Sentry -48VDC PDUs and Remote Power Managers
Server TechnologySolutions for the Data Center Equipment Cabinet
STI Reseller Training
February 2006
Who needs -48 VDC Equipment?
Any Enterprise or Service Providers that rely on -48VDC internetworking equipment such as:
•Routers
•ATM Switches and
•DSLAMs
Server TechnologySolutions for the Data Center Equipment Cabinet
Sentry -48VDC provides the following functionality:
• Power Distribution : distribute dual power input feeds to multiple equipment units in a rack or cabinet. All models.
• Power Measurement : Extend network management capabilities and protect the investment in internetworking devices with SNMP traps and individual load sensing per output pair. Remote Power Manager (RPM) units only.
• Remote Power Control : Perform a remote reboot and fix “locked-up” or failing equipment. RPM units.
• Power Protection : GMT fuses, TPA fuses, TPC fuses and Circuit-Breakers provide per-output over-current and fault protection. Protection type varies by model.
Server TechnologySolutions for the Data Center Equipment Cabinet
• Each output terminal connection is protected by a TPC fuse
• TCP/IP Control: to remotely Power On, Power Off or Reboot supported equipment via:
– SSH, SSL, HTTP/HTTPS (HTML Web GUI), SNMP and Telnet.
– Out-of-Band access (RS232/Console)– Optional Global Security Modem
supports Passwords and Call-Back
• LDAP/Active Directory and TACACS+ Authentication and Authorization support
– provides additional security and simplifies user-management for large-scale deployments
• Grouping of output pairs (supports multiple supply equipment)
Server TechnologySolutions for the Data Center Equipment Cabinet
Key Features• Logging of All Authentications
- Power actions - Configuration changes - System events
• Flash-upgrade via single FTP - Configuration upload/download support via built in FTP server
• Temperature & Humidity Monitoring • NEBS Compliant• Multiple Users Simultaneous Access
•104 user accounts
•18 simultaneous sessions
• Basic Units (PDU400 and PDU420)
• Rugged and reliable DC power distribution
• Qty (2) 50/100/200A DC Power Input Feeds (A Feed and B Feed); Supports dual power supply routers and networking gear
• Multiple DC Outlet Circuits: Protected by GMT or TPA fuses
• Outlet Circuit Protection: Fast acting fuse with positive visual indication of a blown fuse
– fuses are UL Recognized as a ‘hot’ disconnect/re-connect switch
• Variable Amperage and Interchangeable Fuses: Match the fuse value to the amp rating of each device
• Up to (24) output terminal connections
• 1U or 2U 19” chassis fits equipment cabinets or racks
• Fail-Safe: Model allows either the A or B power in-feed to support the entrire output load if a power loss occurs on one input
• NEBS Compliant
Server TechnologySolutions for the Data Center Equipment Cabinet Basic Products
Server TechnologySolutions for the Data Center Equipment Cabinet
Sentry -48VDC Basic Product Line
PDU400-0-2 Power Input• Qty (2) 100A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (16) (.5A to 15A) max output pairs protected with GMT fuses.•Qty (8) (5 to 50A) max output pairs protected with TPA fuses.• Basic power distribution
PDU400-0-3 Power Input• Qty (2) 200A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (16) (.5A to 15 A) max output pairs protected by GMT fuses.•Qty (8) (5 to 50A) max output pairs protected by TPA fuses.•Basic power distribution
Server TechnologySolutions for the Data Center Equipment Cabinet
Sentry -48VDC Basic Product Line
PDU400-F-2 Power Input• Qty (2) 100A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (16) (.5A to 15A) max output pairs protected with GMT fuses.•Qty (8) (5 to 50A) max output pairs protected with TPA fuses• Fail Safe
PDU420-0-1 Power Input• Qty (2) 50A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (20) (.5A to 15 A) max output pairs protected by GMT fuses.•Basic power distribution
• Switched Units/Remote Power Managers: 4805, 4820, 4835, 4870 and 4805/35
• Remote Power Management: Combines intelligent power distribution. Load-measurement per output pair, and remote power control
• Qty (2) 100-Amp DC Power Input Feeds (A Feed and B Feed); Supports multiple power supply routers and networking gear
• Master XLS and Expansion XMS expands number of outputs controlled through a single interface and eliminates single-point-of-failure concerns
