+ All Categories
Home > Documents > Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs,...

Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs,...

Date post: 23-Mar-2020
Category:
Upload: others
View: 7 times
Download: 0 times
Share this document with a friend
60
Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue
Transcript
Page 1: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

Modular Din rail componentsMCBs, RCDs, meters & surge protection

Short form catalogue

Page 2: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

3 Line Protection Equipment 0115 ABB Low Voltage

Page 3: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

3 Line Protection Equipment 0115 ABB Low Voltage

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/32

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

F 200 AC typeFunction: protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30 mA) contacts; command and isolation of resistive and inductive circuits.

Application: residential, commercial, industrial.

Standard: IEC/EN 61008, UL 1053

Marking: according to EN 61008

Sensitivity in mA Rated current In A Double Pole Price Four Pole Price

10 16 F202 AC-16/0.01 66.67 - -

30 25 F202 AC-25/0.03 51.08 F204 AC-25/0.03 54.17

40 F202 AC-40/0.03 53.93 F204 AC-40/0.03 65.89

63 F202 AC-63/0.03 64.92 F204 AC-63/0.03 93.44

80 F202 AC-80/0.03 80.32 F204 AC-80/0.03 116.23

100 F202 AC-100/0.03 94.21 F204 AC-100/0.03 130.79

100 25 F202 AC-25/0.1 50.73 F204 AC-25/0.1 54.85

40 F202 AC-40/0.1 53.71 F204 AC-40/0.1 62.17

63 F202 AC-63/0.1 58.13 F204 AC-63/0.1 67.23

80 F202 AC-80/0.1 61.94 F204 AC-80/0.1 116.23

100 F202 AC-100/0.1 75.46 F204 AC-100/0.1 130.79

300 25 F202 AC-25/0.3 47.81 F204 AC-25/0.3 53.09

40 F202 AC-40/0.3 48.77 F204 AC-40/0.3 55.09

63 F202 AC-63/0.3 54.80 F204 AC-63/0.3 61.39

80 F202 AC-80/0.3 60.10 F204 AC-80/0.3 116.23

100 F202 AC-100/0.3 72.18 F204 AC-100/0.3 130.79

System ProM CompactRCCB’s F200 series AC type

AC

2CS

C40

0565

F020

12C

SC

4005

69F0

201

ABB SF Section 3.5.indd 3/32 15/2/07 11:36:19 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/36

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProM CompactRCD-blocks DDA 200 series AC type

2CS

C40

0163

F020

12C

SC

4001

64F0

201

2CS

C40

0165

F020

1

ACDDA 200 AC typeFunction: RCD-block for assembly on site with MCBs S 200 series. Protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30 mA) contacts.

Application: residential, commercial, industrial.

Standard: IEC/EN 61009 Ann. G

Rated Current In A: 63A

Rated residual current Double Pole Price Triple Pole Price Four Pole Price

30 DDA202 AC-63/0.032) 55.04 DDA203 AC-63/0.032) 66.50 DDA204 AC-63/0.031)2) 72.69

100 DDA202 AC-63/0.12) 68.07 DDA203 AC-63/0.12) 66.50 DDA204 AC-63/0.12) 72.69

300 DDA202 AC-63/0.32) 57.64 DDA203 AC-63/0.32) 61.53 DDA204 AC-63/0.32) 66.85

1) version with test button working at 115V AC - 127V AC is available on request2) provided with additional terminals for remote tripping

ABB SF Section 3.5.indd 3/36 15/2/07 11:36:23 am

3/66

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

For loads to be automatically controlled through high number of operations; i.e, building automation, controlling of small pumps, ventilations, heating systems, lighting systems, and so on.

ESB series contactorsThe series consists of various models differing in the number of contacts, rated current and control circuit voltage.

ESB20 contactors (20A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

1NO+1NC 12 ESB20-11/12 19.03

1NO+1NC 24 ESB20-11/24 19.03

1NO+1NC 48 ESB20-11/48 19.03

1NO+1NC 110 ESB20-11/110 19.03

1NO+1NC 230 ESB20-11/230 19.03

21CN2 ESB20-02/12 19.03

42CN2 ESB20-02/24 19.03

84CN2 ESB20-02/48 19.93

011CN2 ESB20-02/110 19.93

032CN2 ESB20-02/230 19.93

21ON2 ESB20-20/12 19.93

42ON2 ESB20-20/24 19.03

84ON2 ESB20-20/48 19.03

011ON2 ESB20-20/110 19.03

032ON2 ESB20-20/230 19.03

ESB24 contactors (24A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

21ON4 ESB24-40/12 23.51

42ON4 ESB24-40/24 23.51

032ON4 ESB24-40/230 23.50

2CS

C40

0479

F020

1

2CS

C40

0480

F020

1

ESB40 contactors (40A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

42ON4 ESB40-40/24 41.54

032ON4 ESB40-40/230 41.54

ESB63 contactors (63A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

42ON4 ESB63-40/24 63.70

032ON4 ESB63-40/230 63.70

Auxiliary elements & accessories available for ESB24/40/63, EN24/40

ecirPedoC redrOnoitpircseD

Auxiliary elements2NO EH 04/20 12.44

1NO+1NC EH 04/11 12.44

Other accessoriesSpacer ESB-DIS 0.85

Terminal covers for ESB24 ESB-PLK 24 0.55

Terminal covers for ESB40/63 ESB-PLK 40/63 0.73

2CS

C40

0481

F020

12C

SC

4004

82F0

201

System ProM CompactESB series contactors

ABB SF Section 3.5.indd 3/66 15/2/07 11:37:31 am

Modular Din rail componentsMCBs, RCDs, meters & surge protection

3

3/94 2CSC 400 002 D0211 | System pro M compact®

Residual current relaysRD2

Technical features

Operating voltage [V] 230÷400 a.c. (RD2) and

48÷150 a.c./d.c. (RD2-48)

Frequency [Hz] 50÷60

Type A

Operating temperature [°C] -5…+40

Power consumption [W] <3.4, 230 V a.c.

Sensitivity settings I∆n [A] 0.03; 0.1; 0.3; 0.5; 1; 2

Tripping time settings [s] Fast (instantaneous); 0.3; 0.5; 1; 2; 5

Contact capacity [A] 10 at 250 V a.c. (ohmic)

Contact type NC-C-NO

Modules [No.] 2

Protection degree IP20

Standards IEC/EN 62020

RD2 residual current relaysResidual current relays with external toroidal transformer can detect leakage currents. Through minidip it is possible to set sensitivity and intervention time.

Operating voltage

V

Bbn8012542

EAN

Order details Price1 piece

Weight1 piece

kg

Packunit

pc.Type code Order code

230…400 a.c. 058007 RD2 2CSM142120R1201 0.125 1

48…150 a.c./d.c. 537809 RD2-48 2CSM242120R1201 0.125 1

2CS

C40

0320

F020

1

RD2

Where to find more:Wiring Diagrams for RD2 p.11/8 Technical guide of RCDs (code 2CSC420004B0201)

Maybe you are also interested in:Toroidal Transformers p.3/97

í

íñìè ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ÎÝÞÑ­ ÜÍîðï Ó ­»®·»­ ïðððð ßÝ © ¬§°»ô Ý ½¸¿®¿½¬»®·­¬·½

ÜÍîðï Ó ßÝ ¬§°»ô Ý ½¸¿®¿½¬»®·­¬·½

Ú«²½¬·±²æ °®±¬»½¬·±² ±º »²¼ «­»® ­·²¹´»ó°¸¿­» ½·®½«·¬­ ¿¹¿·²­¬ ±ª»®´±¿¼ ¿²¼ ­¸±®¬ó½·®½«·¬ ½«®ó

®»²¬­å °®±¬»½¬·±² ¿¹¿·²­¬ ¬¸» »ºº»½¬­ ±º ­·²«­±·¼¿´ ¿´¬»®²¿¬·²¹ »¿®¬¸ º¿«´¬ ½«®®»²¬­å °®±¬»½¬·±²

ß°°´·½¿¬·±²æ ®»­·¼»²¬·¿´ô ½±³³»®½·¿´ô ·²¼«­¬®·¿´ò

ͬ¿²¼¿®¼æ ×ÛÝñÛÒ êïððç

×½²ãïð µß

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ïõÒ íð ê çççéðê ÜÍîðï Ó Ýê ßÝíð îÝÍÎîéëðìðÎïðêì ðòîìð ë

ïð çççèðë ÜÍîðï Ó Ýïð ßÝíð îÝÍÎîéëðìðÎïïðì ðòîìð ë

ïí ççççðì ÜÍîðï Ó Ýïí ßÝíð îÝÍÎîéëðìðÎïïíì ðòîìð ë

ïê ïðëêëé ÜÍîðï Ó Ýïê ßÝíð îÝÍÎîéëðìðÎïïêì ðòîìð ë

îð ïðëéëê ÜÍîðï Ó Ýîð ßÝíð îÝÍÎîéëðìðÎïîðì ðòîìð ë

îë ïðëèëë ÜÍîðï Ó Ýîë ßÝíð îÝÍÎîéëðìðÎïîëì ðòîìð ë

íî ïðëçëì ÜÍîðï Ó Ýíî ßÝíð îÝÍÎîéëðìðÎïíîì ðòîìð ë

ìð ïðêðëð ÜÍîðï Ó Ýìð ßÝíð îÝÍÎîéëðìðÎïìðì ðòîìð ë

ïðð ê ïðêçëï ÜÍîðï Ó Ýê ßÝïðð îÝÍÎîéëðìðÎîðêì ðòîìð ë

ïð ïðéðëé ÜÍîðï Ó Ýïð ßÝïðð îÝÍÎîéëðìðÎîïðì ðòîìð ë

ïí ïðéïëê ÜÍîðï Ó Ýïí ßÝïðð îÝÍÎîéëðìðÎîïíì ðòîìð ë

ïê ïðéîëë ÜÍîðï Ó Ýïê ßÝïðð îÝÍÎîéëðìðÎîïêì ðòîìð ë

îð ïðéíëì ÜÍîðï Ó Ýîð ßÝïðð îÝÍÎîéëðìðÎîîðì ðòîìð ë

îë ïðéìëí ÜÍîðï Ó Ýîë ßÝïðð îÝÍÎîéëðìðÎîîëì ðòîìð ë

íî ïðéëëî ÜÍîðï Ó Ýíî ßÝïðð îÝÍÎîéëðìðÎîíîì ðòîìð ë

ìð ïðéêëï ÜÍîðï Ó Ýìð ßÝïðð îÝÍÎîéëðìðÎîìðì ðòîìð ë

íðð ê ïðèëëç ÜÍîðï Ó Ýê ßÝíðð îÝÍÎîéëðìðÎíðêì ðòîìð ë

ïð ïðèêëè ÜÍîðï Ó Ýïð ßÝíðð îÝÍÎîéëðìðÎíïðì ðòîìð ë

ïí ïðèéëé ÜÍîðï Ó Ýïí ßÝíðð îÝÍÎîéëðìðÎíïíì ðòîìð ë

ïê ïðèèëê ÜÍîðï Ó Ýïê ßÝíðð îÝÍÎîéëðìðÎíïêì ðòîìð ë

îð ïðèçëë ÜÍîðï Ó Ýîð ßÝíðð îÝÍÎîéëðìðÎíîðì ðòîìð ë

îë ïðçðëï ÜÍîðï Ó Ýîë ßÝíðð îÝÍÎîéëðìðÎíîëì ðòîìð ë

íî ïðçïëð ÜÍîðï Ó Ýíî ßÝíðð îÝÍÎîéëðìðÎííîì ðòîìð ë

ìð ïðçîëç ÜÍîðï Ó Ýìð ßÝíðð îÝÍÎîéëðìðÎíìðì ðòîìð ë

îÝ

ÍÝ

ìð

ðð

ðë

Úð

îð

î

ÜÍîðï Ó

ɸ»®» ¬± º·²¼ ³±®»æɱ®´¼©·¼» Ó¿®µ­ ¿²¼ ß°°®±ª¿´­ °òïïñçîÌ»½¸²·½¿´ ¹«·¼» ±º ÎÝÜ­ ø½±¼» îÝÍÝìîðððìÞðîðï÷

Ú®»¯«»²¬´§ ¿­µ»¼ ¯«»­¬·±² ó ÚßÏæß ½±³°´»¬» ´·­¬ ±º ¿²­©»®­ ·­ ¿ª¿·´¿¾´» ·² ¬¸» ÎÝÜ­ ÚßÏ ¼±½«³»²¬ ø½±¼» îÝÍÝìîðððëÞðîðï÷

Ó¿§¾» §±« ¿®» ¿´­± ·²¬»®»­¬»¼ ·²æß«¨·´·¿®§ Û´»³»²¬­ º±® ÎÝÜ­ °òìñì ß½½»­­±®·»­ º±® ÎÝÜ­ °òìñïêÞ«­¾¿® ͧ­¬»³­ °òìñîï

í

íñéè ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ÜÜß èðð ßÝ ¬§°» º±® ÓÝÞ­ Íèðð

Ú«²½¬·±²æ ÎÝÜó¾´±½µ º±® ¿­­»³¾´§ ±² ­·¬» ©·¬¸ ÓÝÞ­ Íèðð ­»®·»­ «° ¬± êí ßò Ю±¬»½¬·±²

¿¹¿·²­¬ ¬¸» »ºº»½¬­ ±º ­·²«­±·¼¿´ ¿´¬»®²¿¬·²¹ »¿®¬¸ º¿«´¬ ½«®®»²¬­å °®±¬»½¬·±² ¿¹¿·²­¬ ·²¼·®»½¬ ½±²ó

¬¿½¬­ ¿²¼ ¿¼¼·¬·±²¿´ °®±¬»½¬·±² ¿¹¿·²­¬ ¼·®»½¬ ½±²¬¿½¬­ ø©·¬¸ × ²ãíð ³ß÷ò

ß°°´·½¿¬·±²æ ½±³³»®½·¿´ô ·²¼«­¬®·¿´ò

ͬ¿²¼¿®¼æ ×ÛÝñÛÒ êðçìéóî ß²²ò Þ

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

î íð êí çïçéðì ÜÜßèðîßÝóêíñðòðí îÝÍÞèðîððïÎïêíð ðòíðð ï

íðð êí çïççðî ÜÜßèðîßÝóêíñðòí îÝÍÞèðîððïÎíêíð ðòíðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

í íð êí çîîððï ÜÜßèðíßÝóêíñðòðí îÝÍÞèðíððïÎïêíð ðòìðð ï

íðð êí çîîîðç ÜÜßèðíßÝóêíñðòí îÝÍÞèðíððïÎíêíð ðòìðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ì íð êí çîììðï ÜÜßèðìßÝóêíñðòðí îÝÍÞèðìððïÎïêíð ðòìêð ï

íðð êí çîìêðç ÜÜßèðìßÝóêíñðòí îÝÍÞèðìððïÎíêíð ðòìêð ï

ÎÝÜó¾´±½µ­ ÜÜß èðð ßÝ © ¬§°» º±® ÓÝÞ­ Íèðð

îÝ

ÍÝ

ìð

ðï

éé

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éè

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éç

Úð

îð

ï

ÜÜß èðî

ÜÜß èðí

ÜÜß èðì

ɸ»®» ¬± º·²¼ ³±®»æÌ»½¸²·½¿´ ¹«·¼» ±º ÎÝÜ­ ø½±¼» îÝÍÝìîðððìÞðîðï÷

Ú®»¯«»²¬´§ ¿­µ»¼ ¯«»­¬·±² ó ÚßÏæß ½±³°´»¬» ´·­¬ ±º ¿²­©»®­ ·­ ¿ª¿·´¿¾´» ·² ¬¸» ÎÝÜ­ ÚßÏ ¼±½«³»²¬ ¬ ø½±¼» îÝÍÝìîðððëÞðîðï÷

Ó¿§¾» §±« ¿®» ¿´­± ·²¬»®»­¬»¼ ·²æß«¨·´·¿®§ Û´»³»²¬­ ¿²¼ ß½½»­­±®·»­ º±® Íèðð ¿²¼ ÜÜß èðð °òìñêî

ContentsMCB and earth leakage overview 4Command and control overview 6Measurement overview 8Advantages 10

MCBs 12S200 series 17SN201 series 21S800 series 23

Earth leakage 29F200 series 31DDA200 series 32DS201M series 33DS271 series 34

Accessories 35S200, SN201, F200, DS200 39S800 48Modular devices 49Residual current relays 49

Measurement & protection 50Meters and CTs 50Surge protective devices to BS7671 52

í

íñéè ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ÜÜß èðð ßÝ ¬§°» º±® ÓÝÞ­ Íèðð

Ú«²½¬·±²æ ÎÝÜó¾´±½µ º±® ¿­­»³¾´§ ±² ­·¬» ©·¬¸ ÓÝÞ­ Íèðð ­»®·»­ «° ¬± êí ßò Ю±¬»½¬·±²

¿¹¿·²­¬ ¬¸» »ºº»½¬­ ±º ­·²«­±·¼¿´ ¿´¬»®²¿¬·²¹ »¿®¬¸ º¿«´¬ ½«®®»²¬­å °®±¬»½¬·±² ¿¹¿·²­¬ ·²¼·®»½¬ ½±²ó

¬¿½¬­ ¿²¼ ¿¼¼·¬·±²¿´ °®±¬»½¬·±² ¿¹¿·²­¬ ¼·®»½¬ ½±²¬¿½¬­ ø©·¬¸ × ²ãíð ³ß÷ò

ß°°´·½¿¬·±²æ ½±³³»®½·¿´ô ·²¼«­¬®·¿´ò

ͬ¿²¼¿®¼æ ×ÛÝñÛÒ êðçìéóî ß²²ò Þ

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

î íð êí çïçéðì ÜÜßèðîßÝóêíñðòðí îÝÍÞèðîððïÎïêíð ðòíðð ï

íðð êí çïççðî ÜÜßèðîßÝóêíñðòí îÝÍÞèðîððïÎíêíð ðòíðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

í íð êí çîîððï ÜÜßèðíßÝóêíñðòðí îÝÍÞèðíððïÎïêíð ðòìðð ï

íðð êí çîîîðç ÜÜßèðíßÝóêíñðòí îÝÍÞèðíððïÎíêíð ðòìðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ì íð êí çîììðï ÜÜßèðìßÝóêíñðòðí îÝÍÞèðìððïÎïêíð ðòìêð ï

íðð êí çîìêðç ÜÜßèðìßÝóêíñðòí îÝÍÞèðìððïÎíêíð ðòìêð ï

ÎÝÜó¾´±½µ­ ÜÜß èðð ßÝ © ¬§°» º±® ÓÝÞ­ Íèðð

îÝ

ÍÝ

ìð

ðï

éé

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éè

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éç

Úð

îð

ï

ÜÜß èðî

ÜÜß èðí

ÜÜß èðì

ɸ»®» ¬± º·²¼ ³±®»æÌ»½¸²·½¿´ ¹«·¼» ±º ÎÝÜ­ ø½±¼» îÝÍÝìîðððìÞðîðï÷

Ú®»¯«»²¬´§ ¿­µ»¼ ¯«»­¬·±² ó ÚßÏæß ½±³°´»¬» ´·­¬ ±º ¿²­©»®­ ·­ ¿ª¿·´¿¾´» ·² ¬¸» ÎÝÜ­ ÚßÏ ¼±½«³»²¬ ¬ ø½±¼» îÝÍÝìîðððëÞðîðï÷

Ó¿§¾» §±« ¿®» ¿´­± ·²¬»®»­¬»¼ ·²æß«¨·´·¿®§ Û´»³»²¬­ ¿²¼ ß½½»­­±®·»­ º±® Íèðð ¿²¼ ÜÜß èðð °òìñêî

3/38

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

DS 271 AC type, B and C characteristicsFunction: protection against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts (IΔn=30 mA); command and isolation of resistive and inductive loads.

Application: residential, commercial, industrial.

Standard: IEC/EN 61009 and BSEN61009-2-2

Icn=10 kA

Rated residual current Rated current In A Type B Price Type C Price

30 6 DS271 AC-B6/0.03 55.82 DS271 AC-C6/0.03 55.82

10 DS271 AC-B10/0.03 55.82 DS271 AC-C10/0.03 55.82

16 DS271 AC-B16/0.03 55.82 DS271 AC-C16/0.03 55.82

20 DS271 AC-B20/0.03 55.82 DS271 AC-C20/0.03 55.82

25 DS271 AC-B25/0.03 55.82 DS271 AC-C25/0.03 55.82

32 DS271 AC-B32/0.03 55.82 DS271 AC-C32/0.03 55.82

100 6 - - DS271 AC-C6/0.1 55.82

10 - - DS271 AC-C10/0.1 55.82

16 - - DS271 AC-C16/0.1 55.82

20 - - DS271 AC-C20/0.1 55.82

25 - - DS271 AC-C25/0.1 55.82

32 - - DS271 AC-C32/0.1 55.82

System ProMRCBO’s DS 271 series B & C characteristics - 10kA

B&C

ABB SF Section 3.5.indd 3/38 15/2/07 11:36:28 am

3

3/94 2CSC 400 002 D0211 | System pro M compact®

Residual current relaysRD2

Technical features

Operating voltage [V] 230÷400 a.c. (RD2) and

48÷150 a.c./d.c. (RD2-48)

Frequency [Hz] 50÷60

Type A

Operating temperature [°C] -5…+40

Power consumption [W] <3.4, 230 V a.c.

Sensitivity settings I∆n [A] 0.03; 0.1; 0.3; 0.5; 1; 2

Tripping time settings [s] Fast (instantaneous); 0.3; 0.5; 1; 2; 5

Contact capacity [A] 10 at 250 V a.c. (ohmic)

Contact type NC-C-NO

Modules [No.] 2

Protection degree IP20

Standards IEC/EN 62020

RD2 residual current relaysResidual current relays with external toroidal transformer can detect leakage currents. Through minidip it is possible to set sensitivity and intervention time.

Operating voltage

V

Bbn8012542

EAN

Order details Price1 piece

Weight1 piece

kg

Packunit

pc.Type code Order code

230…400 a.c. 058007 RD2 2CSM142120R1201 0.125 1

48…150 a.c./d.c. 537809 RD2-48 2CSM242120R1201 0.125 1

2CS

C40

0320

F020

1

RD2

Where to find more:Wiring Diagrams for RD2 p.11/8 Technical guide of RCDs (code 2CSC420004B0201)

Maybe you are also interested in:Toroidal Transformers p.3/97

Electronic Systems Protection | Design & technical solut ions 5

Main section boardOVR T1+2 3N 15-255-7 surge protective device – TNS/TT 230/400V 3Ph+N networksType 1+2 ABB surge protective devices have a high impulse current (10/350 waveform) withstand capacity whilst ensuring a low (better) voltage protection level (Up).

Consumer units – Domestic/ResidentialOVR Plus N1 20 self-protected surge protective device - TNS/TT 230 V 1Ph+N networksSelf-protected with integral backup miniature circuit breaker offering dedicated over current protection device (OCPD) fully coordinated with the surge protective device.

Sub-distribution boardOVR T2 3N 40 275s P TS surge protective device - TNS/TT 230/400V 3Ph+N networksType 2 surge protective devices are designed to protect electrical installations and sensitive equipment against indirect surge currents

OVR Plus N3 40 self-protected surge protective device - TNS/TT 230V/400V 3Ph+N networksSelf-protected with integral backup miniature circuit breaker offering dedicated over current protection device (OCPD) fully coordinated with the surge protective device.

28 | ABB System pro M compact®

3

DescriptionType 1 and Type 1+2 surge protective devices are designed to discharge high current surges without any de-struction of the installation. These surge protective devices are characterized by their capacity to withstand impulse current with 10/350 µs wave form which simulate natural lightning current.

Type 1+2 ABB surge protective devices have a high impulse current withstand capacity with ensuring a low protection level (Up).

Type 1 and Type 1+2 SPDs can be installed at the entrance in the main switch board for a global protection of the electrical installation.

Ordering detailsNb of poles

Impulse current

Follow current interrupting rating

Voltage protection level

Nominal voltage

Max. cont. operating voltage

Type Order code EAN code

Weight

Pkg(1 pce)Iimp

10/350 Ifi Up Un UckA kA kV V V 3660308 kg

Follow current interrupting rating 50 kA4 25 50 2.5 230/400 255 OVR T1 4L 25-255 2CTB815101R1400 510914 1.164 25 50 2.5 230/400 255 OVR T1 4L 25-255 TS 2CTB815101R0800 510969 1.263+1 25 50 2.5 230/400 255 OVR T1 3N 25-255 2CTB815101R1600 510938 1.163+1 25 50 2.5 230/400 255 OVR T1 3N 25-255 TS 2CTB815101R0700 510983 1.26

Follow current interrupting rating 7 kA3+1 25 7 2.5 230/400 255 OVR T1 3N 25-255-7 2CTB815101R8800 514127 0.84

OVR Type 1 surge protective devicesTNS/TT 230 V 3Ph+N networks

OVR T1 3N 25-255-7

Type Width

mm inchesOVR T1 4L 25-255 140.0 5.5OVR T1 4L 25-255 TS 157.5 6.2OVR T1 3N 25-255 140.0 5.6OVR T1 3N 25-255 TS 157.5 6.3OVR T1 3N 25-255-7 89.0 3.5

Main dimensions mm

140 157.5

OVR T1 4L 25-255OVR T1 3N 25-255

OVR T1 3N 25-255-7

OVR T1 4L 25-255 TS OVR T1 3N 25-255 TS

56 | ABB System pro M compact®

OVR T2 3N 15-275 P

Type Width

mm inchesOVR T2 3N 15-275 P 71.2 2.80OVR T2 3N 40-275 P 71.2 2.80OVR T2 3N 40-275 P TS 71.2 2.80OVR T2 3N 40-275s P 71.2 2.80OVR T2 3N 40-275s P TS 71.2 2.80OVR T2 3N 70-275s P 71.2 2.80OVR T2 3N 70-275s P TS 71.2 2.80

OVR T2 3N 40-275 P TS OVR T2 3N 40-275s P TS OVR T2 3N 70-275s P TS

OVR T2 3N 15-275 P OVR T2 3N 40-275 P OVR T2 3N 40-275s P OVR T2 3N 70-275s P

Main dimensions mm

3

DescriptionType 2 surge protective devices are designed to protect electric installations and sensitive equipment against indirect surges with ensuring a low protection level (Up). They are characterized by their capacity to safely discharge current with 8/20 µs wave form.

Ordering detailsNb of poles

Max. discharge current

Nominal discharge current

Voltage protection level

Nominal voltage

Max. cont. operating voltage

Type Order code EAN code

Weight

Pkg(1 pce)Imax

8/20 In Up Un Uc

kA kA kV V V 3660308 kg

Type 2 pluggable - Uc 275 V3+1 15 5 1.0 230/400 275 OVR T2 3N 15-275 P 2CTB803953R1200 513151 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275 P 2CTB803953R1100 513267 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275 P TS 2CTB803953R0500 514394 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275s P 2CTB803953R0800 513144 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275s P TS 2CTB803953R0200 513120 0.453+1 70 30 1.5 230/400 275 OVR T2 3N 70-275s P 2CTB803953R0700 513137 0.453+1 70 30 1.5 230/400 275 OVR T2 3N 70-275s P TS 2CTB803953R0100 513113 0.45

OVR Type 2 surge protective devicesTNS/TT 230 V 3Ph+N networks

62 | ABB System pro M compact®

OVR PLUS N3 20OVR PLUS N3 40

Type Width

mm inchesOVR PLUS N1 20 35.6 1.40OVR PLUS N1 40 35.6 1.40OVR PLUS N3 20 106.8 4.20OVR PLUS N3 40 106.8 4.20

OVR Plus N3 20OVR Plus N3 40

OVR Plus N1 20OVR Plus N1 40

3

DescriptionOVR PLUS N3 20 and OVR PLUS N3 40 for commercial and industrial applications: – Auto-protected: Backup miniature circuit breaker integrated and fully coordinated with the surge protective device.

– Easy installation: Fully coordinated unit with easy wiring with the complete ABB pro M modular range. – High discharge capacity: With Imax 20 and 40 kA the OVR Plus N3 insure the protection of your low voltage installations and electric equipment.

– High reliability: No welding inside the module and specific thermal disconnection with the "bilame" sensor.

OVR PLUS N1 40 for residential applications: – Auto-protected: Backup miniature circuit breaker integrated and fully coordinated with the surge protective device.

– Compact: Only two modules (36 mm width), means more space and easy wiring with the complete ABB DIN rail range.

– High discharge capacity: With Imax 20 and 40 kA the OVR PLUS N1 can protect your electric equipment against high surges.

– High reliability: No welding inside the module and specific thermal disconnection.

Ordering detailsProtected lines

Max. discharge current

Nominal current

Voltage protection level

Nominal voltage

Max. cont. operating voltage

Type Order code EAN code

Weight

Pkg(1 pce)Imax

8/20 In Up Un Uc

kA kA kV V V 3660308 kg

Type 2 autoprotected1+1 20 5 1.3 230/400 275 OVR PLUS N1 20 2CTB803701R0700 521286 0.281+1 40 20 1.8 230/400 320 OVR PLUS N1 40 2CTB803701R0100 517005 0.283+1 20 5 1.3 230/400 320 OVR PLUS N3 20 2CTB803701R0400 517081 0.843+1 40 20 2.0 230/400 320 OVR PLUS N3 40 2CTB803701R0300 517074 0.84

OVR Plus - Autoprotected surge protective devicesTNS/TT 230 V networks

Main dimensions mm

– Multi-mode protection – End of life SPD visual indicator – DIN rail mounting for quick installation – Compact design

– Multi-mode protection – DIN rail mounting for quick installation – Fully coordinated unit for optimised installation and simplified wiring – High reliability – Innovative, weld-free safe thermal disconnection sensor – Compact design

– Multi-mode protection – End of life SPD visual indicator – Plug-in cartridge – DIN rail mounting for quick installation – Auxiliary contact TS for remote status indication

– Multi-mode protection – DIN rail mounting for quick installation – High reliability – Innovative, weld-free safe thermal disconnection sensor – Fully compatible with the complete ABB pro M modular range

ABB LV Panel SPDsCommercial, Industrial & Domestic Installations

ABB’s wide range of mains SPDs compliment the power DIN-rail product range, providing protection to the electrical installation at any point in the mains distribution system.

Characteristics

Characteristics

Characteristics

Characteristics

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax20 kA

OCPDINTEGRATEDMODULE

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

3/68

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

TW twilight switches with sensor LS-SPThey allow to switch on and/or switch off lighting devices according to the preset ambient light level. They are used in combination with a sensor detecting if ambient light level is higher or lower than the preset threshold. The versions with built-in time switch allow the control of the lighting system in relation to the ambient light level combined with a specifi c time program. All the TWS twilight switches are supplied together with wall mounting sensor.

Channels Order Code Price

1 TWS-1M 97.80

System ProM CompactTW twilight switches

Accessories for TWLS-1 sensor is the same wall mounting sensor which is included in each TWS twilight switch package and it is available as spare part.

Order Code Price

Spare wall mounting sensor AOP1-SL

2CS

C40

0544

F020

1

ABB SF Section 3.5.indd 3/68 15/2/07 11:37:34 am

Page 4: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

4 Line Protection Equipment 0115 ABB Low Voltage 5 Line Protection Equipment 0115 ABB Low Voltage

The best solution for every applicationMCB, earth leakage and surge protection

1

1/8 2CSC 400 002 D0211 | System pro M compact®

The best solution for every applicationA world of advantages

Miniature circuit-brakers Residual Current protectio

Increased terminal opening for higher wire gauges up to 35mm².For conductors with or without connector sleeves.Fulfills still the requirements for protection de-gree IP20 (finger safe) acc. to IEC/EN 60529.Integrated plate protecting flexible cables from damage and homogenous pressure in the termi-nal opening.

Switch with intermediate trip position (TRIP).S800 circuit breakers diffe-rentiate manual actuation from over-current trip.

Terminal on the front face for fail-safe function.

Label-holder built into SN200 circuit breakers.Easy identification of protected circuits.One pole plus neutral in a width of just 17.6 mm.

Failsafe bi-directional cylinder-lift terminal at top and bottom (available for the entire System pro M compact range). Ideal for connection of cables and busbars simultaneously.

Multiple certification marks visible on the upper and lower face of the S200 circuit breakers.Laser marking for reliable readability.Real contact position indication, directly connected to the moving contact, for more comfort and safety. Individual identification code for each MCB on the front.

The green/red switch co-lour clearly indicates the connected/disconnected status.

1 2

3

4 5

S200 Series

Circuit breakers up to 63 AS200, S200M and S200P: For residential, commercial and industrial use up to 25 kA. S200U, S200UP and SU-200PR with certification acc. to: Certification UL489/CSA 22.2 No. 5 (US and Canada).

1

SN201 Series

SN201 series circuit breakers including one pole and neutral in one module width up to 40A specific for household applications and tertiary sector.

2

3 S800 Series

S800 circuit breakers with high breaking capacity up to 125AS800B : 16 kA breaking capacity.S800C : 25 kA breaking capacity.S800N : 36 kA breaking capacity.S800S : 50 kA breaking capacity.

5 DDA200 and DDA800 Series

RCD blocks adaptable to the S200 and S800 circuit-breaker series up to 63A and 100A respectively.

4 F200 Series

Residual current devices up to 125 AF200: Residential, tertiary and indus-trial.

System pro M compact® | 2CSC 400 002 D0211 1/9

1Other protection devices

Blown fuse indicator light on the front part of the E90 fuseholder.

Displays the cause of the trip of the DS200 residual current breaker.Blue (residual currentl trip) or black (over-current trip indications).

Contact position indicator visible on the front of the DS200 residual current breaker.

Visual indicator of the remaining life of the OVR surge protective device.Option to include remote signalling contacts of the OVR status.

Includes RFID label.Prevents forgeries through the inclusion of a serial number in compliance with the ISO/IEC FCD 15693-3 standard.

6 7 8 9

7 RD3 residual current relays

Residual current relays with the possibility to set sensitivity and intervention time.Ideal to obtain time and sensitivity combinations and to achieve selectivity with other residual current devices.

9 E90 fuseholders and fuse

disconnectors

E90: Disconnector series up to 32A. E90h: Compact series up to 32A.E930: Series up to 125A.

6 DS200 Series

Circuit breakers and residual current protec-tion in a single device, just two modules width.Suitable for residential, tertiary and industrial applications.

