SHINE ON CAR WASH, LP
2811 E. MAIN ST.
ALICE, TX 78332
CONTACT: SHANE WEISS
PHONE: 361-537-2257
EMAIL: [email protected]
CIVIL ENGINEER:
BUILDING PROPERTIES
BUILDING CODES
CODE SUMMARY
ARCHITECT:
OWNER:
PROJECT TEAM
GENERAL ARCHITECTURAL LEGEND
GENERAL NOTES
LOCATION MAP
N.T.S.
BASS & WELSH ENGINEERING
3054 S. ALAMEDA ST.
CORPUS CHRISTI, TX 78404
CONTACT: MURRAY BASS
PHONE: 361-882-5521EMAIL: [email protected]
A PLUS DESIGN GROUP
2653 SAGEBRUSH DR. SUITE 200
FLOWER MOUND, TEXAS 75028
CONTACT: ANDREW MELETTA
PHONE: 972-724-4440
EMAIL: [email protected]
NORTHWEST BOULEVARD
CORPUS CHRISTI, TX 78410
SHINE ON
CAR WASH
G1.1 GENERAL INFORMATION
CIVIL UNDER SEPARATE PERMIT
S001 GENERAL NOTES
S111 FOUNDATION PLANS
S121 ROOF FRAMING PLANS
S301 FOUNDATION DETAILS
S302 FOUNDATION DETAILS
S303 FOUNDATION DETAILS
S401 MASONRY DETAILS
S402 MASONRY DETAILS
S501 FRAMING DETAILS
S502 FRAMING DETAILS
A1.1 SITE PLAN AND DETAILS
A2.1 FLOOR PLANS
A2.2 SCHEDULES AND DETAILS
A2.3 MILLWORK SECTIONS AND DETAILS
A3.1 EXTERIOR ELEVATIONS, WINDOW
ELEVATIONS, AND SCHEDULES
A4.1 REFLECTED CEILING PLAN, ROOF PLAN,
SCHEDULES, AND DETAILS
A5.1 WALL SECTIONS AND DETAILS
A5.2 WALL SECTIONS AND DETAILS
A5.3 WALL SECTIONS AND DETAILS
A6.1 TRENCH PLAN AND DETAILS
M1.1 MECHANICAL FLOOR PLAN AND NOTES
M2.1 MECHANICAL SCHEDULES AND DETAILS
E1.1 LIGHTING FLOOR PLAN AND SCHEDULES
E1.2 POWER FLOOR PLAN
E2.1 ELECTRICAL SCHEDULES AND RISER
E3.1 MCC DIAGRAM
P1.1 PLUMBING UNDER AND ABOVE FLOOR
PLANS
P1.2 PLUMBING ROOF PLAN
P2.1 PLUMBING SCHEDULES AND DETAILS
P2.2 PLUMBING SCHEDULES AND DETAILS
SHEET INDEX
STRUCTURAL ENGINEER:
MONGHATE ENGINEERING, INC.
3010 LBJ FREEWAY
DALLAS, TX 75234
CONTACT: PEDRO GARCIA
PHONE: 214-736-9787
EMAIL: [email protected]
MEP ENGINEER:
