+ All Categories
Home > Documents > Selection Software

Selection Software

Date post: 11-Jan-2022
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
16
FanCat Selection Software User Manual INNOVATION IS IN THE AIR
Transcript
Page 1: Selection Software

FanCat Selection Software

User Manual

INNOVATION IS IN THE AIR

Page 2: Selection Software

222 CONTENTS

Content Page

1. START SCREEN 3

1.1 MENU AND TOOLBARS 4

2. OPERATING POINT 6

2.1 DENSITY SETTINGS 7

2.2 SPEED AND MOTOR SPECIFICATIONS 7

2.4 ENERGY EFFICIENCY 7

2.5 CUSTOMER-SPECIFIC MEASUREMENTS 7

3. LIST OF RESULTS 8

4. DETAILS 10

5. WATCH LIST 11

6. DISPLAY OF CHARACTERISTIC CURVES 11

7. PRINT PREVIEW 13

8. SETTINGS - OPTIONS 14

9. INSTALLATION AND SETUP 15

10. GENERAL INFORMATION 15

Page 3: Selection Software

333

The FanCat computer catalogue is a modern software interface for the design of fans with

display of the operating results in preselected operating points. FanCat contains the Peerless

Blowers Synergy Series fans, based on performance measurements according to ISO 5801

and helps you quickly and reliably find the optimum fan for your operating point.

1. START SCREENA target-oriented pre-selection is offered on the start screen so that the suitable pro-

duct for the customer application can be found. FanCat is divided into four Tabs:

1. The Product Range tab for pre-selection.

2. The Fan Selection tab with the operating point input and the operating conditions.

3. The Details tab with detailed information.

4. The Watch List tab that summarizes the selection / evaluation and to request a quote.

You can navigate between the four tabs by using the arrow buttons.

By default, FanCat opens under the tab Product Range.

The Peerless Blowers fans are divided into four fan types:

1. Housed blowers

2. Axial blowers

3. Unhoused plug or plenum fans for use in a box (e.g. air handling unit)

4. Unhoused plug or plenum fans for use in a fan array, measured in a box with

dimension 1.5 x nominal wheel diameter.

Only one fan type can be selected. The right column product line shows the applicable fan

series based on the pre-selection.

Page 4: Selection Software

444 START SCREEN | MENU AND TOOLBARS

In the center column industry application one or more application areas can be selected. This

prevents a fan that is specifically designed for HVAC, for example, from being proposed for

use in industrial technology just because the fan reaches the required operating point.

Several industries or all industries can be selected. The result of the selection is displayed in

the column product lines. If you move the mouse pointer over the name of a series, an

information text is displayed which describes the series in more detail. You can activate or

deactivate all series with the respective button.

1.1 MENU AND TOOLBARSDepending on the functionality, a toolbar can be seen at the top and bottom of the four

tabs. The symbols indicate buttons that perform the following functions for quick operation:

1. Top Toolbar

Opens the user manual as a PDF document

Opens the Explorer to select a project that has already been saved

Opens a settings menu for different options

Page 5: Selection Software

555

2. Bottom Toolbar

Saves watch list as a file

Adds selected fan to watch list

Jumps to details view

Opens the characteristic curves display

Opens the layout folder for the print preview

3. Menu Bar

• File: „Save project“, „Open project“, „Set up printer“, „Preview printer“

• Options:: Settings mask, licensing and proxy settings

• Language:: Language /unit options for user interface / printer output (details p. 14)

• Help: Contains the user manual, link for email to Peerless Blowers and info window

about the application

Page 6: Selection Software

666 OPERATING POINT

2. OPERATING POINTIn the upper half of the tab fan selection the entries for the operating point and corre-

sponding parameters are made. Once an entry has been made, fans are searched and the

search result is displayed in the lower part of the tab in the result list.

For the selection, reference is always made to installation category A, static open inlet accor-

ding to ISO5801. The operating point is entered in the first field by specifying the volume flow

rate and pressure increase. The optional m3/s unit can be adjusted under „Language“.

If a speed is entered in the third field, a selection field for entering the tolerance is opened

when entering the flow rate. The selection of a tolerance is necessary, since a fan characteris-

tic curve at a given speed does not usually hit the operating point exactly, but runs close to

the operating point. The tolerance refers to the volume flow and is automatically converted to

the pressure. This results in a tolerance segment on the asset parabola that is highlighted in

red. In the fourth field. the selection can be limited by restricting the wheel diameter.

Page 7: Selection Software

777

2.1 DENSITY SETTINGSFor the operating point, the technical standard density of ρ= 1.205 kg/m3 at 20°C and

1013 hPa ambient pressure is proposed. Applicable values can be specified for air temperature

and altitude above sea level. With the input the density is immediately updated. A click on the

marked button sets the density back to standard density.

2.2 SPEED AND MOTOR SPECIFICATIONSFor fans that have an assigned motor, the nominal speed is known, so that the nominal

speed can be searched for here. When selecting fans, make sure that the appropriate motor

frequency is selected in the following field. A special feature is the“Variable speed“ setting.