8 OVR series surge protective

devices

Protection of electrical equipment against surges caused by lightning or other grid disruptions.

onS200 Series S800 Series F200 Series

DDA200 and DDA800 Series

SN201 Series

1 3 4

5

2

1 2

3

4 5

Page 5: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

4 Line Protection Equipment 0115 ABB Low Voltage 5 Line Protection Equipment 0115 ABB Low Voltage

1

1/8 2CSC 400 002 D0211 | System pro M compact®

The best solution for every applicationA world of advantages

Miniature circuit-brakers Residual Current protectio

Increased terminal opening for higher wire gauges up to 35mm².For conductors with or without connector sleeves.Fulfills still the requirements for protection de-gree IP20 (finger safe) acc. to IEC/EN 60529.Integrated plate protecting flexible cables from damage and homogenous pressure in the termi-nal opening.

Switch with intermediate trip position (TRIP).S800 circuit breakers diffe-rentiate manual actuation from over-current trip.

Terminal on the front face for fail-safe function.

Label-holder built into SN200 circuit breakers.Easy identification of protected circuits.One pole plus neutral in a width of just 17.6 mm.

Failsafe bi-directional cylinder-lift terminal at top and bottom (available for the entire System pro M compact range). Ideal for connection of cables and busbars simultaneously.

Multiple certification marks visible on the upper and lower face of the S200 circuit breakers.Laser marking for reliable readability.Real contact position indication, directly connected to the moving contact, for more comfort and safety. Individual identification code for each MCB on the front.

The green/red switch co-lour clearly indicates the connected/disconnected status.

1 2

3

4 5

S200 Series

Circuit breakers up to 63 AS200, S200M and S200P: For residential, commercial and industrial use up to 25 kA. S200U, S200UP and SU-200PR with certification acc. to: Certification UL489/CSA 22.2 No. 5 (US and Canada).

1

SN201 Series

SN201 series circuit breakers including one pole and neutral in one module width up to 40A specific for household applications and tertiary sector.

2

3 S800 Series

S800 circuit breakers with high breaking capacity up to 125AS800B : 16 kA breaking capacity.S800C : 25 kA breaking capacity.S800N : 36 kA breaking capacity.S800S : 50 kA breaking capacity.

5 DDA200 and DDA800 Series

RCD blocks adaptable to the S200 and S800 circuit-breaker series up to 63A and 100A respectively.

4 F200 Series

Residual current devices up to 125 AF200: Residential, tertiary and indus-trial.

System pro M compact® | 2CSC 400 002 D0211 1/9

1Other protection devices

Blown fuse indicator light on the front part of the E90 fuseholder.

Displays the cause of the trip of the DS200 residual current breaker.Blue (residual currentl trip) or black (over-current trip indications).

Contact position indicator visible on the front of the DS200 residual current breaker.

Visual indicator of the remaining life of the OVR surge protective device.Option to include remote signalling contacts of the OVR status.

Includes RFID label.Prevents forgeries through the inclusion of a serial number in compliance with the ISO/IEC FCD 15693-3 standard.

6 7 8 9

7 RD3 residual current relays

Residual current relays with the possibility to set sensitivity and intervention time.Ideal to obtain time and sensitivity combinations and to achieve selectivity with other residual current devices.

9 E90 fuseholders and fuse

disconnectors

E90: Disconnector series up to 32A. E90h: Compact series up to 32A.E930: Series up to 125A.

6 DS200 Series

Circuit breakers and residual current protec-tion in a single device, just two modules width.Suitable for residential, tertiary and industrial applications.

8 OVR series surge protective

devices

Protection of electrical equipment against surges caused by lightning or other grid disruptions.

on

RD3 residual current relays

DS200 Series OVR series surge protective devices

OVR series surge protective devices

OVR series surge protective devices

E90 fuseholders and fusedisconnectors

7

6 8

9

6 7 8 9

Page 6: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

6 Line Protection Equipment 0115 ABB Low Voltage 7 Line Protection Equipment 0115 ABB Low Voltage

The best solution for every applicationCommand and control

1

1/10 2CSC 400 002 D0211 | System pro M compact®

The best solution for every applicationA world of advantages

Command and control

Up to 3 E219 LED indicator lights in a width of just 9 mm.LED indicators guarantee an optimal illumination with very low consumption.

Extremely quiet.Variety of control voltages.Multiple combinations of NO and NC con-tacts.Function modes selector: Automatic/Manual/Disconnected (EN series).

Currents up to 125A.From 1 to 4 poles.Option to include an add-on of up to 3 auxiliary contacts.

Multiple command and control functions in the ultra-compact design (9mm width) of the E210 series.

10 11 12 12 12 12 12 12 13

13 D-Line digital and

AT analogue time switches

D1 and D2 weekly digital time switches.D365 yearly digital time switches.AT analogue time switches.

10 Contactors, latching relays

and installation relays

ESB and EN series contactors.E259 series installation relays.E250 and E260 series latching relays.

12 E210 series on-off switches,

push buttons and indicator lamps

E211 and E218 series on-off switches.E213 series change over switches.E214 series group switches.E215 and E217 series push buttons.E219 series single, double and triple indicator lights.11 E200 series

switch disconnectors

From 1 to 4 poles.Up to 125 A.

System pro M compact® | 2CSC 400 002 D0211 1/11

1

D-Line series weekly and annual digi-tal time switches.Multiple communication options.Wide range of programs: standard, cyclic, casual and holiday.White backlit LCD display.

Connection and disconnection time delays.Continuous and impulse signals among multiple options.

Easy to program.Ideal for public lighting, stores ligh-ting, monuments, etc.

13 13 14 14 15

15

14 TWA astronomical switches

and TW twilight switches

TWA astronomical switches to activate lighting systems according to the rising and setting of the sun.TW twilight switches to control lighting devices according to the level of the ambient light.

15 E234 series electronic timers

and E232 series staircase switches

Wide range of E234.E232 staircase timers for household applications.

Contactors, latching relaysand installation relays

E210 series on-off switches,push buttons and indicator lamps

D-Line digital andAT analogue time switches

E200 seriesswitch disconnectors

10 12

12

11

10 11 12 12 12 12 12 12 13

Page 7: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

6 Line Protection Equipment 0115 ABB Low Voltage 7 Line Protection Equipment 0115 ABB Low Voltage

1

1/10 2CSC 400 002 D0211 | System pro M compact®

The best solution for every applicationA world of advantages

Command and control

Up to 3 E219 LED indicator lights in a width of just 9 mm.LED indicators guarantee an optimal illumination with very low consumption.

Extremely quiet.Variety of control voltages.Multiple combinations of NO and NC con-tacts.Function modes selector: Automatic/Manual/Disconnected (EN series).

Currents up to 125A.From 1 to 4 poles.Option to include an add-on of up to 3 auxiliary contacts.

Multiple command and control functions in the ultra-compact design (9mm width) of the E210 series.

10 11 12 12 12 12 12 12 13

13 D-Line digital and

AT analogue time switches

D1 and D2 weekly digital time switches.D365 yearly digital time switches.AT analogue time switches.

10 Contactors, latching relays

and installation relays

ESB and EN series contactors.E259 series installation relays.E250 and E260 series latching relays.

12 E210 series on-off switches,

push buttons and indicator lamps

E211 and E218 series on-off switches.E213 series change over switches.E214 series group switches.E215 and E217 series push buttons.E219 series single, double and triple indicator lights.11 E200 series

switch disconnectors

From 1 to 4 poles.Up to 125 A.

System pro M compact® | 2CSC 400 002 D0211 1/11

1

D-Line series weekly and annual digi-tal time switches.Multiple communication options.Wide range of programs: standard, cyclic, casual and holiday.White backlit LCD display.

Connection and disconnection time delays.Continuous and impulse signals among multiple options.

Easy to program.Ideal for public lighting, stores ligh-ting, monuments, etc.

13 13 14 14 15

15

14 TWA astronomical switches

and TW twilight switches

TWA astronomical switches to activate lighting systems according to the rising and setting of the sun.TW twilight switches to control lighting devices according to the level of the ambient light.

15 E234 series electronic timers

and E232 series staircase switches

Wide range of E234.E232 staircase timers for household applications.

TWA astronomical switchesand TW twilight switches

E234 series electronic timersand E232 series staircase switches

14 15

13 13 14 14 15

15

Page 8: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

8 Line Protection Equipment 0115 ABB Low Voltage 9 Line Protection Equipment 0115 ABB Low Voltage

The best solution for every applicationMeasurement

1

1/12 2CSC 400 002 D0211 | System pro M compact®

The best solution for every applicationA world of advantages

Measurement

Single-phase and three-phase metering.Direct reading up to 80A or indirect reading through current and/or voltage transformers.High precision with an accuracy class up to 0.5.Reading of generated/consumed and active/reac-tive energy.Up to four tariffs.Up to eight channels of load profiles.Previous values for several quantities.Possibility of built-in serial communication inter-faces.Multiple communication options.Possibility of internal clock for advanced functio-nalities.

C11 single-phase digital electricity meter with ultra-compact design just one module wide.C13 three-phase digital meter with ultra-compact design just three modules wide.Both unique on the market.

16 16 17 17

16 EQ digital electricity meters

C series, extremely compact meters.B series, compact with communi-cation features.A series, functionality beyond comparison.Functionalities associated to a “metal scale” assigned to each model (steel, bronze, silver, gold and platinum).

17 Digital and analogue

measuring instruments

AMTD and AMT ammeters.VLMD and VLM voltmeters.FRZ frequency meters.DMTME multimeters.E233 and HTM hour counters.Current and voltage transformers.

System pro M compact® | 2CSC 400 002 D0211 1/13

1Other functions

The range includes products complying with the most widespread standards (German, Italian, French...).Different colours for easy identification.Safety shutters and optional cover.

18 18

18 Extensive range of other

modular devices

Modular sockets.Light dimmers.Priority switches and overload relays.Control, isolating and safety transformers.etc.

18 18

EQ digital electricity meters Digital and analoguemeasuring insruments

16 17

16 16 17 17

Page 9: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

8 Line Protection Equipment 0115 ABB Low Voltage 9 Line Protection Equipment 0115 ABB Low Voltage

1

1/12 2CSC 400 002 D0211 | System pro M compact®

The best solution for every applicationA world of advantages

Measurement

Single-phase and three-phase metering.Direct reading up to 80A or indirect reading through current and/or voltage transformers.High precision with an accuracy class up to 0.5.Reading of generated/consumed and active/reac-tive energy.Up to four tariffs.Up to eight channels of load profiles.Previous values for several quantities.Possibility of built-in serial communication inter-faces.Multiple communication options.Possibility of internal clock for advanced functio-nalities.

C11 single-phase digital electricity meter with ultra-compact design just one module wide.C13 three-phase digital meter with ultra-compact design just three modules wide.Both unique on the market.

16 16 17 17

16 EQ digital electricity meters

C series, extremely compact meters.B series, compact with communi-cation features.A series, functionality beyond comparison.Functionalities associated to a “metal scale” assigned to each model (steel, bronze, silver, gold and platinum).

17 Digital and analogue

measuring instruments

AMTD and AMT ammeters.VLMD and VLM voltmeters.FRZ frequency meters.DMTME multimeters.E233 and HTM hour counters.Current and voltage transformers.

System pro M compact® | 2CSC 400 002 D0211 1/13

1Other functions

The range includes products complying with the most widespread standards (German, Italian, French...).Different colours for easy identification.Safety shutters and optional cover.

18 18

18 Extensive range of other

modular devices

Modular sockets.Light dimmers.Priority switches and overload relays.Control, isolating and safety transformers.etc.

18 18

Extensive range of othermodular devices

18

18 18 18

Other functions

18

(English, German, French, Italian...)

Page 10: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

10 Line Protection Equipment 0115 ABB Low Voltage 11 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactAdvantages

1

1/16 2CSC 400 002 D0211 | System pro M compact®

System pro M compact® Advantages

Supply from top or bottom either with cables or busbars.

Universal signal/auxiliary and auxiliary contacts fit on S 200, F 200 and DS 200.

RCD-blocks DDA 200 2P, 3P, 4P up to 40 A fit into two modules. Versions in 63 A sizes are supplied with two additional terminals for remote tripping.

Availability of a wide range of RCBOs.

Safety connections between DDA 200 and S 200 thanks to a safe plastic key system.

MCBs are also available with an integra-ted auxiliary contact (1 NO or 1 NC). Existing installations can be easily upgraded to include auxili-ary switch functionality.

The System pro M compact® range offers enormous advantages in relation to installation. Advanced and smart solutions allow a far easier and safer installation and guarantee time saving.

The System pro M compact® range offers enormous advantages in relation toinstallation. Advanced and smart solutions allow a far easier and safer installation andguarantee time saving.

Page 11: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

10 Line Protection Equipment 0115 ABB Low Voltage 11 Line Protection Equipment 0115 ABB Low Voltage

System pro M compact® | 2CSC 400 002 D0211 1/17

1

More working space between compo-nent rows.

Special quick fastening for an easy removal of the devices from the assem-bly pressing upwards, both for MCBs S 200 and RCCBs F 200: the only in the market that can be removed without a screwdriver.

Without busbars two terminal spaces can be used for cables with different cross sections: incoming supply with supplementary terminal up to 50 mm2 from the front side.

The bi-directional cylinder-lift terminal allows easier and quicker connections. In addition it avoids errors because it prevents the use of free cable seats.

This high protection level against errors eliminates right from the start industrial accidents deriving from incorrect wiring.

The terminal guarantees a very high tightening torque for cables with a section up to 25 mm2.

The housing of connection busbars in the rear seat guaran-tees easier wiring.

Safe terminal technology: the terminals offer protection from misconnection.

Error proof terminals: they avoid the use of free cable seats.

Supply from top or bottom also possible with busbars.

Page 12: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

12 Line Protection Equipment 0115 ABB Low Voltage 13 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactMCB introduction

Twin terminal for separate feeding of busbar and conductor

Easy identifcation of the product and highly resistant laser marking

Easy product name, easy identification, easy life

Contact position indication

IP20 safe finger protection

Save your time, all data is available right away

Quick identification thanks to laser printed EAN marking

Wide range of accessories available

Captive screws:don’t loose what’s important for you

Page 13: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

12 Line Protection Equipment 0115 ABB Low Voltage 13 Line Protection Equipment 0115 ABB Low Voltage

î

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï îñïë

ß°°®±ª¿´­ °®·²¬»¼ ±² ¬¸» ¼±³»

Í îðð ÓÝÞ­ ½±³°´§ ¬± ×ÛÝñÛÒ êðèçèóï

¿²¼ ×ÛÝñÛÒ êðçìéóî ¿²¼ ½¿®®§ ¿´´

®»´»ª¿²¬ ¿°°®±ª¿´ ³¿®µ­ º±® »¿½¸ ³¿®µ»¬

¿²¼ ­»¹³»²¬ ¬¸»§ ¿®» ¼»­¬·²»¼ ¬±ò ̸»

½»®¬·º·½¿¬·±² ³¿®µ·²¹­ ¿®» ¿´­± °®·²¬»¼

±² ¬¸» ¼±³» ±º ¬¸» ÓÝÞò ̸«­ ³¿µ»

·¬ °±­­·¾´» ¬± ­»» ¬¸» ³¿®µ·²¹­ ¿´­± ·²

¬¸» ³±«²¬»¼ °±­·¬·±²ò Ú±® ½±²¬®±´ ¿²¼

¿½½»°¬¿²½» °®±½»¼«®» ½»®¬·º·½¿¬·±²

³¿®µ­ ª·­·¾´» ±² º·¬¬»¼ ¼»ª·½»­ ±² ¬¸»

¼±³»ò

ر«­·²¹ ³¿¬»®·¿´

Þ§ «­·²¹ ¬¸» ­¬¿¬»ó±ºó¬¸»ó¿®¬ ¸±«­·²¹

³¿¬»®·¿´ô ßÞÞ ·­ ¬¿µ·²¹ ½¿®» ±º ¬¸»

»²ª·®±²³»²¬ò É·¬¸ ¬¸» ´¿¬»­¬ ¹»²»®¿¬·±²

±º ¬¸»®³±°´¿­¬·½­ ·¬­ °±­­·¾´» ¬± ®»½§½´»

¬¸» ÓÝÞ­ »­°»½·¿´´§ ¬¸» ¬¸»®³±°´¿­¬·½

¸±«­·²¹ó³¿¬»®·¿´ ½¿² ¾» ®»ó«­»¼ò Þ§

«­·²¹ ¬¸» ´¿¬»­¬ ¹»²»®¿¬·±² ±º ¬¸»®³±ó

°´¿­¬·½­ ¬¸» ³¿¬»®·¿´ ­¬¿¾·´·¬§ ±º ¿´´ ͧ­ó

¬»³ °®± Ó ½±³°¿½¬r ÓÝÞ­ ·­ ·³°®±ª»¼ò

Íîðð ¿®» ïððû º®»» ±º ¸¿´±¹»²­ ²±

»²ª·®±²³»²¬¿´

°±´´«¬·±²ò

ݱ²¬¿½¬ °±­·¬·±² ·²¼·½¿¬·±²

ß´´ ͧ­¬»³ °®± Ó ½±³°¿½¬r ÓÝÞ­ ¿®»

­«·¬»¼ ©·¬¸ ¿ ½±²¬¿½¬ °±­·¬·±² ·²¼·½¿¬·±²

øÝÐ×÷ ±² ¬¸» ¬±¹¹´»ò DZ« ½¿² »¿­·´§ ·¼»²ó

¬·º§ô ·º ¬¸» ÓÝÞ ·­ ·² ¬¸» ÑÒ ±® ¬¸» ÑÚÚ

°±­·¬·±² »¿­§ ¿²¼ ­¿º» ³¿·²¬»²¿²½»

©±®µ ·­ °±­­·¾´»ò

ͽ®»©´»­­ ¬»®³·²¿´­

É·¬¸ ·¬­ «²·¯«» ¬»®³·²¿´ ­½®»©´»­­ ¬»½¸ó

²±´±¹§ ¬¸» Í îðð Í °®±ª·¼»­ ³¿¨·³«³

º´»¨·¾·´·¬§ ·² «­¿¹» ±º ½¿¾´»­ò ̸» ­½®»©ó

´»­­ ´±¿¼ ­·¼» ¬»®³·²¿´ »²¿¾´»­ º¿­¬

·²­¬¿´´¿¬·±²ò Ø·¹¸ º±®½»­ ·² ¬¸» ­½®»©´»­­

¬»®³·²¿´ ­¿º» ¬·³» º±® ®»¬·¹¸¬»²·²¹ ¿º¬»®

¬®¿²­°±®¬ ±º ¬¸» ¿­­»³¾´»¼ »²½´±­«®»ò

׺ ¬¸» ©·®·²¹ ¸¿­ ¬± ¾» ½¸¿²¹»¼ ±²´§ ¿

­±º¬ °«­¸ ±² ¬¸» ´»ª»® ·­ ®»¯«·®»¼ò

Í îðð Í °®±ª·¼»­ ¬¸» ¸·¹¸»­¬ ­¬¿²¼¿®¼

±º ­¿º»¬§ º±® ·²­¬¿´´»®ò

×Ðîð ñ ×ÐÈÈÞ øº·²¹»® ­¿º»÷ ¸·¹¸»­¬ ­¬¿²ó

¼¿®¼ ±º ¬±«½¸ °®±¬»½¬·±²ò

×Ð îð ó º·²¼»® ­¿º» ¬»®³·²¿´­

̸» ͧ­¬»³ °®± Ó ½±³°¿½¬r ÓÝÞ­ ¿®»

»¯«·°»¼ ©·¬¸ íë ³³n õ ïð ³³n ½§´·²¼»®

´·º¬ ¬©·² ¬»®³·²¿´­ô ¿ ©»´´ °®±ª»² ¿²¼ ®»ó

´·¿¾´» ¬»½¸²±´±¹§ ó ¼»­·¹²»¼ º±® ­±°·­¬·ó

½¿¬»¼ ·²¼«­¬®·¿´ «­»ò

̸» ½®±­­ ©·®·²¹ ½¿² »¿­·´§ ¾» ¼±²» ¾§

·²­»®¬·²¹ ¬¸» ͧ­¬»³ °®± Ó ½±³°¿½¬r

¾«­¾¿®­ ·²¬± ¬¸» ®»¿® ¬»®³·²¿´ °¿®¬ ¿²¼

¬¸»² ¬¸» ·²½±³·²¹ ©·®»­ ·²¬± ¬¸» º®±²¬

°¿®¬ ±º ¬¸» ¬»®³·²¿´ò

Ô¿­»® °®·²¬·²¹

ß´´ °®·²¬·²¹­ ±º ¬¸» Í îðð ¿²¼ Í îðð Ó

ÓÝÞ­ô ´·µ» ¬¸» ¿°°®±ª¿´­ ±² ¬¸» ¼±³»

¿²¼ ¬¸» °®±¼«½¬ ·¼»²¬·º·½¿¬·±²ô ¿®» °®·²ó

¬»¼ ¾§ ¿ ´¿­»®ò ̸» ´¿­»® °®·²¬·²¹ »²­«®»­

¿ º®·½¬·±²ô ­½®¿¬½¸ ¿²¼ ­±´ª»²¬ ®»­·­¬¿²¬

³¿®µ·²¹ ±² ¬¸» ÓÝÞ­ò

Û¿­§ ·¼»²¬·º·½¿¬·±² ±º ¬¸» °®±¼«½¬­ ·²

½¿­» ±º ³¿·²¬»²¿²½» ±® ®»°´¿½»³»²¬­

¼«» ¬± ­¿º» ´¿­»® °®·²¬·²¹ò

î

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï îñïë

ß°°®±ª¿´­ °®·²¬»¼ ±² ¬¸» ¼±³»

Í îðð ÓÝÞ­ ½±³°´§ ¬± ×ÛÝñÛÒ êðèçèóï

¿²¼ ×ÛÝñÛÒ êðçìéóî ¿²¼ ½¿®®§ ¿´´

®»´»ª¿²¬ ¿°°®±ª¿´ ³¿®µ­ º±® »¿½¸ ³¿®µ»¬

¿²¼ ­»¹³»²¬ ¬¸»§ ¿®» ¼»­¬·²»¼ ¬±ò ̸»

½»®¬·º·½¿¬·±² ³¿®µ·²¹­ ¿®» ¿´­± °®·²¬»¼

±² ¬¸» ¼±³» ±º ¬¸» ÓÝÞò ̸«­ ³¿µ»

·¬ °±­­·¾´» ¬± ­»» ¬¸» ³¿®µ·²¹­ ¿´­± ·²

¬¸» ³±«²¬»¼ °±­·¬·±²ò Ú±® ½±²¬®±´ ¿²¼

¿½½»°¬¿²½» °®±½»¼«®» ½»®¬·º·½¿¬·±²

³¿®µ­ ª·­·¾´» ±² º·¬¬»¼ ¼»ª·½»­ ±² ¬¸»

¼±³»ò

ر«­·²¹ ³¿¬»®·¿´

Þ§ «­·²¹ ¬¸» ­¬¿¬»ó±ºó¬¸»ó¿®¬ ¸±«­·²¹

³¿¬»®·¿´ô ßÞÞ ·­ ¬¿µ·²¹ ½¿®» ±º ¬¸»

»²ª·®±²³»²¬ò É·¬¸ ¬¸» ´¿¬»­¬ ¹»²»®¿¬·±²

±º ¬¸»®³±°´¿­¬·½­ ·¬­ °±­­·¾´» ¬± ®»½§½´»

¬¸» ÓÝÞ­ »­°»½·¿´´§ ¬¸» ¬¸»®³±°´¿­¬·½

¸±«­·²¹ó³¿¬»®·¿´ ½¿² ¾» ®»ó«­»¼ò Þ§

«­·²¹ ¬¸» ´¿¬»­¬ ¹»²»®¿¬·±² ±º ¬¸»®³±ó

°´¿­¬·½­ ¬¸» ³¿¬»®·¿´ ­¬¿¾·´·¬§ ±º ¿´´ ͧ­ó

¬»³ °®± Ó ½±³°¿½¬r ÓÝÞ­ ·­ ·³°®±ª»¼ò

Íîðð ¿®» ïððû º®»» ±º ¸¿´±¹»²­ ²±

»²ª·®±²³»²¬¿´

°±´´«¬·±²ò

ݱ²¬¿½¬ °±­·¬·±² ·²¼·½¿¬·±²

ß´´ ͧ­¬»³ °®± Ó ½±³°¿½¬r ÓÝÞ­ ¿®»

­«·¬»¼ ©·¬¸ ¿ ½±²¬¿½¬ °±­·¬·±² ·²¼·½¿¬·±²

øÝÐ×÷ ±² ¬¸» ¬±¹¹´»ò DZ« ½¿² »¿­·´§ ·¼»²ó

¬·º§ô ·º ¬¸» ÓÝÞ ·­ ·² ¬¸» ÑÒ ±® ¬¸» ÑÚÚ

°±­·¬·±² »¿­§ ¿²¼ ­¿º» ³¿·²¬»²¿²½»

©±®µ ·­ °±­­·¾´»ò

ͽ®»©´»­­ ¬»®³·²¿´­

É·¬¸ ·¬­ «²·¯«» ¬»®³·²¿´ ­½®»©´»­­ ¬»½¸ó

²±´±¹§ ¬¸» Í îðð Í °®±ª·¼»­ ³¿¨·³«³

º´»¨·¾·´·¬§ ·² «­¿¹» ±º ½¿¾´»­ò ̸» ­½®»©ó

´»­­ ´±¿¼ ­·¼» ¬»®³·²¿´ »²¿¾´»­ º¿­¬

·²­¬¿´´¿¬·±²ò Ø·¹¸ º±®½»­ ·² ¬¸» ­½®»©´»­­

¬»®³·²¿´ ­¿º» ¬·³» º±® ®»¬·¹¸¬»²·²¹ ¿º¬»®

¬®¿²­°±®¬ ±º ¬¸» ¿­­»³¾´»¼ »²½´±­«®»ò

׺ ¬¸» ©·®·²¹ ¸¿­ ¬± ¾» ½¸¿²¹»¼ ±²´§ ¿

­±º¬ °«­¸ ±² ¬¸» ´»ª»® ·­ ®»¯«·®»¼ò

Í îðð Í °®±ª·¼»­ ¬¸» ¸·¹¸»­¬ ­¬¿²¼¿®¼

±º ­¿º»¬§ º±® ·²­¬¿´´»®ò

×Ðîð ñ ×ÐÈÈÞ øº·²¹»® ­¿º»÷ ¸·¹¸»­¬ ­¬¿²ó

¼¿®¼ ±º ¬±«½¸ °®±¬»½¬·±²ò

×Ð îð ó º·²¼»® ­¿º» ¬»®³·²¿´­

̸» ͧ­¬»³ °®± Ó ½±³°¿½¬r ÓÝÞ­ ¿®»

»¯«·°»¼ ©·¬¸ íë ³³n õ ïð ³³n ½§´·²¼»®

´·º¬ ¬©·² ¬»®³·²¿´­ô ¿ ©»´´ °®±ª»² ¿²¼ ®»ó

´·¿¾´» ¬»½¸²±´±¹§ ó ¼»­·¹²»¼ º±® ­±°·­¬·ó

½¿¬»¼ ·²¼«­¬®·¿´ «­»ò

̸» ½®±­­ ©·®·²¹ ½¿² »¿­·´§ ¾» ¼±²» ¾§

·²­»®¬·²¹ ¬¸» ͧ­¬»³ °®± Ó ½±³°¿½¬r

¾«­¾¿®­ ·²¬± ¬¸» ®»¿® ¬»®³·²¿´ °¿®¬ ¿²¼

¬¸»² ¬¸» ·²½±³·²¹ ©·®»­ ·²¬± ¬¸» º®±²¬

°¿®¬ ±º ¬¸» ¬»®³·²¿´ò

Ô¿­»® °®·²¬·²¹

ß´´ °®·²¬·²¹­ ±º ¬¸» Í îðð ¿²¼ Í îðð Ó

ÓÝÞ­ô ´·µ» ¬¸» ¿°°®±ª¿´­ ±² ¬¸» ¼±³»

¿²¼ ¬¸» °®±¼«½¬ ·¼»²¬·º·½¿¬·±²ô ¿®» °®·²ó

¬»¼ ¾§ ¿ ´¿­»®ò ̸» ´¿­»® °®·²¬·²¹ »²­«®»­

¿ º®·½¬·±²ô ­½®¿¬½¸ ¿²¼ ­±´ª»²¬ ®»­·­¬¿²¬

³¿®µ·²¹ ±² ¬¸» ÓÝÞ­ò

Û¿­§ ·¼»²¬·º·½¿¬·±² ±º ¬¸» °®±¼«½¬­ ·²

½¿­» ±º ³¿·²¬»²¿²½» ±® ®»°´¿½»³»²¬­

¼«» ¬± ­¿º» ´¿­»® °®·²¬·²¹ò

Page 14: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

14 Line Protection Equipment 0115 ABB Low Voltage 15 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactQuick selection of MCBs for household and industrial application

Rated current Poles Solution

Up to 40A 1P+N SN201

Up to 20A 1P, 3P S200S

Up to 63A All poles S200

Up to 100A All poles S280

Up to 40A 1P, 3P SN201M

Up to 63A All poles S200M

Up to 63A All poles S200P

Up to 125A All poles S800C

Up to 125A All poles S800N

Up to 25A All poles S200P

Up to 125A All poles S800S

Up to 100A All poles S280S

Up to 40A 1P+N SN201, SN201M

Up to 63A All poles S200, S200M

Up to 40A All poles S200M

Up to 63A All poles S200P

Up to 63A 1P, 2P, 3P, 4P S200PR

Up to 25A All poles S200P

Up to 125A All poles S800C

Up to 45A All poles S500

Up to 125A All poles S800N

Up to 125A All poles S800S

Up to 125A All poles S800SCL+S800C

Up to 11A All poles S500

Up to 63A 1P, 2P, 3P, 4P S200MUC

Up to 125A All poles S800S-U C

Breaking cap. Icn at230-400V

6kA

10kA

15kA

20kA

25kA

6kA

10kA

15kA

25kA

30kA

36kA

50kA (with S800 and SCL)

10kA

50kA

Application

HOUSEHOLDOverload + short circuit

IEC/EN 60898-1

INDUSTRIALOverload + short circuit

IEC/EN 60947-2

INDUSTRIALDC applicationsIEC/EN 60947-2

START

Page 15: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

14 Line Protection Equipment 0115 ABB Low Voltage 15 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactQuick selection of MCBs for household and industrial application

3

System ProM CompactTechnical details - Tripping curves

1) The indicated tripping values of electromagnetic tripping devices apply to a frequency range of 16 2/3...60 Hz. In the case of diverging frequencies or direct current, see paragraph “Variation of tripping threshold of MCBs, according to network frequency” (page 6/7)

IEC-EN60898

Z ,K scitsiretcarahCD ,C ,B scitsiretcarahC

Tripping characteristics

esaeler lamrehT 2) Electromagnetic release 1)

Acc. to Tripping characteristic Current: Tripping time Currents: Tripping time pirt dloh lanoitnevnoc lanoitnevnoc tnerruc detar dna

ta tsael ta tnerruc .c gnippirt .c gnippirt-non segrus

IEC/EN 60898 B 6 to 63 A 1.13 · In > 1 h 3 · In > 0.1 sI · 54.1 n < 1 h 5 · In < 0.1 s

C 0.5 to 63 A 1.13 · In > 1 h 5 · In > 0.1 s I · 54.1 n < 1 h 10 · In < 0.1 s

D 0.5 to 63 A 1.13 · In > 1 h 10 · In > 0.1 sI · 54.1 n < 1 h 20 · In < 0.1 s

DIN VDE 0660/9.82 K 0.5 to 63 A 1.05 · In > 1 h I · 2.1 n < 1 h not applicable

IEC/EN 60947-2 1.05 · In > 2 h 10 · In > 0.2 sDIN VDE 0660 1.2 · In < 1 h 3) 14 · In < 0.2 s 8/69 1.5 · In < 2 min. 3) Part 101 6.0 · In > 2 s (T1)

DIN VDE 0660/9.82 Z 0.5 to 63 A 1.05 · In > 1 h I · 2.1 n < 1 h not applicable

IEC/EN 60947-2 1.05 · In > 2 h 2 · In > 0.2 sDIN VDE 0660 1.2 · In < 1 h 3) 3 · In < 0.2 s 8/69 1.5 · In < 2 min. 3) Part 101 6.0 · In > 2 s (T1)

2) The thermal releases are calibrated to a nominal reference ambient temperature; for Z and K, the value is 20 °C, for B and C = 30 °C. In the case of higher ambient temperatures, the current values fall by ca. 6 % for each 10 K temperature rise.

3) As from operating temperature (after I1 > 1 h or, as applicable, 2 h).