LIPPE AND ASSOCIATES
CONSULTING ENGINEERS
15950 MIDWAY RD.
ADDISON, TX 75001
CONTACT: JEFF HANCOCK
PHONE: 972-387-3500
EMAIL: [email protected]
PROJECT
LOCATION
INTERIOR WALLS
PERIMETER WALLS
FOUNDATION
ROOF
MAIN FLOOR
EXIT THROUGH INTERVENING ROOM
MINUMUM NUMBER OF EXITS
OCCUPANCY SEPARATIONS
EGRESS WIDTH PER OCCUPANT-STAIRS
EGRESS WIDTH PER OCCUPANT-CORRIDORS
MINIMUM CORRIDOR WIDTH & HEIGHT
MEANS OF EGRESS
ACCESSIBLE FACILITIES
MEN'S AND WOMEN'S LAVATORIES
MEN'S AND WOMEN'S WATER CLOSETS
PLUMBING REQUIREMENTS
DETAILED OCCUPANCY REQUIREMENTS - CAR WASH BUILDING
FIRE RESISTANCE OF SHAFTS
FIRE RATING OF CORRIDORS
FIRE PROTECTION OF ROOF CONSTRUCTION
FIRE PROTECTION OF FLOOR CONSTRUCTION
FIRE PROTECTION OF INTERIOR WALLS
FIRE PROTECTION OF EXTERIOR WALLS
FIRE RESISTANCE OF STRUCTURAL MEMBERS
DETAILED CONSTRUCTION REQUIREMENTS
HEIGHT AND AREA INCREASES
MAXIMUM FLOOR AREA
MAXIMUM HEIGHT
TYPE
MINIMUM TYPE OF CONSTRUCTION
PERCENT OF EXTERIOR OPENINGS/FLOOR
SEPARATION DISTANCE FROM PROPERTY LINES
CAR WASH BLDG
CAR WASH BLDG
DRINKING FOUNTAINS
OFFICE - 434 SF (BUSINESS OCCUPANCY)
OCCUPANCY CLASSIFICATION
EQUIPMENT - 900 SF (MECHANICAL OCCUPANCY)
TUNNEL - 2,356 SF (ACCESSORY/MECHANICAL OCC.)
OCCUPANCY TOTALS
No. DATE
REVISIONS
Drawn by:
Checked by:
Project No.
Date
NOTE
SU
P S
UB
MIT
TA
L S
ET
NO
T F
OR
C
ON
ST
RU
CT
IO
N
972-724-4440972-691-7731 FAX
CONSTRUCTIONINTERIORS
ARCHITECTURE
APDG.US
A PLUS DESIGNGROUP
95
% R
EV
IE
W S
ET
NO
T F
OR
C
ON
ST
RU
CT
IO
N
A N
EW
C
AR
W
AS
H
FA
CILIT
Y F
OR
:
CO
RP
US
C
HR
IS
TI, T
EX
AS
C COPYRIGHT A PLUS DESIGN GROUP 2017
PRELIMINARY
NOT FOR
CONSTRUCTION
Trent W. Clark, Architect
TX Registration # 17084
These Drawings are
incomplete and may not be
used for regulatory approval,
permit, or construction.
These drawings are for
informational purposes
only.
The information herein
is by the equipment
manufacture.
SH
IN
E O
N C
AR
W
AS
H
G1.1
COVER PAGE
AutoCAD SHX TextELEVATION
AutoCAD SHX TextWALL SECTION
AutoCAD SHX TextDETAIL SECTION
AutoCAD SHX TextINTERIOR ELEVATION
AutoCAD SHX TextELEVATION TAG
AutoCAD SHX TextEXTERIOR ELEVATION
AutoCAD SHX TextMILLWORK TAG (SEE SCHEDULE)
AutoCAD SHX TextFIXTURE TAG
AutoCAD SHX TextX
AutoCAD SHX TextX
AutoCAD SHX TextCOLUMN BUBBLE
AutoCAD SHX TextX
AutoCAD SHX TextROOM TAG
AutoCAD SHX TextDOOR TAG (SEE SCHEDULE)
AutoCAD SHX TextWALL TAG (SEE SCHEDULE)
AutoCAD SHX TextWINDOW TAG (SEE ELEVATIONS)
AutoCAD SHX TextX'-X"
AutoCAD SHX TextX
AutoCAD SHX TextPLUS ADDED CITY ORDINANCES & AMENDMENTS
AutoCAD SHX Text2015 INTERNATIONAL ENERGY CONVERSATION CODE
AutoCAD SHX TextTEXAS ACCESSIBILITY STANDARDS
AutoCAD SHX Text2014 NATIONAL ELECTRICAL CODE
AutoCAD SHX Text2015 INTERNATIONAL FUEL GAS CODE
AutoCAD SHX Text2015 INTERNATIONAL FIRE CODE
