Page 1: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

Instructions for use

Setup Wizard 5.0

Easy connectivity

with LIS/HIS

Page 2: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

2

1 INTENDED USE 3

2 SUMMARY AND EXPLANATION 3

3 CONTENTS 3

4 INSTALLATION 3 4.1 Software and hardware requirements 3 4.2 Hardware settings for the QuikRead QuikLink Setup Wizard 4 4.3 Installing the QuikRead QuikLink Setup Wizard 4 4.4 Removing the QuikRead QuikLink Setup Wizard 4

5 USING THE QUIKREAD QUIKLINK SETUP WIZARD 5 5.1 Password protection 5 5.1.1 Creating a password 5 5.1.2 Login user 5 5.1.3 Changing password 6 5.1.4 Forgotten password 6 5.2 Selecting the setup mode 7 5.3 Uploading QuikRead Instrument software 8 5.4 ConfiguringtheQuikReadInstrument 10 5.4.1 Selectingconfigurationtasks 10 5.4.2 QuikRead Instrument time and serial number setup 11 5.4.3 QuikLink operation mode setup 12 5.4.4 LIS/HIS connection setup 13 5.4.5 Bar code reader setup 13 5.4.6 Printer data transfer setup 14 5.4.7 Display timeout setup 15 5.4.8 Settings review 16 5.4.9 Configurationphase 16 5.4.10 LIS/HIScommunicationprotocoltest 17 5.4.11 Configurationcomplete 17 5.5 Finishing the QuikRead QuikLink Setup Wizard 18 5.6 QuikLink Setup Wizard maintenance 18 5.6.1 InstallQuikReadInstrumentsoftwarefiles in the QuikLink system 18 5.6.2 Undoprevioussoftwarefileinstallation 19 5.6.3 Add a new bar code reader model to the QuikLink system 19 5.6.4 Enable password protection 19

6 TROUBLESHOOTING 20

Appendix 1: Bar codes

Appendix 2: DescriptionofQuikRead101InstrumentLIS/HISoperation

QuikRead® QuikLink Setup Wizard Cat. No. 06100

INSTRUCTIONS FOR USE

Page 3: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

3

1 INTENDED USETheQuikReadQuikLink SetupWizard is used for configuring theQuikRead 101Instrument to communicate with the Laboratory or Hospital Information System (LIS/HIS).

2 SUMMARY AND EXPLANATIONQuikRead QuikLink allows transfer of QuikRead assay results coupled with patient identi-ficationtoaremoteLIS/HISusingtheRS232,andtheASTM1381and1394protocols.

The QuikRead QuikLink Setup Wizard uploads a LIS/HIS compatible QuikRead Instru-mentsoftwareversionintotheQuikReadInstrument.Itconfiguresthebarcodereaderand the LIS/HIS communication settings.

Note:After servicing theQuikRead Instrument or theDatalogic bar code reader, thedevicesneedtobereconfiguredtothecustomisedsettings.

3 CONTENTSCat.No.06100QuikRead QuikLink contains the following items:

• QuikReadQuikLinkSetupWizardCD-ROM

• QuikRead QuikLink Setup Wizard instructions for use

4 INSTALLATION4.1 Software and hardware requirementsThe minimum configuration needed for proper software operation is what is required for most Microsoft® Windows® applications:

• A PC with Windows® XP or Windows 7

• Aharddiskwith10Mboffreediskspace• Windows® XP SP 1with128MbofRAM(256recommended)

• Small font size selected on Windows® display properties

• A serial port connection

• Serialcable(nullmodem,DB9-DB9)• QuikRead QuikLink bar code reader (optional)

• QuikRead101Instrument,Cat.No.06040,06078

Page 4: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

4

4.2 Hardware settings for the QuikRead QuikLink Setup WizardThe required hardware connection is described in Figure 1.

4.3 Installing the QuikRead QuikLink Setup Wizard• Remove any existing previous versions of the QuikRead QuikLink Setup Wizard.