IEC-EN60947-2

ABB SF Section 3.5.indd 3/73 15/2/07 11:37:42 am

System ProM compactMCB tripping characteristics

Page 16: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

16 Line Protection Equipment 0115 ABB Low Voltage 17 Line Protection Equipment 0115 ABB Low Voltage

Series S200 Type B 6kA

Product Hierarchy 2400007

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code6 S201-B6 2CDS251001R0065 S202-B6 2CDS252001R0065 S203-B6 2CDS253001R0065 S204-B6 2CDS254001R0065

10 S201-B10 2CDS251001R0105 S202-B10 2CDS252001R0105 S203-B10 2CDS253001R0105 S204-B10 2CDS254001R0105

16 S201-B16 2CDS251001R1165 S202-B16 2CDS252001R0165 S203-B16 2CDS253001R0165 S204-B16 2CDS254001R0165

20 S201-B20 2CDS251001R0205 S202-B20 2CDS252001R0205 S203-B20 2CDS253001R0205 S204-B20 2CDS254001R0205

25 S201-B25 2CDS251001R0255 S202-B25 2CDS252001R0255 S203-B25 2CDS253001R0255 S204-B25 2CDS254001R0255

32 S201-B32 2CDS251001R0325 S202-B32 2CDS252001R0325 S203-B32 2CDS253001R0325 S204-B32 2CDS254001R0325

40 S201-B40 2CDS251001R0405 S202-B40 2CDS252001R0405 S203-B40 2CDS253001R0405 S204-B40 2CDS254001R0405

50 S201-B50 2CDS251001R0505 S202-B50 2CDS252001R0505 S203-B50 2CDS253001R0505 S204-B50 2CDS254001R0505

63 S201-B63 2CDS251001R0635 S202-B63 2CDS252001R0635 S203-B63 2CDS253001R0635 S204-B63 2CDS254001R0635

Series S200 Type C 6kA

Product Hierarchy 2400007

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code1 S201-C1 2CDS251001R0014 S202-C1 2CDS252001R0014 S203-C1 2CDS253001R0014 S204-C1 2CDS254001R0014

2 S201-C2 2CDS251001R0024 S202-C2 2CDS252001R0024 S203-C2 2CDS253001R0024 S204-C2 2CDS254001R0024

3 S201-C3 2CDS251001R0034 S202-C3 2CDS252001R0034 S203-C3 2CDS253001R0034 S204-C3 2CDS254001R0034

4 S201-C4 2CDS251001R0044 S202-C4 2CDS252001R0044 S203-C4 2CDS253001R0044 S204-C4 2CDS254001R0044

6 S201-C6 2CDS251001R0064 S202-C6 2CDS252001R0064 S203-C6 2CDS253001R0064 S204-C6 2CDS254001R0064

8 S201-C8 2CDS251001R0084 S202-C8 2CDS252001R0084 S203-C8 2CDS253001R0084 S204-C8 2CDS254001R0084

10 S201-C10 2CDS251001R0104 S202-C10 2CDS252001R0104 S203-C10 2CDS253001R0104 S204-C10 2CDS254001R0104

13 S201-C13 2CDS251001R0134 S202-C13 2CDS252001R0134 S203-C13 2CDS253001R0134 S204-C13 2CDS254001R0134

16 S201-C16 2CDS251001R0164 S202-C16 2CDS252001R0164 S203-C16 2CDS253001R0164 S204-C16 2CDS254001R0164

20 S201-C20 2CDS251001R0204 S202-C20 2CDS252001R0204 S203-C20 2CDS253001R0204 S204-C20 2CDS254001R0204

25 S201-C25 2CDS251001R0254 S202-C25 2CDS252001R0254 S203-C25 2CDS253001R0254 S204-C25 2CDS254001R0254

32 S201-C32 2CDS251001R0324 S202-C32 2CDS252001R0324 S203-C32 2CDS253001R0324 S204-C32 2CDS254001R0324

40 S201-C40 2CDS251001R0404 S202-C40 2CDS252001R0404 S203-C40 2CDS253001R0404 S204-C40 2CDS254001R0404

50 S201-C50 2CDS251001R0504 S202-C50 2CDS252001R0504 S203-C50 2CDS253001R0504 S204-C50 2CDS254001R0504

63 S201-C63 2CDS251001R0634 S202-C63 2CDS252001R0634 S203-C63 2CDS253001R0634 S204-C63 2CDS254001R0634

Series S200 Type D 6kA

Product Hierarchy 254004

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code1 S201-D1 2CDS251001R0011 S202-D1 2CDS252001R0011 S203-D1 2CDS253001R0011 S204-D1 2CDS254001R0011

2 S201-D2 2CDS251001R0021 S202-D2 2CDS252001R0021 S203-D2 2CDS253001R0021 S204-D2 2CDS254001R0021

3 S201-D3 2CDS251001R0031 S202-D3 2CDS252001R0031 S203-D3 2CDS253001R0031 S204-D3 2CDS254001R0031

4 S201-D4 2CDS251001R0041 S202-D4 2CDS252001R0041 S203-D4 2CDS253001R0041 S204-D4 2CDS254001R0041

6 S201-D6 2CDS251001R0061 S202-D6 2CDS252001R0061 S203-D6 2CDS253001R0061 S204-D6 2CDS254001R0061

8 S201-D8 2CDS251001R0081 S202-D8 2CDS252001R0081 S203-D8 2CDS253001R0081 S204-D8 2CDS254001R0081

10 S201-D10 2CDS251001R0101 S202-D10 2CDS252001R0101 S203-D10 2CDS253001R0101 S204-D10 2CDS254001R0101

13 S201-D13 2CDS251001R0131 S202-D13 2CDS252001R0131 S202-D13 2CDS253001R0131 S204-D13 2CDS254001R0131

16 S201-D16 2CDS251001R0161 S202-D16 2CDS252001R0161 S203-D16 2CDS253001R0161 S204-D16 2CDS254001R0161

20 S201-D20 2CDS251001R0201 S202-D20 2CDS252001R0201 S203-D20 2CDS253001R0201 S204-D20 2CDS254001R0201

25 S201-D25 2CDS251001R0251 S202-D25 2CDS252001R0251 S203-D25 2CDS253001R0251 S204-D25 2CDS254001R0251

32 S201-D32 2CDS251001R0321 S202-D32 2CDS252001R0321 S203-D32 2CDS253001R0321 S204-D32 2CDS254001R0321

40 S201-D40 2CDS251001R0401 S202-D40 2CDS252001R0401 S203-D40 2CDS253001R0401 S204-D40 2CDS254001R0401

50 S201-D50 2CDS251001R0501 S202-D50 2CDS252001R0501 S203-D50 2CDS253001R0501 S204-D50 2CDS254001R0501

63 S201-D63 2CDS251001R0631 S202-D63 2CDS252001R0631 S203-D63 2CDS253001R0631 S204-D63 2CDS254001R0631

System ProM compactS200 - B, C, D series

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

Page 17: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

16 Line Protection Equipment 0115 ABB Low Voltage 17 Line Protection Equipment 0115 ABB Low Voltage

Series S200 Type K 6kA

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code1 S201-K1 2CDS251001R0217 S202-K1 2CDS252001R0217 S203-K1 2CDS253001R0217 S204-K1 2CDS254001R0217

2 S201-K2 2CDS251001R0277 S202-K2 2CDS252001R0277 S203-K2 2CDS253001R0277 S204-K2 2CDS254001R0277

3 S201-K3 2CDS251001R0317 S202-K3 2CDS252001R0317 S203-K3 2CDS253001R0317 S204-K3 2CDS254001R0317

4 S201-K4 2CDS251001R0337 S202-K4 2CDS252001R0337 S203-K4 2CDS253001R0337 S204-K4 2CDS254001R0337

6 S201-K6 2CDS251001R0377 S202-K6 2CDS252001R0377 S203-K6 2CDS253001R0377 S204-K6 2CDS254001R0377

8 S201-K8 2CDS251001R0407 S202-K8 2CDS252001R0407 S203-K8 2CDS253001R0407 S204-K8 2CDS254001R0407

10 S201-K10 2CDS251001R0427 S202-K10 2CDS252001R0427 S203-K10 2CDS253001R0427 S204-K10 2CDS254001R0427

13 S201-K13 2CDS251001R0447 S202-K13 2CDS252001R0447 S202-K13 2CDS253001R0447 S204-K13 2CDS254001R0447

16 S201-K16 2CDS251001R0467 S202-K16 2CDS252001R0467 S203-K16 2CDS253001R0467 S204-K16 2CDS254001R0467

20 S201-K20 2CDS251001R0487 S202-K20 2CDS252001R0487 S203-K20 2CDS253001R0487 S204-K20 2CDS254001R0487

25 S201-K25 2CDS251001R0517 S202-K25 2CDS252001R0517 S203-K25 2CDS253001R0517 S204-K25 2CDS254001R0517

32 S201-K32 2CDS251001R0537 S202-K32 2CDS252001R0537 S203-K32 2CDS253001R0537 S204-K32 2CDS254001R0537

40 S201-K40 2CDS251001R0557 S202-K40 2CDS252001R0557 S203-K40 2CDS253001R0557 S204-K40 2CDS254001R0557

50 S201-K50 2CDS251001R0577 S202-K50 2CDS252001R0577 S203-K50 2CDS253001R0577 S204-K50 2CDS254001R0577

63 S201-K63 2CDS251001R0607 S202-K63 2CDS252001R0607 S203-K63 2CDS253001R0607 S204-K63 2CDS254001R0607

Series S200 Type Z 6kA

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code1 S201-Z1 2CDS251001R0218 S202-Z1 2CDS252001R0218 S203-Z1 2CDS253001R0218 S204-Z1 2CDS254001R0218

2 S201-Z2 2CDS251001R0278 S202-Z2 2CDS252001R0278 S203-Z2 2CDS253001R0278 S204-Z2 2CDS254001R0278

3 S201-Z3 2CDS251001R0318 S202-Z3 2CDS252001R0318 S203-Z3 2CDS253001R0318 S204-Z3 2CDS254001R0318

4 S201-Z4 2CDS251001R0338 S202-Z4 2CDS252001R0338 S203-Z4 2CDS253001R0338 S204-Z4 2CDS254001R0338

6 S201-Z6 2CDS251001R0378 S202-Z6 2CDS252001R0378 S203-Z6 2CDS253001R0378 S204-Z6 2CDS254001R0378

8 S201-Z8 2CDS251001R0408 S202-Z8 2CDS252001R0408 S203-Z8 2CDS253001R0408 S204-Z8 2CDS254001R0408

10 S201-Z10 2CDS251001R0428 S202-Z10 2CDS252001R0428 S203-Z10 2CDS253001R0428 S204-Z10 2CDS254001R0428

13 S201-Z13 2CDS251001R0448 S202-Z13 2CDS252001R0448 S202K13 2CDS253001R0448 S204-Z13 2CDS254001R0448

16 S201-Z16 2CDS251001R0468 S202-Z16 2CDS252001R0468 S203-Z16 2CDS253001R0468 S204-Z16 2CDS254001R0468

20 S201-Z20 2CDS251001R0488 S202-Z20 2CDS252001R0488 S203-Z20 2CDS253001R0488 S204-Z20 2CDS254001R0468

25 S201-Z25 2CDS251001R0518 S202-Z25 2CDS252001R0518 S203-Z25 2CDS253001R0518 S204-Z25 2CDS254001R0518

32 S201-Z32 2CDS251001R0538 S202-Z32 2CDS252001R0538 S203-Z32 2CDS253001R0538 S204-Z32 2CDS254001R0538

40 S201-Z40 2CDS251001R0558 S202-Z40 2CDS252001R0558 S203-Z40 2CDS253001R0558 S204-Z40 2CDS254001R0558

50 S201-Z50 2CDS251001R0578 S202-Z50 2CDS252001R0578 S203-Z50 2CDS253001R0578 S204-Z50 2CDS254001R0578

63 S201-Z63 2CDS251001R0608 S202-Z63 2CDS252001R0608 S203-Z63 2CDS253001R0608 S204-Z63 2CDS254001R0608

System ProM compactS200 - K, Z, B series

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

Page 18: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

18 Line Protection Equipment 0115 ABB Low Voltage 19 Line Protection Equipment 0115 ABB Low Voltage

Series S200M Type B 10kA

Product Hierarchy 2400004

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

6 S201M-B6 2CDS271001R0065 S202M-B6 2CDS272001R0065 S203M-B6 2CDS273001R0065 S204M-B6 2CDS274001R0065

10 S201M-B10 2CDS271001R0105 S202M-B10 2CDS272001R0105 S203M-B10 2CDS273001R0105 S204M-B10 2CDS274001R0105

16 S201M-B16 2CDS271001R0165 S202M-B16 2CDS272001R0165 S203M-B16 2CDS273001R0165 S204M-B16 2CDS274001R0165

20 S201M-B20 2CDS271001R0205 S202M-B20 2CDS272001R0205 S203M-B20 2CDS273001R0205 S204M-B20 2CDS274001R0205

25 S201M-B25 2CDS271001R0255 S202M-B25 2CDS272001R0255 S203M-B25 2CDS273001R0255 S204M-B25 2CDS274001R0255

32 S201M-B32 2CDS271001R0325 S202M-B32 2CDS272001R0325 S203M-B32 2CDS273001R0325 S204M-B32 2CDS274001R0325

40 S201M-B40 2CDS271001R0405 S202M-B40 2CDS272001R0405 S203M-B40 2CDS273001R0405 S204M-B40 2CDS274001R0405

50 S201M-B50 2CDS271001R0505 S202M-B50 2CDS272001R0505 S203M-B50 2CDS273001R0505 S204M-B50 2CDS274001R0505

63 S201M-B63 2CDS271001R0635 S202M-B63 2CDS272001R0635 S203M-B63 2CDS273001R0635 S204M-B63 2CDS274001R0635

Series S200M Type C 10kA

Product Hierarchy 2400004Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code1 S201M-C1 2CDS271001R0014 S202M-C1 2CDS272001R0014 S203M-C1 2CDS273001R0014 S204M-C1 2CDS274001R0014

2 S201M-C2 2CDS271001R0024 S202M-C2 2CDS272001R0024 S203M-C2 2CDS273001R0024 S204M-C2 2CDS274001R0024

3 S201M-C3 2CDS271001R0034 S202M-C3 2CDS272001R0034 S203M-C3 2CDS273001R0034 S204M-C3 2CDS274001R0034

4 S201M-C4 2CDS271001R0044 S202M-C4 2CDS272001R0044 S203M-C4 2CDS273001R0044 S204M-C4 2CDS274001R0044

6 S201M-C6 2CDS271001R0064 S202M-C6 2CDS272001R0064 S203M-C6 2CDS273001R0064 S204M-C6 2CDS274001R0064

8 S201M-C8 2CDS271001R0084 S202M-C8 2CDS272001R0084 S203M-C8 2CDS273001R0084 S204M-C8 2CDS274001R0084

10 S201M-C10 2CDS271001R0104 S202M-C10 2CDS272001R0104 S203M-C10 2CDS273001R0104 S204M-C10 2CDS274001R0104

13 S201M-C13 2CDS271001R0134 S202M-C13 2CDS272001R0134 S203M-C13 2CDS273001R0134 S204M-C13 2CDS274001R0134

16 S201M-C16 2CDS271001R0164 S202M-C16 2CDS272001R0164 S203M-C16 2CDS273001R0164 S204M-C16 2CDS274001R0164

20 S201M-C20 2CDS271001R0204 S202M-C20 2CDS272001R0204 S203M-C20 2CDS273001R0204 S204M-C20 2CDS274001R0204

25 S201M-C25 2CDS271001R0254 S202M-C25 2CDS272001R0254 S203M-C25 2CDS273001R0254 S204M-C25 2CDS274001R0254

32 S201M-C32 2CDS271001R0324 S202M-C32 2CDS272001R0324 S203M-C32 2CDS273001R0324 S204M-C32 2CDS274001R0324

40 S201M-C40 2CDS271001R0404 S202M-C40 2CDS272001R0404 S203M-C40 2CDS273001R0404 S204M-C40 2CDS274001R0404

50 S201M-C50 2CDS271001R0504 S202M-C50 2CDS272001R0504 S203M-C50 2CDS273001R0504 S204M-C50 2CDS274001R0504

63 S201M-C63 2CDS271001R0634 S202M-C63 2CDS272001R0634 S203M-C63 2CDS273001R0634 S204M-C63 2CDS274001R0634

Series S200M Type D 10kA

Product Hierarchy 2400004

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code1 S201M-D1 2CDS271001R0011 S202M-D1 2CDS272001R0011 S203M-D1 2CDS273001R0011 S204M-D1 2CDS274001R0011

2 S201M-D2 2CDS271001R0021 S202M-D2 2CDS272001R0021 S203M-D2 2CDS273001R0021 S204M-D2 2CDS274001R0021

3 S201M-D3 2CDS271001R0031 S202M-D3 2CDS272001R0031 S203M-D3 2CDS273001R0031 S204M-D3 2CDS274001R0031

4 S201M-D4 2CDS271001R0041 S202M-D4 2CDS272001R0041 S203M-D4 2CDS273001R0041 S204M-D4 2CDS274001R0041

6 S201M-D6 2CDS271001R0061 S202M-D6 2CDS272001R0061 S203M-D6 2CDS273001R0061 S204M-D6 2CDS274001R0061

8 S201M-D8 2CDS271001R0081 S202M-D8 2CDS272001R0081 S203M-D8 2CDS273001R0081 S204M-D8 2CDS274001R0081

10 S201M-D10 2CDS271001R0101 S202M-D10 2CDS272001R0101 S203M-D10 2CDS273001R0101 S204M-D10 2CDS274001R0101

13 S201M-D13 2CDS271001R0131 S202M-D13 2CDS272001R0131 S202M-D13 2CDS273001R0131 S204M-D13 2CDS274001R0131

16 S201M-D16 2CDS271001R0161 S202M-D16 2CDS272001R0161 S203M-D16 2CDS273001R0161 S204M-D16 2CDS274001R0161

20 S201M-D20 2CDS271001R0201 S202M-D20 2CDS272001R0201 S203M-D20 2CDS273001R0201 S204M-D20 2CDS274001R0201

25 S201M-D25 2CDS271001R0251 S202M-D25 2CDS272001R0251 S203M-D25 2CDS273001R0251 S204M-D25 2CDS274001R0251

32 S201M-D32 2CDS271001R0321 S202M-D32 2CDS272001R0321 S203M-D32 2CDS273001R0321 S204M-D32 2CDS274001R0321

40 S201M-D40 2CDS271001R0401 S202M-D40 2CDS272001R0401 S203M-D40 2CDS273001R0401 S204M-D40 2CDS274001R0401

50 S201M-D50 2CDS271001R0501 S202M-D50 2CDS272001R0501 S203M-D50 2CDS273001R0501 S204M-D50 2CDS274001R0501

63 S201M-D63 2CDS271001R0631 S202M-D63 2CDS272001R0631 S203M-D63 2CDS273001R0631 S204M-D63 2CDS274001R0631

System ProM compactS200M - C, D, K series

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

Page 19: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

18 Line Protection Equipment 0115 ABB Low Voltage 19 Line Protection Equipment 0115 ABB Low Voltage

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

Series S200M Type Z 10kA

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

0.5 S201M-Z0.5 2CDS271001R0158 S202M-Z0.5 2CDS272001R0158 S203M-Z0.5 2CDS273001R0158 S204M-Z0.5 2CDS274001R0158

1 S201M-Z1 2CDS271001R0218 S202M-Z1 2CDS272001R0218 S203M-Z1 2CDS273001R0218 S204M-Z1 2CDS274001R0218

2 S201M-Z2 2CDS271001R0278 S202M-Z2 2CDS272001R0278 S203M-Z2 2CDS273001R0278 S204M-Z2 2CDS274001R0278

3 S201M-Z3 2CDS271001R0318 S202M-Z3 2CDS272001R0318 S203M-Z3 2CDS273001R0318 S204M-Z3 2CDS274001R0318

4 S201M-Z4 2CDS271001R0338 S202M-Z4 2CDS272001R0338 S203M-Z4 2CDS273001R0338 S204M-Z4 2CDS274001R0338

6 S201M-Z6 2CDS271001R0378 S202M-Z6 2CDS272001R0378 S203M-Z6 2CDS273001R0378 S204M-Z6 2CDS274001R0378

8 S201M-Z8 2CDS271001R0408 S202M-Z8 2CDS272001R0408 S203M-Z8 2CDS273001R0408 S204M-Z8 2CDS274001R0408

10 S201M-Z10 2CDS271001R0428 S202M-Z10 2CDS272001R0428 S203M-Z10 2CDS273001R0428 S204M-Z10 2CDS274001R0428

16 S201M-Z16 2CDS271001R0468 S202M-Z16 2CDS272001R0468 S203M-Z16 2CDS273001R0468 S204M-Z16 2CDS274001R0468

20 S201M-Z20 2CDS271001R0488 S202M-Z20 2CDS272001R0488 S203M-Z20 2CDS273001R0488 S204M-Z20 2CDS274001R0488

25 S201M-Z25 2CDS271001R0518 S202M-Z25 2CDS272001R0518 S203M-Z25 2CDS273001R0518 S204M-Z25 2CDS274001R0518

32 S201M-Z32 2CDS271001R0538 S202M-Z32 2CDS272001R0538 S203M-Z32 2CDS273001R0538 S204M-Z32 2CDS274001R0538

40 S201M-Z40 2CDS271001R0558 S202M-Z40 2CDS272001R0558 S203M-Z40 2CDS273001R0558 S204M-Z40 2CDS274001R0558

50 S201M-Z50 2CDS271001R0578 S202M-Z50 2CDS272001R0578 S203M-Z50 2CDS273001R0578 S204M-Z50 2CDS274001R0578

63 S201M-Z63 2CDS271001R0608 S202M-Z63 2CDS272001R0608 S203M-Z63 2CDS273001R0608 S204M-Z63 2CDS274001R0608

Series S200M Type K 10kA

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

1 S201M-K1 2CDS271001R0217 S202M-K1 2CDS272001R0217 S203M-K1 2CDS273001R0217 S204M-K1 2CDS274001R0217

2 S201M-K2 2CDS271001R0277 S202M-K2 2CDS272001R0277 S203M-K2 2CDS273001R0277 S204M-K2 2CDS274001R0277

3 S201M-K3 2CDS271001R0317 S202M-K3 2CDS272001R0317 S203M-K3 2CDS273001R0317 S204M-K3 2CDS274001R0317

4 S201M-K4 2CDS271001R0337 S202M-K4 2CDS272001R0337 S203M-K4 2CDS273001R0337 S204M-K4 2CDS274001R0337

6 S201M-K6 2CDS271001R0377 S202M-K6 2CDS272001R0377 S203M-K6 2CDS273001R0377 S204M-K6 2CDS274001R0377

8 S201M-K8 2CDS271001R0407 S202M-K8 2CDS272001R0407 S203M-K8 2CDS273001R0407 S204M-K8 2CDS274001R0407

10 S201M-K10 2CDS271001R0427 S202M-K10 2CDS272001R0427 S203M-K10 2CDS273001R0427 S204M-K10 2CDS274001R0427

13 S201M-K13 2CDS271001R0447 S202M-K13 2CDS272001R0447 S203M-K13 2CDS273001R0447 S204M-K13 2CDS274001R0447

16 S201M-K16 2CDS271001R0467 S202M-K16 2CDS272001R0467 S203M-K16 2CDS273001R0467 S204M-K16 2CDS274001R0467

20 S201M-K20 2CDS271001R0487 S202M-K20 2CDS272001R0487 S203M-K20 2CDS273001R0487 S204M-K20 2CDS274001R0487

25 S201M-K25 2CDS271001R0517 S202M-K25 2CDS272001R0517 S203M-K25 2CDS273001R0517 S204M-K25 2CDS274001R0517

32 S201M-K32 2CDS271001R0537 S202M-K32 2CDS272001R0537 S203M-K32 2CDS273001R0537 S204M-K32 2CDS274001R0537

40 S201M-K40 2CDS271001R0557 S202M-K40 2CDS272001R0557 S203M-K40 2CDS273001R0557 S204M-K40 2CDS274001R0557

50 S201M-K50 2CDS271001R0577 S202M-K50 2CDS272001R0577 S203M-K50 2CDS273001R0577 S204M-K50 2CDS274001R0577

63 S201M-K63 2CDS271001R0607 S202M-K63 2CDS272001R0607 S203M-K63 2CDS273001R0607 S204M-K63 2CDS274001R0607

System ProM compactS200M - Z, K series

Page 20: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

20 Line Protection Equipment 0115 ABB Low Voltage 21 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactS200P - B, C, D series

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

Series S200P Type B

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

6 S201P-B6 25kA 2CDS281001R0065 S202P-B6 25kA 2CDS282001R0065 S203P-B6 25kA 2CDS283001R0065 S204P-B6 25kA 2CDS284001R0065

10 S201P-B10 25kA 2CDS281001R0105 S202P-B8 25kA 2CDS282001R0105 S203P-B8 25kA 2CDS283001R0105 S204P-B8 25kA 2CDS284001R0105

13 S201P-B13 25kA 2CDS281001R0135 S202P-B13 25kA 2CDS282001R0135 S203P-B13 25kA 2CDS283001R0135 S204P-B13 25kA 2CDS284001R0135

16 S201P-B10 25kA 2CDS281001R0165 S202P-B16 25kA 2CDS282001R0165 S203P-B16 25kA 2CDS283001R0165 S204P-B16 25kA 2CDS284001R0165

20 S201P-B20 25kA 2CDS281001R0205 S202P-B20 25kA 2CDS282001R0205 S203P-B20 25kA 2CDS283001R0205 S204P-B20 25kA 2CDS284001R0205

25 S201P-B25 25kA 2CDS281001R0255 S202P-B25 25kA 2CDS282001R0255 S203P-B25 25kA 2CDS283001R0255 S204P-B25 25kA 2CDS284001R0255

32 S201P-B32 15kA 2CDS281001R0325 S202P-B32 15kA 2CDS282001R0325 S203P-B32 15kA 2CDS283001R0325 S204P-B32 15kA 2CDS284001R0325

40 S201P-B40 15kA 2CDS281001R0405 S202P-B40 15kA 2CDS282001R0405 S203P-B40 15kA 2CDS283001R0405 S204P-B40 15kA 2CDS284001R0405

50 S201P-B50 15kA 2CDS281001R0505 S202P-B50 15kA 2CDS282001R0505 S203P-B50 15kA 2CDS283001R0505 S204P-B50 15kA 2CDS284001R0505

63 S201P-B63 15kA 2CDS281001R0635 S202P-B63 15kA 2CDS282001R0635 S203P-B63 15kA 2CDS283001R0635 S204P-B63 15kA 2CDS284001R0635

Series S200P Type C

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code0.5 S201P-C0.5 25kA 2CDS281001R0984 S202P-C0.5 25kA 2CDS282001R0984 S203P-C0.5 25kA 2CDS283001R0984 S204P-C0.5 25kA 2CDS284001R0984

1 S201P-C1 25kA 2CDS281001R0014 S202P-C1 25kA 2CDS282001R0014 S203P-C1 25kA 2CDS283001R0014 S204P-C1 25kA 2CDS284001R0014

1.6 S201P-C1.6 25kA 2CDS281001R0974 S202P-C1.6 25kA 2CDS282001R0974 S203P-C1.6 25kA 2CDS283001R0974 S204P-C1.6 25kA 2CDS284001R0974

2 S201P-C2 25kA 2CDS281001R0024 S202P-C2 25kA 2CDS282001R0024 S203P-C2 25kA 2CDS283001R0024 S204P-C2 25kA 2CDS284001R0024

3 S201P-C3 25kA 2CDS281001R0034 S202P-C3 25kA 2CDS282001R0034 S203P-C3 25kA 2CDS283001R0034 S204P-C3 25kA 2CDS284001R0034

4 S201P-C6 25kA 2CDS281001R0044 S202P-C4 25kA 2CDS282001R0044 S203P-C4 25kA 2CDS283001R0044 S204P-C4 25kA 2CDS284001R0044

6 S201P-C6 25kA 2CDS281001R0064 S202P-C6 25kA 2CDS282001R0064 S203P-C6 25kA 2CDS283001R0064 S204P-C6 25kA 2CDS284001R0064

8 S201P-C6 25kA 2CDS281001R0084 S202P-C8 25kA 2CDS282001R0084 S203P-C8 25kA 2CDS283001R0084 S204P-C8 25kA 2CDS284001R0084

10 S201P-C10 25kA 2CDS281001R0104 S202P-C10 25kA 2CDS282001R0104 S203P-C10 25kA 2CDS283001R0104 S204P-C10 25kA 2CDS284001R0104

16 S201P-C16 25kA 2CDS281001R0164 S202P-C16 25kA 2CDS282001R0164 S203P-C16 25kA 2CDS283001R0164 S204P-C16 25kA 2CDS284001R0164

20 S201P-C20 25kA 2CDS281001R0204 S202P-C20 25kA 2CDS282001R0204 S203P-C20 25kA 2CDS283001R0204 S204P-C20 25kA 2CDS284001R0204

25 S201P-C25 25kA 2CDS281001R0254 S202P-C25 25kA 2CDS282001R0254 S203P-C25 25kA 2CDS283001R0254 S204P-C25 25kA 2CDS284001R0254

32 S201P-C32 15kA 2CDS281001R0324 S202P-C32 15kA 2CDS282001R0324 S203P-C32 15kA 2CDS283001R0324 S204P-C32 15kA 2CDS284001R0324

40 S201P-C40 15kA 2CDS281001R0404 S202P-C40 15kA 2CDS282001R0404 S203P-C40 15kA 2CDS283001R0404 S204P-C40 15kA 2CDS284001R0404

50 S201P-C50 15kA 2CDS281001R0504 S202P-C50 15kA 2CDS282001R0504 S203P-C50 15kA 2CDS283001R0504 S204P-C50 15kA 2CDS284001R0504

63 S201P-C63 15kA 2CDS281001R0634 S202P-C63 15kA 2CDS282001R0634 S203P-C63 15kA 2CDS283001R0634 S204P-C63 15kA 2CDS284001R0634

Series S200P Type D

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code0.5 S201P-D0.5 25kA 2CDS281001R0981 S202P-D0.5 25kA 2CDS282001R0981 S203P-D0.5 25kA 2CDS283001R0981 S204P-D0.5 25kA 2CDS284001R0981

1 S201P-D1 25kA 2CDS281001R0011 S202P-D1 25kA 2CDS282001R0011 S203P-D1 25kA 2CDS283001R0011 S204P-D1 25kA 2CDS284001R0011

1.6 S201P-D1.6 25kA 2CDS281001R0971 S202P-D1.6 25kA 2CDS282001R0971 S203P-D1.6 25kA 2CDS283001R0971 S204P-D1.6 25kA 2CDS284001R0971

2 S201P-D2 25kA 2CDS281001R0021 S202P-D2 25kA 2CDS282001R0021 S203P-D2 25kA 2CDS283001R0021 S204P-D2 25kA 2CDS284001R0021

3 S201P-D3 25kA 2CDS281001R0031 S202P-D3 25kA 2CDS282001R0031 S203P-D3 25kA 2CDS283001R0031 S204P-D3 25kA 2CDS284001R0031

4 S201P-D6 25kA 2CDS281001R0041 S202P-D4 25kA 2CDS282001R0041 S203P-D4 25kA 2CDS283001R0041 S204P-D4 25kA 2CDS284001R0041

6 S201P-D6 25kA 2CDS281001R0061 S202P-D6 25kA 2CDS282001R0061 S203P-D6 25kA 2CDS283001R0061 S204P-D6 25kA 2CDS284001R0061

8 S201P-D6 25kA 2CDS281001R0081 S202P-D8 25kA 2CDS282001R0081 S203P-D8 25kA 2CDS283001R0081 S204P-D8 25kA 2CDS284001R0081

10 S201P-D10 25kA 2CDS281001R0101 S202P-D10 25kA 2CDS282001R0101 S203P-D10 25kA 2CDS283001R0101 S204P-D10 25kA 2CDS284001R0101

13 S201P-D13 25kA 2CDS281001R0131 S202P-D13 25kA 2CDS282001R0131 S203P-D13 25kA 2CDS283001R0131 S204P-D13 25kA 2CDS284001R0131

16 S201P-D16 25kA 2CDS281001R0161 S202P-D16 25kA 2CDS282001R0161 S203P-D16 25kA 2CDS283001R0161 S204P-D16 25kA 2CDS284001R0161

20 S201P-D20 25kA 2CDS281001R0201 S202P-D20 25kA 2CDS282001R0201 S203P-D20 25kA 2CDS283001R0201 S204P-D20 25kA 2CDS284001R0201

25 S201P-D25 25kA 2CDS281001R0251 S202P-D25 25kA 2CDS282001R0251 S203P-D25 25kA 2CDS283001R0251 S204P-D25 25kA 2CDS284001R0251

32 S201P-D32 15kA 2CDS281001R0321 S202P-D32 15kA 2CDS282001R0321 S203P-D32 15kA 2CDS283001R0321 S204P-D32 15kA 2CDS284001R0321

40 S201P-D40 15kA 2CDS281001R0401 S202P-D40 15kA 2CDS282001R0401 S203P-D40 15kA 2CDS283001R0401 S204P-D40 15kA 2CDS284001R0401

50 S201P-D50 15kA 2CDS281001R0501 S202P-D50 15kA 2CDS282001R0501 S203P-D50 15kA 2CDS283001R0501 S204P-D50 15kA 2CDS284001R0501

63 S201P-D63 15kA 2CDS281001R0631 S202P-D63 15kA 2CDS282001R0631 S203P-D63 15kA 2CDS283001R0631 S204P-D63 15kA 2CDS284001R0631

Page 21: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

20 Line Protection Equipment 0115 ABB Low Voltage 21 Line Protection Equipment 0115 ABB Low Voltage

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

3/4

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

B

System ProM CompactMCB’s S200 series M-B characteristic - 10kA

2CS

C40

0413

F020

12C

SC

4004

11F0

201

2CS

C40

0415

F020

12C

SC

4004

43F0

201

S 200 M-B characteristicFunction: protection and control of circuits against overloads and short-circuits; protection for people & big length cables in TN & IT systems

Applications: residential, commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2Icn=10 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

6 S 201 M-B 6 8.84 S 202 M-B 6 25.36 S 203 M-B 6 37.67 S 204 M-B 6 61.89

10 S 201 M-B 10 8.10 S 202 M-B 10 23.30 S 203 M-B 10 35.32 S 204 M-B 10 58.06

13 S 201 M-B 13 8.10 S 202 M-B 13 23.30 S 203 M-B 13 35.32 S 204 M-B 13 58.06

16 S 201 M-B 16 8.10 S 202 M-B 16 23.30 S 203 M-B 16 35.32 S 204 M-B 16 58.06

20 S 201 M-B 20 8.10 S 202 M-B 20 23.30 S 203 M-B 20 35.32 S 204 M-B 20 58.06

25 S 201 M-B 25 8.10 S 202 M-B 25 23.30 S 203 M-B 25 35.32 S 204 M-B 25 58.06

32 S 201 M-B 32 8.10 S 202 M-B 32 23.30 S 203 M-B 32 35.32 S 204 M-B 32 58.06

40 S 201 M-B 40 8.84 S 202 M-B 40 25.43 S 203 M-B 40 37.67 S 204 M-B 40 61.88

50 S 201 M-B 50 9.28 S 202 M-B 50 26.64 S 203 M-B 50 39.55 S 204 M-B 50 64.97

63 S 201 M-B 63 9.40 S 202 M-B 63 26.87 S 203 M-B 63 39.93 S 204 M-B 63 72.58

ABB SF Section 3.5.indd 3/4 15/2/07 11:34:35 am

Series S200P Type K

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

0.2 S201P-K0.2 25kA 2CDS281001R0087 S202P-K0.2 25kA 2CDS282001R0087 S203P-K0.2 25kA 2CDS283001R0087 S204P-K0.2 25kA 2CDS284001R0087

0.3 S201P-K0.3 25kA 2CDS281001R0117 S202P-K0.3 25kA 2CDS282001R0117 S203P-K0.3 25kA 2CDS283001R0117 S204P-K0.3 25kA 2CDS284001R0117

0.5 S201P-K0.5 25kA 2CDS281001R0157 S202P-K0.5 25kA 2CDS282001R0157 S203P-K0.5 25kA 2CDS283001R0157 S204P-K0.5 25kA 2CDS284001R0157

0.75 S201P-K0.75 25kA 2CDS281001R0187 S202P-K0.75 25kA 2CDS282001R0187 S203P-K0.75 25kA 2CDS283001R0187 S204P-K0.75 25kA 2CDS284001R0187

