+ All Categories
Home > Documents > Selenio 6800™ HDX6801+B2/C2 HDX 6801+B4/C4 … · 2010 DTS, Inc. All other trademarks ......

Selenio 6800™ HDX6801+B2/C2 HDX 6801+B4/C4 … · 2010 DTS, Inc. All other trademarks ......

Date post: 26-Aug-2018
Category:
Upload: buikhue
View: 218 times
Download: 0 times
Share this document with a friend
95
Delivering the Moment Installaon and Operaon Manual Selenio 6800™ HDX6801+B2/C2 & HDX- 6801+B4/C4 HD/SD Two- and Four-Channel AES Demulplexers Edion C 175-000260-00
Transcript

Delivering the Moment

Installation and Operation Manual

Selenio 6800™HDX6801+B2/C2 &HDX- 6801+B4/C4 HD/SDTwo- and Four-Channel AES Demultiplexers

Edition C

175-000260-00

Publication Information © 2014 Imagine Communications Corp. Proprietary and Confidential.

Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal.

This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.

Trademarks 6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D Series™, D Series DSX™, Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G Scribe™, HView™, IconMaster™, IconLogo™, IconSta-tion™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™, InstantOnline™, Invenio®, Live Update™, mCAPTURE™, Magellan™, Magellan CCS Navigator™, Magellan Q SEE™, MultiService SDN™, NetPlus™, NetVX™, NewsForce™, Nexio® G8™, Nexio AMP® ChannelView™, Nexio® Channel ONE™, Nexio® ClipSync™, Nexio® Delay™, Nexio® Digital Turnaround Processor™, Nexio® Farad™, Nexio® G Scribe™, Nexio® IconKey™, Nexio® IconLogo™, Nexio® IconMaster™, Nexio® IconStation™, Nexio® InfoCaster™, Nexio® InfoCaster Creator™, Nexio® InfoCaster Manag-er™, Nexio® InfoCaster Player™, Nexio® InfoCaster Traffic™, Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio® News-Force™, Nexio® NXIQ™, Nexio® Playlist™, Nexio® Remote™, Nexio®RTX Net™, Nexio® TitleMotion™, Nexio® TitleOne™, Nexio® Velocity ESX™, Nexio® Velocity PRX™, Nexio® Velocity XNG™, Nexio® Volt™, OPTO+™, Panacea™, Platinum™, Playlist™, Predator II GRF™, Predator II GX™, Punctuate™, Remote™, RTX Net™, QuiC™, Q SEE™, SD STAR™, Selenio™, Selenio 6800+™, SelenioNext™, Selenio X50™, Selenio X85™, Selenio X100™, TitleMotion™, TitleOne™, Velocity ESX™, Velocity PRX™, Velocity XNG™, Versio™, Videotek® SD STAR™, X50™, and X85™ are trademarks of Imagine Communica-tions or its subsidiaries.

Altitude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®, ICE Q® algorithms, ICE-PAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®, Nexio AMP®, PersonalizedTV®, Router-Works®, Videotek®, Videotek® ASI STAR®, Videotek® GEN STAR®, and Videotek® HD STAR® are registered trademarks of Imagine Communications or its subsidiaries.

Microsoft® and Windows® are registered trademarks of Microsoft Corporation. HD BNC is a trademark of Amphenol Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008 2010 DTS, Inc. All other trademarks and trade names are the property of their respective companies.

Contact Information Imagine Communications has office locations around the world. For locations and contact information see: http://www.imaginecommunications.com/contact us/

Support Contact Information For support contact information see:

▪ Support Contacts: http://www.imaginecommunications.com/services/technical support/ ▪ eCustomer Portal: http://support.imaginecommunications.com

© 2014 Imagine Communications Corp. Proprietary and Confidential

Edition CJanuary 2007

HDX6801+B2/C2 HDX6801+B4/C4HD/SD TV Two- and Four-Channel AES Demultiplexers

Installation and Operation Manual

Contents

PrefaceManual Information .............................................................................. vii

Purpose ........................................................................................... viiAudience ........................................................................................ viiRevision History ............................................................................ viiWriting Conventions ..................................................................... viiiObtaining Documents ................................................................... viii

Unpacking/Shipping Information .......................................................... ixUnpacking a Product ....................................................................... ixProduct Servicing ............................................................................ ixReturning a Product ........................................................................ ix

Restriction on Hazardous Substances (RoHS) Compliance ....................xWaste from Electrical and Electronic Equipment (WEEE) Compliance ............................................................................................ xiSafety .................................................................................................... xii

Safety Terms and Symbols in this Manual .................................... xii

Chapter 1: IntroductionOverview ..................................................................................................1Product Description ..................................................................................2

General Description ..........................................................................2Main Features ...................................................................................3

Module Descriptions ................................................................................4Front Module ....................................................................................4Back Connectors ...............................................................................6Signal Flow .....................................................................................10

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual iii

Contents

Chapter 2: InstallationOverview ............................................................................................... 11Maximum 6800+ Frame Power Ratings ............................................... 12Unpacking the Module .......................................................................... 13

Preparing the Product for Installation ............................................ 13Checking the Packing List ............................................................. 13

Setting Jumpers ..................................................................................... 14Installing and Removing HDX6801+ Modules .................................... 15Upgrading HDX6801+ Firmware ......................................................... 16

Correcting a Failed Upgrade Procedure ......................................... 20

Chapter 3: OperationOverview ............................................................................................... 21Operating Notes ..................................................................................... 22Audio Processing Information .............................................................. 23

Audio Output Channel Status ........................................................ 23Input Channel V-Bit Feedback (InxxVbitFb) ................................ 23Demux Group Control (Grp1-4 Ctrl) ............................................. 24Output Audio Rate ......................................................................... 24Audio De-embedding Channel Source Selection ........................... 24

Cross-Functional Parameter Changes ................................................... 25Parameter Availability Based on Operating Mode ............................... 27Changing Parameter Settings ................................................................ 28

Recalling Default Parameter Settings ............................................ 29Reading Software and Hardware Versions .................................... 29

Setting HDX6801+B2/C2 and HDX6801+B4/C4 Control Parameters 30LEDs and Alarms .................................................................................. 49

Monitoring LEDs ........................................................................... 49Module Status LEDs ...................................................................... 51Alarms ............................................................................................ 52

Chapter 4: SpecificationsOverview ............................................................................................... 55Inputs ..................................................................................................... 56

SDI Video Input ............................................................................. 56DARS Input .................................................................................... 56

Outputs .................................................................................................. 57AES Balanced Output (HDX6801+B2/B4 Only) .......................... 57

iv HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Contents

AES Unbalanced Output (HDX6801+C2/C4 Only) ......................57SDI Video Output (Reclocked) .......................................................58Propagation Delay ...........................................................................58

Power Consumption ...............................................................................59Operating Temperature ..........................................................................59

Appendix A: Communication and Control Troubleshooting Tips

Overview ................................................................................................61General Troubleshooting Steps ..............................................................62Software Communication and Control Issues ........................................63

+ Pilot Lite Fails to Communicate with Installed Modules ...........63+ Pilot Lite Does Not Find All Modules in Frame ........................65+ Pilot Lite or CCS Software Application Not Responding ..........65+ Pilot Lite Cannot Control a Module Showing in the Control Window ...................................................................65+ Pilot Lite Status Bar Reports “Not Ready” .................................66CCS Software Application or Remote Control Panel Does Not Communicate with Module ............................................................66Alarm Query Fails When a Device Reboots ...................................66

Hardware Communication and Control Issues ......................................67Frames Fail to Communicate with the PC after a Power Failure ...67Module Does Not Seem to Work ....................................................67

Contacting Customer Service .................................................................67

Appendix B: Audio Bit ManipulationOverview ................................................................................................69Manipulating Channel Status Bits (C-Bit) .............................................70Manipulating Validity and User Bits (V-Bit and U-Bit) ........................73Identifying Audio Characteristics (Audio Sampling Frequency and Word Length) ...................................................................................................74

IndexKeywords ...............................................................................................75

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual v

Contents

vi HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Preface

Manual Information

PurposeThis manual details the features, installation procedures, operational procedures, and specifications of the HDX6801+B2/C2 and HDX6801+B4/C4 HD and SD TV Two- and Four-Channel AES Demultiplexers.

AudienceThis manual is written for engineers, technicians, and operators responsible for the installation, setup, and/or operation of HDX6801+B2/C2 and HDX6801+B4/C4 HD and SD TV Two- and Four-Channel AES Demultiplexers.

Revision History

Table P-1. Document Revision History

Edition Date Revision HistoryA June 2005 Initial release

B April 2006 Addition of support for SMPTE 296M, firmware upgrade tool, and index

C January 2007 Re-branding

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual vii

Preface

Writing ConventionsTo enhance your understanding, the authors of this manual have adhered to the following text conventions:

Obtaining DocumentsProduct support documents can be viewed or downloaded from our Web site. Alternatively, contact your Customer Service representative to request a document.

Table P-2. Writing Conventions

Term or Convention Description

Bold Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names.

Italics Indicates email addresses, the names of books or publications, and the first instances of new terms and specialized words that need emphasis.

CAPS Indicates a specific key on the keyboard, such as ENTER, TAB, CTRL, ALT, or DELETE.

Code Indicates variables or command-line entries, such as a DOS entry or something you type into a field.

> Indicates the direction of navigation through a hierarchy of menus and windows.

hyperlink Indicates a jump to another location within the electronic document or elsewhere

Internet address

Indicates a jump to a Web site or URL

NoteIndicates important information that helps to avoid and troubleshoot problems.

viii HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Preface

Unpacking/Shipping InformationUnpacking a Product

This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble-free service. 1. Check equipment for any visible damage that may have occurred

during transit. 2. Confirm that you have received all items listed on the packing list. 3. Contact your dealer if any item on the packing list is missing.4. Contact the carrier if any item is damaged.5. Remove all packaging material from the product and its associated

components before you install the unit.Keep at least one set of original packaging, in the event that you need to return a product for servicing.

Product ServicingExcept for firmware upgrades, HDX6801+B2/C2 and HDX6801+B4/C4 modules are not designed for field servicing. All hardware upgrades, modifications, or repairs require you to return the modules to the Customer Service center.

Returning a ProductIn the unlikely event that your product fails to operate properly, please contact Customer Service to obtain a Return Authorization (RA) number, then send the unit back for servicing. Keep at least one set of original packaging in the event that a product needs to be returned for service. If the original package is not available, you can supply your own packaging as long as it meets the following criteria:• The packaging must be able to withstand the product’s weight.• The product must be held rigid within the packaging.• There must be at least 2 in. (5 cm) of space between the product and

the container.• The corners of the product must be protected.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual ix

Preface

Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the product is still within the warranty period, we will return the product prepaid after servicing.

