+ All Categories
Home > Documents > Sewage Pump

Sewage Pump

Date post: 16-Nov-2014
Category:
Upload: jvossler
View: 474 times
Download: 0 times
Share this document with a friend
11
SUBMERSIBLE SEWAGE PUMP 66119 SET UP AND OPERATING INSTRUCTIONS Distributed exclusively by Harbor Freight Tools ® . 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. Copyright © 2008 by Harbor Freight Tools ® . All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included. For technical questions or replacement parts, please call 1-800-444-3353.
Transcript
Page 1: Sewage Pump

SUBMERSIBLESEWAGE PUMP

66119SEt UP And OPERAtInG InStRUctIOnS

distributed exclusively by Harbor Freight tools®.3491 Mission Oaks Blvd., Camarillo, CA 93011

Visit our website at: http://www.harborfreight.com

Read this material before using this product. Failure to do so can result in serious injury. SAVE tHIS MAnUAL.

Copyright© 2008 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.

For technical questions or replacement parts, please call 1-800-444-3353.

Page 2: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 2

SAVE tHIS MAnUALKeep this manual for the safety warn-

ings and precautions, assembly, operating, inspection, maintenance and cleaning pro-cedures. Write the product’s serial number in the back of the manual (or month and year of purchase if product has no num-ber). Keep this manual and the receipt in a safe and dry place for future reference.

IMPORtAnt SAFEtY InFORMAtIOn

In this manual, on the labeling, and all other information provid-ed with this product:

this is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

dAnGER indicates a hazardous

situation which, if not avoided, will result in death or serious injury.

WARnInG indicates a

hazardous situation which, if not avoided, could result in death or serious injury.

cAUtIOn, used with the safety

alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

nOtIcE is used to address practices

not related to personal injury.

cAUtIOn, without the safety alert

symbol, is used to address practices not related to personal injury.

General Safety Warnings WARnInG Read all safety warnings and instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The term ″power tool″ in the warnings refers to your line-operated (corded) power tool.

Work area safety1. Keep work area clean and well lit. a. Cluttered or dark areas invite acci-dents.Do not operate power tools in ex-b. plosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.Keep children and bystanders away c. while operating a power tool. Distrac-tions can cause you to lose control.

Electrical safety2. Power tool plugs must match the a. outlet. Never modify the plug in any way. Do not use any adapter plugs with grounded power tools. Unmodi-fied plugs and matching outlets will reduce risk of electric shock.Avoid body contact with grounded b. surfaces such as pipes, radiators,

Page 3: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 3

ranges and refrigerators. There is an increased risk of electric shock if your body is grounded.It is strongly recommended that this c. Pump be plugged into a Ground Fault Circuit Interrupter (GFCI). Ask a local electrician for easy installation instructions.To avoid electrical shock, no per-d. son or animal should be in contact with the waste water being pumped. Never walk on wet or damp area when the Pump is running in the same room.Do not pump hazardous materials. e. Do not pump explosive or flammable materials such as fuel oil, kerosene, gasoline, etc. Do not pump in close proximity to flammable or explosive materials. Do not pump fats, oils, or salt water. Do not pump hot liquid over 130° Fahrenheit. This Pump is designed to move waste water only. Do not abuse the cord. Never use f. the cord for carrying, pulling or un-plugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.When operating a power tool out-g. doors, use an extension cord suitable for outdoor use. Use of a cord suit-able for outdoor use reduces the risk of electric shock.

Personal safety3. Stay alert, watch what you are doing a. and use common sense when operat-ing a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or medica-

tion. A moment of inattention while operating power tools may result in serious personal injury.Use personal protective equipment. b. Always wear ANSI-approved safety eye goggles. Safety equipment such as non-skid safety shoes, NIOSH-approved dust mask/respirator, and heavy work gloves used for appropri-ate conditions will reduce personal injuries.Remove any adjusting key or wrench c. before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury.Do not overreach. Keep proper foot-d. ing and balance at all times. This enables better control of the power tool in unexpected situations.Dress properly. Do not wear loose e. clothing or jewelry. Keep your hair, clothing and gloves away from mov-ing parts. Loose clothes, jewelry or long hair can be caught in moving parts.Only use safety equipment that has f. been approved by an appropriate standards agency. Unapproved safety equipment may not provide adequate protection. Eye protection must be ANSI-approved and breath-ing protection must be NIOSH-ap-proved for the specific hazards in the work area.

Power tool use and care4. Do not force the power tool. Use the a. correct power tool for your applica-tion. The correct power tool will do the job better and safer at the rate for which it was designed.

Page 4: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 4

Do not use the Power Cord (1) or b. Float Switch (20) if they do not turn the tool on and off. Any power tool that cannot be controlled with the Power Cord is dangerous and must be repaired.Disconnect the Power Cord from the c. power source before making any ad-justments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.Store idle power tools out of the d. reach of children and do not allow persons unfamiliar with the power tool or these instructions to oper-ate the power tool. Power tools are dangerous in the hands of untrained users.Maintain power tools. Check for mis-e. alignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools.Use the power tool in accordance f. with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.

Service5. Have your power tool serviced by a. a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.

