8
SEISMIC PROTECTION - VIBRATION CONTROL - SOUND INSULATION EXPERT SOLUTIONS www.dkminsaat.com INSULATION PROTECTION CONTROL MODULAR VIBR ATION ABSORBER
Transcript
Page 1: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …

SEISMIC PROTECTION - VIBRATION CONTROL - SOUND INSULATION

EXPERT SOLUTIONS

www.dkminsaat.com

INSULATIONPROTECTIONCONTROL

MODULAR VIBR ATION ABSORBER

Page 2: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …

DKM

2003Sound Insulation, Consulting and Application

2005Seismic ProtectionVibration Control

2004Mason Industries and

Mercer RubberRepresentative

2009Index Representative

2010Institutionalization 2011

Ankara Regional Representative

ISO 90012012Technical TrainingEvents 2013

Overseas MarketingTransactions2014

Research and Development Installation 2015

Manifacture - TunexWon encouragement award2016

Research and Development Projects

2020International Integration

2017New Products

2003Foundation

2023DKM 20. Year

Türkmenistan Aşkabat AquaticsCentre Swimming Pool

Page 3: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …

Safe

Comfortable

Innovative

Bursa Bosch Bodrum Eçzacıbaşı

Zorlu Center

Mersin Entegre Healthcare Campus

Istanbul 42 Maslak

Istanbul Taksim Divan Hotel

Istanbul Istinye Park Mall

İndex

Melamin

Üskudar - ÇekmekÖy Subway LineKartal Kaynarca Subway Line

Spine Tower

Türkmenistan Aşkabat AquaticsCentre Swimming Pool

Page 4: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …

Airborne Sound Insulation

Rw 65 - 66

Impact Sound Insulation

∆Lw 21 - 23

TUNEX was awarded as“Impact Sound Insulation Material” at“Innovative Sustainability Applications”contest which is organized by SKD

Page 5: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …

The impact sound insulation rubber base product which has been developped by DKM based on its experience and expertise in sound insulation prevents sound transition between floors in structures at highest level. Beside this, it contributes to heat insulation with its low heat transmission value. 5 mm and 8/4 mm of Tunex can properly be used under screed, carpet, hardwood, ceramic and 17/8 mm thick of Tunex is suitable under screed in mechanical volumes.

EXCELLENT SOLUTION OF SOUND AND HEAT INSULATION BETWEEN FLOORS

Product Characteristics

Thickness

Width x Length

Thermal Conductivity Coe�cient

Dynamic Sti�ness S’

∆Lw

∆Lw

IIC

-

-

TS EN 12667

TS EN 29052-1:1996

EN ISO 10140-3EN ISO 717-2TS EN 12354-2ASTM E2179-03

Standard

mm

m x m

W/mK

MN/m3

dB

Unit

5 - 8/4 - 17/8

1x10

0.047

≤23

21 - 23

3056 - 58

EN ISO 10140-3EN ISO 717-2 dB

20

Tunex Impact Sound Insulation Membrane

Water Vapour Di�usionResistance

TS EN 12086 - 20.24

IIC ASTM E2179-03

ASTM E90-09ASTM E413-10

55

STC 65

RwEN ISO 10140-2EN ISO 717-1

dB65 - 66

Fire Resistance

Sound Absorption Coe�cient(50 mm)

TS EN 13501-1

ISO 10534-2

-

Sabine

Bfl S2

0.74 500 Hz

Compressive Strength(At relative deformation %)

Service Temperature

10%

25%TS EN 826

-

kPa

kPa

-

2.39 - 4.94

2.83- 5.80

-40°C / +116°C

Airborne SoundReduction Value

Impact Sound ReductionValue – Under Screed

Impact Sound  ReductionValue – Under Hardfloor       

λ

μ

Characteristic of Tunex

• Contribution to Leed and Breeam Certification • Suitable for Noise and Energy Performance of Buildings Directives

• Environmentalist With %100 Recyclable• Fire-Resistant• Contribution to Sound Insulation

• Impact Sound Insulation IIC55 dB • Airborne Sound Insulation STC65 dB• Thermal Conductivity Coefficient 0.047 W/mK

Page 6: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …
Page 7: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …

Rezonex, Modular Vibration Absorber, is used to reduce noise and vibration are generated by high-frequency machines.

• Cooling Groups • Cooling Towers • Chiller• Compressors• Air Conditioning Plants

• Pumps• Generators• Transformers• Presses• Cellular Ventilators

VIBRATION IS UNDERCONTROL WITH REZONEX

Product Characteristics

Thickness

Width x Length

-

-

Standards

mm

cm x cm

Unit

12 22

30 x 30 45 x 45

Rezonex Modular Vibration Absorber

Service Temperature - - -40°C / +116°C

Rezonex

5 x 5

10 x 10

30 x 30

45 x 45

100 x 100

20% - 4.4 mm (deflection)

Load - Absorber Capacity

4.000

810

360

40

10

kgcm x cm

8.800

1.782

792

88

22

Ibs

30% - 6.6 mm (deflection)

Load - Absorber Capacity

8.000

1.620

720

80

20

kg

17.600

3.564

1.584

176

44

Ibs

40% - 8.8 mm (deflection)

16.000

3.240

1.440

160

40

Load - Absorber Capacity

kg

35.200

7.128

3.168

352

88

Ibs

MODULAR VIBR ATION ABSORBER

Page 8: SEISMIC PROTECTION - VIBRATION CONTROL - SOUND …

State of California – Health and Human Services Agency Arnold Schwarzenegger, Governor

Office of Statewide Health Planning and Development

Facilities Development Division

400 R Street, Suite 200 Sacramento, California 95811-6213

(916) 440-8300 Fax (916) 324-9188 www.oshpd.ca.gov/fdd

_______ _______

August 26, 2008

Mr. Richard Lloyd Mason Industries 2101 W. Crescent Ave. Suite D Anaheim, CA 92801

Subject: Mason Seismic Restraint Guidelines for Suspended Piping, Ductwork And Electrical Systems

OPA-0349 Dear Mr Lloyd:

Mason Industries’ Seismic Restraint Guidelines (OPA-0349) remains an acceptable reference for

California Hospital Projects. Should you wish to confirm this information, please contact the writer by

phone at: 916-440-8470 or via e-mail at: [email protected].