Restriction on Hazardous Substances (RoHS) Compliance

Directive 2002/95/EC—commonly known as the European Union (EU) Restriction on Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling. The Directive, which took effect on July 1, 2006, refers to the following hazardous substances: • Lead (Pb)• Mercury (Hg)• Cadmium (Cd)• Hexavalent Chromium (Cr-V1)• Polybrominated Biphenyls (PBB)• Polybrominated Diphenyl Ethers (PBDE)According to this EU Directive, all products sold in the European Union will be fully RoHS-compliant and “lead-free.” (See our Web site, www.broadcast.harris.com/leitch, for more information on dates and deadlines for compliance.) Spare parts supplied for the repair and upgrade of equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies with the EU directive will be marked with a RoHS-compliant emblem, as shown in Figure P-1.

Figure P-1. RoHS Compliance Emblem

x HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Preface

Waste from Electrical and Electronic Equipment (WEEE) Compliance

The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products. As of August 13, 2005, producers or users will be required to recycle electrical and electronic equipment at end of its useful life, and may not dispose of the equipment in landfills or by using other unapproved methods. (Some EU member states may have different deadlines.)In accordance with this EU Directive, companies selling electric or electronic devices in the EU will affix labels indicating that such products must be properly recycled. (See our Web site, www.broadcast.harris.com/leitch, for more information on dates and deadlines for compliance.) Contact your local sales representative for information on returning these products for recycling. Equipment that complies with the EU directive will be marked with a WEEE-compliant emblem, as shown in Figure P-2.

Figure P-2. WEEE Compliance Emblem

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual xi

Preface

SafetyCarefully review all safety precautions to avoid injury and prevent damage to this product or any products connected to it. If this product is rack-mountable, it should be mounted in an appropriate rack using the rack-mounting positions and rear support guides provided. It is recommended that each frame be connected to a separate electrical circuit for protection against circuit overloading. If this product relies on forced air cooling, it is recommended that all obstructions to the air flow be removed prior to mounting the frame in the rack. If this product has a provision for external earth grounding, it is recommended that the frame be grounded to earth via the protective earth ground on the rear panel.IMPORTANT! Only qualified personnel should perform service procedures.

Safety Terms and Symbols in this ManualWARNINGStatements identifying conditions or practices that may result in personal injury or loss of life. High voltage is present.

CAUTIONStatements identifying conditions or practices that can result in damage to the equipment or other property.

xii HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 1

Introduction

OverviewThe HDX6801+B2/C2 and HDX6801+B4/C4 are two- and four-channel high-definition audio demultiplexers, respectively. The HDX6801+B2 and HDX6801+C2 modules can de-embed two AES audio signals from a provided HD or SD video signal, while the HDX6801+B4 and HDX6801+C4 can de-embed four AES audio signals.HDX6801+B2/B4 module versions provide balanced AES outputs, while HDX6801+C2/C4 module versions provide unbalanced AES outputs.

The following topics are described in this chapter:• “Product Description” on page 2• “Main Features” on page 3• “Module Descriptions” on page 4• “Signal Flow” on page 10

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 1

Chapter 1: Introduction

Product Description

General DescriptionThe HDX6801+B2/C2 and HDX6801+B4/C4 HD and SD TV Two and Four Channel AES Demultiplexers can (respectively) de-embed two and four AES audio signals from a single 1.5 Gb/s HD or 270 Mb/s SD video signal in both balanced (B2 and B4) and unbalanced (C2 and C4) formats.Following SMPTE 299M and 259M-C specifications, these demultiplexers are able to de-embed to up to four AES audio signals from SDI inputs; an included DARS input provides AES-11 compliance. These modules can either be controlled locally (via card edge) or controlled and monitored remotely (with software applications such as +Pilot Lite™, CCS™ Pilot™, and CCS Navigator™, or CCS-compliant remote control panels, such as NUCLEUS™ Network Control Panel and other products).Four module types are available:• HDX6801+B2 has one unbalanced DARS input, one balanced

DARS input, one SDI video input, four SDI reclocked outputs, and two balanced AES output channels.

• HDX6801+B4 has one unbalanced DARS input, one balanced DARS input, one SDI video input, four SDI reclocked outputs, and four balanced AES output channels.

• HDX6801+C2 has one unbalanced DARS input, one SDI video input, four SDI reclocked outputs, and two unbalanced AES output channels.

• HDX6801+C4 has one unbalanced DARS input, one SDI video input, four SDI reclocked outputs, and four unbalanced AES output channels.

The back connectors for both module types require two frame slots within an FR6802+QXF or FR6802+XF frame (there is no backward-compatibility provided for use with 6800/7000 series frames).

2 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 1: Introduction

Main FeaturesOther HDX6801+B2/C2 and HDX6801+B4/C4 features include the following:• Inputs:

• One SMPTE 292M HD-SDI or SMPTE 259M-C SD-SDI input• One unbalanced DARS AES reference input• One balanced DARS AES reference input (HDX6801+B2/B4

versions only)• Outputs:

• Four SMPTE 292M HD-SDI or SMPTE 259M-C SD-SDI reclocked outputs

• Two AES digital audio outputs (HDX6801+B2/C2 versions)• Four AES digital audio outputs (HDX6801+B4/C4 versions)

• Automatic detection of all SMPTE 292M HD-SDI and SMPTE 259M-C SD-SDI video standards

• Auto-detection of input video standard, or user-selection of standard

• 24-bit AES audio de-embedding• Audio processing amplification with controls for delay, gain, invert,

channel multiplexing and dithering• 16-bit, 20-bit, or 24-bit audio processing (selectable word length in

channel pairs)• Audio test tone generating• Programmable audio delays (up to 1.3 sec)• Card-edge LEDs to indicate audio and video signal presence and

module failure• Serial and Ethernet remote control and monitoring• Compliance with AES11• Support for SMPTE 296M (50, 59.94 and 60 Hz frame rates)

HD-SDI

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 3

Chapter 1: Introduction

Module Descriptions

Front ModuleFigure 1-1 is a generic top-front view of a typical 6800+ module and shows the general location of standard LEDs, controls, and jumpers. The number of Control and Monitoring LEDs on 6800+ modules varies.

Figure 1-1. Typical 6800+ Module

Table 1-1 on page 5 briefly describes generic 6800+ LEDs, switches, and jumpers. See “Chapter 3: Operation” for more information on specific HDX6801+B2/C2 and HDX6801+B4/C4 module controls, LEDs, and jumpers.

Module status LEDs

Mode select rotary switch

Navigation toggle switch

Monitoring LEDs

Remote/local control jumper

Extractor handle

Control LEDs

4 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 1: Introduction

Table 1-1. Generic 6800+ Module Features

Feature DescriptionModule status LEDs

Various color and lighting combinations of these LEDs indicate the module state. See “Monitoring LEDs” on page 49 for more information.

Mode select rotary switch

This switch selects between various control and feedback parameters.

Navigation toggle switch

This switch navigates up and down through the available control parameters:• Down: Moves down through the parameters• Up: Moves up through the parameters

Control LEDs Various lighting combinations of these Control LEDs (sometimes referred to as “Bank Select LEDs”) indicate the currently selected bank. See Table 3-6 “Selected Bank as Indicated by Control LEDs” for more information.

Monitoring LEDs

Each 6800+ module has a number of LEDs assigned to indicate varying states/functions. See “Monitoring LEDs” on page 49 for a description of these LEDs.

Local/remote control jumper

• Local: Locks out external control panels and allows card-edge control only; limits the functionality of remote software applications to alarm monitoring

• Remote: Allows remote or local (card-edge) configuration, operation, and monitoring of the HDX6801+B2/C2 and HDX6801+B4/C4

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 5

Chapter 1: Introduction

Back ConnectorsHDX6801+B2

Figure 1-2 shows the double-slot back connector used by the HDX6801+B2 module when installed in an FR6802+XF frame.

Figure 1-2. HDX6801+B2 Back Connector

SDI IN

1

2

3

4

DARS IN

DARS IN BAL

AESOUT SDI

RECLK

+

+

+

+

+

1

2

Unbalanced DARSinput

Balanced DARSinput

Balanced AESoutputs

SDI video input

SDI reclocked outputs

Reserved forfuture use

AES OUT

6 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 1: Introduction

HDX6801+B4Figure 1-3 shows the double-slot back connector used by the HDX6801+B4 module when installed in an FR6802+XF frame.

Figure 1-3. HDX6801+B4 Back Connector

SDI IN

1

2

DARS IN

DARS IN BAL

3

4

+

+

+

1

2

3

4

AESOUT

+

+

SDIRECLK

Unbalanced DARSinput

Balanced DARSinput

Balanced AESoutputs

SDI video input

SDI reclocked outputs

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 7

Chapter 1: Introduction

HDX6801+C2Figure 1-4 shows the double-slot back connector used by the HDX6801+C2 module when installed in an FR6802+XF frame.

Figure 1-4. HDX6801+C2 Back Connector

SDI IN

1

2

3

4

DARS IN

1

2

AESOUT

SDIRECLK

Unbalanced DARSinput

Unbalanced AESoutputs

SDI video input

SDI reclocked outputs

Reserved forfuture use

8 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 1: Introduction

HDX6801+C4Figure 1-5 shows the double-slot back connector used by the HDX6801+C4 module when installed in an FR6802+XF frame.

Figure 1-5. HDX6801+C4 Back Connector

SDI IN

DARS IN

AESOUT

SDIRECLK

1

2

3

4

1

2

3

4

Unbalanced DARSinput

Unbalanced AESoutputs

SDI video input

SDI reclocked outputs

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 9

Chapter 1: Introduction

Signal FlowFigure 1-6 shows the basic signal flow of the HDX6801+B2/C2 and HDX6801+B4/C4 modules.

Figure 1-6. HDX6801+ Series Signal Flow Diagram

Equalizer Deserializerinput/output

De-embedder

Driver 1

Driver 2SDI input

ReclockedSDI outputs

AES

1

AES

2

AES

3

AES

4Audio processing

amplifierAESoutputs

B4/C4 options

DARSinput

CCS control/monitor port

10 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 2

Installation

OverviewThis chapter describes the HDX6801+B2/C2 and HDX6801+B4/C4 installation process, including the following topics:• “Maximum 6800+ Frame Power Ratings” on page 12• “Unpacking the Module” on page 13• “Setting Jumpers” on page 14• “Installing and Removing HDX6801+ Modules” on page 15• “Upgrading HDX6801+ Firmware” on page 16

See the FR6802+ Frame Installation and Operation Manual for information about installing and operating FR6802+ series frames and their components.

CautionBefore installing this product, read the 6800+ Series Safety Instructions and Standards Manual shipped with every FR6802+ Frame Installation and Operation Manual or downloadable from our Web site. This safety manual contains important information about the safe installation and operation of 6800+ series products.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 11

Chapter 2: Installation

Maximum 6800+ Frame Power RatingsThe power consumption for HDX6801+B2/C2 and HDX6801+B4/C4 modules is 7 W from the positive supply and 0.3 W from the negative supply. Power consumption information is also listed in “Chapter 4: Specifications”.Table 2-1 states the maximum allowable power ratings for 6800+ frames. Note the given maximums before installing any 6800+ modules in your frame. HDX6801+ modules cannot be installed in frames without fans, or in FR6802+DM and 6800/7000 series frames.

