1150 SERIES ULTRA 3 LOW NO X TM LUMIFLAME REGENERATIVE BURNER DIMENSIONS - ALUMINUM APPLICATIONS “D” Catalog No. 1150- inches m 025 48.13 1.22 050 53.88 1.37 075 60.00 1.52 100 64.88 1.65 150 72.13 1.83 200 78.88 2.00 250 85.00 2.16 Dimension from centerline of burner to bottom of case. Not including support structure as shown on drawing. MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 1/10 © Bloom Engineering Co 2009 1
Transcript
Page 1: SERIES ULTRA3 LOW NOX LUMIFLAME REGENERATIVE BURNER DIM … ·  · 2012-06-261150 series ultra3 low no x tm lumiflame regenerative burner dimensions - aluminum applications ... -100-100

1150 SERIES ULTRA3 LOW NOX

TM LUMIFLAME REGENERATIVE BURNER

DIMENSIONS - ALUMINUM APPLICATIONS

“D” Catalog No.

1150- inches m 025 48.13 1.22 050 53.88 1.37 075 60.00 1.52 100 64.88 1.65 150 72.13 1.83 200 78.88 2.00 250 85.00 2.16

Dimension from centerline of burner to bottom of case. Not including support structure as shown on drawing.

MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations

1/10

© Bloom Engineering Co 2009 1

Page 2: SERIES ULTRA3 LOW NOX LUMIFLAME REGENERATIVE BURNER DIM … ·  · 2012-06-261150 series ultra3 low no x tm lumiflame regenerative burner dimensions - aluminum applications ... -100-100

1150 SERIES ULTRA3 LOW NOX

TM LUMIFLAME REGENERATIVE BURNER

ALUMINUM APPLICATIONS

Standard 10° Down

Note: Secondary air and exhaust connections are 125# flanges standard. RPM flanges optional. NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.

1/10

© Bloom Engineering Co 2009 2

Page 3: SERIES ULTRA3 LOW NOX LUMIFLAME REGENERATIVE BURNER DIM … ·  · 2012-06-261150 series ultra3 low no x tm lumiflame regenerative burner dimensions - aluminum applications ... -100-100

1150 SERIES ULTRA3 LOW NOX

TM LUMIFLAME REGENERATIVE BURNER

ALUMINUM APPLICATIONS

Burner Dimensions (inches) Catalog

No. 1150-

Burner Head/Case

Size A B C D E F G H I K L M N P -050-050 -- -- 34 16 33.75 30 43.13 -- 11 .5 6 -- -- -- -075-075 -- -- 34 20 48 30 47.25 -- 13 .5 6 -- -- -- -100-100 -- -- 38 22.5 53.75 34 54.88 -- 14.25 .5 6 -- -- -- -100-150 94.63 99.63 44 22.5 64.25 40 55.63 22.63 14.25 .5 6 39.50 34.63 15.19-150-150 -- -- 44 27.5 64.25 40 55.63 -- -- .5 6 -- -- -- -150-200 104 104.38 48.5 27.5 76.25 44.5 55.88 24 16.75 .5 6 39.50 41.44 18.13-200-200 -- -- 48.5 32 76.25 44.5 55.88 -- 19 .5 6 -- -- -- -200-250 105.38 118.25 55.5 32 80.88 51.5 64.5 26.94 19 .5 6 35.75 41.06 20.5-200-300 124 121.5 52 32 101 48 67.75 26.94 19 .5 6 35.75 41.06 29 -350-350 -- -- 54.75 42 110 50.75 66 -- 24 .5 6 -- -- --

Burner Dimensions (inches) Catalog

No. 1150-

Burner Head/Case

Size R S T U V W Z AA AB AC AD AE AF AG AH

-050-050 -- 8 -- -- 9.13 13.88 -- -- -- -- -- 13.5 11.75 .88 8 -075-075 -- 8 -- -- 15.25 13.88 -- -- -- -- -- 13.5 11.75 .88 8 -100-100 -- 10 6 3 17 16 -- -- -- -- -- 16 14.25 1 12 -100-150 .5 12 6 3 24.13 16 13.19 33.75 32 .88 28 19 17 1 12 -150-150 -- 12 -- -- 24.13 16 -- -- -- -- -- 19 17 1 12 -150-200 .5 14 6 4 24.13 15.88 17.5 39.50 37.38 1.25 28 21 18.75 1.13 12 -200-200 .5 14 6 4 24.13 15.88 -- -- -- -- -- 21 18.75 1.13 12 -200-250 .5 16 6 4 26.31 17.88 17.63 44 41.88 1.25 28 23.5 21.25 1.13 16 -200-300 .5 18 8 4 36.25 19.5 17.63 44 41.88 1.25 28 25 22.75 1.25 16 -350-350 -- 20 -- -- 38.88 19.38 -- -- -- -- -- 27.5 25 1.25 20

Note: -- = not yet existing/designed MANUFACTURED UNDER U.S. PATENT NO. 5,180,300 NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.