1 S201P-K1 25kA 2CDS281001R0217 S202P-K1 25kA 2CDS282001R0217 S203P-K1 25kA 2CDS283001R0217 S204P-K1 25kA 2CDS284001R0217

2 S201P-K2 25kA 2CDS281001R0277 S202P-K2 25kA 2CDS282001R0277 S203P-K2 25kA 2CDS283001R0277 S204P-K2 25kA 2CDS284001R0277

3 S201P-K3 25kA 2CDS281001R0317 S202P-K3 25kA 2CDS282001R0317 S203P-K3 25kA 2CDS283001R0317 S204P-K3 25kA 2CDS284001R0317

4 S201P-K4 25kA 2CDS281001R0337 S202P-K4 25kA 2CDS282001R0337 S203P-K4 25kA 2CDS283001R0337 S204P-K4 25kA 2CDS284001R0337

6 S201P-K6 25kA 2CDS281001R0377 S202P-K6 25kA 2CDS282001R0377 S203P-K6 25kA 2CDS283001R0377 S204P-K6 25kA 2CDS284001R0377

8 S201P-K8 25kA 2CDS281001R0407 S202P-K8 25kA 2CDS282001R0407 S203P-K8 25kA 2CDS283001R0407 S204P-K8 25kA 2CDS284001R0407

13 S201P-K13 25kA 2CDS281001R0427 S202P-K13 25kA 2CDS282001R0427 S203P-K13 25kA 2CDS283001R0427 S204P-K13 25kA 2CDS284001R0427

16 S201P-K10 25kA 2CDS281001R0447 S202P-K10 25kA 2CDS282001R0447 S203P-K10 25kA 2CDS283001R0447 S204P-K10 25kA 2CDS284001R0447

20 S201P-K20 25kA 2CDS281001R0487 S202P-K20 25kA 2CDS282001R0487 S203P-K20 25kA 2CDS283001R0487 S204P-K20 25kA 2CDS284001R0487

25 S201P-K25 25kA 2CDS281001R0517 S202P-K25 25kA 2CDS282001R0517 S203P-K25 25kA 2CDS283001R0517 S204P-K25 25kA 2CDS284001R0517

32 S201P-K32 15kA 2CDS281001R0537 S202P-K32 15kA 2CDS282001R0537 S203P-K32 15kA 2CDS283001R0537 S204P-K32 15kA 2CDS284001R0537

40 S201P-K40 15kA 2CDS281001R0557 S202P-K40 15kA 2CDS282001R0557 S203P-K40 15kA 2CDS283001R0557 S204P-K40 15kA 2CDS284001R0557

50 S201P-K50 15kA 2CDS281001R0577 S202P-K50 15kA 2CDS282001R0577 S203P-K50 15kA 2CDS283001R0577 S204P-K50 15kA 2CDS284001R0577

63 S201P-K63 15kA 2CDS281001R0607 S202P-K63 15kA 2CDS282001R0607 S203P-K63 15kA 2CDS283001R0607 S204P-K63 15kA 2CDS284001R0607

Series S200P Type Z

Product Hierarchy 2400002

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code0.5 S201P-Z0.5 25kA 2CDS281001R0158 S202P-Z0.5 25kA 2CDS282001R0158 S203P-Z0.5 25kA 2CDS283001R0158 S204P-Z0.5 25kA 2CDS284001R0158

1 S201P-Z1 25kA 2CDS281001R0218 S202P-Z1 25kA 2CDS282001R0218 S203P-Z1 25kA 2CDS283001R0218 S204P-Z1 25kA 2CDS284001R0218

1.6 S201P-Z1.6 25kA 2CDS281001R0258 S202P-Z1.6 25kA 2CDS282001R0258 S203P-Z1.6 25kA 2CDS283001R0258 S204P-Z1.6 25kA 2CDS284001R0258

2 S201P-Z2 25kA 2CDS281001R0278 S202P-Z2 25kA 2CDS282001R0278 S203P-Z2 25kA 2CDS283001R0278 S204P-Z2 25kA 2CDS284001R0278

3 S201P-Z3 25kA 2CDS281001R0318 S202P-Z3 25kA 2CDS282001R0318 S203P-Z3 25kA 2CDS283001R0318 S204P-Z3 25kA 2CDS284001R0318

6 S201P-Z6 25kA 2CDS281001R0378 S202P-Z6 25kA 2CDS282001R0378 S203P-Z6 25kA 2CDS283001R0378 S204P-Z6 25kA 2CDS284001R0378

8 S201P-Z8 25kA 2CDS281001R0408 S202P-Z8 25kA 2CDS282001R0408 S203P-Z8 25kA 2CDS283001R0408 S204P-Z8 25kA 2CDS284001R0408

10 S201P-Z10 25kA 2CDS281001R0428 S202P-Z10 25kA 2CDS282001R0428 S203P-Z10 25kA 2CDS283001R0428 S204P-Z10 25kA 2CDS284001R0428

16 S201P-Z16 25kA 2CDS281001R0468 S202P-Z16 25kA 2CDS282001R0468 S203P-Z16 25kA 2CDS283001R0468 S204P-Z16 25kA 2CDS284001R0468

20 S201P-Z20 25kA 2CDS281001R0488 S202P-Z20 25kA 2CDS282001R0488 S203P-Z20 25kA 2CDS283001R0488 S204P-Z20 25kA 2CDS284001R0488

25 S201P-Z25 25kA 2CDS281001R0518 S202P-Z25 25kA 2CDS282001R0518 S203P-Z25 25kA 2CDS283001R0518 S204P-Z25 25kA 2CDS284001R0518

32 S201P-Z32 15kA 2CDS281001R0538 S202P-Z32 15kA 2CDS282001R0538 S203P-Z32 15kA 2CDS283001R0538 S204P-Z32 15kA 2CDS284001R0538

40 S201P-Z40 15kA 2CDS281001R0558 S202P-Z40 15kA 2CDS282001R0558 S203P-Z40 15kA 2CDS283001R0558 S204P-Z40 15kA 2CDS284001R0558

50 S201P-Z50 15kA 2CDS281001R0578 S202P-Z50 15kA 2CDS282001R0578 S203P-Z50 15kA 2CDS283001R0578 S204P-Z50 15kA 2CDS284001R0578

63 S201P-Z63 15kA 2CDS281001R0608 S202P-Z63 15kA 2CDS282001R0608 S203P-Z63 15kA 2CDS283001R0608 S204P-Z63 15kA 2CDS284001R0608

System ProM compactS200M-P - K, Z series

Page 22: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

22 Line Protection Equipment 0115 ABB Low Voltage 23 Line Protection Equipment 0115 ABB Low Voltage

System ProM compact SN201 - single pole & switched neutral

Series SN201 6kA

Product Hierarchy 2400004

Type B Type C Type DSingle Pole + Switched Neutral Single Pole + Switched Neutral Single Pole + Switched Neutral

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code

2 - - SN201-C2 2CSS255101R0024 - -

4 - - SN201-C4 2CSS255101R0044 - -

6 SN201-B6 2CSS255101R0065 SN201-C6 2CSS255101R0064 SN201-D6 2CSS255101R0061

10 SN201-B10 2CSS255101R0105 SN201-C10 2CSS255101R0104 SN201-D10 2CSS255101R0101

13 - - SN201-C13 2CSS255101R0134 - -

16 SN201-B16 2CSS255101R0165 SN201-C16 2CSS255101R0164 SN201-D16 2CSS255101R0161

20 SN201-B20 2CSS255101R0205 SN201-C20 2CSS255101R0204 SN201-D20 2CSS255101R0201

25 SN201-B25 2CSS255101R0255 SN201-C25 2CSS255101R0254 SN201-D25 2CSS255101R0251

32 SN201-B32 2CSS255101R0325 SN201-C32 2CSS255101R0324 SN201-D32 2CSS255101R0321

40 SN201-B40 2CSS255101R0405 SN201-C40 2CSS255101R0404 SN201-D40 2CSS255101R0401

Series SN201M10kA

Product Hierarchy 2400004

Type B Type CSingle Pole + Switched Neutral Single Pole + Switched Neutral

Rated Current (A) Part Number Order Code Part Number Order Code

2 - - S201M-C2 2CDS275101R0024

4 - - S201M-C4 2CDS275101R0044

6 S201M-B6 2CDS275101R0065 S201M-C6 2CDS275101R0064

10 S201M-B10 2CDS275101R0105 S201M-C10 2CDS275101R0104

16 S201M-B16 2CDS275101R0165 S201M-C16 2CDS275101R0164

20 S201M-B20 2CDS275101R0205 S201M-C20 2CDS275101R0204

25 S201M-B25 2CDS275101R0255 S201M-C25 2CDS275101R0254

32 S201M-B32 2CDS275101R0325 S201M-C32 2CDS275101R0324

40 S201M-B40 2CDS275101R0405 S201M-C40 2CDS275101R0404

3/15

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

DescriptionSPSN Miniature Circuit Breakers in a single module width. Ideal for applications where regulations require the neutral to be switched such as Petrol Stations and Caravan Sites etc.

Technical Details• Current ratings 2 to 40 A at 30 degrees C to BS EN 60898• Rated voltage 230V AC• Maximum operating voltage 250V AC.• Minimum operating voltage 12 V AC/DC• Breaking capacity: BS EN 60898 - 6kA.• Space saving• All poles disconnected in event of a fault• Mechanical service life: 20,000 operations.• Cable capacity: 16mm2 upper and lower terminals.• Weight: 110g• Ambient temperature: -25 to +55ºC

Type S951NC (5-10 In) BS EN 60898.Single pole & switched neutral miniature circuit breakers

Current (A) Weight Kg Order Code Price

2 0.110 S951NC2 14.71

4 0.110 S951NC4 14.71

6 0.110 S951NC6 14.71

10 0.110 S951NC10 14.71

16 0.110 S951NC16 14.71

20 0.110 S951NC20 14.71

25 0.110 S951NC25 14.71

32 0.110 S951NC32 14.71

40 0.110 S951NC40 14.71

C

System ProMSingle pole & switched neutral MCB’s S951N

2CS

C40

0483

F020

1

ABB SF Section 3.5.indd 3/15 15/2/07 11:35:00 am

3/15

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

DescriptionSPSN Miniature Circuit Breakers in a single module width. Ideal for applications where regulations require the neutral to be switched such as Petrol Stations and Caravan Sites etc.

Technical Details• Current ratings 2 to 40 A at 30 degrees C to BS EN 60898• Rated voltage 230V AC• Maximum operating voltage 250V AC.• Minimum operating voltage 12 V AC/DC• Breaking capacity: BS EN 60898 - 6kA.• Space saving• All poles disconnected in event of a fault• Mechanical service life: 20,000 operations.• Cable capacity: 16mm2 upper and lower terminals.• Weight: 110g• Ambient temperature: -25 to +55ºC

Type S951NC (5-10 In) BS EN 60898.Single pole & switched neutral miniature circuit breakers

Current (A) Weight Kg Order Code Price

2 0.110 S951NC2 14.71

4 0.110 S951NC4 14.71

6 0.110 S951NC6 14.71

10 0.110 S951NC10 14.71

16 0.110 S951NC16 14.71

20 0.110 S951NC20 14.71

25 0.110 S951NC25 14.71

32 0.110 S951NC32 14.71

40 0.110 S951NC40 14.71

C

System ProMSingle pole & switched neutral MCB’s S951N

2CS

C40

0483

F020

1

ABB SF Section 3.5.indd 3/15 15/2/07 11:35:00 am

3/15

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

DescriptionSPSN Miniature Circuit Breakers in a single module width. Ideal for applications where regulations require the neutral to be switched such as Petrol Stations and Caravan Sites etc.

Technical Details• Current ratings 2 to 40 A at 30 degrees C to BS EN 60898• Rated voltage 230V AC• Maximum operating voltage 250V AC.• Minimum operating voltage 12 V AC/DC• Breaking capacity: BS EN 60898 - 6kA.• Space saving• All poles disconnected in event of a fault• Mechanical service life: 20,000 operations.• Cable capacity: 16mm2 upper and lower terminals.• Weight: 110g• Ambient temperature: -25 to +55ºC

Type S951NC (5-10 In) BS EN 60898.Single pole & switched neutral miniature circuit breakers

Current (A) Weight Kg Order Code Price

2 0.110 S951NC2 14.71

4 0.110 S951NC4 14.71

6 0.110 S951NC6 14.71

10 0.110 S951NC10 14.71

16 0.110 S951NC16 14.71

20 0.110 S951NC20 14.71

25 0.110 S951NC25 14.71

32 0.110 S951NC32 14.71

40 0.110 S951NC40 14.71

C

System ProMSingle pole & switched neutral MCB’s S951N

2CS

C40

0483

F020

1

ABB SF Section 3.5.indd 3/15 15/2/07 11:35:00 am

Page 23: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

22 Line Protection Equipment 0115 ABB Low Voltage 23 Line Protection Equipment 0115 ABB Low Voltage

Series S800C Type B 25kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

10 S801C-B10 2CCS881001R0105 S802C-B10 2CCS882001R0105 S803C-B10 2CCS883001R0105 S804C-B10 2CCS884001R0105

13 S801C-B13 2CCS881001R0135 S802C-B13 2CCS882001R0135 S803C-B13 2CCS883001R0135 S804C-B13 2CCS884001R0135

16 S801C-B16 2CCS881001R0165 S802C-B16 2CCS882001R0165 S803C-B16 2CCS883001R0165 S804C-B16 2CCS884001R0165

20 S801C-B20 2CCS881001R0205 S802C-B20 2CCS882001R0205 S803C-B20 2CCS883001R0205 S804C-B20 2CCS884001R0205

25 S801C-B25 2CCS881001R0255 S802C-B25 2CCS882001R0255 S803C-B25 2CCS883001R0255 S804C-B25 2CCS884001R0255

32 S801C-B32 2CCS881001R0325 S802C-B32 2CCS882001R0325 S803C-B32 2CCS883001R0325 S804C-B32 2CCS884001R0325

40 S801C-B40 2CCS881001R0405 S802C-B40 2CCS882001R0405 S803C-B40 2CCS883001R0405 S804C-B40 2CCS884001R0405

50 S801C-B50 2CCS881001R0505 S802C-B50 2CCS882001R0505 S803C-B50 2CCS883001R0505 S804C-B50 2CCS884001R0505

63 S801C-B63 2CCS881001R0635 S802C-B63 2CCS882001R0635 S803C-B63 2CCS883001R0635 S804C-B63 2CCS884001R0635

80 S801C-B80 2CCS881001R0805 S802C-B80 2CCS882001R0805 S803C-B80 2CCS883001R0805 S804C-B80 2CCS884001R0805

100 S801C-B100 2CCS881001R0825 S802C-B100 2CCS882001R0825 S803C-B100 2CCS883001R0825 S804C-B100 2CCS884001R0825

125 S801C-B125 2CCS881001R0845 S802C-B125 2CCS882001R0845 S803C-B125 2CCS883001R0845 S804C-B125 2CCS884001R0845

Series S800C Type C 25kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

10 S801C-C10 2CCS881001R0104 S802C-C10 2CCS882001R0104 S803C-C10 2CCS883001R0104 S804C-C10 2CCS884001R0104

13 S801C-C13 2CCS881001R0134 S802C-C13 2CCS882001R0134 S803C-C13 2CCS883001R0134 S804C-C13 2CCS884001R0134

16 S801C-C16 2CCS881001R0164 S802C-C16 2CCS882001R0164 S803C-C16 2CCS883001R0164 S804C-C16 2CCS884001R0164

20 S801C-C20 2CCS881001R0204 S802C-C20 2CCS882001R0204 S803C-C20 2CCS883001R0204 S804C-C20 2CCS884001R0204

25 S801C-C25 2CCS881001R0254 S802C-C25 2CCS882001R0254 S803C-C25 2CCS883001R0254 S804C-C25 2CCS884001R0254

32 S801C-C32 2CCS881001R0324 S802C-C32 2CCS882001R0324 S803C-C32 2CCS883001R0324 S804C-C32 2CCS884001R0324

40 S801C-C40 2CCS881001R0404 S802C-C40 2CCS882001R0404 S803C-C40 2CCS883001R0404 S804C-C40 2CCS884001R0404

50 S801C-C50 2CCS881001R0504 S802C-C50 2CCS882001R0504 S803C-C50 2CCS883001R0504 S804C-C50 2CCS884001R0504

63 S801C-C63 2CCS881001R0634 S802C-C63 2CCS882001R0634 S803C-C63 2CCS883001R0634 S804C-C63 2CCS884001R0634

80 S801C-C80 2CCS881001R0804 S802C-C80 2CCS882001R0804 S803C-C80 2CCS883001R0804 S804C-C80 2CCS884001R0804

100 S801C-C100 2CCS881001R0824 S802C-C100 2CCS882001R0824 S803C-C100 2CCS883001R0824 S804C-C100 2CCS884001R0824

125 S801C-C125 2CCS881001R0844 S802C-C125 2CCS882001R0844 S803C-C125 2CCS883001R0844 S804C-C125 2CCS884001R0844

Series S800C Type D 25kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

10 S801C-D10 2CCS881001R0101 S802C-D10 2CCS882001R0101 S803C-D10 2CCS883001R0101 S804C-D10 2CCS884001R0101

13 S801C-D13 2CCS881001R0131 S802C-D13 2CCS882001R0131 S803C-D13 2CCS883001R0131 S804C-D13 2CCS884001R0131

16 S801C-D16 2CCS881001R0161 S802C-D16 2CCS882001R0161 S803C-D16 2CCS883001R0161 S804C-D16 2CCS884001R0161

20 S801C-D20 2CCS881001R0201 S802C-D20 2CCS882001R0201 S803C-D20 2CCS883001R0201 S804C-D20 2CCS884001R0201

25 S801C-D25 2CCS881001R0251 S802C-D25 2CCS882001R0251 S803C-D25 2CCS883001R0251 S804C-D25 2CCS884001R0251

32 S801C-D32 2CCS881001R0321 S802C-D32 2CCS882001R0321 S803C-D32 2CCS883001R0321 S804C-D32 2CCS884001R0321

40 S801C-D40 2CCS881001R0401 S802C-D40 2CCS882001R0401 S803C-D40 2CCS883001R0401 S804C-D40 2CCS884001R0401

50 S801C-D50 2CCS881001R0501 S802C-D50 2CCS882001R0501 S803C-D50 2CCS883001R0501 S804C-D50 2CCS884001R0501

63 S801C-D63 2CCS881001R0631 S802C-D63 2CCS882001R0631 S803C-D63 2CCS883001R0631 S804C-D63 2CCS884001R0631

80 S801C-D80 2CCS881001R0801 S802C-D80 2CCS882001R0801 S803C-D80 2CCS883001R0801 S804C-D80 2CCS884001R0801

100 S801C-D100 2CCS881001R0821 S802C-D100 2CCS882001R0821 S803C-D100 2CCS883001R0821 S804C-D100 2CCS884001R0821

125 S801C-D125 2CCS881001R0841 S802C-D125 2CCS882001R0841 S803C-D125 2CCS883001R0841 S804C-D125 2CCS884001R0841

System ProM compactS800C series - B, C, D

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

Page 24: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

24 Line Protection Equipment 0115 ABB Low Voltage 25 Line Protection Equipment 0115 ABB Low Voltage

Series S800C Type K 25kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

10 S801C-K10 2CCS881001R0427 S802C-K10 2CCS882001R0427 S803C-K10 2CCS883001R0427 S804C-K10 2CCS884001R0427

13 S801C-K13 2CCS881001R0447 S802C-K13 2CCS882001R0447 S803C-K13 2CCS883001R0447 S804C-K13 2CCS884001R0447

16 S801C-K16 2CCS881001R0467 S802C-K16 2CCS882001R0467 S803C-K16 2CCS883001R0467 S804C-K16 2CCS884001R0467

20 S801C-K20 2CCS881001R0487 S802C-K20 2CCS882001R0487 S803C-K20 2CCS883001R0487 S804C-K20 2CCS884001R0487

25 S801C-K25 2CCS881001R0517 S802C-K25 2CCS882001R0517 S803C-K25 2CCS883001R0517 S804C-K25 2CCS884001R0517

32 S801C-K32 2CCS881001R0537 S802C-K32 2CCS882001R0537 S803C-K32 2CCS883001R0537 S804C-K32 2CCS884001R0537

40 S801C-K40 2CCS881001R0557 S802C-K40 2CCS882001R0557 S803C-K40 2CCS883001R0557 S804C-K40 2CCS884001R0557

50 S801C-K50 2CCS881001R0577 S802C-K50 2CCS882001R0577 S803C-K50 2CCS883001R0577 S804C-K50 2CCS884001R0577

63 S801C-K63 2CCS881001R0597 S802C-K63 2CCS882001R0597 S803C-K63 2CCS883001R0597 S804C-K63 2CCS884001R0597

80 S801C-K80 2CCS881001R0627 S802C-K80 2CCS882001R0627 S803C-K80 2CCS883001R0627 S804C-K80 2CCS884001R0627

100 S801C-K100 2CCS881001R0637 S802C-K100 2CCS882001R0637 S803C-K100 2CCS883001R0637 S804C-K100 2CCS884001R0637

125 S801C-K125 2CCS881001R0647 S802C-K125 2CCS882001R0647 S803C-K125 2CCS883001R0647 S804C-K125 2CCS884001R0647

System ProM compactS800C series - K

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

Page 25: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

24 Line Protection Equipment 0115 ABB Low Voltage 25 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactS800N series - B, C, D

Series S800N Type B 36kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

10 S801N-B10 2CCS891001R0105 S802N-B10 2CCS892001R0105 S803N-B10 2CCS893001R0105 S804N-B10 2CCS894001R0105

13 S801N-B13 2CCS891001R0135 S802N-B13 2CCS892001R0135 S803N-B13 2CCS893001R0135 S804N-B13 2CCS894001R0135

16 S801N-B16 2CCS891001R0165 S802N-B16 2CCS892001R0165 S803N-B16 2CCS893001R0165 S804N-B16 2CCS894001R0165

20 S801N-B20 2CCS891001R0205 S802N-B20 2CCS892001R0205 S803N-B20 2CCS893001R0205 S804N-B20 2CCS894001R0205

25 S801N-B25 2CCS891001R0255 S802N-B25 2CCS892001R0255 S803N-B25 2CCS893001R0255 S804N-B25 2CCS894001R0255

32 S801N-B32 2CCS891001R0325 S802N-B32 2CCS892001R0325 S803N-B32 2CCS893001R0325 S804N-B32 2CCS894001R0325

40 S801N-B40 2CCS891001R0405 S802N-B40 2CCS892001R0405 S803N-B40 2CCS893001R0405 S804N-B40 2CCS894001R0405

50 S801N-B50 2CCS891001R0505 S802N-B50 2CCS892001R0505 S803N-B50 2CCS893001R0505 S804N-B50 2CCS894001R0505

63 S801N-B63 2CCS891001R0635 S802N-B63 2CCS892001R0635 S803N-B63 2CCS893001R0635 S804N-B63 2CCS894001R0635

80 S801N-B80 2CCS891001R0805 S802N-B80 2CCS892001R0805 S803N-B80 2CCS893001R0805 S804N-B80 2CCS894001R0805

100 S801N-B100 2CCS891001R0825 S802N-B100 2CCS892001R0825 S803N-B100 2CCS893001R0825 S804N-B100 2CCS894001R0825

125 S801N-B125 2CCS891001R0845 S802N-B125 2CCS892001R0845 S803N-B125 2CCS893001R0845 S804N-B125 2CCS894001R0845

Series S800N Type C 36kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

10 S801N-C10 2CCS891001R0104 S802N-C10 2CCS892001R0104 S803N-C10 2CCS893001R0104 S804N-C10 2CCS894001R0104

13 S801N-C13 2CCS891001R0134 S802N-C13 2CCS892001R0134 S803N-C13 2CCS893001R0134 S804N-C13 2CCS894001R0134

16 S801N-C16 2CCS891001R0164 S802N-C16 2CCS892001R0164 S803N-C16 2CCS893001R0164 S804N-C16 2CCS894001R0164

20 S801N-C20 2CCS891001R0204 S802N-C20 2CCS892001R0204 S803N-C20 2CCS893001R0204 S804N-C20 2CCS894001R0204

25 S801N-C25 2CCS891001R0254 S802N-C25 2CCS892001R0254 S803N-C25 2CCS893001R0254 S804N-C25 2CCS894001R0254

32 S801N-C32 2CCS891001R0324 S802N-C32 2CCS892001R0324 S803N-C32 2CCS893001R0324 S804N-C32 2CCS894001R0324

40 S801N-C40 2CCS891001R0404 S802N-C40 2CCS892001R0404 S803N-C40 2CCS893001R0404 S804N-C40 2CCS894001R0404

50 S801N-C50 2CCS891001R0504 S802N-C50 2CCS892001R0504 S803N-C50 2CCS893001R0504 S804N-C50 2CCS894001R0504

63 S801N-C63 2CCS891001R0634 S802N-C63 2CCS892001R0634 S803N-C63 2CCS893001R0634 S804N-C63 2CCS894001R0634

80 S801N-C80 2CCS891001R0804 S802N-C80 2CCS892001R0804 S803N-C80 2CCS893001R0804 S804N-C80 2CCS894001R0804

100 S801N-C100 2CCS891001R0824 S802N-C100 2CCS892001R0824 S803N-C100 2CCS893001R0824 S804N-C100 2CCS894001R0824

125 S801N-C125 2CCS891001R0844 S802N-C125 2CCS892001R0844 S803N-C125 2CCS893001R0844 S804N-C125 2CCS894001R0844

Series S800N Type D 36kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

10 S801N-D10 2CCS891001R0101 S802N-D10 2CCS892001R0101 S803N-D10 2CCS893001R0101 S804N-D10 2CCS894001R0101

13 S801N-D13 2CCS891001R0131 S802N-D13 2CCS892001R0131 S803N-D13 2CCS893001R0131 S804N-D13 2CCS894001R0131

16 S801N-D16 2CCS891001R0161 S802N-D16 2CCS892001R0161 S803N-D16 2CCS893001R0161 S804N-D16 2CCS894001R0161

20 S801N-D20 2CCS891001R0201 S802N-D20 2CCS892001R0201 S803N-D20 2CCS893001R0201 S804N-D20 2CCS894001R0201

25 S801N-D25 2CCS891001R0251 S802N-D25 2CCS892001R0251 S803N-D25 2CCS893001R0251 S804N-D25 2CCS894001R0251

32 S801N-D32 2CCS891001R0321 S802N-D32 2CCS892001R0321 S803N-D32 2CCS893001R0321 S804N-D32 2CCS894001R0321

40 S801N-D40 2CCS891001R0401 S802N-D40 2CCS892001R0401 S803N-D40 2CCS893001R0401 S804N-D40 2CCS894001R0401

50 S801N-D50 2CCS891001R0501 S802N-D50 2CCS892001R0501 S803N-D50 2CCS893001R0501 S804N-D50 2CCS894001R0501

63 S801N-D63 2CCS891001R0631 S802N-D63 2CCS892001R0631 S803N-D63 2CCS893001R0631 S804N-D63 2CCS894001R0631

80 S801N-D80 2CCS891001R0801 S802N-D80 2CCS892001R0801 S803N-D80 2CCS893001R0801 S804N-D80 2CCS894001R0801

100 S801N-D100 2CCS891001R0821 S802N-D100 2CCS892001R0821 S803N-D100 2CCS893001R0821 S804N-D100 2CCS894001R0821

125 S801N-D125 2CCS891001R0841 S802N-D125 2CCS892001R0841 S803N-D125 2CCS893001R0841 S804N-D125 2CCS894001R0841

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

Page 26: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

26 Line Protection Equipment 0115 ABB Low Voltage 27 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactS800S series - B, C, K

Series S800S Type B 50kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

6 S801S-B6 2CCS861001R0065 S802S-B6 2CCS862001R0065 S803S-B6 2CCS863001R0065 S804S-B6 2CCS864001R0065

8 S801S-B8 2CCS861001R0085 S802S-B8 2CCS862001R0085 S803S-B8 2CCS863001R0085 S804S-B8 2CCS864001R0085

10 S801S-B10 2CCS861001R0105 S802S-B10 2CCS862001R0105 S803S-B10 2CCS863001R0105 S804S-B10 2CCS864001R0105

16 S801S-B16 2CCS861001R0165 S802S-B16 2CCS862001R0165 S803S-B16 2CCS863001R0165 S804S-B16 2CCS864001R0165

20 S801S-B20 2CCS861001R0205 S802S-B20 2CCS862001R0205 S803S-B20 2CCS863001R0205 S804S-B20 2CCS864001R0205

25 S801S-B25 2CCS861001R0255 S802S-B25 2CCS862001R0255 S803S-B25 2CCS863001R0255 S804S-B25 2CCS864001R0255

32 S801S-B32 2CCS861001R0325 S802S-B32 2CCS862001R0325 S803S-B32 2CCS863001R0325 S804S-B32 2CCS864001R0325

40 S801S-B40 2CCS861001R0405 S802S-B40 2CCS862001R0405 S803S-B40 2CCS863001R0405 S804S-B40 2CCS864001R0405

50 S801S-B50 2CCS861001R0505 S802S-B50 2CCS862001R0505 S803S-B50 2CCS863001R0505 S804S-B50 2CCS864001R0505

63 S801S-B63 2CCS861001R0635 S802S-B63 2CCS862001R0635 S803S-B63 2CCS863001R0635 S804S-B63 2CCS864001R0635

80 S801S-B80 2CCS861001R0805 S802S-B80 2CCS862001R0805 S803S-B80 2CCS863001R0805 S804S-B80 2CCS864001R0805

100 S801S-B100 2CCS861001R0825 S802S-B100 2CCS862001R0825 S803S-B100 2CCS863001R0825 S804S-B100 2CCS864001R0825

125 S801S-B125 2CCS861001R0845 S802S-B125 2CCS862001R0845 S803S-B125 2CCS863001R0845 S804S-B125 2CCS864001R0845

Series S800S Type C 50kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

6 S801S-C6 2CCS861001R0064 S802S-C6 2CCS862001R0064 S803S-C6 2CCS863001R0064 S804S-C6 2CCS864001R0064

8 S801S-C8 2CCS861001R0084 S802S-C8 2CCS862001R0084 S803S-C8 2CCS863001R0084 S804S-C8 2CCS864001R0084

10 S801S-C10 2CCS861001R0104 S802S-C10 2CCS862001R0104 S803S-C10 2CCS863001R0104 S804S-C10 2CCS864001R0104

16 S801S-C16 2CCS861001R0164 S802S-C16 2CCS862001R0164 S803S-C16 2CCS863001R0164 S804S-C16 2CCS864001R0164

20 S801S-C20 2CCS861001R0204 S802S-C20 2CCS862001R0204 S803S-C20 2CCS863001R0204 S804S-C20 2CCS864001R0204

25 S801S-C25 2CCS861001R0254 S802S-C25 2CCS862001R0254 S803S-C25 2CCS863001R0254 S804S-C25 2CCS864001R0254

32 S801S-C32 2CCS861001R0324 S802S-C32 2CCS862001R0324 S803S-C32 2CCS863001R0324 S804S-C32 2CCS864001R0324

40 S801S-C40 2CCS861001R0404 S802S-C40 2CCS862001R0404 S803S-C40 2CCS863001R0404 S804S-C40 2CCS864001R0404

50 S801S-C50 2CCS861001R0504 S802S-C50 2CCS862001R0504 S803S-C50 2CCS863001R0504 S804S-C50 2CCS864001R0504

63 S801S-C63 2CCS861001R0634 S802S-C63 2CCS862001R0634 S803S-C63 2CCS863001R0634 S804S-C63 2CCS864001R0634

80 S801S-C80 2CCS861001R0804 S802S-C80 2CCS862001R0804 S803S-C80 2CCS863001R0804 S804S-C80 2CCS864001R0804

100 S801S-C100 2CCS861001R0824 S802S-C100 2CCS862001R0824 S803S-C100 2CCS863001R0824 S804S-C100 2CCS864001R0824

125 S801S-C125 2CCS861001R0844 S802S-C125 2CCS862001R0844 S803S-C125 2CCS863001R0844 S804S-C125 2CCS864001R0844

Series S800S Type D 50kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

6 S801S-D6 2CCS861001R0061 S802S-D6 2CCS862001R0061 S803S-D6 2CCS863001R0061 S804S-D6 2CCS864001R0061

8 S801S-D8 2CCS861001R0081 S802S-D8 2CCS862001R0081 S803S-D8 2CCS863001R0081 S804S-D8 2CCS864001R0081

10 S801S-D10 2CCS861001R0101 S802S-D10 2CCS862001R0101 S803S-D10 2CCS863001R0101 S804S-D10 2CCS864001R0101

13 S801S-D13 2CCS861001R0131 S802S-D13 2CCS862001R0131 S803S-D13 2CCS863001R0131 S804S-D13 2CCS864001R0131

16 S801S-D16 2CCS861001R0161 S802S-D16 2CCS862001R0161 S803S-D16 2CCS863001R0161 S804S-D16 2CCS864001R0161

20 S801S-D20 2CCS861001R0201 S802S-D20 2CCS862001R0201 S803S-D20 2CCS863001R0201 S804S-D20 2CCS864001R0201

25 S801S-D25 2CCS861001R0251 S802S-D25 2CCS862001R0251 S803S-D25 2CCS863001R0251 S804S-D25 2CCS864001R0251

32 S801S-D32 2CCS861001R0321 S802S-D32 2CCS862001R0321 S803S-D32 2CCS863001R0321 S804S-D32 2CCS864001R0321

40 S801S-D40 2CCS861001R0401 S802S-D40 2CCS862001R0401 S803S-D40 2CCS863001R0401 S804S-D40 2CCS864001R0401

50 S801S-D50 2CCS861001R0501 S802S-D50 2CCS862001R0501 S803S-D50 2CCS863001R0501 S804S-D50 2CCS864001R0501

63 S801S-D63 2CCS861001R0631 S802S-D63 2CCS862001R0631 S803S-D63 2CCS863001R0631 S804S-D63 2CCS864001R0631

80 S801S-D80 2CCS861001R0801 S802S-D80 2CCS862001R0801 S803S-D80 2CCS863001R0801 S804S-D80 2CCS864001R0801

100 S801S-D100 2CCS861001R0821 S802S-D100 2CCS862001R0821 S803S-D100 2CCS863001R0821 S804S-D100 2CCS864001R0821

125 S801S-D125 2CCS861001R0841 S802S-D125 2CCS862001R0841 S803S-D125 2CCS863001R0841 S804S-D125 2CCS864001R0841

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

Page 27: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

26 Line Protection Equipment 0115 ABB Low Voltage 27 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactS800S series - K

Series S800S Type K 50kA

Product Hierarchy 2400003

Single Pole Two Pole Three Pole Four Pole

Rated Current (A) Part Number Order Code Part Number Order Code Part Number Order Code Part Number Order Code

6 S801S-K6 2CCS861001R0067 S802S-K6 2CCS862001R0067 S803S-K6 2CCS863001R0067 S804S-K6 2CCS864001R0067

8 S801S-K8 2CCS861001R0407 S802S-K8 2CCS862001R0407 S803S-K8 2CCS863001R0407 S804S-K8 2CCS864001R0407

10 S801S-K10 2CCS861001R0427 S802S-K10 2CCS862001R0427 S803S-K10 2CCS863001R0427 S804S-K10 2CCS864001R0427

16 S801S-K16 2CCS861001R0467 S802S-K16 2CCS862001R0467 S803S-K16 2CCS863001R0467 S804S-K16 2CCS864001R0467

20 S801S-K20 2CCS861001R0487 S802S-K20 2CCS862001R0487 S803S-K20 2CCS863001R0487 S804S-K20 2CCS864001R0487

25 S801S-K25 2CCS861001R0517 S802S-K25 2CCS862001R0517 S803S-K25 2CCS863001R0517 S804S-K25 2CCS864001R0517

32 S801S-K32 2CCS861001R0537 S802S-K32 2CCS862001R0537 S803S-K32 2CCS863001R0537 S804S-K32 2CCS864001R0537

40 S801S-K40 2CCS861001R0557 S802S-K40 2CCS862001R0557 S803S-K40 2CCS863001R0557 S804S-K40 2CCS864001R0557

50 S801S-K50 2CCS861001R0577 S802S-K50 2CCS862001R0577 S803S-K50 2CCS863001R0577 S804S-K50 2CCS864001R0577

63 S801S-K63 2CCS861001R0597 S802S-K63 2CCS862001R0597 S803S-K63 2CCS863001R0597 S804S-K63 2CCS864001R0597

80 S801S-K80 2CCS861001R0627 S802S-K80 2CCS862001R0627 S803S-K80 2CCS863001R0627 S804S-K80 2CCS864001R0627

100 S801S-K100 2CCS861001R0637 S802S-K100 2CCS862001R0637 S803S-K100 2CCS863001R0637 S804S-K100 2CCS864001R0637

125 S801S-K125 2CCS861001R0647 S802S-K125 2CCS862001R0647 S803S-K125 2CCS863001R0647 S804S-K125 2CCS864001R0647

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

3/18

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProMMCB’s S800 series N-B characteristic - 36kA

S 800 N-B characteristicFunction: protection and control of the circuits against overloads a short-circuits when an high breaking capacity is required; protection for people and big length cables in TN and IT systems; very useful when it is needed selectivity vs an MCCB or back-up vs other MCBs wired downstream.

