38
215-1472 Rev. F; EN 06-915 © 2007 Bradley Corporation Page 1 of 38 2/12/07 P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-Bradley FAX 262-251-5817 http://www.bradleycorp.com Parts & Service Guide Current Models After May 2, 2005 Sentry Washfountain
Transcript
Page 1: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

215-1472 Rev. F; EN 06-915© 2007 Bradley Corporation Page 1 of 38 2/12/07

P.O. Box 309, Menomonee Falls, WI 53052-0309TEL. 1-800-Bradley FAX 262-251-5817http://www.bradleycorp.com

Parts & Service GuideCurrent Models After May 2, 2005

Sentry Washfountain

Page 2: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

2 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Table of ContentsWashfountain Identification Page #

Identification Charts and Model Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3How to Determine Drain Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Sentry™ WashfountainsInfrared (IR) — Sprayhead Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Infrared (IR) Part 1 — Solenoid Valve Assembly (24V transformer) . . . . . . . . . . . . . . . . . . . . . . . .6-9Infrared (IR) Part 2 — Solenoid Valve Components (24V transformer) . . . . . . . . . . . . . . . . . . . . . .10Infrared (IR) — Sensor and Solenoid Valve Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11Infrared (IR) SN2003, SN2023, SN2013, SN2033 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . .12Infrared (IR) SN2004, SN2024 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Infrared (IR) SN2005 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Infrared (IR) SN2008 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Sentry Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Supply Valves — Pressure Balancing Complete Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Air Metering Valve (AST4) — Hand Pushbutton and Sprayhead . . . . . . . . . . . . . . . . . . . . . . . . . . .18Air Metering Valve (AST4-F) — Foot Pushbutton and Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Air Metering Valve (AST4) Part 1 — Assembly and Components . . . . . . . . . . . . . . . . . . . . . . . .20-23Air Metering Valve (AST4) Part 1 — Assembly and Components . . . . . . . . . . . . . . . . . . . . . . . .20-23Air Metering Valve (AST4) Part — Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Air Metering Valve (AST4) Part 2 — Assembly and Components . . . . . . . . . . . . . . . . . . . . . . . . . .25Troubleshooting Air Valve Metering Hand Control (AST4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-28Vernatherm® Thermostatic Mixing Valve Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Vernatherm™ Mixing Valve — TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Cleaning the Strainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29-30Control Valve Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31Check Valve Troubleshooting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Care and Cleaning of Stainless Steel Sentry Washfountains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Sprayhead Cover and Soap System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33-34Pedestal Assembly — Access Panels, Bowl Hardware, Drain Parts . . . . . . . . . . . . . . . . . . . . . . . . .35Backsplash Retrofit Kits — S65-237 for 36" Semi, S65-238 for 54" Semi . . . . . . . . . . . . . . . . . . . .36Shroud/Towel Dispenser — Installed on a Shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Towel Dispenser — Installed on a Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

Page 3: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 3

Stainless Steel – Infrared, Hand or Foot Operated• Reliable Pushbutton Activated Air Metering or

Infrared Control• Available in a 54" or 36" Bowl Size• Standard Height 54" Model with Hand or Infrared

Control is ADA Compliant• Factory Tested and Shipped Preassembled• Vandal Resistant and Easy to Clean

Models Available:SN2003 36" Semi-Circular – Floor-MountedSN2004 54" Semi-Circular – Floor-MountedSN2023 36" Semi-Circular – Wall-MountedSN2024 54" Semi-Circular – Wall-MountedSN2005 36" Circular – Floor-MountedSN2008 54" Circular – Floor-MountedSN2013 54" Corner – Floor-MountedSN2033 54" Corner – Wall-Mounted

Sentry Washfountain Products

SN2008/AST

SN2008/IR

SN2008/AST-F

SN2013/IR

SN2013/AST-F

SN2033/IR

SN2013/AST

SN2004/AST

SN2004/IR

SN2004/AST-F

2/12/07

Page 4: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

4 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

How to Determine Drain Type(Parts may vary depending upon drain type. Identify your drain type before continuing.)

TYPE A:SUPPLIES BELOW,VENT OFF DRAIN.P-TRAP FURNISHED BY OTHERS.

TYPE B:SUPPLIES ABOVE,CENTRALLY-RISING VENT.P-TRAP FURNISHED.

TYPE H:SUPPLIES BELOW,CENTRALLY-RISING VENT.P-TRAP FURNISHED.

TYPE O:SUPPLIES ABOVE,VENT OFF DRAIN.P-TRAP FURNISHED BY OTHERS.

Page 5: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 52/12/07

Infrared (IR) — Sprayhead Assembly

8

6

7

34

5 9

1

2

10

11

12

Parts List — Infrared Sensor and Module

1 — Shell 1 1 1 1 12 269-982 Lens (window) 3 3 4 5 83 160-245 Screw 10-24 x 1/2" 6 6 8 10 164 142-002BT Lock Washer 6 6 8 10 165 142-002AV Flat washer 6 6 8 10 166 269-1184 Sensor 3 3 4 5 87 182-100 Lens Support (Rubber Block) 3 3 4 5 88 159-363 Sensor Mounting Bracket 3 3 4 5 89 161-082 Nut - Extension 1/4"-20 x 5-1/8" 2 2 2 2 2

10 269-621 Terminal - female disconnect 9 9 12 15 2411 S05-157 Aerator Assembly (Std 0.5 GPM) 3 3 4 5 812 110-115 Nut - 1/2" - 14 3 3 4 5 8

54" Corner 36" Semi 54" Semi 36" Circle 54" CircleItem Part No. Description Qty Qty Qty Qty Qty

Parts List — Aerator Assembly

1

23

4

* Spanner wrench not included in Assemblies

S05-157Item Part No. Description Qty

1 S05-142A Std. Aerator, 0.5 GPM 12 153-402A Adapter 13 145-090 90° Connector 1/4" tube x 1/8" NPT 1

* 4 130-141 Spanner Wrench for Aerator —

Page 6: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

6 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Infrared (IR) Part 1 — Solenoid Valve Assembly (24V Transformer)

5

6

1

2

3

4

910

12 1311

7

14

8

* Specify length in feet.

