SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) & KSAL1 (Fortis plus)
Transcript
Page 1: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

SERVISNI PRIRUČNIK

(engleski)

KSAL (Fortis)&

KSAL1 (Fortis plus)

Page 2: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

Product Specification……………………..1 Refrigeration Diagram……………………..3 Wiring Diagram…………………………….6

CONTENTS

Page 3: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

1

1.1 Photo of Product

Chapter 1 Product Specification

Outdoor Unit

Indoor Unit

Page 4: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

2

1.2 Outline Dimensions

Indoor Unit

Outdoor Unit

MODEL 9000BTU 12000BTU 18000BTU

W mm 800 800 970

D mm 300 300 315

H mm 198 198 235

MODEL 9000BTU 12000BTU 18000BTU

W mm 720 760 802

D mm 260 260 298

H mm 540 540 535

Page 5: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

3

2.1 Cooling Only

Steam-gas of low pressure

Liquid of low pressure Gas of high pressure (also a little gas) & temperature

Super cooled liquid of high pressure

Chapter 2 Refrigeration Diagrams

Cooling Mode

Cooling Cycle

Indoor heat exchanger (Evaporation)

Compressor (Compression)

Capillary (Throttling)

Outdoor heat exchanger (Condensation)

Page 6: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

4

2.2 Cooling & Heating

Steam-gas of low pressure

Liquid of low pressure (also a little gas)

Gas of high pressure & Super cooled liquid temperature of high pressure

Cooling Mode

Cooling Cycle

Compressor (Compression)

Outdoor heat exchanger (Condensation)

Indoor heat exchanger (Evaporation)

Capillary (Throttling)

4-way valve (Heat pump only)

Page 7: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

5

Gas of high Pressure & temperature

Super cooled liquid of low pressure

Steam-gas of low pressure Super cooled liquid of high pressure

Heating Mode

Heating Cycle

Indoor heat exchanger (Condensation)

Compressor (Compression)

Capillary (Throttling)

Outdoor heat exchanger (Evaporation)

4-way valve (Heat pump only)

Page 8: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

6

Chapter 3 Wiring Diagram

Indoor unit

Electric chart for 09/12/18K

Page 9: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

7

Outdoor unit

Electric chart for 09/12/18K

Page 10: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

8

4.1 Error Code No. Error Code Problem

1 E1 Room temperature sensor fault

2 E2 Outdoor coil temperature sensor fault

3 E3 Indoor coil temperature sensor fault

4 E4 indoor fan motor or DC motor feedback fault

5 E5 indoor & outdoor communication fault

6 F0 Outdoor DC Fan motor fault

7 F1 IPM modular fault

8 F2 PFC modular fault

9 F3 Compressor operation fault

10 F4 Exhaust Temperature sensor fault

11 F5 Compressor top cover protection

12 F6 Outdoor ambient temp sensor fault

13 F7 Over/under voltage protection

14 F8 Outdoor modular communication fault

15 F9 Outdoor E²PROM fault

16 FA Suction temperature sensor fault

Chapter 4 Troubleshooting Guide

Page 11: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

P6: Indoor Over-temperature protection in heating modeSolution:1. Restart the air-conditioner in heating mode, and observe if the indoor fan motor function well. If the Motor doesn’t work, the motor must be replaced. If the Motor works well, please check if the filter is full o dirty and if the air intake is obstructed. If yes, please clean the filter and air intake.2. If all above parts are normal, please check when the P6 error appears. If the error come out immediately when the machine starts, it’s possible the value of resistance of the tube temperature sensor or the indoor PCB has problems, please replace them one by one and test the machine.3. If the error P6 come out after the machine functions relative long time, possibly the capillary has the obstacle causing the pressure increasing.

P6: Zaštita od pregrijavanja unut. jedinice u modu grijanjaRješenje:1. Ponovo pokrenite klima uređaj u modu grijanja I promatrajte radi li motor ventilator unutarnje jedinice dobro. Ako motor ne radi, treba ga zamijeniti. Ako motor ispravno radi, provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka.

2. Ako svi gore navedeni dijelovi normalno rade, provjerite kada se pojavljuje greška P6. Ako se greška pojavljuje odmah kad uređaj počne raditi, moguće je da se radi o problemu cijevne sonde ili PCB-a. Zamijenite ih jednog po jednog I testirajte rad uređaja.

3. Ako se greška P6 pojavljuje nakon što uređaj radi dulje vrijeme, možda je bakrena kapilara začepljena što podiže pritisak.

P6 ERROR / GREŠKA

Page 12: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

Troubleshooting Guide for 09

9

4.2 1. The Foremost Inspecting Items

⑴The input voltage must be within +10% tolerance of the rated Voltage. If it

is not the case, the air-conditioner will probably not work normally.

⑵Check the connecting cord between indoor unit and outdoor unit to see if

it is properly connected. The connecting must be done according to the

wiring diagram, please also notice that even different models may have the

connecting cord of the same specification.

