-CA-107 COURTHOUSE ANNEX FIFTH FLOOR SECURITY DEVICE PLAN SP-CA-108 COURTHOUSE ANNEX SIXTH FLOOR SECURITY DEVICE PLAN SP-CE-101 COURTHOUSE EXTENSION BASEMENT SECURITY DEVICE PLAN SP-CE-102 COURTHOUSE EXTENSION FIRST FLOOR SECURITY DEVICE PLAN SP-CE-103 COURTHOUSE EXTENSION SECOND FLOOR SECURITY DEVICE PLAN SP-CE-104 COURTHOUSE EXTENSION THIRD FLOOR SECURITY DEVICE PLAN SP-CE-105 COURTHOUSE EXTENSION FOURTH FLOOR SECURITY DEVICE PLAN SP-CE-106 COURTHOUSE EXTENSION FIFTH FLOOR SECURITY DEVICE PLAN SP-P-101 COUNTY PRISON 1ST FLOOR SECURITY DEVICE PLAN SP-P-102 COUNTY PRISON 1ST FLOOR MEZZANINE SECURITY DEVICE PLAN SP-P-103 COUNTY PRISON 2ND FLOOR SECURITY DEVICE PLAN SP-P-104 COUNTY PRISON 2ND FLOOR MEZZANINE SECURITY DEVICE PLAN SP-P-105 COUNTY PRISON 3RD FLOOR SECURITY DEVICE PLAN SP-P-106 COUNTY PRISON 3RD FLOOR MEZZANINE SECURITY DEVICE PLAN SP-J-101 JUVENILE CENTER LOWER LEVEL SECURITY DEVICE PLAN SP-J-102 JUVENILE CENTER UPPER LEVEL SECURITY DEVICE PLAN SP-911-101 911 CENTER 911 CENTER SECURITY DEVICE PLAN SP-M-101 MANOR SUB-GROUND SECURITY DEVICE PLAN SP-M-102 MANOR GROUND SECURITY DEVICE PLAN SP-M-103 MANOR FIRST FLOOR SECURITY DEVICE PLAN SP-M-104 MANOR SECOND FLOOR SECURITY DEVICE PLAN SP-M-105 MANOR THIRD FLOOR SECURITY DEVICE PLAN SP-M-106 MANOR FOURTH FLOOR SECURITY DEVICE PLAN SP-F-101 FORENSICS CENTER SITE SECURITY DEVICE PLAN SP-F-102 FORENSICS CENTER LOWER LEVEL SECURITY DEVICE PLAN SP-F-103 FORENSICS CENTER UPPER LEVEL SECURITY DEVICE PLAN SP-R-101 ROAD GARAGE ROAD GARAGE SECURITY DEVICE PLAN DRAWING LIST 1. PROVIDE A TURNKEY UNIFIED SECURITY SOLUTION FOR REPLACEMENT AND UPGRADE OF THE SECURITY SYSTEM AS SHOWN ON THE DRAWINGS AND OUTLINED IN THE SPECIFICATIONS, AND AS INDICATED IN THE CAMERA, READER, INPUT AND OUTPUT SCHEDULES (ATTACHED TO THE SPECIFICATIONS). 2. REFER TO THE SPECIFICATIONS FOR GENERAL, PRODUCTS AND EXECUTION REQUIREMENTS. 3. REFER TO THE NOTES TO SHEETS FOR SPECIFIC REQUIREMENTS BY DEVICE OR EQUIPMENT LOCATION AS SHOWN ON THE DRAWINGS. 4. CERTAIN EXISTING DEVICES SHALL BE RE-USED AND OTHER EXISTING DEVICES SHALL BE REPLACED AS OUTLINED IN THE LEGEND, NOTED ON THE DRAWINGS AND ADDRESSED IN THE SPECIFICATIONS. 5. PROVIDE NEW DEVICES, SOFTWARE, EQUIPMENT AND CABLING AS SHOWN ON THE DRAWINGS AND OUTLINED IN THE SPECIFICATIONS. 6. REUSE EXISTING CONDUIT AND BACKBOXES WHEREVER POSSIBLE. PROVIDE CONDUIT FOR NEW DEVICES AND EQUIPMENT TO INCLUDE DEVICE BACKBOXES AND CONDUIT AS REQUIRED TO CONCEAL AND PROTECT CABLING IN EXPOSED AREAS AND EXTERIOR LOCATIONS. FIELD VERIFY EXISTING CONDITIONS AND CONDUIT REQUIREMENTS. REFER TO THE SPECIFICATIONS FOR CONDUIT REQUIREMENTS. 7. PROVIDE 120VAC HARD-PIPED TO NEW ACCESS CONTROL PANELS AND POWER SUPPLIES. 8. PROVIDE CABLE AND CABLE MANAGEMENT TO SECURITY DEVICES AND EQUIPMENT TO INCLUDE CARD READERS, ELECTRIC LOCKS, INPUTS, OUTPUTS, SERVERS, WORKSTATIONS, BADGE PRINTERS, INTERCOMS AND CAMERAS. 9. CERTAIN DEVICES ARE IDENTIFIED AS ALTERNATES ON THE PLANS AND IN THE SPECIFICATIONS. THESE MANDATORY ALTERNATES WILL BE CONSIDERED FOR PURCHASE AND IMPLEMENTATION, BUT MAY OR MAY NOT BE INCLUDED IN THE PROJECT. PROVIDE ALTERNATES ONLY AS APPROVED IN WRITING BY THE OWNER. 10. FIELD VERIFY EXISTING CONDITIONS. 11. ALL WORK SHALL BE IN ACCORDANCE WITH STATE AND NATIONAL CODE AND AS REQUIRED BY AUTHORITIES HAVING LOCAL JURISDICTION. GENERAL NOTES: 09-28-20 PROVIDE NEW ACCESS CONTROL PANEL(S) AND POWER SUPPLIES. FIELD VERIFY EXACT SPACE AVAILABLE AND MOUNTING CONDITIONS. PROVIDE CONDUIT, GUTTERS AND 120VAC AS NECESSARY TO ACCOMODATE NEW PANELS. PROVIDE NEW BADGE PRINTER. PROVIDE NEW BADGING WORKSTATION. PROVIDE NEW CARD READER. PROVIDE NEW DOOR CONTACT. PROVIDE NEW DURESS ALARM BUTTON. PROVIDE NEW DOOR MANAGEMENT ALARM UNIT. PROVIDE NEW DOOR RELEASE BUTTON. PROVIDE DIRECTORY SERVER. PROVIDE NEW EXIT ALARM UNIT. PROVIDE ELECTROMAGNETIC LOCK. PROVIDE EMERGENCY RELEASE STATION. PROVIDE ELECTRIC STRIKE. PROVIDE CRASHBAR WITH ELECTRIC TRIM AND INTEGRAL REQUEST-TO-EXIT SWITCHES. PROVIDE VIDEO INTERCOM MASTER. PROVIDE INTERCOM SERVER. PROVIDE LOCAL ALARM SOUNDER. PROVIDE OVERHEAD DOOR CONTACT. PROVIDE REQUEST-TO-EXIT MOTION SENSOR. PROVIDE SURFACE CONTACT. PROVIDE UNIFIED SECURITY WORKSTATION. PROVIDE VIDEO ARCHIVE SERVER. PROVIDE VIDEO INTERCOM STATION. PROVIDE FIXED NETWORK CAMERA. PROVIDE ALTERNATE PRICING FOR OPERATIONS RELATED NEW FIXED NETWORK CAMERA. PROVIDE 180 DEGREE NETWORK CAMERA. PROVIDE 360 DEGREE NETWORK CAMERA. CR D D DR ES RX N N N NEW SECURITY DEVICES DM VIC LA SWS EM A OD EA ICM ER ET DS ICS SC ACP BP BWS VAS rev. a
Transcript
Page 1: Security Legend Westmoreland County

Westmoreland County

Security Legend

NTS

MR

SP-LEGEND

SECURITY PLAN

BD

ACPe

CRe

De

De

DVRe

ERe

ESe

KPe

LAe

Me

NVRe

RXe

Te

Xe

VWSe

REPLACE EXISTING ACCESS CONTROL WORKSTATIONEXCEPT AT MANOR.

REPLACE EXISTING ACCESS CONTROL PANEL(S) EXCEPTAT MANOR.

DELETE EXISTING BADGE PRINTER.

REUSE EXISTING CARD READER AT ALL FACILITIESEXCEPT AT THE JUVENILLE DETECTION CENTER.

REUSE EXISTING CARD READER WITH KEYPAD AT ALLFACILITIES EXCEPT AT JUVENILLE DETENTION CENTER.

REUSE EXISTING DOOR CONTACT.

REUSE EXISTING DURESS ALARM BUTTON.

REUSE EXISTING DELAYED EGRESS LOCK.

REUSE EXISTING DOOR RELEASE BUTTON.

DELETE EXISTING DIGITAL VIDEO RECORDER EXCEPT FORSUPPORT OF CERTAIN EXISTING CAMERAS IN THECOURTHOUSE ANNEX. SEE ANNEX PLANS FOR CAMERALOCATIONS.

REUSE EXISTING ELECTRIC LOCKSET.

REPLACE EXISTING EMERGENCY RELEASE STATION.

REUSE EXISTING ELECTRIC STRIKE.

REPLACE EXISTING INTERCOM STATION.

EXISTING KEYPAD, SEE SHEET NOTES.

REUSE EXISTING LOCAL ALARM SOUNDER.

REUSE EXISTING ELECTROMAGNETIC LOCK.

REPLACE EXISTING MONITOR UNLESS NOTEDOTHERWISE.

REPLACE EXISTING NETWORK VIDEO RECORDER.

REUSE EXISTING REQUEST-TO-EXIT MOTION SENSOR.

EXISTING TELEPHONE: SEE SHEET NOTES.