1 S27-102 STOP/CHECK VALVE 2 22 269-1735 FLEX HOSE 2 23 140-928 BRACKET 1 14 269-625 TERMINAL BLOCK 1 15 P18-054 SCREW #10-24 X 3/8 2 26 160-447 SCREW #8-16 X 5/8 3 37 S01-524 THERMOSTATIC MIXING VALVE 1 18 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 1 19 S07-067 SOLENOID VALVE - CLOSED BODY (BLACK) 1 1

10 S07-067A SOLENOID VALVE -THRU BODY (GRAY) 2 211 R68-600011-B TUBING 1/4 OD BLACK * *12 R68-600011-G TUBING 1/4 OD GREEN * *13 R68-600011-R TUBING 1/4 OD RED * *14 S45-2146 VALVE ASSY TMA 36S & 54K 1 1

54" Corner 36" SemiItem Part No. Description Qty

Parts List — Solenoid Valve Assembly

Page 7: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 72/12/07

Infrared (IR) Part 1 — Solenoid Valve Assembly (24V Transformer)

6

39

10

4

5

1

2

14131211

7

15

8

1 S27-102 STOP/CHECK VALVE 22 269-1735 FLEX HOSE 23 140-928 BRACKET 14 269-647 TERMINAL BLOCK 15 P18-054 SCREW #10-24 X 3/8 26 160-447 SCREW #8-16 X 5/8 47 S01-524 THERMOSTATIC MIXING VALVE 18 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 19 S07-067 SOLENOID VALVE - CLOSED BODY (BLACK) 1

10 S07-067A SOLENOID VALVE-THRU BODY (GRAY) 311 R68-600011-Y TUBING 1/4 OD YELLOW *12 R68-600011-B TUBING 1/4 OD BLACK *13 R68-600011-G TUBING 1/4 OD GREEN *14 R68-600011-R TUBING 1/4 OD RED *15 S45-2148 VALVE ASSY TMA 54S 1

Item Part No. Description Qty

Parts List — Solenoid Valve Assembly — 54" Semi

* Specify length in feet.

Page 8: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

8 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Infrared (IR) Part 1 — Solenoid Valve Assembly (24V Transformer)

1

2

4

5

6

7

9

10

3

1514131211

16

8

* Specify length in feet.

1 S27-102 STOP/CHECK VALVE 22 269-1735 FLEX HOSE 23 140-940 BRACKET 14 269-625 TERMINAL BLOCK 25 P18-054 SCREW #10-24 X 3/8 26 160-447 SCREW #8-16 X 5/8 57 S01-524 THERMOSTATIC MIXING VALVE 18 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 19 S07-067 SOLENOID VALVE - CLOSED BODY (BLACK) 1

10 S07-067A SOLENOID VALVE - THRU BODY (GRAY) 411 R68-600011-Y TUBING 1/4 OD YELLOW *12 R68-600011-B TUBING 1/4 OD BLACK *13 R68-600011-G TUBING 1/4 OD GREEN *14 R68-600011-R TUBING 1/4 OD RED *15 R68-600011 TUBING 1/4 OD CLEAR *16 S45-2150 VALVE ASSY TMA/IR 36C 1

Item Part No. Description Qty

Parts List — Solenoid Valve Assembly — 36" Circle

Page 9: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 92/12/07

Infrared (IR) Part 1 — Solenoid Valve Assembly (24V Transformer)

1

2

3

56

7

9

10

4

1414 1313 1212 1111

15

8

* Specify length in feet.

1 S27-102 STOP/CHECK VALVE 22 269-1735 FLEX HOSE 23 140-941 BRACKET 14 269-647 TERMINAL BLOCK 25 P18-054 SCREW #10-24 X 3/8 26 160-447 SCREW #8-16 X 5/8 87 S01-524 THERMOSTATIC MIXING VALVE 18 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 19 S07-067 SOLENOID VALVE - CLOSED BODY (BLACK) 1

10 S07-067A SOLENOID VALVE -THRU BODY (GRAY) 711 R68-600011-Y TUBING 1/4 OD YELLOW *12 R68-600011-B TUBING 1/4 OD BLACK *13 R68-600011-G TUBING 1/4 OD GREEN *14 R68-600011-R TUBING 1/4 OD RED *15 S45-2152 VALVE ASSY TMA/IR 54C 1

Item Part No. Description Qty

Parts List — Solenoid Valve Assembly — 54" Circle

Page 10: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

10 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Infrared (IR) Part 2 — Solenoid Valve Assembly (24V Transformer)

7

5

9

8

1

2

10

11

3

6

OR4

1312 OR

1 110-231 NUT 1/4 TUBE 12 118-307 VALVE BODY 1/4" CLOSED 13 118-307A VALVE BODY 1/4" THRU 14 125-165 O-RING 15 269-983 DIAPHRAGM 16 269-577 ARMATURE 17 269-578 SPRING 18 269-1729 ARMATURE HOUSING 19 269-1730 CLAMP 1

10 160-447 SCREW #8-16 X 5/8 311 269-579 COIL, SOLENOID VALVE 112 S07-067 SOLENOID VALVE CLOSED BODY 113 S07-067A SOLENOID VALVE THRU BODY 1

Item Part No. Description Qty

Parts List — Solenoid Valve Assembly

Page 11: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 112/12/07

Infrared (IR) — Sensor and Solenoid Valve Troubleshooting

If a station is not functioning properly it is most likely either the solenoid valve or the sensor.Troubleshooting multi station units is fairly easy, as you can swap parts (actually just by changing the wires)and use the process of elimination to figure out which of the 2 parts is causing the problem.

How the system operates:1. The transformer sends 24 volts to the sensor. 2. The sensor acts only as a switch. 3. When hands go into the active field of the sensor, the sensor activates and sends a power signal

on to the solenoid valve.4. The power signal activates and opens the solenoid valve which allows the water to flow to the

sprayhead. The solenoid valve stays open allowing water to flow as long as it is receiving a signal form the sensor (hands remain in the active field).