AutoCAD SHX Text2015 INTERNATIONAL PLUMBING CODE
AutoCAD SHX Text2015 INTERNATIONAL MECHANICAL CODE
AutoCAD SHX Text2015 INTERNATIONAL BUILDING CODE
AutoCAD SHX TextX
AutoCAD SHX TextAx.x
AutoCAD SHX TextREVISION TAG
AutoCAD SHX TextDRAWING NUMBER
AutoCAD SHX TextSHEET NUMBER
AutoCAD SHX TextDRAWING NUMBER
AutoCAD SHX TextSHEET NUMBER
AutoCAD SHX TextELEVATION
AutoCAD SHX TextDESCRIPTION
AutoCAD SHX TextDRAWING NUMBER
AutoCAD SHX TextSHEET NUMBER
AutoCAD SHX TextX/xxx
AutoCAD SHX TextX
AutoCAD SHX TextAx.x
AutoCAD SHX Text1
AutoCAD SHX Text2
AutoCAD SHX Text3
AutoCAD SHX Text4
AutoCAD SHX TextX
AutoCAD SHX Texta
AutoCAD SHX TextX
AutoCAD SHX TextAx.x
AutoCAD SHX TextX
AutoCAD SHX TextX
AutoCAD SHX TextNAME
AutoCAD SHX TextNUMBER
AutoCAD SHX TextM-XX
AutoCAD SHX Text1.CONTRACTOR/BIDDER TO VISIT SITE AND FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. CONTRACTOR/BIDDER TO VISIT SITE AND FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. 2.CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, TOOLS, AND INCIDENTAL PARTS AND MATERIALS EVEN IF CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, TOOLS, AND INCIDENTAL PARTS AND MATERIALS EVEN IF NOT SPECIFICALLY NOTED ON THE PLANS, FOR A COMPLETE OPERATIVE INSTALLATION. 3.THOSE ITEMS NOTED N.I.C. (NOT IN CONTRACT), OR NOTED TO BE PERFORMED BY OTHERS, SHALL BE THOSE ITEMS NOTED N.I.C. (NOT IN CONTRACT), OR NOTED TO BE PERFORMED BY OTHERS, SHALL BE COORDINATED IN A MUTUALLY, AGREEABLE AND COOPERATIVE MANNER BY THE CONTRACTOR SO AS TO ALLOW TIMELY INTEGRATION INTO THE PROJECT AS REQUIRED. 4.UNLESS NOTED OTHERWISE, MOVING OF FURNITURE, FURNISHINGS, AND EQUIPMENT SHALL BE PERFORMED BY UNLESS NOTED OTHERWISE, MOVING OF FURNITURE, FURNISHINGS, AND EQUIPMENT SHALL BE PERFORMED BY OWNER/TENANT. COORDINATE TIMING WITH REPRESENTATIVE. 5.PERFORMED DURING PROJECT, MAINTAIN A JOBSITE SET OF CONSTRUCTION DOCUMENTS. ON THESE, RECORD ANY PERFORMED DURING PROJECT, MAINTAIN A JOBSITE SET OF CONSTRUCTION DOCUMENTS. ON THESE, RECORD ANY DEVIATIONS FROM THE ORIGINAL PLANS, LOCATE CONCEALED PLUMBING PIPING, AND SYSTEM TIE-INS TURN. TURN SET OVER TO OWNER/TENANT UPON COMPLETION OF PROJECT. 6.CONTRACTOR(S) SHALL CONFINE THEIR CONSTRUCTION ACTIVITIES AND PARKING TO DESIGNATED AREAS ONLY. CONTRACTOR(S) SHALL CONFINE THEIR CONSTRUCTION ACTIVITIES AND PARKING TO DESIGNATED AREAS ONLY. STAGING AND STORAGE IN CONSTRUCTION AREA(S) OR, IF ADDITIONAL SPACE IS REQUIRED, IN OWNER/TENANT DESIGNATED AREA OR ROOM. SUPPLY AND REMOVAL OF MATERIALS BY PRIOR APPROVED ROUTES ONLY. 7.ALL DEMOLISHED MATERIALS SHALL BE DISPOSED OF BY CONTRACTOR, UNLESS NOTED OTHERWISE. ALL DEMOLISHED MATERIALS SHALL BE DISPOSED OF BY CONTRACTOR, UNLESS NOTED OTHERWISE. 