• InserttheQuikReadQuikLinkSetupWizardCDintotheCD-ROMdrive.

• Runthesetup.exeprogramfromtheCD-ROM.• Follow the instructions provided on the screen.

• After finishing the installation of theQuikLinkSetupWizard, select theQuikLink Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory.

4.4 Removing the QuikRead QuikLink Setup WizardSelect the Uninstall QuikLink Setup Wizard from your computer Start menu or use Add/remove programs in the Control Panel to remove the Wizard.

AC

D

B

Figure 1

Cable connection A Serial cable B Bar code reader connector C Bar code reader interface cable D Power cord

Page 5: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

5

5 USING THE QUIKREAD QUIKLINK SETUP WIZARD5.1 Password protectionPassword protection prevents unauthorized persons from making critical changes to your QuikReadInstrumentconfigurations.

5.1.1 Creating a passwordWhentheprogramisrunforthefirsttime,theWizardaskstheusertocreateapasswordor disable password protection.

• To create a password, enteryour pass word in the Enter new password field, verify itand click on OK. The password must be 4 to 30 characterslong.

• To disable password protec- tion, select theDisable login control check box and click on OK.

5.1.2 Login userIfpasswordprotectionisenabled,aLoginwindowisshowedateverystartup.

• Enter your password in the Enter password field and click on OK.

• Cancel will shut down the program.

Page 6: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

6

5.1.3 Changing passwordTochangeyourpassword,clickontheChange password hyperlink in the Login window. The Change password window is displayed.

• Enter the current password in the Enter old passwordfield.

• Enter a new password in the Enter new password field,verify it and click on OK. Your password is changed, andthe QuikLink Setup Wizard is started.

• Cancel will shut down the pro-gram.

5.1.4 Forgotten passwordIfyouforgetyourpassword,clickontheForgot your password? hyperlink in the Login window. The Forgot your password window is displayed.

• Contact your QuikRead supplier and ask for the QuikLink Setup Wizard password release key.

• Enter the password release key in the Password release keyfieldandclickonNext. The Enter new password window is displayed.

Page 7: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

7

• Enter your new password in the Enter new passwordfield,verify it and click on Next. Your password is now changed.

• To disable the password protec-tion,selecttheDo not ask me the password anymore check box and click on Next.

• Click on Finish to close this window and to start the Quik-Link Setup Wizard.

5.2 Selecting the setup modeWhentheQuikLinkSetupWizardhasbeenstarted,clickonNext on the Welcome page to enter the Setup mode selection page.

Create LIS/HIS settings – The Quik Read Instrument must have software version 5.0 or newerinstalled for using the LIS/HIS features. To make the QuikRead Instrument LIS/HIS compatible,select the Create LIS/HIS set-tings mode. The newest version of Quik Read Instrument software will be uploaded and the selected LIS/HISsettingsconfigured.

Configure the existing LIS/HIS settings – When the QuikRead Instrument already has aLIS/HIScompatiblesoftwareversion,theusercanconfiguretheinstrument’sLIS/HISsettings without having to upload a new software version.

Change the QuikRead Instrument time settings – To change only the time of the QuikRead Instrument.

QuikLink Setup Wizard maintenance – If a new QuikRead Instrument software version hasbeenreleased,itshouldbeinstalledintheQuikLinkSetupWizardforuploadingitto the QuikRead Instrument. Any changes to bar code reader models are also applied through the wizard maintenance function.

• Click on Next to enter the selected setup mode.

Page 8: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

8

5.3 Uploading QuikRead Instrument softwareNote 1: You must disconnect the bar code reader interface cable during QuikRead software uploading.

Note 2: COM1orCOM2portneedstobeused.

When the Create LIS/HIS settingsmodehas been selected,QuikRead Instrumentsoftware uploading will be performed.