REPLACE EXISTING VIDEO WORKSTATION

REPLACE EXISTING EXIT PUSHBUTTON.

REPLACE EXISTING FIXED CAMERA EXCEPT AT MANOR.

EXISTING PAN,TILT, ZOOM CAMERA: SEE SHEET NOTES.

REUSE EXISTING IP NETWORK CAMERA.

EXISTING FIXED CAMERA TO REMAIN ON EXISTINGVICON VIDEO SURVEILLANCE SYSTEM.

EXISTING SECURITY DEVICES

CKe

DEe

Ee

V

IP

AWSe

BPe

ICe

DRe

MONe

SHEET NAME LOCATION TITLE

SP-LEGEND ALL BUILDINGS SECURITY LEGEND

SP-DET-201 ALL BUILDINGS SYSTEM DIAGRAMSP-DET-202 PRISON PRISON SYSTEM DIAGRAMSP-DET-203 COURTHOUSE ANNEX PARK POLICE DESK SECURITY LAYOUTSP-DET-204 ALL BUILDINGS WHERE APPLICABLE ACCESS CONTROL PANEL RISER DIAGRAMSSP-DET-205 ALL BUILDINGS WHERE APPLICABLE SECURITY DEVICE DIAGRAMSSP-DET-206 ALL BUILDINGS WHERE APPLICABLE ACCESS CONTROL ROUGH-INS DRAWING #1SP-DET-207 ALL BUILDINGS WHERE APPLICABLE ACCESS CONTROL ROUGH-INS DRAWING #2SP-DET-208 ALL BUILDINGS WHERE APPLICABLE CAMERA ROUGH-INS DRAWING #1SP-DET-209 ALL BUILDINGS WHERE APPLICABLE CAMERA ROUGH-INS DRAWING #2

SP-CH-101 COURTHOUSE EAST ELEVATIONSP-CH-102 COURTHOUSE WEST ELEVATIONSP-CH-103 COURTHOUSE BASEMENT SECURITY DEVICE PLANSP-CH-104 COURTHOUSE FIRST FLOOR SECURITY DEVICE PLANSP-CH-105 COURTHOUSE MEZZANINE SECURITY DEVICE PLANSP-CH-106 COURTHOUSE SECOND FLOOR SECURITY DEVICE PLANSP-CH-107 COURTHOUSE THIRD FLOOR SECURITY DEVICE PLANSP-CH-108 COURTHOUSE FOURTH FLOOR SECURITY DEVICE PLAN

SP-CA-101 COURTHOUSE ANNEX LOWER PARKING LEVEL SECURITY DEVICE PLANSP-CA-102 COURTHOUSE ANNEX UPPER PARKING LEVEL SECURITY DEVICE PLANSP-CA-103 COURTHOUSE ANNEX FIRST FLOOR SECURITY DEVICE PLANSP-CA-104 COURTHOUSE ANNEX SECOND FLOOR SECURITY DEVICE PLANSP-CA-105 COURTHOUSE ANNEX THIRD FLOOR SECURITY DEVICE PLANSP-CA-106 COURTHOUSE ANNEX FOURTH FLOOR SECURITY DEVICE PLANSP-CA-107 COURTHOUSE ANNEX FIFTH FLOOR SECURITY DEVICE PLANSP-CA-108 COURTHOUSE ANNEX SIXTH FLOOR SECURITY DEVICE PLAN

SP-CE-101 COURTHOUSE EXTENSION BASEMENT SECURITY DEVICE PLANSP-CE-102 COURTHOUSE EXTENSION FIRST FLOOR SECURITY DEVICE PLANSP-CE-103 COURTHOUSE EXTENSION SECOND FLOOR SECURITY DEVICE PLANSP-CE-104 COURTHOUSE EXTENSION THIRD FLOOR SECURITY DEVICE PLANSP-CE-105 COURTHOUSE EXTENSION FOURTH FLOOR SECURITY DEVICE PLANSP-CE-106 COURTHOUSE EXTENSION FIFTH FLOOR SECURITY DEVICE PLAN

SP-P-101 COUNTY PRISON 1ST FLOOR SECURITY DEVICE PLANSP-P-102 COUNTY PRISON 1ST FLOOR MEZZANINE SECURITY DEVICE PLANSP-P-103 COUNTY PRISON 2ND FLOOR SECURITY DEVICE PLANSP-P-104 COUNTY PRISON 2ND FLOOR MEZZANINE SECURITY DEVICE PLANSP-P-105 COUNTY PRISON 3RD FLOOR SECURITY DEVICE PLANSP-P-106 COUNTY PRISON 3RD FLOOR MEZZANINE SECURITY DEVICE PLAN

SP-J-101 JUVENILE CENTER LOWER LEVEL SECURITY DEVICE PLANSP-J-102 JUVENILE CENTER UPPER LEVEL SECURITY DEVICE PLAN

SP-911-101 911 CENTER 911 CENTER SECURITY DEVICE PLAN

SP-M-101 MANOR SUB-GROUND SECURITY DEVICE PLANSP-M-102 MANOR GROUND SECURITY DEVICE PLANSP-M-103 MANOR FIRST FLOOR SECURITY DEVICE PLANSP-M-104 MANOR SECOND FLOOR SECURITY DEVICE PLANSP-M-105 MANOR THIRD FLOOR SECURITY DEVICE PLANSP-M-106 MANOR FOURTH FLOOR SECURITY DEVICE PLAN

SP-F-101 FORENSICS CENTER SITE SECURITY DEVICE PLANSP-F-102 FORENSICS CENTER LOWER LEVEL SECURITY DEVICE PLANSP-F-103 FORENSICS CENTER UPPER LEVEL SECURITY DEVICE PLAN

SP-R-101 ROAD GARAGE ROAD GARAGE SECURITY DEVICE PLAN

DRAWING LIST1. PROVIDE A TURNKEY UNIFIED SECURITYSOLUTION FOR REPLACEMENT AND UPGRADEOF THE SECURITY SYSTEM AS SHOWN ON THEDRAWINGS AND OUTLINED IN THESPECIFICATIONS, AND AS INDICATED IN THECAMERA, READER, INPUT AND OUTPUTSCHEDULES (ATTACHED TO THESPECIFICATIONS).

2. REFER TO THE SPECIFICATIONS FORGENERAL, PRODUCTS AND EXECUTIONREQUIREMENTS.

3. REFER TO THE NOTES TO SHEETS FORSPECIFIC REQUIREMENTS BY DEVICE OREQUIPMENT LOCATION AS SHOWN ON THEDRAWINGS.

4. CERTAIN EXISTING DEVICES SHALL BERE-USED AND OTHER EXISTING DEVICESSHALL BE REPLACED AS OUTLINED IN THELEGEND, NOTED ON THE DRAWINGS ANDADDRESSED IN THE SPECIFICATIONS.

5. PROVIDE NEW DEVICES, SOFTWARE,EQUIPMENT AND CABLING AS SHOWN ON THEDRAWINGS AND OUTLINED IN THESPECIFICATIONS.

6. REUSE EXISTING CONDUIT AND BACKBOXESWHEREVER POSSIBLE. PROVIDE CONDUIT FOR NEW DEVICES AND EQUIPMENT TOINCLUDE DEVICE BACKBOXES AND CONDUITAS REQUIRED TO CONCEAL AND PROTECTCABLING IN EXPOSED AREAS AND EXTERIORLOCATIONS. FIELD VERIFY EXISTINGCONDITIONS AND CONDUIT REQUIREMENTS. REFER TO THE SPECIFICATIONS FOR CONDUITREQUIREMENTS.

7. PROVIDE 120VAC HARD-PIPED TO NEWACCESS CONTROL PANELS AND POWERSUPPLIES.

8. PROVIDE CABLE AND CABLE MANAGEMENTTO SECURITY DEVICES AND EQUIPMENT TOINCLUDE CARD READERS, ELECTRIC LOCKS,INPUTS, OUTPUTS, SERVERS, WORKSTATIONS,BADGE PRINTERS, INTERCOMS AND CAMERAS.

9. CERTAIN DEVICES ARE IDENTIFIED ASALTERNATES ON THE PLANS AND IN THESPECIFICATIONS. THESE MANDATORYALTERNATES WILL BE CONSIDERED FORPURCHASE AND IMPLEMENTATION, BUT MAYOR MAY NOT BE INCLUDED IN THE PROJECT. PROVIDE ALTERNATES ONLY AS APPROVED INWRITING BY THE OWNER.

10. FIELD VERIFY EXISTING CONDITIONS.

11. ALL WORK SHALL BE IN ACCORDANCE WITHSTATE AND NATIONAL CODE AND ASREQUIRED BY AUTHORITIES HAVING LOCALJURISDICTION.

GENERAL NOTES:

09-28-20

PROVIDE NEW ACCESS CONTROL PANEL(S) AND POWERSUPPLIES. FIELD VERIFY EXACT SPACE AVAILABLE ANDMOUNTING CONDITIONS. PROVIDE CONDUIT, GUTTERS AND120VAC AS NECESSARY TO ACCOMODATE NEW PANELS.

PROVIDE NEW BADGE PRINTER.

PROVIDE NEW BADGING WORKSTATION.

PROVIDE NEW CARD READER.

PROVIDE NEW DOOR CONTACT.

PROVIDE NEW DURESS ALARM BUTTON.

PROVIDE NEW DOOR MANAGEMENT ALARM UNIT.

PROVIDE NEW DOOR RELEASE BUTTON.

PROVIDE DIRECTORY SERVER.

PROVIDE NEW EXIT ALARM UNIT.

PROVIDE ELECTROMAGNETIC LOCK.

PROVIDE EMERGENCY RELEASE STATION.

PROVIDE ELECTRIC STRIKE.