With this setting, a slider is displayed with which the speed can be infinitely varied. The cha-

racteristic curves are recalculated and displayed. However, there is no new search of the fans

for the fulfilment of the operating point. The reason why the listed fans change in the speed

variation result list is that exclusion criteria, such as max. speed or search tolerance, are effec-

tive. When searching for fans, the selection can be made for 50 Hz or 60 Hz motors as well as

for all frequencies.

2.3 ENERGY EFFICIENCYHere you can set the ErP energy efficiency 2015 or the FEI limit. AMCA prescribes a mini-

mum FEI of 1.0. Only fans with ErP energy efficiency criteria, valid from YYYY or a FEI greater

than the set value are listed. Show all means that the ErP criteria or the FEI are not taken into

account for fan selection.

2.4 CUSTOMER-SPECIFIC MEASUREMENTS

If a customer has a license key for customer-specific measurements, the selection optio-

nally be limited to the fans measured for the customer.

Page 8: Selection Software

888 LIST OF RESULTS

3. LIST OF RESULTSThe list of results lists fans that were found based on the specifications. The 50 best fans

are listed according to the set sorting criterion.

The following search criteria can be selected:

• lowest noise level,

• highest efficiency

• smallest deviation from duty point

• smallest nominal diameter D2

• lowest speed

• minimum unit length

• smallest housing angle

• lowest shaft power

In the first column, the first four fans are marked by default with an icon for evaluation

and displayed with an activated radio button. The marking symbol identifies the characteristic

curves. The radio button can be activated or deactivated with a mouse click. The fans with the

activated option field are output in the characteristic diagrams or in the documents.

Page 9: Selection Software

999

After the first column, the following columns are displayed.

• fan identifiier

• housing angle in °

• Volume flow in the selected unit,

• Static pressure, free blowing,

• Total pressure,

• Sound pressure level at the specified distance, at 1m without indication if Lp was

measured,

• Sound power level at the specified distance, at 1m without specification if Lw was

measured,

• Preset or calculated speed,

• Shaft power of the fan when measured with a torque measuring shaft,

• Electrical active power of the motor when measured with an electrical power meter,

• Static efficiency related to the power rating,

• Total efficiency in relation to the power rating,

• Installation width with (G) for dimension over housing and (L) for dimension over

impeller

• FEI value, Fan Energy Index according to AMCA 208-18

• Result of the ErP analysis and note number described in the footer of the window.

Clicking the right mouse button on a line in the result list opens a context menu from

which additional information about the fan, including the maximum power, can be displayed

or pictures and data sheets can be obtained.

Page 10: Selection Software

101010 DETAILS

Clicking the last column „ErP, note“. opens a window showing the ErP data of the respec-

tive fan. To request a quotation or to compare several fans, the product must be added to the

watch list via the context menu. To request a quotation or to compare several fans, the pro-

duct must be added to the watch list via the context menu or the button add to watch list.

For fans, the identifier is preceded by an“F“ for fans, e.g. FDprime!

For a fan wall, the identifier is preceded by the number of fans, e.g. 4*FWDprime!

4. DETAILS

The tab details summarizes the information about the selected fans. The details tab dis-

plays one of two selections:

• the selected fans from the result list or

• the selected fans from the watch list.

The fans in the results list are added to the watch list using the add to watch list button.

If you jump from the watch list to the detailed view, the fans from the watch list are displayed

and the transfer to the watch list is blocked.

The following details are displayed:

• product series pictures in the top row

• a characteristic curve diagram with a green measuring line in the left column

• table with data at the green measuring line in the middle column

• an overview of available documents for the fan in the right column

Above the characteristic curve is a selection field in which the desired characteristic

curve can be selected. The measured value of this characteristic is shown in the table in the

right column.

Page 11: Selection Software

111111

5. WATCH LIST

The watch list is used to compare the selected fans. As in the result list, the data of the

fans are displayed here. The same evaluation functions of the characteristic display and the

layout folder apply as described. With the button send inquiry the standard mail program is

opened and the selection of the fans along with the selection criteria is attached as a project

file „Name.pfc“ to be sent to Peerless Blowers.

6. CHARACTERISTIC CURVE DISPLAY

The characteristic curves of the marked fans are displayed in a window by clicking on

the characteristic curves button. The type of characteristic can be set in the upper selection

field marked in red. The specified search tolerance is shown in red on the system parabola of

the operating point. The values at the intersections of the system parabola with the characte-

ristic curves (marked blue) are displayed in a table above the characteristic curves.

Clicking the right mouse button in the characteristics map opens a context menu. Two

options can be inserted there:

• show selected points or

• show intersections with system parabolas.

