1
SERS, Raman, IR and DFT investigation of 1-(2-pyridylazo)-2-naphthol and its metal complexes L. Szabó 1 *, K. Herman 1 , N. Leopold 1 , A. Fălămaş 1 , N. Mircescu 1 , C. Buzumurgă 2 , V. Chiş 1 1 Faculty of Physics, Babeş-Bolyai University, Kogalniceanu 1, 400084 Cluj-Napoca, Romania 2 “Nicolae Stăncioiu" Heart Institute, Moţilor 19-21, 400001 Cluj-Napoca, Romania *[email protected] Abstract Metal ions determination represents an area of interest in several fields, like environmental protection, food safety or clinical diagnostics. Analytical methodologies for direct determination of metal ions were established over the last decades including atomic absorption or emission spectroscopy and mass spectrometry. Although these methods are sensitive and accurate, they require tedious sample pre-treatment and expensive equipment. Thus, a significant increase in the development of optical chemical sensors for heavy metals has been noted in the last years, aiming to their routinely production, low cost, high selectivity and sensitivity. In this work, IR, Raman and SERS spectroscopy is used in conjunction with quantum chemical calculations in order to characterize the molecular structure, electronic properties and vibrational energies of the 1-(2-pyridylazo)-2-naphthol (PAN) molecule and its complexes with Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II). Thus, IR, Raman and SERS spectra of PAN, as well as the SERS spectrum of the Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II) complex of PAN, were assigned using DFT calculations with the hybrid B3LYP exchange-correlation functional using the standard 6-31G(d) basis set. The experimental vibrational bands were assigned to the calculated normal modes and a very good correlation was achieved between the experimental and theoretical data. The SERS spectra of PAN and of its metal chelates were recorded using HeNe laser emitting at 633 nm and hydroxylamine reduced silver colloid [1]. PAN complexes with Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II) are differentiated by their SERS spectra, each metal complex showing a particular SERS spectral fingerprint. The molecular electrostatic potential of the molecules has been calculated and used for predicting site candidates of electrophilic attack. Key words: Metal chelating compounds, heavy metal ion, FTIR, FT-Raman, SERS, DFT, 1-(2-pyridylazo)-2-naphthol (PAN). Acknowledgement: This work was supported by CNCSIS –UEFISCSU, project number PNII – RU PD_445/2010. Experimental techniques FT-IR/ATR The FTIR/ATR spectrum of PAN powder sample was recorded at room temperature on a conventional Equinox 55 (Bruker Optik GmbH, Ettlingen, Germany) FTIR spectrometer equipped with a DTGS detector. FT-Raman The FT-Raman spectrum of PAN was recorded in a backscattering geometry with a Bruker FRA 106/S Raman accessory equipped with a nitrogen cooled Ge detector. The 1064 nm Nd:YAG laser was used as excitation source, and the laser power measured at the sample position was 300 mW. The FT-Raman and FTIR/ATR spectra were recorded with a resolution of 4 cm -1 by co-adding 32 scans. SERS SERS spectra were recorded using a DeltaNu Advantage 633 Raman spectrometer (DeltaNu, Laramie, WY) equipped with a HeNe laser emitting at 633 nm. The laser power was 4 mW and the spectral resolution of 10 cm -1 . For all SERS measurements 25 µl of analyte were added to 0.5 ml silver colloid. All chemicals used were of analytical reagent grade. The silver colloid was prepared according to the previously reported procedure [1] . The pH value of the silver colloid, measured immediately after preparation, was found to be 8. PAN complexes with Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II) were prepared by adding 1 ml dilutions of 10 -3 M metal salt solution to 2 ml 10 -3 M PAN solution, up to obtaining finally 3 ml mixtures at 2:1 PAN:metal salt molar ratio, PAN chelating metal ions at 2:1 ratio. [1] N. Leopold, B. Lendl, J. Phys. Chem. B 107 (2003) 5723. Computational methods DFT exchange-correlation functionals: B3LYP & BLYP, basis sets: “spectroscopic” 6-31G(d) Optimized chemical structure of PAN with atom numbering scheme. FTIR/ATR spectra of PAN 800 1000 1200 1400 1600 648 670 734 756 786 