• Multiple DC Outlet Circuits: Protected by GMT or TPC fuses (4805, 4870, 4805/35) or circuit-breakers (4820, 4835)
• Fuses are UL Recognized as ‘hot’ disconnect/re-connect switch
• Circuit-breakers are Push-to-close/Pull-to-open for use as a switch
• Variable Amperage and Interchangeable Fuses: Match the fuse value to the amp rating of each outlet circuit
• IP Access: For Remote Power On, Power Off or Reboot
• SNMP Traps and Email notification of events
• Environmental Monitoring – Support for two Temperature+Humidity probes; 4805, 4870 and 4805/35 master XLS models only
• Load Sense: Current draw per output pair
• NEBS Complaint
Server TechnologySolutions for the Data Center Equipment Cabinet
Switched Products
Server TechnologySolutions for the Data Center Equipment Cabinet
Sentry -48VDC Switched Product Line
4805-XLS-16 & 4805-XMS-16 Power Input• Qty (2) 100A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (16) 10A max load-measured output pairs protected with GMT fuses.• Switched outputs
4805/35-XLS-12 & 4805/35-XMS-12 Power Input• Qty (2) 100A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (8) 10A max load-measured output pairs protected with GMT fuses• Qty (4) 70A max load-measured output pairs protected with TPC fuses. Rated for 70A switching and up-to 75A fusing• Switched outputs
Server TechnologySolutions for the Data Center Equipment Cabinet
Sentry -48VDC Switched Product Line
4820-XLS-8 & 4820-XMS-8 Power Input• Qty (2) 100A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (8) 20A load-measured output pairs with 25A push-to-reset, pull-to-break circuit breakers; Switched outputs• Qty (1) 5A non-switched, non-measured Auxiliary output with 5A circuit breaker
4835-XLS-4 & 4835-XMS-4 Power Input• Qty (2) 100A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (4) 35A load-measured output pairs with 40A push-to-reset pull-to-break circuit breakers; Switched outputs• Qty (1) 5A non-switched, non-measured Auxiliary output with 5A circuit breaker
Server TechnologySolutions for the Data Center Equipment Cabinet
Sentry -48VDC Switched Product Line
4870-XLS-4 & 4870-XMS-4 Power Input• Qty (2) 100A power input terminal blocks (+/- & G), -48 VDCPower Output• Qty (4) 70A max load-measured output pairs protected with TPC fuses. Rated for 70A switching and up-to 75A fusing; Switched outputs• Qty (1) 5A non-switched, non-measured Auxiliary output with 5A circuit breaker (not pictured)
Fuses
Server TechnologySolutions for the Data Center Equipment Cabinet
GMT Fuse Values
1/2, 3/4, 1, 1.5, 2, 3, 4, 5, 7.5 or 10-amps
TPC Fuse Values
25, 30, 40, 50, 60 or 75-Amps TELPOWER
TPC-40AMPS
Bussmann
TELPOWER
TPC-40AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-30AMPS
Bussmann
TELPOWER
TPC-30AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-50AMPS
Bussmann
TELPOWER
TPC-50AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-60AMPS
Bussmann
TELPOWER
TPC-60AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-75AMPS
Bussmann
TELPOWER
TPC-75AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-25AMPS
Bussmann
TELPOWER
TPC-25AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-20AMPS
Bussmann
TELPOWER
TPC-20AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-15AMPS
Bussmann
TELPOWER
TPC-15AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-12AMPS
Bussmann
TELPOWER
TPC-12AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-10AMPS
Bussmann
TELPOWER
TPC-10AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-8AMPS
Bussmann
TELPOWER
TPC-8AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-7AMPS
Bussmann
TELPOWER
TPC-7AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-6AMPS
Bussmann
TELPOWER
TPC-6AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-5AMPS
Bussmann
TELPOWER
TPC-5AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-4AMPS
Bussmann
TELPOWER
TPC-4AMPS
Bussmann
FUSE
FUSE
TELPOWER
TPC-3AMPS
Bussmann
TELPOWER
TPC-3AMPS
Bussmann
FUSE
FUSE
Bussmann TelPower Compact (TPC) fuses
Fuses are:-DC Specific-High interrupt rating (100,000 Amps)-Time delay/current limiting-User Selectable-Spare fuse holder (on each unit)
Note: See handouts for additional fuse and circuit breaker information
Remote Power Management Capabilities with SNMP traps
• Load Sense – measures load in amps that each connected server, internetworking device and telecom unit is drawing
• Input feed/Outlet On-Sense - Verifies voltage at each power input/outlet connection.