Table 2-1. Maximum Power Settings for 6800+ Frames

6800+ Frame TypeMax. Frame Power Dissipation

Max. number of Installed HMX6801+ Modules

Max Power Dissipation for Two Slots

FR6802+QXF(frame with AC or DC power supply)

120 W 10 12 W

FR6802+XF(frame with AC power supply)

120 W 10 12 W

FR6802+XF(frame with DC power supply)

120 W 10 10.5 W

12 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 2: Installation

Unpacking the Module

Preparing the Product for InstallationBefore you install the HDX6801+B2/C2 and HDX6801+B4/C4, perform the following:• Check the equipment for any visible damage that may have

occurred during transit.• Confirm receipt of all items on the packing list. See “Checking the

Packing List” for more information.• Remove the anti-static shipping pouch, if present, and all other

packaging material.• Retain the original packaging materials for possible re-use.

See “Unpacking/Shipping Information” on page ix for information about returning a product for servicing.

Checking the Packing List

NoteContact your product Customer Service representative if parts are missing or damaged.

Table 2-2. Available Product Packages

Ordered Product Content DescriptionHDX6801+B2D, HDX6801+B4D, HDX6801+C2D, or HDX6801+C4D

• One front module• One back connector• One HDX6801+B2/C2 and

HDX6801+B4/C4 HD/SD TV Two and Four Channel AES Demultiplexers Installation and Operation Manual

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 13

Chapter 2: Installation

Setting JumpersThe HDX6801+B2/C2 and HDX6801+B4/C4 modules have one standard jumper for remote or local control. Figure 2-1 shows the location of the REM/LOC jumper.

Figure 2-1. Location of the REM/LOC Jumper

Follow this procedure to set the REM/LOC jumper for either remote or local control:1. Locate the REM/LOC control jumper on the module (beside the

extractor handle).Figure 2-1 shows the standard location of the REM/LOC jumper.

2. Place a jumper on pins 1 and 2 to set the module for Remote control or pins 2 and 3 to set the module for Local control. See Figure 2-2.

Figure 2-2. REM/LOC Settings for Remote and Local Control

See Table 1-1 on page 5 for more information on local/remote control jumper functionality.

REM/LOC jumperRemote/local

NoteYou need to configure modules for local or remote operation prior to power-up. To change the configuration, first remove power from the module, reset the jumper, and then reapply power.

The white triangle near the jumper pins on the module indicates pin 1.

1 2 3 1 2 3

Remote control setting Local control setting

14 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 2: Installation

Installing and Removing HDX6801+ ModulesThe HDX6801+ modules have double-width back connectors. The modules cannot be installed in frames without fans, or in FR6802+DM and 6800/7000 series frames.These modules require no specialized installation or removal procedures. However, if you are installing both front and rear modules, ensure that the back module is installed first before plugging in the front module. Likewise, ensure that the front module is unplugged from the frame before removing the rear module. See the FR6802+ Frames Installation and Operation Manual for information about installing and operating an FR6802+ frame and its components.

CautionBefore installing your modules, see Table 2-1 "Maximum Power Settings for 6800+ Frames" on page 12.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 15

Chapter 2: Installation

Upgrading HDX6801+ FirmwareFirmware upgrading is a routine procedure that you must perform to install newer versions of software on a HDX6801+ module. The HDX6801+ module can be upgraded in Boot Loader mode only. CCS Pilot, Co-Pilot, or Navigator software version 3.1.1 or later is required for this procedure. The HDX6801+ must be installed in a frame that contains or is connected to another frame that contains an ICE6800+ module. When performing the upgrading procedure, check the appropriate readme file to confirm which files are needed. Use care to ensure that you upload the correct files to the HDX6801+ module. If for some reason the upgrade fails, the module may not respond to controls and will appear to be non-functional. In that event, follow the procedures described in “Correcting a Failed Upgrade Procedure” on page 20. Follow these steps to upgrade a HDX6801+ module’s firmware:1. Download the most recent appropriate upgrade package from the

our Web site or from your CD-ROM.2. Remove the HDX6801+ module from the 6800+ frame.3. Set the hex switch to F.

Figure 2-3. Buttons on a Typical Card Edge

4. While pressing the Navigation toggle switch down, reinsert the HDX6801+ module into the frame and then release the Navigation toggle switch.

Mode select rotary (hex) switch

Navigation toggle switch

16 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 2: Installation

5. Perform a Discovery operation to discover the HDX6801+ module, as described in your CCS software application manual or online help. (If you cannot discover the HDX6801+ module using the Discovery tool, see “Discovering Devices Using the Drag-and-Drop Method” on page 19.)

6. From the Tools menu, select Software Upgrade. The Software Upgrade window opens or is brought to the foreground.

Figure 2-4. Typical Software Upgrade Tool New Transfer Tab

7. On the New Transfer tab, click Add.The Device Selection dialog opens.

8. Select one or more HDX6801+ devices, and then click OK to close the Add Device dialog box. When adding modules to the list, keep in mind the following points: • You can only add one module per IP address. All modules in up

to nine frames that are connected to the same ICE6800+ module have the same IP address.

Click Device Options to enter Telnet and FTP user name and password or create automatic backups.

Click Package Info to view a list of the components contained in the ZIP file.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 17

Chapter 2: Installation

• You can only upgrade one device type: e.g., you can add a series of HDX6801+ modules that all reside at different IP addresses.

The selected devices appear in the table on the New Transfer tab of the Software Upgrade window. This table lists devices that are to receive the upgrade package.You can click on an individual item in the list to view module-specific information: • To highlight the position of a module in the Navigation

window, click Find Device. • To check the module’s software revision numbers, etc., click

Version Info. • To create an automatic backup of the selected module’s

firmware, click Device Options.... (Place a check beside Software Backup and enter a file name or click Browse to choose a new file location.)

9. Press Browse... to select the software upgrade package (ZIP file). A standard Windows File Selection dialog opens.

10. Choose the upgrade ZIP file on a local or network drive. The selected file’s path name is displayed in the edit box to the left of the Browse… button.The extraction process on the ZIP file is handled as part of the upgrade process. You do not need to extract the files yourself.

11. Press Submit Transfer... A dialog box opens, requesting confirmation that you want to proceed with the request. If you have multiple devices selected, multiple transfer tasks are submitted—one per device.The transfer now progresses. You may close the Software Upgrade window, continue with other tasks, or switch to the Progress tab to view the status of the transfers.

12. Click on the Log tab and look at the Progress column to ensure that all files have correctly updated.

13. When the update is complete, reboot the HDX6801+ module by manually pulling it out and then pushing it back into its slot in the frame. You cannot click Reboot Device to reboot HDX6801+ modules.

NoteClosing the Software Upgrade window does not effect any transfer processes that may be running in the background. However, if you try to log off or exit the CCS software while a transfer is underway, a notification window will alert you that processes are still active and will ask if you want to terminate these processes.

18 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 2: Installation

Your upgrade procedure is complete. If for some reason the upgrade fails, the module may not respond to controls and will appear to be non-functional. In that event, follow the procedures described in “Correcting a Failed Upgrade Procedure” on page 20.

Discovering Devices Using the Drag-and-Drop MethodIf you cannot discover your HDX6801+ module using the Discovery tool, use this method to discover it:1. With your CCS software in Build mode, drag or copy and paste the

module’s device icon from the Catalog folder into the Network or Discovery folder.

2. Right-click the device icon and then select Properties. 3. On the Device tab of the Navigation Properties box, enter the IP

address of the frame that holds the module.

Figure 2-5. Navigation Properties Box

4. In the third field, enter the slot number of the HDX6801+ module, and then close the window.

You can now continue upgrading your HDX6801+ module’s firmware, starting with step 3 in “Upgrading HDX6801+ Firmware” on page 16.

CautionDo not make changes in the last field (located above and to the right of the Set Default button.)

Do not make changes in this field

Enter frame IP number here

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 19

Chapter 2: Installation

Correcting a Failed Upgrade ProcedureFirmware upgrades may fail in the event of network interruptions, power failures, or if files were sent to the wrong 6800+ module.These problems can be corrected by re-installing the firmware while in Boot Loader mode, as described below. When you are performing this procedure, check the appropriate readme file to confirm which files are needed. Use care to ensure that you upload the correct files to the HDX6801+ module.Follow these steps to upgrade the firmware in Boot Loader mode: 1. Download the most recent appropriate upgrade package from the

our Web site or from your CD-ROM, and then unzip the upgrade package.

2. If the HDX6801+ module has not been discovered by your CCS software application, enter Build mode, and then discover your module using the drag-and-drop method. See “Discovering Devices Using the Drag-and-Drop Method” on page 19 for more information.

3. Double-click the device icon for the HDX6801+ module. The Configuration... box opens. On the File Transfer tab, the /frameX/slotY (where X is the frame number and Y is the slot number) directory appears in the Select the device directory to transfer to: field.

4. Click Add, and in the Add Upgrade Files box, browse, select the HDX6801+ module’s upgrade package and then click OK.

5. On the File Transfer tab, choose the file you wish to upgrade and then click OK.

6. Click Perform Transfer and then click Yes.This may take several minutes.

7. When the message File transfer to device succeeded appears in the status bar, reboot the HDX6801+ module by manually pulling it out and then pushing it back into its slot in the frame. You cannot click Reboot Device to reboot HDX6801+ modules.

Your upgrade procedure is complete.

NoteTo successfully upgrade the firmware, you must follow these steps in the exact sequence described.

NoteYou must delete unwanted files in the Add upgrade files for transfer to device: field before transferring the files. Otherwise, the upgrading procedure will fail.

20 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3

Operation

OverviewThis chapter describes how to operate the HDX6801+B2/C2 and HDX6801+B4/C4 using card-edge controls only. See the following product documents for information on how to operate this product remotely:• + Pilot Lite User Manual for serial control interface• CCS Pilot, CoPilot, Navigator, or NUCLEUS Network Control

Panel, RCP-CCS-1U Remote Control Panel manual for Ethernet control interface

The following topics are discussed in this chapter:• “Operating Notes” on page 22• “Audio Processing Information” on page 23• “Cross-Functional Parameter Changes” on page 25• “Changing Parameter Settings” on page 28• “Setting HDX6801+B2/C2 and HDX6801+B4/C4 Control

Parameters” on page 30• “LEDs and Alarms” on page 49

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 21

Chapter 3: Operation

Operating NotesWhen setting the control parameters on the HDX6801+B2/C2 and HDX6801+B4/C4, observe the following:• If you make changes to certain parameters, other related parameters

may also be affected. See the section “Setting HDX6801+B2/C2 and HDX6801+B4/C4 Control Parameters” on page 30 for more information.

• When you change a parameter, the effect is immediate. However, the module requires up to 20 seconds to save the latest change. After 20 seconds, the new settings are saved and will be restored if the module loses power and must be restarted.

