Home > Documents > Serial Data Converter ILPH RS 232 - RS 485 / Ethernet ...

Serial Data Converter ILPH RS 232 - RS 485 / Ethernet ...

Date post: 05-Dec-2021
Category:
Upload: others
View: 9 times
Download: 0 times
Share this document with a friend
2
8 7 6 5 4 3 2 1 Speed Speed Odd parity Parity 2 Stop bit Disable Transparent mode Switch enable Speed Speed Even parity No parity 1 Stop bit AC31 mode enable Modbus slave Soft config enable ON SWB 4 3 2 1 Speed No end resistance GND not polarized VCC not polarized Not used End resistance GND line polarized VCC line polarized ON SWA 51 2.01" 43 1.69" 75 2.95" 94 3.70" 6 5 4 3 2 1 8 7 ON OFF SWB 4 3 2 1 ON OFF SWA 102 4.01" 94 3.70" 94 3.70" 22.5 .886" D E A GND RX TX Ethernet LINK TXD RXD e-ILPH SPEED PWR ACTIVITY M L K J H G M L K D E A GND RX TX Ethernet LINK TXD RXD e-ILPH SPEED PWR ACTIVITY M L K J H G M L K 4 3 2 1 ON 4 3 2 1 ON 5 6 7 8 PWR ISO GND ISO GND Rx LINK Tx D E M K L ETHERNET POWER RS 485 RS 232 +5V +5V +3.3V GND ISO ISO 1 6 +5V SWA3 SWA2 SWA1 +3.3V A GND GND TX RX GND GND RTS GND D E A GND RX TX Ethernet LINK TXD RXD e-ILPH SPEED PWR ACTIVITY M L K +24V 0V 24V TX TX GND RX RX B1+ B2- M J H G M L K D E A GND RX TX Ethernet LINK TXD RXD e-ILPH SPEED PWR ACTIVITY M L K J H G M L K 4 3 2 1 ON 4 3 2 1 ON 5 6 7 8 K L D E A RS 485 e-ILPH guide d'utilisation ABB Entrelec 1SNB002323R2100 Extraction 3. Technical specifications Power supply 24 V AC/DC Redundant 24 V DC Power supply 10 V AC to 24 V AC 10 V DC to 34 V DC voltage limit 10 V DC to 34 V DC Tolerance -10 %, +10 % Information 1 yellow "power on" Led Protection Alternative current Polarity inversion Consumption < 2 Watt (on whole range) Galvanic isolation RS 232-RS 485 750 V DC Ethernet 1500 V AC Connection Screw-type plug-in Screw connection connector 5.08 mm (D, E, A) RS 232 and RS 485 Link EIA RS 232 C/ EIA RS 485 CCITT V24/V28 Max. speed/ 115200 Bauds/ 115200 Bauds/ Distance 15m 1200m Galvanic isolation 750 V DC Information 2 green Led (RxD, TxD) Connection SubD9 or Screw-type screw connection plug-in connector Transmitter can 1 receiver up to 31 receivers communicate with : simultaneously Ethernet Link Interface Ethernet 10 Base-T or 100 Base-TX Connector RJ45 Speed 10/100 Mbit/s, auto sensing Distance 100 m to next switch or hub with CAT5 cable Galvanic isolation 1500 V AC Information led Activity / Speed, LINK (TCP connection) Physical characteristics Operating temperature 0 to +60 °C Storage temperature -20 to +70 °C P/N : 1SNA 684 252 R0200 Serial Data Converter ILPH RS 232 - RS 485 / Ethernet ISOLATED e-ILPH 4. Default parameters Modbus TCP slave mode Speed: 9600 Bauds 8 Bits,1 Stop Bit, No parity Control of flux: No IP Address: 10.33.152.76 Automatic programming: yes Asynchronous list: No SWB-1 to ON: soft configuration enable 5. Configuration Two modes are available to configure this product: - Switch mode: SWB-1 to OFF (Even if you use the switch configuration you have to configure the IP Address by software Cf. chap 5.2 Configuration by software). - Software mode: SWB-1 to ON (All parameters configured by soft) 5.1 Configuration by Switch Open the box on label side to modify switch position SWB-2 ON MODBUS/TCP slave mode OFF Tunnel mode (transparent mode) SWB-3 ON Enable to program the AC31 OFF Disable to Program