PROVIDE CRASHBAR WITH ELECTRIC TRIM AND INTEGRALREQUEST-TO-EXIT SWITCHES.

PROVIDE VIDEO INTERCOM MASTER.

PROVIDE INTERCOM SERVER.

PROVIDE LOCAL ALARM SOUNDER.

PROVIDE OVERHEAD DOOR CONTACT.

PROVIDE REQUEST-TO-EXIT MOTION SENSOR.

PROVIDE SURFACE CONTACT.

PROVIDE UNIFIED SECURITY WORKSTATION.

PROVIDE VIDEO ARCHIVE SERVER.

PROVIDE VIDEO INTERCOM STATION.

PROVIDE FIXED NETWORK CAMERA.

PROVIDE ALTERNATE PRICING FOR OPERATIONS RELATEDNEW FIXED NETWORK CAMERA.

PROVIDE 180 DEGREE NETWORK CAMERA.

PROVIDE 360 DEGREE NETWORK CAMERA.

CR

D

D

DR

ES

RX

N

N

N

NEW SECURITY DEVICES

DM

VIC

LA

SWS

EM

A

OD

EA

ICM

ER

ET

DS

ICS

SC

ACP

BP

BWS

VAS

rev. a

Page 2: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

NTS

MR

SP-DET-201

SECURITY DETAILS

BD

WestmorelandCounty

COURTHOUSE COMPLEX LAN

MANOR LAN

PRISON LAN

WAN

911 LAN

ROAD GARAGE LAN

VIDEO ARCHIVE SERVER

DIRECTORY SERVER

INPU

T PO

INTS

INTELLIGENTCONTROLLER

OU

T PU

T PO

INTS

READ

ERS

VIDEO ARCHIVE SERVER

UPS

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UPS

ANNEX UPPER PARKING DATA ROOM

ANNEX 1ST FLOOR EXISTINGDVR/NVR ROOM

System Diagram

UNIFIEDWORKSTATION

UPS

UPS

UPS

UNIFIEDWORKSTATION

UPS

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

BADGE PRINTER

ANNEX 4TH FLOORSHERIFF'S DESK

ANNEX 1ST FLOORPARK POLICE CHIEF

ANNEX 1ST FLOORPARK POLICE CAPTAIN

INTERCOM SERVER

ANNEX 1ST FLOORHUMAN RESOURCES

UNIFIEDWORKSTATION

ANNEX 1ST FLOORPARK POLICE ADMIN

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES. SEE SECURITY DEVICE PLANS

FOR LOCATIONS

SEE SECURITYDEVICE PLANSAND EXHIBITSA AND B FORCARDREADERS,INPUTS ANDOUTPUTS.

VIDEO ARCHIVE SERVER

UPS

UNIFIEDWORKSTATION

SEE SECURITYDEVICE PLANSAND EXHIBITSA AND B FOR

CARDREADERS,

INPUTS ANDOUTPUTS.

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES.

INPU

T PO

INTS

INTELLIGENTCONTROLLER

OU

T PU

T PO

INTS

READ

ERS

SERVER ROOM

UNIFIEDWORKSTATION

UPS

ICM

ANNEX 1ST FLOORPARK POLICE DESK

DISPATCHSUPERVISOR

VIC

VIC

VEHICULARGATE

PEDESTAL

VIC

MAINENTRY

RECEPTION

ICM ICM

DISPATCHSUPERVISOR

AREA

ICM

SERVER ROOM

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UPS UPS

PARK POLICE DIRECTOR

VIDEO ARCHIVE SERVER

UPS

UNIFIEDWORKSTATION

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES.

SEE SECURITYDEVICE PLANSAND EXHIBITSA AND B FOR

CARDREADERS,

INPUTS ANDOUTPUTS.

INPU

T PO

INTS

INTELLIGENTCONTROLLER

OU

T PU

T PO

INTS

READ

ERS

JUVENILE CENTER

SEE SECURITYDEVICE PLANSAND EXHIBITSA AND B FOR

CARDREADERS,

INPUTS ANDOUTPUTS.

INPU

T PO

INTS

INTELLIGENTCONTROLLER

OU

T PU

T PO

INTS

READ

ERS

FORENSIC LAN

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES.

UNIFIEDWORKSTATION

UPS

RECEPTIONIST

VIDEO ARCHIVE SERVER

UPS

UNIFIEDWORKSTATION 1ST FLOOR SERVER CLOSET

CONFIGURE ALL(88EA) EXISTINGNETWORK CAMERASAND CONNECT WITHNEW GENETECSYSTEM. REFER TOSECURITY DEVICEPLANS FOR CAMERALOCATIONS ANDEXHIBIT D - EXISTINGMANOR CAMERA LIST.

1ST FLOOR SERVER CLOSET

UNIFIEDWORKSTATION

UPS

HUMAN RESOURCES

LOAD UNIFIED WEB CLIENTS ON EXISTING PC'S LOAD FULL UNIFIED CLIENTS ON EXISTING PC'S

PARK POLICE #1

PARK POLICE #2

IT RESOURCE #1

IT RESOURCE #2

DIRECTOR

ASSISTANT #1

ASSISTANT #2

COMPLIANCE

HUMAN RESOURCES

NURSING SUPERVISOR

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES.

VIDEO ARCHIVE SERVER

UPS

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UPS

SEE SECURITYDEVICE PLANSAND EXHIBITSA AND B FOR

CARDREADERS,

INPUTS ANDOUTPUTS.

INPU

T PO

INTS

INTELLIGENTCONTROLLER

OU

T PU

T PO

INTS

READ

ERS

COMPUTER/PHONE/SECURITY B11

LOWER LEVEL RECEPTIONIST

UNIFIEDWORKSTATION

UPS

UPPER LEVEL RECEPTIONIST

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UPS UPS UPS UPS

COUNSELOR RM131 COUNSELOR RM160 DIRECTOR RM109 ADMIN RM108

SEE DRAWING SP-DET-202 FORTHE PRISON SYSTEM DIAGRAM.

REFER TO SECURITY DEVICE PLANSAND CAMERA SCHEDULES FORCAMERA TYPES AND QUANTITIES. PROVIDE CAT CABLE FROMCAMERA TO POE PORT EXCEPTFOR MANOR WHICH WILLINCORPORATE THE EXISTINGCAMERAS AND CABLING IN PLACEAS IS. COORDINATE AND FIELDVERIFY EXACT PORT LOCATIONSWITH OWNER.

REFER TO SPECIFICATIONS FORSTORAGE REQUIREMENTS.

WORKSTATIONS FOR PARK POLICEDESK OPERATORS. SEE DRAWINGSP-DET-203 ANNEX PARK POLICEDESK AND SPECIFICATIONS FORDISPLAY REQUIREMENTS.

PROVIDE DESK TOP DISPLAY ANDMEDIUM WALL MOUNT DISPLAYWITH ARTICULATING MOUNT. SEESPECIFICATIONS FOR DISPLAYREQUIREMENTS.

TYPICAL - PROVIDE CAT CABLEFROM NEW SERVERS,WORKSTATIONS, UPS(S)INTELLIGENT CONTROLLERS ANDINTERCOMS. NOTE: CAT CABLE ISNOT REQUIRED AT EXISTINGCLIENTS SCHEDULED TO RECEIVEFULL UNIFIED CLIENTS OR WEBCLIENTS.

TYPICAL - PROVIDE WORKSTATIONAND DISPLAY(S) AS SHOWN ONTHE DRAWING AND OUTLINED INTHE SPECIFICATIONS.

TYPICAL - PROVIDE UPS(S) ASSHOWN ON THE DRAWING ANDOUTLINED IN THE SPECIFICATONS.

THE OWNER IS RESPONSIBLE FORTH LOCAL AREA NETWORK (LAN)TO INCLUDE NETWORKSWITCHES/POE PORTS ANDNETWORK CONFIGURATION ANDMANAGEMENT. COORDINATENETWORK REQUIREMENTS TOINCLUDE POE, BANDWIDTH AND IPADRESSES WITH THE OWNER.

THE OWNER IS RESPONSIBLE FORTHE WIDE AREA NETWORK (WAN)FOR SUPPORT OF THE SECURITYSYSTEM.

THE OWNER IS RESPONSIBLE FORNETWORK FROM FORENSICS TOMANOR AS NECESSARY FORSUPPORT AND RECORD OF THEFORENSIC CAMERAS ON THEARCHIVE SERVER LOCATED AT THEMANOR.

COORDINATE AND FIELD VERIFYEXISTING PC LOCATION WITHOWNER.

PROVIDE SYNERGIS CLOUD LINK ATEACH BUILDING.

THE INTENT OF THIS DIAGRAM ISTO CONVEY GENERAL SYSTEMINFORMATION AND MAY NOTINCLUDE ALL EQUIPMENTNECESSARY FOR DEPLOYMENT. FOR EXAMPLE, THE FINALQUANTITY OF ARCHIVE SERVERSSHALL BE BASED ON BANDWIDTHAND STORAGE CALCULATIONSPERFORMED BY THE SECURITYCONTRACTOR. REFER TO THESPECIFICATIONS FORREQUIREMENTS.