5. When hands are removed from the active field, the sensor turns off (note some models have a slight delay feature built-in.) and shuts off the power signal to the solenoid valve.

CAUTION: Turn off water supplies to unit before troubleshooting.Problem: An individual operating station fails to shut off and drips.Cause: There is debris trapped between the diaphragm and the valve seat.Solution: Remove debris between diaphragm and the valve seat.

1. Remove the three #8 Phillips-head screws that hold the solenoid valve assembly together. Becareful not to lose the armature or spring.

2. Remove the diaphragm. Remove any particles that have been trapped between the diaphragmand the valve seat. Rinse off the diaphragm and inspect for damage. Make sure the center ori-fice and both small side orifices are open.

3. Reassemble in reverse order, being careful not to overtighten the Phillips-head screws or youmay crack the plastic valve body. Tighten until the armature plate makes contact with the plasticbody.

4. Reconnect the wiring per the appropriate diagram on next 4 pages.Problem: An individual operating station fails to turn on.Cause: A failed coil for the valve or loose electrical connection to the terminal.Solution: Test the station to determine cause.1. Disconnect the wires from the coil of an adjacent valve. Disconnect the wires from the problem

valve and reconnect to the adjacent valve.2. Turn on electrical and water supplies to the unit. Pass your hand in front of the sensor of the

problem station, and the adjacent station should turn on. If the adjacent station turns on and cycles normally, replace the coil on the problem valve.If the adjacent valve fails to turn on, inspect the wires from the sensor cable and do the following:• make sure there are no breaks and that the fully insulated disconnect terminals are firmly

crimped in place;• turn off the electrical and water supplies;• reconnect to the adjacent valve and turn on the water supplies to the unit;• pass your hand in front of the sensor. If the station still fails to turn on, replace the sensor.

Page 12: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

12 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Supply Inlets

Vernatherm™ TMV

Solenoid Valve Assembly

Black

Blue

Red

24 VAC from transformer– 18 Gauge wires by

customer to transformerscrew terminals

To sensorsin sprayhead

Solenoid Tube ConnectorCompression Nut

Infrared (IR) SN2003, SN2023, SN2013, SN2033 Wiring Diagram

Page 13: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 132/12/07

Infrared (IR) SN2004, SN2024 Wiring Diagram

Supply Inlets

Vernatherm™ TMV

Solenoid Valve Assembly

Black

Blue

Red

24 VAC from transformer– 18 Gauge wires by

customer to transformerscrew terminals

To sensorsin sprayhead

Solenoid Tube ConnectorCompression Nut

Page 14: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

14 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Infrared (IR) SN2005 Wiring Diagram

Supply Inlets

Vernatherm™ TMV

Solenoid Valve Assembly

24 VAC from transformer– 18 Gauge wires by

customer to transformerscrew terminals

Solenoid Tube Connector

Compression Nut

Page 15: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 152/12/07

Infrared (IR) SN2008 Wiring Diagram

Supply Inlets

Vernatherm™ TMV

Solenoid Valve Assembly

24 VAC from transformer– 18 Gauge wires by

customer to transformerscrew terminals

Solenoid Tube Connector

Compression Nut

Page 16: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

16 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

SN2003 36" Semi-Circular – Floor Mounted S45-2045 1 269-645 1SN2004 54" Semi-Circular – Floor Mounted S45-2045 1 269-645 1SN2023 36" Semi-Circular – Wall Mounted S45-2045 1 269-645 1SN2024 54" Semi-Circular – Wall Mounted S45-2045 1 269-645 1SN2005 36" Circular – Floor Mounted S45-2045 2 * 269-703 1SN2008 54" Circular – Floor Mounted S45-2045 2 * 269-703 1SN2013 54" Corner – Floor Mounted S45-2045 1 269-645 1SN2033 54" Corner – Wall Mounted S45-2045 1 269-645 1

Model Description Current Part Number Prior to May 2003Qty Qty

* Available for service.

Sentry Transformers

Page 17: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 172/12/07

Supply Valves — Pressure Balancing Complete Assembly

2

4

1

6

5

73

PBV —Pressure BalancingComplete Assy. as Shown - S67-516

Parts List — Supply Valve S67-516

1 169-168 PIPE PLUG 12 S67-594 PBV VALVE 13 128-032 HANDLE FOR VALVE 14 160-214 SCREW FOR HANDLE 15 113-339 NIPPLE – 1/2" 16 169-639 ELBOW 27 269-1735 STAINLESS STEEL FLEX HOSE 1

Item Part No. Description Qty

Page 18: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

18 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Parts List — Pushbutton

1 — Shell 1 1 1 1 12 S08-324 Pushbutton Assy. (includes items 3 thru 5) 3 3 4 5 83 128-090 Pushbutton Only 3 3 4 5 84 179-102 Guide for pushbutton 3 3 4 5 85 147-033 Screw for pushbutton 3 3 4 5 86 140-743 Bracket - Actuator 3 3 4 5 87 110-115 Nut 1/2"-14 3 3 4 5 88 169-890 Connector 1/8" tube x 10-32 Thd. 3 3 4 5 89 269-1186 "L" Fitting Adjustable 3 3 4 5 810 118-279 Actuator Body 3 3 4 5 811 135-065 Spring 3 3 4 5 812 125-099 U-Cup for piston 3 3 4 5 813 119-227A Piston 3 3 4 5 814 198-010 Duckbill 3 3 4 5 815 160-165 Screw - Body mounting 6 6 8 10 1616 R68-600008 Tubing 1/8" OD (specify length in feet) — — — — —

* 17 S05-157 Aerator Assembly (Std 0.5 GPM) 3 3 4 5 819 161-082 Nut - Extension 1/4"-20 x 5-1/8" 2 2 2 2 220 130-141 Spanner Wrench for Aerators 1 1 1 1 121 130-023 Spanner Wrench for Pushbuttons 1 1 1 1 1

54" Corner 36" Semi 54" Semi 36" Circle 54" CircleItem Part No. Description Qty Qty Qty Qty Qty

Air Metering Valve (AST4) — Hand Pushbutton and Sprayhead

7

8

9

17

2

15

10

11 1213

23

45

6

14

21

177

19

16

20

Prepack S65-168A* See following page for additional information.