• When you set the Factory Recall parameter to Yes, the module takes several seconds to reset all of the parameters to their default settings.

• Terminate any unused coaxial output connectors with a 75Ω terminator.

See the following topics for more operational information:• “Audio Output Channel Status” on page 23• “Input Channel V-Bit Feedback (InxxVbitFb)” on page 23• “Demux Group Control (Grp1-4 Ctrl)” on page 24• “Output Audio Rate” on page 24• “Audio De-embedding Channel Source Selection” on page 24

22 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Audio Processing Information

Audio Output Channel StatusTable 3-1 describes the audio output channel status.

Input Channel V-Bit Feedback (InxxVbitFb)Table 3-2 describes the input channel V-bit (Validity-bit) feedback.

Table 3-1. Audio Output Channel Status Description

Item DescriptionPeak The audio output level has reached a level

of 0 dBFS.

Silence The audio output level is lower than -96 dBFS.

Normal The audio output level is between the Peak and Silence threshold levels.

Table 3-2. Input Channel V-Bit (Validity-bit) Feedback Description

Item DescriptionOn The V-bit of the incoming audio channel is

set to 1. This can indicate that the audio sample word data is invalid (or possibly compressed audio) and is not suitable for D/A conversion.

Off The V-bit of the incoming audio channel is set to 0. This can indicate that the audio sample word data is valid and is suitable for D/A conversion.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 23

Chapter 3: Operation

Demux Group Control (Grp1-4 Ctrl)Table 3-3 describes the demux group control.

Output Audio RateThe output audio rate of the HDX6801+B2/C2 and HDX6801+B4/C4 modules are always 48 kHz. De-embedding audio that was embedded at a rate other than 48 kHz is not supported. The HDX6801+B2/C2 and HDX6801+B4/C4 modules will report the embedded audio group sampling rates, as indicated by the “Rate” word of the audio control packet, in the G1SmplRate, G2SmplRate, G3SmplRate and G4SmplRate parameters.

Audio De-embedding Channel Source SelectionOn the HDX6801+B2/C2 and HDX6801+B4/C4 modules, the following audio source selections are available for each OutxxSrc parameter:• Ch01 to Ch 16• Test Tone 1 (750 Hz, -20 dBFS)• Test Tone 2 (1.5 kHz, -20 dBFS)• Test Tone 3 (3 kHz, -20 dBFS)• Test Tone 4 (6 kHz, -20 dBFS)

Table 3-3. Demux Group Control Description

Item Description

Repeat Upon detection of a de-embedding error, the de-embedder will repeat the last good AES sample.

Mute Upon detection of a de-embedding error, the de-embedder will mute the current outgoing AES sample.

24 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Cross-Functional Parameter ChangesWhen you configure certain parameters, you force a change in other associated parameters. The following table describes those parameters affected by other option selections.

Table 3-4. Cross-Functional Parameter Changes

Condition Forced Setting Enabled/Disabled Parameters

Output Ch1A Format=Non-PCM or Output Ch1A Format=Auto and Out Ch1A Format Fb=Non-PCM

• Output Ch1A Gain=0 dB• Output Ch1A Invert=No

• Output Ch1A Gain=Disabled• Output Ch1A Invert=Disabled

Output Ch1A Format= PCMorOutput Ch1A Format=Auto and Out Ch1A Format Fb= PCM

• Output Ch1A Gain=Enabled• Output Ch1A Invert=Enabled

Output Ch1B Format=Non-PCM or Output Ch1B Format=Auto and Out Ch1B Format Fb=Non-PCM

• Output Ch1B Gain=0 dB• Output Ch1B Invert=No

• Output Ch1B Gain=Disabled• Output Ch1B Invert=Disabled

Output Ch1B Format= PCMorOutput Ch1B Format=Auto and Out Ch1B Format Fb=PCM

• Output Ch1B Gain=Enabled• Output Ch1B Invert=Enabled

Output Ch2A Format=Non-PCM or Output Ch2A Format=Auto and Out Ch2A Format Fb=Non-PCM

• Output Ch2AB Gain=0 dB• Output Ch2A Invert=No

• Output Ch2AB Gain=Disabled• Output Ch2A Invert=Disabled

Output Ch2A Format= PCMorOutput Ch2A Format =Auto and Out Ch2A Format Fb=PCM

• Output Ch2AB Gain=Enabled• Output Ch2A Invert= Enabled

Output Ch2B Format=Non-PCM or Output Ch2B Format=Auto and Out Ch2B Format Fb= Non-PCM

• Output Ch2B Gain=0 dB• Output Ch2B Invert=No

• Output Ch2B Gain= Disabled• Output Ch2B Invert=Disabled

Output Ch2B Format=PCMorOutput Ch2B Format=Auto and Out Ch2B Format Fb= PCM

• Output Ch2B Gain=Enabled• Output Ch2B Invert=Enabled

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 25

Chapter 3: Operation

1Output Ch3A Format=Non-PCM or Output Ch3A Format=Auto and Out Ch3A Format Fb=Non-PCM

• Output Ch3A Gain=0 dB• Output Ch3A Invert=No

• Output Ch3A Gain= Disabled• Output Ch3A Invert=Disabled

1Output Ch3A Format=PCMorOutput Ch3A Format=Auto and Out Ch3A Format Fb=PCM

• Output Ch3A Gain=Enabled• Output Ch3A Invert=Enabled

1Output Ch3B Format=Non-PCM or Output Ch3B Format=Auto and Out Ch3B Format Fb=Non-PCM

• Output Ch3B Gain=0 dB• Output Ch3B Invert=No

• Output Ch3B Gain=Disabled• Output Ch3B Invert=Disabled

1Output Ch3B Format=PCMorOutput Ch3B Format=Auto and Out Ch3B Format Fb=PCM

• Output Ch3B Gain= Enabled• Output Ch3B Invert=Enabled

1Output Ch4A Format=Non-PCMor Output Ch4A Format=Auto and Out Ch4A Format Fb=Non-PCM

• Output Ch4A Gain=0 dB• Output Ch4A Invert=No

• Output Ch4A Gain=Disabled• Output Ch4A Invert=Disabled

1Output Ch4A Format= PCMorOutput Ch4A Format=Auto and Out Ch4A Format Fb=PCM

• Output Ch4A Gain=Enabled• Output Ch4A Invert=Enabled

1Output Ch4B Format=Non-PCM or Output Ch4B Format=Auto and Out Ch4B Format Fb=Non-PCM

• Output Ch4B Gain=0 dB• Output Ch4B Invert=No

• Output Ch4B Gain=Disabled• Output Ch4B Invert=Disabled

1Output Ch4B Format=PCMorOutput Ch4A Format=Auto and Out Ch4B Format Fb=PCM

• Output Ch4B Gain=Enabled• Output Ch4B Invert= Enabled

1 Conditions for parameters related to output channels 3A, 3B, 4A, and 4B apply only toHDX6801+B4 and HDX6801+C4 module versions.

Table 3-4. Cross-Functional Parameter Changes (Continued)

Condition Forced Setting Enabled/Disabled Parameters

26 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Parameter Availability Based on Operating Mode

Depending on whether the operating mode is HD or SD, some parameters will be enabled and some disabled. The HD parameters will apply when SdiStdSet is set to one of the HD operating modes, or when the SdiStdSet is set to Auto and SdiStdFdbk is one of the HD operating modes. The SD parameters will apply when SdiStdSet is set to either SD 525 or SD 625, or the SDISTDSET is set to Auto and SdiStdFdbk is SD 525 or SD 625.

Table 3-5.

Condition Enabled Parameters

Disabled Parameters

HD Operating Mode: • 1035i/30• 1035i/29.97• 1080i/25 (295M)• 1080i/30• 1080i/29.97• 1080i/25• 1080p/30• 1080p/29.97• 1080p/25• 1080p/24• 1080p/23.98• 720p/60• 720p/59.94• 720p/50

• YCrcErrCnt• YCrcErrClr• CCrcErrCnt• CCrcErrClr• Grp1-4ActCh• G1-4SmplRate• Grp1-4Dly1_2• Grp1-4Dly3_4• Erp1-4ECCErr

• EdhPrsnt• EdhErrCnt• EdhErrClr

SDI Operating Mode:• SD 525• SD 625

• EdhPrsnt• EdhErrCnt• EdhErrClr

• YCrcErrCnt• YCrcErrClr• CCrcErrCnt• CCrcErrClr• Grp1-4ActCh• G1-4SmplRate• Grp1-4Dly1_2• Grp1-4Dly3_4• Erp1-4ECCErr

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 27

Chapter 3: Operation

Changing Parameter SettingsFollow these steps to change the HDX6801+B2/C2 and HDX6801+B4/C4 parameter settings:1. Rotate the mode select rotary switch (hex switch) to “0.”2. Once the hex switch is set to “0,” toggle the navigation switch up or

down to select a bank. View the two control LEDs next to the navigation toggle switch to see which bank is currently selected.

See Table 3-7 on page 31 to view the various banks, hex switch positions, and corresponding parameter options and values.

3. Rotate the hex switch to the parameter number (1 to 9) or letter (A to F) of the option you want to set.

4. Toggle the navigation switch to select and set the value of the chosen parameter.

5. Rotate the hex switch to another parameter number/letter in the current bank, and then repeat step 4.orRotate the hex switch to “0” again to select a different bank, and then repeat steps 3 and 4.

Table 3-6. Selected Bank as Indicated by Control LEDs

Bank Select LED 1(first top LED)

Bank Select LED 2(second top LED)

Bank Select LED 3(third top LED) Bank Number

Off Off Off 0

On Off Off 1

Off On Off 2

On On Off 3

Off Off On 4

On Off On 5

Off On On 6

On On On 7

NoteThe manufacturer recommends that you use the available 6800+ software control options (serial/local or Ethernet/remote) to aid in viewing, setting, and confirming parameter values.

28 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Recalling Default Parameter SettingsTable 3-7 on page 31 describes all of the parameter settings for the HDX6801+B2/C2 and HDX6801+B4/C4 modules, including the original factory defaults. To return this module to its default settings, you can either reset each parameter individually or do a global recall following this procedure:1. Rotate the hex switch to “0.”2. Toggle the navigation switch to the bank number “0.”

Use the control LEDs to verify which bank you have selected, or use an available 6800+ software control option (serial/local or Ethernet/remote) to aid in confirming your bank selection.

3. Rotate the hex switch to the global recall parameter “F.”4. Toggle the navigation switch to “On.”

Use an available 6800+ software control option to aid in viewing, setting, and confirming the parameter value.

Reading Software and Hardware VersionsThe current software version of your HDX6801+B2/C2 and HDX6801+B4/C4 modules can only be viewed using a CCS-enabled control panel or a CCS software application, such as Pilot or +Pilot Lite. See your control panel installation and operation manual, CCS software application user manual, or CCS software application online help for information on viewing software and hardware version numbers.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 29

Chapter 3: Operation

Setting HDX6801+B2/C2 and HDX6801+B4/C4 Control Parameters

Table 3-7 lists all of the available parameters and options for the HDX6801+B2/C2 and HDX6801+B4/C4. All parameters clip unless otherwise indicated.The On/Off combinations of the control LEDs on the card-edge indicate the active bank number. See “Changing Parameter Settings” on page 28 for more information.