Applications: commercial and industrial.

Standard: IEC/EN 60898, IEC/EN 60947-2

Icn=36 kA

RatedCurrent (A)

Single Pole Price Double Pole Price Triple Pole Price Four Pole Price

10 S801N-B10 28.32 S802N-B10 56.63 S803N-B10 82.37 S804N-B10 110.69

13 S801N-B13 28.32 S802N-B13 56.63 S803N-B13 82.37 S804N-B13 110.69

16 S801N-B16 28.32 S802N-B16 56.63 S803N-B16 82.37 S804N-B16 110.69

20 S801N-B20 28.32 S802N-B20 56.63 S803N-B20 82.37 S804N-B20 110.69

25 S801N-B25 28.32 S802N-B25 56.63 S803N-B25 82.37 S804N-B25 110.69

32 S801N-B32 28.32 S802N-B32 56.63 S803N-B32 82.37 S804N-B32 110.69

40 S801N-B40 29.74 S802N-B40 59.21 S803N-B40 87.52 S804N-B40 117.26

50 S801N-B50 31.18 S802N-B50 61.78 S803N-B50 92.66 S804N-B50 122.41

63 S801N-B63 34.04 S802N-B63 66.64 S803N-B63 100.39 S804N-B63 130.71

80 S801N-B80 39.47 S802N-B80 78.94 S803N-B80 115.84 S804N-B80 154.44

100 S801N-B100 39.47 S802N-B100 78.94 S803N-B100 115.84 S804N-B100 154.44

125 S801N-B125 41.18 S802N-B125 84.95 S803N-B125 123.55 S804N-B125 166.17

B

ABB SF Section 3.5.indd 3/18 15/2/07 11:35:13 am

Page 28: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

28 Line Protection Equipment 0115 ABB Low Voltage 29 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactEarth leakage introduction

Test pushbutton to verify the correct functioning of the device

Imformation on the device are laser printed to make them clearly visible and long lasting

Contact position indicator (CPI): to always know the status of the contacts (red: closed contacts; green: open contacts) independently on the toggle position

Laser marked order code on the front to make easier future orders

Bi-directional cylindrical terminal ensure higher safety of connecting operations, making them easier

Page 29: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

28 Line Protection Equipment 0115 ABB Low Voltage 29 Line Protection Equipment 0115 ABB Low Voltage

í

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï íñë

Ì©± ¬»®³·²¿´­ ¿®» ¿ª¿·´¿¾´»ô ¬¸» º±®» ±²»

º±® ½¿¾´»­ «° ¬± îë ³³îô ¬¸» ¾¿½µ ±²»

º±® ½¿¾´»­ «° ¬± ïð ³³î ±® º±® ¾«­¾¿®­ò

ÎÝÝÞ­ Úîð𠽿² ¾» «­»¼ ·² ¿³¾·»²¬

½±²¼·¬·±²­ ©¸»®» ¬¸» ¬»³°»®¿¬«®» ±º

¬¸» ­«®®±«²¼·²¹ ¿¬³±­°¸»®» ¸¿­ ª¿´«»­

¾»¬©»»² óîëpÝ ø­²±©º´¿µ» ´¿­»® °®·²¬»¼

±² ¬¸» º®±²¬ ±º ¬¸» ¼»ª·½»÷ ¿²¼ õëëpÝò

̸» ¿ª¿·´¿¾·´·¬§ ±º ¬©± ¬»®³·²¿´­ ±ºº»®­

¼·ºº»®»²¬ ½±²²»½¬·±² ­±´«¬·±²­ ¬¸¿²µ­ ¬±

¬¸» °±­­·¾·´·¬§ ¬± ½±²²»½¬ ¬©± ·²¼·°»²ó

¼»²¬ ½¿¾´»­ ·² ¬¸» ­¿³» ¼»ª·½»æ ¬¸»

­»½±²¼ ¬»®³·²¿´ ½¿² ¾» «­»¼ º±® ¿²

¿«¨·´·¿®§ ½·®½«·¬ ±® º±® ¬¸» ­«°°´§ ±º ¼»ó

ª·½»­ ©·¬¸ ­³¿´´ ­»½¬·±² ½¿¾´»­ ©·¬¸±«¬

½±²²»½¬·²¹ ¬¸»³ ¬±¹»¬¸»® ©·¬¸ ¬¸» ³¿·²

½·®½«·¬ò

ß´´ ¬¸» ­¿º»¬§ »²­«®»¼ ¾§ ¬¸» ·²¬»®²¿ó

¬·±²¿´ ³¿®µ­æ ¿°°®±ª¿´­ ³¿®µ·²¹ ·² ¿

ª·­·¾´» ¿®»¿ô »ª»² ·º ÎÝÜ­ ·­ ·²­¬¿´´»¼

¿²¼ ©·¬¸ ¬¸» °¿²»´ó¼±±® ½´±­»¼ò

Ø·¹¸ °»®º±®³¿²½»­æ

®¿¬»¼ ¾®»¿µ·²¹ ½¿°¿½·¬§ ¿²¼ ®¿¬»¼ ®»ó

­·¼«¿´ ¾®»¿µ·²¹ ½¿°¿½·¬§ ´¿­»® °®·²¬»¼

½±±®¼·²¿¬·±² ©·¬¸ ¿ ïðð ß ®¿¬»¼ ½«®ó

®»²¬ ÍÝÐÜ ø­¸±®¬ó½·®½«·¬ °®±¬»½¬·ª»

¼»ª·½»÷ ã ïðððð ßò

̸» Ú îðî ½¿² ¾» ½±«°´»¼ ©·¬¸ ¬¸»

¿«¬±®»½´±­·²¹ «²·¬ ÚîÝóßÎØ ·² ±®¼»®

¬± »²­«®» ½±²¬·²«·¬§ ±º ­»®ª·½» º±® ¬¸»

©¸±´» ·²­¬¿´´¿¬·±² ±º §±«® ¸±³» ¿ª± ¼·²¹

´¿½µ ±º ­«°°´§ò

Page 30: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

30 Line Protection Equipment 0115 ABB Low Voltage 31 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactF200 AC, A - 2 & 4 pole RCCBs

3/32

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

F 200 AC typeFunction: protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30 mA) contacts; command and isolation of resistive and inductive circuits.

Application: residential, commercial, industrial.

Standard: IEC/EN 61008, UL 1053

Marking: according to EN 61008

Sensitivity in mA Rated current In A Double Pole Price Four Pole Price

10 16 F202 AC-16/0.01 66.67 - -

30 25 F202 AC-25/0.03 51.08 F204 AC-25/0.03 54.17

40 F202 AC-40/0.03 53.93 F204 AC-40/0.03 65.89

63 F202 AC-63/0.03 64.92 F204 AC-63/0.03 93.44

80 F202 AC-80/0.03 80.32 F204 AC-80/0.03 116.23

100 F202 AC-100/0.03 94.21 F204 AC-100/0.03 130.79

100 25 F202 AC-25/0.1 50.73 F204 AC-25/0.1 54.85

40 F202 AC-40/0.1 53.71 F204 AC-40/0.1 62.17

63 F202 AC-63/0.1 58.13 F204 AC-63/0.1 67.23

80 F202 AC-80/0.1 61.94 F204 AC-80/0.1 116.23

100 F202 AC-100/0.1 75.46 F204 AC-100/0.1 130.79

300 25 F202 AC-25/0.3 47.81 F204 AC-25/0.3 53.09

40 F202 AC-40/0.3 48.77 F204 AC-40/0.3 55.09

63 F202 AC-63/0.3 54.80 F204 AC-63/0.3 61.39

80 F202 AC-80/0.3 60.10 F204 AC-80/0.3 116.23

100 F202 AC-100/0.3 72.18 F204 AC-100/0.3 130.79

System ProM CompactRCCB’s F200 series AC type

AC

2CS

C40

0565

F020

12C

SC

4005

69F0

201

ABB SF Section 3.5.indd 3/32 15/2/07 11:36:19 am

3/32

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

F 200 AC typeFunction: protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30 mA) contacts; command and isolation of resistive and inductive circuits.

Application: residential, commercial, industrial.

Standard: IEC/EN 61008, UL 1053

Marking: according to EN 61008

Sensitivity in mA Rated current In A Double Pole Price Four Pole Price

10 16 F202 AC-16/0.01 66.67 - -

30 25 F202 AC-25/0.03 51.08 F204 AC-25/0.03 54.17

40 F202 AC-40/0.03 53.93 F204 AC-40/0.03 65.89

63 F202 AC-63/0.03 64.92 F204 AC-63/0.03 93.44

80 F202 AC-80/0.03 80.32 F204 AC-80/0.03 116.23

100 F202 AC-100/0.03 94.21 F204 AC-100/0.03 130.79

100 25 F202 AC-25/0.1 50.73 F204 AC-25/0.1 54.85

40 F202 AC-40/0.1 53.71 F204 AC-40/0.1 62.17

63 F202 AC-63/0.1 58.13 F204 AC-63/0.1 67.23

80 F202 AC-80/0.1 61.94 F204 AC-80/0.1 116.23

100 F202 AC-100/0.1 75.46 F204 AC-100/0.1 130.79

300 25 F202 AC-25/0.3 47.81 F204 AC-25/0.3 53.09

40 F202 AC-40/0.3 48.77 F204 AC-40/0.3 55.09

63 F202 AC-63/0.3 54.80 F204 AC-63/0.3 61.39

80 F202 AC-80/0.3 60.10 F204 AC-80/0.3 116.23

100 F202 AC-100/0.3 72.18 F204 AC-100/0.3 130.79

System ProM CompactRCCB’s F200 series AC type

AC

2CS

C40

0565

F020

12C

SC

4005

69F0

201

ABB SF Section 3.5.indd 3/32 15/2/07 11:36:19 am

F200 AC Type RCCBs 2 & 4 PoleAC - BS/EN 61008

Product Hierarchy 2500001

Two Pole Four Pole

Rated Current Tripping mA Part No Order Code Part No Order Code25

30

F202 AC-25/0.03 2CSF202001R1250 F204 AC-25/0.03 2CSF204001R1250

40 F202 AC-40/0.03 2CSF202001R1400 F204 AC-40/0.03 2CSF204001R1400

63 F202 AC-63/0.03 2CSF202001R1630 F204 AC-63/0.03 2CSF204001R1630

80 F202 AC-80/0.03 2CSF202001R1800 F204 AC-80/0.03 2CSF204001R1800

100 F202 AC-100/0.03 2CSF202001R1900 F204 AC-100/0.03 2CSF204001R1900

125 - - F204 AC-125/0.03 2CSF204001R1950

25

100

F202 AC-25/0.1 2CSF202001R2250 F204 AC-25/0.1 2CSF204001R2250

40 F202 AC-40/0.1 2CSF202001R2400 F204 AC-40/0.1 2CSF204001R2400

63 F202 AC-63/0.1 2CSF202001R2630 F204 AC-63/0.1 2CSF204001R2630

80 F202 AC-80/0.1 2CSF202001R2800 F204 AC-80/0.1 2CSF204001R2800

100 F202 AC-100/0.1 2CSF202001R2900 F204 AC-100/0.1 2CSF204001R2900

125 - - F204 AC-125/0.1 2CSF204001R2950

25

300

F202 AC-25/0.3 2CSF202001R3250 F204 AC-25/0.3 2CSF204001R3250

40 F202 AC-40/0.3 2CSF202001R3400 F204 AC-40/0.3 2CSF204001R3400

63 F202 AC-63/0.3 2CSF202001R3630 F204 AC-63/0.3 2CSF204001R3630

80 F202 AC-80/0.3 2CSF202001R3800 F204 AC-80/0.3 2CSF204001R3800

100 F202 AC-100/0.3 2CSF202001R3900 F204 AC-100/0.3 2CSF204001R3900

125 - - F204 AC-125/0.3 2CSF204001R3950

F200 A Type RCCBs 2 & 4 PoleAC - BS/EN 61008

Product Hierarchy 2500001

Two Pole Four Pole

Rated Current Tripping mA Part No Order Code Part No Order Code16 10 F202 A-16/0.01 2CSF202101R0160 - -

25

30

F202 A-25/0.03 2CSF202101R1250 F204 A-25/0.03 2CSF204101R1250

40 F202 A-40/0.03 2CSF202101R1400 F204 A-40/0.03 2CSF204101R1400

63 F202 A-63/0.03 2CSF202101R1630 F204 A-63/0.03 2CSF204101R1630

80 F202 A-80/0.03 2CSF202101R1800 F204 A-80/0.03 2CSF204101R1800

100 F202 A-100/0.03 2CSF202101R1900 F204 A-100/0.03 2CSF204101R1900

125 - - F204 A-125/0.03 2CSF204101R1950

25

100

F202 A-25/0.1 2CSF202101R2250 F204 A-25/0.1 2CSF204101R2250

40 F202 A-40/0.1 2CSF202101R2400 F204 A-40/0.1 2CSF204101R2400

63 F202 A-63/0.1 2CSF202101R2630 F204 A-63/0.1 2CSF204101R2630

80 F202 A-80/0.1 2CSF202101R2800 F204 A-80/0.1 2CSF204101R2800

100 F202 A-100/0.1 2CSF202101R2900 F204 A-100/0.1 2CSF204101R2900

125 - - F204 A-125/0.1 2CSF204101R2950

25

300

F202 A-25/0.3 2CSF202101R3250 F204 A-25/0.3 2CSF204101R3250

40 F202 A-40/0.3 2CSF202101R3400 F204 A-40/0.3 2CSF204101R3400

63 F202 A-63/0.3 2CSF202101R3630 F204 A-63/0.3 2CSF204101R3630

80 F202 A-80/0.3 2CSF202101R3800 F204 A-80/0.3 2CSF204101R3800

100 F202 A-100/0.3 2CSF202101R3900 F204 A-100/0.3 2CSF204101R3900

125 - - F204 A-125/0.3 2CSF204101R3950

3/32

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

F 200 AC typeFunction: protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30 mA) contacts; command and isolation of resistive and inductive circuits.

Application: residential, commercial, industrial.

Standard: IEC/EN 61008, UL 1053

Marking: according to EN 61008

Sensitivity in mA Rated current In A Double Pole Price Four Pole Price

10 16 F202 AC-16/0.01 66.67 - -

30 25 F202 AC-25/0.03 51.08 F204 AC-25/0.03 54.17

40 F202 AC-40/0.03 53.93 F204 AC-40/0.03 65.89

63 F202 AC-63/0.03 64.92 F204 AC-63/0.03 93.44

80 F202 AC-80/0.03 80.32 F204 AC-80/0.03 116.23

100 F202 AC-100/0.03 94.21 F204 AC-100/0.03 130.79

100 25 F202 AC-25/0.1 50.73 F204 AC-25/0.1 54.85

40 F202 AC-40/0.1 53.71 F204 AC-40/0.1 62.17

63 F202 AC-63/0.1 58.13 F204 AC-63/0.1 67.23

80 F202 AC-80/0.1 61.94 F204 AC-80/0.1 116.23

100 F202 AC-100/0.1 75.46 F204 AC-100/0.1 130.79

300 25 F202 AC-25/0.3 47.81 F204 AC-25/0.3 53.09

40 F202 AC-40/0.3 48.77 F204 AC-40/0.3 55.09

63 F202 AC-63/0.3 54.80 F204 AC-63/0.3 61.39

80 F202 AC-80/0.3 60.10 F204 AC-80/0.3 116.23

100 F202 AC-100/0.3 72.18 F204 AC-100/0.3 130.79

System ProM CompactRCCB’s F200 series AC type

AC

2CS

C40

0565

F020

12C

SC

4005

69F0

201

ABB SF Section 3.5.indd 3/32 15/2/07 11:36:19 am

3/32

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

F 200 AC typeFunction: protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30 mA) contacts; command and isolation of resistive and inductive circuits.

Application: residential, commercial, industrial.

Standard: IEC/EN 61008, UL 1053

Marking: according to EN 61008

Sensitivity in mA Rated current In A Double Pole Price Four Pole Price

10 16 F202 AC-16/0.01 66.67 - -

30 25 F202 AC-25/0.03 51.08 F204 AC-25/0.03 54.17

40 F202 AC-40/0.03 53.93 F204 AC-40/0.03 65.89

63 F202 AC-63/0.03 64.92 F204 AC-63/0.03 93.44

80 F202 AC-80/0.03 80.32 F204 AC-80/0.03 116.23

100 F202 AC-100/0.03 94.21 F204 AC-100/0.03 130.79

100 25 F202 AC-25/0.1 50.73 F204 AC-25/0.1 54.85

40 F202 AC-40/0.1 53.71 F204 AC-40/0.1 62.17

63 F202 AC-63/0.1 58.13 F204 AC-63/0.1 67.23

80 F202 AC-80/0.1 61.94 F204 AC-80/0.1 116.23

100 F202 AC-100/0.1 75.46 F204 AC-100/0.1 130.79

300 25 F202 AC-25/0.3 47.81 F204 AC-25/0.3 53.09

40 F202 AC-40/0.3 48.77 F204 AC-40/0.3 55.09

63 F202 AC-63/0.3 54.80 F204 AC-63/0.3 61.39

80 F202 AC-80/0.3 60.10 F204 AC-80/0.3 116.23

100 F202 AC-100/0.3 72.18 F204 AC-100/0.3 130.79

System ProM CompactRCCB’s F200 series AC type

AC

2CS

C40

0565

F020

12C

SC

4005

69F0

201

ABB SF Section 3.5.indd 3/32 15/2/07 11:36:19 am

Page 31: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

30 Line Protection Equipment 0115 ABB Low Voltage 31 Line Protection Equipment 0115 ABB Low Voltage

3/36

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

System ProM CompactRCD-blocks DDA 200 series AC type

2CS

C40

0163

F020

12C

SC

4001

64F0

201

2CS

C40

0165

F020

1

ACDDA 200 AC typeFunction: RCD-block for assembly on site with MCBs S 200 series. Protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30 mA) contacts.

Application: residential, commercial, industrial.

Standard: IEC/EN 61009 Ann. G

Rated Current In A: 63A

Rated residual current Double Pole Price Triple Pole Price Four Pole Price

30 DDA202 AC-63/0.032) 55.04 DDA203 AC-63/0.032) 66.50 DDA204 AC-63/0.031)2) 72.69

100 DDA202 AC-63/0.12) 68.07 DDA203 AC-63/0.12) 66.50 DDA204 AC-63/0.12) 72.69

300 DDA202 AC-63/0.32) 57.64 DDA203 AC-63/0.32) 61.53 DDA204 AC-63/0.32) 66.85

1) version with test button working at 115V AC - 127V AC is available on request2) provided with additional terminals for remote tripping

ABB SF Section 3.5.indd 3/36 15/2/07 11:36:23 am

DDA 200 AC type Product Hierarchy 2500001

Two Pole Three Pole Four Pole

Rated Current Tripping mA Part No Order Code Part No Order Code Part No Order Code25 10 DDA202 AC-25/0.01 2CSB202001R0250 - - - -

25

30

DDA202 AC-25/0.03 2CSB202001R1250 DDA203 AC-25/0.03 2CSB203001R1250 DDA204 AC-25/0.03 2CSB204001R1250

40 DDA202 AC-40/0.03 2CSB202001R1400 DDA203 AC-40/0.03 2CSB203001R1400 DDA204 AC-40/0.03 2CSB204001R1400

63 DDA202 AC-63/0.03 2CSB202001R1630 DDA203 AC-63/0.03 2CSB203001R1630 DDA204 AC-63/0.03 2CSB204001R1630

25

100

DDA202 AC-25/0.1 2CSB202001R2250 DDA203 AC-25/0.1 2CSB203001R2250 DDA204 AC-25/0.1 2CSB204001R2250

40 DDA202 AC-40/0.1 2CSB202001R2400 DDA203 AC-40/0.1 2CSB203001R2400 DDA204 AC-40/0.1 2CSB204001R2400

63 DDA202 AC-63/0.1 2CSB202001R2630 DDA203 AC-63/0.1 2CSB203001R2630 DDA204 AC-63/0.1 2CSB204001R2630

25

300

DDA204 AC-25/0.3 2CSB202001R3250 DDA203 AC-25/0.3 2CSB203001R3250 DDA204 AC-25/0.3 2CSB204001R3250

40 DDA204 AC-40/0.3 2CSB202001R3400 DDA203 AC-40/0.3 2CSB203001R3400 DDA204 AC-40/0.3 2CSB204001R3400

63 DDA204 AC-63/0.3 2CSB202001R3630 DDA203 AC-63/0.3 2CSB203001R3630 DDA204 AC-63/0.3 2CSB204001R3630

System ProM compactDDA200 AC - 2, 3, 4 pole RCD block

DDA800 A_ type - 2, 3, 4 RCBO (for S800)

DDA800 50kA Product Hierarchy 2500001

Two Pole Three Pole Four Pole

Rated Current Type Tripping mA Part No Order Code Part No Order Code Part No Order Code

63A

A

30

DDA802A-63/0,03 2CSB802101R1630 DDA803A-63/0,03 2CSB803101R1630 DDA804A-63/0,03 2CSB804101R1630

AC DDA802AC-63/0,03 2CSB802001R1630 DDA803AC-63/0,03 2CSB803001R1630 DDA804AC-63/0,03 2CSB804001R1630

AP-R DDA802A-63/0,03 AP-R 2CSB802401R1630 DDA803A-63/0,03AP-R 2CSB803401R1630 DDA804A-63/0,03AP-R 2CSB804401R1630

A

300

DDA802A-63/0,3 2CSB802101R3630 DDA803A-63/0,3 2CSB803101R3630 DDA804A-63/0,3 2CSB804101R3630

AC DDA802AC-63/0,3 2CSB802001R3630 DDA803AC-63/0,3 2CSB803001R3630 DDA804AC-63/0,3 2CSB804001R3630

AS DDA802AS-63/0,3 2CSB802201R3630 DDA803AS-63/0,3 2CSB803201R3630 DDA804AS-63/0,3 2CSB804201R3630

A 500 DDA802A-63/0,5 2CSB802101R4630 DDA803A-63/0,5 2CSB803101R4630 DDA804A-63/0,5 2CSB804101R4630

AS 1000 DDA802AS-63/1 2CSB802201R5630 DDA803AS-63/1 2CSB803201R5630 DDA804AS-63/1 2CSB804201R5630

100A

AP-R 30 DDA802A-100/0,03 AP-R 2CSB802401R1000 DDA803A-100/0,03 AP-R 2CSB803401R1000 DDA804A-100/0,03 AP-R 2CSB804401R1000

A300

DDA802A-100/0,3 2CSB802101R3000 DDA803A-100/0,3 2CSB803101R3000 DDA804 A-100/0,3 2CSB804101R3000

AS DDA802AS-100/0,3 2CSB802201R3000 DDA803AS-100/0,3 2CSB803201R3000 DDA804AS-100/0,3 2CSB804201R3000

A 500 DDA802A-100/0,5 2CSB802101R4000 DDA803A-100/0,5 2CSB803101R4000 DDA804A-100/0,5 2CSB804101R4000

AS 1000 DDA802AS-100/1 2CSB802201R5000 DDA803AS-100/1 2CSB803201R5000 DDA804AS-100/1 2CSB804201R5000

í

íñéè ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ÜÜß èðð ßÝ ¬§°» º±® ÓÝÞ­ Íèðð

Ú«²½¬·±²æ ÎÝÜó¾´±½µ º±® ¿­­»³¾´§ ±² ­·¬» ©·¬¸ ÓÝÞ­ Íèðð ­»®·»­ «° ¬± êí ßò Ю±¬»½¬·±²

¿¹¿·²­¬ ¬¸» »ºº»½¬­ ±º ­·²«­±·¼¿´ ¿´¬»®²¿¬·²¹ »¿®¬¸ º¿«´¬ ½«®®»²¬­å °®±¬»½¬·±² ¿¹¿·²­¬ ·²¼·®»½¬ ½±²ó

¬¿½¬­ ¿²¼ ¿¼¼·¬·±²¿´ °®±¬»½¬·±² ¿¹¿·²­¬ ¼·®»½¬ ½±²¬¿½¬­ ø©·¬¸ × ²ãíð ³ß÷ò

ß°°´·½¿¬·±²æ ½±³³»®½·¿´ô ·²¼«­¬®·¿´ò

ͬ¿²¼¿®¼æ ×ÛÝñÛÒ êðçìéóî ß²²ò Þ

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

î íð êí çïçéðì ÜÜßèðîßÝóêíñðòðí îÝÍÞèðîððïÎïêíð ðòíðð ï

íðð êí çïççðî ÜÜßèðîßÝóêíñðòí îÝÍÞèðîððïÎíêíð ðòíðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

í íð êí çîîððï ÜÜßèðíßÝóêíñðòðí îÝÍÞèðíððïÎïêíð ðòìðð ï

íðð êí çîîîðç ÜÜßèðíßÝóêíñðòí îÝÍÞèðíððïÎíêíð ðòìðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ì íð êí çîììðï ÜÜßèðìßÝóêíñðòðí îÝÍÞèðìððïÎïêíð ðòìêð ï

íðð êí çîìêðç ÜÜßèðìßÝóêíñðòí îÝÍÞèðìððïÎíêíð ðòìêð ï

ÎÝÜó¾´±½µ­ ÜÜß èðð ßÝ © ¬§°» º±® ÓÝÞ­ Íèðð

îÝ

ÍÝ

ìð

ðï

éé

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éè

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éç

Úð

îð

ï

ÜÜß èðî

ÜÜß èðí

ÜÜß èðì

ɸ»®» ¬± º·²¼ ³±®»æÌ»½¸²·½¿´ ¹«·¼» ±º ÎÝÜ­ ø½±¼» îÝÍÝìîðððìÞðîðï÷

Ú®»¯«»²¬´§ ¿­µ»¼ ¯«»­¬·±² ó ÚßÏæß ½±³°´»¬» ´·­¬ ±º ¿²­©»®­ ·­ ¿ª¿·´¿¾´» ·² ¬¸» ÎÝÜ­ ÚßÏ ¼±½«³»²¬ ¬ ø½±¼» îÝÍÝìîðððëÞðîðï÷

Ó¿§¾» §±« ¿®» ¿´­± ·²¬»®»­¬»¼ ·²æß«¨·´·¿®§ Û´»³»²¬­ ¿²¼ ß½½»­­±®·»­ º±® Íèðð ¿²¼ ÜÜß èðð °òìñêî

í

íñéè ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ÜÜß èðð ßÝ ¬§°» º±® ÓÝÞ­ Íèðð

Ú«²½¬·±²æ ÎÝÜó¾´±½µ º±® ¿­­»³¾´§ ±² ­·¬» ©·¬¸ ÓÝÞ­ Íèðð ­»®·»­ «° ¬± êí ßò Ю±¬»½¬·±²

¿¹¿·²­¬ ¬¸» »ºº»½¬­ ±º ­·²«­±·¼¿´ ¿´¬»®²¿¬·²¹ »¿®¬¸ º¿«´¬ ½«®®»²¬­å °®±¬»½¬·±² ¿¹¿·²­¬ ·²¼·®»½¬ ½±²ó

¬¿½¬­ ¿²¼ ¿¼¼·¬·±²¿´ °®±¬»½¬·±² ¿¹¿·²­¬ ¼·®»½¬ ½±²¬¿½¬­ ø©·¬¸ × ²ãíð ³ß÷ò

ß°°´·½¿¬·±²æ ½±³³»®½·¿´ô ·²¼«­¬®·¿´ò

ͬ¿²¼¿®¼æ ×ÛÝñÛÒ êðçìéóî ß²²ò Þ

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

î íð êí çïçéðì ÜÜßèðîßÝóêíñðòðí îÝÍÞèðîððïÎïêíð ðòíðð ï

íðð êí çïççðî ÜÜßèðîßÝóêíñðòí îÝÍÞèðîððïÎíêíð ðòíðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

í íð êí çîîððï ÜÜßèðíßÝóêíñðòðí îÝÍÞèðíððïÎïêíð ðòìðð ï

íðð êí çîîîðç ÜÜßèðíßÝóêíñðòí îÝÍÞèðíððïÎíêíð ðòìðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ì íð êí çîììðï ÜÜßèðìßÝóêíñðòðí îÝÍÞèðìððïÎïêíð ðòìêð ï

íðð êí çîìêðç ÜÜßèðìßÝóêíñðòí îÝÍÞèðìððïÎíêíð ðòìêð ï

ÎÝÜó¾´±½µ­ ÜÜß èðð ßÝ © ¬§°» º±® ÓÝÞ­ Íèðð

îÝ

ÍÝ

ìð

ðï

éé

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éè

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éç

Úð

îð

ï

ÜÜß èðî

ÜÜß èðí

ÜÜß èðì

ɸ»®» ¬± º·²¼ ³±®»æÌ»½¸²·½¿´ ¹«·¼» ±º ÎÝÜ­ ø½±¼» îÝÍÝìîðððìÞðîðï÷

Ú®»¯«»²¬´§ ¿­µ»¼ ¯«»­¬·±² ó ÚßÏæß ½±³°´»¬» ´·­¬ ±º ¿²­©»®­ ·­ ¿ª¿·´¿¾´» ·² ¬¸» ÎÝÜ­ ÚßÏ ¼±½«³»²¬ ¬ ø½±¼» îÝÍÝìîðððëÞðîðï÷

Ó¿§¾» §±« ¿®» ¿´­± ·²¬»®»­¬»¼ ·²æß«¨·´·¿®§ Û´»³»²¬­ ¿²¼ ß½½»­­±®·»­ º±® Íèðð ¿²¼ ÜÜß èðð °òìñêî

í

íñéè ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ÜÜß èðð ßÝ ¬§°» º±® ÓÝÞ­ Íèðð

Ú«²½¬·±²æ ÎÝÜó¾´±½µ º±® ¿­­»³¾´§ ±² ­·¬» ©·¬¸ ÓÝÞ­ Íèðð ­»®·»­ «° ¬± êí ßò Ю±¬»½¬·±²

¿¹¿·²­¬ ¬¸» »ºº»½¬­ ±º ­·²«­±·¼¿´ ¿´¬»®²¿¬·²¹ »¿®¬¸ º¿«´¬ ½«®®»²¬­å °®±¬»½¬·±² ¿¹¿·²­¬ ·²¼·®»½¬ ½±²ó

¬¿½¬­ ¿²¼ ¿¼¼·¬·±²¿´ °®±¬»½¬·±² ¿¹¿·²­¬ ¼·®»½¬ ½±²¬¿½¬­ ø©·¬¸ × ²ãíð ³ß÷ò

ß°°´·½¿¬·±²æ ½±³³»®½·¿´ô ·²¼«­¬®·¿´ò

ͬ¿²¼¿®¼æ ×ÛÝñÛÒ êðçìéóî ß²²ò Þ

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

î íð êí çïçéðì ÜÜßèðîßÝóêíñðòðí îÝÍÞèðîððïÎïêíð ðòíðð ï

íðð êí çïççðî ÜÜßèðîßÝóêíñðòí îÝÍÞèðîððïÎíêíð ðòíðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

í íð êí çîîððï ÜÜßèðíßÝóêíñðòðí îÝÍÞèðíððïÎïêíð ðòìðð ï

íðð êí çîîîðç ÜÜßèðíßÝóêíñðòí îÝÍÞèðíððïÎíêíð ðòìðð ï

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ì íð êí çîììðï ÜÜßèðìßÝóêíñðòðí îÝÍÞèðìððïÎïêíð ðòìêð ï

íðð êí çîìêðç ÜÜßèðìßÝóêíñðòí îÝÍÞèðìððïÎíêíð ðòìêð ï

ÎÝÜó¾´±½µ­ ÜÜß èðð ßÝ © ¬§°» º±® ÓÝÞ­ Íèðð

îÝ

ÍÝ

ìð

ðï

éé

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éè

Úð

îð

ï

îÝ

ÍÝ

ìð

ðï

éç

Úð

îð

ï

ÜÜß èðî

ÜÜß èðí

ÜÜß èðì

ɸ»®» ¬± º·²¼ ³±®»æÌ»½¸²·½¿´ ¹«·¼» ±º ÎÝÜ­ ø½±¼» îÝÍÝìîðððìÞðîðï÷

Ú®»¯«»²¬´§ ¿­µ»¼ ¯«»­¬·±² ó ÚßÏæß ½±³°´»¬» ´·­¬ ±º ¿²­©»®­ ·­ ¿ª¿·´¿¾´» ·² ¬¸» ÎÝÜ­ ÚßÏ ¼±½«³»²¬ ¬ ø½±¼» îÝÍÝìîðððëÞðîðï÷

