1348314-2A-B 1 BEFORE YOU BEGIN All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. Please leave these instructions for the consumer. They contain important information. NOTES: 1. Minimum supply pressures: 0.05MPa(0.5bar). 2. Recommended supply static pressures: 0.3MPa(3bar) on hot and cold water. 3. Supply pressure greater than 0.5MPa(5bar): install a pressure reducer. 4. Hot water temperatures, minimum: 50ºC, maximum:80ºC. 5. Recommended hot water temperature: 65ºC(energy-saving). 6. Setting range, approximately: 20ºC to 49ºC. 7. Safety stop at: 37ºC. 8. Maximum mixed water temperature: 49ºC. 9. The highest environment temperature for handshower & showerhead is 60ºC. Please keep handshower, showerhead and shower arm away from heater, or it may become damaged and cause injury to the user. HANDLE OPERATION 1348314-2A-B 4 INSTALLATION INSTRUCTIONS PARALLEL PARALLEL ROUGH-IN DIMENSIONS SERVICE PARTS The temperature is set by slowly turning the temperature selector(right-hand handle). For safety reasons, there is a stop that limits temperature to 37ºC. To get a higher temperature, push the button and continue turning the temperature selector counter-clockwise. Water flow is set by turning the left-hand handle. For 23523T-9, turn the left-handle clockwise for bath spout, turn counter-clockwise for handshower. For 23522T-9, turn the left-handle counter-clockwise for opening the faucet, turn clockwise for closing the faucet. 23523T-9 Wall Mount Thermostatic Bath Shower Faucet 23522T-9 Wall Mount Thermostatic Shower Only Faucet **Color code must be specified when ordering. 23523T-9 Wall Mount Thermostatic Bath Shower Faucet 23522T-9 Wall Mount Thermostatic Shower Only Faucet 3008304 3010697** 870992 1332248** 3010698 3021191 3019692 1228257 1170944** 831752 1240275 1244434 871616 837192 832940 1338098** 1338172** 1338096** 1240267 864922** 870721 3004741 1240267 1338099** 837192 832940 1338172** 864922** 870721 23523T: 3020067 23523T:870921 23523T:1167317 23522T:1115961 23523T:1245321 23523T:870781 23523T:1364020 23523T:1246465 831416 1248781** 77420 1030624 1240266 1236560** 1241565** 1061576 1208172 1081607 1208174** 66 G1/2˝ 75~85 G1/2˝ 150±15 66 311 85 33 51 58 28 Ø7 260 Ø110 G1/2˝ 249 150±15 66 311 10º 88~98 91 G1/2˝ 66 G1/2˝ 1500 G1/2˝ G1/2˝ 23523T-9 23522T-9
Transcript
Page 1: SERVICE PARTS PARALLEL INSTALLATION ...resources.kohler.com/plumbing/kohlerapac/pdf/23523T-9...1348314-2A-B 2 1348314-2A-B 3 CLEANING INSTRUCTIONS All Finishes: Clean the finish with

1348314-2A-B 1

BEFORE YOU BEGINAll information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.

Please leave these instructions for the consumer. They contain important information.

NOTES:1. Minimum supply pressures: 0.05MPa(0.5bar).2. Recommended supply static pressures: 0.3MPa(3bar) on hot and cold water.3. Supply pressure greater than 0.5MPa(5bar): install a pressure reducer.4. Hot water temperatures, minimum: 50ºC, maximum:80ºC.5. Recommended hot water temperature: 65ºC(energy-saving).6. Setting range, approximately: 20ºC to 49ºC.7. Safety stop at: 37ºC.8. Maximum mixed water temperature: 49ºC.9. The highest environment temperature for handshower & showerhead is 60ºC. Please keep handshower, showerhead and shower arm away from heater, or it may become damaged and cause injury to the user.

HANDLE OPERATION

1348314-2A-B 4

INSTALLATION INSTRUCTIONS PARALLELPARALLEL

ROUGH-IN DIMENSIONS

SERVICE PARTS

The temperature is set by slowly turning the temperature selector(right-hand handle). For safety reasons, there is a stop that limits temperature to 37ºC. To get a higher temperature, push the button and continue turning the temperature selector counter-clockwise. Water flow is set by turning the left-hand handle.For 23523T-9, turn the left-handle clockwise for bath spout, turn counter-clockwise for handshower.For 23522T-9, turn the left-handle counter-clockwise for opening the faucet, turn clockwise for closing the faucet.

23523T-9 Wall Mount Thermostatic Bath Shower Faucet23522T-9 Wall Mount Thermostatic Shower Only Faucet

**Color code must be specified when ordering.

23523T-9 Wall Mount Thermostatic Bath Shower Faucet23522T-9 Wall Mount Thermostatic Shower Only Faucet

30083043010697**

870992

1332248**

3010698

3021191

3019692

1228257

1170944**

831752

1240275

1244434871616

837192832940

1338098**

1338172**

1338096**

1240267

864922**

870721

30047411240267

1338099**837192

8329401338172**

864922**

870721

23523T:302006723523T:870921

23523T:1167317

23522T:1115961

23523T:1245321

23523T:87078123523T:1364020

23523T:1246465

831416

1248781**

7742010306241240266

1236560**

1241565** 1061576

1208172

1081607

1208174**

66 G1/2˝

75~85G1/2˝

150±

15

66

311

85

33

51

58 28Ø

7

260

Ø110

G1/2˝

249

150±

15

66

311

10º

88~98

91

G1/2˝

66 G1/2˝

1500

G1/2˝

G1/2˝

23523T-9 23522T-9

Page 2: SERVICE PARTS PARALLEL INSTALLATION ...resources.kohler.com/plumbing/kohlerapac/pdf/23523T-9...1348314-2A-B 2 1348314-2A-B 3 CLEANING INSTRUCTIONS All Finishes: Clean the finish with

1348314-2A-B 2

1348314-2A-B 3

CLEANING INSTRUCTIONSAll Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings.

