DX Wet/Wet Differential Pressure Switch The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc
Transcript
Page 1: Series DX

DX Wet/Wet Differential Pressure Switch

The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc.

©Copyright 2011 Dwyer Instruments, Inc

Page 2: Series DX

DX Wet/Wet Differential Pressure Switch

Differential Pressure Switch for waterGives us a low cost product to round out product offering as an alternative to the H3 and DP

Page 3: Series DX

Features

Pipe or flush mount with provided mounting earsWeatherproof constructionHigh static pressure ratingTight deadbandExternal set point adjustment

Page 4: Series DX

Specifications

Temperature Limits: -1 to 60 C Enclosure Rating: IP66Maximum Pressure: 13.8 barRepeatability: 2% of full rangeProcess Connection: 1/4” – 18 NPT FemaleWetted Materials: Brass and Viton (Option for Buna N)

Page 5: Series DX

Specifications

Switch Type: SPDT snap switch Electrical Rating: 5A @ 125 VAC, 3A @ 250 VAC, 4A @ 30 VDCElectrical Connection: Removable terminal blockConduit Connection: Hole for conduit hub, optional cable gland

Page 6: Series DX

Specifications

Agency Approvals: UL508, ULc, CESet Point Adjustment: External, hand adjustable hex head screwMounting Orientation: Vertical, 10

Page 7: Series DX

Ranges

List Price: $69.00 Adjustable Range

bar

Fixed Deadband bar

0.17 to 0.69 0.10 to 0.17

0.69 to 1.72 0.17 to 0.24

1.38 to 3.45 0.24 to 0.41

3.46 to 5.17 0.41 to 0.55

Page 8: Series DX

Options

Watertight cable glandPresetBuna N diaphragmFuture Ability:

316 SS connectionsConnections of ¼” SAE or BSPT

Page 9: Series DX

Applications

Water FiltrationUsed to initiate backwash of the filter. These can be bag filters, sand filters, and disc filters. Starts on increase of differential pressure. Filters are varied in application from irrigation systems to cooling towers.

Page 10: Series DX

Applications

Coolant FiltersUsed to initiate backwash of filter. Starts on increase of differential pressure. These are filters used to clean the coolant used on machining systems. Cleans out the metal bits from the coolant.

Page 11: Series DX

Applications - BAS

ChillersProves flow of liquid from pump through the chiller. Often called evaporator water pressure drop.

Page 12: Series DX

Applications - Chiller

All Trane units are pre-packaged with a vane flow switch. The majority of integrators and installers feel these are problematic and throw them away and use a DP switch or current switch.Trane variable flow pump units tend to use DP switches as a current switch doesn’t work as well on variable speed driven pumps.

Page 13: Series DX

Applications - BAS

AC Units or Heat PumpsUsed in buildings on the condenser water loop that goes between the cooling tower on the roof to the AC unit in a particular zone in a building. Usually each floor has one AC unit. Used in all high-rises.

Page 14: Series DX

Applications - BAS

AC Units or Heat PumpsOften called a “Condenser Water Lock-Out Switch”. AC unit will freeze up if no flow through it.

Page 15: Series DX

Applications - BAS

Key for BAS applications is the low set point. They are trip on a decrease of DP, so the unit can be set to .035 bar.Also key is tight deadband for early reset on increase of pressure.

Page 16: Series DX

Applications

General IndustryPump flow proving with DP across the pump.Flow proving with a flow element such as a venturi or an orifice plate.

Page 17: Series DX

Questions

To order a free catalog or for more information contact;Dwyer Instruments, Inc., P.O. Box 373,

Michigan City, IN., 46361Telephone: (800) 872-9141 or (219) 879-8000

Fax: (219) 872-9057Internet address: www.dwyer-inst.com