LegendBold option = Indicates that this is the default setting for the parameter[RO] = Indicates that parameters are read-only/feedback, and cannot be used to select controls1(superscript digit)= Indicates that there is a footnote for this parameter entry, found at the end of the table* = Indicates that this parameter is only available on HDX6801+B2 and HDX6801+B4 module versions** = Indicates that this parameter is only available on HDX6801+B4 and HDX6801+C4 module versions

NoteThe sequence of options listed in the Options column mirrors the sequence achieved when you move the Navigation Toggle switch up.

30 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Table 3-7. Parameter Options Bank, Rotary Switch

Parameter Name Function Options

Bank 0

0, 1 SDI IP Video Std Set Selects the SDI input video signal standard • Auto• SD 525• SD 625• 1035I30• 1035I29.97• 1080I25 (295M)• 1080I30• 1080I29.97• 1080I25• 1080P30• 1080P29.97• 1080P25• 1080P24• 1080P23.98• 720P60• 720P59.94• 720P50

0, 2 Y CRC Err Cnt Clear Clears the luminance CRC error counter • No• Yes

0, 3 C CRC Err Cnt Clear Clears the chrominance CRC error counter • No• Yes

0, 4 DARS Input Type* Selects the type of DARS input (balanced/unbalanced)

• Balanced• Unbalanced

0, 5 Demux Group1 Control

Controls the audio option when demuxed group 1 is present with an error

• Mute• Repeat

0, 6 Demux Group2 Control

Controls the audio option when demuxed group 2 is present with an error

• Mute• Repeat

0, 7 Demux Group3 Control

Controls the audio option when demuxed group 3 is present with an error

• Mute• Repeat

0, 8 Demux Group4 Control

Controls the audio option when demuxed group 4 is present with an error

• Mute• Repeat

0, 9 DBN Control Controls handling of DBN (Data Block Number) error reporting

• Alert• Ignore

0, A to 0, E Input Ch01 to Ch05 Delay

Adjusts delay for de-embedded channels 01 to 05, respectively

0.0 to 1320.0 msec

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 31

Chapter 3: Operation

0, F Factory Recall Recalls the factory settings • Off• On

Bank 1

1, 1 to 1, B Input Ch06 to Ch16 Delay

Adjusts delay for de-embedded channels 06 to 16, respectively

0.0 to 1320.0 msec

1, C V-Bit Mute Enable Enables audio channel muting upon detection of an incoming set V-bit

• No• Yes

1, D Out 1A Source Select Selects the source for AES output 1A • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

32 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

1, E Out 1B Source Select Selects the source for AES output 1B • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 33

Chapter 3: Operation

1, F Out 2A Source Select Selects the source for AES output 2A • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

34 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Bank 2

2, 1 Out 2B Source Select Selects the source for AES output 2B • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 35

Chapter 3: Operation

2, 2 Out 3A Source Select**

Selects the source for AES output 3A • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

36 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

2, 3 Out 3B Source Select**

Selects the source for AES output 3B • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 37

Chapter 3: Operation

2, 4 Out 4A Source Select**

Selects the source for AES output 4A • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

38 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

2, 5 Out 4B Source Select**

Selects the source for AES output 4B • Ch01• Ch02• Ch03• Ch04• Ch05• Ch06• Ch07• Ch08• Ch09• Ch10• Ch11• Ch12• Ch13• Ch14• Ch15• Ch16• TstTone 1• TstTone 2• TstTone 3• TstTone 4

2, 6 Output Ch1A Format Selects the AES format for output channel 1A

• PCM

• Non-PCM1

• Auto2, 7 Output Ch1B Format Selects the AES format for output channel

1B• PCM

• Non-PCM1

• Auto2, 8 Output Ch2A Format Selects the AES format for output channel

2A• PCM

• Non-PCM1

• Auto2, 9 Output Ch2B Format Selects the AES format for output channel

2B• PCM

• Non-PCM1

• Auto2, A Output Ch3A

Format** Selects the AES format for output channel 3A

• PCM

• Non-PCM1

• Auto

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 39

Chapter 3: Operation

2, B Output Ch3B Format**

Selects the AES format for output channel 3B

• PCM

• Non-PCM1

• Auto2, C Output Ch4A

Format** Selects the AES format for output channel 4A

• PCM

• Non-PCM1

• Auto2, D Output Ch4B

Format** Selects the AES format for output channel 4B

• PCM

• Non-PCM1

• Auto2, E Output Ch1A Gain Adjusts gain for output channel 1A -18.0 to 18.0 dB (0.0)2, F Output Ch1B Gain Adjusts gain for output channel 1B -18.0 to 18.0 dB (0.0)Bank 3

3, 1 Output Ch2A Gain Adjusts gain for output channel 2A -18.0 to 18.0 dB (0.0)3, 2 Output Ch2B Gain Adjusts gain for output channel 2B -18.0 to 18.0 dB (0.0)3, 3 Output Ch3A Gain** Adjusts gain for output channel 3A -18.0 to 18.0 dB (0.0)3, 4 Output Ch3B Gain** Adjusts gain for output channel 3B -18.0 to 18.0 dB (0.0)3, 5 Output Ch4A Gain** Adjusts gain for output channel 4A -18.0 to 18.0 dB (0.0)3, 6 Output Ch4B Gain** Adjusts gain for output channel 4B -18.0 to 18.0 dB (0.0)3, 7 Output Ch1A Invert Invert control for output channel 1A • No

• Yes3, 8 Output Ch1B Invert Invert control for output channel 1B • No

• Yes3, 9 Output Ch2A Invert Invert control for output channel 2A • No

• Yes3, A Output Ch2B Invert Invert control for output channel 2B • No

• Yes3, B Output Ch3A

Invert** Invert control for output channel 3A • No

• Yes3, C Output Ch3B

Invert** Invert control for output channel 3B • No

• Yes3, D Output Ch4A

Invert** Invert control for output channel 4A • No

• Yes3, E Output Ch4B

Invert** Invert control for output channel 4B • No

• Yes3, F Output Ch1A Mute Enables muting for output channel 1A • Off

• OnBank 4

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

40 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

4, 1 Output Ch1B Mute Enables muting for output channel 1B • Off• On

4, 2 Output Ch2A Mute Enables muting for output channel 2A • Off• On

4, 3 Output Ch2B Mute Enables muting for output channel 2B • Off• On

4, 4 Output Ch3A Mute** Enables muting for output channel 3A • Off• On

4, 5 Output Ch3B Mute** Enables muting for output channel 3B • Off• On

4, 6 Output Ch4A Mute** Enables muting for output channel 4A • Off• On

4, 7 Output Ch4B Mute** Enables muting for output channel 4B • Off• On

4, 8 Output 1 Dither Mode

Selects the dithering mode for output channel pair 1

• None• On

4, 9 Output 2 Dither Mode

Selects the dithering mode for output channel pair 2

• None• On

4, A Output 3 Dither Mode**

Selects the dithering mode for output channel pair 3

• None• On

4, B Output 4 Dither Mute**

Selects the dithering mode for output channel pair 4

• None• On

4, C Output 1 Word Length

Selects the word length for output audio channel pair 1

• 24 bits• 20 bits• 16 bits

4, D Output 2 Word Length

Selects the word length for output audio channel pair 2

• 24 bits• 20 bits• 16 bits

4, E Output 3 Word Length**

Selects the word length for output audio channel pair 3

• 24 bits• 20 bits• 16 bits

4, F Output 4 Word Length**

Selects the word length for output audio channel pair 4

• 24 bits• 20 bits• 16 bits

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 41

Chapter 3: Operation

Bank 5

5, 1 Fade Rate Controls the rate of fading when channels are swapped or muted

0.0 to 10.0 sec (1.0)

5, 2 EDH Err Clear Clears the EDH error counter • No• Yes

Remote Control

[RO] SDI IP Video Std Fb Reports the detected SDI input video signal standard

• Unknown• 1080P25• 720P59.94• 720P60• 1080P23.98• 1080P24• 1080P29.97• 1080P30• 1080I25• 1035I29.97• 1035I30• 1080I25 (295M)• 1080I29.97• 1080I30• SD 525• SD 625• 720P50• 1080PsF23.98• 1080PsF24• 720P29.97• 720P30• 720P25• 720P23.98• 720P24• 1080PsF29.97• 1080PsF30

[RO] SDI IP Video Present Reports the presence of the input SDI video signal

• No• Yes

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

42 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

[RO] Y CRC Error Counter Reports the number of occurred luminance CRC errors

0 to 16777215

[RO] C CRC Error Counter Reports the number of occurred chrominance CRC errors

0 to 16777215

[RO] EDH Present Reports the presence of EDH in the input SDI signal

• Yes• No

[RO] EDH Error Counter Reports the number of occurred EDH errors 0 to 16777215 [RO] Group 1 Present Reports the presence of audio group 1 in the

SDI stream• No• Yes

[RO] Group 2 Present Reports the presence of audio group 2 in the SDI stream

• No• Yes

[RO] Group 3 Present Reports the presence of audio group 3 in the SDI stream

• No• Yes

[RO] Group 4 Present Reports the presence of audio group 4 in the SDI stream

• No• Yes

[RO] DARS Input Present Reports the presence of the DARS input signal

• No• Yes

[RO] DARS Locked to Video

Reports the locked status of the DARS input signal

• No• Yes

[RO] Group 1 Active Ch Reports the active channels from the control packet of audio group 1

• ====• 1===• =2==• 12==• ==3=• 1=3=• =23=• 123=• ===4• 1==4• =2=4• 12=4• ==34• 1=34• =234• 1234

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 43

Chapter 3: Operation

[RO] Group 2 Active Ch Reports the active channels from the control packet of audio group 2

• ====• 1===• =2==• 12==• ==3=• 1=3=• =23=• 123=• ===4• 1==4• =2=4• 12=4• ==34• 1=34• =234• 1234

[RO] Group 3 Active Ch Reports the active channels from the control packet of audio group 3

• ====• 1===• =2==• 12==• ==3=• 1=3=• =23=• 123=• ===4• 1==4• =2=4• 12=4• ==34• 1=34• =234• 1234

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

44 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

[RO] Group 4 Active Ch Reports the active channels from the control packet of audio group 4

• ====• 1===• =2==• 12==• ==3=• 1=3=• =23=• 123=• ===4• 1==4• =2=4• 12=4• ==34• 1=34• =234• 1234

[RO] Group 1 Smpl Rate Reports the sampling rate from the control packet of audio group 1

• 48.0 kHz• 44.1 kHz• 32.0 kHz• N/A• FreeRun

[RO] Group 2 Smpl Rate Reports the sampling rate from the control packet of audio group 2