• External Temperature and Humidity Sense – makes sure that remote hardware operates only in optimal temperatures (up to 2); not available on 4820 and 4835
• SNMP Power Control – Supports use of SNMP set instructions for outlet level control, SNMP traps, Management Information Base (MIB) & Object Identification Tree (OIDTree) available on-line
Server TechnologySolutions for the Data Center Equipment Cabinet
Server TechnologySolutions for the Data Center Equipment Cabinet
Unique Expansion Capability
• Any “master” XLS unit can be linked to an “expansion” XMS unit
• One IP address
• Reduce costs
• Grouping across devices pairs for simultaneous power up of multiple supply devices
• Provides redundant power sources for fail-safe operations
•Eliminates single point of failure (see diagram on slide 16)
How does a Sentry -48VDC Remote Power Manager Support Equipment?
Server TechnologySolutions for the Data Center Equipment Cabinet
This setup supports full redundancy and eliminates single point-of-failure concerns by allowing each Cisco power supply to connect and separate Sentry Remote Manager units.
Each Output Fused at: 40 ACisco Power Supply Output: 4000 W each
H-Tap used on each source to provide power to both input blocks on each Sentry -48 VDC Remote Power Manager.
XLS-to-XMS data link allows 8 switched outputs to be addressed through a single unified interface. All 6 output connections to the Cisco OSR-7609 may be grouped together such that one command controls all power delivered to both 4000 W Cisco power supplies.
Sentry 4870-XLS-4 and 4870-XMS-4 Typical Setup for Cisco OSR-7609 w/Dual 4000W Power Supplies
A
+RTN
GN
D-4
8VD
C
+RTNG
ND
-48VDC
www.servertech.com
F1 F2 F1 F2
B5
AUX
A1- A1+ A2- A2+ B1- B1+ B2- B2+
+-
TELPOW
ER
TPC-40AMPS
Bussmann
TELP
OWER
TPC
-40 AM
PSBu
ssma
nn FUSEFUSE
TELPOW
ER
TPC-40AMPS
Bussmann
TELP
OWER
TPC
-40 AM
PSBu
ssma
nn FUSEFUSE
TELPOWER
TPC-40
AMPS
Bussmann
TELP
OW
ER
TPC-
40 AMPS
Buss
mann FUSE
FUSE
TELPOWER
TPC-40
AMPS
Bussmann
TELP
OW
ER
TPC
-40 AM
PSBu
ssma
nn FUSE
FUSE
+RTN
GN
D-4
8VD
C
+RTN
GN
D-48VD
C
www.servertech.com
F1 F2 F1 F2
B5
AUX
A1- A1+ A2- A2+ B1- B1+ B2- B2+
+-
TELPOWER
TPC-40AM
PSBussmann
TELP
OWER
TPC
-40 AM
PSBu
ssma
nn FUSE
FUSE
TELPOWER
TPC-40AM
PSBussmann
TELP
OWER
TPC-
40 AMPS
Buss
mann FUSE
FUSE
TELPOWER
TPC-40
AMPS
Bussmann
TELP
OW
ER
TPC
-40 AM
PSBu
ssma
nn FUSE
FUSE
TELPOWER
TPC-40
AMPS
Bussmann
TELP
OW
ER
TPC-
40 AMPS
Buss
mann FUSE
FUSE
Power Supply 1 Power Supply 2
9 8 7 6 5 4 3 2 1
FANSTATUS
OSR-7609
+A +
+B
4870-XLS-4 (Master)
-+
G
-+ G
-+
G
-+
-+
G
-+
4870-XMS-4 (Expansion unit)
XLSß
àX
MS
Data Link C
able
4870-XMS-4 Expansion Unit
4870-XLS-4 Master
Secure Web Interface
Server TechnologySolutions for the Data Center Equipment Cabinet
-Fully embedded
-Individual outlet load monitoring
-Outlet Remote Control
-Individual or Grouped
Beginning with Benjamin Franklin, it was traditionally assumed that electricity flows from a positively charged region to a negatively charged region. The discovery of the electron corrected that. Electricity actually flows from a negatively charged region to a positively charged region; electrons move from the negative (-) to the positive (+).
Thusly, the negative (-) is the source, the positive (+) is the return, and the implications with respect to a Sentry -48VDC Remote Power Manager are:
• The negative (-) conductor from each Sentry output to each device must be electrically isolated
• Though not required, the positive (+) return output to each device may be electrically common.