1

2

3

4

5

6

7

8

9

10

11

12

1

2

2

22

2

2

3

3

3

3

3

3

13

4

4

5 5

6

2

6

6

10

7

8

9

9

9

99

9

9

11

12

12

14

09-28-20

ANNEX LOWERPARKING GATE

ANNEX UPPERPARKING GATE

VIC

VIC

6

EXTENSION 1STFLR NORTH DOOR

PARKING GATE

VIC

rev. a

Page 3: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

Prison System Diagram

NTS

MR

SP-DET-202

SECURITY DETAILS

BD

WestmorelandCounty

VIDEO ARCHIVE SERVER

FAIL-OVER VIDEO ARCHIVE SERVER

VIDEO ARCHIVE SERVER

VIDEO ARCHIVE SERVER

UPS

UPS

UPS

UNIFIEDWORKSTATION

UPS

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UPS UPS

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UPS

PRISON LAN

UNIFIEDWORKSTATION

UPS UPS

UNIFIEDWORKSTATION

UPS

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

UNIFIEDWORKSTATION

SERVER ROOM

1ST FLOORCONTROL ROOM

J-UNIT CONTROL

K-UNIT CONTROL

E/F-UNIT CONTROL G/H-UNIT CONTROL

UPS UPS

UPS UPS

UPS UPS

2ND FLOORCONTROL ROOM

3RD FLOORCONTROL ROOM

WARDEN'S OFFICE

DEPUTY WARDEN

TRAINING LIEUTENANT #1

TRAINING LIEUTENANT #2

LOAD UNIFIED WEB CLIENTS ON EXISTING PC'S

DEPUTY WARDEN OF SECURITY #2

DEPUTY WARDEN OF TREATMENT

LIEUTENANT #1

LIEUTENANT #2

SERGEANT #1

SERGEANT #2

E/F HOUSING CONTROL

G/H HOUSING CONTROL

MAINTENANCE SUPERVISOR

OPERATIONS MANAGER

CANINE OFFICE

WARDEN

WIDE AREA NETWORK

WAN

EXISTING ALLEN BRADLEYLOGIX 5000

GENETEC/ALLEN BRADLEYSMART INTERFACE FOR ALARMMESSAGING FROM STAIRWELLCAMERAS ON ALLEN BRADLEY. SEE SECURITY SPECIFICATIONS.

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES.

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES.

N

N

N

SEE SECURITY DEVICEPLAN DRAWINGS ANDEXHIBIT C CAMERASCHEDULE FOR CAMERATYPES AND QUANTITIES.

SECURITY VLAN SECURITY VLAN

1

1

1

2

REFER TO SECURITY DEVICEPLANS AND CAMERASCHEDULES FOR CAMERATYPES AND QUANTITIES. PROVIDE CAT CABLE FROMCAMERA TO POE PORT. COORDINATE AND FIELDVERIFY EXACT PORT LOCATIONWITH OWNER.

COORDINATE AND FIELDVERIFY EXISTING PC LOCATIONWITH OWNER.

INTERFACE WITHALLEN-BRADLEY SYSTEM TODUPLICATE EXISTINGFUNCTIONALITY. REFER TOSPECIFICATIONS.

REFER TO SPECIFICATIONS FORSTORAGE REQUIREMENTS.PROVIDE ALTERNATE PRICINGTO INCREASE STORAGE ASOUTLINED IN THESPECIFICATIONS.

PROVIDE FAIL-OVER VIDEOARCHIVE SERVER.

TYPICAL - PROVIDE CAT CABLEFROM NEW SERVERS,WORKSTATIONS, UPS(S)INTELLIGENT CONTROLLERAND INTERFACE WITH ALLENBRADLEY. NOTE: CAT CABLE ISNOT REQUIRED AT EXISTINGCLIENTS SCHEDULED TORECEIVE UNIFIED WEB CLIENTS.

TYPICAL - PROVIDEWORKSTATION AND DISPLAY(S)AS SHOWN ON THE DRAWINGAND OUTLINED IN THESPECIFICATIONS.

TYPICAL - PROVIDE UPS(S) ASSHOWN ON THE DRAWINGAND OUTLINED IN THESPECIFICATONS.

THE OWNER IS RESPONSIBLEFOR NETWORK SWITCHES/POEPORTS AND NETWORKCONFIGURATION ANDMANAGEMENT. COORDINATENETWORK REQUIREMENTS TOINCLUDE POE, BANDWIDTHAND IP ADRESSES WITH THEOWNER.

THE INTENT OF THIS DIAGRAMIS TO CONVEY GENERALSYSTEM INFORMATION ANDMAY NOT INCLUDE ALLEQUIPMENT NECESSARY FORDEPLOYMENT. FOR EXAMPLE,THE FINAL QUANTITY OFARCHIVE SERVERS SHALL BEBASED ON BANDWIDTH ANDSTORAGE CALCULATIONSPERFORMED BY THE SECURITYCONTRACTOR. REFER TO THESPECIFICATIONS FORREQUIREMENTS.

3

4

4

4

5

6

7

8

NOTES TO SHEET

1

2

3

4

5

6

7

8

9

10

9

9

09-28-20

rev. a

Page 4: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

Courthouse AnnexPark Police DeskSecurity Layout

NTS

MR

SP-DET-203

SECURITY DETAILS

BD

WestmorelandCounty

EXISTING DESKFRONT VIEW

EXISTING DESKTOP VIEW

CONCRETE STRUCTURAL SLAB

LAY IN CEILING

COUNTER TOP

DESK TOP

DESK TOP

NEW 50-INCH DISPLAYS

NEW DISPLAY MOUNTS

NEW 19-INCH DISPLAYS

KEYBOARDS FOR NEW HIGH PERFORMANCEUNIFIED CLIENT WORKSTATIONS

NEW VIDEO INTERCOM DESKTOP MASTER

A B C D E

F

G

H

I

J

K

L

M

1. PROVIDE HIGH PERFORMANCEUNIFIED SECURITY WORKSTATIONSWITH HIGH PERFORMANCE VIDEOCARDS FOR SUPPORT OF DESKTOPDISPLAYS AND LARGE CEILINGMOUNT DISPLAYS. SEE DRAWINGSP-CA-103 FOR WORKSTATIONLOCATIONS.

2. PROVIDE INITIAL PROGRAMMINGAND CONFIGURATION FOR DISPLAYAS OUTLINED IN THE DISPLAYLOADING SCHEDULE SHOWN ONTHIS DRAWING.

3. PROVIDE CEILING MOUNTS,CUSTOM ADAPTERS, HARDWAREAND HEAVY DUTY FASTENERS ASREQUIRED TO PROVIDE A ROBUSTINSTALLATION FOR LARGE DISPLAYS.

4. LOAD BALANCE WORKSTATIONSAS REQUIRED FOR NEAR EQUALDISTRIBUTION OF VIDEO OUTPUTSBETWEEN THE TWOWORKSTATIONS.

5. PROVIDE WALL PENETRATIONS,SLEEVES, CONDUIT, CABLE, CABLEMANAGEMENT AND EXTENDERS ASREQUIRED FOR EXTENSION OFSIGNALS FROM WORKSTATIONS TODISPLAYS AND INPUT DEVICES.

6. PROVIDE PENETRATIONS, CABLEMANAGEMENT AND PERMANENTMECHANICAL FASTENERS ASREQUIRED FOR NEATLY ROUTINGCABLES UNDER DESKTOP WITHMINIMAL INTRUSION INTOOPERATOR'S KNEE SPACE.

7. FIELD VERIFY EXACT LOCATIONS,CONFIGURATIONS ANDPROGRAMMING REQUIREMENTSWITH OWNER AND ENGINEER.

8. DECOMISSION AND REMOVEEXISTING EQUIPMENT SCHEDULEDFOR REPLACEMENT WITH NEWEQUIPMENT. COORDINATE WITHOWNER FOR STORAGE OR DISPOSALOF DECOMISSIONED EQUIPMENT.

9. COORDINATE ALL WORK ANDSCHEDULES WITH THE OWNER TOMINIMIZE DISRUPTION TO EXISTINGOPERATIONS.

10. PROVIDE A DESKTOP INTERCOMMASTER STATION AND PROGRAMFOR VIDEO INTERCOMCOMMUNICATION CAPABILTY FROM911 CENTER AND ROAD GARAGEINTERCOMS BASED ON TIMESCHEDULE. COORDINATE WITHOWNER FOR SCHEDULEREQUIREMENTS BY LOCATION.

DISPLAY / PANE LETTER MONITORING DESCRIPTION

A 911 CENTER ENTRY GATE AND DRIVE CAMERA C-911-3B ACCESS CONTROL ALARM/EVENT CAMERA CALL UPSC ACCESS CONTROL ALARM MONITORING AND MANAGEMENTD ACCESS CONTROL ALARM/EVENT CAMERA CALL UPSE JUVENILE CENTER MAIN ENTRY CAMERAS C-JUL-1 AND C-JUL-2F COURTHOUSE COMPLEX - VERIFY CAMERAS WITH OWNERG COURTHOUSE COMPLEX - VERIFY CAMERAS WITH OWNERH COURTHOUSE COMPLEX - VERIFY CAMERAS WITH OWNERI COURTHOUSE COMPLEX - VERIFY CAMERAS WITH OWNERJ COURTHOUSE COMPLEX - VERIFY CAMERAS WITH OWNERK COURTHOUSE COMPLEX - VERIFY CAMERAS WITH OWNERL ROAD GARAGE MAIN ENTRY C-R-2L FORENSIC CENTER DELIVERIES C-F-7 AND PATHOLOGIST C-F-1M MANOR - VERIFY CAMERAS WITH OWNER

4. Program automatic camera callups based on alarms and events. See specifications.

INITIAL DISPLAY LOADING SCHEDULE

1. Coordinate final display loading and programming requirements with Owner.Notes:

2. Program individual display set up for up to four (4) Police Desk operators. 3. Adjust pane sizes and final layout as directed by Owner