1/10

© Bloom Engineering Co 2009 3

Page 4: SERIES ULTRA3 LOW NOX LUMIFLAME REGENERATIVE BURNER DIM … ·  · 2012-06-261150 series ultra3 low no x tm lumiflame regenerative burner dimensions - aluminum applications ... -100-100

1150 SERIES ULTRA3 LOW NOX

TM LUMIFLAME REGENERATIVE BURNER

MEDIA CASE DIMENSIONS - ALUMINUM APPLICATIONS

General Dimensions (inches/mm) Media Case Size J K L M N P 025* 6 152 31 787 21 533 39.63 1006 8 203 13 330035* 8 203 33.50 851 23 584 43.13 1095 9 229 13.88 352050* 8 203 33.75 857 30 762 43.13 1095 9.13 232 13.88 352075 8 203 48 1219 30 762 47.25 1200 15.25 387 13.88 352100 10 254 53.75 1365 34 864 54.88 1394 17 432 16 406150 12 305 64.25 1632 40 1016 55.63 1413 24.13 613 16 406200 14 356 76.25 1937 44.50 1130 55.88 1419 24.13 613 15.88 403250 16 406 80.88 2054 51.50 1308 64.50 1638 26.31 668 17.88 454300 18 457 101 2565 48 1219 67.75 1721 36.25 921 19.50 495350 20 508 110 2794 50.81 1289 66.00 1676 38.88 987 19.38 492

*Hinged door not available on this size. NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.

1/10

© Bloom Engineering Co 2009 4

Page 5: SERIES ULTRA3 LOW NOX LUMIFLAME REGENERATIVE BURNER DIM … ·  · 2012-06-261150 series ultra3 low no x tm lumiflame regenerative burner dimensions - aluminum applications ... -100-100

1150 SERIES ULTRA3 LOW NOX

TM LUMIFLAME REGENERATIVE BURNER

COMPRESSED AIR CONSUMPTION

025 to 150 = 1 cfm/actuator design 200 to 250 = 2.5 cfm/actuator design Air quality “reasonably clean and dry and to a quality class 4.5.5 (according to ISO standard 8573.1)”. This implies 25 micron maximum particle size, 7°C dew point maximum (or lower than ambient temperature below 7°C) and 25 mg/cubic meter maximum oil content.

APPROXIMATE BURNER WEIGHTS

Total Weight Burner Head Media Case w/ Media Media Catalog

No. 1150- lbs kg lbs kg lbs kg lbs kg

025 2110 957 620 281 1490 676 440 200 050 3600 1633 1295 587 2305 1046 880 399 075 4830 2191 1400 635 3430 1556 1265 574 100 6410 2908 2225 1009 4185 1898 1760 798 150 9815 4452 3150 1429 6665 3023 2475 1123 200 11805 5355 3695 1676 8110 3679 3740 1696 250 13980 6341 4575 2075 9405 4266 4785 2170

FLAME INFORMATION The flame envelope must be free from obstructions in order to achieve the low NOX benefits of the burner. Additionally, any modifications to the burner intended to shorten the envelope will increase the predicted NOX.

Flame Dimensions for Nominal Capacities Natural Gas Fuel with 10% Excess Air Combustion Air

Nominal Capacities Standard Port ID Expected Flame Length

Expected Flame Diameter

Catalog No.

1150- scfh Nm3/hr inches mm feet m feet m 025 27,500 743 11.5 292 6.0 1.83 2.0 0.61 035 38,500 1,041 13.5 343 7.0 2.13 2.5 0.76 050 55,000 1,486 16.0 406 8.5 2.59 2.5 0.76 075 82,500 2,230 20.0 508 10.0 3.05 3.0 0.91 100 110,000 2,973 22.5 572 11.5 3.51 4.0 1.22 150 165,000 4,459 27.5 699 14.0 4.27 4.5 1.37 200 220,000 5,946 32.0 813 16.0 4.88 5.0 1.52 250 275,000 7,432 35.5 902 17.5 5.33 6.0 1.83 300 330,000 8,919 39.0 991 19.0 5.79 6.5 1.98 350 385,000 10,405 42.0 1067 20.5 6.25 7.0 2.13

Note: 1150 Series flame lengths on oil firing are approximately 25% longer

and flame diameters on oil are slightly less than those listed above.

CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations

1/10

© Bloom Engineering Co 2009 5

Page 6: SERIES ULTRA3 LOW NOX LUMIFLAME REGENERATIVE BURNER DIM … ·  · 2012-06-261150 series ultra3 low no x tm lumiflame regenerative burner dimensions - aluminum applications ... -100-100

1150 SERIES ULTRA3 LOW NOX

TM LUMIFLAME REGENERATIVE BURNER

ROOF MOUNTED MEDIA CASE

General Dimensions (inches/mm) Approximate

Weight w/o media

Catalog No.

1100-1150- A B C D E F G H J K lbs kg

59.75 47.0 38.5 33.75 31.0 9.0 28.0 26.0 12.0 11.0 025 1518 1194 978 857 787 229 711 660 305 279

3180 1442

64.25 55.0 42.13 36.5 34.0 12.63 31.63 27.75 12.0 12.0 050 1632 1397 1070 927 864 321 803 705 305 305

4160 1887

80.0 54.5 45.0 50.75 36.0 15.5 34.5 29.25 12.0 12.0 075 2032 1384 1143 1289 914 394 876 743 305 305

5180 2350

86.75 62.5 47.5 56.25 38.0 18.0 37.0 30.5 12.0 14.0 100 2203 1588 1207 1429 965 457 940 775 305 357

6350 2880

102.0 66.0 54.5 66.5 41.0 22.0 41.0 35.5 12.0 14.0 150 2591 1676 1384 1689 1041 559 1041 902 305 357

8090 3670

NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.

1/10

© Bloom Engineering Co 2009 6

Page 7: SERIES ULTRA3 LOW NOX LUMIFLAME REGENERATIVE BURNER DIM … ·  · 2012-06-261150 series ultra3 low no x tm lumiflame regenerative burner dimensions - aluminum applications ... -100-100

1150 SERIES ULTRA3 LOW NOX

TM LUMIFLAME REGENERATIVE BURNER

TYPICAL PORT/INSTALLATION CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.