Ó¿§¾» §±« ¿®» ¿´­± ·²¬»®»­¬»¼ ·²æß«¨·´·¿®§ Û´»³»²¬­ ¿²¼ ß½½»­­±®·»­ º±® Íèðð ¿²¼ ÜÜß èðð °òìñêî

Page 32: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

32 Line Protection Equipment 0115 ABB Low Voltage 33 Line Protection Equipment 0115 ABB Low Voltage

System ProM compactDS201M AC B, C - 1+N pole RCBO

DS201M AC1+N - Type B, C 10kA

Product Hierarchy 2500001

Type B Type CRated Current Tripping mA Part No Order Code Part No Order Code6

30

DS201M-B6 AC30 2CSR275040R1065 DS201M-C6 AC30 2CSR275040R1064

10 DS201M-B10 AC30 2CSR275040R1105 DS201M-C10 AC30 2CSR275040R1104

13 DS201M-B13 AC30 2CSR275040R1135 DS201M-C13 AC30 2CSR275040R1134

16 DS201M-B16 AC30 2CSR275040R1165 DS201M-C16 AC30 2CSR275040R1164

20 DS201M-B20 AC30 2CSR275040R1205 DS201M-C20 AC30 2CSR275040R1204

25 DS201M-B25 AC30 2CSR275040R1255 DS201M-C25 AC30 2CSR275040R1254

32 DS201M-B32 AC30 2CSR275040R1325 DS201M-C32 AC30 2CSR275040R1324

40 DS201M-B40 AC30 2CSR275040R1405 DS201M-C40 AC30 2CSR275040R1404

6

100

DS201M-B6 AC100 2CSR275040R2065 DS201M-C6 AC100 2CSR275040R2064

10 DS201M-B10 AC100 2CSR275040R2105 DS201M-C10 AC100 2CSR275040R2104

13 DS201M-B13 AC100 2CSR275040R2135 DS201M-C13 AC100 2CSR275040R2134

16 DS201M-B16 AC100 2CSR275040R2165 DS201M-C16 AC100 2CSR275040R2164

20 DS201M-B20 AC100 2CSR275040R2205 DS201M-C20 AC100 2CSR275040R2204

25 DS201M-B25 AC100 2CSR275040R2255 DS201M-C25 AC100 2CSR275040R2254

32 DS201M-B32 AC100 2CSR275040R2325 DS201M-C32 AC100 2CSR275040R2324

40 DS201M-B40 AC100 2CSR275040R2405 DS201M-C40 AC100 2CSR275040R2404

6

300

DS201M-B6 AC300 2CSR275040R3065 DS201M-C6 AC300 2CSR275040R3064

10 DS201M-B10 AC300 2CSR275040R3105 DS201M-C10 AC300 2CSR275040R3104

13 DS201M-B13 AC300 2CSR275040R3135 DS201M-C13 AC300 2CSR275040R3134

16 DS201M-B16 AC300 2CSR275040R3165 DS201M-C16 AC300 2CSR275040R3164

20 DS201M-B20 AC300 2CSR275040R3205 DS201M-C20 AC300 2CSR275040R3204

25 DS201M-B25 AC300 2CSR275040R3255 DS201M-C25 AC300 2CSR275040R3254

32 DS201M-B32 AC300 2CSR275040R3325 DS201M-C32 AC300 2CSR275040R3324

40 DS201M-B40 AC300 2CSR275040R3405 DS201M-C40 ACC300 2CSR275040R3404

í

íñìè ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ÎÝÞÑ­ ÜÍîðï Ó ­»®·»­ ïðððð ßÝ © ¬§°»ô Ý ½¸¿®¿½¬»®·­¬·½

ÜÍîðï Ó ßÝ ¬§°»ô Ý ½¸¿®¿½¬»®·­¬·½

Ú«²½¬·±²æ °®±¬»½¬·±² ±º »²¼ «­»® ­·²¹´»ó°¸¿­» ½·®½«·¬­ ¿¹¿·²­¬ ±ª»®´±¿¼ ¿²¼ ­¸±®¬ó½·®½«·¬ ½«®ó

®»²¬­å °®±¬»½¬·±² ¿¹¿·²­¬ ¬¸» »ºº»½¬­ ±º ­·²«­±·¼¿´ ¿´¬»®²¿¬·²¹ »¿®¬¸ º¿«´¬ ½«®®»²¬­å °®±¬»½¬·±²

ß°°´·½¿¬·±²æ ®»­·¼»²¬·¿´ô ½±³³»®½·¿´ô ·²¼«­¬®·¿´ò

ͬ¿²¼¿®¼æ ×ÛÝñÛÒ êïððç

×½²ãïð µß

Ò«³¾»®±º °±´»­

כּ¼®»­·¼«¿´½«®®»²¬× ² ³ß

כּ¼½«®®»²¬

ײ ß

Þ¾²èðïîëìî

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ïõÒ íð ê çççéðê ÜÍîðï Ó Ýê ßÝíð îÝÍÎîéëðìðÎïðêì ðòîìð ë

ïð çççèðë ÜÍîðï Ó Ýïð ßÝíð îÝÍÎîéëðìðÎïïðì ðòîìð ë

ïí ççççðì ÜÍîðï Ó Ýïí ßÝíð îÝÍÎîéëðìðÎïïíì ðòîìð ë

ïê ïðëêëé ÜÍîðï Ó Ýïê ßÝíð îÝÍÎîéëðìðÎïïêì ðòîìð ë

îð ïðëéëê ÜÍîðï Ó Ýîð ßÝíð îÝÍÎîéëðìðÎïîðì ðòîìð ë

îë ïðëèëë ÜÍîðï Ó Ýîë ßÝíð îÝÍÎîéëðìðÎïîëì ðòîìð ë

íî ïðëçëì ÜÍîðï Ó Ýíî ßÝíð îÝÍÎîéëðìðÎïíîì ðòîìð ë

ìð ïðêðëð ÜÍîðï Ó Ýìð ßÝíð îÝÍÎîéëðìðÎïìðì ðòîìð ë

ïðð ê ïðêçëï ÜÍîðï Ó Ýê ßÝïðð îÝÍÎîéëðìðÎîðêì ðòîìð ë

ïð ïðéðëé ÜÍîðï Ó Ýïð ßÝïðð îÝÍÎîéëðìðÎîïðì ðòîìð ë

ïí ïðéïëê ÜÍîðï Ó Ýïí ßÝïðð îÝÍÎîéëðìðÎîïíì ðòîìð ë

ïê ïðéîëë ÜÍîðï Ó Ýïê ßÝïðð îÝÍÎîéëðìðÎîïêì ðòîìð ë

îð ïðéíëì ÜÍîðï Ó Ýîð ßÝïðð îÝÍÎîéëðìðÎîîðì ðòîìð ë

îë ïðéìëí ÜÍîðï Ó Ýîë ßÝïðð îÝÍÎîéëðìðÎîîëì ðòîìð ë

íî ïðéëëî ÜÍîðï Ó Ýíî ßÝïðð îÝÍÎîéëðìðÎîíîì ðòîìð ë

ìð ïðéêëï ÜÍîðï Ó Ýìð ßÝïðð îÝÍÎîéëðìðÎîìðì ðòîìð ë

íðð ê ïðèëëç ÜÍîðï Ó Ýê ßÝíðð îÝÍÎîéëðìðÎíðêì ðòîìð ë

ïð ïðèêëè ÜÍîðï Ó Ýïð ßÝíðð îÝÍÎîéëðìðÎíïðì ðòîìð ë

ïí ïðèéëé ÜÍîðï Ó Ýïí ßÝíðð îÝÍÎîéëðìðÎíïíì ðòîìð ë

ïê ïðèèëê ÜÍîðï Ó Ýïê ßÝíðð îÝÍÎîéëðìðÎíïêì ðòîìð ë

îð ïðèçëë ÜÍîðï Ó Ýîð ßÝíðð îÝÍÎîéëðìðÎíîðì ðòîìð ë

îë ïðçðëï ÜÍîðï Ó Ýîë ßÝíðð îÝÍÎîéëðìðÎíîëì ðòîìð ë

íî ïðçïëð ÜÍîðï Ó Ýíî ßÝíðð îÝÍÎîéëðìðÎííîì ðòîìð ë

ìð ïðçîëç ÜÍîðï Ó Ýìð ßÝíðð îÝÍÎîéëðìðÎíìðì ðòîìð ëî

ÝÍ

Ýì

ðð

ðð

ëÚ

ðî

ðî

ÜÍîðï Ó

ɸ»®» ¬± º·²¼ ³±®»æɱ®´¼©·¼» Ó¿®µ­ ¿²¼ ß°°®±ª¿´­ °òïïñçîÌ»½¸²·½¿´ ¹«·¼» ±º ÎÝÜ­ ø½±¼» îÝÍÝìîðððìÞðîðï÷

Ú®»¯«»²¬´§ ¿­µ»¼ ¯«»­¬·±² ó ÚßÏæß ½±³°´»¬» ´·­¬ ±º ¿²­©»®­ ·­ ¿ª¿·´¿¾´» ·² ¬¸» ÎÝÜ­ ÚßÏ ¼±½«³»²¬ ø½±¼» îÝÍÝìîðððëÞðîðï÷

Ó¿§¾» §±« ¿®» ¿´­± ·²¬»®»­¬»¼ ·²æß«¨·´·¿®§ Û´»³»²¬­ º±® ÎÝÜ­ °òìñì ß½½»­­±®·»­ º±® ÎÝÜ­ °òìñïêÞ«­¾¿® ͧ­¬»³­ °òìñîï

Page 33: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

32 Line Protection Equipment 0115 ABB Low Voltage 33 Line Protection Equipment 0115 ABB Low Voltage

DS271 AC type 10kA Product Hierarchy 2500001

Type B Type CRated Current Tripping mA Part No Order Code Part No Order Code6

10mA

DS271 AC-B6/0.01 2CSR175092R0065 DS271 AC-C6/0.01 2CSR175092R0064

10 DS271 AC-B10/0.01 2CSR175092R0105 DS271 AC-C10/0.01 2CSR175092R0104

16 DS271 AC-B16/0.01 2CSR175092R0165 DS271 AC-C16/0.01 2CSR175092R0164

20 DS271 AC-B20/0.01 2CSR175092R0205 DS271 AC-C20/0.01 2CSR175092R0204

25 DS271 AC-B25/0.01 2CSR175092R0255 DS271 AC-C25/0.01 2CSR175092R0254

32 DS271 AC-B32/0.01 2CSR175092R0325 DS271 AC-C32/0.01 2CSR175092R0324

6

30mA

DS271 AC-B6/0.03 2CSR175092R1065 DS271 AC-C6/0.03 2CSR175092R1064

10 DS271 AC-B10/0.03 2CSR175092R1105 DS271 AC-C10/0.03 2CSR175092R1104

16 DS271 AC-B16/0.03 2CSR175092R1165 DS271 AC-C16/0.03 2CSR175092R1164

20 DS271 AC-B20/0.03 2CSR175092R1205 DS271 AC-C20/0.03 2CSR175092R1204

25 DS271 AC-B25/0.03 2CSR175092R1255 DS271 AC-C25/0.03 2CSR175092R1254

32 DS271 AC-B32/0.03 2CSR175092R1325 DS271 AC-C32/0.03 2CSR175092R1324

40 - - DS271 AC-C40/0.03 2CSR175092R1404

6

100mA

- - DS271 AC-C6/0.1 2CSR175092R2064

10 - - DS271 AC-C10/0.1 2CSR175092R2104

16 - - DS271 AC-C16/0.1 2CSR175092R2164

20 - - DS271 AC-C20/0.1 2CSR175092R2204

25 - - DS271 AC-C25/0.1 2CSR175092R2254

32 - - DS271 AC-C32/0.1 2CSR175092R2324

6

300mA

- - DS271 AC-C6/00.3 2CSR175092R3064

10 - - DS271 AC-C10/00.3 2CSR175092R3104

16 - - DS271 AC-C16/00.3 2CSR175092R3164

20 - - DS271 AC-C20/00.3 2CSR175092R3204

25 - - DS271 AC-C25/00.3 2CSR175092R3254

32 - - DS271 AC-C32/00.3 2CSR175092R3324

40 - - DS271 AC-C40/00.3 2CSR175092R3404

DS271 A type 10kA Product Hierarchy 2500001

Type B Type CRated Current Tripping mA Part No Order Code Part No Order Code6

10mA

DS271 A-B6/0.01 2CSR175192R0065 DS271 A-C6/0.01 2CSR175192R0064

10 DS271 A-B10/0.01 2CSR175192R0105 DS271 A-C10/0.01 2CSR175192R0104

16 DS271 A-B16/0.01 2CSR175192R0165 DS271 A-C16/0.01 2CSR175192R0164

20 DS271 A-B20/0.01 2CSR175192R0205 DS271 A-C20/0.01 2CSR175192R0204

25 DS271 A-B25/0.01 2CSR175192R0255 DS271 A-C25/0.01 2CSR175192R0254

32 DS271 A-B32/0.01 2CSR175192R0325 DS271 A-C32/0.01 2CSR175192R0324

6

30mA

DS271 A-B6/0.03 2CSR175192R1065 DS271 A-C6/0.03 2CSR175192R1064

10 DS271 A-B10/0.03 2CSR175192R1105 DS271 A-C10/0.03 2CSR175192R1104

16 DS271 A-B16/0.03 2CSR175192R1165 DS271 A-C16/0.03 2CSR175192R1164

20 DS271 A-B20/0.03 2CSR175192R1205 DS271 A-C20/0.03 2CSR175192R1204

25 DS271 A-B25/0.03 2CSR175192R1255 DS271 A-C25/0.03 2CSR175192R1254

32 DS271 A-B32/0.03 2CSR175192R1325 DS271 A-C32/0.03 2CSR175192R1324

6

100mA

- - DS271 A-C6/0.1 2CSR175192R2064

10 - - DS271 A-C10/0.1 2CSR175192R2104

16 - - DS271 A-C16/0.1 2CSR175192R2164

20 - - DS271 A-C20/0.1 2CSR175192R2204

25 - - DS271 A-C25/0.1 2CSR175192R2254

32 - - DS271 A-C32/0.1 2CSR175192R2324

40 - - - -

6

300mA

- - DS271 A-C6/00.3 2CSR175192R3064

10 - - DS271 A-C10/00.3 2CSR175192R3104

16 - - DS271 A-C16/00.3 2CSR175192R3164

20 - - DS271 A-C20/00.3 2CSR175192R3204

25 - - DS271 A-C25/00.3 2CSR175192R3254

32 - - DS271 A-C32/00.3 2CSR175192R3324

40 - - DS271 A-C32/00.3 2CSR175192R3404

3/38

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

DS 271 AC type, B and C characteristicsFunction: protection against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts (IΔn=30 mA); command and isolation of resistive and inductive loads.

Application: residential, commercial, industrial.

Standard: IEC/EN 61009 and BSEN61009-2-2

Icn=10 kA

Rated residual current Rated current In A Type B Price Type C Price

30 6 DS271 AC-B6/0.03 55.82 DS271 AC-C6/0.03 55.82

10 DS271 AC-B10/0.03 55.82 DS271 AC-C10/0.03 55.82

16 DS271 AC-B16/0.03 55.82 DS271 AC-C16/0.03 55.82

20 DS271 AC-B20/0.03 55.82 DS271 AC-C20/0.03 55.82

25 DS271 AC-B25/0.03 55.82 DS271 AC-C25/0.03 55.82

32 DS271 AC-B32/0.03 55.82 DS271 AC-C32/0.03 55.82

100 6 - - DS271 AC-C6/0.1 55.82

10 - - DS271 AC-C10/0.1 55.82

16 - - DS271 AC-C16/0.1 55.82

20 - - DS271 AC-C20/0.1 55.82

25 - - DS271 AC-C25/0.1 55.82

32 - - DS271 AC-C32/0.1 55.82

System ProMRCBO’s DS 271 series B & C characteristics - 10kA

B&C

ABB SF Section 3.5.indd 3/38 15/2/07 11:36:28 am

System ProM compactDS271 AC & A B, C RCBOs

Page 34: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

34 Line Protection Equipment 0115 ABB Low Voltage 35 Line Protection Equipment 0115 ABB Low Voltage

ì

ìñì ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ Ú îðð

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ «­»¼

¿­ ¿«¨·´·¿®§ ½±²¬¿½¬

ÍîÝóÍñØêÎ

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

ÑΠѪ»®ª±´¬¿¹» ®»´»¿­» ÍîÝóÑÊÐ

ßÎ ß«¬± ®»½´±­·²¹ «²·¬ ÚîÝóßÎ×

ÓÑÜóÚ Ó±¬±® ±°»®¿¬·²¹ ¼»ª·½» ÚîÝóÝÓ

ÍÌóÚ Í¸«²¬ ¬®·° º±® Ú îðð ÎÝÝÞ ÚîÝóß

ݱ³¾·²¿¬·±² ±º ¸±³» ¿«¬±³¿¬·½ ®»­»¬¬·²¹ «²·¬ ©·¬¸ Ú îðð

ßÎØ Ø±³» ¿«¬±³¿¬·½ ®»­»¬¬·²¹ «²·¬ ÚîÝóßÎØ

ö Ú îðî íð ³ß ±® ïðð ³ß ø¼»°»²¼·²¹ ±² ßÎØ ³±¼»´÷ô ³¿¨ êí ß

Ú îðð

ر®ÍñØ

Ø

ÍñØøØ÷

ßÎñÓÑÜóÚ

ÍÌóÚ±®Ëα®ÑÎ

ر®ÍñØ

ÍñØøØ÷

Ø

Ú îðð ö ßÎØ

îÝ

ÍÝ

ìð

ðð

ïï

Úð

îð

î

îÝ

ÍÝ

ìð

ðð

ïð

Úð

îð

î

ß«¨·´·¿®§ »´»³»²¬­ ¿²¼ ¿½½»­­±®·»­ º±® ÓÝÞ­ ¿²¼ ÎÝÜ­Í»´»½¬·±² ¬¿¾´»­

ì

ìñì ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ Ú îðð

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ «­»¼

¿­ ¿«¨·´·¿®§ ½±²¬¿½¬

ÍîÝóÍñØêÎ

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

ÑΠѪ»®ª±´¬¿¹» ®»´»¿­» ÍîÝóÑÊÐ

ßÎ ß«¬± ®»½´±­·²¹ «²·¬ ÚîÝóßÎ×

ÓÑÜóÚ Ó±¬±® ±°»®¿¬·²¹ ¼»ª·½» ÚîÝóÝÓ

ÍÌóÚ Í¸«²¬ ¬®·° º±® Ú îðð ÎÝÝÞ ÚîÝóß

ݱ³¾·²¿¬·±² ±º ¸±³» ¿«¬±³¿¬·½ ®»­»¬¬·²¹ «²·¬ ©·¬¸ Ú îðð

ßÎØ Ø±³» ¿«¬±³¿¬·½ ®»­»¬¬·²¹ «²·¬ ÚîÝóßÎØ

ö Ú îðî íð ³ß ±® ïðð ³ß ø¼»°»²¼·²¹ ±² ßÎØ ³±¼»´÷ô ³¿¨ êí ß

Ú îðð

ر®ÍñØ

Ø

ÍñØøØ÷

ßÎñÓÑÜóÚ

ÍÌóÚ±®Ëα®ÑÎ

ر®ÍñØ

ÍñØøØ÷

Ø

Ú îðð ö ßÎØ

îÝ

ÍÝ

ìð

ðð

ïï

Úð

îð

î

îÝ

ÍÝ

ìð

ðð

ïð

Úð

îð

î

ß«¨·´·¿®§ »´»³»²¬­ ¿²¼ ¿½½»­­±®·»­ º±® ÓÝÞ­ ¿²¼ ÎÝÜ­Í»´»½¬·±² ¬¿¾´»­

ì

ìñî ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ß«¨·´·¿®§ »´»³»²¬­ ¿²¼ ¿½½»­­±®·»­ º±® ÓÝÞ­ ¿²¼ ÎÝÜ­Í»´»½¬·±² ¬¿¾´»­

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ Í îððô ÜÜß îðð õ Í îðð ±® ÜÍ îðð

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ØóÎ ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêóòòòÎ

ÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ «­»¼ ¿­ ¿«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍÌ Í¸«²¬ ¬®·° º±® Í îðð ÓÝÞ ÍîÝóßòòò

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

ÑΠѪ»®ª±´¬¿¹» ®»´»¿­» ÍîÝóÑÊÐ

ØóÔ ß«¨·´·¿®§ ½±²¬¿½¬ º±® Í îðð ÓÝÞ­ ¬± ¾» ³±«²¬»¼ ±² ¬¸» ´»º¬ ÍîÝóØòòòÔ

ØóÞÚ ß«¨·´·¿®§ ½±²¬¿½¬ º±® ÓÝÞ­ ¾±¬¬±³ º·¬¬·²¹ øï º±® »¿½¸ °±´» ±º ÓÝÞ÷ ÍîÝóØðïñÍîÝóØïð

ÞÐ Ó»½¸¿²·½¿´ ¬®·°°·²¹ ¼»ª·½» ÍîÝóÞÐ

ÒÌ Í©·¬½¸»¼ ²»«¬®¿´ ÍîÝóÒ¬

ײ ½¿­» ±º «­·²¹ ®±¬¿®§ ±°»®¿¬·²¹ ³»½¸¿²·­³ ÍîÝóÜØ ø±²´§ ®·¹¸¬ ­·¼» ³±«²¬¿¾´»÷ ¬¸» ¿«¨·´·¿®§ ¼»ª·½»­ ´»º¬ ­·¼» ¿²¼ ¾±¬¬±³ ¬¬·²¹ ¿«¨·´·¿®§ ½±²¬¿½¬ ½±«´¼ ¾» «­»¼ò

îÝ

ÜÝ

ðç

îð

ðî

Úð

îï

î

System ProM compactAccessories overview

Combination of auxiliary elements with S200, DDA200 + S200 or DS200

Combination of home automatic resetting unit with F200

Combination of auxiliary elements with F200

ì

ìñî ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ß«¨·´·¿®§ »´»³»²¬­ ¿²¼ ¿½½»­­±®·»­ º±® ÓÝÞ­ ¿²¼ ÎÝÜ­Í»´»½¬·±² ¬¿¾´»­

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ Í îððô ÜÜß îðð õ Í îðð ±® ÜÍ îðð

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ØóÎ ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêóòòòÎ

ÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ «­»¼ ¿­ ¿«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍÌ Í¸«²¬ ¬®·° º±® Í îðð ÓÝÞ ÍîÝóßòòò

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

ÑΠѪ»®ª±´¬¿¹» ®»´»¿­» ÍîÝóÑÊÐ

ØóÔ ß«¨·´·¿®§ ½±²¬¿½¬ º±® Í îðð ÓÝÞ­ ¬± ¾» ³±«²¬»¼ ±² ¬¸» ´»º¬ ÍîÝóØòòòÔ

ØóÞÚ ß«¨·´·¿®§ ½±²¬¿½¬ º±® ÓÝÞ­ ¾±¬¬±³ º·¬¬·²¹ øï º±® »¿½¸ °±´» ±º ÓÝÞ÷ ÍîÝóØðïñÍîÝóØïð

ÞÐ Ó»½¸¿²·½¿´ ¬®·°°·²¹ ¼»ª·½» ÍîÝóÞÐ

ÒÌ Í©·¬½¸»¼ ²»«¬®¿´ ÍîÝóÒ¬

ײ ½¿­» ±º «­·²¹ ®±¬¿®§ ±°»®¿¬·²¹ ³»½¸¿²·­³ ÍîÝóÜØ ø±²´§ ®·¹¸¬ ­·¼» ³±«²¬¿¾´»÷ ¬¸» ¿«¨·´·¿®§ ¼»ª·½»­ ´»º¬ ­·¼» ¿²¼ ¾±¬¬±³ ¬¬·²¹ ¿«¨·´·¿®§ ½±²¬¿½¬ ½±«´¼ ¾» «­»¼ò

îÝ

ÜÝ

ðç

îð

ðî

Úð

îï

î

H Auxiliary contact SC2-H6R

S/H Signal/ Auxiliary contact SC2-S/H6R

S/H (H) Signal/ Auxiliary contact used as auxiliary contact SC2-S/H6R

UR Undervoltage release S2C-UA

OR Over voltage release S2C-OVP

AR Auto reclosing unit FC2-ARI

MOD-F Motor operating device F2C-CM

ST-F Shunt trip for F200 RCCB F2C-A

ARH Home automatic resetting unit FC2-ARH

H Auxiliary contact SC2-H6R

H-R Auxiliary contact SC2-H6-....R

S/H Signal/ Auxiliary contact SC2-S/H6R

S/H (H) Signal/ Auxiliary contact used as auxiliary contact SC2-S/H6R

ST Shunt trip for S200 MCB S2C-A

OR Over voltage release S2C-OVP

H-L Auxiliary contact for S200 MCBs mounted on left sde SC2-H...L

H-BF Auxiliary contact for S200 MCBs Bottom fitting (i for each pole of MCB) SC2-H01/SC2-H10

BP Mechanical tripping device SC2-BP

NT Switched neutral SC2-Nt

Page 35: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

34 Line Protection Equipment 0115 ABB Low Voltage 35 Line Protection Equipment 0115 ABB Low Voltage

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñí

ÍÒ îðï

Ø ØÍ ÍÌóÚñËÎ

ÍñØ ÍñØøØ÷

×ØÍñØ ÍñØ

øØ÷

Ø Ø

ݱ³¾·²¿¬·±² ±º Í îðð ©·¬¸ ³±¬±® ±°»®¿¬·²¹ ¼»ª·½»

ÍÌ Í¸«²¬ ¬®·° º±® Í îðð ÓÝÞ Í ÍîÝóßòòò

ÓÑÜóÍö Ó±¬±® ±°»®¿¬·²¹ ¼»ª·½» ÍîÝóÝÓòòò

ö ·² ½¿­» ±º «­·²¹ Í îðð ½±«°´»¼ ©·¬¸ ÜÜß îððô ÓÑÜóÍ ¼±»­²¬ ±°»®¿¬» ·² ½¿­» ±º

»¿®¬¸ó´»¿µ¿¹» º¿«´¬

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ ÍÒ îðï

×Ø Ý±«°´·²¹ ·²¬»® º¿½»ñ ¿«¨·´ ·¿®§

½±²¬¿½¬

ÍÒîðïó×Ø

Í Í·¹²¿´ ½±²¬¿½¬ ÍÒîðïóÍ

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ÍñØ Í·¹²¿´ñ¿«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñ¿«¨·´·¿®§ ½±²¬¿½¬ «­»¼

¿­ ¿«¨·´·¿®§ ½±²¬¿½¬

ÍîÝóÍñØêÎ

ÍÌóÚ Í¸«²¬ ¬®·° ±º Úîðð ÎÝÜ ÚîÝóß

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

Í îðð

ÍÌ ÓÑÜóÍ

ÓÑÜóÍ

îÝ

ÍÝ

ìð

ðð

ïï

Úð

îð

î

îÝ

ÍÝ

ìð

ðð

ïï

Úð

îð

î

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñí

ÍÒ îðï

Ø ØÍ ÍÌóÚñËÎ

ÍñØ ÍñØøØ÷

×ØÍñØ ÍñØ

øØ÷

Ø Ø

ݱ³¾·²¿¬·±² ±º Í îðð ©·¬¸ ³±¬±® ±°»®¿¬·²¹ ¼»ª·½»

ÍÌ Í¸«²¬ ¬®·° º±® Í îðð ÓÝÞ Í ÍîÝóßòòò

ÓÑÜóÍö Ó±¬±® ±°»®¿¬·²¹ ¼»ª·½» ÍîÝóÝÓòòò

ö ·² ½¿­» ±º «­·²¹ Í îðð ½±«°´»¼ ©·¬¸ ÜÜß îððô ÓÑÜóÍ ¼±»­²¬ ±°»®¿¬» ·² ½¿­» ±º

»¿®¬¸ó´»¿µ¿¹» º¿«´¬

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ ÍÒ îðï

×Ø Ý±«°´·²¹ ·²¬»® º¿½»ñ ¿«¨·´ ·¿®§

½±²¬¿½¬

ÍÒîðïó×Ø

Í Í·¹²¿´ ½±²¬¿½¬ ÍÒîðïóÍ

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ÍñØ Í·¹²¿´ñ¿«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñ¿«¨·´·¿®§ ½±²¬¿½¬ «­»¼

¿­ ¿«¨·´·¿®§ ½±²¬¿½¬

ÍîÝóÍñØêÎ

ÍÌóÚ Í¸«²¬ ¬®·° ±º Úîðð ÎÝÜ ÚîÝóß

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

Í îðð

ÍÌ ÓÑÜóÍ

ÓÑÜóÍ

îÝ

ÍÝ

ìð

ðð

ïï

Úð

îð

î

îÝ

ÍÝ

ìð

ðð

ïï

Úð

îð

î

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñë

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ ÜÍîðïô ÜÍîðîÝ

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ «­»¼

¿­ ¿«¨·´·¿®§ ½±²¬¿½¬

ÍîÝóÍñØêÎ

ÍÌóÚ Í¸«²¬ ¬®·° º±® Ú îðð ÎÝÝÞ ÚîÝóß

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

ÑΠѪ»®ª±´¬¿¹» ®»´»¿­» ÍîÝóÑÊÐ

ÓÑÜóÜÍ Ó±¬±® ±°»®¿¬·²¹ ¼»ª·½» ÜÍîÝóÝÓ

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ Ú îðì ïîë ßô Þ

¬§°»ô ÐÊ Þ

ÚîóïîëßóÞóÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬

Ú îðì ïîë ßÚ îðì Þ ¬§°»Ú îðì ÐÊ Þ

Úî ïîë ß ÍñØ

ÜÍîðïÜÍîðîÝ

õ ÍÌóÚ õ Ø õ Ø

õ ÓÑÜóÜÍ

õ ËÎ õ Ø õ Øõ ÑÎ õ Ø õ Ø

õ ÍñØ õ Ø

õ ÍñØ õ ÍñØ øØ÷

õ Ø õ Ø

õ ÍÌóÚ õ ÍñØ õ ÍñØ øØ÷

õ ËÎ õ ÍñØ õ ÍñØ øØ÷õ ÑÎ õ ÍñØ õ ÍñØ øØ÷

îÝ

ÍÝ

ìð

ðð

ïð

Úð

îð

î

îÝ

ÍÝ

ìð

ðð

ïî

Úð

îð

î

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñë

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ ÜÍîðïô ÜÍîðîÝ

Ø ß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóØêÎ

ÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ ÍîÝóÍñØêÎ

ÍñØ øØ÷ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬ «­»¼

¿­ ¿«¨·´·¿®§ ½±²¬¿½¬

ÍîÝóÍñØêÎ

ÍÌóÚ Í¸«²¬ ¬®·° º±® Ú îðð ÎÝÝÞ ÚîÝóß

ËΠ˲¼»®ª±´¬¿¹» ®»´»¿­» ÍîÝóËß

ÑΠѪ»®ª±´¬¿¹» ®»´»¿­» ÍîÝóÑÊÐ

ÓÑÜóÜÍ Ó±¬±® ±°»®¿¬·²¹ ¼»ª·½» ÜÍîÝóÝÓ

ݱ³¾·²¿¬·±² ±º ¿«¨·´·¿®§ »´»³»²¬­ ©·¬¸ Ú îðì ïîë ßô Þ

¬§°»ô ÐÊ Þ

ÚîóïîëßóÞóÍñØ Í·¹²¿´ñß«¨·´·¿®§ ½±²¬¿½¬

Ú îðì ïîë ßÚ îðì Þ ¬§°»Ú îðì ÐÊ Þ

Úî ïîë ß ÍñØ

ÜÍîðïÜÍîðîÝ

õ ÍÌóÚ õ Ø õ Ø

õ ÓÑÜóÜÍ

õ ËÎ õ Ø õ Øõ ÑÎ õ Ø õ Ø

õ ÍñØ õ Ø

õ ÍñØ õ ÍñØ øØ÷

õ Ø õ Ø

õ ÍÌóÚ õ ÍñØ õ ÍñØ øØ÷

õ ËÎ õ ÍñØ õ ÍñØ øØ÷õ ÑÎ õ ÍñØ õ ÍñØ øØ÷

îÝ

ÍÝ

ìð

ðð

ïð

Úð

îð

î

îÝ

ÍÝ

ìð

ðð

ïî

Úð

îð

îCombination of auxiliary elements with F204 125 Type A, PV B

Combination of S200 with motor operating device

Combination of auxiliary elements with DS201, DS202C

Combination of auxiliary elements with SN201

H Auxiliary contact SC2-H6R

S/H Signal/ Auxiliary contact SC2-S/H6R

S/H (H) Signal/ Auxiliary contact used as auxiliary contact SC2-S/H6R

ST-F Shunt trip for F200 RCCB F2C-A

UR Undervoltage release S2C-UA

OR Over voltage release S2C-OVP

MOD-DS Motor operating device DS2C-CM

F2-125A-B-S/H Signal/ Auxiliary contact

IH Coupling interface/auxiliary contact S201-1H

S Signal contact SN201-S

H Auxiliary contact SC2-H6R

S/H Signal/ Auxiliary contact SC2-S/H6R

S/H (H) Signal/ Auxiliary contact used as auxiliary contact SC2-S/H6R

ST-F Shunt trip for F200 RCCB F2C-A

UR Undervoltage release S2C-UA

MOD-S* Motor operating device SC2-CM

ST Shunt trip for S200 MCBs SC2-A...

System ProM compactAccessories overview

Page 36: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

36 Line Protection Equipment 0115 ABB Low Voltage 37 Line Protection Equipment 0115 ABB Low Voltage

H Auxiliary contact S2C-H6R

H-R Auxiliary contact S2C-H6-...R

S/H Signal/Auxiliary contact S2C-S/H6R

S/H (H) Signal/Auxiliary contact used as auxiliary contact S2C-S/H6R

ST Shunt trip S2C-A...