Pump Safety WarningsThis Pump has not been investigated 1. for use in swimming pool or marine areas.

Do not use extension cords with this 2. Pump.

This Pump is acceptable for indoor 3. and outdoor use.

If you choose to assemble and use 4. the Pump in a continuous run mode (without the Float Switch (20) at-tached) the Pump will turn on im-mediately when its Power Cord (1) is plugged into a 115 volt, grounded, electrical outlet. To turn off the Pump, unplug its Power Cord from its electri-cal outlet. do not allow the Pump to run dry.

If you choose to assemble and use 5. the Pump in an automatic on/off mode (with the Float Switch (20) at-tached), the Pump will turn on only when the level of waste water reach-es the height-adjustable Float Switch. When the level of waste water falls below the Float Switch, the Pump will automatically shut off.

Maintain labels and nameplates on 6. the Pump. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement.

Avoid unintentional starting. Prepare 7. to begin work before turning on the Pump.

Do not leave the Pump unattended 8. when it is plugged into an electrical outlet. Turn off the tool, and unplug it from its electrical outlet before leav-ing.

Page 5: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 5

This product is not a toy. Keep it out 9. of reach of children.

People with pacemakers should 10. consult their physician(s) before use. Electromagnetic fields in close prox-imity to heart pacemaker could cause pacemaker interference or pacemak-er failure. In addition, people with pacemakers should: • Avoid operating alone. • Do not use with power switch locked on. • Properly maintain and inspect to avoid electrical shock. • The Power Cord (1) must be prop-erly grounded. Ground Fault Circuit Interrupter (GFCI) should also be implemented it prevents sustained electrical shock.

Performance of this Pump may vary 11. depending on variations in local line voltage. Extension cord usage may also affect Pump performance.

WARNING: Handling the Power Cord 12. (1) on this product will expose you to lead, a chemical known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. (California Health & Safety Code § 25249.5, et seq.)

The warnings, precautions, and in-13. structions discussed in this instruction manual cannot cover all possible con-ditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.

SAVE tHESE InStRUctIOnS.

GROUndInG tO PREVEnt

ELEctRIc SHOck And dEAtH FROM IncORREct GROUndInG WIRE cOnnEctIOn: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. do not modify the Power cord Plug (1) or Float Switch Plug (20) provided with the Pump. never remove the grounding prong from the Plugs. do not use the Pump if the Power cords or Plugs are damaged. If damaged, have them repaired by a service facility before use. If the Power cord Plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded tools: tools with three Prong Plugs

Tools marked with “Grounding Re-1. quired” have a three wire cord and three prong grounding Plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a low

Page 6: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 6

resistance path to carry electricity away from the user, reducing the risk of electric shock. (See 3-Prong Plug and Outlet.)

The grounding prong in the Plug is 2. connected through the green wire in-side the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal. (See 3-Prong Plug and Outlet.)

The tool must be plugged into an 3. appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The Plug and outlet should look like those in the preceding illustration. (See 3-Prong Plug and Outlet.)

SYMBOLOGY

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~ Volts Alternating Current

A Amperes

n0 xxxx/min. No Load Revolutions per Minute (RPM)

SPEcIFIcAtIOnSPump Applications

Removes Waste Contaminants up to 1-1/2” Diameter

ElectricalInput

115 V~ / 60 Hz / 2/5 HP 11 Amps / 3400 RPMPower Plug: 3-Prong, GroundedPower Cord: 16AWG X 3C - SJOWFloat Switch Cord: 16AWG x 2C SJOW

Maximum Pumping Capacity

77 Gallons Per Minute

Pump Lift Capacity 32 Feet

Inlet & Outlet Size 1-5/8” x 2” - 11.5 NPT

Self Priming Yes

Automatic Overload Protection

Yes

Accessories 2” Diameter, 90° Elbow (Qty. 1)

UnPAckInGWhen unpacking, check to make sure

that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible.

PUMP InStALLAtIOn And OPERAtIOn

Read the EntIRE IMPORtAnt SAFEtY InFORMAtIOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Page 7: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 7

tO PREVEnt SERIOUS InjURY

FROM AccIdEntAL OPERAtIOn: Unplug the Pump from its electrical outlet before assembling or making any adjustments to the tool.

note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual.

Set the Pump on a level, solid foun-1. dation in the lowest area of the tank, sump, or receptacle where liquid level is no less than 3” above the suction inlet of the Pump. Never operate the Pump on earth, clay, sand, or gravel surfaces. (See Figure A, next page.)

Avoid installation in areas of extreme 2. heat or cold.

IMPORTANT: Never suspend the 3. Pump from its Power Cord (1) or dis-charge hose. You may firmly attach a rope to the Carrying Handle of the Pump. (See Figure A.)

Connect a 2” diameter hose (not in-4. cluded) firmly onto the 90° Elbow (32) of the Pump. (See Figure A.)

Route the hose to the desired dis-5. charge area. The hose should be kept as short as possible with a minimum number of turns. Additional plastic 90° elbows should be used if necessary to prevent hose kinking.

nOtE: The maximum delivery height of the Pump is 32 feet.