Conversely, a positive (+) direct-current system would require that the positive (+) return to each device be electrically isolated and would allow the negative (-) connection to be common. A simple example of a positive (+) system is the electrical distribution in most automobiles. The negative (-) source of the 12V car battery is connected to the metal frame of the car and is common such that the negative terminal for each device (stereo, headlights, etc.) is easily attached to the frame at any point. The positive (+) terminal for each device is then individually conducted to the positive terminal of the battery. Fuses for each device are located on the individual conductors between each device and the positive terminal of the battery.
Server TechnologySolutions for the Data Center Equipment Cabinet
So why is it called “-48VDC”?
A common question is “can the Sentry -48VDC Remote Power Managers work with a +48VDC system?” The answer is NO.
Server TechnologySolutions for the Data Center Equipment Cabinet
• All Sentry Switched -48VDC Remote Power Managers are engineered for a -48VDC system. Of particular importance is the fact that the relay for each switched output is positioned on the negative terminal; only the negative (-) terminal of each output pair (+/-) is switched on/off. Additionally, both the load-measurement circuit and over-current protection for each device are also positioned on the negative (-) lines.
• The following simple wiring diagram illustrates the typical Sentry power distribution layout. Specifically, this diagram shows the basic distribution layout for one half of a Sentry 4870 unit.
A
+RTN
GN
D-4
8VD
C
A1- A1+ A2- A2+
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC-
50 AMPS
Buss
man
n FUSEFUSE
TELPOW
ER
TPC-50AMPS
Bussmann
TELP
OW
ER
TPC-
50 AMPS
Buss
man
n FUSEFUSE
Fuse A1
Fuse A2
Relay A1, closed
Relay A2, closed
Server TechnologySolutions for the Data Center Equipment Cabinet
Now, we add some loads (light bulbs)and indicate the current flow w/ arrows:
A
+RTN
GN
D-4
8VD
C
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC
-50 AM
PS
Buss
man
n FUSEFUSE
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC
-50 AM
PS
Buss
man
n FUSEFUSE
Fuse A1
Fuse A2
Relay A1, closed
Relay A2, closed
-+ +
· Positive is common within Sentry and can be common across loadsoutside of the Sentry. See areas noted in blue.
Positive (+) can be common at other points
Positive (+) is commonat this point
· This is a negative DC system. Positive (+) can be common.
If a user instructs output A1 to turn off,we see that everything works.
A
+RTN
GN
D-4
8VD
C
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC-
50 AMPS
Buss
man
n FUSEFUSE
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC
-50 AM
PS
Buss
man
n FUSEFUSE
Fuse A1
Fuse A2
Relay A1, closed
Relay A2, closed
-+
· Relay A1 opening interrupts the circuit to the attached device and the device turns off.
+
Server TechnologySolutions for the Data Center Equipment Cabinet
Now, the diagram to the right illustratesa -48VDC Sentry unit connected to loads requiring a positive system(because the negative is common).
A
+RTN
GN
D-4
8VD
C
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC
-50 AM
PS
Buss
man
n FUSEFUSE
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC
-50 AM
PS
Buss
man
n FUSEFUSE
Fuse A1
Fuse A2
Relay A1, closed
Relay A2, closed
-+
· Note that the bulbs now have a common negative indicated by the blue arrows.
Negative (-) is common here
Positive (+) is commonat this point
· Power is successfully delivered, however...
If a user instructs output A1 to turn off,the device does not turn off.
A
+RTN
GN
D-4
8VD
C
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC
-50 AM
PS
Buss
man
n FUSEFUSE
TELPOW
ER
TPC-50AM
PS
Bussmann
TELP
OW
ER
TPC
-50 AM
PS
Buss
man
n FUSEFUSE
Fuse A1
Fuse A2
Relay A1, open
Relay A2, closed
-+
· Relay A1 opens but the attached load continues to receive power from the the alternate path due to the common negative (-).
· Power continues to be delivered and the load increases on the alternate path.
· Similarly, if either fuse opens to clear a fault, the fault will ‘blow’ the other fuse.
Server TechnologySolutions for the Data Center Equipment Cabinet
Agency Approvals
• EN 60950-1• UL 60950-1• CAN/CSA-22.2 No. 60950-103• CB report• cTUVus for NA• TUV-GS for Europe• FCC Class A• CE Mark• NEBS Compliant
Customers using Sentry -48VDC
Server TechnologySolutions for the Data Center Equipment Cabinet
Server TechnologySolutions for the Data Center Equipment Cabinet
The END