8.CLEAN CONSTRUCTION AREA THOROUGHLY UPON COMPLETION. DO NOT USE BUILDING DUMPSTERS. DISPOSE OF CLEAN CONSTRUCTION AREA THOROUGHLY UPON COMPLETION. DO NOT USE BUILDING DUMPSTERS. DISPOSE OF DEBRIS IN ACCORDANCE WITH LOCALLY APPROVED REGULATIONS. 9.ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH LOCALLY APPLICABLE CODES AND REGULATIONS, ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH LOCALLY APPLICABLE CODES AND REGULATIONS, INCLUDING THE MUNICIPAL BUILDING CODE, N.E.C., A.D.A., AND STATE PROGRAMS FOR THE ELIMINATION OF ARCHITECTURAL BARRIERS, CURRENT AS OF DATE OF ISSUANCE OF THESE DOCUMENTS. 10.ALL DIMENSIONS SHOWN ARE TO FINISH SURFACE AND/OR CENTERLINE OF STRUCTURE OR WALL FRAMING. ALL DIMENSIONS SHOWN ARE TO FINISH SURFACE AND/OR CENTERLINE OF STRUCTURE OR WALL FRAMING. 11.CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITION, AND DIMENSIONS CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITION, AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. OBTAIN CLARIFICATION FROM ARCHITECT OR ANY QUESTIONS. 12.SUBMIT SHOP DRAWINGS/PRODUCT INFORMATION/SAMPLES OF SPECIFIED PRODUCTS. FABRICATIONS SHALL BEGIN SUBMIT SHOP DRAWINGS/PRODUCT INFORMATION/SAMPLES OF SPECIFIED PRODUCTS. FABRICATIONS SHALL BEGIN ONLY AFTER APPROVED SHOP DRAWINGS HAVE BEEN RETURNED BY GENERAL CONTRACTOR. 13.CONTRACTOR SHALL SUBMIT CONFIRMATION OF DELIVERY DATES OF PRODUCTS WITH LONG LEAD TIMES WITH CONTRACTOR SHALL SUBMIT CONFIRMATION OF DELIVERY DATES OF PRODUCTS WITH LONG LEAD TIMES WITH PRODUCT SUBMITTALS. 14.INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURERS INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS. 15."TYPICAL" OR "TYP." MEANS THE CRITERIA IS TO BE USED FOR ALL OTHER SIMILAR CONDITIONS UNLESS NOTED "TYPICAL" OR "TYP." MEANS THE CRITERIA IS TO BE USED FOR ALL OTHER SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. 16.ALL PERMITS, LICENSES, AND INSPECTIONS REQUIRED TO PERFORM AND COMPLETE WORK SHALL BE SECURED BY ALL PERMITS, LICENSES, AND INSPECTIONS REQUIRED TO PERFORM AND COMPLETE WORK SHALL BE SECURED BY AND PAID FOR BY CONTRACTOR. 17.ALL MATERIALS SHALL BE NEW AND OF FIRST QUALITY. ALL WORKMANSHIP SHALL BE PERFORMED BY SKILLED ALL MATERIALS SHALL BE NEW AND OF FIRST QUALITY. ALL WORKMANSHIP SHALL BE PERFORMED BY SKILLED CRAFTSMEN. ALL MATERIALS AND LABOR SHALL MEET THE HIGHEST STANDARDS OF THE INDUSTRY. 18.EACH CONTRACTOR SHALL REPLACE AND/OR RESTORE ALL MATERIALS STORED OR INSTALLED ON THE SITE EACH CONTRACTOR SHALL REPLACE AND/OR RESTORE ALL MATERIALS STORED OR INSTALLED ON THE SITE SUBJECT TO DAMAGE OR THEFT. 