• 48.0 kHz• 44.1 kHz• 32.0 kHz• N/A• FreeRun

[RO] Group 3 Smpl Rate Reports the sampling rate from the control packet of audio group 3

• 48.0 kHz• 44.1 kHz• 32.0 kHz• N/A• FreeRun

[RO] Group 4 Smpl Rate Reports the sampling rate from the control packet of audio group 4

• 48.0 kHz• 44.1 kHz• 32.0 kHz• N/A• FreeRun

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 45

Chapter 3: Operation

[RO] Group 1 Ch 1-2 Delay

Reports the delay, relative to video, of channel pair 1-2 in audio group 12

-699050.666 to 699050.645 ms

[RO] Group 1 Ch 3-4 Delay

Reports the delay, relative to video, of channel pair 3-4 in audio group 12

-699050.666 to 699050.645 msec

[RO] Group 2 Ch 1-2 Delay

Reports the delay, relative to video, of channel pair 1-2 in audio group 22

-699050.666 to 699050.645 msec

[RO] Group 2 Ch 3-4 Delay

Reports the delay, relative to video, of channel pair 3-4 in audio group 22

-699050.666 to 699050.645 msec

[RO] Group 3 Ch 1-2 Delay

Reports the delay, relative to video, of channel pair 1-2 in audio group 32

-699050.666 to 699050.645 msec

[RO] Group 3 Ch 3-4 Delay

Reports the delay, relative to video, of channel pair 3-4 in audio group 32

-699050.666 to 699050.645 msec

[RO] Group 4 Ch 1-2 Delay

Reports the delay, relative to video, of channel pair 1-2 in audio group 42

-699050.666 to 699050.645 msec

[RO] Group 4 Ch 3-4 Delay

Reports the delay, relative to video, of channel pair 3-4 in audio group 42

-699050.666 to 699050.645 msec

[RO] Group 1 DBN Error Reports if a data block number error has occurred in the group 1 de-embedder

• No• Yes

[RO] Group 1 Chksum Error

Reports if a checksum error has occurred in the group 1 de-embedder

• No• Yes

[RO] Group 1 Parity Error Reports if a parity error has occurred in the group 1 de-embedder

• No• Yes

[RO] Group 1 ECC Error Reports if an error correction code error has occurred in the group 1 de-embedder

• No• Yes

[RO] Group 2 DBN Error Reports if a data block number error has occurred in the group 2 de-embedder

• No• Yes

[RO] Group 2 Chksum Error

Reports if a checksum error has occurred in the group 2 de-embedder

• No• Yes

[RO] Group 2 Parity Error Reports if a parity error has occurred in the group 2 de-embedder

• No• Yes

[RO] Group 2 ECC Error Reports if an error correction code error has occurred in the group 2 de-embedder

• No• Yes

[RO] Group 3 DBN Error Reports if a data block number error has occurred in the group 3 de-embedder

• No• Yes

[RO] Group 3 Chksum Error

Reports if a checksum error has occurred in the group 3 de-embedder

• No• Yes

[RO] Group 3 Parity Error Reports if a parity error has occurred in the group 3 de-embedder

• No• Yes

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

46 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

[RO] Group 3 ECC Error Reports if an error correction code error has occurred in the group 3 de-embedder

• No• Yes

[RO] Group 4 DBN Error Reports if a data block number error has occurred in the group 4 de-embedder

• No• Yes

[RO] Group 4 Chksum Error

Reports if a checksum error has occurred in the group 4 de-embedder

• No• Yes

[RO] Group 4 Parity Error Reports if a parity error has occurred in the group 4 de-embedder

• No• Yes

[RO] Group 4 ECC Error Reports if an error correction code error has occurred in the group 4 de-embedder

• No• Yes

[RO] Input Ch01 to Ch16 Vbit Fb

Reports the validity bit status of input channels 01 to 16, respectively

• Off• On

[RO] Out Ch1A Format Fb Reports the AES format of output channel 1A

• PCM• Non-PCM

[RO] Out Ch1B Format Fb Reports the AES format of output channel 1B

• PCM• Non-PCM

[RO] Out Ch2A Format Fb Reports the AES format of output channel 2A

• PCM• Non-PCM

[RO] Out Ch2B Format Fb Reports the AES format of output channel 2B

• PCM• Non-PCM

[RO] Out Ch3A Format Fb**

Reports the AES format of output channel 3A

• PCM• Non-PCM

[RO] Out Ch3B Format Fb**

Reports the AES format of output channel 3B

• PCM• Non-PCM

[RO] Out Ch4A Format Fb**

Reports the AES format of output channel 4A

• PCM• Non-PCM

[RO] Out Ch4B Format Fb**

Reports the AES format of output channel 4B

• PCM• Non-PCM

[RO] Out Ch1A Status Reports the status (peak/silence/normal) of output channel 1A

• Peak• Silence• Normal

[RO] Out Ch1B Status Reports the status (peak/silence/normal) of output channel 1B

• Peak• Silence• Normal

[RO] Out Ch2A Status Reports the status (peak/silence/normal) of output channel 2A

• Peak• Silence• Normal

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 47

Chapter 3: Operation

[RO] Out Ch2B Status Reports the status (peak/silence/normal) of output channel 2B

• Peak• Silence• Normal

[RO] Out Ch3A Status** Reports the status (peak/silence/normal) of output channel 3A

• Peak• Silence• Normal

[RO] Out Ch3B Status** Reports the status (peak/silence/normal) of output channel 3B

• Peak• Silence• Normal

[RO] Out Ch4A Status** Reports the status (peak/silence/normal) of output channel 4A

• Peak• Silence• Normal

[RO] Out Ch4B Status** Reports the status (peak/silence/normal) of output channel 4B

• Peak• Silence• Normal

[RO] HDX Hardware ID Reports the physical hardware identification of the Audio De-embedding / Processing Amplifier IC

Current Version

[RO] Software Version Reports the software version Current Version

1 Use Non-PCM channel format when passing compressed audio such as Dolby-E.2 These read-only parameters indicate the audio and video timing relationship, as indicated in theassociated audio group control packet (see SMPTE 299M section 6.2.4). In regard to the embeddedaudio in the HD stream, positive values indicate that the video leads the audio, while negative valuesindicate that the audio leads the video. Note that these parameters only notify the network if there is achange in value; typically, these values do not change.

Table 3-7. Parameter Options (Continued)Bank, Rotary Switch

Parameter Name Function Options

48 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

LEDs and Alarms

Monitoring LEDsThe HDX6801+B2/C2 and HDX6801+B4/C4 has 10 monitoring LEDs that serve as a quick monitoring reference. Figure 3-1 shows the general location of the monitoring LEDs on a generic 6800+ module. The table that follows, Table 3-8, describes each LED in more detail.

Figure 3-1. Location of Card-Edge LEDs

The 10 monitoring LEDs on the card-edge of HDX6801+ modules are identified in Figure 3-1 (left to right).

Table 3-8. Monitoring LEDs

LED Description Color IndicationAuto Indicates if auto detection of

the input video signal is activated

• GREEN: Auto detect enabled

• OFF: Auto detect disabled

720P Indicates if a 720P video source is present

• GREEN: 720P video present

• OFF: 720P video not present

Monitoring LEDsModule status LEDs

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 49

Chapter 3: Operation

1080I Indicates if a 1080I video source is present

• GREEN: 1080I video present

• OFF: 1080I video not present

1035I Indicates if a 1035I video source is present

• GREEN: 1035I video present

• OFF: 1035I video not present

1080P/sF Indicates if a 1080P/sF video source is present

• GREEN: 1080P/sF video present

• OFF: 1080P/sF video not present

525 Indicates if a 525 video source is present

• GREEN: 525 video present

• OFF: 525 video not present

625 Indicates if a 625 video source is present

• GREEN: 625 video present

• OFF: 625 video not present

Reference Present N/A N/A

Freeze N/A N/A

DARS Present Indicates if the DARS signal is present

• GREEN: DARS is present

• OFF: DARS is not present

AUDIO1 Reports the presence of audio group 1 in the SDI stream

• GREEN: Group 1 audio is present

• OFF: Group 1 audio is not present

AUDIO2 Reports the presence of audio group 2 in the SDI stream

• GREEN: Group 2 audio is present

• OFF: Group 2 audio is not present

Table 3-8. Monitoring LEDs (Continued)

LED Description Color Indication

50 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Module Status LEDsThe HDX6801+B2/C2 and HDX6801+B4/C4 modules do not have any card-edge alarms. Instead, module status LEDs on the corner of the module light up if an error is detected. See Figure 3-1 on page 49 for the location of these LEDs, and Table 3-9 below for a definition of the LED colors.

AUDIO3 Reports the presence of audio group 3 in the SDI stream

• GREEN: Group 3 audio is present

• OFF: Group 3 audio is not present

AUDIO4 Reports the presence of audio group 4 in the SDI stream

• GREEN: Group 4 audio is present

• OFF: Group 4 audio is not present

Table 3-8. Monitoring LEDs (Continued)

LED Description Color Indication

NoteIf the LED is flashing red, please contact your product Customer Service representative.

Table 3-9. Module Status LED Descriptions

LED Color Sequence MeaningOff There is no power to the module; the module

is not operational.

Green There is power to the module; the module is operating properly.

Red There is an alarm condition.

Flashing red The module has detected a hardware/firmware fault.

Amber The module is undergoing configuration.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 51

Chapter 3: Operation

AlarmsThe table below describes the specific alarms for HDX6801+B2/C2 and HDX6801+B4/C4 modules. You can only identify specific alarms using a software control application (for example, +Pilot Lite or Pilot). For more information, see the following:• Table 3-10 (below) for a list of HDX6801+B2/C2 and

HDX6801+B4/C4B2 alarms that are logged and monitored via CCS applications

• The appropriate software control user manual or online help for more information

Table 3-10. Alarm Descriptions

Alarm Name Alarm Description Alarm LevelSDI IP Video Present Loss of SDI Major

DARS Input Present Loss of DARS Minor

DARS Locked to Video

Loss of DARS locked Minor

Group 1 DBN Error Group1 demux error Minor

Group 1 Chksum Error

Group1 demux error Minor

Group 1 Parity Error Group1 demux error Minor

Group 1 ECC Error Group1 demux error Minor

Group 2 DBN Error Group2 demux error Minor

Group 2 Chksum Error

Group2 demux error Minor

Group 2 Parity Error Group2 demux error Minor

Group 2 ECC Error Group2 demux error Minor

Group 3 DBN Error Group3 demux error Minor

Group 3 Chksum Error

Group3 demux error Minor

Group 3 Parity Error Group3 demux error Minor

Group 3 ECC Error Group3 demux error Minor

Group 4 DBN Error Group4 demux error Minor

52 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 3: Operation

Group 4 Chksum Error

Group4 demux error Minor

Group 4 Parity Error Group4 demux error Minor

Group 4 ECC Error Group4 demux error Minor

LossOfAudioAlarm Loss of audio Major

Video Standard Mismatch

Video format selection error Major

Table 3-10. Alarm Descriptions (Continued)