AC31 SWB-4 ON 1 Stop bit OFF 2 Stop bits SWB-5 ON No parity OFF Parity SWB-6 ON Even parity OFF Odd parity SWB-7 and SWB-8 (Choose in the table beside the communication speed) SWB-7 SWB-8 Speed Off Off 9600 On Off 38400 Off On 57600 On On 115200 SWA-1 and SWA-2 ON Line polarized (GND for SWA-2, VCC for SWA-1) OFF Line not polarized SWA-1 and SWA-2, have to be on same position SWA-3 ON RS 485 End bus adaptor resistance OFF No RS 485 End bus adaptation SWA-4 Not used 5.2 Configuration by Software - Values are validated by pressing "Enter" key. - Corrections could be done by "Backspace" key before "Enter" is pressed. - For each parameter, actual value is indicated into parenthesis, to keep this value, press "Enter" key. - Choice Y or N (Yes/No values) could be done in capital or small letters. 1. General This interface realizes the conversion between a RS 232 or/and RS 485 serial signal and a TCP/IP connection signal (RJ45 support for 10/100 Base T link), including a galvanic isolation. This interface could be used in slave MODBUS/TCP protocol (server mode), direct connection (tunnel) in server or client mode, and is able to send mail via SMTP protocol using simple HAYES command on the serial line. 2. Schematic Diagram Set up menu with TCP connection: - With TELNET: Click on Start / Execute. Enter command TELNET 10.33.152.76 (or IP address already modified). The menu appears. Type "Enter", configuration menu is started. - With HYPERTERMINAL: Launch HyperTerminal windows, set communication "TCP/IP (Winsock)", set IP address and port "23". Set up with serial connection: Connect PC to RS 232 (if SubD9 connector is used, connect with a cross cable). Always set serial parameter to 9600 baud, 8 bits, no parity, 1 stop bit, no flux control. Switch off e-ILPH, press "x" key and maintain this key press while power on the e-ILPH. Then menu mode is displayed after few seconds. Menu description 0 – Network configuration: IP address, input address, gateway... 1 – Serial Line Parameters: Speed, characters, parity… 2 – Operation Mode: Slave MODBUS/TCP, Transparent server or client, mail mode... 3 – Factory defaults 4 – Exit without save 5 – Save and Exit 6 – English/French. 6. Connection For more information please contact your seller or find the complete documentation 1SNB 002 323 R2100 on the ABB.com 7. Visualization PWR Lights with power supply ON LINK Lights during active TCP connection TXD Lights during emission on serial port RXD Lights during reception on serial port SPEED Amber color: 10 base-T connection Green color: 100 base-TX connection ACTIVITY Momentary amber color, half duplex activity Momentary green color, full duplex activity 8. Special functions - Concentrator mode (Asynchronous): In Modbus/TCP, e-ILPH is used with an exchange table and concentrates the information. - AC31 programming: e-ILPH could be used to program point to point, the 40/50 series via TCP/IP connection in switching to programming mode. Configuration Open the box on label side to modify switch position RS 232 connection could be done wire less on M, L, K or SubD9 points SubD9 connector pin 2 = RX pin 3 = TX pin 5 = GND pin 7 = RTS With RS 232 cross TX and RX from the 2 devices Power supply
Transcript
Page 1: Serial Data Converter ILPH RS 232 - RS 485 / Ethernet ...