On the QuikRead instrument software uploading – STEP 1 page:

• Select the serial port to which the QuikRead Instrument is connected. See Figure 1 for connection instructions.

• Click on Next to enter the next step.

On the QuikRead instrument software uploading – STEP 2 page:

• Restart the QuikRead Instru-ment if the Wizard requests for it.

• The QuikLink Setup Wizard verifies that theQuikRead In-strument does not already have a newer QuikRead software version than the one installed in the QuikLink Setup Wizard.

• After a successful software versioncheck,makesurethatRead the card is displayed by the QuikRead Instrument LCD. Click on Next to enter the next step.

• Incaseofanyerrors,seetrou-bleshooting.

Page 9: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

9

On the QuikRead Instrument software uploading – STEP 3 page:

• The user is asked to restart the QuikRead Instrument. The instrument must be restarted within20seconds tostartup-loading.

• The progress bar indicates the uploading process. Uploading takes approximately three to four minutes to perform.

• Once uploading is complete,the Wizard automatically enters the QuikRead Instrument soft ware uploading – Step 4 page.

On the QuikRead Instrument software uploading – STEP 4 page:

• Wait until the text Read the card is displayed by the QuikRead InstrumentLCD.Thefirststartafter uploading might take up to two minutes to perform.

• If the bar code reader will be used, connect the bar codereader interface cable behind the QuikRead Instrument.

• Click on Next to start the instru-ment’sLIS/HISconfigurations.

Page 10: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

10

5.4 Configuring the QuikRead Instrument5.4.1 Selecting configuration tasks

• Ensure that the QuikRead Instrument is connected via a serial cable to the computer with the QuikRead QuikLink Setup Wizard installed. See figure1.

• Select the serial port to which the QuikRead Instrument is connected.

• Select the configuration tasksfrom the Settings to be con-figured list.

Time and serial number setup – Sets the serial number and time for the QuikRead Instrument.

QuikLink operation mode setup – Selects the QuikLink operation mode for the QuikRead Instrument.

LIS/HIS connection setup–ConfigurestheserialportsettingsoftheQuikReadInstru-ment to match the LIS/HIS connection settings.

Bar code reader setup –ConfiguresthebarcodereaderandtheQuikReadInstrumentto communicate with each other.

Printer data transfer setup – Sets the QuikRead Instrument to match the printer data transfer speed.

Display timeout setup–Setsthetimeforthedisplayoftheresult,operatorIDandpatientID on the QuikRead Instrument LCD.

LIS/HIS communication protocol tests – Checks that the bar code reader has been successfullyconfiguredandthattheQuikReadInstrumentcreatestheLIS/HISmessagein a correct format. These actions are not sent to the LIS/HIS.

• Oncethenecessaryconfigurationstaskshavebeenselected,clickonNext.

Page 11: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

11

5.4.2 QuikRead Instrument time and serial number setupWhentheQuikReadInstrumenttimeandserialnumbersetuppagehasbeenentered,theQuikRead QuikLink Setup Wizard searches for the current settings from the QuikRead Instrument.

• Restart the QuikRead Instru-ment if the Wizard requests for it.

• After the search process, thecurrent settings are displayed.

• Check the QuikRead Instrument serial number at the back of the instrument. Enter the serial number in the QuikRead Instru-mentserialnumberfield.Onlynumbers are allowed.

• Enter the current time in the Current time field. Time is entered in the 24h format.

• Click on Next to continue.

Page 12: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

12

5.4.3 QuikLink operation mode setupWhen the QuikLink operation mode setuppagehasbeenentered,theQuikReadQuik-Link Setup Wizard searches for the current settings from the QuikRead Instrument.

• Restart the QuikRead Instru-ment if the Wizard requests for it.

• After the search process, thecurrent settings are displayed.