09-28-20

Page 5: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

Access ControlPanel RiserDiagrams

NTS

MR

SP-DET-204

SECURITY DETAILS

BD

WestmorelandCounty

COURTHOUSE ANNEXCOURTHOUSE COURTHOUSE EXTENSION

JUVENILE CENTER911 CENTER ROAD GARAGE FORENSICS CENTER

TYPICAL NEW ACCESS CONTROL PANEL

EXISTING ANDNEW CARDREADERS

EXISTING ANDNEW DOORCONTACTS

LOCAL AREANETWORK

PORTEXISTING ANDNEW LOCKSAND CONTROLPOINTS

EXISTING ANDNEW REQUESTTO EXITDEVICES

READERS

DOORCONTACTS

REQUESTTO EXIT

LOCKS/OUTPUTS

INTELLIGENTCONTROLLER

2 READERSUB CONTROLLER

16 INPUT BOARD

16 OUTPUTBOARD

ETHERNET

READERS LOCKS/OUTPUTS

DOORCONTACTS

REQUESTTO EXIT

INPU

TS

OU

TPUTS

12/24VDCPOWERSUPPLY

FUSED O

UTPU

TS

120VACINPUT

BATTERYINPUT

HARD PIPE,HARDWIRE120VAC

4 HOURSBATTERYBACKUP

EXISTING AND NEWDOOR CONTACTS,DURESS BUTTONS,OVERHEAD DOORCONTACTS, EMERGENCY RELEASESTATIONS, DOORRELEASE BUTTONSAND ALARM INPUTS

EXISTING AND NEWCONTROL INPUTSINCLUDING EXITALARM BYPASSES,DOOR MANAGEMENTALARM BYPASSES,LOCAL ALARMSOUNDERS

INDIVIDUALLY FUSEDOUPUTS TO EXISTINGAND NEW LOCKS,REX MOTIONSENSORS,EMERGENCYRELEASE STATIONS,LOCAL ALARMSOUNDERS, EXITALARMS, DOORMANAGEMENTALARMS, REMOTECONTROL RELAYS

1. REFER TO FLOOR PLANS, CARD READER SCHEDULES ANDINPUT AND OUTPUT SCHEDULES FOR DEVICE TYPES ANDLOCATIONS.

2. THE DIAGRAM SHOWS TYPICAL REQUIREMENTS AND IS NOTINTENDED TO PROVIDE THE ACTUAL BOARD COUNTS OR FINALPANEL LAYOUT.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTS ANDPROVIDE ALL BOARDS, ENCLOSURES, POWER SUPPLIES ANDFUSED DISTRIBUTION MODULES AS NECESSARY TOACCOMODATE ALL CARD READERS, LOCKS, DEVICES, INPUTSAND OUTPUTS.

4. PROVIDE CABINET TAMPER SWITCHES FOR ALL ENCLOSURESAND WIRE/CONFIGURE FOR ALARM MONITORING.

DETAIL NOTES

LOWER PARKING

UPPER PARKING

1ST FLOOR

2ND FLOOR

3RD FLOOR

4TH FLOOR

5TH FLOOR

6TH FLOOR

DETAIL NOTES

ACPe ACPeACPe

OLD 911 ROOM

ELECTRICAL ROOM / WIRE CLOSET

ELECTRICAL ROOM / WIRE CLOSET

ELECTRICAL ROOM / WIRE CLOSET

ACPe ACPe

ACPeACPe

ACPe

DETAIL NOTES

DETAIL NOTES

BASEMENT

1ST FLOOR

2ND FLOOR

3RD FLOOR

4TH FLOOR

5TH FLOOR

ACPe

ELECTRICAL ROOM

ACPe

WIRE CLOSET

WIRE CLOSET

ACPeACPe

ACPeACPe

ACPe

NO EXISTING ACCESS CONTROL PANELSFOUND IN THE COURTHOUSE.

LOWER LEVEL

UPPER LEVEL

SERVER ROOM

ACPe

VESTIBULE

ACP

ACP

ACP

ACP

ACP

ACP

ACP

ACP

ACP

LOWER LEVEL

UPPER LEVEL PHONE / DATA ROOM 205

ACPe

ACP

COMPUTER / PHONE / SECURITY B11

ACPe ACPe ACPe ACPeACP

1. IT IS BELIEVED THAT THE EXISTING COURTHOUSECARD READERS, LOCKS AND DEVICES ARECONNECTED WITH THE EXISTING ACCESS CONTROLPANELS LOCATED IN THE UPPER PARKING OLD 911ROOM OF THE COURTHOUSE ANNEX. FIELD VERIFYTHE EXACT PANEL(S) LOCATION(S) AND PROVIDENEW ACCEES CONTROL PANELS AND POWERSUPPLIES FOR SUPPORT OF THE COURTHOUSE CARDREADERS, LOCK AND DEVICES AS REQUIRED.

2. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT AND OUTPUT SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTSAND PROVIDE ALL PANELS INCLUDING BOARDS,ENCLOSURES, POWER SUPPLIES AND FUSEDDISTRIBUTION MODULES AS NECESSARY TOACCOMODATE ALL CARD READERS, LOCKS, DEVICESAND INPUTS AND OUTPUTS.

1. THE DIAGRAM SHOWS EXISTING ACCESSCONTROL PANEL LOCATIONS AND IS NOT INTENDEDTO PROVIDE THE ACTUAL BOARD OR PANELREQUIREMENT COUNTS.

2. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT AND OUTPUT SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTSAND PROVIDE ALL BOARDS, ENCLOSURES, POWERSUPPLIES AND FUSED DISTRIBUTION MODULES ASNECESSARY TO ACCOMODATE ALL CARD READERS,LOCKS, DEVICES AND INPUTS AND OUTPUTS PLUS25% SPARE CAPACITY.

DEVICE LEGEND

ACPe

EXISTING ACCESS CONTROLPANEL(S) AND POWERSUPPLY(S) LOCATION. QUANTITIES SHOWN AREAPPROXIMATE. FIELD VERIFYEXACT LOCATION ANDQUANTITY. REFER TOSPECIFICATIONS FORREQUIREMENTS.

PROVIDE NEW ACCESSCONTROL PANEL(S) ANDPOWER SUPPLY(S) AND FUSEDOUTPUT DISTRIBUTION BOARDSAS REQUIRED TOACCOMMODATE ALL CARDREADERS, DEVICES, INPUTS ANDOUTPUTS PLUS 25% SPARECAPACITY. ICON REPRESENTSONE OR MULTIPLE ACCCESSCONTROL PANEL(S) ANDPOWER SUPPLY(S).

ACP

1. THE DIAGRAM SHOWS EXISTING ACCESSCONTROL PANEL LOCATIONS AND IS NOT INTENDEDTO PROVIDE THE ACTUAL BOARD OR PANELREQUIREMENT COUNTS.

2. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT AND OUTPUT SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTSAND PROVIDE ALL BOARDS, ENCLOSURES, POWERSUPPLIES AND FUSED DISTRIBUTION MODULES ASNECESSARY TO ACCOMODATE ALL CARD READERS,LOCKS, DEVICES AND INPUTS AND OUTPUTS PLUS25% SPARE CAPACITY.

DETAIL NOTES

1. THE DIAGRAM SHOWS EXISTING ACCESSCONTROL PANEL LOCATIONS AND IS NOT INTENDEDTO PROVIDE THE ACTUAL BOARD OR PANELREQUIREMENT COUNTS.

2. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT AND OUTPUT SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTSAND PROVIDE ALL BOARDS, ENCLOSURES, POWERSUPPLIES AND FUSED DISTRIBUTION MODULES ASNECESSARY TO ACCOMODATE ALL CARD READERS,LOCKS, DEVICES AND INPUTS AND OUTPUTS PLUS25% SPARE CAPACITY.

DETAIL NOTES

1. THE DIAGRAM SHOWS EXISTING ACCESSCONTROL PANEL LOCATIONS AND IS NOT INTENDEDTO PROVIDE THE ACTUAL BOARD OR PANELREQUIREMENT COUNTS.

2. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT AND OUTPUT SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTSAND PROVIDE ALL BOARDS, ENCLOSURES, POWERSUPPLIES AND FUSED DISTRIBUTION MODULES ASNECESSARY TO ACCOMODATE ALL CARD READERS,LOCKS, DEVICES AND INPUTS AND OUTPUTS PLUS25% SPARE CAPACITY.

DETAIL NOTES

1. THE DIAGRAM SHOWS EXISTING ACCESSCONTROL PANEL LOCATIONS AND IS NOT INTENDEDTO PROVIDE THE ACTUAL BOARD OR PANELREQUIREMENT COUNTS.

2. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT AND OUTPUT SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTSAND PROVIDE ALL BOARDS, ENCLOSURES, POWERSUPPLIES AND FUSED DISTRIBUTION MODULES ASNECESSARY TO ACCOMODATE ALL CARD READERS,LOCKS, DEVICES AND INPUTS AND OUTPUTS PLUS25% SPARE CAPACITY.

DETAIL NOTES

1. THE DIAGRAM SHOWS EXISTING ACCESSCONTROL PANEL LOCATIONS AND IS NOT INTENDEDTO PROVIDE THE ACTUAL BOARD OR PANELREQUIREMENT COUNTS.

2. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT AND OUTPUT SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

3. REFER TO SPECIFICATIONS FOR REQUIREMENTSAND PROVIDE ALL BOARDS, ENCLOSURES, POWERSUPPLIES AND FUSED DISTRIBUTION MODULES ASNECESSARY TO ACCOMODATE ALL CARD READERS,LOCKS, DEVICES AND INPUTS AND OUTPUTS PLUS25% SPARE CAPACITY.

09-28-20

Page 6: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

Security DeviceDiagrams

NTS

MR

SP-DET-205

SECURITY DETAILS

BD

WestmorelandCounty

1. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT SCHEDULES FOR DEVICETYPES AND LOCATIONS.

2. DEVICE SHOWN IN NORMAL STATE.

3. WIRE THE END-OF-LINE RESISTOR NETWORK ATTHE DEVICE TO PROVIDE SUPERVISION OF THE FIELDWIRE. REFER TO MANUFACTURER INSTRUCTIONSFOR RESISTOR VALUES AND CONFIGURATION.