Pushbutton ReplacementIMPORTANT: Turn off water

supplies beforereplacing thepushbutton.

1. Remove the sprayhead cover by removingthe two screws holding the cover to thesprayhead module.

2. Inside sprayhead, unscrew the two screwsthat hold the actuator body to the bracketbeing careful of the spring that will release.

3. Unscrew and remove the coupling if neces-sary.

4. Unscrew and remove the brass nut if neces-sary. This will allow the pushbutton assem-bly to be removed.

5. Carefully take apart the assembly andreplace the parts as needed.

6. After replacement is complete, reassemblethe pushbutton and sprayhead as shown.

Page 19: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 192/12/07

Air Metering Valve (AST4-F) — Foot Pushbutton and Actuator

Parts List — Pushbutton & Actuator Assy.

Parts List — S08-288Actuator Assy.

1 S08-288 1 Actuator Assy.2 140-604 1 Bracket3 150-198 1 Escutcheon4 128-090 1 Pushbutton5 179-071 1 Pushbutton Guide6 110-115 1 Nut 1/2"-147 119-132 1 Plunger8 160-245 2 Screw for escutcheon

Item Part No. Qty Description

1 160-276 4 Screw 8-32 x ¾"2 140-493 1 Mounting Plate3 269-612 1 Diaphragm4 269-613 1 Back Plate5 161-062 4 Nut 8-326 142-002CR 4 Washer #8 lock7 125-001CZ 1 O-Ring8 169-890 1 Fitting - tube connector 10-32 x 1/8"

Item Part No. Qty Description

45

7 2

36

1

8

Foot Button Assembly S45-1543

1

6

7

8

5

2

4

3

Actuator Assembly S08-288

1

23

4

Parts List — Aerator Assembly

* Spanner wrench not included in Assemblies

S05-157Item Part No. Description Qty

1 S05-142A Std. Aerator, 0.5 GPM 12 153-402A Adapter 13 145-090 90° Connector 1/4" tube x 1/8" NPT 1

* 4 130-141 Spanner Wrench for Aerator —

Page 20: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

20 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Air Metering Valve (AST4) Part 1 — Assembly and Components

5

6

9

1

2

3

4

8

14

10 11 12

13 1516

7

* Specify length in feet.

1 S27-102 STOP/CHECK VALVE 2 22 269-1735 FLEX HOSE 2 23 140-928 BRACKET 1 14 P18-054 SCREW #10-24 X 3/8 2 25 160-447 SCREW #8-16 X 5/8 3 36 S01-524 THERMOSTATIC MIXING VALVE 1 17 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 1 18 S07-077A AST4 VALVE, THROUGH BODY (GRAY) 2 29 S07-077 AST4 VALVE, CLOSED BODY (BLACK) 1 1

10 R68-600011-B TUBING 1/4 OD BLACK * *11 R68-600011-G TUBING 1/4 OD GREEN * *12 R68-600011-R TUBING 1/4 OD RED * *13 R68-00008-B TUBING 1/8 OD BLACK * *14 R68-00008-G TUBING 1/8 OD GREEN * *15 R68-00008-R TUBING 1/8 OD RED * *16 S08-443TMA VALVE ASSY AST 1 1

54" Corner 36" SemiItem Part No. Description Qty

Parts List — Air Metering Valve Assembly

Page 21: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 212/12/07

Air Metering Valve (AST4) Part 1 — Assembly and Components

1716

1514

13121110

9

8

5

4

3

2

1

6

18

7

1 S27-102 STOP/CHECK VALVE 22 269-1735 FLEX HOSE 23 140-928 BRACKET 14 P18-054 SCREW #10-24 X 3/8 25 160-447 SCREW #8-16 X 5/8 46 S01-524 THERMOSTATIC MIXING VALVE 17 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 18 S07-077A AST4 VALVE, THROUGH BODY (GRAY) 39 S07-077 AST4 VALVE, CLOSED BODY (BLACK) 1

10 R68-600011-Y TUBING 1/4 OD YELLOW *11 R68-600011-B TUBING 1/4 OD BLACK *12 R68-600011-G TUBING 1/4 OD GREEN *13 R68-600011-R TUBING 1/4 OD RED *14 R68-600008-Y TUBING 1/8 OD YELLOW *15 R68-00008-B TUBING 1/8 OD BLACK *16 R68-00008-G TUBING 1/8 OD GREEN *17 R68-00008-R TUBING 1/8 OD RED *18 S08-444TMA VALVE ASSY AST4 1

Item Part No. Description Qty

Parts List — Air Metering Valve Assembly — 54" Semi

* Specify length in feet.

Page 22: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

22 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Air Metering Valve (AST4) Part 1 — Assembly and Components

1

2

3

4

5

6 8

9

1918

1716

15

1413121110

20

7

1 S27-102 STOP/CHECK VALVE 22 269-1735 FLEX HOSE 23 140-940 BRACKET 14 P18-054 SCREW #10-24 X 3/8 25 160-447 SCREW #8-16 X 5/8 56 S01-524 THERMOSTATIC MIXING VALVE 17 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 18 S07-077A AST4VALVE,THROUGH BODY (GRAY) 49 S07-077 AST4 VALVE, CLOSED BODY (BLACK) 1

10 R68-600011-Y TUBING 1/4 OD YELLOW *11 R68-600011-B TUBING 1/4 DD BLACK *12 R68-600011-G TUBING 1/4 OD GREEN *13 R68-600011-R TUBING 1/4 OD RED *14 R68-600011 TUBING 1/4 OD CLEAR *15 R68-00008-Y TUBING 1/8 OD YELLOW *16 R68-00008-B TUBING 1/8OD BLACK *17 R68-00008-G TUBING 1/8 OD GREEN *18 R68-00008-R TUBING 1/8 OD RED *19 R68-00008 TUBING 1/8 OD CLEAR *20 S08-445TMA VALVE ASSY, AST 1

Item Part No. Description Qty

Parts List — Air Metering Valve Assembly — 36" Circle

* Specify length in feet.

