Date post: | 10-Oct-2014 |
Category: |
Documents |
Upload: | manoj-kage |
View: | 219 times |
Download: | 4 times |
High Efficiency Steam Turbine Generators
Shin NipponMachinery Co.
Introducing
• Established in 1951
• Wholly owned subsidiary of Sumitomo Heavy Industries
• Annual Sales $ 340 million
• 400 Employees
• Capacity to mfg 70 multistage + 100 single stage steam turbines / yr
• KURE WORKS
(HIROSHIMA-KURE)
TOKYO
HEAD OFFICE
KURE CITY
• All Steam Turbines madeat SNM factory in Japan.No mfg outsourcing tothird world.
• Factory at Kure City nearHiroshima has direct access to port.
• Equipment loaded forinternational export withno trucking within Japan.
History of Reliable, On -Time Deliveries
USA
MexicoDominicanRepublic
Trinidad & Tobago
Cuba
Venezuela
Ecuador
PeruBrazil
Chile
Argentina
Algeria Egypt
Nigeria Sudan
South Africa
Poland
Spain
Slovakia
Bulgaria
Romania
Saudi
KuwaitIraq
Iran
Qatar
UAEUAEUAEUAE
Bahrain
Russia
Turkmenistan
UzbekistanChina
BangladeshPakistan
India
North KoreaKorea Japan
Thailand
Myanmar
MalaysiaVietnam
Singapore
Brunei
Indonesia
MacaoHong Kong
Australia
New Caledonia Fiji
Turkey
Canada
NicaraguaBarbados
PanamaCosta Rica
Honduras
Colombia
Bolivia
Uruguay
Guiana
LiberiaGhana
Niger
Tanzania
Malawi
MoroccoTunisia
Germany
Austria
Oman
Cambodia
Sri Lanka
Papua New Guinea
Philippine
Taiwan
Uganda
Belarus
Total Countries ::::81Total Units: 6,592
Shin Nippon Steam Turbine Deliveries 1970 – 2010
35 Steam Turbine GeneratorsIn all regions of USA and Canada
№ MODELDRIVEN
MACHINEQ'TY
OUTPUT
(kW)
SPEED
(RPM)END USER COUNTRY YEAR
1 B6-R4-R Generator 1 4000 6686 DAVIS HAMAKUA SUGAR COMPANY USA 198012
2 C10-R9 Generator 1 7500 3600 THEO DAVIES HAMAKUA SUGAR USA 198312
3 C8-R13-ER Generator 1 7165 5021 CHAPLEAU CO-GENERATION Canada 198606
4 B4-R4-R SHRED 1 1866 9055 HAMAKUA SUGAR COMPANY USA 198601
5 C6-R13-ER Generator 1 8030 5795 CHINO CO-GENERATION PROJECT USA 198707
6 C6-R13-ER Generator 1 7950 5795 CAMARILLO STATE HOSPITAL USA 198707
7 C8-R13-AR Generator 1 10500 5005 CARSON CO-GENERATION PLANT USA 198901
8 C8-R14-ER Generator 1 11600 5005 O'BRIEN CALIFORNIA COGENERATION LTD USA 198902
9 C9-R13-R Generator 1 12500 4041 MALETTE KRAFT PULP AND POWER LTD Canada 198905
10 B6-R4-R SHREDE 1 3728 7492 COMMERCIAL & SUGAR CO.,LTD HAWAIIAN USA 198812
11 B6-R7-R Generator 1 9800 5723 EXXON COMPANY U.S.A. SYU PROJECT USA 199103
12 C8-CR15-ER Generator 1 10600 5023 LOS ANGELES COUNTY SANITATION DISTRICT USA 198910
13 C8-R12-ER Generator 1 8000 5021 WATSONVILE CO-GENERATION PROJECT USA 198912
14 C8-R9-ER Generator 1 15400 4985 HAWKER SIDDLEY POWER ENGINEERING INC USA 199004
15 C10-R13-E Generator 1 22000 3600 SOUTH GLENS FALLS COGENE USA 199011
16 C10-R13-E Generator 1 22000 3600 CARTHAGE COGENERATION USA 199011
17 C6-R13-ER Generator 1 7535 5800 AGNEWS STATE HOSPITAL USA 199007
18 C9-R12-ER Generator 1 14500 4200 UCLA COGENERATION CHILLER PLANT USA 199210
North American Installations – Sheet 1 of 2
North American Installations – Sheet 2 of 2
№ MODELDRIVEN
MACHINEQ'TY
OUTPUT
(kW)
SPEED