810 858 873 911 964 985 1034 1066 1093 1116 1136 1191 1218 1252 1279 1313 1379 1408 1457 1467 1496 1524 1586 1691 1620 1606 1592 1568 1554 1502 1472 1453 1438 1402 1334 1320 1298 1262 1253 1230 1201 1157 1144 1135 1109 1098 1091 1045 1036 989 984 954 867 841 796 770 750 728 690 657 Absorbance (a.u.) Wavenumber /cm -1 PAN_FT-IR/ATR Calculated IR spectrum SERS, FT-Raman and Calculated Raman spectra of PAN 381 480 603 655 679 728 754 855 877 908 984 1002 1016 1050 1092 1153 1181 1229 1255 1310 1330 1357 1386 1433 1449 1477 1550 1574 1592 1609 1714 1619 1604 1592 1578 1554 1512 1482 1453 1441 1396 1353 1333 1321 1299 1281 1262 1252 1228 1201 1100 1090 984 906 896 856 784 761 727 706 644 600 586 569 551 539 522 499 460 449 422 369 349 315 302 252 223 261 317 354 425 463 501 529 553 608 648 734 779 810 859 911 964 1034 1116 1140 1217 1280 1379 1437 1496 1523 1550 1585 1615 1691 200 400 600 800 1000 1200 1400 1600 Raman Intensity Wavenumber (cm -1 ) SERS_PAN FT-Raman_PAN Calculated Raman spectrum Optimized chemical structure of Mn(PAN) 2 complex Conclusions PAN was investigated by experimental (FT-IR, FT-Raman and SERS) techniques in conjunction with DFT quantum chemical calculations. In order to assess the detection potential of different metal ions PAN as chelating agent and SERS as detection method, SERS spectra of different metal complexes of this ionophores were recorded (Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II), Pb(II)) using a silver colloid substratum. Each PAN-metal complex SERS spectrum shows a characteristic spectral fingerprint. Because all PAN-metal compounds indicated standard marker bands, SERS method may be a new detection technique for Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II). For PAN, DFT calculation were made for a good geometric optimization, for the molecular electrostatic potential determination and also for band assignment. B3LYP/6-31G(d) calculated 3D electrostatic potential contour map of PAN, in atomic units. 236 382 481 606 660 730 856 985 1051 1094 1154 1226 1256 1310 1333 1388 1434 1479 1551 1574 1594 1611 409 454 513 538 570 649 761 856 912 1022 1096 1142 1232 1254 1334 1361 1454 1562 1590 1612 234 476 588 644 729 758 856 909 984 1016 1093 1154 1229 1255 1330 1356 1450 1478 1551 1594 455 482 603 654 679 730 760 810 856 911 984 1017 1094 1155 1232 1252 1326 1360 1449 1477 1551 1605 454 506 568 644 756 859 908 1016 1092 1138 1231 1329 1354 1449 1511 1560 1606 452 509 586 645 758 856 909 1018 1093 1140 1230 1326 1358 1450 1508 1560 1606 238 480 604 645 729 855 984 1016 1093 1154 1229 1255 1330 1357 1385 1450 1478 1551 1605 445 477 559 587 638 729 757 856 1000 1092 1154 1230 1255 1327 1447 1478 1551 1592 200 400 600 800 1000 1200 1400 1600 Raman Intensity Raman shift /cm -1 SERS-Al(PAN) 2 SERS-Ca(PAN) 2 SERS-Pb(PAN) 2 SERS-Zn(PAN) 2 SERS-Mn(PAN) 2 SERS-Fe(PAN) 2 SERS-Cu(PAN) 2 SERS-PAN SERS spectra of PAN and PAN-metal complexes 232 276 320 367 403 426 452 518 548 596 663 697 722 754 777 879 909 929 964 986 1007 1165 1207 1243 1266 1312 1399 1424 1466 1499 1529 1574 221 261 317 354 425 463 529 553 608 648 734 779 810 858 911 964 1034 1116 1139 1217 1280 1379 1437 1496 1523 1585 1691 211 250 296 364 445 526 572 649 671 876 975 1033 1096 1127 1232 1262 1296 1343 1434 1550 1593 263 325 353 416 467 575 615 677 783 885 933 1007 1075 1150 1205 1232 1289 1326 1383 1446 1497 1532 1575 200 237 270 300 324 516 569 606 782 996 1101 1135 1199 1260 1322 1398 1437 1536 1590 197 220 271 316 378 440 533 578 656 672 749 773 879 983 1029 1096 1125 1168 1238 1274 1311 1350 1438 1552 1591 229 309 368 446 510 576 652 673 771 878 981 1041 1096 1126 1166 1230 1277 1307 1353 1440 1469 1556 1594 224 294 378 437 497 519 568 627 649 668 878 973 1000 1032 1099 1124 1149 1232 1271 1297 1338 1436 1540 1594 200 400 600 800 1000 1200 1400 1600 Pb(PAN) 2 Cu(PAN) 2 Fe(PAN) 2 Mn(PAN) 2 Ca(PAN) 2 Al(PAN) 2 Zn(PAN) 2 PAN Raman Intensity Raman shift /cm -1 Calculated Raman spectra of PAN and PAN-metal complexes B3LYP/6-31G(d) calculated 3D electrostatic potential contour map of Mn(PAN) 2 complex, in atomic units. Picture of solutions of different PAN-metal complexes: PAN Al(PAN) 2 Ca(PAN) 2 Mn(PAN) 2 Fe(PAN) 2 Cu(PAN) 2 Zn(PAN) 2 Pb(PAN) 2
Transcript