87

65

43

21

Speed

Speed

Odd parity

Parity

2 Stop bit

Disable

Transparent mode

Switch enable

Speed

Speed

Even parity

No parity

1 Stop bit

AC31 mode enable

Modbus slave

Soft config enable ON

SWB

43

21

Speed

No end resistance

GND not polarized

VCC not polarized

Not used

End resistance

GND line polarized

VCC line polarized ON

SWA

51 2.01" 43 1.69"

75 2.95"

94 3.70"

6

5

4

3

2

1

8

7

ON OFF

SWB

4

3

2

1

ON OFFSWA

102

4.01"

94 3.70"

94 3.70"

22.5

.886"

DE

A

GN

DR

XTX

Ethernet

LINK

TXD

RX

D

e-ILPHSPEED

PW

R

ACTIVITY

MLK

JH

G

ML

K

DE

A

GND

RX

TX

Ethernet

LINK

TXD

RXD

e-ILPH

SPEE

D

PWR

ACTIVITY

M LK

JH

G

ML

K

43

21

ON

43

21

ON56

78

PWR

ISO

GNDISO

GND

Rx

LINK

Tx

DE

M

K

L

ET

HE

RN

ET

PO

WE

R

RS

485

RS

232

+5V

+5V

+3.3V

GNDISO

ISO

1 6

+5V

SWA3

SWA2

SWA1

+3.3V

A

GND

GND

TX

RX

GND

GND

RTS

GND

D E A

GNDRX TX

Ethernet

LINK

TXD

RXD e-ILPH

SPEED

PWR

ACTIVITY

M L K

+24V0V

24V

TXTX

GND

RXRX

B1+

B2-

M

JH

G

ML

K

DE

A

GND

RX

TX

Ethernet

LINK

TXD

RXD

e-ILPH

SPEE

D

PWR

ACTIVITY

M LK

JH

G

ML

K

43

21

ON

43

21

ON56

78

KL

DE A

RS 485

e-ILPH

guide d'utilisation ABB Entrelec

1SNB002323R2100 Extraction

3. Technical specifications

Power supply

24 V AC/DC Redundant 24 V DCPower supply 10 V AC to 24 V AC 10 V DC to 34 V DC voltage limit 10 V DC to 34 V DCTolerance -10 %, +10 % Information 1 yellow "power on" LedProtection Alternative current Polarity inversion Consumption < 2 Watt (on whole range) Galvanic isolation RS 232-RS 485 750 V DC Ethernet 1500 V ACConnection Screw-type plug-in Screw connection connector 5.08 mm (D, E, A)

RS 232 and RS 485 Link

EIA RS 232 C/ EIA RS 485 CCITT V24/V28 Max. speed/ 115200 Bauds/ 115200 Bauds/ Distance 15m 1200mGalvanic isolation 750 V DCInformation 2 green Led (RxD, TxD)Connection SubD9 or Screw-type screw connection plug-in connectorTransmitter can 1 receiver up to 31 receivers communicate with : simultaneously

Ethernet Link

Interface Ethernet 10 Base-T or 100 Base-TXConnector RJ45Speed 10/100 Mbit/s, auto sensingDistance 100 m to next switch or hub with CAT5 cableGalvanic isolation 1500 V ACInformation led Activity / Speed, LINK (TCP connection)

Physical characteristics

Operating temperature 0 to +60 °CStorage temperature -20 to +70 °C

P/N : 1SNA 684 252 R0200

Serial Data Converter ILPH RS 232 - RS 485 / Ethernet ISOLATED e-ILPH

4. Default parameters

Modbus TCP slave modeSpeed: 9600 Bauds 8 Bits,1 Stop Bit, No parity Control of flux: No IP Address: 10.33.152.76Automatic programming: yesAsynchronous list: No SWB-1 to ON: soft configuration enable

5. ConfigurationTwo modes are available to configure this product:- Switch mode: SWB-1 to OFF (Even if you use the switch configuration you have to configure the

IP Address by software Cf. chap 5.2 Configuration by software).- Software mode: SWB-1 to ON (All parameters configured by soft)

5.1 Configuration by SwitchOpen the box on label side to modify switch position

SWB-2 ON MODBUS/TCP slave mode OFF Tunnel mode (transparent mode)

SWB-3 ON Enable to program the AC31 OFF Disable to Program AC31

SWB-4 ON 1 Stop bit OFF 2 Stop bits

SWB-5 ON No parity OFF Parity

SWB-6 ON Even parity OFF Odd parity

SWB-7 and SWB-8 (Choose in the table beside the communication speed)