Page 23: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 232/12/07

Air Metering Valve (AST4) Part 1 — Assembly and Components

1

2

3

4

5

6 8

9

17

17

16

16

15

15

14

14

13 131212 1111 1010

18

7

1 S27-102 STOP/CHECK VALVE 22 269-1735 FLEX HOSE 23 140-941 BRACKET 14 P18-054 SCREW #10-24 X 3/8 25 160-447 SCREW #8-16 X 5/8 86 S01-524 THERMOSTATIC MIXING VALVE 17 S39-685 ADAPTER (OPTIONAL SINGLE TEMPERED LINE) 18 S07-077A AST4 VALVE, THROUGH BODY (GRAY) 79 S07-077 AST4 VALVE, CLOSED BODY (BLACK) 1

10 R68-00011-Y TUBING 1/4 OD YELLOW *11 R68-600011-B TUBING 1/4 OD BLACK *12 R68-600011-G TUBING 1/4 OD GREEN *13 R68-600011-R TUBING 1/4 OD RED *14 R68-00008-Y TUBING 1/8 OD YELLOW *15 R68-00008-B TUBING 1/8 OD BLACK *16 R68-00008-G TUBING 1/8 OD GREEN *17 R68-00008-R TUBING 1/8 OD RED *18 S08-448TMA VALVE ASSY, AST4 1

Item Part No. Description Qty

Parts List — Air Metering Valve Assembly — 54" Circle

* Specify length in feet.

Page 24: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

24 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Air Metering Valve (AST4) Part 1 — AdjustmentAdjusting Air Metering Valve (Hand-operated pushbutton only)

NOTE: The air valve timer is located next to the tube connector on the air valve body. The timer iscapped with a filter to prevent dirt build-up on the timer. The air valve timing can be adjusting from0–45 seconds.

1. Adjust the metering timing, if necessary, as outlined below:• Unscrew the timer cover and use a screwdriver to tighten or loosen the timer. Turning the

timer clockwise increases the time; turning the timer counterclockwise decreases the time. Becareful not to overtighten as the timer seat can be damaged.

• Continue to adjust until the timer is set at desired length.• Replace the timer cover over the timer.

TIMER ASSEMBLY TIMER COVER

Page 25: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 252/12/07

1 Diaphragm 1 — 1 1 —2 Armature 1 — 1 1 —3 Spring 1 — 1 1 —4 AST 4 Valve Upper Body 1 — — 1 —5 Magnet / Diaghragm Assembly 1 1 — 1 16 AST 4 Valve Cover 1 1 — — —7 AST 4 Valve Clamp Nut 1 1 — 1 18 AST 4 Valve Timer Assembly 1 — — — —9 O-Ring, (-012) 1 — — — —

10 AST 4 Valve Timer Cover 1 — — — —11 Screw, #8 x 7/8" 3 — — 3 —12 Compression Nut, 1/8" Tube 1 1 — — —13 AST 4 Valve Cover Foot — — — 1 114 Tube Connector — — — 1 115 Compression Spring, AST 4 1 1 — 1 1

AST 4 Repair Kit Repair Kit AST 4 Repair Kit FootValve (Upper) (Lower) Foot Valve (Upper)

S65-260 S65-261 S65-262 S65-280 S65-281

Item Description Qty

AST4 Valve Parts List

7

8

10

6

5

1512

3

4

11

2

1

9

S65-261

S65-262

7

14

13

5

15

3

4

11

2

1

S65-281

S65-262

AST 4S65-260

AST 4 Foot ValveS65-280

Air Metering Valve (AST4) Part 2 — Assembly and Components

Page 26: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

26 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Troubleshooting Air Valve Metering Hand Control (AST4)CAUTION: Turn off water supplies to unit before troubleshooting.

Problem: One or more individual operating stations fail to turn on.Cause: Incoming water pressure is over 80 PSIG.Solution: Reduce water pressure to below 80 PSIG.

Install a pressure-reducing valve at the building main set to the manufacturer's recommendations.Lower line pressure will improve the performance and extend the life of all the plumbing in thebuilding.

Problem: An individual operating station fails to turn on.Cause: A failed diaphragm/magnet assembly.Solution: Test the station to determine cause.

1. Unscrew the valve clamp nut on the top of the valve (see Page 25).2. Remove valve cover. If the diaphragm/magnet assembly comes out with the cover, gently peel

the diaphragm away form the cover, taking care not to damage the diaphragm. Inspect thediaphragm for any holes of tears. A damaged diaphragm needs to be replaced.

3. Insert the diaphragm/magnet assembly back into the valve, but leave the cover off.4. Gently press the diaphragm until it is fully depressed. The valve should activate. If not, the

diaphragm/magnet assembly needs to be replaced.

Problem: One or more individual operating stations turn off too quickly or run too long.Cause: Timing requires adjustment.Solution: Readjust timing (see Page 24).

Problem: An individual operating station cannot be adjusted to run for more than five seconds.

Cause: Air tube connection leak.Solution: Check 1/8" tubing connection.

1. Tighten compression nut at 1/8" tubing connection to air valve in pedestal.2. If leak persists, remove the sprayhead cover and check the 1/8" elbow tube connection behind

the pushbutton assembly. Make sure the screw holding the elbow is tight and the fitting in theelbow is firmly hand tightened. Make sure the tubing is pushed firmly into the fitting.

3. If leak persists, reseat the 1/8" tubing. Disconnect the tubing from the fitting by pressing downon the plastic ring at the top of the fitting while firmly pulling the tubing out of the fitting. Trim½" off the end of the tubing squarely with a razor-sharp knife and push the tubing firmly backinto the connector to make sure it is seated.

4. If the leak still persists, loosen the compression nut on the air valve inside the pedestal and pullthe tubing out of the fitting. Trim ½" off the end of the tubing squarely, with a razor-sharp knife.Then slide the tubing through the nut until ½" of tubing is exposed. Insert tubing into the com-pression fitting on the valve body and hand tighten the compression nut.