• Select the QuikLink operation mode to be used:

QuikLink mode with bar code reader–Enablespatientandoperatoridentificationwithbarcodes.TheresultscoupledwithidentificationsaretransferredtotheLIS/HISsystemoraprinter.Optionally,atemporaryNON-LISmodeisallowed.Operatoridentificationisanoptionalfeature,whichcanbeenabledordisabled.Themeasuredresultsmustbeaccepted with the bar code reader before they are sent to the LIS/HIS system or printer if the Accept result before sendingoptionisenabled.Iftheresultacceptanceisdisabled,the results are automatically sent to the LIS/HIS system.

QuikLink mode without bar code reader – The results are transferred to the LIS/HIS systemwithoutpatientandoperatoridentification.Whenthismodehasbeenselected,the bar code reader and printer data transfer setup functions are disabled.

NON-QuikLink mode–Restorestheinstrumenttonormalfactorysettings.Inthismode,patientandoperatoridentificationsaredisabledandtheresultsarenotsenttotheLIS/HIS.Whenthismodehasbeenselected,thebarcodereader,LIS/HISconnectionanddisplaytimeout setup functions are disabled.

• Click on Next to continue.

Page 13: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

13

5.4.4 LIS/HIS connection setupWhen the LIS/HIS connection setuppagehasbeenentered,theQuikReadQuikLinkSetup Wizard searches for the current settings from the QuikRead Instrument.

• Restart the QuikRead Instru-ment if the Wizard requests for it.

• After the search process, thecurrent settings are displayed.

• Select the serial port settings to be used for LIS/HIS communi-cation.

• Select the LIS/HIS data output format:

Printer format – The results are sent in a clear text format. Select this option if the re-sults are to be sent to the printer only. Note that the Printer format is enabled only in the QuikLink mode with bar code reader.

ASTM format–TheresultsaresentinanASTMformat.Thisoptionmustbeselectedwhen sending results to the LIS/HIS.

• Click on Next to continue.

Note that LIS/HIS connection setup is disabled in the NON-QuikLink mode.

5.4.5 Bar code reader setup• Restart the QuikRead Instru-

ment if the Wizard requests for it.

• Select the bar code reader mod-el from the Bar code reader model table. Supported bar code families are displayed in the list below.

• Use the bar code reader to read RESTORE DEFAULTS and RS232 bar codes in APPEN DIX 1. Once the bar codes have beenread,selectthecheckboxto enable the Next button.

• Click on Next to continue.

Note that Bar code reader setup is enabled only in the QuikLink mode with bar code reader.

Page 14: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

14

5.4.6 Printer data transfer setupWhen the Printer data transfer setuppagehasbeenentered,theQuikReadQuikLinkSetup Wizard searches for the current settings from the QuikRead Instrument.

• Restart the QuikRead Instru-ment if the Wizard requests for it.

• After the search process, thecurrent settings are displayed.

• Select printer data transfer speed matching the RS232 settings of the printer used.

• Click on Next to continue.

Note that Printer data transfer setup is disabled in the QuikLink mode without bar code reader.

Page 15: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

15

5.4.7 Display timeout setupWhen the QuikLink operation mode setuppagehasbeenentered,theQuikReadQuik-Link Setup Wizard searches for the current settings from the QuikRead Instrument.

• Restart the QuikRead Instru-ment if the Wizard requests for it.

• After the search process, thecurrent settings are displayed.

• Select the display timeout val-ues (maximum 15 seconds).

Result – Indicates the time that the measured result is displayed by the QuikRead Instrument LCD.

Patient ID–IndicatesthetimethatpatientidentificationisdisplayedbytheQuikReadInstrument LCD. Patient ID timeout selection is disabled in the QuikLink mode without bar code reader.

Operator ID–IndicatesthetimethatoperatoridentificationisdisplayedbytheQuikReadInstrument LCD. Operator ID timeout selection is disabled in the QuikLink mode without bar code reader orifoperatoridentificationisdisabled.

• Click on Next to continue.