(RPM)END USER COUNTRY YEAR
19 C8-R12-ER Generator 1 10500 5000 ICE FLOE COGENERATION PROJECT USA 199407
20 C9-R15-ER Generator 1 25600 4900 CANADIAN GAS & ELECTRIC INC Canada 200209
21 C8-R12-R Generator 1 8475 6194 CITY OF CORONA USA 200307
22 B8-R8-ER Generator 1 25000 4200 WHITE MOUNTAIN ENERGY, LLC USA 200311
23 C6-R9-ER Generator 1 8700 7800 COUNTY SANITATION DISTRICTS OF LOS ANGELES COUNTY USA 200510
24 B8-R4-ER Generator 1 14210 5000 BETHEL ENERGY LLC USA 200909
25 C10-R10-EX Generator 1 38690 3600 BETHEL ENERGY LLC USA 200909
26 C11-R16-EX Generator 1 67000 3600 SUN COKE COMPANY USA 200803
27 C9-R12-ER Generator 1 25000 4200 BULL MOOSE ENERGY LLC USA
28 C10-R15-EX Generator 1 39200 3600 WESTERN WATER AND POWER LIMITED, LLC USA
29 B6-R8-ER Generator 1 9300 5300 PRATT INDUSTRIES (USA) MILL DIVISION CONYERS USA 200808
30 B6-R3-R Generator 1 8500 6500 THOROLD COGEN, L.P Canada 200903
31 C11-R13-EX Generator 1 48000 3600 ZELLSTOFF CELGAR LIMITED PARTNERSHIP Canada 200909
32 C11-R16-EX Generator 1 67000 3600 SUN COKE COMPANY USA 200903
33 C11-R12-EX Generator 1 60000 3600 VISION POWER SYSTEMS, INC. USA 999912
34 C10-R14-ARX Generator 1 28000 4300 FORT NELSON GENERATING STATION Canada 201101
35 C11-R16-EX Generator 1 67000 3600 FITZGERALD RENEWABLE ENERGY, LLC. USA 201010
• Inlet Steam Conditions – Up To 130 Bar (1850 PSI)– Up To 550℃ (1022 F)
• Exhaust Steam Conditions– Condensing or Back Pressure
• Output & Speed– 1Kw To 80,000 Kw– Direct Drive or Geared
Product Design & Capabilities
Impulse BladingReduces Performance Loss Over Time
Direction of Exhaust Outlet OUTPUT (MW)Axial Down Up Side
B4B5B6B8
B10C4C5C6C7C8C9
C10C11
○○○○ ○○○○ ○○○○
20 40 60 80 100
○○○○ ○○○○ ○○○○
○○○○ ○○○○ ○○○○
○○○○ ○○○○
○○○○ ○○○○
○○○○ ○○○○
○○○○ ○○○○
○○○○ ○○○○ ○○○○
○○○○ ○○○○ ○○○○
○○○○ ○○○○ ○○○○
○○○○ ○○○○ ○○○○
○○○○ ○○○○
○○○○ ○○○○
Model
Steam Turbine Models & Exhaust Configurations
B = BackpressureC = Condensing
Axial Exhaust vs. Down Exhaust
Down ExhaustSteam Turbine on Mezzanine
Axial ExhaustSteam Turbine & Condenser
at same level
Condenser
Sun Coke CorporationHaverhill, Ohio
• Model C11-R16-EX
• 67,000 kW Brush Generator
• 3600 RPM – Direct Drive
• Inlet 1555 psia x 1000 F
• Woodward Sliding Pressure Controls
• Exhaust 1.35 psia ( 2.7” Hga)
• 2 Bleed Extractions
Typical Axial ExhaustInstallation
The Axial Exhaust AdvantageSteam Turbine & Condenser
at same level
Shin Nippon Models Available with Axial Exhaust
No Additional Price or Delivery
Efficiency Improvement - Reduces Steam Turbine Exhaust Loss
Cost Reduction – Reduces building height and size of foundations
Quicker Installation – Far less site labor required
Shin Nippon Factory Testing• Every turbine tested
at no -load, 100% rpm
• Contract Controls Utilized for shop test
• Live Steam Checkson Casing and Sealing
Reduces Surprises at Jobsite
Shin Nippon = Your Best Choice1 to 80 MW Steam Turbine Gensets
• 60 Years of Experience• High Efficiency Design• Axial Exhaust Configuration• Direct Drive for most applications• History of On -Time Shipment
Competitive Price & Delivery