Page 27: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 272/12/07

Troubleshooting Air Valve Metering Hand Control (AST4) ....Continued

Problem: An individual operating station won't turn off and drips.Cause: There is debris trapped between the diaphragm and valve seat.Solution: Remove debris between the diaphragm and valve seat.

1. Remove the three Phillips-head screws that hold the air valve together. Be careful not to lose thearmature or spring (see Page 25).

2. Remove the diaphragm. Remove any debris trapped between the diaphragm and the valve seat.3. Rinse off the diaphragm and inspect for damage. Make sure the center orifice and the two small

side orifices are open.4. Reassemble in reverse order, being careful not to over tightening the Phillips-head screws or you

may crack the plastic valve body. Tighten until the armature plate makes contact with the plasticbody.

Problem: An individual station will not shut off.Cause: Timing mechanism is clogged.Solution: Clear the timing mechanism.

1. If the timer cover has been sprayed with water, wait at least two minutes. It will shut off andreturn to normal operation once it dries off.

2. If it doesn't turn off remove the timer cover. If the valve shuts off the cover is clogged andneeds to be replaced.

3. If the valve still doesn't turn off, turn the adjusting screw counter clockwise until it can beremoved from the valve body.

4. Wipe adjusting screw thoroughly with a lint-free towel making sure that there is no water ordebris on the adjusting screw.

5. Use a pipe stem cleaner to wipe the inside of the timer body if possible.6. Replace timer-screw and adjust valve timing.7. Replace timer cover.

Page 28: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

28 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Troubleshooting Air Valve Hold-Open Foot Control (AST4-F)Problem: One or more individual operating stations fail to turn on.Cause: Incoming water pressure is over 80 PSIG.Solution: Reduce water pressure to below 80 PSIG.

Install a pressure-reducing valve at the building main set to the manufacturer's recommendations.Lower line pressure will improve the performance and extend the life of all the plumbing in the build-ing.

Problem: An individual operating station turns off while the foot button is depressed.Cause: Air tube connection leak.Solution: Check 1/8" tubing connection.1. Tighten compression nut at 1/8" tubing connection to air valve in pedestal.2. If leak persists, remove the two screws securing the foot button escutcheon and check the 1/8"

elbow tube connection behind the pushbutton assembly. Make sure the screw holding the elbowis tight and the fitting in the elbow is firmly hand tightened. Make sure the tubing is pushedfirmly into the fitting.

3. If leak persists, reseat the 1/8" tubing. Disconnect the tubing from the fitting by pressing downon the plastic ring at the top of the fitting while firmly pulling the tubing out of the fitting. Trim½" off the end of the tubing squarely with a razor-sharp knife and push the tubing firmly backinto the connector to make it is seated.

4. If the leak still persists, loosen the compression nut on the air valve inside the pedestal and pullthe tubing out of the fitting. Trim ½" off the end of the tubing squarely, with a razor-sharp knife.Then slide the tubing through the nut until ½" of tubing is exposed. Insert tubing into the com-pression fitting on the valve body and hand tighten the compression nut.

Problem: An individual operating station fails to turn on.Cause: A failed diaphragm/magnet assembly.Solution: Test the station to determine cause.

1. Unscrew the valve clamp nut on the top of the valve. (See Page 25).2. Remove valve cover. If the diaphragm/magnet assembly comes out with the cover, gently peel

the diaphragm away form the cover, taking care not to damage the diaphragm. Inspect thediaphragm for any holes of tears. A damaged diaphragm needs to be replaced.

3. Insert the diaphragm/magnet assembly back into the valve, but leave the cover off.4. Gently press the diaphragm until it is fully depressed. The valve should activate. If not, the

diaphragm/magnet assembly needs to be replaced.

Page 29: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 292/12/07

Vernatherm™ Thermostatic Mixing Valve TroubleshootingNOTE: Before attempting to troubleshoot the valve or disassemble the components, check for the fol-lowing conditions:

• If stop/check valves are used, make sure that they are fully open.• Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-

connections or leaking stop/check valves.• Check the hot water heater output to make sure that it is at least 20° F above the set tempera-

ture.Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen thevalves after inspection and repair is complete.

Problem: Limited water flowCause: Dirt and debris have built up in the valve or strainer.

1. Remove and clean strainer (see Figures on next page). If strainer needs to be replaced, orderBradley part no. 173-028.

2. Check the piston for smooth movement.To check the valve's piston for free and smooth movement, follow the procedures outlined below:

1. Remove the valve's cap and thermostat (see next Page ).2. Push down on the piston with your finger (the piston should move freely). If the movement is

not as it should be, the piston needs to be cleaned. Follow the method outlined below for clean-ing the piston and valve body:• Remove the thermostat.• Lift the piston out with a needle-nose pliers and remove the spring.• Any cleaner suitable for brass and stainless steel may be used (if cleaning with suitable cleaner

is not sufficient to remove debris, a 400-grit sandpaper may be used to polish and hone the pis-ton and valve body).

• Snap spring into piston (will detent) and reassemble into the valve body. Retest the piston.3. If, after a thorough cleaning, the piston does not move freely, the piston must be replaced.

Contact your Bradley representative and ask for Repair Kit (part number S65-259).

Problem: External leaks in the systemCause: O-rings have been damaged.

Solution: Replace O-rings where necessary. For replacement of the O-rings, contact your Bradley representative and ask for Repair Kit (part number S65-259).

Problem: Improper water temperature or temperature fluctuationCause: Thermostat is slowly failing or not working at all.

Solution: Check the thermostat for proper operation.1. At room temperature (80° F or less) remove cap and thermostat.2. Place thermostat into container with 115° F water. The pushrod should pop out of the

thermostat approximately 1/10".3. If thermostat pushrod does not pop out, the thermostat must be replaced. Contact your Bradley

representative and ask for Repair Kit (part number S65-259).Cause: Valve temperature is not properly set.

Solution: Adjust the temperature. Using a blade screwdriver, turn the adjustment stem counterclock-wise to increase the temperature or clockwise to decrease the temperature.