19.EACH CONTRACTOR SHALL CONSULT WITH THE RESPECTIVE MUNICIPAL FIRE DEPARTMENT AUTHORITIES HAVING EACH CONTRACTOR SHALL CONSULT WITH THE RESPECTIVE MUNICIPAL FIRE DEPARTMENT AUTHORITIES HAVING JURISDICTION RELATIVE TO REQUIREMENTS FOR FIRE EXTINGUISHER PROTECTION IN THE BUILDING WHILE UNDER CONSTRUCTION. CONSTRUCTION FIRE EXTINGUISHERS SHALL BE PROVIDED BY THE CONTRACTOR. 20.CONTRACTOR SHALL NOT CUT, REMOVE, OR ALTER ANY BEARING WALL, WALL OPENING, FOOTING, ROOF CONTRACTOR SHALL NOT CUT, REMOVE, OR ALTER ANY BEARING WALL, WALL OPENING, FOOTING, ROOF STRUCTURE, OR DECKING UNTIL THE CONTRACTOR HAS PROVIDED THE PROPER SHORING, BRACING, AND SUPPORT REQUIRED TO MAINTAIN THE STRUCTURAL INTEGRITY OF THE PROJECT. 21.CONTRACTOR SHALL PERMANENTLY CAP ANY PLUMBING LINE TO ABANDONED AT THEIR POINT OF BUILDING CONTRACTOR SHALL PERMANENTLY CAP ANY PLUMBING LINE TO ABANDONED AT THEIR POINT OF BUILDING ENTRY. 22.CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING ALL SURFACES TO RECEIVE NEW FINISHES. SURFACES CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING ALL SURFACES TO RECEIVE NEW FINISHES. SURFACES SHALL BE PATCHED, FILLED, STRIPPED, AND/OR CLEANED AS REQUIRED TO PROVIDE A SMOOTH DURABLE SURFACE FREE OF ALL BURRS, ADHESIVES, AND DEBRIS SUITABLE FOR RECEIVING NEW FINISHES. 23.IT IS THE RESPONSIBILITY OF ALL CONTRACTORS TO USE THE COMPLETE SET OF PLANS AND SPECIFICATIONS TO IT IS THE RESPONSIBILITY OF ALL CONTRACTORS TO USE THE COMPLETE SET OF PLANS AND SPECIFICATIONS TO PERFORM THEIR WORK. 24.TWO COMPLETE SETS OF DETAILED SHOP DRAWINGS SHALL BE SUBMITTED TO GOVERNMENTAL AUTHORITIES & TWO COMPLETE SETS OF DETAILED SHOP DRAWINGS SHALL BE SUBMITTED TO GOVERNMENTAL AUTHORITIES & APPROVED PRIOR TO THE START OF MODIFICATION, FABRICATION, OR INSTALLATION FOR AUTOMATIC FIRE SUPPRESSION SYSTEM WHEN APPLICABLE. 25.A.D.A.A.G. & T.A.S. COMPLIANCE: A.D.A.A.G. & T.A.S. COMPLIANCE: THIS FACILITY FALLS UNDER THE PUBLIC ACCOMMODATIONS AND COMMERCIAL FACILITIES CATEGORIES AS DEFINED BY THE TEXAS ACCESSIBILITY STANDARDS (T.A.S.) OF THE ARCHITECTURAL BARRIERS ACT, ARTICLE ARTICLE 9102, TEXAS CIVIL STATUTES, EFFECTIVE APRIL 1, 1994. T.A.S. IS BASED ON THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (A.D.A.A.G.), AND ALL REQUIREMENTS NECESSARY FOR COMPLYING WITH A.D.A.A.G. ARE INCLUDED IN T.A.S. PLANS WILL BE SUBMITTED FOR T.D.L.R. REVIEW AND APPROVAL BY ARCHITECT; T.DL.R. WILL MAKE AN ON-SITE COMPLIANCE INSPECTION. OWNER WILL PAY ALL FEES IN RELATION TO T.A.S. 26.ALL WOOD TO BE PRESSURE TREATED AND FIRE RETARDANT TREATED. ALL WOOD TO BE PRESSURE TREATED AND FIRE RETARDANT TREATED. 27.LIGHTING DESIGN AND FIXTURE SELECTIONS ARE IN COMPLIANCE WITH THE COMCHECK. ANY ALTERNATE DESIGNS LIGHTING DESIGN AND FIXTURE SELECTIONS ARE IN COMPLIANCE WITH THE COMCHECK. ANY ALTERNATE DESIGNS OR FIXTURES SELECTIONS MUST BE EQUAL OR BETTER IN QUALITY, FUNCTION, AND COMPLIANCE WITH THE COMCHECK.