Alarm Name Alarm Description Alarm Level

NoteLossOfAudioAlarm activates when no embedded audio groups are detected in the SDI stream; the alarm deactivates when any embedded audio groups are detected.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 53

Chapter 3: Operation

54 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 4

Specifications

OverviewThe following specification tables appear in this chapter:• “SDI Video Input” on page 56• “DARS Input” on page 56• “AES Balanced Output (HDX6801+B2/B4 Only)” on page 57• “AES Unbalanced Output (HDX6801+C2/C4 Only)” on page 57• “SDI Video Output (Reclocked)” on page 58• “Propagation Delay” on page 58• “Power Consumption” on page 59• “Operating Temperature” on page 59

Specifications and designs are subject to change without notice.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 55

Chapter 4: Specifications

Inputs

SDI Video Input

DARS Input

Item SpecificationNumber 1

Standard SMPTE 292M and 296M (50, 59.94, and 60 Hz rates) HD-SDI and 259M-C SD-SDI

Connector BNC (IEC169-8)

Impedance 75Ω

Return loss • >18 dB (typical) from 5 MHz to 1485 MHz HD-SDI mode

• >18 dB (typical) to 270 MHz SD-SDI mode

Equalization Adaptive cable equalization for up to 393 ft (120 m) (typical) of Belden 1694A coaxial cable for HD-SDI and 753 ft (230 m) (typical) of Belden 8281 coaxial cable for SD-SDI video

Item SpecificationType • HDX6801+B2/B4: Unbalanced,

AC coupled and balanced, transformer coupled (parameter selectable)

• HDX6801+C2/C4: Unbalanced, AC coupled

Connector • HDX6801+B2/B42: BNC (IEC169-8) or 3-pin WECO

• HDX6801+C2/C4: BNC (IEC169-8)

Impedance 75Ω (unbalanced)/110Ω (balanced)

Return loss >25 dB, 0.1 to 6 MHz (applies to coax input only)

56 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 4: Specifications

Outputs

AES Balanced Output (HDX6801+B2/B4 Only)

AES Unbalanced Output (HDX6801+C2/C4 Only)

Item SpecificationType Balanced, transformer coupled

Connector 3-pin WECO

Impedance 110Ω, ±20% (0.1 to 6 MHz)

Signal amplitude 2 to 7 V pk-to-pk into 110Ω load

Audio rate 48 kHz

Jitter ±20 ns

Rise/fall time 5 to 30 ns (10% to 90%)

Bits 16, 20, or 24

Channel status and user bits Maintained, but professional mode, 48 kHz (see “Appendix B: Audio Bit Manipulation” for more information)

Item SpecificationStandard AES 3, SMPTE276M

Type Unbalanced, AC coupled

Connector BNC (IEC169-8)

Impedance 75Ω

Return loss >25 dB, 0.1 to 6 MHz

Signal amplitude 1.0 V pk-to-pk ±10% into 75Ω load

Audio rate 48 kHz

Rise/fall time 30 to 44 ns (10% to 90%)

Bits 16, 20, or 24

Channel status and user bits Maintained, but professional mode, 48 kHz (see “Appendix B: Audio Bit Manipulation” for more information)

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 57

Chapter 4: Specifications

SDI Video Output (Reclocked)

Propagation Delay

Item SpecificationNumber 4

Standard • SMPTE 292M HD-SDI • SMPTE 259M-C SD-SDI over coaxial

cable

Connector BNC (IEC169-8)

Impedance 75Ω

Return loss • >18 dB (typical) from 5 MHz to 1485 MHz HD-SDI mode

• >18 dB (typical) to 270 MHz SD-SDI mode

Signal level 800 mV ±10%

D.C. offset 0.0 V pk-to-pk ±0.5 V

Rise/fall time • < 270 ps, within 100 ps of each other HD-SDI mode

• 400-1500 ps (20 to 80% amplitude) SD-SDI mode

Overshoot <10% of amplitude

Jitter • >100 kHz: <135ps10 Hz to 100 kHz: <675 psin HD-SDI mode

• < 0.2 UI (740 ps) peak-to-peak in SD-SDI mode

Item SpecificationVideo 4.5 ns in SD-SDI mode and

1 ns in HD-SDI mode

Audio (minimum delay setting) < 1 ms in HD and SD-SDI modes

58 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Chapter 4: Specifications

Power ConsumptionThe total power consumption for the HDX6801+B2/C2 and HDX6801+B4/C4 is approximately 7 W from the positive rail and 0.3 W from the negative rail.

Operating TemperatureThe operating temperature for HDX6801+B2/C2 and HDX6801+B4/C4 modules is 41° to 113°F (5° to 45°C).

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 59

Chapter 4: Specifications

60 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Appendix A

Communication and ControlTroubleshooting Tips

OverviewFind the following troubleshooting information in this appendix:• “General Troubleshooting Steps” on page 62• “Software Communication and Control Issues” on page 63• “Hardware Communication and Control Issues” on page 67• “Contacting Customer Service” on page 67

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 61

Appendix A: Communication and Control Troubleshooting Tips

General Troubleshooting StepsFollow these steps in troubleshooting 6800+ product problems:1. Review the “Software Communication and Control Issues” on

page 63 outlined in this chapter.2. Search this product manual and other associated documentation for

answers to your question.Product documentation (including manuals, online help, application notes, erratas, product release notes, and more) can be found on our Web site at www.broadcast.harris.com/leitch (Support section), along with technical support information, training information, product downloads, and the product knowledge base.

3. Contact your product Customer Service representative if, after following these initial steps, you cannot resolve the issue.To contact Customer Service, see “Contacting Customer Service” on page 67.

NoteAssociated documentation for 6800+ series products can generally be found in the product-specific manual that accompanies every module, in the FR6802+ Frame Installation and Operation Manual, and in the 6800+ Safety Instructions and Standards Manual.

62 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Appendix A: Communication and Control Troubleshooting Tips

Software Communication and Control Issues• “+ Pilot Lite Fails to Communicate with Installed Modules” on

page 63• “+ Pilot Lite Does Not Find All Modules in Frame” on page 65• “+ Pilot Lite or CCS Software Application Not Responding” on

page 65• “+ Pilot Lite Cannot Control a Module Showing

in the Control Window” on page 65• “+ Pilot Lite Status Bar Reports “Not Ready”” on page 66• “CCS Software Application or Remote Control Panel Does Not

Communicate with Module” on page 66• “Alarm Query Fails When a Device Reboots” on page 66

+ Pilot Lite Fails to Communicate with Installed ModulesConfirm that the following items are not the reason for the communication failure:• The proper module slot has not been specified (+ Pilot Lite is not

communicating with the appropriate slot). See your FR6802+ Frame Installation and Operation Manual for more information on slot identification.

• The COM port is used elsewhere (Check that the correct COM port is configured in + Pilot Lite and that another application is not using that COM port).

• The actual frame ID does not match the two DIP switch settings in the back of the frame (+ Pilot Lite is not communicating with the proper frame). See your FR6802+ Frame Installation and Operation Manual for more information on frame ID switch settings.

• A null modem cable is not being used. Between the PC running + Pilot Lite and the FR6802+ frame, there should be a null RS-232 modem cable. At minimum, this requires that pins 2 and 3 are crossed and 5 to 5 for ground.

• An ICE6800+ module is installed in the frame (+ Pilot Lite control is disabled if an ICE6800+ module is installed in the frame; ICE6800+ modules are used for CCS control).

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 63

Appendix A: Communication and Control Troubleshooting Tips

• A legacy 6800 series product is in the frame. To communicate with + Pilot Lite, modules must be from the 6800+ product family.+ Pilot Lite cannot communicate with legacy 6800 series products. Although they can be installed in a FR6802+XF frame and work using card edge controls, 6800 series cards cannot be discovered or controlled by + Pilot Lite.

• The back module has bent pins. To determine if the module has bent pins, follow this procedure:a. Unplug the front module. b. Unscrew and remove the back module.c. View the 20-pin spring connector at the bottom of the back

module. See Figure A-1.

Figure A-1. Connector on 6800+ Back Module

This connector should not have any bent or pressed pins. Even a slightly depressed or bent pin may cause genlock issues.

d. If there are bent pins, carefully re-position them to their correct positions. If this is not possible, then a back module can be exchanged from the manufacturer.

20-Pin Connector

64 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Appendix A: Communication and Control Troubleshooting Tips

+ Pilot Lite Does Not Find All Modules in FrameIf a discovery is started too soon after frame power-up, + Pilot Lite will not find all the installed modules. Refresh + Pilot Lite (File > Refresh), and ensure that installed modules are fully powered-up before discovery.If a module is plugged into the frame after a discovery, + Pilot Lite will not automatically detect the module. Refresh + Pilot Lite (File > Refresh) to discover the newly installed module.If a legacy 6800 series product is in the frame, + Pilot Lite will not detect it. + Pilot Lite cannot communicate with legacy 6800 series products. Although they can be installed in FR6802+QXF and FR6802+XF frames and work using card edge controls, they will not be discovered or controlled by + Pilot Lite. For + Pilot Lite to find a module, it must be from the 6800+ product family.

+ Pilot Lite or CCS Software Application Not Responding+ Pilot Lite and a CCS application such as Navigator or Pilot cannot run on the same PC at the same time. Both applications can be installed, but only one can be opened at a time.

+ Pilot Lite Cannot Control a Module Showing in the Control Window

There are three possible causes for this problem: • Did you physically set the jumper for local control? If so, set this

jumper to the REM position for remote control.• Does the card name in the control window physically match the

card type in the frame? • Is the module properly seated in the frame? Check the positioning

of the module in its slot in the frame.• Does the Control window indicate the device is “ready”? The

device may be powered off or disconnected from the network.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 65

Appendix A: Communication and Control Troubleshooting Tips

+ Pilot Lite Status Bar Reports “Not Ready”+ Pilot Lite reports each device’s connection status in the status bar. If the connection status message reads “Not Ready,” check the following:• The position of the module -- it may not be properly seated in the

frame.• The frame’s network connection.If the status bar still reports no status or “Not Ready” for the frame or device, try restarting + Pilot Lite.

CCS Software Application or Remote Control Panel Does Not Communicate with Module

CCS software applications (such as Pilot, CoPilot, and Navigator) and remote control panels require the purchase and installation of an ICE6800+ module in an FR6802+ frame in order to communicate remotely via Ethernet.

Alarm Query Fails When a Device RebootsWhen you reboot a device connected to your PC, the alarm traffic hitting the network may cause an alarm query request to time out and fail. While the query does not automatically retry, it will post an “Alarm query failed” message to the Diagnostics window.To clear an “Alarm query failed” message, right-click inside the Diagnostics window, and then select Refresh from the resulting context menu.

66 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Appendix A: Communication and Control Troubleshooting Tips

Hardware Communication and Control Issues

Frames Fail to Communicate with the PC after a Power Failure

You must exit the software and restart after the frame recovers from its power failure. To restore communications between the PC and the frames, ensure that the frames have three or more minutes to recover from the power failure before you exit the application and restart the PC.