Page 30: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

30 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

1

3

4

5

68

9

10

13

7

11

12

2

1 118-315 VALVE BODY 12 119-250 SEAL CUP 13 135-091 SPRING 14 119-243 PISTON 15 S39-413 THERMOSTAT 16 120-153 STEM 17 125-001BX O-RING 18 125-157 O-RING 19 107-522 COVER 1

10 161-157 NUT 3/8-24 111 173-028 STRAINER 212 S65-259 REPAIR KIT VERNATHERM 113 S01-524 THERMOSTATIC MIXING VALVE 1

Item Part No. Description Qty

Parts List — TMA Valve Assembly

Vernatherm™ Mixing Valve

Strainer173-028

Tempered Line Adapter Assembly (S39-685) Option

Page 31: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 312/12/07

Control Valve Illustrations

SPRAYHEADAERATOR

1/8" O.D.CONTROLTUBE

HAND CONTROL ONLY

1/4" O.D.SUPPLYTUBE

AIR VALVEPUSH BUTTON

FOOT PUSHBUTTON

FOOT CONTROL ONLY

AERATOR

1/8" O.D.CONTROL TUBE

1/4" O.D.SUPPLY TUBE

AIR VALVE

Page 32: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

32 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Check Valve Troubleshooting InstructionsIf water just dribbles or does not flow from sprayhead:

1. Close stop/check valves that supply water to the washfountain.2 Inspect stop/check valves for proper installation.3. Remove flexible hoses at stop/check valves and clean the strainers if necessary.

If water sprayhead delivers all hot or cold water:1. Close stop/check valves that supply water to the washfountain.2. Inspect stop/check valves for proper installation.3. Remove flexible hoses at stop/check valves and clean the strainers if necessary.4. Inspect mixing valve for proper installation.

• Hot inlet is marked with an”H”.

Care and Cleaning of Stainless Steel Sentry WashfountainsStainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particu-larly under corrosive conditions, is essential. Follow the cleaning instructions listed below:

• Ordinary deposits of dirt and grease are quickly removed with soap and water. Whenever pos-sible, the metal should be thoroughly rinsed and dried after washing. To remove tightly adher-ing deposits, use stainless steel polishing powder. In all cases, rub in the direction of the stain-less steel grain.

IMPORTANT: Never use ordinary steel wool or steel brushes on stainless steel. Always usestainless steel wool or stainless steel brushes.

• Avoid prolonged contact with chlorides, bromides, thiocyanates, and iodides on stainless steelequipment, especially if acid conditions exist.

• Do not permit salty solutions to evaporate and dry on stainless steel.• The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is

rusting. Look for the actual source of the rust in some iron or steel particles which may betouching, but not actually a part of the stainless steel structure. NOTE: Strongly acidic orcaustic cleaners may attack the steel causing a reddish film to appear. The use of these clean-ers should be avoided.

Page 33: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 332/12/07

Sprayhead Cover and Soap System

2

1

3

4

Soap Valve

5

2

36

8

8

9

7

1 160-154 2 Screw for cover2 — 1 Cover - Call for part number3 133-134 1 or 2 Tank (1 per semi, 2 per circle)4 161-082 2 Nut - Extension 1/4"-20 x 5-1/8" for cover* 153-330 2 or 4 Plug Button - to plug soap valve holes

Item Part No. Qty Description

Parts List — Soap Valve S09-007

1 S09-007 1 Soap Valve - Valve only (Items 2-6)1 S09-007S 1 Soap Valve - Valve w/ Attaching Hardware (Items 2-9)2 118-025 1 Valve Body3 110-007 1 Packing Nut4 135-001L 1 Spring5 125-001BU 1 Washer - Rubber6 119-028 1 Plunger7 161-014 1 Nut8 124-001BV 2 Washer - Fiber9 142-002AH 1 Washer - Stainless Steel

Item Part No. Qty Description

This soap valve delivers soap with eachupward stroke. This soap valve is notsuited for lotion soaps.

NOTE: Lotion soap will clog liquid soapvalves.

* Not Illustrated.

Page 34: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

34 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

SOAP RECOMMENDATIONSQuality soap dispensers require good quality soap and periodic maintenance to properly operate. Bradley soapdispensers will provide dependable, consistent operation over the long term when soap with reasonable viscos-ity and pH levels are used and when a minimal amount of periodic maintenance is performed on the valves.Soap thickness is determined by a measurement called viscosity. Soap viscosity should be between 100 cps(centerpoise) and 2500 cps for all Bradley soap dispensers. Thinner soaps are perceived by the users as being"watered down" so users tend to take more than they need, resulting in waste. Thick soaps flow slower andinhibit the "flushing" action of the valves, which allows the soap to congeal in the valve and cause clogs.The pH (acid) level of the soap should be in the range of 6.5 to 8.5. More acidic soaps (pH levels lower than6.5) will corrode metal parts (even stainless steel!!) and degrade rubber and plastic components. They will alsocause skin irritation. Most inexpensive soaps (typically the pink lotion type) fall into this acidic category andwill eventually cause valve failure and metal corrosion. Base soaps (pH levels higher than 8.5) will causeswelling or degradation of rubber and plastic parts and skin irritation.Generally, any quality soap meeting the viscosity and pH guidelines above will work well with Bradley soapdispensers. PCMX or Isapropanol based antibacterial soaps (within viscosity and pH limits) will also workwith Bradley dispensers. Soaps satisfying these basic guidelines will provide consistent flow and reduce clogs.Most soap dispenser problems are caused by soap that is too thick or corrosive, or by a lack of maintenance.Many soaps come in concentrate form which must be diluted with water. Often, the soap is improperly dilutedor used straight out of the bottle, which causes clogging and valve failure. If proper soap is being used, valvesthat have never been cleaned are usually the source of dispensing problems. Bradley has entered into an agree-ment with Champion Brand Products to provide additional customer service for purchasers of our dispensersregarding soap issues. They are very helpful and can get to the bottom of almost any soap dispenser relatedproblem. They also sell an excellent "Bradley approved" soap. Please see Soap Instruction Sheet 215-1286for details about soap valve cleaning or how to contact Champion. With proper maintenance and soap, Bradleydispensers will provide long term, trouble free operation.

