+ All Categories
Home > Documents > Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control...

Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control...

Date post: 31-Mar-2015
Category:
Upload: dominic-gautney
View: 214 times
Download: 1 times
Share this document with a friend
Popular Tags:
12
Security Systems BU Communication Systems DCN SPCC PO CCE 08.12.20 04 ST/SEU-CO 1 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector RS 232 for: Facilities factory testing (diagnostics) direct PC control camera control remote control (Open interface) applications for: - Mimic panel (Microphone control) - Voting panel - Attendance registration - Intercom - Message Distribution I&O Manual
Transcript
Page 1: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 1

Central Control Unit (Com - ports) LBB3500/15

2 x 9-pin Sub-D connector RS 232 for: Facilities

factory testing (diagnostics) direct PC control camera control remote control (Open interface)

applications for:

- Mimic panel (Microphone control)

- Voting panel

- Attendance registration

- Intercom

- Message Distribution

I&O Manual

Page 2: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 2

Central Control Unit (Com - ports) LBB3500/15

Open interface applications for remote controller

The DCN system provides a facility for controlling microphones, microphone management modes, attendance registration and voting from a remote controller.

The remote controller can be custom built for a given application to control microphone activity - for example a push- button panel, with on/ off push-buttons and indicator. LEDs assigned to each microphone position can be used to control delegates microphones from a remote position.

The communication protocol is message based binary interface (i. e remote functions and update information).

Note: Before third parties can use the remote interface, the interface

must be enabled on the CCU by installing the LBB3587 key-disk.

- Only possible by using the LBB 3500/15 or /35

Page 3: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 3

CCU Trunk Communication Board (TCB-4) Key to symbols :

1 Jumper X14 (See Chapter 4.5.3 (Table 4.4))

2 S14 DIP- switches 1 - 8 (See Chapter 4.6 )

3 S10 Push- button switch to reset the Central Control Unit during servicing.

4 Three LEDs (left to right) green/ yellow/ red. Normally the green/ yellow LEDs flash in sequence, indicating the software is running. Red LED illuminates during system reset.

5 S9 DIP- switches 1 - 8 (See Chapter 4.5.2 (Table 4.3))

6 Yellow LED indicates Digital Signal Processing (DSP) software is running.

7 Connector for multi- trunk board (used only in the multi- CCU)

8 Sockets for inserting flash EPROM (even)

9 Sockets for inserting flash EPROM (odd)

Page 4: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 4

CCU Trunk Communication Board (TCB-4) Key to symbols :

10 SRAM back- up battery 3.6 V (life- time 5 years min.)

11 Jumper X13 (See Chapter 4.5.3 (Tables 4.4))

12 Fuse 3.15 amp (delayed)13 Connector for multi- trunk board (used only in

the multi- CCU)14 Serial RS232 Port 115 Serial RS232 Port 2

Page 5: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 5

Central Control Unit (Com - ports) LBB3500/15

LBB 3500/ 15 and LBB 3500/ 35 (TCB 4) Port 1 : DCN Control PC Port 2 : Camera Control

In a single (stand- alone) CCU system two serial COM- ports (Port 1 and Port 2) are available. Both ports can be individually configured.

NOTE: It is possible to select ‘Full’ protocol on both Port 1 and Port 2. However this is NOT recommended due to processing power and memory limitations.

Default settings are;•8 data bits•No parity check•1 Stop bit

Page 6: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 6

TCB-4 DIP Switch Settings

(default)

Page 7: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 7

Central Control Unit (Audio I/O) LBB3500/15

1. Asymmetrical Recorder In- & Outputs

2. 2 Asymmetrical line input connectors

3. Symmetrical or 2 Asymmetrical line outputs

1

3

2

Page 8: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 8

Central Control Unit (Audio I/O) LBB3500/15

1. Tape/cassette recorder input and output (Cinch-type)

Tape In Asym. nom. -33 dBV max. -3 dBV

Tape Out Asym. nom. -33 dBV max. -3 dBV

2. 2 Asymmetrical line input connectors (Cinch-type)

Line In Asym. nom. -18 dBV max. +12 dBV

3. Symmetrical/Asymmetrical line output connectors (Cinch-type)

Line Out Sym. nom. -12 dBV max. +18 dBV

Line Out Asym nom. -18 dBV max. +12 dBV

Page 9: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 9

Central Control Unit (Trunk Outlets) LBB3500/15

1. Red LED overload indicators

2. Trunk outlet used for loop-through of the trunk-line-cable

1

2

Trunk

Page 10: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 10

Central Control Unit (Trunk Outlets) LBB3500/15

Trunk outlets

For loop-through of the DCN trunk-line without regenerating the digital signal.

Power handling capacity maximum:

- 60 PCF per outlet

- 180 PCF total for the three outlets of the CCU.

PCF=<60 max.

Page 11: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 11

1. Mains socket with built-in fuse

Nominal

Mains voltage Mains fuse Power Consumption

220, 230, 240 V AC. T- 4A (slow blow) 350 W

105, 115 V, 125 V AC. T- 5A (slow blow)

Warning:

All units must be powered via an earthed mains outlet.

115V-T4A/230V-T2A

Extension Power Supply LBB4106/x0

I&O Manual

Page 12: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO CCE 08.12.2004 Central Control Unit (Com - ports) LBB3500/15 2 x 9-pin Sub-D connector.

Security Systems BU Communication Systems

DCN SPCC PO CCE08.12.2004 ST/SEU-CO 12

Central Control Equipment

End of section

Robert Bosch GmbH

All rights are reserved. Reproduction or passing on to

third parties in whole or in parts is prohibited without the

written consent of the copyright owner.


Recommended