Note that Display timeout setup is disabled in the NON-QuikLink mode.

Page 16: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

16

5.4.8 Settings reviewBeforethesettingsareconfiguredinthememoryoftheQuikReadInstrument,theyaredisplayed on the Settings review page.

• Ensure that the settings are cor-rect.Ifthereareanyerrors,clickon Back to return to previous pages and make the necessary changes.

• If the bar code reader is going tobeconfigured,thePlay but-tonfortheconfigurationsamplesound is dis played. Click on the button and the Wizard plays the sound sample that you should hear when the bar code reader isconfigured.

NOTE:Thesamplesoundmaybeslightlydifferentfromtheactualconfigurationsound.

• Oncethesettingshavebeenverifiedascorrect,clickonNexttoentertheconfiguration phase.

5.4.9 Configuration phaseOnce the settings havebeen reviewedand verifiedas correct, they are sent to theQuikRead Instrument.

• Restart the QuikRead Instru-ment if the Wizard requests for it.

• The progress bar indicates that Quik Read configuration is in process.

• OnceQuikReadhasbeenconfi-gured,themessageConfigura-tion per formed successfully. Click on Next to continue is displayed.

• Click on Next to continue.

Page 17: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

17

5.4.10 LIS/HIS communication protocol test• Restart the QuikRead Instru-

ment if the Wizard requests for it.

• Click on the Test LIS/HIS com-munication protocol button.

• Use the bar code reader to read within 15 seconds the OK/AC-CEPT bar code in APPENDIX 1,whentheWizardrequestsforit. If thetest issuccessful, themessage LIS/HIS communica-tion protocol test performed successfully is displayed.

• Click on Next to continue.

Note that LIS/HIS communication protocol test is enabled only in the QuikLink mode with bar code reader.

5.4.11 Configuration completeWhenallthenecessaryconfigurationphaseshavebeencarriedout,theConfiguration complete page is displayed.

• Check that the text Read the card is displayed by the LCD of the previously configured QuikRead Instrument. Then,disconnect the instrument.

• Configuration information is saved intoa textfile.Clickonthe Open configuration file buttontoopentheconfigurationfileintoyourdefaulttexteditor.Notethattheconfigurationfilesare located in the QuikLink Setup Wizard installation direc-tory.

• Click on Next to enter the Fin-ish page.

• Ifyouwanttoconfigureanotherinstrument without closing the Wizard, select theConfigure an other instru ment check box and click on Next. The Wizard will return to the Setup mode selection page.

Page 18: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

18

5.5 Finishing the QuikRead QuikLink Setup Wizard

• Click on Finish to close the Wizard.

5.6 QuikLink Setup Wizard maintenanceIftheQuikLinkSetupWizardmaintenancesetupmodewasselected,theMain te nance page of the Wizard will be entered. The following options are now available.

• Install QuikRead Instrument software files in theQuikLinksystem.

• Undotheprevioussoftwarefileinstallation.

• Add a new bar code reader model to the QuikLink system.

• Enable password protection.

5.6.1. Install QuikRead Instrument software files in the QuikLink systemWhena newQuikRead Instrument software version has been released, itmust beinstalled in the QuikLink Setup Wizard before it can be uploaded in the QuikRead Instru-ment.ToinstallanewQuikReadInstrumentsoftwareversion,thefollowingstepshaveto be performed:

• Check that you have received the files quikread+2.a37 and QRCRC.txt and that they are located in the same directory.

Page 19: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

19

• Click on the Install QuikRead Instrument software files into QuikLink system button. The Open file dialog appears.

• Find thequikread+2.a37 file that youhave received, select it and click onOpen. TheWizardwill now install the files.Note: you cannot select currently installed filesfromtheapplicationdirectory.

• The message QuikRead Instrument software files installed successfully into QuikLink system is displayed after successful operation.

• Incaseofanyerrors,seetroubleshooting.