SERS, Raman, IR and DFT investigation of 1-(2-pyridylazo)-2-naphthol and its metal complexes

L. Szabó1*, K. Herman1, N. Leopold1, A. Fălămaş1, N. Mircescu1, C. Buzumurgă2, V. Chiş1

1Faculty of Physics, Babeş-Bolyai University, Kogalniceanu 1, 400084 Cluj-Napoca, Romania 2 “Nicolae Stăncioiu" Heart Institute, Moţilor 19-21, 400001 Cluj-Napoca, Romania

*[email protected] Abstract Metal ions determination represents an area of interest in several fields, like environmental protection, food safety or clinical diagnostics. Analytical methodologies for direct determination of metal ions were established over the last decades

including atomic absorption or emission spectroscopy and mass spectrometry. Although these methods are sensitive and accurate, they require tedious sample pre-treatment and expensive equipment. Thus, a significant increase in the

development of optical chemical sensors for heavy metals has been noted in the last years, aiming to their routinely production, low cost, high selectivity and sensitivity. In this work, IR, Raman and SERS spectroscopy is used in conjunction with

quantum chemical calculations in order to characterize the molecular structure, electronic properties and vibrational energies of the 1-(2-pyridylazo)-2-naphthol (PAN) molecule and its complexes with Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and

Pb(II). Thus, IR, Raman and SERS spectra of PAN, as well as the SERS spectrum of the Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II) complex of PAN, were assigned using DFT calculations with the hybrid B3LYP exchange-correlation

functional using the standard 6-31G(d) basis set. The experimental vibrational bands were assigned to the calculated normal modes and a very good correlation was achieved between the experimental and theoretical data. The SERS spectra of

PAN and of its metal chelates were recorded using HeNe laser emitting at 633 nm and hydroxylamine reduced silver colloid [1]. PAN complexes with Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II) are differentiated by their SERS spectra,

each metal complex showing a particular SERS spectral fingerprint. The molecular electrostatic potential of the molecules has been calculated and used for predicting site candidates of electrophilic attack.