AutoCAD SHX Text0 HOURS PROVIDED
AutoCAD SHX Text0 HOURS PROVIDED
AutoCAD SHX Text0 HOURS PROVIDED
AutoCAD SHX Text0 HOURS PROVIDED
AutoCAD SHX Text0 HOURS PROVIDED
AutoCAD SHX TextNA
AutoCAD SHX TextPROVIDED
AutoCAD SHX TextREQUIRED
AutoCAD SHX TextPROVIDED
AutoCAD SHX TextREQUIRED
AutoCAD SHX TextMETAL STUDS WITH 5/8" DRYWALL
AutoCAD SHX TextSINGLE WYTHE REINFORCED CONCRETE BLOCK
AutoCAD SHX TextREINFORCED CONCRETE ON FOOTINGS
AutoCAD SHX TextSTEEL FRAME SYSTEM W/ SINGLE PLY ROOFING SYSTEM
AutoCAD SHX TextREINFORCED CONCRETE ON ENGINEERED FILL
AutoCAD SHX Text1/40 OCCUPANTS
AutoCAD SHX Text1 PER SPACE
AutoCAD SHX TextN/A
AutoCAD SHX TextTABLE 508.3.3
AutoCAD SHX Text1 HOUR
AutoCAD SHX TextTABLE 1018.1
AutoCAD SHX Text1018.2
AutoCAD SHX TextN/A
AutoCAD SHX TextW 36"
AutoCAD SHX TextW 36" H 7'-6"
AutoCAD SHX TextUNISEX TOILET IS ACCESSIBLE
AutoCAD SHX Text1 UNISEX PROVIDED
AutoCAD SHX TextTABLE 2902.1
AutoCAD SHX TextTABLE 2902.1
AutoCAD SHX TextTABLE 2902.1
AutoCAD SHX Text1 PER FLOOR
AutoCAD SHX Text1/25 OCCUPANTS
AutoCAD SHX TextTABLE 1004.1.2
AutoCAD SHX Text304
AutoCAD SHX Text0 HOURS PROVIDED
AutoCAD SHX Text707
AutoCAD SHX TextTABLE 1004.3.2.1
AutoCAD SHX TextTABLE 601
AutoCAD SHX TextTABLE 601
AutoCAD SHX TextTABLE 601
AutoCAD SHX TextTABLE 601, 602
AutoCAD SHX TextTABLE 601
AutoCAD SHX Text0 HOURS
AutoCAD SHX Text0 HOURS
AutoCAD SHX Text0 HOURS
AutoCAD SHX Text0 HOURS
AutoCAD SHX Text0 HOURS
AutoCAD SHX Text0 HOURS
AutoCAD SHX Text0 HOURS
AutoCAD SHX Text-
AutoCAD SHX Text-
AutoCAD SHX TextTABLE 503
AutoCAD SHX Text602.2/TABLE 601
AutoCAD SHX TextTABLE 705.8
AutoCAD SHX TextTABLE 602
AutoCAD SHX Text503
AutoCAD SHX Text-
AutoCAD SHX Text503
AutoCAD SHX TextNOT NECESSARY
AutoCAD SHX Text23,000 SQUARE FEET PER FLOOR
AutoCAD SHX Text55 FEET AND 3 STORIES
AutoCAD SHX TextTYPE II-B
AutoCAD SHX TextUNLIMITED PER 705.8.2
AutoCAD SHX Text10-30 FEET
AutoCAD SHX Text1 STORY, 29'-0" FEET AT EXIT TOWERS
AutoCAD SHX Text4110 G.S.F.