4. WIRE DEVICE TO INPUT POINT AT THE SECURITY/ACCESS CONTROL PANEL.

DETAIL NOTES

SINGLE DOOR DOUBLE DOOR

CONCEALED DOOR CONTACT

SURFACE DOOR CONTACT

OVERHEAD DOOR CONTACT

1. REFER TO FLOOR PLANS, CARD READERSCHEDULES AND INPUT SCHEDULES FOR DEVICETYPES AND LOCATIONS.

2. DEVICE SHOWN IN NORMAL STATE.

3. WIRE THE END-OF-LINE RESISTOR NETWORK ATTHE DEVICE TO PROVIDE SUPERVISION OF THE FIELDWIRE. REFER TO MANUFACTURER INSTRUCTIONSFOR RESISTOR VALUES AND CONFIGURATION.

4. WIRE DEVICE TO INPUT AT THE SECURITY /ACCESS CONTROL PANEL.

DETAIL NOTES

DURESS ALARM BUTTON

DOOR RELEASE BUTTON

MAGNET

SECURITYPANEL INPUT

CONTACT

RESISTORNETWORK

MAGNET

SECURITYPANEL INPUT

MAGNET

CONTACTS

RESISTORNETWORK

SECURITYPANEL INPUT

BUTTON

RESISTORNETWORK

12VDC

SECURITYPOWERSUPPLY

SECURITYPANELINPUT

LOCK POWERSUPPLY+ -

FAILSAFE LOCK

REQUEST-TO-EXITMOTION SENSOR

1. REFER TO FLOOR PLANS AND CARD READER SCHEDULESFOR DEVICE TYPES AND LOCATIONS.

2. WIRE NORMALLY OPEN OUTPUT TO REQUEST-T0-EXIT (RX)INPUT AT SECURITY /ACCESS CONTROL PANEL.

3. WIRE FOR FAIL SAFE UNLOCK OF FAIL SAFE LOCKS SUCH ASELECTROMAGNETIC LOCKS AS REQUIRED BY CODE.

4. FOR FAIL SECURE LOCKS, DO NOT WIRE THE LOCKTHROUGH THE RX MOTION CONTACTS.

5. DEVICE AND LOCK POWER SHALL BE INDIVIDUALLY FUSED.

DETAIL NOTES

REQUEST-TO-EXITMOTION SENSOR

12VDC

SECURITYPANELINPUT

LOCK POWERSUPPLY+ -

FAILSAFE LOCK

PNEUMATICREQUEST-TO-EXIT

PUSH BUTTON

1. REFER TO FLOOR PLANS AND CARD READERSCHEDULES FOR DEVICE TYPES AND LOCATIONS.

2. WIRE NORMALLY OPEN OUTPUT TOREQUEST-T0-EXIT INPUT POINT AT SECURITY /ACCESSCONTROL PANEL.

3. WIRE FOR FAIL SAFE UNLOCK OF FAIL SAFE LOCKSSUCH AS ELECTROMAGNETIC LOCKS AS REQUIRED BYCODE.

4. LOCK POWER SHALL BE INDIVIDUALLY FUSED.

5. INTERFACE FOR FAIL SAFE UNLOCK ON FIRE ALARM.

DETAIL NOTES

REQUEST-TO-EXITPUSHBUTTON

12VDC

SECURITYPOWERSUPPLY

SECURITYPANELINPUT

LOCK POWERSUPPLY+ -

FAILSAFE LOCK

REQUEST-TO-EXITMOTION SENSOR

EMERGENCY RELEASESTATION

1. REFER TO FLOOR PLANS AND CARD READERSCHEDULES FOR DEVICE TYPES AND LOCATIONS.

2. WIRE NORMALLY OPEN OUTPUT TO ALARM INPUTPOINT AT SECURITY /ACCESS CONTROL PANEL. PROVIDE END OF LINE RESISTOR NETWORK (NOTSHOWN).

3. WIRE FOR FAIL SAFE UNLOCK OF FAIL SAFE LOCKSSUCH AS ELECTROMAGNETIC LOCKS AS REQUIRED BYCODE.

4. DEVICE AND LOCK POWER SHALL BE INDIVIDUALLYFUSED.

5. INTERFACE FOR FAIL SAFE UNLOCK ON FIRE ALARM.

DETAIL NOTES

EMERGENCY RELEASESTATION

SECURITYPOWERSUPPLY+ -

SECURITY/ACCESS CONTROLPANEL OUTPUT

LOCAL ALARM

SOUNDER

+-

1. REFER TO FLOOR PLANS AND CARD READERSCHEDULES FOR DEVICE TYPES AND LOCATIONS.

2. WIRE POWER THROUGH NORMALLY OPEN OUTPUTTO LOCAL ALARM SOUNDER.

3. DEVICE POWER SHALL BE INDIVIDUALLY FUSED.

4. PROGRAM ACCESS CONTROL/SECURITY OUTPUT TOFOLLOW ASSOCIATED DOOR ALARM STATUS SO THATTHE SOUNDER IS ACTIVATED ON DOOR FORCED OPENALARMS AND DOOR HELD OPEN ALARMS. PROGRAMDEVICE ACTIVATION TIME FOR DURATION OF DOORFORCED OR DOOR HELD TIME OR FIFTEEN SECONDS,WHICHEVER IS GREATER.

5. AT CARD READER DOORS, DOOR STATUS SHALL BESOFTWARE SHUNTED TO ALLOW ENTRY WITHOUTACTIVATION FOLLOWING A VALID CARD READ.

DETAIL NOTES

LOCAL ALARM SOUNDER

1. REFER TO FLOOR PLANS AND INPUT / OUTPUT SCHEDULES FOR DEVICE TYPES AND LOCATIONS.

2. WIRE ONE SET OF DOOR CONTACTS TO EXIT ALARM AND THE SECOND SET TO THE SECURITY PANEL.

3. WIRE FOR ALARM MONITORING OF THE EXIT ALARM OUTPUT.

4. WIRE FOR REMOTE BYPASS AND BYPASS STATUS MONITORING FROM THE SECURITY PANEL.

5. DEVICE POWER SHALL BE INDIVIDUALLY FUSED.

DETAIL NOTES

EXIT ALARM UNIT

MAGNET

SECURITYPANEL INPUT

DCINPUT

ALARMOUTPUT

BYPASSINPUT

RESISTORNETWORK

RESISTOR

CONTACT

CONTACT

DOOR CONTACTWITH DOUBLE POLE

DOUBLE THROWCONTACTS

SECURITY / ACCESS CONTROL PANEL

DCINPUT

ALARMINPUT

OUTPUT

12VDC

SECURITY POWER SUPPLY

BYPASSOUTPUT

ALARMINPUT

DOOR MANAGEMENT ALARM UNIT VALIDCARDREADINPUT

SECURITY / ACCESS CONTROL PANEL

DCINPUT

ALARMINPUT

OUTPUT

SECURITY POWER SUPPLY

MAGNET

RESISTOR

CONTACT

DOOR CONTACTWITH DOUBLE POLE

DOUBLE THROWCONTACTS

DCINPUT

ALARMOUTPUT

BYPASSINPUT

OUTPUT

12VDCBYPASSOUTPUT

ALARMINPUT

1. REFER TO FLOOR PLANS AND INPUT / OUTPUT SCHEDULES FOR DEVICE TYPES AND LOCATIONS.

2. WIRE ONE SET OF DOOR CONTACTS TO EXIT ALARM AND THE SECOND SET TO THE SECURITY PANEL.

3. WIRE FOR ALARM MONITORING OF THE EXIT ALARM OUTPUT.

4. WIRE FOR REMOTE BYPASS AND BYPASS STATUS MONITORING FROM THE SECURITY PANEL.

5. WIRE TO ALLOW PASSAGE THROUGH DOOR WITHOUT ALARM ON VALID CARD READ SIGNAL.

6. DEVICE POWER SHALL BE INDIVIDUALLY FUSED.

DETAIL NOTES

DOOR MANAGEMENT ALARM UNIT

EXIT ALARM UNIT

09-28-20

Page 7: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

Access ControlRough-Ins Drawing #1

NTS

MR

SP-DET-206

SECURITY DETAILS

BD

WestmorelandCounty

JBTO ACP

ARMORED CABLE

DETAIL NOTES

1. PROVIDE EXPOSED CONDUIT LOCATED INSIDE FENCED AREA AND ROUTED TO ACCESSIBLESPACE IN BUILDING. PROVIDE WEATHERPROOOF BOXES.

2. FIELD VERIFY EXISTING CONDITIONS

3. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS AND DOOR SWINGS.

SURFACE CONTACT FOR GATE APPLICATION3

NOTE: ALL CONDUITS TO BE 3/4" UNLESS OTHERWISE STATED

ROLL DOOR

CONTACTS

3/4 INCH CONDUIT

ROUTED TO

ACCESSIBLE CEILING

IN THE DIRECTION OF

ACP

SURFACE MOUNTED

4" JUNCTION BOX

OHDOD

1. PROVIDE EXPOSED CONDUIT LOCATED INSIDE SECURED AREA AND ROUTED TOACCESSIBLE SPACE IN BUILDING.

2. FIELD VERIFY EXISTING CONDITIONS

3. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS.

DETAIL NOTES

OVERHEAD CONTACT4

TO ACP

FINISHED FLOOR

FINISHED CEILINGFINISHED CEILING

4"-6"

STUB DOWNTHRU HEADER

JB

4" SQ JUNCTION BOXON SECURE SIDE

CONDUIT ONLY REQUIRED IN EXPOSEDCEILING OR NON-PLENUM SPACE

3/4" EMT-TYPICAL

PROVIDE WIRE PROTECTIONBUSHING AT END OF CONDUIT

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

3. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS AND DOOR SWINGS.