Key words: Metal chelating compounds, heavy metal ion, FTIR, FT-Raman, SERS, DFT, 1-(2-pyridylazo)-2-naphthol (PAN).

Acknowledgement: This work was supported by CNCSIS –UEFISCSU, project number PNII – RU PD_445/2010.

Experimental techniques FT-IR /ATR The FTIR/ATR spectrum of PAN powder sample was recorded at room temperature on a conventional Equinox 55 (Bruker Optik GmbH, Ettlingen, Germany) FTIR spectrometer equipped with a DTGS detector. FT-Raman The FT-Raman spectrum of PAN was recorded in a backscattering geometry with a Bruker FRA 106/S Raman accessory equipped with a nitrogen cooled Ge detector. The 1064 nm Nd:YAG laser was used as excitation source, and the laser power measured at the sample position was 300 mW. The FT-Raman and FTIR/ATR spectra were recorded with a resolution of 4 cm-1 by co-adding 32 scans. SERS SERS spectra were recorded using a DeltaNu Advantage 633 Raman spectrometer (DeltaNu, Laramie, WY) equipped with a HeNe laser emitting at 633 nm. The laser power was 4 mW and the spectral resolution of 10 cm-1. For all SERS measurements 25 µl of analyte were added to 0.5 ml silver colloid. All chemicals used were of analytical reagent grade. The silver colloid was prepared according to the previously reported procedure [1]. The pH value of the silver colloid, measured immediately after preparation, was found to be 8. PAN complexes with Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II) were prepared by adding 1 ml dilutions of 10-3 M metal salt solution to 2 ml 10-3 M PAN solution, up to obtaining finally 3 ml mixtures at 2:1 PAN:metal salt molar ratio, PAN chelating metal ions at 2:1 ratio.

[1] N. Leopold, B. Lendl, J. Phys. Chem. B 107 (2003) 5723. Computational methods DFT exchange-correlation functionals: B3LYP & BLYP, basis sets: “spectroscopic” 6-31G(d)

Optimized chemical structure of PAN with atom numbering scheme.

FTIR/ATR spectra of PAN

800 1000 1200 1400 1600

648

670

734 75

6 786

810 85

887

391

1 964

985

1034

1066

1093

1116

1136

1191

1218

1252

1279

1313

1379

1408

1457

1467

1496

1524

1586 1691

1620

1606

159215

6815

54

1502

1472

1453

1438

1402

1334

1320

129812

6212

5312

3012

0111

5711

4411

3511

09109

810

9110

4510

3698

998

495

4

867

841

796

770

750

728

690

657

Abso

rban

ce (a

.u.)

Wavenumber /cm-1

PAN_FT-IR/ATR

Calculated IR spectrum

SERS, FT-Raman and Calculated Raman spectra of PAN

381

480 60

3

655

679

728

754

855

877

908

984

1002

1016

1050

1092

1153

1181

1229

1255

1310

1330

1357

1386

1433

1449

1477

1550

1574

1592 16

09

1714

161916

0415

9215

781554

1512

1482

1453

1441

1396

1353

1333

1321

1299

128112

6212

5212

2812

01

1100

1090

984

906

89685

6

784

761

727

706

644

60058

656

955

153

952

249

946

044

9422369

349

315

302

252

223

261

317

354

425

463 501 529

553 60

8 648

734

779

810

859

911

964

1034

1116 11

40

1217 12

80

1379 14

37

1496

1523

1550

1585

1615

1691

200 400 600 800 1000 1200 1400 1600

Ram

an In

tens

ityWavenumber (cm-1)

SERS_PAN

FT-Raman_PAN

Calculated Raman spectrum

Optimized chemical structure of Mn(PAN)2 complex

Conclusions PAN was investigated by experimental (FT-IR, FT-Raman and SERS) techniques in conjunction with DFT quantum chemical calculations. In order to assess the detection potential of different metal ions PAN as chelating agent and SERS as detection method, SERS spectra of

different metal complexes of this ionophores were recorded (Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II), Pb(II)) using a silver colloid substratum. Each PAN-metal complex SERS spectrum shows a characteristic spectral fingerprint. Because all PAN-metal compounds indicated standard

marker bands, SERS method may be a new detection technique for Al(III), Ca(II), Mn(II), Fe(III), Cu(II), Zn(II) and Pb(II). For PAN, DFT calculation were made for a good geometric optimization, for the molecular electrostatic potential determination and also for

band assignment.