Please check if the marks at the connecting terminal and the marks on the

cord can match, otherwise, the air-conditioner will not work normally.

⑶If the following phenomena are found, the problem is not from the

air-conditioner itself.

12K-

Page 13: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

10

5

The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.

The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.

NO. Problems Causes

1

The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on

Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received.

2

The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.

If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.

3

The compressor works discontinuously at dehumidifying mode.

The air-conditioner will automatically control the working of the compressor according to the inside temperature

4The air-conditioner does not work while the LED display is on.

The TIMER is set with the air-conditioner; it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition

Page 14: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

11

2. No Power Display

⑴Items

a) Check if the input voltage is correct?

b) Check if the AC power supply connecting is correct?

c) Check if the output voltage of the manostat L7805 (IC2) is correct?

⑵Trouble shooting procedure

Page 15: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

12

connector (CN8)?

⑵Trouble shooting procedure

3. The Indoor Fan Motor Does Not Work

⑴Items

a) Check if the indoor fan motor is connected correctly to the connector (CN8)?

b) Check if the AC input voltage is correct?

c) Check if the IC of indoor fan motor is connected correctly to the connector

(CN2)?

d) Check if the capacity of indoor fan motor is connected correctly to the

Page 16: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

13

4. The Outdoor Unit Does Not Work

⑴Items

a) Check if the input voltage is correct?

b) Check if the wire connection of the outdoor connecting terminal is correct?

⑵Trouble shooting procedure

Page 17: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

14

5. The Step Motor Does Not Work

⑴Items

a) Check if the input voltage is correct?

b) Check if the step motor controlling the up-down movement firmly

connected to Cn2?

⑵Trouble shooting procedure

Page 18: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

15

6. Heating Mode Can Work, But No Hot Air Blow

⑴Check if the set temperature is lower than the indoor temperature?

⑵Check if the indoor PCB is connected to the terminal correctly?

Page 19: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

16

7. Remote Control Can Not Work

Trouble shooting rocedure

Page 20: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

17

8. The Failure Analysis of the Main Parts

Page 21: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

4.3 Troubleshooting Guide for 18-24K

18

1. The Foremost Inspecting Items

⑴The input voltage must be within +10% tolerance of the rated Voltage. If it

is not the case, the air-conditioner will probably not work normally.

⑵Check the connecting cord between indoor unit and outdoor unit to see if

it is properly connected. The connecting must be done according to the

wiring diagram, please also notice that even different models may have the

connecting cord of the same specification.

Please check if the marks at the connecting terminal and the marks on the

cord can match, otherwise, the air-conditioner will not work normally.

⑶If the following phenomena are found, the problem is not from the

air-conditioner itself.

Page 22: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

dehumidifying mode, and the indoor fan motor slows down.

exchanger from being frozen.

NO. Problems Causes

1The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on

Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the signal is well received.

2

The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.

If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.

3The compressor works discontinuously at dehumidifying mode.

The air-conditioner will automatically control the working of the compressor according to the inside temperature

4The air-conditioner does not work while the LED display is on.

The TIMER is set with the air-conditioner; it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition.

5

The compressor works discontinuously at cooling and

The compressor stops internally or the fan motor slows down to prevent the indoor heat

19

Page 23: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

20

2. No Power Display

⑴Items

①Check if the input voltage is correct?

②Check if the AC power supply connecting is correct?

③Check if the output voltage of the manostat L7805(IC2)is correct?

⑵Trouble shooting procedure

Page 24: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

21

3. The Indoor Fan Motor Does Not Work

⑴Items

①Check if the indoor fan motor is connected correctly to the connector(CN8)?

②Check if the AC input voltage is correct?

③ Check if the IC of indoor fan motor is connected correctly to the

connector(CN2)?

④Check if the capacity of indoor fan motor is connected correctly to the

connector(CN8)?

⑵Trouble shooting procedure

Page 25: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

22

4. The Outdoor Unit Does Not Work

⑴Items

①Check if the input voltage is correct?

②Check if the wire connection of the outdoor connecting terminal is correct?

⑵Trouble shooting procedure

Page 26: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

23

5. The Step Motor Does Not Work

⑴Items

①Check if the input voltage is correct?

②Check if the step motor controlling the up-down movement firmly connected

to Cn2?

⑵Trouble shooting procedure

Page 27: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

24

6. Heating Mode Can Work, But No Hot Air Blow

⑴Check if the set temperature is lower than the indoor temperature?

⑵Check if the indoor PCB is connected to the terminal correctly?

Page 28: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

25

7. Remote Control Can Not Work

Trouble shooting procedure

Page 29: SERVISNI PRIRUČNIK (engleski) KSAL (Fortis) KSAL1 (Fortis ... · provjerite je li filter prljav ili je neka zapreka na usisu zraka. Ako je tako, očistite filter I usis zraka. 2.

26

8. The Failure Analysis of the Main Parts


Recommended