5.6.2 Undo previous software file installationWhenthenewQuikReadInstrumentsoftwarefileswereinstalledtotheWizard,backupfileswerecreatedfromtheprevioussoftwarefilestobeusedforrestoring.

• Click on the Undo previous software file installation button.

• The message QuikRead Instrument software files restored successfully is displayed after successful operation.

• Incaseofanyerrors,seetroubleshooting.

5.6.3 Add a new bar code reader model to the QuikLink systemIf a bar code reader model with suitable bar code families cannot be found in the bar code reader table on the Bar code reader setuppage,contactyourlocalsupplierforanadditionalbarcodereaderconfiguration.Anewconfigurationfilewillbeprovided.

• Click on the Add new bar code reader model to QuikLink system button. The Open file dialog appears.

• FindthebarcodereaderconfigurationXMLfilethatyoureceived,selectit,andclick on Open.

• The Wizard installs the new bar code reader information in the system. The message New bar code reader added is displayed after successful operation.

• Incaseofanyerrors,seetroubleshooting.• Configureyourbarcodereaderwithappropriatesettings.

5.6.4. Enable password protectionIfpasswordprotectioniscurrentlydisabled,theEnable password protection button is displayedonthemaintenancepage.Toenablepasswordprotection,usethefollowingsteps:

• Click on the Enable password protection button. The Create password dialog is displayed.

• Follow the instructions at 5.1.1 Creating password.

Page 20: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

20

6 TROUBLESHOOTING

Error class Error type Possible cause Corrective action

QuikRead Instrument software upload

A message Cannot upload the QuikRead Instrument software from QuikLink. The QuikRead Instrument already has a software that is newer than the one included in the QuikLink Setup Wizard is displayed.

QuikRead Instrument has a newer software than the one included in the QuikLink Setup Wizard.

Uploading is not needed. Select the Configure the existing LIS/HIS settings setup mode.

Contact the QuikRead supplier for the latest version of the QuikLink Setup Wizard.

Preceding QuikRead Instrument soft-ware upload was interrupted and current software version is therefore not available.

Continue the QuikRead Instrument software upload.

An error message is displayed by the QuikRead Instrument LCD.

Several causes. Contact your local supplier.

The program does not start the uploading process.

Select another serial port and try again.

The serial cable is not connected or is of the wrong type.

Check the serial port and cable connections. Try again.

A message Software version not available. Click on Next to continue is displayed.

The user has selected the wrong serial port.

QuikRead Instrument is set into Printer mode (using9600bps).

Page 21: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

21

Error class Error type Possible cause Corrective action

The messages Connection lost and Errors during software upload. Try again are displayed. Uploading cancelled.

QuikRead Instrument was not restarted in 20secondsof time after the restart message was displayed.

Check that the serial cable is properly connected. Try again.

No connection to the QuikRead Instrument.

Check that the serial cable is properly con nected. Try again.

Check that Quik -Read is powered. Try again. Check that the bar code interface cable is disconnected during software uploading.

The messages QuikRead Instru - ment software file is corrupted and Errors during soft - ware upload. Try again are displayed. Uploading cancelled.

The QuikRead Instrument softwarefiles are corrupted.

Reinstall the QuikRead QuikLink Setup Wizard. Try again.

The message Cannot find the software files and Errors during soft-ware upload. Try again are displayed. Up-loading is cancelled.

The QuikRead Instrument soft-warefiles are missing.

Reinstall the QuikRead QuikLink Setup Wizard. Try again.

Only the message Errors during software upload. Try again is displayed.

Error in writing software data.

Check your connections and try again.

QuikRead Instrument software upload

Read the card text is not displayed by the QuikRead Instrument LCD after the software uploading process.

QuikRead Instru-ment software upload was interrupted.

Try again. Iftheerrorpersists,contact your local supplier.

Other cause.

Page 22: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

22

TROUBLESHOOTING ...