B3LYP/6-31G(d) calculated 3D electrostatic potential contour map of PAN, in atomic units.

236

382

481

606

660

730

856

985

1051 10

94 1154 12

26 1256

1310

1333

1388

1434

1479

1551

1574

1594

1611

409 45

4

513

538

570

649

761

856

912

1022

1096

1142

1232

1254

1334

1361

1454

1562 1590

1612

234

476 588

644

729

758 85

690

9

984

1016

1093

1154

1229

1255

1330

1356

1450 14

78

1551

1594

455

482

603 654

679 73

076

081

0 856

911

984

1017

1094

1155

1232

1252

1326 13

60

1449 14

77

1551

1605

454

506

568

644 75

6

859

908

1016

1092

1138

1231

1329

1354

1449

1511

1560 1606

452

509 58

6

645

758

856

909

1018

1093

1140

1230

1326

1358

1450

1508 15

60 1606

238

480

604

645

729

855 98

410

16

1093 1154

1229

1255

1330

1357

1385

1450

1478

1551

1605

445

477 55

958

763

8 729

757

856 1000

1092

1154

1230

1255

1327

1447

1478

1551

1592

200 400 600 800 1000 1200 1400 1600

Ram

an In

tens

ity

Raman shift /cm-1

SERS-Al(PAN)2

SERS-Ca(PAN)2

SERS-Pb(PAN)2

SERS-Zn(PAN)2

SERS-Mn(PAN)2

SERS-Fe(PAN)2

SERS-Cu(PAN)2

SERS-PAN

SERS spectra of PAN and PAN-metal complexes

232

276

320

367

403

426

452

518

548

596

663

697

722

754

777

879

909

929

964

986

1007

1165 12

0712

43 1266

1312

1399

1424

1466

1499

1529 15

74

221 26

131

735

4

425

463 52

955

3 608 648

734

779

810

858

911 96

4

1034

1116 1139

1217 12

80

1379 14

3714

9615

2315

85

1691

211

250

296

364

445

526 572

649

671

876

975

1033

1096

1127

1232

1262

1296 13

43

1434

1550 15

93

263

325

353

416 467 57

561

567

7

783

885 933

1007

1075 11

5012

0512

3212

8913

2613

83

1446 1497

1532

1575

200

237

270

300

324

516

569

606

782 99

6

1101

1135

1199

1260

1322

1398 14

37

1536 15

90

197

220

271

316

378

440

533

578

656

672

749

773

879 98

310

29

1096

1125

1168

1238

1274 13

11 1350

1438

1552

1591

229

309

368

446

510 576

652

673

771

878

981

1041

1096

1126

1166

1230

1277 13

07 1353

1440

1469

1556

1594

224

294

378

437

497

519

568

627

649

668

878

973

1000

1032

1099

1124

1149

1232

1271

1297

1338

1436

1540

1594

200 400 600 800 1000 1200 1400 1600

Pb(PAN)2

Cu(PAN)2

Fe(PAN)2

Mn(PAN)2

Ca(PAN)2

Al(PAN)2

Zn(PAN)2

PAN

Ram

an In

tens

ity

Raman shift /cm-1

Calculated Raman spectra of PAN

and PAN-metal complexes B3LYP/6-31G(d) calculated 3D

electrostatic potential contour map of Mn(PAN)2 complex, in atomic units.

Picture of solutions of different PAN-metal complexes: PAN Al(PAN)2 Ca(PAN)2 Mn(PAN)2 Fe(PAN)2 Cu(PAN)2 Zn(PAN)2 Pb(PAN)2

Recommended