Module Does Not Seem to WorkAlthough the following troubleshooting tips may seem obvious, please take the time to ensure the following:• All appropriate rear connections are securely made• The board is securely installed (with no bent pins)• The frame is turned on

Contacting Customer ServiceWe are committed to providing round-the-clock, 24-hour service to our customers around the world. Visit our Web site atat www.broadcast.harris.com/leitch (Support section) for information on how to contact your product Customer Service team in your geographical region.

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 67

Appendix A: Communication and Control Troubleshooting Tips

68 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Appendix B

Audio Bit Manipulation

OverviewThe tables in this appendix contain information on the manipulation of bits that occur when using HDX6801+B2/C2 and HDX6801+B4/C4 modules.The following items are documented:• “Manipulating Channel Status Bits (C-Bit)” on page 70• “Manipulating Validity and User Bits (V-Bit and U-Bit)” on

page 73• “Identifying Audio Characteristics (Audio Sampling Frequency

and Word Length)” on page 74

Table B-1. Description of Short Forms in the Appendix

RX Key TX KeyN=Not recognized N=Not transmitted

Y=Recognized Y=Transmitted

S=Recognized and stored, passed-through, or both

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 69

Appendix B: Audio Bit Manipulation

Manipulating Channel Status Bits (C-Bit)Table B-2. Channel Status (C-Bits) Data Description

Byte Bit Function RX TX Remarks

0 0 [0] Consumer Use [1] Professional Use

N Y

NY

• RX ignores bit• TX sets bit to 1

0 1 [0] Audio [1] Non-Audio

SS

YY

• RX sets up audio channel to pass data (Gain=0 dB, Invert=Off)

• TX bit passed unmodified or forced, according to Output Chxx Format and Out Ch4B Format Fb parameters

0 2 to 4 [000] Not Indicated [100] No Emphasis [110] 50/15 µs [111] CCITT J.17

SSSS

YYYY

• RX ignores bits• TX passed bits

unmodified

0 5 [0] Locked [1] Unlocked

N N

Y N

• RX ignores bits• TX sets bit to 0

0 6 to 7 [00] Not indicated [01] 48 kHz [10] 44.1 kHz [11] 32 kHz

YYYY

N YNN

• RX ignores bits • TX sets bits to [01]

1 0 to 3 [0000] Not indicated [0001] Two channel [0010] Mono [0011] Prim/sec [0100] Stereo [0101] to [1111] Undefined

NNNNNN

YNNNNN

• RX ignores bits • TX sets bits to [0000]

1 4 to 7 [0000] Not indicated [0001] 192 bit block [0010] AES18 (HDLC) [0011] User defined [0100] to [1111] Undefined

SSSSS

Y YYYY

• RX ignores bits• TX passes bits

unmodified

70 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Appendix B: Audio Bit Manipulation

2 0 to 2 [000] Aux. bit use is not indicated[001] Aux. bit use is audio data[010] Aux. bit use is co-ordination signal[011] to [111] Undefined

N N N N

YYNN

• RX ignores bits• TX sets bits according to

transmitted word length

2 3 to 5 [000] Not indicated [001] Max Length - 1 [010] Max Length - 2 [011] Max Length - 3 [100] Max Length - 4 [101] Max Length [110] to [111] Undefined

N N N N N N N

NNN NY YN

• RX ignores bits• TX sets bits according to

transmitted word length

2 6 to 7 [00] Alignment level not indicated[01] Alignment to SMPTE RP155[10] Alignment to EBU R6811] Reserved

N Y • RX ignores bits• TX sets bits to [00]

3 0 to 6 bit 7 = 0: Channel numberbit 7 = 1: [0,1,2,3] Channel number[4,5,6] Multi-channel mode

N Y • RX ignores bits• TX sets bits to [0000000]

3 7 [0] Undefined multi-channel mode[1] Defined multi-channel mode

N Y • RX ignores bits• TX sets bits to [0]

4 0 to 1 [00] Not a reference [01] Grade 1 reference [10] Grade 2 reference [11] Undefined

N N N N

Y N NN

• RX ignores bits• TX sets bits to [00]

4 2 Reserved N Y • RX ignores bits• TX sets bits to [0]

Table B-2. Channel Status (C-Bits) Data Description (Continued)

Byte Bit Function RX TX Remarks

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 71

Appendix B: Audio Bit Manipulation

4 3 to 6 [0000] Not indicated[1000] 24 kHz[0100] 96 kHz[1100] 192 kHz[1001] 22.05 kHz[0101] 88.2 kHz[1101] 176.4 Hz[1111] User defined

N Y • RX ignores bits• TX sets bits to [0000]

4 7 [0] Sample frequency not scaled[1] Sample frequency scaled by 1/1.001

N Y • RX ignores bits• TX sets bits to [0]

5 0 to 7 Reserved N Y • RX ignores bits• TX sets bits to

[00000000]

6 to 9 0 to 7 Alphanumeric channel origin data S Y • RX ignores bits• TX passed bits

unmodified

10 to 13 0 to 7 Alphanumeric channel destination data S Y • RX ignores bits• TX passed bits

unmodified

14 to 17 0 to 7 Local sample address code S Y • RX ignores bits• TX passed bits

unmodified

18 to 21 0 to 7 Time-of-day sample address code S Y • RX ignores bits• TX passed bits

unmodified

22 0 to 3 Reserved N Y • RX ignores bits• TX passed bits

unmodified

22 4 Bytes 0 to 5 reliability flag N Y • RX ignores bits• TX passed bits

unmodified

Table B-2. Channel Status (C-Bits) Data Description (Continued)

Byte Bit Function RX TX Remarks

72 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Appendix B: Audio Bit Manipulation

Manipulating Validity and User Bits (V-Bit and U-Bit)

22 5 Bytes 6 to 13 reliability flag S Y • RX ignores bits• TX passed bits

unmodified

22 6 Bytes 14 to 17 reliability flag S Y • RX ignores bits• TX passed bits

unmodified

22 7 Bytes 17 to 21 reliability flag S Y • RX ignores bits• TX passed bits

unmodified

23 0 to 7 CRC Y Y • RX ignores bits• TX calculates CRC on

output

Table B-2. Channel Status (C-Bits) Data Description (Continued)

Byte Bit Function RX TX Remarks

Table B-3. V-Bit and U-Bit Data Descriptions

Item RX TX Remarks

Validity (V) bit S Y • RX optionally mutes data if enabled

• TX passes bit unmodified

User (U) bit S Y • RX ignores bits• TX passed bits unmodified

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 73

Appendix B: Audio Bit Manipulation

Identifying Audio Characteristics (Audio Sampling Frequency and Word Length)

Table B-4. Audio Sampling Frequency and Word Length

Item Remarks

Audio sampling frequency • RX: 48 kHz• TX: 48 kHz

Audio word length • RX: 16 to 24 bits• TX: 16 to 24 bits

74 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Index

Keywords

Aactive channels 44Add Upgrade Files box 20AES format 47AES format select 39AES output format 47AES output source 32alarm query

failed 66request 66

alarms 52application not responding 65application notes 62audience viiaudio bit manipulation 69audio channel muting 32audio characteristics, identifying 74audio delay 46audio sampling frequency 74auto-detection 3

Bback connectors 6–9back module 64balanced output, AES 57bank, selecting 28

bent pins 64bit manipulation, audio 69

CCCS application 65CCS software 16, 63, 66changing parameter settings 28channel status bits, manipulating 70checksum error 46chrominance CRC error counter 31chrominance CRC errors 43contacting customer service 67control problems 65control window 65CoPilot 16, 66Copyright information iicorrecting a failed upgrade 20cross-functional parameter changes 25customer service, contacting 67

DDARS input 56DARS input locked status 43DARS input signal presence 43DARS input type 31data block number error 46

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 75

Index

DBN (Data Block Number) error reporting 31DC offset 58default parameter settings, recalling 29delay 46delay for de-embedded audio channels 31delay setting, minimum 58description, general 2DIP switch settings on frame 63discovery 19, 65discovery failure 65dithering mode 41drag-and-drop method of upgrading 19

EEDH error counter 42EDH errors 43errata 62error correction code error 46

Ffactory defaults 29factory settings, recalling 32fade rate 42failure to communicate 67features 3file transfer 16, 20firmware upgrade 16

correcting failed 20FR6802+ frames 62frame ID 63frames 12front module 4, 13

Ggain, output 25

Hhardware ID 48hardware version 29HD operating mode parameters 27

IICE6800+ 16, 63, 66identifying audio characteristics 74impedance 58input video signal standard 31input video signal standard reporting 42input, DARS 56input, SDI video 56inputs 3installation

troubleshooting 65Installing and removing modules 15invert control 40invert, output 25

Jjitter 58

Kknowledge base 62

LLEDs

module status 51monitoring 49

legacy 6800 products 64local control 14, 65locked status 43luminance CRC error counter 31luminance CRC errors 43

76 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual

Index

Mmanipulating channel status bits 70minimum delay setting 58Module

installation and removal 15module not found 65module status LEDs 51module types 2monitoring LEDs 49mute fade rate 42muting, enable 40

NNavigation Properties box 19Navigator 16, 66network connection 66not ready status 65null modem cable 63

OObtaining Documents viiioffset, DC 58online help 62operating temperature 59output audio word length 41output channel status 47output gain 25, 40output invert 25output source, AES 32outputs 3

balanced 57unbalanced 57

overshoot 58

Ppacking list 13parameter settings, changing 28

parameter settings, default 29parity error 46Pilot 16, 66Pilot Lite 63power

failure 67power consumption 12, 59Precautions, safety xiiproduct description 2product downloads 62product release notes 62Product servicing ixpropagation delay 58

Rreboot device 20, 66recall factory settings 32reclocked SDI video output 58refresh 65release notes 62REM/LOC jumper 14remote control 14, 65Removing and installing modules 15return loss 58Returning a product ixRevision History viirise/fall time 58RoHS-compliance x

SSafety Instructions and Standards manual 62Safety precautions xiisampling rate 45SD operating mode parameters 27SDI video input 56SDI video output 58selecting bank 28serial communication 63

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 77

Index

setting jumpers 14Shipping and unpacking a product ixsignal flow 10signal level 58software upgrade 16

correcting failed 20software version 29, 48specifications 55–59standard, video 58Standards

RoHS compliance xWEEE compliance xi

status not ready 65Support documents viiiswap fade rate 42

Ttechnical support 62trademarks and copyrights iitraining information 62troubleshooting 61–67

communication and control 63general 62

Uu-bit 73unbalanced outputs, AES 57unpacking 13Unpacking and shipping a product ixupgrading firmware 16

correcting failed 20user bits 73

Vvalidity bits 73v-bit 73video output 58

video standard 58

WWarranty information iiWEEE compliance xiword length 74

output audio 41Writing Conventions viii

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 78

Index

HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual 79

Index

80 HDX6801+B2/C2 and HDX6801+B4/C4 Installation and Operation Manual


Recommended