CONCEALED CONTACT1

FINISHED FLOOR

FINISHED CEILINGFINISHED CEILING

4"-6"

STUB DOWNTHRU HEADER

3/4" EMT-TYPICAL

TO ACP

JB

4" SQ JUNCTION BOXON SECURE SIDE

CONDUIT ONLY REQUIRED IN EXPOSEDCEILING OR NON-PLENUM SPACE

PROVIDE WIRE PROTECTIONBUSHING AT END OF CONDUIT

TO ACP

ARMORED CABLE

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

3. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS AND DOOR SWINGS.

SURFACE CONTACT2

FINISHED FLOOR

FINISHED CEILINGFINISHED CEILING

4"-6"

STUB DOWNTHRU HEADER

3/4" EMT-TYPICAL

DEVICE BOX

3/4" EMT-TYPICAL

CONDUIT ONLY REQUIRED IN EXPOSEDCEILING OR NON-PLENUM SPACE

STUB TO ACCESSIBLE SPACE ABOVECEILING OR CONNECT WITH CONDUITTO FAIL SAFE LOCK

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. PROVIDE BACKBOX SIZED TO ACCOMMODATE EMERGENCY RELEASE STATION OR EXITPUSHBUTTON AS APPLICABLE.

3. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

4. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS AND DOOR SWINGS.

42" OR MATCHEXISTING COND

EMERGENCY RELEASE OR EXIT PUSHBUTTON5

ROUTE CONDUIT ABOVE ACCESSIBLE CEILING

CEILING

PROVIDE 3/4" CONDUIT FROM BOX INTO ACCESSIBLE

CEILING SPACE AND CAP WITH NYLON BUSHING.

SECURE CABLE TO DESK WITH

PERMANENT STRAPS.

DOUBLE GANG BACKBOX WITH SINGLE GANG

RING. PROVIDE COVER WITH 1" CENTER HOLE

FINISHED FLOOR

1

CABLE

PANIC BUTTON OR REMOTE

RELEASE MOUNTED UNDER

SURFACE OF DESK.

ROUTE CONDUIT ABOVE ACCESSIBLE CEILING

DOUBLE GANG BACKBOX WITH SINGLE GANG

RING. PROVIDE COVER WITH 1" CENTER HOLE

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

3. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS.

CONDUIT IS REQUIRED ONLY WHERECABLE CANNOT BE FISHED ANDCONCEALED WITHIN WALLS

OR DOOR RELEASE

DURESS BUTTON OR DOOR RELEASE BUTTON6

09-28-20

Page 8: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

NTS

MR

SP-DET-207

SECURITY DETAILS

BD

WestmorelandCounty

Access ControlRough-InsDrawing #2

JB

TO ACP

3/4" EMT-TYPICAL

FINISHED FLOOR

FINISHED CEILINGFINISHED CEILING

6"-10" STUB DOWNTHRU HEADER

4" SQ JUNCTION BOXON SECURE SIDE

3/4" EMT-TYPICAL

RECESSED DOUBLE GANGBOX WITH SINGLE DEVICERING FOR CARD READER

RECESSED DOUBLE GANG TOSINGLE GANG MUD RING

MOUNTED HORIZONTALLYFOR REX ON SECURE SIDE

CONDUIT ONLY REQUIRED IN EXPOSEDCEILING OR NON-PLENUM SPACE

PROVIDE WIRE PROTECTIONBUSHING AT END OF CONDUIT

42" OR MATCHEXISTING COND

SURFACECONTACT

SECUREARMORED

CABLE

D

42" OR MATCHEXISTING COND

3/4" EMT-TYPICAL

BACKBOX FORCARD READER

BACKBOX FOR DOORMANAGEMENT UNITWHERE REQUIRED

BOX FORREX MOTION

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. PROVIDE BACKBOXES SIZED TO ACCOMMODATE CARD READER, DOOR MANAGEMENT ALARMUNIT AND REQUEST TO EXIT MOTION DETECTOR WHERE APPLICABLE.

3. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

4. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS AND DOOR SWINGS.

CARD READER WITH ELECTRIC STRIKE1

JB

FINISHED FLOOR

FINISHED CEILING

FINISHED FLOOR

FINISHED CEILING

4" SQ JUNCTION BOXON SECURE SIDE

4"-6"

RECESSED DOUBLE GANG BOX WITHSINGLE DEVICE RING FOR CARD READERON NON SECURE SIDE & RECESSED DOUBLEGANG DEEP BOX WITH SINGLE DEVICERING FOR REX BUTTON ON SECURE SIDE

3/4" EMT-TYPICAL

RECESSED DOUBLE GANG TOSINGLE GANG MUD RING

MOUNTED HORIZONTALLYFOR REX ON SECURE SIDE

3/4 " CONDUIT ONLY REQUIRED IN EXPOSEDCEILING OR NON-PLENUM SPACE

TO ACP

STUB DOWNTHRU HEADER

42" OR MATCHEXISTING COND

6"-10"

PROVIDE WIRE PROTECTIONBUSHING AT END OF CONDUIT

42" OR MATCHEXISTING COND

BACKBOXES FOR IN ANDOUT CARD READERS

BACKBOX FOR DOORMANAGEMENT ALARM

3/4" EMT-TYPICAL

CONDUIT AND BOXFOR MAGLOCK ANDDOOR CONTACT

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. PROVIDE BACKBOXES SIZED TO ACCOMMODATE CARD READER, DOOR MANAGEMENT ALARMUNIT AND REQUEST TO EXIT MOTION DETECTOR WHERE APPLICABLE.

3. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

4. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS AND DOOR SWINGS.

CARD READER IN AND OUT WITH MAGLOCK2

FINISHED FLOOR

FINISHED CEILINGFINISHED CEILING

4"-6"

STUB DOWNTHRU HEADER

3/4" EMT-TYPICAL

DEVICE BOX

3/4" EMT-TYPICAL

CONDUIT ONLY REQUIRED IN EXPOSEDCEILING OR NON-PLENUM SPACE

STUB TO ACCESSIBLE SPACE ABOVECEILING OR CONNECT WITH CONDUITTO FAIL SAFE LOCK

42" OR MATCHEXISTING COND

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. PROVIDE BACKBOX SIZED TO ACCOMMODATE VIDEO INTERCOM.

3. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

4. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS.

46"

VIDEO INTERCOM STATION3

FINISHED CEILINGFINISHED CEILING

4"-6"

STUB DOWNTHRU HEADER

3/4" EMT-TYPICAL

3/4" EMT-TYPICAL

CONDUIT ONLY REQUIRED IN EXPOSEDCEILING OR NON-PLENUM SPACE

STUB TO ACCESSIBLE SPACE ABOVECEILING OR CONNECT WITH CONDUTO FAIL SAFE LOCK

FINISHED FLOOR

BACKBOX FORETHERNET WALLPLATE

MATCH EXISTINGCONDITIONS

PROVIDE KEYSTONE JACK

DETAIL NOTES

1. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE SURFACE CONDUIT OR WIREMOLD TOABOVE ACCESSIBLE CEILING TO PROTECT CABLING AT ALL LOCATIONS WHERE CABLE CANNOT BEFISHED AND CONCEALED WITHIN WALLS.

2. PROVIDE BACKBOX SIZED TO ACCOMMODATE ETHERNET OUTLET.

3. CONDUIT IS NOT REQUIRED WHERE CABLE CAN BE FISHED AND CONCEALED WITHIN WALLS.

4. SEE SECURITY DEVICE PLANS FOR DEVICE LOCATIONS.

NETWORK WALL OUTLET FOR SECURITY WORKSTATIONS AND BADGE PRINTERS4

ACCESS CONTROL PANEL

3/4 INCH FIRE

TREATED

PLYWOOD

5 INCH

METAL

GUTTER

NETWORK

DROP

CONDUIT TO DEVICES120VAC POWER

FIRE ALARM

DRY CONTACT

SIGNAL

ACP

A1

A1

FA

ACP

SWH ULTRA BOARDS IN

LIFESAFETY POWER CABINET

36H X 30W X 4.5D (INCHES)

SWH ULTRA BOARDS IN

LIFESAFETY POWER CABINET

36H X 30W X 4.5D (INCHES)

ACCESS CONTROL PANEL

DIMENSIONS ARE APPROXIMATE

DIMENSIONS ARE APPROXIMATE

DETAIL NOTES

1. DETAIL REPRESENTS TYPICAL REQUIREMENTS FOR ACCESS CONTROL PANEL LOCATIONS. ACTUAL LAYOUT AND REQUIREMENTS VARY BY LOCATION BASED ON AVAILABLE WALL SPACE ANDEXISTING CONDITIONS.

2. FIELD VERIFY EXISTING CONDITIONS AND AVAILABLE WALL SPACE AND ADJUST LAYOUT ASREQUIRED.

3. EXTEND EXISTING 120VAC POWER OR PROVIDE NEW 120VAC CIRCUITS AS REQUIRED TOACCOMMODATE NEW ACCESS CONTROL PANELS AND POWER SUPPLIES.

4. PROVIDE NETWORK DROPS FOR SUPPORT OF NEW ACCESS CONTROL PANELS. FIELD VERIFYNETWORK SWITCH / PORT LOCATIONS WITH THE OWNER.

5. INTERFACE WITH FIRE ALARM FOR UNLOCK OF FAIL-SAFE LOCKS ON FIRE ALARM.

6. PROVIDE NEW ACCESS CONTROL PANELS AND LOW VOLTAGE POWER SUPPLIES WITH FUSEDOUTPUT POWER DISTRIBUTION BOARDS FOR SUPPORT OF ALL CARD READERS, INPUTS ANDOUTPUTS AS SHOWN ON THE SECURITY DEVICE DRAWINGS, AND AS OUTLINED IN THESPECIFICATIONS AND IN THE CARD READER, INPUT AND OUTPUT SCHEDULES..

