Cost-effective solution to server rack fire protection. Use as stand alone system or as a supplemental system with a total flood system.
Popular Tags:
26
Server Rack Fire Protection Raise your Fire Protection to a New Level Raise your Fire Protection to a New Level Firetrace Firetrace
Transcript
Page 1: Server Rack Fire Protection

Server Rack Fire Protection

Raise your Fire Protection to a New Level Raise your Fire Protection to a New Level

FiretraceFiretrace

Page 2: Server Rack Fire Protection

In-Cabinet Fire ProtectionIn-Cabinet Fire Protection

Page 3: Server Rack Fire Protection

Discharge Nozzle Created by Discharge Nozzle Created by FlamesFlames

The Firetrace Detection Tubing is a linear pneumatic fire/heat

detector and discharge nozzle on a Direct Low Pressure System

The Firetrace Detection Tubing is a linear pneumatic fire/heat

detector and discharge nozzle on a Direct Low Pressure System

Page 4: Server Rack Fire Protection

Features and BenefitsFeatures and Benefits

Page 5: Server Rack Fire Protection

Raise your LevelLevel of Fire Protection

Page 6: Server Rack Fire Protection

In-Cabinet Level Fire Protection

Room Level Fire Protection

Building Level Fire Protection

Raise your LEVELLEVEL of Protection

Page 7: Server Rack Fire Protection

Critical Advantage – Our Firetrace Critical Advantage – Our Firetrace Detection Tubing!Detection Tubing!

Flexible Tubing Flexible Tubing – allows us to provide detection and suppression almost anywhere

Rapid Detection Rapid Detection - In most instances it detects and suppresses the fire in less than 10 seconds

Cost Effective Cost Effective and easy to install on new or existing cabinets or enclosures

Flexible Tubing Flexible Tubing – allows us to provide detection and suppression almost anywhere

Rapid Detection Rapid Detection - In most instances it detects and suppresses the fire in less than 10 seconds

Cost Effective Cost Effective and easy to install on new or existing cabinets or enclosures

Page 8: Server Rack Fire Protection

Burnt CabinetBurnt Cabinet

Dramatically reduce your damage and costs to a singlesingle component or cabinet

Page 9: Server Rack Fire Protection

Detection and Suppression at the Detection and Suppression at the ignition pointignition point

Seat of Fire in Cable Bundle caused by loose connection/arcing

Tube Burst Point - showing the suppression agent was delivered straight onto the heart of the fire

Page 10: Server Rack Fire Protection

ApplicationsApplications

Page 11: Server Rack Fire Protection

Electrical and Machinery ControlElectrical and Machinery Control CabinetsCabinets

Protect each cabinet on an individualindividual basis

Page 12: Server Rack Fire Protection

Electrical and Machinery Control Electrical and Machinery Control CabinetsCabinets

Protect each cabinet on a groupedgrouped basis with one system

Page 13: Server Rack Fire Protection

Electrical ApplicationsElectrical Applications

Electrical EnclosuresTransformersSwitchgearGeneratorsUPS SystemsPower VaultsCable Trays

Page 14: Server Rack Fire Protection

Fire Alarm Panels

Building Management Systems

Auxiliary Controls

Equipment Shut Downand more…

Pressure SwitchInterfaces with…

Page 15: Server Rack Fire Protection

Protect Multiple CabinetsProtect Multiple Cabinets

One Firetrace system can protect multipleelectrical or machinery control cabinets

Page 16: Server Rack Fire Protection

Protect Mission Critical FacilitiesProtect Mission Critical Facilities

Page 17: Server Rack Fire Protection

Mission Critical FacilitiesMission Critical Facilities

Military InstallationsPower PlantsData CentersCommand and Control CentersEmergency Management CentersResearch FacilitiesPortable Data Centers

Page 18: Server Rack Fire Protection

Remote Location Fire ProtectionRemote Location Fire Protection

Page 19: Server Rack Fire Protection

Identify critical equipment and processes

Type of Fire (Class)Type of AgentType of System (Direct or Indirect)Volume of Area

Easy Installation and MaintenanceInstalls in, on or near the enclosure

Pre-Engineered SystemsPre-Engineered Systems

Page 20: Server Rack Fire Protection

Direct Low Pressure SystemDirect Low Pressure System

Tubing is both the fire/heat detector and the fire suppression delivery system, rupturing at 212 degrees Fahrenheit

Page 21: Server Rack Fire Protection

Indirect Low Pressure SystemIndirect Low Pressure System

Firetrace tubing detects the fire and the suppressant agent discharges by separate piping

Page 22: Server Rack Fire Protection

Suppression AgentsSuppression Agents

Clean Agent FM-200, FE-13, FE-25, FE 36, Novec 1230

Dry Chemical ABC, BC, D (metals), D (lithium)

Other CO2 and Foam

Page 23: Server Rack Fire Protection

Micro-Environment Fire ProtectionMicro-Environment Fire Protection

Extremely cost effectiveSupplemental to total room flooding and

sprinkler systemsNo delay in the build up of an

extinguishing concentrationAdditional level(s) of protectionAbility to protect assets that were

previously unprotectable!

Page 24: Server Rack Fire Protection

System AccessoriesSystem Accessories

Manual Release (Double Action)Pressure Switch (Cylinder and EOL)Solenoid ValveSmoke DetectorAudible AlarmTime DelaysAnd more…

Page 25: Server Rack Fire Protection

Electrical Fires

With a Firetrace Automatic Fire Detection and Suppression System…

This fire would already be out!