AutoCAD SHX Text1 PER SPACE
AutoCAD SHX TextREQUIRED
AutoCAD SHX TextPROVIDED
AutoCAD SHX TextBOTTLED WATER COOLERS ARE PROVIDED PER IPC 410.1
AutoCAD SHX TextTABLE 2902.1
AutoCAD SHX Text1/100 OCCUPANTS
AutoCAD SHX TextNO STAIRS IN PROJECT
AutoCAD SHX Text500 GROSS SF PER OCCUPANT = 900/300 = 3 OCCUPANTS
AutoCAD SHX Text100 GROSS SF PER OCCUPANT = 434/100= 5 OCCUPANTS
AutoCAD SHX TextBUSINESS GROUP B (302.3.1 NON-SEPERATED USE)
AutoCAD SHX Text500 GROSS SF PER OCCUPANT = 2,356/300= 8 OCCUPANTS
AutoCAD SHX Text16 OCCUPANTS
AutoCAD SHX TextBLDG. HEIGHT
AutoCAD SHX TextFLOOR AREA
AutoCAD SHX TextN/A
AutoCAD SHX TextNO INTERVENING ROOMS IN PROJECT
AutoCAD SHX TextALL CORRIDORS MEET MIN. WIDTH AND HEIGHT REQUIREMENTS
AutoCAD SHX TextTABLE 1004.1.2
AutoCAD SHX TextTABLE 1004.1.2
AutoCAD SHX TextTABLE 1004.1.2
AutoCAD SHX Text1009.4
AutoCAD SHX TextTABLE 1021.2(2)
AutoCAD SHX Text1014.2
AutoCAD SHX Text1 UNISEX PROVIDED
AutoCAD SHX TextALL CORRIDORS MEET MIN. WIDTH AND HEIGHT REQUIREMENTS
AutoCAD SHX Text1
AutoCAD SHX Text2
AutoCAD SHX Text4
AutoCAD SHX Text5
AutoCAD SHX Text6
AutoCAD SHX Text7
AutoCAD SHX Text8
AutoCAD SHX Text9
AutoCAD SHX Text10
AutoCAD SHX Text11
AutoCAD SHX Text12
AutoCAD SHX Text13
AutoCAD SHX Text15
AutoCAD SHX Text14
AutoCAD SHX Text16
AutoCAD SHX Text3
AutoCAD SHX TextH
AutoCAD SHX TextG
AutoCAD SHX TextF
AutoCAD SHX TextE
AutoCAD SHX TextD
AutoCAD SHX TextC
AutoCAD SHX TextB
AutoCAD SHX TextA
AutoCAD SHX TextN
AutoCAD SHX TextK
AutoCAD SHX TextJ
AutoCAD SHX TextM
AutoCAD SHX TextL
AutoCAD SHX TextY
AutoCAD SHX Text0
AutoCAD SHX TextR
AutoCAD SHX TextT
AutoCAD SHX Text1
AutoCAD SHX Text7
AutoCAD SHX TextE
AutoCAD SHX TextN
AutoCAD SHX TextA
AutoCAD SHX TextT
AutoCAD SHX TextW
AutoCAD SHX TextR
AutoCAD SHX TextK
AutoCAD SHX Text4
AutoCAD SHX Text4
AutoCAD SHX Text8
AutoCAD SHX TextA
AutoCAD SHX TextL
AutoCAD SHX TextE
AutoCAD SHX TextC
AutoCAD SHX TextN
AutoCAD SHX Text06-07-2017
AutoCAD SHX TextA.M.
AutoCAD SHX TextT.C.
AutoCAD SHX Text16-0613
AutoCAD SHX Text06-05-2017