Error class Error type Possible cause Corrective action

Searching current settings from the QuikRead Instrument

Unable to establish connection between the PC and the QuikRead Instrument. The message Unable to search settings from QuikRead instrument. Check your connections and try again is displayed. The program returns to the Setup configu ration page.

The wrong serial port was selected.

Check your connections. Try again.

The serial cable is not properly connected.

The serial cable is of the wrong type.

QuikRead was not restarted within one minute after the restart message was displayed.

The message Unable to open serial port. Try again is displayed.

The selected serial port is being used by another application.

Close the appli cation using the same serial port. Try again.

Select another serial port and try again.

The program loops the progress bar for several minutes and does not react to any inputs.

Program malfunction.

Shut down the QuikRead QuikLink Setup Wizard by using the Windows Task manager. Restart the Wizard and try again.

QuikRead Instrument configuration

The message Unable to configure QuikRead Instrument. Check your connections and try again is displayed. The program returns to the Settings review page.

The serial cable is not properly connected.

Connection to QuikRead was lost.

Check your connections and try again.

Page 23: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

23

Error class Error type Possible cause Corrective action

QuikRead Instrument configuration

The message Unable to open serial port. Try again is displayed.

The serial port is being used by another application.

Close the applica tion that uses the same serial port. Try again.

The current QuikLink operation mode does not support the selected configurationtask.

The message This setting cannot be confi gured in NON-QuikLink mode or This setting can -not be configured in QuikLink mode without bar code reader is displayed.

Select another QuikLink mode or ignore the message.

LIS/HIS commu- nication protocol test

The message Unable to perform LIS/HIS communication protocol test is displayed.

The OK/ACCEPT bar code was not read within 15 seconds after the read message was given.

Try again.

The bar code reader and the QuikRead Instrument are not properly configured.

Reconfigurethe bar code reader and the QuikRead Instrument. Repeat the LIS/HIS communication protocol test.

The message Unable to perform connection to QuikRead Instrument. Select another serial port and try again is displayed.

The serial cable is not properly connected.

Check your connections and try again.

The wrong serial port was selected.

QuikRead was not restarted within one minute after the restart message was given.

The message This test cannot be performed in NON-QuikLink mode or This test cannot be performed in Quik-Link mode without bar code reader is displayed.

The current QuikLink operation mode does not support the LIS/HIS communication protocol test.

Select another QuikLink mode or ignore the message.

Page 24: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

24

Error class Error type Possible cause Corrective action

Install QuikRead Instrument software filesintheQuikLink system

The message Unable to install QuikRead Instrument software files into QuikLink system is displayed.

The new software filesarecorrupted.

The current softwarefiles are corrupted.

1.Try again.

2. If the error messages persist,contact the QuikRead supplier for new softwarefiles. Try again.

3. If the error messages persist,reinstall the QuikRead QuikLink Setup Wizard and try again.

Undo previous QuikRead Instrument softwarefileinstallation

The message Unable to restore QuikRead Instru-ment software files is displayed.

The backup filesarecorrupted.

This action cannot be performed.

Add a new bar code reader to the QuikLink system

The message Incorrect bar code reader setup file is displayed.

The bar code readersetupfileis corrupted.

The user has selected the wrongfile.

1. Ensure that you have selected the correctfile. Try again

2. If the error messages persist,contact the QuikRead supplier for a newsetupfile. Try again.

QuikRead QuikLink Setup Wizard layout

Program windows are not displayed properly. Buttons and other controls are missing.

Large fonts are in use.

Enter your display properties and set the font size as Small. Restart your computer.

TROUBLESHOOTING ...

Page 25: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

25

APPENDIX 1 Bar codes

RS232

RESTORE DEFAULTS

OK / ACCEPT

Page 26: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

26

APPENDIX 2Description of QuikRead 101 Instrument LIS/HIS OperationQuikRead101InstrumentoperationintheLIS/HISmodeisunidirectional.Themeasure-ment result is sent direct to the LIS/HIS computer after each measurement. No tests can be ordered from QuikRead.