CARE AND MAINTENANCEINSTALLATION

How to Install the FaucetTo perform installation, installer must provide G1/2˝ female supply fittings, spaced 150mm apart and horizontally. The supply fittings should be vertical and not beyond the finished wall. Hot supply pipe must be located on the left. Flush the water supply pipes thoroughly to remove debris.

Use appropriate thread sealants or thread tape on the threads of offset connectors(1). Install two offset connectors into the hot and cold supply pipes. Adjust the center-to-center distance between the connectors to 150mm and horizontally. They should extend 32 to 42mm beyond the finished wall.

Put the filters(2) into the connectors(1). Apply a ring of putty on back of the escutcheons(3). Install the escutcheons onto the supply nuts(4). Thread the supply nuts onto the connectors and tighten by strap wrench. Push the escutcheons until against the finished wall. Remove any excess putty.

How to Install the HandshowerRemove the guard on the outlet connector firstly.

Put the check valve(5) and restrictor(6) into the handshower(7) if needed.

Put the screen washer(8) into the hose(9) connector. Connect the connector(10) and handshower with hose. Tighten all the connectors.

INSTALLATION CHECKOUTEnsure all coupling nuts are tight. Ensure the handles are in the off position.Turn on the main water supply, and check for leaks. Repair as needed.

For 23523T, remove the handshower. Remove the aerator by coin. Run hot and cold water through the faucet about one minute to remove any debris. Check for leaks. Remove any debris from the aerator. Shut off the faucet, reinstall the aerator and handshower.

For 23522T, remove the handshower. Run hot and cold water through the faucet about one minute to remove any debris. Check for leaks. Shut off the faucet, reinstall the hanshower.

Round mark

Groove

NotchStop pin

Verification and SettingMake sure that the water feeds of the faucet have reach their highest temperature by letting the water run sufficiently. With the selector in position 37ºC, the temperature of the water coming out of the faucet must be within a range of 36ºC and 38ºC, as measured by a thermometer. If this is not the case, the installer can adjust the setting. Proceed with the setting as follows:

Remove the handle plug. Uninstall the screw with screwdriver(Do not lose the washer). Remove the handle kit.

With the faucet on “cold” normal water flow, slowly turn the temperature selector (always in the same direction) until water at 37ºC is obtained. If the temperature goes over 38ºC, go back to the “cold” setting and set again. When the temperature is stabilized, without turning the cartridge spindle. Make sure the bulge of the bearingalign with the groove of the body. Insert the bearing. Install the temperature handle. Ensure the upper surface of temperature handle is aligned with the faucet body. Tighten the screw with the washer. Install the handle plug.

How to Clear the FilterThe filters(2) protecting the faucet device may get obstructed and reduce water flow. When this happens, take out the filters in the connectors(1) after removing the faucet.Clean the filters by soaking them in warm vinegar. Reinstall them as the figure.

NOTE: Do not turn the cartridge when reinstall it. If you turned it without carefully, you should adjust it and be sure that the round mark is correctly in line with the groove, or readjust as per the steps of verification and setting.

Install the bearing(without turning the spindle). Make sure the bulge of the bearing align with the groove of the body. Install the handle. Ensure the upper surface of temperature handle is aligned with the faucet body. Tighten the screw with the washer. Install the handle plug.

Fig.5 Fig.6

After cleaning, install the “stop assembly” back on the cartridge, adjusting the stop pin into the notch.

Install the assembly cartridge and stop in the body, adjusting the stop pin into the notch.

Ensure the upper surface of tempera-ture handle is aligned with the faucet body before your action. Uninstall the handle kit.

Unscrew the nut and stopper. Remove the cartridge cautiously. Clean the thermostatic cartridge by soaking it in warm vinegar.

Fig.1 Fig.2

Fig.4

Fig.3

How to Clear the Thermostatic CartridgeVery hard water can obstruct filters on the thermostatic cartridge and reduce water flow. Please clean the cartridge as follows: Shut off the water supply of the faucet and open the water flow handle, then proceed to remove the cartridge. The cartridge is sensitive part, please be careful.

③②

11

12

13

14

1615

How to Install the BracketDetermine a suitable location on the finished wall to install the bracket, avoiding buried cables and pipes in the wall.

Mark mounting locations of the bracket base(12) on the wall according to the dimension. Drill two holes vertically in the finished wall according to the anchors(11) diameter. Install the anchors. Tighten screws(13) to fix bracket base on the finished wall. NOTE: The direction of the bracket base should be shown in below figure.

Loosen the screw(16) in the bottom of the bracket(14) with the hex wrench(15) so that the bracket can be installed. Apply a ring of plumbers putty or other sealants around the underside of the bracket. Put the bracket onto the bracket base and lock them by screw and hex wrench. Remove any excess putty.

Nut

Cartridge

Stopper

21

1Hot

Cold

150mm

32~42mm

Hot

Cold

7

568

9

10

32

1

4

ButtonSpindle

BearingHandle

Handle plug

Screw

Washer

NotchStop pin


Recommended