UR Undervoltage release S2C-UA

H Auxiliary contact S2C-H6RU

S Signal contact S2C-S/H6RU

ST Shunt trip S2C-A...U

Combination of auxiliary elements with S 200 PR Combination of auxiliary elements with SU 200 PR

System ProM compactAccessories overview

Page 37: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

36 Line Protection Equipment 0115 ABB Low Voltage 37 Line Protection Equipment 0115 ABB Low Voltage

Combination of auxiliary elements with SU 200 PR

H Auxiliary contact S2C-H6R

H-R Auxiliary contact S2C-H6-...R

S/H Signal/Auxiliary contact S2C-S/H6R

S/H (H) Signal/Auxiliary contact used as auxiliary contact S2C-S/H6R

NT Switched neutral S2C-Nt

MOD-S Motor operating device S2C-CM

OR Overvoltage release S2C-OVP

BP Mechanical tripping device S2C-BP

ST Shunt trip S2C-A...

UR Undervoltage release S2C-UA

Combination of auxiliary elements with SD 200

System ProM compactAccessories overview

Page 38: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

38 Line Protection Equipment 0115 ABB Low Voltage 39 Line Protection Equipment 0115 ABB Low Voltage

Signal/auxiliary contacts Function S2C-S/H6R: choice through a selector between indication of the position of the device’s contacts and signalling of the fault (overcurrent/short-circuit for MCBs and RCBOs; earth fault for RCCBs and RCBOs). Suitable for MCBs S 200 series, RCCBs F 200 series, RCBOs DS201, DS202C, DS 200 and SD 200 switch disconnectors series.Function S2C-H6R: indication of the position of the device’s contacts. Suitable for MCBs S200 series. To be mounted on the left side of the MCBs thanks to the special pin. Suitable for SD 200 switch disconnectors series. They are not suitable to be mounted together with RCD-block DDA200.Function S2C-H6-xxR: indication of the position of the MCB contact. Mounted on the right side. Suitable for SD 200 switch disconnectors series. They are not suitable to be mounted together with other right side mounted auxiliary contacts.

Description Part NumberProduct Hierarchy

2400002 Order Code

Signal contact/ auxiliary switch 1CO S2C-S/H6R 2CDS200922R0001

Auxiliary contact 1CO S2C-H6R 2CDS200912R0001

Auxiliary contact 1NO/1NC S2C-H6-11R 2CDS200946R0001

Auxiliary contact 2NO S2C-H6-20R 2CDS200946R0002

Auxiliary contact 2NC S2C-H6-02R 2CDS200946R0003

Auxiliary contacts mounting on the left sideAuxiliary contact 1 NO/1NC S2C-H11L 2CDS200936R0001

Auxiliary contact 2 NO S2C-H20L 2CDS200936R0002

Auxiliary contact 2 NC S2C-H02L 2CDS200936R0003

Bottom-fitting auxiliary contacts for S 200, S 200 M, S 200 P, S 200 S, SD 2001 NC S 2C-H01 2CDS 200 970 R0001

1 NO S 2C-H10 2CDS 200 970 R0002

Auxiliary contact bridge for bottom-fitting auxiliary contactsWire jumper for integrated auxiliary contact (MCB S 200 H or auxiliary contacts S2C-H01/S2C-H10 for series connections (HKB) or parallel connections (HKB1)

1/2 mod. HKB GH V036 0504 R0100

1 mod. HKB 1 GH V036 0504 R0101

Signal contact for SN201 MCBs

Function: indication of the device contact positions only after the automatic release of the MCBs due to overcurrent.

Signal contact 1CO SN201-S 2CSS200924R0001

Auxiliary contact / interface module for SN201 MCBs

Function: indication of the device contact positions. The auxiliary contact can be used as an interface module between SN201 and other compact auxiliary elements.

Interface module/Aux. Contact 1CO SN201-IH 2CSS200923R0001

Auxiliary/Signal contact for F 200 125A and F 200 B Function: choice through a selector between indication of the position of the device’s contacts and signalling of the earth fault. Suitable for RCCBs F 200 125A and F 200 B series

Auxiliary/Signal contact 1CO+1NC F2-125A-B-S/H 2CSF200922R0001

S2C-S/H6R

S2C-H6-...

Auxiliary elements for MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch Disconnectors SD 200 series

SN201-S

SN201-IH

Page 39: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

38 Line Protection Equipment 0115 ABB Low Voltage 39 Line Protection Equipment 0115 ABB Low Voltage

Shunt tripsFunction: remote opening of the device when a voltage is applied. Suitable for MCBs S 200 series, RCBOs DS 200 series, SD 200 switch disconnectors series.

Rated voltage Part NumberProduct Hierarchy

2400002 Order Code

AC/DC 12…60 V S2C-A1 2CDS200909R0001

AC 110…415 V/DC110…250 V S2C-A2 2CDS200909R0002

Function: remote opening of the device when a voltage is applied. Suitable for RCCBs F 200 series and RCBOs DS201 and DS202C. It can be used with MCBs SN201 series by means of SN201-IH interface module.

AC/DC 12...60V F2C-A1 2CSS200933R0011

AC 110...415V / DC 110...250V F2C-A2 2CSS200933R0012

Undervoltage releases Function: protection of the load in the event of a voltage drop (between 70% and 35% of its rated value); positive safety (device’s tripping when the voltage is disconnected) emergency stop by means of a button. Suitable for MCBs S 200 series, RCCBs F200 series and RCBOs DS201, DS202C, DS 200 series, SD 200 switch disconnectors series. It can be used with MCBs SN201 series by means of SN201-IH interface module.

12VDC S2C-UA 12 DC 2CSS200911R0001

24VAC S2C-UA 24 AC 2CSS200911R0002

24VDC S2C-UA 24 DC 2CSS200911R0007

48VAC S2C-UA 48 AC 2CSS200911R0003

48VDC S2C-UA 48 DC 2CSS200911R0008

110VAC S2C-UA 110 AC 2CSS200911R0004

110VDC S2C-UA 110 DC 2CSS200911R0009

230VAC S2C-UA 230 AC 2CSS200911R0005

230VDC S2C-UA 230 DC 2CSS200911R0010

400VAC S2C-UA 400 AC 2CSS200911R0006

Overvoltage releases Function: monitoring voltage between the neutral and phase; when an overvoltage reaches the threshold value, the OVP device causes the tripping of the associated MCB or RCCB. Suitable for MCBs of the S200 series up to 63 A, and RCCBs of the F200 series up to 100 A and RCBOs DS201 and DS202C series. Suitable for SD 200 switch disconnectors series.

Overvoltage release (max tripping voltage AC: 275V) S2C-OVP1 2CSS200910R0005

Overvoltage release (max tripping voltage AC: 290V) S2C-OVP2 2CSS200993R0005

Hand operated neutralThe hand operated neutral has to be mounted to the left side of the MCB and be snaped on the DIN rail. It is used for measuring duties where the neutral conductor must be in the open position. Due to the special design of the handle - when switching ON the MCB – the neutral will make before the MCB is closed. Suitable for SD 200 switch disconnectors series.The S2C - Nt is not to switch with a tool (screw driver).

Max 40A S2C-Nt 2CDS200918R0001

Mechanical tripping deviceFunction: it causes the automatic tripping of the circuit-breakers which it is associated to, when the panel or the door of the electrical switchboard are opened or removed. Suitable for MCBs S 200 series (on both sides of the devices) and for DS 200 (only on the right side, because on the left side there’s RCD-block DDA 200). Suitable for SD 200 switch disconnectors series.

Mechanical tripping device S2C-BP 2CSS200998R0001

Plug-in baseFunction: it is possible to transform a standard circuit-breaker of the S 200 and F 200 range in a plug-in device which can be pulled out of the cir-cuit where it is installed in one operation. Suitable for MCBs S 200 series and for RCCBs F 200 series up to 63 A and RCBOs DS201 and DS202C.

Plug-in base S2C-EST 2CSS200999R0001

Auxiliary elements for MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch Disconnectors SD 200 series

S2C-A

F2C-A

S2C-UA

S 2C-EST

S 2C-BP

S2C-OVP

S2C-Nt

Page 40: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

40 Line Protection Equipment 0115 ABB Low Voltage 41 Line Protection Equipment 0115 ABB Low Voltage

Motor operating devicesFunction: S2C-CM, F2C-CM and DS2C-CM allow the remote control (opening or closing) of the coupled device. Suitable for S200 MCBs up to 63 A, F 200 RCCBs up to 100 A and RCBOs DS201 and DS202C.

Description Part NumberProduct Hierarchy

2400002 Order Code

Motor operating device for 1P S200 MCBs S2C-CM1 2CSS201997R0013

Motor operating device for 2P and 3P S200 MCBs S2C-CM2/3 2CSS203997R0013

Motor operating device for 4P S200 MCBs S2C-CM4 2CSS204997R0013

Motor operating device for 2P and 4P F200 RCCBs F2C-CM 2CSF200997R0013

Motor operating device for 1P+N and 2P DS201, DS202C RCBOs DS2C-CM 2CSR201997R0013

Auto-reclosing unitsFunction: F2C-ARI and F2C-ARI30 allow the auto-reclosing of the coupled device in case of unwanted tripping. Suitable for F 200 RCCBs up to 100 A.

Auto-reclosing unit for 2P and 4P F200 RCCBs F2C-ARI 2CSF200996R0013

Auto-reclosing unit for 2P and 4P F200 RCCBs (30”) F2C-ARI30 2CSF200995R0013

Home automatic resetting unit (for domestic and similar applications)

Function: it recloses the associated residual current device, only after having checked that there are no effective faults in the system protected by the RCCB. Suitable for 2-pole RCCB series with 30 mA or 100 mA sensitivities, max 63 A

Home automatic resetting unit (30 mA) F2C-ARH 2CSF200992R0005

Home automatic resetting unit (100 mA) F2C-ARH100 2CSF200990R0005

Motor operating and autoreclosing devices for MCBs, RCDs and Switch Disconnectors

S2C-CM

F2C-ARH

Page 41: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

40 Line Protection Equipment 0115 ABB Low Voltage 41 Line Protection Equipment 0115 ABB Low Voltage

Busbar systems Selection table

Shor t descriptionABB busbar systems enable the safe and economic cross connection of MCBs, RCCBs and RCBOs.

For a correct busbar selection the following points need to be considered: – MCB terminal type (Twin terminal or cage terminal) – Number of poles (1, 2, 3, 4, 1+N or 3+N) – Device type (MCB, RCCB or RCBO) – Combinations (e.g. RCCB + MCB or RCCB 3+N + RCCB 1+N) – Use of side mounted auxiliary elements on MCB *) – Busbar diameter (for current carrying capacity calculation)

– Number of modules (choice of standard busbar or busbar for cutting)

Coding of PS busbars

Phases1 phase 12 phases 23 phases 3 4 phases 4

1

Number of pins

2 3

Diameter10 mm2 - -6 mm2 6 -16 mm2 1 630 mm2 3 0

4 5

ApplicationCross connection of RCCB and MCB (4th pin removed for RCCB 3+N) F IUse of neutral conductor (phase sequence e.g. L1-N-L2-N-L3-N-L1...) NSpace for 1 side mounted auxiliary contact HSpace for 2 side mounted auxiliary contacts H 2Pins for breaking off ACross connection of devices 3P+N + 1P+N (phase sequence L1-L2-L3-N-L1-N-L2-N-L1-N-...) N NBusbars for IT networks I TBusbars acc. to UL 489 (Branch Protection) B PBusbars acc. to UL 1077 (Supplementary Protection) S P

Note: Combinations of above applications are possible

6 7 7

*) only right side mounted auxiliary elements and bottom fixed auxiliary contacts can be considered for busbar connection

PS / /

Page 42: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

42 Line Protection Equipment 0115 ABB Low Voltage 43 Line Protection Equipment 0115 ABB Low Voltage

Pre-assembled busbars (not to be cut)1-phase busbars, pin distance 17.6 mm, end caps PS-END 0

No. of pins Phases mm2 Part NumberProduct Hierarchy

2400002 Order Code

2 1 10 PS1/2 2CDL 210 001 R1002

3 1 10 PS1/3 2CDL 210 001 R1003

4 1 10 PS1/4 2CDL 210 001 R1004

6 1 10 PS1/6 2CDL 210 001 R1006

9 1 10 PS1/9 2CDL 210 001 R1009

12 1 10 PS1/12 2CDL 210 001 R1012

12 1 10 PS1/12A 2) 2CDL 210 010 R1012

3-phase busbars, pin distance 17.6 mm

6 3 10 PS3/6 2CDL 231 001 R1006

9 3 10 PS3/9 2CDL 231 001 R1009

12 3 10 PS3/12 2CDL 231 001 R1012

12 3 10 PS3/12FI * 2CDL 231 002 R1012 * phase sequence: L1, L2, L3, free, L2, L3, L1, ...

Busbars suitable for cutting1-phase busbars, pin distance 17.6 mm, end caps PS-END 0

60 1 10 PS1/60 2CDL 210 001 R1060

60 1 10 PS1/60A 2) 2CDL 210 010 R1060

60 1 16 PS1/60/16 2CDL 210 001 R1660

60 1 16 PS1/60/16A 2) 2CDL 210 010 R1660

5 1 30 PS1/5/30 1) 2CDL 210 001 R3005

10 1 30 PS1/10/30 1) 2CDL 210 001 R3010

11 1 30 PS1/11/30 1) 2CDL 210 001 R3011

14 1 30 PS1/14/30 1) 2CDL 210 001 R3014

15 1 30 PS1/15/30 1) 2CDL 210 001 R3015

18 1 30 PS1/18/30 1) 2CDL 210 001 R3018

19 1 30 PS1/19/30 1) 2CDL 210 001 R3019

60 1 30 PS1/60/30 2CDL 210 001 R3060

1-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END 0

38 1 10 PS1/38H 2CDL 210 001 R1038

38 1 16 PS1/38/16H 2CDL 210 001 R1638

1-phase busbars, connection of neutral (blue insulation), end caps END 1.1

28 1 10 PS1/28N 2CDL 210 001 R1028

28 1 16 PS1/28/16N 2CDL 210 001 R1628

57 1 10 PS1/57NA 2) 2CDL 210 011 R1057

57 1 10 PS1/57N 2CDL 210 001 R1057

57 1 16 PS1/57/16NA 2) 2CDL 210 011 R1657

57 1 16 PS1/57/16N 2CDL 210 001 R1657

1-phase busbars, connection of auxiliaries, end caps END 1.1 except PS 1/57/6

23 1 6 PS1/23/6 2CDL 210 005 R0623

29 1 6 PS1/29/6 2CDL 210 005 R0629

38 1 6 PS1/38/6 2CDL 210 005 R0638

57 1 6 PS1/57/6 2CDL 210 005 R0657

1-phase busbars, connection of hand operated neutral S2C-Nt (blue insulation),end caps END 1.1

38 1 10 PS1/38 NT 2CDL 210 002 R1038

Busbars and accessories for MCBs S 200, RCDs F 200 and DS 200 series

PS 1/2 - PS 1/12

PS 3/6 - PS 3/12

1) inclusive of end caps2) pre-cutted pins3) use end cap PS-END 34) use end cap PS-END 3.15) removal of installed MCB not possible

Page 43: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

42 Line Protection Equipment 0115 ABB Low Voltage 43 Line Protection Equipment 0115 ABB Low Voltage

Busbars suitable for cutting

No. of pins Phases mm2 Part NumberProduct Hierarchy

2400002 Order Code

2-phase busbars, pin distance 17.6 mm, end caps PS-END

12 2 10 PS2/12 1) 2CDL 220 001 R1012

12 2 10 PS2/12A 1) 2) 2CDL 220 010 R1012

12 2 16 PS2/12/16 2CDL 220 001 R1612

58 2 10 PS2/58 2CDL 220 001 R1058

58 2 16 PS2/58/16 2CDL 220 001 R1658

58 2 16 PS2/58/16A 2) 2CDL 220 010 R1658

58 2 30 PS2/58/30 3) 4) 2CDL 220 001 R3058

Note: PS...A is a busbar with removable pin

2-phase busbars, connection of 2-pole devices with auxiliary, end caps PS-END

48 2 10 PS2/48H 2CDL 220 001 R1048

48 2 16 PS2/48/16H 2CDL 220 001 R1648

48 2 16 PS2/48/16HA 2) 2CDL 220 012 R1648

3-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END

11 3 10 PS3/11 1) 2CDL 230 001 R1011

12 3 10 PS3/12 1) 2CDL 230 001 R1012

12 3 10 PS3/12A 1) 2) 2CDL 230 010 R1012

12 3 16 PS3/12/16 1) 2CDL 230 001 R1612

60 3 10 PS3/60 2CDL 230 001 R1060

60 3 10 PS3/60A 2) 2CDL 230 010 R1060

60 3 16 PS3/60/16 2CDL 230 001 R1660

60 3 16 PS3/60/16A 2) 2CDL 230 010 R1660

60 3 30 PS3/60/30 3) 5) 2CDL 230 001 R3060

3-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END

39 3 10 PS3/39H 2CDL 230 001 R1039

39 3 16 PS3/39/16H 2CDL 230 001 R1639

3-phase busbars, connection of 2-pole devices (Phase+N) with auxiliary, end caps PS-END

24 3 10 PS3/24H 2CDL 230 001 R1024

3-phase busbars, connection of 2-pole devices (Phase+Phase) with auxiliary, end caps PS-END

46 3 16 PS3/46/16H-IT 2CDL 230 001 R1646

3-phase busbars, connection of 3-pole devices with auxiliary, end caps PS-END

48 3 10 PS3/48H 2CDL 230 001 R1048

48 3 16 PS3/48/16H 2CDL 230 001 R1648

48 3 16 PS3/48/16HA 2) 2CDL 230 012 R1648

3-phase busbars, connection of 1+N or RCBOs, end caps PS-END

30 3 10 PS3/30 2CDL 230 001 R1030

3-phase busbars, N of the RCD omitted, end caps PS-END

9 3 10 PS3/9FI 1) 2CDL 230 002 R1009

10 3 10 PS3/10FI 1) 2CDL 230 002 R1010

12 3 10 PS3/12FI 1) 2CDL 230 002 R1012

57 3 10 PS3/57FI 2CDL 230 002 R1057

Busbars and accessories for MCBs S 200, RCDs F 200 and DS 200 series

1) inclusive of end caps2) pre-cutted pins3) use end cap PS-END 34) use end cap PS-END 3.15) removal of installed MCB not possible

Page 44: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

44 Line Protection Equipment 0115 ABB Low Voltage 45 Line Protection Equipment 0115 ABB Low Voltage

Busbars suitable for cutting3-phase busbars, N of the RCD omitted, with auxilary at RCD end caps PS-END

No. of pins Phases mm2 Part NumberProduct Hierarchy

2400002 Order Code

12 3 10 PS3/12FIH 1) 2CDL 230 003 R1012

4-phase busbars, pin distance 17.6 mm, end caps PS-END 1

12 4 10 PS4/12 1) 2CDL 240 101 R1012

12 4 10 PS4/12A 1) 2) 2CDL 240 110 R1012

12 4 16 PS4/12/16 1) 2CDL 240 101 R1612

60 4 10 PS4/60 2CDL 240 101 R1060

60 4 16 PS4/60/16 2CDL 240 101 R1660

60 4 16 PS4/60/16A 2) 2CDL 240 110 R1660

60 4 30 PS4/60/30 4) 5) 2CDL 240 001 R3060

Note: PS...A is a busbar with removable pin

4-phase busbars, connection of 4-pole devices with auxiliary, end caps PS-END 1

52 4 16 PS4/52/16H 2CDL 240 101 R1652

52 4 16 PS4/52/16HA 2) 2CDL 240 212 R1652

4-phase busbars, connection of 1+N or RCBOs, end caps PS-END 1

12 4 10 PS4/12NA 1) 2) 2CDL 240 213 R1012

58 4 10 PS4/58N 2CDL 240 101 R1058

58 4 16 PS4/58/16N 2CDL 240 101 R1658

58 4 16 PS4/58/16NA 2) 2CDL 240 213 R1658

4-phase busbars, connection of 1+N or RCBOs with auxiliary, end caps PS-END 1

48 4 16 PS4/48/16NHA 2) 2CDL 240 114 R1648

4-phase busbars, connection of 4-pole RCD with 1+N , end caps PS-END 1

58 4 10 PS4/58NNA 2) 2CDL 240 110 R1058

58 4 16 PS4/58/16NNA 2) 2CDL 240 110 R1658

Busbars suitable for cutting for DDA 200 & DS 200 - bottom mounting RCD3-phase busbars, connection of DDA 202 & DS 202, end caps PS-END 3 (phase sequence L1-L2-free-free-L3-L1....without N)

30 3 10 PS 3/30-DDA 202 2CDL 230 202 R1030

30 3 16 PS 3/30/16-DDA 202 2CDL 230 202 R1630

3-phase busbars, connection of DDA 202 & DS 202, with auxiliary. end caps PS-END 3 (phase sequence L1-L2-aux (free)-free-free-L3-L1-aux (free)....without N)

26 3 16 PS 3/26/16H-DDA 202 2CDL 230 202 R1626

4-phase busbars, connection of DDA 204 63A & DS 204 50A & 63A, end caps PS-END 4 (phase sequence L1-L2-L3-L4-aux free-free-free-free L1....)

32 4 10 PS 4/32-DDA 204 2CDL 240 204 R1032

32 4 16 PS 4/32/16-DDA 204 2CDL 240 204 R1632

Busbars suitable for cutting for DDA 200 & DS 200 - top side mounting MCB2-phase busbars, connection of DDA 202 and DS 202, end caps PSB-END 3 (phase sequence L1-L2/N-free-free-.....)

30 2 16 PS 2/30/16N-DDA 202T 2CDL 020 202 R1630

3-phase busbars, connection of DDA 202 and DS 202, end caps PSB-END 3 (phase sequence L1-L2-free-free-L3-L1.....without N)

30 3 16 PS 3/30/16-DDA 202T 2CDL 033 202 R1630

3-phase busbars, connection of DDA 202 and DS 202 with auxiliary, end caps PSB-END 3 (phase sequence L1-L2-aux.(free)-free-free-L3-L1-aux.(free).....without N)

28 3 16 PS 3/28/16H-DDA 202T 2CDL 034 202 R1628

4-phase busbars, connection of DDA 202 and DS 202, end caps PSB-END 4 (phase sequence L1-N-free-free-L2-N...)

30 4 16 PS 4/30/16N-DDA 202T 2CDL 040 202 R1630

Busbars and accessories for MCBs S 200, RCDs F 200 and DS 200 series

1) inclusive of end caps2) pre-cutted pins3) use end cap PS-END 34) use end cap PS-END 3.15) removal of installed MCB not possible

Page 45: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

44 Line Protection Equipment 0115 ABB Low Voltage 45 Line Protection Equipment 0115 ABB Low Voltage

Accessories for S 200, SN 201, F 200, DS 200 and other series

SZ-BSK

BSK

identification label

End Caps Part NumberProduct Hierarchy

2400002 Order Code

END 1.1 2CDL 200 011 R0011

PS-END 0 2CDL 200 011 R0004

PS-END 2CDL 200 011 R1001

PS-END 1 2CDL 200 011 R0002

PS-END SP 2CDL 200 110 R0001

PS-END 1 SP 2CDL 200 110 R0002

PS-END 3 2CDL 200 001 R3001

PS-END 3.1 2CDL 200 001 R3002

PSB-END 3 GHV0 361 325 R0001

PSB-END 3 GHV0 361 325 R0002

Shock-protection caps for PS...5 parts SZ-BSK 2CDL 200 001 R0011

5 parts BSK* 2CDL 200 001 R0012

* closed version

Labelling systemPackage comes with 40 labels, marked or blank. Blank labels can be labeled by hand with an indelible, waterproof pen or using a computerised labelling system (plotter).

identification labels blank BS GH S200 1946 R0001

identification labels with pictograms BS Pikto GH S200 1946 R0002

identification labels marked 4 x 1 – 10 BS 1/10 GH S200 1946 R0003

identification labels marked 2 x 1 – 20 BS 1/20 GH S200 1946 R0004

identification labels marked 1 – 40 BS 1/40 GH S200 1946 R0005

identification labels marked 41 – 80 BS 41 – 80 GH S200 1946 R0006

identification labels marked 81 – 120 BS 81 – 120 GH S200 1946 R0007

identification labels marked 121 – 160 BS 121/160 GH S200 1946 R0008

Identification system ILS

The ILS individual identification sytem for labels is a DIN A5 polyester film for ink jet and laser printers with high temperature resistance. (If laser printers are used, please check whether self-adhesive film with thickness of 250 µm can be fed.) Adhesive coating 3MTM9471 LE has obtained UL approval (file No. MH 11410). There are two types of sheet: uncut for making individual labels or precut with 23 stripes (6 x 191 mm each) for labelling 11 devices (1-module width) per stripe. Word template can be downloaded from www.abb.de/stotz-kontakt. Can also be used as write-on labels (ink, ballpoint pen, pencil, marker).

1 sheet DIN A5 uncut for laser printer ILS-L 2CDL 200 002 R0003

1 sheet DIN A5 precut in 23 stripes (6 x 191 mm) for laser printer ILS-LS 2CDL 200 002 R0004

1 sheet DIN A5 uncut for inkjet printer ILS-I 2CDL 200 002 R0005

1 sheet DIN A5 precut in 23 stripes (6 x 191 mm) for inkjet printer IILS-IS 2CDL 200 002 R0006

BS 1/10

Page 46: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

46 Line Protection Equipment 0115 ABB Low Voltage 47 Line Protection Equipment 0115 ABB Low Voltage

SZ-ESK 2

SZ-ESK 3

SZ-ESK 3 S

Accessories for S 200, SN 201, F 200, DS 200 and other series

Terminals, insulated with pin contact

Terminal capacity mm2Terminal lug L x W mm Type connection Part Number

Product Hierarchy 2400002 Order Code

6-25 15/4 90° Ast 25/15 QS 2CDL200010R2515

6-25 15/4 straight Ast 25/15 S 2CDL200011R2515

6-25 15/6 90° Ast 25/15 Q 2CDL200000R2515

6-25 22/4 90° Ast 25/22 QS 2CDL200010R2522

6-25 30/4 90° Ast 25/30 QS 2CDL200010R2530

6-25 30/6 90° Ast 25/30 Q 2CDL200000R2530

6-50 15/4 90° Ast 50/15 QS 2CDL200000R5015

6-50 15/4 straight Ast 50/15 S 2CDL200011R5015

6-50 15/7 90° Ast 50/15 Q 2CDL200010R5015

6-50 15/7 straight Ast 50/15 2CDL200001R5015

5-50 17.5/7 90° Ast 50/18 Q 2CDL200100R5018

6-50 17.5/7 straight Ast 50/18 2CDL200101R5018

6-50 32/6 90° Ast 50/32 Q 2CDL200000R5032

25-95 21/6.5 straight SZ-Ast 95 gk* GHV0360501R0012

25-95 21/6.5 straight SZ-Ast 95* GHV0360501R0013

Abbreviations: Q terminal 90° * not for pro M compact S narrow connection pin

Feeder terminals

Single-pole terminals can be mounted side by side with multipole terminals.

Input mm2 Part NumberProduct Hierarchy

2400002 Order Code

6-35 SZ-ESK 2 2CDL200001R3501

6-50 SZ-ESK 3 2CDL200003R5001

6-50 SZ-ESK 3 S 2CDL200003R5003

AccessoriesFor device covers with materials of a thickness of 1 to 3 mm, width: 1 module = 17.5 mm; color: grey RAL 7035, white RAL 9001

End bracket

Prevents lateral shifting of built-in devices mounted on DIN rails according to DIN EN 60 715, 35 x 7.5 mm. END GJ I100 1814 R0001

Filling piece

For heat dissipation of closely mounted devices that generate much heat. Width 8.75 mm, as spacer, two different heights, breakable, for DIN rails according to DIN EN 60 715, 35 x 7.5 mm.

SZ-FST 2 GH L530 1908 R0002

Spring piece

Holder for device covers, various heights available (in connection with FST 2 filling piece) SZ-FDT 2 GH L530 1908 R0005

SZ-VP 1500

SZ-FDT 2

END

Filling pieceTwo different heights, breakable, for DIN rails according to DIN EN 60 715, 35 x 7.5 mm for MCBs S 220 (3 different heights)

Description Part NumberProduct Hierarchy

2400002 Order Code

Width 8.75mm SZ-FST GJ I148 0003 R0001

False poles

False pole - 1 module FP1 16021765

False pole - 2 modules FP2 16021773

False pole - 4 modules FP4 16021781

False pole - 6 modules FP6 16021799

Support for false pole SFP 16021831

FP

SZ-FST

Ast 25/15 QSAst 25/15 QAst 25/30 QSAst 25/30 QAst 50/15 QSAst 50/15 QAst 50/18 Q

Ast 50/32 Q

SZ-Ast 95 gk

Ast 25/15 SAst 50/15 SAst 50/15Ast 50/18

SZ-Ast 95

Ast 50/32 Q

Page 47: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

46 Line Protection Equipment 0115 ABB Low Voltage 47 Line Protection Equipment 0115 ABB Low Voltage

AccessoriesProduct Hierarchy 2400002

Order CodeDescription Part No

Signal contactsAux contact S800-AUX 2CCS800900R0011

Aux/signal contact S800-AUX/ALT 2CCS800900R0021

Switched neutralSwitched neutral 63A S800-NT 2CCS800900R0061

Shunt trips24v AC/DC S800-SOR24 2CCS800900R0191

48...130v AC/DC S800-SOR130 2CCS800900R0221

110...250v AC/DC S800-SOR250 2CCS800900R0211

220...400v AC/DC S800-SOR400 2CCS800900R0231

Under voltage release24...36v AC/DC S800-UVR36 2CCS800900R0241

48...60v AC/DC S800-UVR60 2CCS800900R0251

110...130v AC/DC S800-UVR130 2CCS800900R0261

220...250v AC/DC S800-UVR250 2CCS800900R0271

HandlesRotary drive S800-RD 2CCS800900R0041

Black rotary handle S800-RHE-H 1SDA060150R1

Red/emergency rotary handle S800-RHE-EM 1SDA060151R1

Axial extension 500mm for RHE S800-RHE-S 1SDA060179R1

General accessoriesIntermediate piece 9mm S800-IP9 2CCS800900R0031

Padlock device with 4mm hasp S800-PLL 2CCS800900R0051

UL locking device S800U-PLL 2CCS800017R0001

Busbar 250A S803-BB250 2CCS800900R0071

Busbar powr connection 120mm2 S803-BBPC120 2CCS800900R0101

Busbar isolation cao S800-BBIC 2CCS800900R0081

End cap S800-END 2CCS800900R0091

System ProM compactAccessories S800

ì

ìñêî ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ß«¨·´·¿®§ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ ½±²¬¿½¬ îðêèðî ÍèððóßËÈ îÝÝÍèððçððÎððïï ðòðìç ï

ݱ³¾·²»¼ ¿«¨·´·¿®§ ¿²¼ ­·¹²¿´ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ñ­·¹²¿´ ½±²¬¿½¬ îðêèïç ÍèððóßËÈñßÔÌ îÝÝÍèððçððÎððîï ðòðëð ï

Í»°¿®¿¬·²¹ ²»«¬®¿´

Ü»­½®·°¬·±² Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

Í»°¿®¿¬·²¹ ²»«¬®¿´ êíß îðèïçê ÍèððóÒÌ îÝÝÍèððçððÎððêï ðòïïë ï

͸«²¬ ±°»®¿¬·±² ®»´»¿­»­

Ü»­½®·°¬·±²

Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îÊßÝñÜÝ îïîðéð ÍèððóÍÑÎïî îÝÝÍèððçððÎðïçï ðòïë ï

îìÊßÝñÜÝ îðèíïè ÍèððóÍÑÎîì îÝÝÍèððçððÎðïçï ðòïë ï

ìèòòòïíðÊßÝñÜÝ îðèíìç ÍèððóÍÑÎïíð îÝÝÍèððçððÎðîîï ðòïë ï

ïïðòòòîëðÊßÝñÜÝ îðèííî ÍèððóÍÑÎîëð îÝÝÍèððçððÎðîïï ðòïë ï

îîðòòòìððÊßÝñÜÝ îðèíëê ÍèððóÍÑÎìðð îÝÝÍèððçððÎðîíï ðòïë ï

˲¼»® ª±´¬¿¹» ®»´»¿­»­

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îìòòòíêÊßÝñÜÝ îðèíêí ÍèððóËÊÎíê îÝÝÍèððçððÎðîìï ðòïë ï

ìèòòòêðÊßÝñÜÝ îðèíéð ÍèððóËÊÎêð îÝÝÍèððçððÎðîëï ðòïë ï

ïïðòòòïíðÊßÝñÜÝ îðèíèé ÍèððóËÊÎïíð îÝÝÍèððçððÎðîêï ðòïë ï

îîðòòòîëðÊßÝñÜÝ îðèíçì ÍèððóËÊÎîëð îÝÝÍèððçððÎðîéï ðòïë ï

îÝ

ÝÝ

ìï

íî

íç

Úî

ÝÝ

Ýì

ïí

îì

ðÚ

ß½½»­­±®·»­ º±®Íèðð

îÝ

ÝÝ

ìï

íð

êç

Úð

ðð

ïî

ÝÝ

Ýì

ïí

ðé

ðÚ

ðð

ðï

îÝ

ÝÝ

ìï

íð

êé

Úð

ðð

ï

ÍèððóßËÈ

ÍèððóßËÈóßÔÌ

ÍèððóÒÌ

ÍèððóÍÑÎ

ÍèððóËÊÎ

ì

ìñêî ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ß«¨·´·¿®§ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ ½±²¬¿½¬ îðêèðî ÍèððóßËÈ îÝÝÍèððçððÎððïï ðòðìç ï

ݱ³¾·²»¼ ¿«¨·´·¿®§ ¿²¼ ­·¹²¿´ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ñ­·¹²¿´ ½±²¬¿½¬ îðêèïç ÍèððóßËÈñßÔÌ îÝÝÍèððçððÎððîï ðòðëð ï

Í»°¿®¿¬·²¹ ²»«¬®¿´

Ü»­½®·°¬·±² Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

Í»°¿®¿¬·²¹ ²»«¬®¿´ êíß îðèïçê ÍèððóÒÌ îÝÝÍèððçððÎððêï ðòïïë ï

͸«²¬ ±°»®¿¬·±² ®»´»¿­»­

Ü»­½®·°¬·±²

Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îÊßÝñÜÝ îïîðéð ÍèððóÍÑÎïî îÝÝÍèððçððÎðïçï ðòïë ï

