Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com WARNINGS: •Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced. •Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main- tenance. AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta- tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo- cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance. ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes de mantenimiento. Page 1 DISTORT JOINT Feb 2019
Transcript
Page 1: Sero Qub Installation GP RetrofitJan19...Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770

Installation InstructionsSero / Qub Pendant

RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP”

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

WARNINGS:•Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced.

•Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main-tenance.

AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta-tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo-cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance.

ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes

de mantenimiento.

Page 1DISTORT JOINT

Feb 2019

Page 2: Sero Qub Installation GP RetrofitJan19...Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

Lighting SyStem ComponentS

***Every luminaire will have a companion driver enclosure, not all luminaires and driver enclosures are the same, please be sure to pair the proper driver enclosure to the proper luminaire by reading the packaging labels***

Page 2

Installation InstructionsSero / Qub Pendant

RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP”

Package Contents•Driver enclosure with bar hanger flange, remove for retrofit applications•Power Canopy Hardware Packet •(1) 5” diameter canopy •(1) Stainless Steel aircraft cable coupler •(1) 48” Plenum Rated Cord Sleeve •(1) 48” or 120” Aircraft Cable •(1) 8.25” Threaded Stem 1/4-20 (For Retrofit Only) •(1) 8.75” Threaded Stem 1/4-20 (New Con struction 5/8” Sheet Rock) •(1) 9.5” Threaded Stem 1/4-20 (for 1 1/4” sheet rock)

1. LUMINAIRE

1. CANOPY/ DRIVER ENCLOSURE

3. NON-POWER MOUNT HANGING HARDWARE

NON POWER

HARDWARE

Package Contents•Notes: Non-Power canopy hardware is only neces-sary for individual and row starter luminaires•Non-Power Canopy Hardware Packet •(1) 3” diameter canopy •(1) Stainless Steel aircraft cable coupler •(1) 48” or 120” aircraft cable

Package Contents•Luminaire•Includes factory installed 4 con-ductor low voltage power cord (48” Aircraft Cable = 78” Power Cord120” Aircraft Cable = 150” Power Cord)•Includes factory installed air-craft cable adjuster(s)

Feb 2019

Page 3: Sero Qub Installation GP RetrofitJan19...Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

Luminaire dimenSionSUnit Lengths

26 1/4” (667mm)

Individual

Continuous Row

Driver

Enclosure

50 1/4” (1276mm)

74 1/4” (1886mm)

98 1/4” (2496mm)

26 1/4” (667mm)

50 1/4” (1276mm)

74 1/4” (1886mm)

98 1/4” (2496mm)

Unit Lengths

26 1/4” (667mm)

Individual

Continuous Row

Driver

Enclosure

50 1/4” (1276mm)

74 1/4” (1886mm)

98 1/4” (2496mm)

26 1/4” (667mm)

50 1/4” (1276mm)

74 1/4” (1886mm)

98 1/4” (2496mm)

driver enCLoSure dimenSionS

Page 3

2 1/4”

4 1/4”

4 1/4”

2 1/4”

SERO

QuB

Installation InstructionsSero / Qub Pendant

RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP”

3.51”5.39”

6.74”

2.5”

7.44”

6.74”

4.54”

6.35”8.0

9”

4.35”

6.35”

Feb 2019

Page 4: Sero Qub Installation GP RetrofitJan19...Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770

5” Dia.

5” Dia.

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

inStaLLing an individuaL or row Starter Luminaire

Cut 5” Diameter hole into sheet rock and pull wires though hole

Remove and discard hanger bar flange after removing 3 screws

Remove top access cover and make low dimming wire con-nections if necessary

2

3

Page 4

Installation InstructionsSero / Qub Pendant

RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP”

Make line voltage wire connections

4

24” (609mm)48” (1219mm)72” (1828mm)96” (2438mm)

step 1

Purple (Dim)

Grey (Dim)White (Neutral)

Green (Ground)

Black (Hot)

White (Neutral)

Green (Ground)

Black (Hot)

Dimming Circuit

Line Voltage

Low voltage dimming

Feb 2019

Page 5: Sero Qub Installation GP RetrofitJan19...Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

inStaLLing an individuaL or row Starter Luminaire

Rotate two philips screws clock wise to secure brackets to sheet rock

7

Install the smallest threaded rod into center of driver enclo-sure

8

Thread cord, coupler and aircraft cable into canopy as shown

9

Page 5

Installation InstructionsSero / Qub Pendant

RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP”

Connect coupler and aircraft cable to threaded stem

10

re-attach splice cover

5

Insert driver enclosure into ceiling

6

Rec

ycle

Rec

ycle

Feb 2019

Page 6: Sero Qub Installation GP RetrofitJan19...Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

inStaLLing an individuaL or rowStarter Luminaire

Screw threaded coupler and non-power canopy onto mount-ing stem to physically hang luminaire

13

On non-power side thread aircraft cable though adjuster on luminaire (level and trim cable as last step)

Page 6

Installation InstructionsSero / Qub Pendant

RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP”

14

On power side thread aircraft cable though adjuster on lumi-naire (level and trim cable as last step)

12

Remove driver cartridge by pushing release pin, and make low voltage wire connection, then push driver assembly back into enclosure and attach 5” canopy as shown

11

Red

Red w/white stripe

Blue

Blue w/white stripeRelease

Pin

Feb 2019

Page 7: Sero Qub Installation GP RetrofitJan19...Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP” NULITE Lighting Inc. 10770

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com

inStaLLing arow-mid or row-end(aFter Starter haS Been inStaLLed, Step 2 or Step 3)

24” (609mm)48” (1219mm)72” (1828mm)96” (2438mm)

24” (609mm)48” (1219mm)72” (1828mm)96” (2438mm)

24” (609mm)48” (1219mm)72” (1828mm)96” (2438mm)

step 1 step 2 step 3

Repeat Steps 1-12 on page 4-6 to install next Grid driver enclosure in the row

***2 cable mounts in first fixture, only one ca-ble mount in each subsequent fixture***

1-12

Page 7

Installation InstructionsSero / Qub Pendant

RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option “GP”

13

Row Starter

Row Mid or Row End

Captive Spring Latch joins fixtures

After the “Row Mid” or “Row End” has been suspended at the far end, connect the luminaire to the “Row Start-er” by sliding the luminaires together and then using the spring latch to securely make the final connection.