SOAP DISPENSER MAINTENANCE INSTRUCTIONS

Sentry WashfountainsBradley soap dispensers will provide dependable, consistent operation over the long term when the propersoap is used and when a minimal amount of periodic maintenance is performed on the valves. Valves must bemaintained (cleaned) to function properly. To ensure proper operation of your soap dispenser, follow these instructions:• Once per month, remove the cap from the soap tank and insert the draw tube (below the cap) into hot water

and soak it for 30 minutes.• Push valve at least 20 times while it is soaking.• Flush soap reservoir with hot water while valve is soaking.In cases of extreme clogging, the valve should be disassembled and the parts should be soaked in hot water orcleaning solution to restore proper functioning. Soap dispensers that will not be used for extended periods oftime (schools during summer break, etc.) should be drained, cleaned and left empty until put back into service.Soap left on the outside of dispensers can cause discoloration and corrosion of the reservoir (even on stainlesssteel units). All soap should be wiped or scrubbed off daily, then the outside of the dispenser should be rinsedwith clear water and dried with a soft cloth.

Soap System ....Continued

Page 35: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 352/12/07

Pedestal Assembly — Access Panels, Bowl Hardware, Drain Parts

Drain

6

8

9

10

11

121

5

7

4

2

3

1 S29-021 1 P-Trap 1½"2 113-731 1 Close Nipple 1½"3 269-557 1 Tee-Y 1½"4 S29-083 1 Tailpiece 1½"5 112-028 1 Drain Spud6 173-002 1 Strainer7 160-042 2 Screw for strainer8 142-063 1 Washer for spud9 161-148 1 Nut for spud

Item Part No. Qty Description

Parts List — Drain

10 142-002AT 3 or 4 Flat Washer ¼"11 142-002BS 3 or 4 Lock Washer ¼"12 161-026 3 or 4 Hex Nut ¼"-20

Item Part No. Qty Description

Parts List — Bowl Hardware

SN2003 186-1207 1 STD/JUVSN2004 186-1207 1 STD/JUVSN2005 186-1202 2 STD/JUVSN2008 186-1202 2 STD/JUVSN2013 186-1397 1 STD/JUVSN2023 186-1207 1 WALLSN2024 186-1207 1 WALLSN2033 186-1397 1 WALL

Model No. Part No. Qty Height

Parts List — Access Panel

For attaching bowl to pedestal.

Access Panel Screws, #10-24 x 1/2" long P/N 160-120

Page 36: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

36 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Backsplash Retrofit Kits — S65-237 for 36" Semi, S65-238 for 54" Semi

Installation1. Loosen the bowl anchors.2. Slide the backsplash between the wall and bowl making sure the slots on the backsplash are

aligned with the bolts.3. Caulk the lower edge of the backsplash where it meets the bowl.4. Tighten the bowl anchors.

Parts List — Backsplash Retrofit Kit

3 S65-237 1 36" Semi-Circle3 S65-238 1 54" Semi-Circle

Item Part No. Qty Description

Sentry Bowl

Bowl Anchor

Place a thin beadof caulk here

Backsplash

Page 37: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Parts and Service Guide Sentry™ Washfountain

Bradley Corporation • 215-1472 Rev. F; EN 06-915 372/12/07

Shroud/Towel Dispenser — Installed on a Shroud

2 7

4

8

63

51

Shroud

Finished Ceiling

10

9

Corner & Semi CircleItem Part No. Description Qty Qty

1 S70-095 Mounting Bracket - for shroud mtg. 2 22 S78-002 Towel Dispenser - Single fold 2 32 S78-001 Towel Dispenser - Multi fold 2 3* S45-183 Prepack - For shroud mounting — —3 160-169 Screw - Bracket to shroud (included in S45-183) 6 64 160-138 Screw - Shroud to cover 3 35 S57-040 Slip Ring for shroud 1 16 — Shroud - Call for part number 1 17 S10-009 Soap Filler Cap 2 28 107-445 Sprayhead Cover for Shroud 1 19 140-212E Restraining Bracket for Towel Dispenser, 36" 2 Semi only —9 140-212F Restraining Bracket for Towel Dispenser, 54" 2 Semi only —

10 140-927 Restraining Bracket for Towel Dispenser 2 Corner only —

Parts List — Shroud Installations

* Not Illustrated.

Page 38: Sentry Washfountain Parts & Service Guideigate.northernplumbing.com/partsbreakdowns/bradley/sn2003.pdf · Sentry™ Washfountain Parts and Service Guide 4 Bradley Corporation 2/12/07

Sentry™ Washfountain Parts and Service Guide

38 Bradley Corporation • 215-1472 Rev. F; EN 06-9152/12/07

Towel Dispenser — Installed on a Pipe

Corner & Semi CircleItem Part No. Description Qty Qty

1 S70-123 Mounting Bracket - for 1½" pipe mtg. 2 22 S78-002 Towel Dispenser - Single fold 2 32 S78-001 Towel Dispenser - Multi fold 2 3* S45-205 Prepack - for 1½" pipe mtg. — —3 159-020 Tie Bar-Tie Pipe (included in S45-205) 2 24 160-208 Screw - Tie bar to pipe (included in S45-205) 6 65 160-111 Screw - Bracket to tie bar (included in S45-205) 4 46 169-986A Pipe Cap (included in S45-205) 1 17 113-170 Spacer Sleeve - for 1½" pipe mtg. 1 18 140-212E Restraining Bracket for Towel Dispenser, 36" 2 Semi only —8 140-212F Restraining Bracket for Towel Dispenser, 54" 2 Semi only —9 140-927 Restraining Bracket for Towel Dispenser 2 Corner only —

Parts List — Pipe Installations

2

3

7

9

4

5 1

86

Pipe

1-1/2" NPT Pipe(Supplied by

Installer)

* Not Illustrated.


Recommended