SWB-7 SWB-8 SpeedOff Off 9600On Off 38400Off On 57600On On 115200

SWA-1 and SWA-2 ON Line polarized (GND for SWA-2, VCC for SWA-1) OFF Line not polarizedSWA-1 and SWA-2, have to be on same position

SWA-3 ON RS 485 End bus adaptor resistance OFF No RS 485 End bus adaptation

SWA-4 Not used

5.2 Configuration by Software- Values are validated by pressing "Enter" key.- Corrections could be done by "Backspace" key before "Enter" is

pressed.- For each parameter, actual value is indicated into parenthesis, to

keep this value, press "Enter" key.- Choice Y or N (Yes/No values) could be done in capital or small

letters.

1. GeneralThis interface realizes the conversion between a RS 232 or/and RS 485 serial signal and a TCP/IP connection signal (RJ45 support for 10/100 Base T link), including a galvanic isolation. This interface could be used in slave MODBUS/TCP protocol (server mode), direct connection (tunnel) in server or client mode, and is able to send mail via SMTP protocol using simple HAYES command on the serial line.

2. Schematic Diagram

Set up menu with TCP connection: - With TELNET: Click on Start / Execute. Enter command TELNET

10.33.152.76 (or IP address already modified). The menu appears. Type "Enter", configuration menu is started.

- With HYPERTERMINAL: Launch HyperTerminal windows, set communication "TCP/IP (Winsock)", set IP address and port "23".

Set up with serial connection:Connect PC to RS 232 (if SubD9 connector is used, connect with a cross cable). Always set serial parameter to 9600 baud, 8 bits, no parity, 1 stop bit, no flux control. Switch off e-ILPH, press "x" key and maintain this key press while power on the e-ILPH. Then menu mode is displayed after few seconds.

Menu description0 – Network configuration: IP address, input address, gateway...1 – Serial Line Parameters: Speed, characters, parity…2 – Operation Mode: Slave MODBUS/TCP, Transparent server or

client, mail mode...3 – Factory defaults4 – Exit without save5 – Save and Exit6 – English/French.

6. Connection

For more information please contact your seller or find the complete documentation 1SNB 002 323 R2100 on the ABB.com

7. VisualizationPWR Lights with power supply ONLINK Lights during active TCP connectionTXD Lights during emission on serial portRXD Lights during reception on serial portSPEED Amber color: 10 base-T connection

Green color: 100 base-TX connectionACTIVITY Momentary amber color,

half duplex activity Momentary green color, full duplex activity

8. Special functions- Concentrator mode (Asynchronous): In Modbus/TCP, e-ILPH is

used with an exchange table and concentrates the information. - AC31 programming: e-ILPH could be used to program point

to point, the 40/50 series via TCP/IP connection in switching to programming mode.

ConfigurationOpen the box on label side to modify switch position

RS 232 connection could be done wire less on M, L, K or SubD9 points

SubD9 connector

pin 2 = RXpin 3 = TXpin 5 = GNDpin 7 = RTS

With RS 232 cross TX and RX from the 2 devices

Power supply

1SNB002323R2100.indd 8 13/01/2006 08:10:58

Page 2: Serial Data Converter ILPH RS 232 - RS 485 / Ethernet ...

87

65

43

21

Speed

Speed

Odd parity

Parity

2 Stop bit

Disable

Transparent mode

Switch enable

Speed

Speed

Even parity

No parity

1 Stop bit

AC31 mode enable

Modbus slave

Soft config enable ON

SWB

43

21

Speed

No end resistance

GND not polarized

VCC not polarized

Not used

End resistance

GND line polarized

VCC line polarized ON

SWA

51 2.01" 43 1.69"

75 2.95"

94 3.70"

6

5

4

3

2

1

8

7

ON OFF

SWB

4

3

2

1

ON OFFSWA

102

4.01"

94 3.70"

94 3.70"

22.5

.886"