If the hose you install runs in excess 6. of ten feet, it is recommended you

use a check valve (not included) to prevent back flow, which could lead to rapid cycling. To avoid air locks in the Pump, drill a 3/16” diameter hole in the hose, between the check valve and the Pump. (See Figure A.)

If you choose to assemble and use 7. the Pump in a continuous run mode (without the Float Switch (20) at-tached) the Pump will turn on im-mediately when its Power Cord (1) is plugged into a 115 volt, grounded, electrical outlet. To turn off the Pump, unplug its Power Cord from its electri-cal outlet. do not allow the Pump to run dry. (See Figure A.)

If you choose to assemble and use 8. the Pump in an automatic on/off mode (with the Float Switch (20) attached), the Pump will turn on only when the level of waste water reaches the height - adjustable Float Switch. When the level of waste wa-ter drops below the Float Switch, the Pump will automatically shut off. (See Figure A.)

Plug the Power Cord (1) of the Pump 9. into the nearest 115 volt outlet fitted with a Ground Fault Circuit Interrupter (GFCI) to turn on the unit. (See Figure A.)

If running the Pump in the 10. continuous mode, Unplug the Power Cord (1) from its GFCI electrical outlet to turn off the Pump. (See Figure A.)

If running the Pump with the Float 11. Switch (20) connected, the Float Switch will automatically turn off the Pump when the level of waste water drops below the Switch. (See Figure A.)

Page 8: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 8

FIGURE AtO cOnnEct tHE

FLOAt SWItcH115 VOLtGFcI

OUtLEt

2” dIAMEtERdIScHARGE

HOSE

FLOAtSWItcH

(20)cHEckVALVE

ORUnIOn

HAndLE

3/16”AIR

BLEEdHOLE

MAIntEnAncE And SERVIcInG

Procedures not specifically explained in this manual must be performed only by a qualified technician.

tO PREVEnt SERIOUS InjURY

FROM AccIdEntAL OPERAtIOn: Unplug the Pump from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.

tO PREVEnt SERIOUS InjURY FROM tOOL FAILURE: do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.

BEFORE EACH USE, inspect the 1. general condition of the Pump. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, damaged discharge hose, and any other condition that may affect its safe operation.

BEFORE EACH USE, Check to make 2. sure the Base (35) is free of dirt, rocks, and debris. (See Assy. diagram.)

AFTER USE,3. clean external surfaces of the Pump with clean cloth. Then store the Pump in a clean, dry, safe location out of reach of children and other unauthorized persons.

4. WARNING! If the Power Cord (1) of this Pump is damaged, it must be replaced only by a qualified service technician.

Page 9: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 9

PLEASE REAd tHE FOLLOWInG cAREFULLYTHE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

tROUBLESHOOtInGProblem Possible causes Possible Solutions

Pump runs, but will not deliver any waste water.

Base clogged.1.

The necessary waste water 2. height (3”) falls below the minimum water level.Low line voltage.3. Optional check valve stuck or 4. installed backwards.Impeller clogged.5.

Clean out dirt, rocks, and debris from Base.1.

There must be at least 3” deep waste water 2. for the Pump to operate properly.

Consult with an electrician.3. Remove and examine check valve.4.

Have a qualified service technician dismantle 5. the unit and clean out the Impeller.

Pump won’t start or run.

Check power connections and 1. circuits/fuses.Water level too low (if using 2. the Float Switch.Impeller clogged.3.

Defective motor.4.

Consult with an elecrician.1.

Move the Float Switch to a lower location.2.

Have a qualified service technician dismantle 3. and clean out the Impeller.Have a qualified service technician repair or 4. replace.

Excessive noise or vibration.

Worn bearings.1.

Debris in Impeller.2.

Discharge hose restricted.3.

Have a qualified service technician repair or 1. replace.Have a qualified service technician dismantle 2. and clean out the Impeller.Clean Pump and discharge hose.3.

Pump starts and stops too frequently.

Water temperature too high.1.

Back flow of water from 2. discharge hose.

Do not exceed temperatures above 130° 1. Fahrenheit.Install or inspect optional check valve.2.

Follow all safety precautions whenever diagnosing or servicing the tool. disconnect power supply before service.

Page 10: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 10

PARtS LISt & ASSEMBLY dIAGRAM

Page 11: Sewage Pump

SKU 66119 For technical questions, please call 1-800-444-3353. Page 11

Record Product’s Serial number Here: note: If product has no serial number, record month and year of purchase instead.

note: Some parts are listed and shown for illustration purposes only, and are not avail-able individually as replacement parts.

LIMItEd 1 YEAR / 90 dAY WARRAntYHarbor Freight Tools Co. makes every effort to assure that its products meet high

quality and durability standards, and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine/motor, the belts (if so equipped), and the blades (if so equipped) are free of defects in materials and workmanship. Har-bor Freight Tools also warrants to the original purchaser, for a period of one year from date of purchase, that all other parts and components of the product are free from defects in materials and workmanship (90 days if used by a professional contractor or if used as rental equipment). This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or con-sequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.

To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the com-plaint must accompany the merchandise. If our inspection verifies the defect, we will ei-ther repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return re-paired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353


Recommended