If show selected points is activated, you can then insert a vertical measurement line via

insert new point. The values at the intersection points of the line with the characteristic curves

are displayed in the table above the characteristic curves. Several measuring lines can be

drawn in and positioned with the mouse pointer to the left and right. The light green line is the

last moved line and is decisive for the bar chart sound pressure level at selected volume flow.

The table values at the intersections with the measurement lines can be transferred for out-

put in the layout folder under list of selected points.

Page 12: Selection Software

121212 CHARACTERISTIC CURVE DISPLAY

If show intersection points with system parabolas is activated, a further operating point

with a system parabola (green) can be inserted via insert new point. The intersections with the

characteristic curves (marked blue) are then also displayed in the table. The table values at

the intersection points with the system parabolas can be transferred for output in the layout

folder under list of intersection points with system parabolas.

• Shaft efficiency / Volume flow (V)

• Total shaft efficiency / Volume flow (V)

• Sound pressure level unweighted / Volume flow (V)

• A-weighted sound pressure level / Volume flow (V)

• Sound power level unweighted / Volume flow (V)

• Sound power level A-weighted / Volume flow (V)

• Torque / Volume flow (V)

• Static pressure number / figure of delivery φ

• Total pressure number / figure of delivery φ

• Figure of merit / figure of delivery φ

• Shaft efficiency / figure of delivery φ

• Total wave efficiency / figure of delivery φ

The characteristics can be copied to the clipboard or printed by clicking the respective

button.

Characteristic curve display with the

selectable characteristic curves for:

• Pressure free blowing / Volume flow (V)

• Total pressure / Volume flow (V)

• Shaft power / Volume flow (V)

Page 13: Selection Software

131313

7. PRINT PREVIEW

The print preview button takes you to the output of characteristic curves and tables. A

mask opens in which five layout folders can be selected. Any number of pages can be defined

in each folder for the output of the evaluations. The selection of the evaluations is made by

clicking the right mouse button in the white space.

The characteristic diagrams are placed on a DIN A4 sheet. in landscape format The posi-

tion of the mouse pointer determines where the characteristic diagram is placed.

• A click to the left or right of the center of the page adds a column to the page in

which the new diagram is placed.

• A click above or below the horzontal center line adds a row to the page in which the

new diagram is placed. A maximum of three characteristic line diagrams can be posi-

tioned one above the other.

• A mouse click in the grey space outside the sheet opens a new page.

Page 14: Selection Software

141414 OPTIONS | SETTINGS

In addition to the characteristic curves by volume flow and figure of delivery, the follo-

wing defined evaluations can be added:

• Data Sheet - adds the data sheet of the first marked fan. All available data sheets for

this fan are printed.

• List of selected points - a fixed table containing values at the intersections of the

vertical measurement lines with the characteristic curves.

• List of intersections with system parabolas - a table with values resulting at the inter-

sections of the system parabolas with the characteristic curves.

• Sound pressure or sound power level at selected flow rate - a bar chart with the

measured and converted sound pressure values or sound power values for the volu-

me flow at the activated measuring line (light green)

• Sound pressure or sound power level at the operating point -a bar chart with the

measured and converted sound pressure values or sound power values of the fan at

the operating point.

Finished button - Exiting with this button saves the defined printer output. The defined

outputs are automatically updated when the fans in the evaluation list are changed.

8. OPTIONS | SETTINGSClicking Options in the menu bar opens a window in which font and font size for the prin-

ter output can be selected.

The editor is entered with the date specification in the documents of the evaluations.

The second date field is used for preselection with a calendar function.

Various polynomial degrees can be selected for smoothing the characteristic curve. The

3rd or 5th degree polynomial degree is best suited.

Mark measurement values displays the measuring points with colored symbols in the

characteristic diagram.

Page 15: Selection Software

151515

The line widths can be set differently for the

screen display and for printing.

The text language can be set to English and

Russian for printing. In addition, American units can

be selected for the English edition.

By default, the legend for the characteristic

graphics is located at the bottom as footer text. This

can optionally be changed to header text.

The sound pressure values output are based

on the specified distance.

In the lower section of the setting screen you will find the information for the ErP analy-

sis. No entries need to be made here for fans with a permanently assigned motor.

Using the motor data, the corresponding efficiency is read from the Motor efficiencies

table and the ErP analysis is thus carried out.

9. INSTALLATION & SETUPFanCat is obtained via a link from the Peerless Blowers website. The installation of the

program file „Punker_FanCat.exe is placed in the program folder C:\Programme (86)\Pun-

ker_FanCat. The other folders for images and PDFs are created in the user directory under C:\

User\Name\AppData\Local\Punker_FanCat.

10. GENERAL INFORMATIONTechnical documents Peerless Blowers fan series

General Terms and Conditions of Sale

Page 16: Selection Software

Peerless Blowers

Madison Manufacturing Company, Inc.

172 South Andrews Ave. PO Box 187

Hot Springs, NC 28743-0187 USA

828-622-7500 1-800-613-4766

Fax: 828-622-3309

[email protected]

www.peerlessblowers.com


Recommended