7. PROVIDE 4HRS BATTERY BACKUP FOR CONTROL PANELS AND POWER SUPPLIES. PROVIDEBATTERY ENCLOSURES AS REQUIRED.

8. PROVIDE CABINET TAMPER SWITCHES FOR ALL ACCESS CONTROL PANELS AND POWER SUPPLIES. CONNECT AND CONFIGURE TAMPERS FOR ALARM MONITORING BY THE SECURITY SYSTEM.

9. PROVIDE FIRE TREATED PLYWOOD FOR MOUNTING CABINETRY AT LOCATIONS WHERE THERE ISNO SPACE AVAILABLE ON EXISTING PLYWOOD. FIELD VERIFY EXISTING CONDITIONS. PAINT TOMATCH.

10. PROVIDE GUTTER AND CONDUIT TO ABOVE ACCESSIBLE CEILING AND CABLE CHASES ASNECESSARY TO ACCOMODATE ALL CABLING. FIELD VERIFY EXISTING CONDITIONS AND PATHWAYS.

TYPICAL ACCESS CONTROL PANEL AND POWER SUPPLY REQUIREMENTS5

09-28-20

Page 9: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

Camera Rough-InsDrawing #1

NTS

MR

SP-DET-208

SECURITY DETAILS

BD

WestmorelandCounty

CAMERA IN LAY-IN CEILING TILE

4" SquareJ Box

Jack Chain OrWire To Ceiling Slab

Or Building Steel

1/2" FlexibleSteel Conduit

3/4" EMT ToHead End

4" Octagonal Box WithSusp Ceiling Support

NETWORKED DOME CAMERA

BACKBOX ATTACHEDTO T-BAR HANGER

CATCABLE

CABLE SUPPORTED UPHIGH, OFF SUSPENDEDCEILING

DETAIL NOTES

1. PROVIDE BACK BOX AND T-BAR HANGER TO SUPPORT CAMERA IN CEILING TILE.

2. PROVIDE MINIMUM 3FT SERVICE LOOP COILED AND SUPPORTED UP HIGH OFF THE CEILING.

SERVICE LOOP

1

4" SquareJ Box

Jack Chain OrWire To Ceiling Slab

Or Building Steel

1/2" FlexibleSteel Conduit

3/4" EMT ToHead End

4" Octagonal Box WithSusp Ceiling Support

NETWORKED DOME CAMERA

CATCABLE

CABLE SUPPORTED UPHIGH, OFF HARDCEILING

DETAIL NOTES

1. PROVIDE CUT-IN BACK BOX TO SUPPORT CAMERA IN HARD CEILING.

2. PROVIDE MINIMUM 3FT SERVICE LOOP COILED AND SUPPORTED UP HIGH OFF THE CEILING IFPOSSIBLE.

SERVICE LOOP

CAMERA IN HARD CEILING2

CUT-INBACKBOX

IP MinidomeCamera

FINISHED CEILING (IF APPLICABLE)

3/4" HoleThrough Wall

1/8" Toggle Bolt

CAT6 To Patch Panel

FINISHED FLOOR

DETAIL NOTES

1. FISH CAT CABLES CONCEALED WITHIN EXISTING WALLS WHERE POSSIBLE.

2. PROVIDE CABLE SUPPORTS ABOVE ACCESSIBLE CEILING.

CAT CABLE FISHED IN WALL

WALL MOUNTED CAMERA WITH FISHED CABLE3

Network DomeCamera

FINISHED FLOOR

Surface MountedIP Minidome

Camera

3/4" EMT ToHead End

Masonry WallNetwork DomeCamera

DETAIL NOTES

1. PROVIDE SURFACE MOUNT BACKBOX AND CONDUIT STUBBED UP TO ACCESSIBLESPACE.

2. PROVIDE CABLE SUPPORTS ABOVE ACCESSIBLE CEILING.

WALL MOUNTED CAMERA WITH SURFACE CONDUIT4

3/4" EMT

4" SquareJ Box

3/4" EMT ToHead End Or

To Spec RequirementCAT6 Cable

Wall Mount/PendantKit For Dome Cameras

3/4" ConduitThru Wall

Biscuit Jack In Junction Box-Patch Cord To Camera

FINISHED CEILING (IF APPLICABLE)

CAT Cable

DETAIL NOTES

1. PROVIDE CONDUIT TO ACCESSIBLE SPACE.

2. PROVIDE CABLE SUPPORTS ABOVE ACCESSIBLE CEILING.

EXTERIOR WALL MOUNTED CAMERA WITH ARM5

3/4" EMTLength Determined

By Application

4" Sq DeepJ Box

IP MinidomeCamera

Lock NutOn Both sides

3/4" EMT ToHead End

Network DomeCamera

DETAIL NOTES

1. PROVIDE CONDUIT TO ACCESSIBLE SPACE.

2. PROVIDE ADDITIONAL SUPPORTS ATTACHED TO BUILDINGSTRUCTURE FOR CONDUIT DROPS EXCEEDING 1FT.

3. PROVIDE WEATHERPROOF BOXES, CONNECTORS AND PROPERGASKETTING FOR LOCATIONS EXPOSED TO WEATHER. ENSURE ARAIN TIGHT SEAL.

4. FIELD VERIFY EXISTING CONDITIONS AND REQUIREMENTS.

PENDANT MOUNTED CAMERA6

09-28-20

Page 10: Security Legend Westmoreland County

A5

G2

GA GB GC GD GE GF GG GH

A1

ALTERNATIVE MODULE @ EAST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSTO ALLOW FOR 10' WIDE STALLS WITHOUTCOLUMN INTERFERENCE

STANDARD MODULE @ WEST SIDE OFGARAGE FITS BETWEEN FACE OF COLUMNSAND WALLS TO ALLOW FOR 10' WIDE STALLSWITHOUT COLUMN INTERFERENCE

UP

-22'-0"6.2% RAMP TO BASEMENT LEVEL 1

G3

G1

CAM

B2.5A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

MATC

H-LIN

E A-

A

A

B

C

D

E

F

2345678

2345678

AREA FOR

CHARTS AND

LEGENDS

General Notes

This document and all drawings, specifications, data, design concepts, workflow

processes, implementation strategies, configurations and other information

contained herein are the property of securadyne systems. Submittal by

securadyne systems does not convey any rights to the recipient, and all

intellectual or other property rights are reserved. The recipient may not use,

reproduce or disclose this document or its contents except as necessary for the

specific purposes contracted with securadyne systems . The recipient may not

use this document or its contents for manufacture, profit or sale, or installation by

contractors other than securadyne systems . Any unauthorized use or disclosure

without the prior written permission of securadyne systems is strictly prohibited.

Drawn By

Date

SSL Rep

Drawing Scale

Title

Client

REVISIONS

NO. DATE DESCRIPTION

1

A

B

C

D

E

F

Austin Office

11500 Metric Blvd Suite 290 Austin,

Texas 78758

Phone: (512) 835-8800

MS

None

TGM

11/17/2017

SECURITY LAYOUT

FLOOR PLAN

GARAGE - BASEMENT 2

Texas Mutual

Insurance

2200 Aldrich Street

Austin, TX 78723

Date Drawing Scale

Drawn By Checked By

1

Securadyne Project No. Sheet

GARAGE BASEMENT 2

CPSO-10414

Texas Mutual Insurance-36X48.dwg

Drawing No.

NTS

MR

SP-DET-209

SECURITY DETAILS

BD

WestmorelandCounty

Camera Rough-InsDrawing #2

Weather ProofJ Box

Wall Mount/PendantKit For Dome Cameras Liquid Tite

Conduit

Corner MountBracket

Drilled Hole ThruWall Above

Finished Ceiling

Corner MountBracket

Weather ProofJ Box

Wall Mount/PendantKit For Dome Cameras

Liquid TiteConduit

FINISHED CEILING (IF APPLICABLE)FINISHED CEILING

DETAIL NOTES

1. PROVIDE CABLE SUPPORTS ABOVE ACCESSIBLE CEILING.

2. FIELD VERIFY EXISTING CONDITIONS AND PROVIDE MOUNTING SUPPORTS /BACKING AS NECESSARY FOR RIGID INSTALLATION OF CORNER BRACKET FORNON-CONCRETE WALL APPLICATIONS.

TOP VIEW

FRONT VIEW

CORNER MOUNT CAMERA1

dant Mount Forti DirectionalCamera

ParapetMount

4" Square WeatherProof J Box

Liquid TiteConduit

CAT6 Cable ToHead End

CAT6 Patch Cord CAT6Biscuit Jack

Roof PenetrationBy Others

FINISHED CEILING (IF APPLICABLE)

ParapetMount

Roof PenetrationBy Others

4" Square WeatherProof J Box

Liquid TiteConduit

0/360 Cameraendant Mount

Network DomeCamera

Network DomeCamera

CAT Cable

DETAIL NOTES

1. PROVIDE CABLE SUPPORTS ABOVE ACCESSIBLE CEILING.

2. RE-USE EXISTING CONDUITS, WEATHERPROOF BOXES, ROOF PENETRATIONSAND SLEEVES WHEREVER POSSIBLE.

3. DO NOT PENETRATE THE ROOF OR ROOF MEMBRANE WITHOUT PRIORWRITTEN APPROVAL FROM THE OWNER.

4. ADJUST THE INSTALLATION TO MAKE BEST USE OF EXISTING MOUNTING STUDSAND PENETRATIONS WHERE POSSIBLE TO REDUCE ANY UNECESSARYPENETRATIONS IN THE WALL OR ROOF. FIELD VERIFY EXISTING CONDITIONS ANDENSURE PREAPPROVAL FOR WORK PLAN PRIOR TO COMMENCEMENT OF WORK.

SIDE VIEW

TOP VIEW

REUSE EXISTING ROOFPENETRATIONS AND CONDUITWHEREVER POSSIBLE

PARAPET MOUNT CAMERA2

09-28-20


Recommended