DE

A

GN

DR

XTX

Ethernet

LINK

TXD

RX

D

e-ILPHSPEED

PW

R

ACTIVITY

MLK

JH

G

ML

K

DE

A

GND

RX

TX

Ethernet

LINK

TXD

RXD

e-ILPH

SPEE

D

PWR

ACTIVITY

M LK

JH

G

ML

K

43

21

ON

43

21

ON56

78

PWR

ISO

GNDISO

GND

Rx

LINK

Tx

DE

M

K

L

ET

HE

RN

ET

PO

WE

R

RS

485

RS

232

+5V

+5V

+3.3V

GNDISO

ISO

1 6

+5V

SWA3

SWA2

SWA1

+3.3V

A

GND

GND

TX

RX

GND

GND

RTS

GND

D E A

GNDRX TX

Ethernet

LINK

TXD

RXD e-ILPH

SPEED

PWR

ACTIVITY

M L K

+24V0V

24V

TXTX

GND

RXRX

B1+

B2-

M

JH

G

ML

K

DE

A

GND

RX

TX

Ethernet

LINK

TXD

RXD

e-ILPH

SPEE

D

PWR

ACTIVITY

M LK

JH

G

ML

K

43

21

ON

43

21

ON56

78

KL

DE A

RS 485

e-ILPH

guide d'utilisation ABB Entrelec

1SNB002323R2100 Extraction

3. Spécifications techniques

Alimentation

24 V AC/DC 24 V DC RedondantLimites 10 V AC à 24 V AC 10 V DC à 34 V DC d’alimentation 10 V DC à 34 V DCTolérance -10 %, +10 % Information 1 LED jaune "Alimenté"Protection Courant Alternatif Inversion de Polarité Consommation < 2 Watt (sur toute la plage) Isolation galvanique RS 232-RS 485 750 V DC Ethernet 1500 V ACConnexion Connexion vissée Connexion vissée débrochable (D, E, A) 5.08 mm

Liaison RS 232 et RS 485

EIA RS 232 C/ EIA RS 485 CCITT V24/V28 Vitesse 115200 Bauds/ 115200 Bauds/ Max./distance 15m 1200mIsolation galvanique 750 V DCInformation 2 LED vertes (RxD, TxD)Connexion SubD9 ou Connexion vissée connexion vissée débrochableLe transmetteur peut 1 récepteur jusqu’à 31 récepteurs communiquer avec : simultanément

Liaison Ethernet

Interface Ethernet 10 Base-T ou 100 Base-TXConnecteur RJ45Vitesse 10/100 Mbit/s, sélection automatiqueDistance 100 m jusqu’au switch ou hub suivant, avec câble CAT5Isolation galvanique 1500 V ACInformation LED Activité / Vitesse, LINK (TCP connexion)

Caractéristiques mécaniques

Température opérationnelle 0 à +60 °CTempérature de stockage -20 à +70 °C

4. Paramètres d’usineModbus TCP slave modeVitesse : 9600 Bauds 8 Bits,1 Stop Bit, pas de parité Contrôle de flux : Non Adresse IP : 10.33.152.76Programmation automatique : ouiListe asynchrone : Non SWB-1 sur ON : configuration par logiciel

5. ConfigurationDeux modes sont disponibles pour configurer le produit :- Mode par Switch : SWB-1 à OFF (Même si vous utiliser ce mode, vous devez configurer l’adresse

IP par logiciel Cf. chap. 5.2 Configuration logiciel).- Mode programmation : SWB-1 à ON (Tous les paramètres sont configurables)

5.1 Configuration par switchOuvrir le boîtier côté étiquette pour modifier la position des switch

SWB-2 ON Mode MODBUS/TCP esclave OFF Mode Tunnel (transparent)

SWB-3 ON Autorise la programmation AC31 OFF Interdit la programmation AC31

SWB-4 ON 1 bit de Stop OFF 2 bits de Stop

SWB-5 ON Pas de parité OFF Parité

SWB-6 ON Parité paire OFF Parité impaire

SWB-7 et SWB-8 (Choisir dans la table ci-dessous la vitesse de communication)