ASTM E 1394 related informationTwo different LIS/HIS modes will be implemented

• Mode1 QuikLinkmodewithbarcodereader • Mode2 QuikLinkmodewithoutbarcodereader

In Mode 1, the following data will be sent to the LIS/HIS computer (terminologybasedonASTMstandardE1394):

1. Laboratory Assigned Patient ID (within the patient record) -sequence number 2. Instrument Specimen ID (within the order record) 3. UniversalTestID,Manufacturer’sorLocalCode(part4),(withinresultrecords) -NameoftheAnalyte(e.g.CRP,FOB) 4. DataorMeasurementValue(withintheresultrecord) -(e.g.29,POSITIVE) 5. Units (within the result record) 6. OperatorIdentification(optional,withintheresultrecord) 7. Date/Time Test Completed (within the result record) 8. Instrumentidentification(withintheresultrecord) -QUIKREAD“device-specificIDnumber”

In Mode 2, the following data will be sent to the LIS/HIS computer

1. Instrument Specimen ID (within the order record) -sequence number 2. UniversalTestID,Manufacturer’sorLocalCode(part4),(withinresultrecords) -NameoftheAnalyte(e.g.CRP,FOB) 3. DataorMeasurementValue(withintheresultrecord) -(e.g.29,POSITIVE) 4. Units (within the result record) 5. Date/Time Test Completed (within the result record) 6. Instrumentidentification(withintheresultrecord) -QUIKREAD“device-specificIDnumber”

QuikRead101InstrumentoperationintheLIS/HISmode.

User collects information for the next measurement

User starts the measurement

The result is sent to the LIS/HIS computer

Page 27: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

27

Example of a message from QuikRead to a LIS/HIS computer in Mode 1:

H|\^&<CR> P|1||12345678<CR> O|1||127<CR> R|1|^^^CRP5|71|mg/l||||||09876543||20031006154700|QUIKREAD2<CR> L|1<CR>

Example of a message from QuikRead to a LIS/HIS computer in Mode 2:

H|\^&<CR> P|1<CR> O|1||98<CR> R|1|^^^CRP5|71|mg/l||||||||20031006154700|QUIKREAD2<CR> L|1<CR>

ASTM E 1381 related information

The following communication features are valid in both LIS/HIS modes: • BaudRate9600(optionally2400,4800,14400,19200,38400bps) • One (1) start bit • TransmissionorderLSBfirst • Noparity(optionallyEven,Odd) • Eight (8) data bits (optionally 7) • One (1) stop bit (optionally 2)

Mode 2 QuikLink mode without bar code reader

[Succesful transfer]

Idle

Changing analyte

Measurement Self-check Sending result to LIS computer

Read analyte card to proceed

[Unsuccesful transfer]

IdleReading patient

ID

Reading operator

ID (optional)

[Succesful transfer]

Self- check

Accept result before

sending?

[Accept]Self-

checkMeasure-

ment

Changing analyte Normal text

for printer

Sending result to

LIS computer

Print result?

[No]

[Yes]

[Reject]

Mode 1 QuikLink mode with bar code reader

Accept-ing

result

[Yes]

[No] Unsucces- ful transfer

Page 28: Setup Wizard 5 · 2019-04-26 · Setup Wizard from your computer Start menu or double-click on the QuikLink.exe in the installed directory. 4.4 Removing the QuikRead QuikLink Setup

QR QL CD Insert 901-07

Orion Diagnostica Oy 11/2016

Orion Diagnostica Oy Koivu-Mankkaan tie 6 BP.O.Box 83, FI-02101 Espoo, FinlandTelephone +358 10 4261 Telefax +358 10 426 2794www.oriondiagnostica.comwww.quikread.com

QuikRead® is a registered trademark of Orion Diagnostica Oy.