Sincerely,

Anthony R. Pike Senior Structural Engineer cc: File

Administration Buildings / Comprehensive BuildinsAkbank Operation CenterAlbaraka Turk Head OfficeAnadolu Head OfficeAnadolu Engine Production and Storage PlantsAnkara Cankaya Yapı Kredi Koray ConstructionCelikler ministry of environment and urbanisationRecreatinal Facility Building of Cerkezkoy Bosch Corlu Culture Congress CenterDogus Automotive Technology CenterEti Maden Head OfficeFinansbank Head Office Ford Otosan Garanti Bank Head Office Haberturk JournalHSBC Head OfficeIstanbul German ConsulateIstanbul Istinye USA EmbassyIstanbul Canada EmbassyIstanbul Naval Shipyard CommandMuratbey Daily Storage FacilitiesPhilip Morris KagithaneRenault Mais WarehouseSanko Holding Head OfficeTelekom Head OfficeTurk Telekom Ankara Head OfficeVehbi Koc FoundationThe Building Information CenterEducation Buildings29 Mayıs University Dorm BuildingPrime Ministry Head OfficeBilkent Holding Bilbak Blis SchoolBogazici University Rehabilitation CenterDogus UniversityOdtu Teknokent Sound BarrierSamsun Ted College Music RoomTurkish Education Foundation Music RoomsYeditepe University

ResidencesAntasya ResidenceCapital Vista Ankara D&TIstanbul Europe Residences KaleNidakule Levent/TahinciogluThe House Residence BomontiTomtom Gardens

YDA Nevbahar ResidenceNurolpark GunesliArma Tower AnkaraIstanbul Origin MaslakGoztepe Nida TowerRenaissance TowerTepe Dolpin

Shopping Centers41 Burda MallAydın Forum MallDiyarbakir Ceylan Karavil Bark MallEskisehir Neo MallIstanbul 212 MallIstanbul Akbati MallIstanbul Bayrampasa Real MallIstanbul Bostancı MallIstanbul Decathlon StoreIstanbul Istinye Park MallIstanbıl M1 Meydan Metro MallIstanbul Neomarin MallIstanbul Nisantasi City’s MallIstanbul Ozdilek MallIzmit Serdivan MallPodium Mall

Hotels / ResortsAntalya Merdan PalaceBodrum Swissotel Resort BeachBoursier Otel SisliCanakkale Akol HotelHoliday Inn KayseriIstanbul By HotelIstanbul Hilton HotelIstanbul Nisantası Sofa HotelIstanbul Sisli Marriott HotelIstanbul Taksim Divan HotelIzmır Bayraklı Hilton Garden InnKayseri Radisson BlueMalatya Hilton HotelSamsun Sheraton OtelSapanca Richmond Nua Wellness Spa HotelSteingenberher Airport HotelThe Greenpark Hotel Ankara

Healthcare Facilities / HospitalsIstanbul Acibadem HospitalIstanbul Gaziosmanpasa Ozel Ideal HospitalIstanbul Koc University Graduate School of Health Sciences HospitalIstanbul Taksim Acibadem HospitalKaradeniz Technical University Farabi Hospital Audiology RoomKosuyolu Hospital Project Mechanical StoreMersin Entegre Healthcare CampusYeditepe University Oncology Hospital

OverseasAzerbaijan Baku Eas SchoolAzerbaijan Baku Convention CenterAzerbaijan Baku Dynamo HotelAzerbaijan Baku Ganjlik MallAzerbaijan Baku Gosport BuildingAzerbaijan Baku Hilton HotelAzerbaijan Baku National Gymnasium ArenaAzerbaijan Baku Sofaz Office TowerAzerbaijan Baku Trump TowerAzerbaijan Baku White City ProjectAlgeria USA EmbassyEpik Construction Baghdat USA EmbassyGeorgia Batum HiltonGeorgia Tbilisi HotelIraq Divaniye StadiumIraq Duhok Family MallIraq Gulan TowerKazakhistan Talan TowersNepal USA EmbassyRussia Sochi Marriott HotelTajikistan Dusambe HotelTurkmenistan Ashgabat Airport Hotel BuildingAfghanistan Lakeshore Air Base ProjectUzbekistan Tashkent Hyatt Hotel

CombinedCapitol Vista Office Tower AnkaraEmaar SquareEti Maden Emet BorIstanbul 42 MaslakIstanbul Eclipse MaslakIstanbul Torun CenterIstanbul Zorlu CenterKonya Unilever Production FacilityKordsa Global R&D CenterMall of IstanbulMetropol IstanbukQuasar IstanbulRitim Istanbul

TransportationUskudar-Cekmekoy Subway LineAnkara High-Speed Train StationGebze-Halkali MarmarayKartal – Kaynarca Subway LineBodrum Airport

REFERENCES

DKM Construction and ConsultancyCevizli Mah. Bağdat Cad. No: 538 K:1 D:4 Maltepe 34846 İstanbul Türkiye T+90 216 508 20 50 F: +90 216 508 20 [email protected] www.dkminsaat.com


Recommended