SWB-7 SWB-8 VitesseOff Off 9600On Off 38400Off On 57600On On 115200

SWA-1 et SWA-2 ON Ligne polarisée (GND pour SWA-2, VCC pour SWA-1) OFF Ligne non polariséeSWA-1 et SWA-2, doivent être dans la même position

SWA-3 ON Résistance de fin de ligne RS 485 OFF Pas de résistance de fin de ligne RS 485

SWA-4 Non utilisé

5.2 Configuration par Logiciel- Les valeurs sont validées par la touche "Entrer"- Avant validation, une correction peut être faite par la touche

"Effacer"- Pour chaque paramètre, la valeur actuelle est indiquée entre

parenthèses, pour garder cette valeur presser "Entrer".- Sélection O ou N (Oui ou Non) peut être écrite en minuscules ou

majuscules.

1. PrésentationCette interface réalise la conversion entre une liaison série RS 232 ou/et RS 485 et un signal sur TCP/IP (support RJ45 pour 10/100 Base T), incluant une isolation galvanique. L’interface peut être utilisée en protocole MODBUS/TCP esclave, connexion directe (tunnel) en mode serveur ou client, ou peut envoyer des mails via le protocole SMTP en utilisant une simple commande HAYES sur la liaison série.

2. Schéma de principe

Réf. commerciale : 1SNA 684 252 R0200

Configuration par la connexion TCP : - Commande DOS, TELNET : Cliquer sur Démarrer / Exécuter.

Entrer la commande TELNET 10.33.152.76 (ou l’adresse IP déjà modifiée) pour faire apparaît le menu. Appuyer "Entrer" pour démarrer la configuration.

- Programme Window, HYPERTERMINAL : Ouvrir le logiciel, sélection-ner le port "TCP/IP (Winsock)", entrer l’adresse IP et port "23".

Configuration par la liaison série :Connecter le PC à la RS 232 (si vous utiliser le connecteur SubD9, utiliser un câble croisé). Toujours mettre les paramètres série à : 9600 bauds, 8 bits, pas de parité, 1 bit de stop, pas de contrôle de flux. Mettre hors tension l’e-ILPH, maintenir la touche "x" durant la mise sous tension de celui-ci. Le menu apparaît après quelques secondes.

Description menu0 – Configuration réseau : adresse IP, adresse d'entrée, passerelle...1 – Paramètres de la ligne série : vitesse, caractères, parité…2 – Mode de fonctionnement : esclave MODBUS/TCP, serveur ou

client transparent, mode mail...3 – Configuration d’usine 5 – Sortie avec sauvegarde4 – Sortie sans sauvegarde 6 – Anglais/Francais

6. Connexion

Pour plus d’information, contacter votre revendeur ou voir la documen-tation complète sur le site ABB.com Réf. 1SNB 002 323 R2100.

7. VisualisationPWR Allumé présence tensionLINK Allumé durant l’activité sur la connexion TCP TXD Allumé durant l’émission sur le port série RXD Allumé durant la réception sur le port sérieSPEED Couleur ambrée : connexion 10 base-T

Couleur verte : connexion 100 base-TXACTIVITY Couleur ambrée momentanée,

activité half duplex Couleur verte momentanée, activité full duplex

8. Fonctions Spéciales- Mode concentrateur (Asynchrone) : en Modbus/TCP, l’e-ILPH

est utilisé avec une table d’échange et concentre les informations.- Programmation AC31 : il est possible de programmer les séries 40/50

via la connexion TCP/IP à travers l’e-ILPH en liaison point à point.

Interface de liaison série ILPH RS 232 - RS 485 / Ethernet ISOLE e-ILPH

ConfigurationOuvrir le boîtier côté étiquette

pour modifier les switch

RS 232 peut être connecté en fils libres sur M, L, K ou sur SubD9 points

connecteur SubD9 picot 2 = RXpicot 3 = TXpicot 5 = GNDpicot 7 = RTS

En RS 232 croiser TX et RX des 2 appareils