îìÊßÝñÜÝ îðèíïè ÍèððóÍÑÎîì îÝÝÍèððçððÎðïçï ðòïë ï

ìèòòòïíðÊßÝñÜÝ îðèíìç ÍèððóÍÑÎïíð îÝÝÍèððçððÎðîîï ðòïë ï

ïïðòòòîëðÊßÝñÜÝ îðèííî ÍèððóÍÑÎîëð îÝÝÍèððçððÎðîïï ðòïë ï

îîðòòòìððÊßÝñÜÝ îðèíëê ÍèððóÍÑÎìðð îÝÝÍèððçððÎðîíï ðòïë ï

˲¼»® ª±´¬¿¹» ®»´»¿­»­

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îìòòòíêÊßÝñÜÝ îðèíêí ÍèððóËÊÎíê îÝÝÍèððçððÎðîìï ðòïë ï

ìèòòòêðÊßÝñÜÝ îðèíéð ÍèððóËÊÎêð îÝÝÍèððçððÎðîëï ðòïë ï

ïïðòòòïíðÊßÝñÜÝ îðèíèé ÍèððóËÊÎïíð îÝÝÍèððçððÎðîêï ðòïë ï

îîðòòòîëðÊßÝñÜÝ îðèíçì ÍèððóËÊÎîëð îÝÝÍèððçððÎðîéï ðòïë ï

îÝ

ÝÝ

ìï

íî

íç

Úî

ÝÝ

Ýì

ïí

îì

ðÚ

ß½½»­­±®·»­ º±®Íèðð

îÝ

ÝÝ

ìï

íð

êç

Úð

ðð

ïî

ÝÝ

Ýì

ïí

ðé

ðÚ

ðð

ðï

îÝ

ÝÝ

ìï

íð

êé

Úð

ðð

ï

ÍèððóßËÈ

ÍèððóßËÈóßÔÌ

ÍèððóÒÌ

ÍèððóÍÑÎ

ÍèððóËÊÎ

ì

ìñêî ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ß«¨·´·¿®§ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ ½±²¬¿½¬ îðêèðî ÍèððóßËÈ îÝÝÍèððçððÎððïï ðòðìç ï

ݱ³¾·²»¼ ¿«¨·´·¿®§ ¿²¼ ­·¹²¿´ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ñ­·¹²¿´ ½±²¬¿½¬ îðêèïç ÍèððóßËÈñßÔÌ îÝÝÍèððçððÎððîï ðòðëð ï

Í»°¿®¿¬·²¹ ²»«¬®¿´

Ü»­½®·°¬·±² Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

Í»°¿®¿¬·²¹ ²»«¬®¿´ êíß îðèïçê ÍèððóÒÌ îÝÝÍèððçððÎððêï ðòïïë ï

͸«²¬ ±°»®¿¬·±² ®»´»¿­»­

Ü»­½®·°¬·±²

Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îÊßÝñÜÝ îïîðéð ÍèððóÍÑÎïî îÝÝÍèððçððÎðïçï ðòïë ï

îìÊßÝñÜÝ îðèíïè ÍèððóÍÑÎîì îÝÝÍèððçððÎðïçï ðòïë ï

ìèòòòïíðÊßÝñÜÝ îðèíìç ÍèððóÍÑÎïíð îÝÝÍèððçððÎðîîï ðòïë ï

ïïðòòòîëðÊßÝñÜÝ îðèííî ÍèððóÍÑÎîëð îÝÝÍèððçððÎðîïï ðòïë ï

îîðòòòìððÊßÝñÜÝ îðèíëê ÍèððóÍÑÎìðð îÝÝÍèððçððÎðîíï ðòïë ï

˲¼»® ª±´¬¿¹» ®»´»¿­»­

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îìòòòíêÊßÝñÜÝ îðèíêí ÍèððóËÊÎíê îÝÝÍèððçððÎðîìï ðòïë ï

ìèòòòêðÊßÝñÜÝ îðèíéð ÍèððóËÊÎêð îÝÝÍèððçððÎðîëï ðòïë ï

ïïðòòòïíðÊßÝñÜÝ îðèíèé ÍèððóËÊÎïíð îÝÝÍèððçððÎðîêï ðòïë ï

îîðòòòîëðÊßÝñÜÝ îðèíçì ÍèððóËÊÎîëð îÝÝÍèððçððÎðîéï ðòïë ï

îÝ

ÝÝ

ìï

íî

íç

Úî

ÝÝ

Ýì

ïí

îì

ðÚ

ß½½»­­±®·»­ º±®Íèðð

îÝ

ÝÝ

ìï

íð

êç

Úð

ðð

ïî

ÝÝ

Ýì

ïí

ðé

ðÚ

ðð

ðï

îÝ

ÝÝ

ìï

íð

êé

Úð

ðð

ï

ÍèððóßËÈ

ÍèððóßËÈóßÔÌ

ÍèððóÒÌ

ÍèððóÍÑÎ

ÍèððóËÊÎ

ì

ìñêî ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ß«¨·´·¿®§ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ ½±²¬¿½¬ îðêèðî ÍèððóßËÈ îÝÝÍèððçððÎððïï ðòðìç ï

ݱ³¾·²»¼ ¿«¨·´·¿®§ ¿²¼ ­·¹²¿´ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ñ­·¹²¿´ ½±²¬¿½¬ îðêèïç ÍèððóßËÈñßÔÌ îÝÝÍèððçððÎððîï ðòðëð ï

Í»°¿®¿¬·²¹ ²»«¬®¿´

Ü»­½®·°¬·±² Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

Í»°¿®¿¬·²¹ ²»«¬®¿´ êíß îðèïçê ÍèððóÒÌ îÝÝÍèððçððÎððêï ðòïïë ï

͸«²¬ ±°»®¿¬·±² ®»´»¿­»­

Ü»­½®·°¬·±²

Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îÊßÝñÜÝ îïîðéð ÍèððóÍÑÎïî îÝÝÍèððçððÎðïçï ðòïë ï

îìÊßÝñÜÝ îðèíïè ÍèððóÍÑÎîì îÝÝÍèððçððÎðïçï ðòïë ï

ìèòòòïíðÊßÝñÜÝ îðèíìç ÍèððóÍÑÎïíð îÝÝÍèððçððÎðîîï ðòïë ï

ïïðòòòîëðÊßÝñÜÝ îðèííî ÍèððóÍÑÎîëð îÝÝÍèððçððÎðîïï ðòïë ï

îîðòòòìððÊßÝñÜÝ îðèíëê ÍèððóÍÑÎìðð îÝÝÍèððçððÎðîíï ðòïë ï

˲¼»® ª±´¬¿¹» ®»´»¿­»­

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îìòòòíêÊßÝñÜÝ îðèíêí ÍèððóËÊÎíê îÝÝÍèððçððÎðîìï ðòïë ï

ìèòòòêðÊßÝñÜÝ îðèíéð ÍèððóËÊÎêð îÝÝÍèððçððÎðîëï ðòïë ï

ïïðòòòïíðÊßÝñÜÝ îðèíèé ÍèððóËÊÎïíð îÝÝÍèððçððÎðîêï ðòïë ï

îîðòòòîëðÊßÝñÜÝ îðèíçì ÍèððóËÊÎîëð îÝÝÍèððçððÎðîéï ðòïë ï

îÝ

ÝÝ

ìï

íî

íç

Úî

ÝÝ

Ýì

ïí

îì

ðÚ

ß½½»­­±®·»­ º±®Íèðð

îÝ

ÝÝ

ìï

íð

êç

Úð

ðð

ïî

ÝÝ

Ýì

ïí

ðé

ðÚ

ðð

ðï

îÝ

ÝÝ

ìï

íð

êé

Úð

ðð

ï

ÍèððóßËÈ

ÍèððóßËÈóßÔÌ

ÍèððóÒÌ

ÍèððóÍÑÎ

ÍèððóËÊÎ

ì

ìñêî ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï

ß«¨·´·¿®§ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ ½±²¬¿½¬ îðêèðî ÍèððóßËÈ îÝÝÍèððçððÎððïï ðòðìç ï

ݱ³¾·²»¼ ¿«¨·´·¿®§ ¿²¼ ­·¹²¿´ ½±²¬¿½¬

Ü»­½®·°¬·±² Þ¾²éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß«¨·´·¿®§ñ­·¹²¿´ ½±²¬¿½¬ îðêèïç ÍèððóßËÈñßÔÌ îÝÝÍèððçððÎððîï ðòðëð ï

Í»°¿®¿¬·²¹ ²»«¬®¿´

Ü»­½®·°¬·±² Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

Í»°¿®¿¬·²¹ ²»«¬®¿´ êíß îðèïçê ÍèððóÒÌ îÝÝÍèððçððÎððêï ðòïïë ï

͸«²¬ ±°»®¿¬·±² ®»´»¿­»­

Ü»­½®·°¬·±²

Þ¾²

éêïîîéï ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îÊßÝñÜÝ îïîðéð ÍèððóÍÑÎïî îÝÝÍèððçððÎðïçï ðòïë ï

îìÊßÝñÜÝ îðèíïè ÍèððóÍÑÎîì îÝÝÍèððçððÎðïçï ðòïë ï

ìèòòòïíðÊßÝñÜÝ îðèíìç ÍèððóÍÑÎïíð îÝÝÍèððçððÎðîîï ðòïë ï

ïïðòòòîëðÊßÝñÜÝ îðèííî ÍèððóÍÑÎîëð îÝÝÍèððçððÎðîïï ðòïë ï

îîðòòòìððÊßÝñÜÝ îðèíëê ÍèððóÍÑÎìðð îÝÝÍèððçððÎðîíï ðòïë ï

˲¼»® ª±´¬¿¹» ®»´»¿­»­

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½»

µ¹

п½µ«²·¬

°½ò̧°» ½±¼» Ñ®¼»® ½±¼»

îìòòòíêÊßÝñÜÝ îðèíêí ÍèððóËÊÎíê îÝÝÍèððçððÎðîìï ðòïë ï

ìèòòòêðÊßÝñÜÝ îðèíéð ÍèððóËÊÎêð îÝÝÍèððçððÎðîëï ðòïë ï

ïïðòòòïíðÊßÝñÜÝ îðèíèé ÍèððóËÊÎïíð îÝÝÍèððçððÎðîêï ðòïë ï

îîðòòòîëðÊßÝñÜÝ îðèíçì ÍèððóËÊÎîëð îÝÝÍèððçððÎðîéï ðòïë ï

îÝ

ÝÝ

ìï

íî

íç

Úî

ÝÝ

Ýì

ïí

îì

ðÚ

ß½½»­­±®·»­ º±®Íèðð

îÝ

ÝÝ

ìï

íð

êç

Úð

ðð

ïî

ÝÝ

Ýì

ïí

ðé

ðÚ

ðð

ðï

îÝ

ÝÝ

ìï

íð

êé

Úð

ðð

ï

ÍèððóßËÈ

ÍèððóßËÈóßÔÌ

ÍèððóÒÌ

ÍèððóÍÑÎ

ÍèððóËÊÎ

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñêí

îÝ

ÝÝ

ìï

íð

êï

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êî

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êì

Úð

ðð

ï

ન®§ ¼®·ª» ¿¼¿°¬»® º±® íóìó°±´» Ø·¹¸ л®º±®³¿²½» ÓÝÞ

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ન®§ Ü®·ª» îðèïéî ÍèððóÎÜ îÝÝÍèððçððÎððìï ðòðèð ï

ß²¬¸®¿½·¬»ñͬ¿²¼¿®¼ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß²¬¸®¿½·¬» ®±¬¿®§ ¸¿²¼´» êîëééï ÍèððóÎØÛóØ ïÍÜßðêðïëðÎï ðòîï ï

λ¼ñÛ³»®¹»²½§ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

λ¼ ®±¬¿®§ ¸¿²¼´» êîëéêì ÍèððóÎØÛóÛÓ ïÍÜßðêðïëïÎï ðòîï ï

ߨ·¿´ »¨¬»²­·±² ±º ®±¬¿®§ ¼®·ª» ®±¬¿®§ ¸¿²¼´» ëðð³³

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ߨ·¿´ »¨¬»²­·±² ëðð³³ º±® ÎØÛ êîêîìî ÍèððóÎØÛóÍ ïÍÜßðêðïéçÎï ðòïç ï

×Ðëì °®±¬»½¬·±² º±® ®±¬¿®§ ¸¿²¼´»

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

×Ðëì µ·¬ êîêîëç ÍèððóÎØÛó×Ðëì ïÍÜßðêðïèðÎï ðòðéë ï

ÍèððóÎÜ

ÍèððóÎØÛóØ

ÍèððóÎØÛóÓ

ÍèððóÎØÛóÍ

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñêí

îÝ

ÝÝ

ìï

íð

êï

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êî

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êì

Úð

ðð

ï

ન®§ ¼®·ª» ¿¼¿°¬»® º±® íóìó°±´» Ø·¹¸ л®º±®³¿²½» ÓÝÞ

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ન®§ Ü®·ª» îðèïéî ÍèððóÎÜ îÝÝÍèððçððÎððìï ðòðèð ï

ß²¬¸®¿½·¬»ñͬ¿²¼¿®¼ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß²¬¸®¿½·¬» ®±¬¿®§ ¸¿²¼´» êîëééï ÍèððóÎØÛóØ ïÍÜßðêðïëðÎï ðòîï ï

λ¼ñÛ³»®¹»²½§ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

λ¼ ®±¬¿®§ ¸¿²¼´» êîëéêì ÍèððóÎØÛóÛÓ ïÍÜßðêðïëïÎï ðòîï ï

ߨ·¿´ »¨¬»²­·±² ±º ®±¬¿®§ ¼®·ª» ®±¬¿®§ ¸¿²¼´» ëðð³³

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ߨ·¿´ »¨¬»²­·±² ëðð³³ º±® ÎØÛ êîêîìî ÍèððóÎØÛóÍ ïÍÜßðêðïéçÎï ðòïç ï

×Ðëì °®±¬»½¬·±² º±® ®±¬¿®§ ¸¿²¼´»

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

×Ðëì µ·¬ êîêîëç ÍèððóÎØÛó×Ðëì ïÍÜßðêðïèðÎï ðòðéë ï

ÍèððóÎÜ

ÍèððóÎØÛóØ

ÍèððóÎØÛóÓ

ÍèððóÎØÛóÍ

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñêí

îÝ

ÝÝ

ìï

íð

êï

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êî

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êì

Úð

ðð

ï

ન®§ ¼®·ª» ¿¼¿°¬»® º±® íóìó°±´» Ø·¹¸ л®º±®³¿²½» ÓÝÞ

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ન®§ Ü®·ª» îðèïéî ÍèððóÎÜ îÝÝÍèððçððÎððìï ðòðèð ï

ß²¬¸®¿½·¬»ñͬ¿²¼¿®¼ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß²¬¸®¿½·¬» ®±¬¿®§ ¸¿²¼´» êîëééï ÍèððóÎØÛóØ ïÍÜßðêðïëðÎï ðòîï ï

λ¼ñÛ³»®¹»²½§ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

λ¼ ®±¬¿®§ ¸¿²¼´» êîëéêì ÍèððóÎØÛóÛÓ ïÍÜßðêðïëïÎï ðòîï ï

ߨ·¿´ »¨¬»²­·±² ±º ®±¬¿®§ ¼®·ª» ®±¬¿®§ ¸¿²¼´» ëðð³³

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ߨ·¿´ »¨¬»²­·±² ëðð³³ º±® ÎØÛ êîêîìî ÍèððóÎØÛóÍ ïÍÜßðêðïéçÎï ðòïç ï

×Ðëì °®±¬»½¬·±² º±® ®±¬¿®§ ¸¿²¼´»

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

×Ðëì µ·¬ êîêîëç ÍèððóÎØÛó×Ðëì ïÍÜßðêðïèðÎï ðòðéë ï

ÍèððóÎÜ

ÍèððóÎØÛóØ

ÍèððóÎØÛóÓ

ÍèððóÎØÛóÍ

ì

ͧ­¬»³ °®± ½±³°¿½¬r ¤ îÝÍÝ ìðð ððî Üðîïï ìñêí

îÝ

ÝÝ

ìï

íð

êï

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êî

Úð

ðð

ï

îÝ

ÝÝ

ìï

íð

êì

Úð

ðð

ï

ન®§ ¼®·ª» ¿¼¿°¬»® º±® íóìó°±´» Ø·¹¸ л®º±®³¿²½» ÓÝÞ

Ü»­½®·°¬·±² Þ¾²éêïîîéï

ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»ï °·»½»

É»·¹¸¬ï °·»½» µ¹

п½µ«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ન®§ Ü®·ª» îðèïéî ÍèððóÎÜ îÝÝÍèððçððÎððìï ðòðèð ï

ß²¬¸®¿½·¬»ñͬ¿²¼¿®¼ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ß²¬¸®¿½·¬» ®±¬¿®§ ¸¿²¼´» êîëééï ÍèððóÎØÛóØ ïÍÜßðêðïëðÎï ðòîï ï

λ¼ñÛ³»®¹»²½§ ®±¬¿®§ ¸¿²¼´» º±® ¼±±® ¿­­»³¾´§

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

λ¼ ®±¬¿®§ ¸¿²¼´» êîëéêì ÍèððóÎØÛóÛÓ ïÍÜßðêðïëïÎï ðòîï ï

ߨ·¿´ »¨¬»²­·±² ±º ®±¬¿®§ ¼®·ª» ®±¬¿®§ ¸¿²¼´» ëðð³³

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

ߨ·¿´ »¨¬»²­·±² ëðð³³ º±® ÎØÛ êîêîìî ÍèððóÎØÛóÍ ïÍÜßðêðïéçÎï ðòïç ï

×Ðëì °®±¬»½¬·±² º±® ®±¬¿®§ ¸¿²¼´»

Ü»­½®·°¬·±² Þ¾²

èðïëêìì ÛßÒ

Ñ®¼»® ¼»¬¿·´­ Ю·½»

ï °·»½»

É»·¹¸¬

ï °·»½» µ¹

п½µ

«²·¬ °½ò̧°» ½±¼» Ñ®¼»® ½±¼»

×Ðëì µ·¬ êîêîëç ÍèððóÎØÛó×Ðëì ïÍÜßðêðïèðÎï ðòðéë ï

ÍèððóÎÜ

ÍèððóÎØÛóØ

ÍèððóÎØÛóÓ

ÍèððóÎØÛóÍ

Page 48: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

48 Line Protection Equipment 0115 ABB Low Voltage 49 Line Protection Equipment 0115 ABB Low Voltage

Part NumberProduct Hierarchy 2700001

Order CodeTimersAnalogue AT1 7 day timer AT1 2CSM204205R0601

Analogue AT1-R 7 day timer with battery reserve AT1-R 2CSM204215R0601

ContactorsESB 20-20 230V Contactor 20A AC1 2NO ESB20-20 GHE3211102R0006

ESB 24-20 230V Contactor 24A AC1 2NO ESB24-20 GHE3291402R0006

ESB 40-40 230V Contactor 40A AC1 4NO ESB40-40 GHE3491102R0006

ESB 63-40 230V Contactor 63A AC1 4NO ESB63-40 GHE3691102R0006

Fuse HoldersE91/32 Fuse disconnector SP 32A 10.3 x 38mm E91/32 2CSM200923R1801

E933/125 Fuse disconnector TP 125A 22 x 58mm E933/125 2CSM373710R1801

Twilight SwitchT1 twighlight switch brightness range 2:200 lux T1 2CSM295563R1341

Modular SocketsDIN rail mounting BS socket M1363 2CSM259343R0721

DIN rail mounting BS socket + light M1363-L 2CSM258163R0721

3/67

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

AT electro-mechanical time switches

They control circuit opening and closing according to scheduled planning. The time switches can be set on

permanent ON-OFF, available both daily and weekly programs. ATS-1R and ATS-7R versions are equipped

with a built-in battery that is generally charged by the network voltage that allows the devices to maintain

the set time programs in case of long (up to 150h) power supply black-out.

ecirPedoC redrOW ssol rewoPstcatnoC

1 CO synchronous 5 VA 02.153TA

1 CO quartz 5 VA AOPR1-STA

1 CO quartz 5 VA AOPR7-STA

2CS

C40

0199

F020

1

2CS

C40

0144

F020

12C

SC

4001

45F0

201

2CS

C40

0198

F020

1DT digital time switches

The range includes single/multichannel daily/weekly/yearly program switches. These are functionally more

sophisticated and control several loads or independent groups of loads requiring different time controls

with a unique time reference. The EEPROM memory of DT series devices eliminates the risk of erasing

confi gured program, regardless the duration of any voltage failure. Yearly models in 6 DIN modules are

endowed with extractable keyboard for an easier setting at the desk.

Contacts complement Description Power loss W Order Code Price

AV 5ylkeeW02 1 DTS 7/1 93.20

AV 5ylkeeW03 2 DTS 7/2 119.86

System ProM CompactAT & DT series time switches

ABB SF Section 3.5.indd 3/67 15/2/07 11:37:32 am

3/63

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

RD2 residual current monitorsResidual current monitors (RCMs) with external transformer can detect leakage currents. Through minidip

you can set sensitivity and intervention time. According to the same diameter, transformers are made in a

single version for all relay sensitivity values.

ecirPedoC redrOV egatlov gnitarepO

230...400 AC 28.8412DR

48...150 AC/DC RD2-48 148.82

Toroidal transformersecirPedoC redrOØ snoisnemiD

29 (modular version) 63.65MRT

35* 80.841RT

60* 08.672RT

80* 94.193RT

160* AOP061RT

210* 84.1125RT

2CS

C40

0320

F020

12C

SC

4004

94F0

201

System ProM CompactRD2 residual current monitors

Technical featuresOperating voltage [V] 230÷400 a.c. (RD2) and

)84-2DR( .c.d/.c.a 051÷84

Frequency [Hz] 50÷60

Sensitivity settings I∆n [A] 0.03; 0.1; 0.3; 0.5; 1; 2

Intervention time [s] Fast (instantaneous); 0.3; 0.5; 1; 2; 5settingsContact capacity [A] 10 at 250 V a.c. (ohmic)

Contact type NC-C-NO

Operatingtemperature [°C] -5…+40

Modules [n°] 2

Standards IEC/EN 62020

IndicationsGreen LED: supply voltage presentRed LED: alarm status

More functionsThe connection between the toroidal transformer and the residual current relay is continually chec-ked by the relay; if the connection interrupts, the residual current relay enters the “alarm” status.The ”test” pushbutton simulates - internally to the RD2 - the residual current conditions for the RD2 to operate. If pushed, the RD2 must enter the alarm status.The “reset” pushbutton allows the residual current relay to return to the starting condition.

If the confi guration is not appropriate, the de-vice will automatically consider as valid the fi rst confi guration (according to the diagram) and enter the maximum safety.O

EP

M02

95

0.03 0.1 0.3 0.5 1 2

Fast 0.3 0.5 1 2 5

0.03I∆n(A)

0.10.30.512

Fast

Time(sec.)

0.30.5125

Selection of calibration

ABB SF Section 3.5.indd 3/63 15/2/07 11:37:25 am

3/66

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

For loads to be automatically controlled through high number of operations; i.e, building automation, controlling of small pumps, ventilations, heating systems, lighting systems, and so on.

ESB series contactorsThe series consists of various models differing in the number of contacts, rated current and control circuit voltage.

ESB20 contactors (20A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

1NO+1NC 12 ESB20-11/12 19.03

1NO+1NC 24 ESB20-11/24 19.03

1NO+1NC 48 ESB20-11/48 19.03

1NO+1NC 110 ESB20-11/110 19.03

1NO+1NC 230 ESB20-11/230 19.03

21CN2 ESB20-02/12 19.03

42CN2 ESB20-02/24 19.03

84CN2 ESB20-02/48 19.93

011CN2 ESB20-02/110 19.93

032CN2 ESB20-02/230 19.93

21ON2 ESB20-20/12 19.93

42ON2 ESB20-20/24 19.03

84ON2 ESB20-20/48 19.03

011ON2 ESB20-20/110 19.03

032ON2 ESB20-20/230 19.03

ESB24 contactors (24A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

21ON4 ESB24-40/12 23.51

42ON4 ESB24-40/24 23.51

032ON4 ESB24-40/230 23.50

2CS

C40

0479

F020

1

2CS

C40

0480

F020

1

ESB40 contactors (40A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

42ON4 ESB40-40/24 41.54

032ON4 ESB40-40/230 41.54

ESB63 contactors (63A)

No. of contacts Command circuits rated voltage Uc VAC Order Code Price

42ON4 ESB63-40/24 63.70

032ON4 ESB63-40/230 63.70

Auxiliary elements & accessories available for ESB24/40/63, EN24/40

ecirPedoC redrOnoitpircseD

Auxiliary elements2NO EH 04/20 12.44

1NO+1NC EH 04/11 12.44

Other accessoriesSpacer ESB-DIS 0.85

Terminal covers for ESB24 ESB-PLK 24 0.55

Terminal covers for ESB40/63 ESB-PLK 40/63 0.73

2CS

C40

0481

F020

12C

SC

4004

82F0

201

System ProM CompactESB series contactors

ABB SF Section 3.5.indd 3/66 15/2/07 11:37:31 am

3/68

www.abb.com/lowvoltage email [email protected] Telephone 02476 368500 Facsimile 02476 368401

3

TW twilight switches with sensor LS-SPThey allow to switch on and/or switch off lighting devices according to the preset ambient light level. They are used in combination with a sensor detecting if ambient light level is higher or lower than the preset threshold. The versions with built-in time switch allow the control of the lighting system in relation to the ambient light level combined with a specifi c time program. All the TWS twilight switches are supplied together with wall mounting sensor.

Channels Order Code Price

1 TWS-1M 97.80

System ProM CompactTW twilight switches

Accessories for TWLS-1 sensor is the same wall mounting sensor which is included in each TWS twilight switch package and it is available as spare part.

Order Code Price

Spare wall mounting sensor AOP1-SL

2CS

C40

0544

F020

1

ABB SF Section 3.5.indd 3/68 15/2/07 11:37:34 am

System ProM compactModular devices

RD2

Operating voltage V Part NoProduct Hierarchy 2700001

Order Code230…400 AC RD2 2CSM142120R1201

48…150 AC/DC RD2-48 2CSM242120R1201

RD312-48 AC/DC RD3-48 2CSJ201001R0001

230-400 AC RD3 2CSJ201001R0002

12-48 AC/DC RD3M-48 2CSJ202001R0001

230-400 AC RD3M 2CSJ202001R0002

12-48 AC/DC RD3P-48 2CSJ203001R0001

230-400 AC RD3P 2CSJ203001R0002

Toroidal TransformersTRM 29mm aperture modular toroid TRM 2CSM029000R1211

TR1 35mm aperture toroid TR1 2CSG035100R1211

TR2 60mm aperture toroid TR2 2CSG060100R1211

TR3 80mm aperture toroid TR3 2CSG080100R1211

TR4 110mm aperture toroid TR4 2CSG110100R1211

TR5 TR5 2CSG210100R1211

TR5A TR5A 2CSG210200R1211

Requires torodial transformer

System ProM compactResidual current relays

3

3/94 2CSC 400 002 D0211 | System pro M compact®

Residual current relaysRD2

Technical features

Operating voltage [V] 230÷400 a.c. (RD2) and

48÷150 a.c./d.c. (RD2-48)

Frequency [Hz] 50÷60

Type A

Operating temperature [°C] -5…+40

Power consumption [W] <3.4, 230 V a.c.

Sensitivity settings I∆n [A] 0.03; 0.1; 0.3; 0.5; 1; 2

Tripping time settings [s] Fast (instantaneous); 0.3; 0.5; 1; 2; 5

Contact capacity [A] 10 at 250 V a.c. (ohmic)

Contact type NC-C-NO

Modules [No.] 2

Protection degree IP20

Standards IEC/EN 62020

RD2 residual current relaysResidual current relays with external toroidal transformer can detect leakage currents. Through minidip it is possible to set sensitivity and intervention time.

Operating voltage

V

Bbn8012542

EAN

Order details Price1 piece

Weight1 piece

kg

Packunit

pc.Type code Order code

230…400 a.c. 058007 RD2 2CSM142120R1201 0.125 1

48…150 a.c./d.c. 537809 RD2-48 2CSM242120R1201 0.125 1

2CS

C40

0320

F020

1

RD2

Where to find more:Wiring Diagrams for RD2 p.11/8 Technical guide of RCDs (code 2CSC420004B0201)

Maybe you are also interested in:Toroidal Transformers p.3/97

3

System pro M compact® | 2CSC 400 002 D0211 3/95

Residual current relaysRD3

Technical features RD3/RD3-48 RD3M/RD3M-48 RD3P/RD3P-48

Operating voltage RD3: 230-400 Vac

+10% / -15%

RD3M: 230-400 Vac

+10% / -15%

RD3P: 230-400 Vac

+10% / -15%

RD3-48: 12-48 Vac/

Vdc +10% / -15%

RD3M-48: 12-48 Vac/

Vdc +10% / -15%

RD3P-48: 12-48 Vac/

Vdc +10% / -15%

Auxiliary supply frequency 50-60 Hz

Frequency filter - Yes Yes

Type A (up to I∆n=5 A)

AC (for higher current)

Operating temperature -25….+70 °C

Power consumption <3.6 W (RD3, RD3M, RD3P),

<600 mW RD3-48, RD3M-48, RD3P-48)

Sensitivity settings I∆n 0.03-0.1-0.3-0.5-1-2-3-5-10-30 A

Tripping time settings ∆t 0-0.06-0.2-0.3-0.5-1-2-3-5-10 s

Pre-alarm threshold - 60% 60%

Max. resistance connection between toroidal transformer and relay

3 Ω

Max. length connection of remote reset button

15 m

Output Contact capacity (7-8-9); (10-11-12)

8 A, 250 V a.c.

Led bar indicator - - Yes

Max. cable terminals section 2.5 mm²

Modules 3

Dimensions 52.8 × 85 × 64.7 mm

Protection degree IP20

Standards IEC/EN 60947-2 annex. M

RD3 residual current relaysThe RD3 family of electronic residual current relays provides residual current protection and monitoring functions according to IEC/EN 60947-2:2006 annex M and can be used in con-junction with all S 200 automatic devices and Tmax range moulded case devices up to T5, for industrial installations.The RD3 residual current relays can provide status indications through two output contacts.

Operating voltage

V

Bbn8012542

EAN

Order details Price1 piece

Weight1 piece

kg

Packunit

pc.Type code Order code

12-48 a.c./d.c. 748236 RD3-48 2CSJ201001R0001 0.13 1

230-400 a.c. 734833 RD3 2CSJ201001R0002 0.25 1

12-48 a.c./d.c. 733935 RD3M-48 2CSJ202001R0001 0.13 1

230-400 a.c. 747031 RD3M 2CSJ202001R0002 0.25 1

12-48 a.c./d.c. 734734 RD3P-48 2CSJ203001R0001 0.13 1

230-400 a.c. 733836 RD3P 2CSJ203001R0002 0.25 1

2CS

C40

0691

F020

12C

SC

4006

90F0

201

2CS

C40

0689

F020

1

RD3

RD3M

RD3P

Where to find more:Wiring Diagrams for RD3 p.11/9 Technical guide of RCDs (code 2CSC420004B0201)

Frequently asked question - FAQ:Tripping time, Cumulative time, Non intervention time for RD3 p.10/159

Maybe you are also interested in:Toroidal Transformers p.3/97

Page 49: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

48 Line Protection Equipment 0115 ABB Low Voltage 49 Line Protection Equipment 0115 ABB Low Voltage

CT Current transformers & energy metersOptimize consumptions, improve efficiency

2 | CT Current transformers

CT Current transformersOptimize consumptions. Improve the efficiency.

To measure is to knowIn an energy market dominated by the need to improve the performance and reduce the consumption of an electrical sys-tem, it becomes vitally important to obtain a detailed profile of how this system operates. This helps in identify areas where consumption can be optimized, efficiency increased and harm-ful emissions reduced.Measuring and monitoring the principal network parameters can substantially contribute in that, by highlighting the level of energy consumption and the quality of the power used, by monitoring and preventing faults and planning maintenance ac-tivities. All this leads to an improved safety level, not only for the installations, but also for the components and systems connected.

ABB Measurement devices range of System pro M compact® includes a comprehensive and specialist offers of DIN rail and front panel devices designed for every type of civil, commercial and industrial applications.

The ideal solution for indirect measurements ABB complete and comprehensive range of CT current trans-formers is the perfect solution for indirect measurement of the electrical parameters that characterize a system, when the net-work current is above the rated current measurement range of the instrument.

Introduction of the CT PRO XT and CT MAX series renews the range of current transformers for secondary and primary sub-distribution switchboards and for Power Centers, by add-ing advanced products that have been specially designed for easy installation and maximum performance. Moreover, high level of safety is guaranteed thanks to the innovative electronic circuit, built-in into the CT… SELV versions.

Energy efficiency, minimized costs and high system availability represent now three central aspects of plant management. To achieve them it is necessary to know when, where and how the energy is consumed. This is why measuring and monitoring the principal electrical parameters of the network is becoming increasingly more and more important.

13334_Trasf_Amp_CT_ENG_DEF.indd 2 15/04/14 17.04

Energy efficiency, minimized costs and high system availability representnow three central aspects of plant management. To achieve them it isnecessary to know when, where and how the energy is consumed. This is why measuring and monitoring the principal electrical parameters of the network is becoming increasingly more and more important.

To measure is to knowIn an energy market dominated by the need to improve the performance and reduce the consumption of an electrical system, it becomes vitally important to obtain a detailed profile of how this system operates. This helps in identify areas where consumption can be optimized, efficiency increased and harmful emissions reduced.

Measuring and monitoring the principal network parameters can substantially contribute in that, by highlighting the level of energy consumption and the quality of the power used, by monitoring and preventing faults and planning maintenance activities. All this leads to an improved safety level, not only for the installations, but also for the components and systems connected.

ABB Measurement devices range of System pro M compact® includes a comprehensive and specialist offers of DIN rail and front panel devices designed for every type of civil, commercial and industrial applications.

The ideal solution for indirect measurementsABB complete and comprehensive range of CT current transformers is the perfect solution for indirect measurement of the electrical parameters that characterize a system, when the network current is above the rated current measurement range of the instrument.

Introduction of the CT PRO XT and CT MAX series renews the range of current transformers for secondary and primary sub distribution switchboards and for Power Centers, by adding advanced products that have been specially designed for easy installation and maximum performance. Moreover, high level of safety is guaranteed thanks to the innovative electronic circuit, built-in into the CT… SELV versions.

Page 50: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

50 Line Protection Equipment 0115 ABB Low Voltage 51 Line Protection Equipment 0115 ABB Low Voltage

B SeriesThe B series EQ meters are meters for single phase and three phase metering. The B series meters are mounted on a DIN rail and are suitable for installation in distribution boards and small enclosures such as consumer units. The B series are suitable in applications where there is a need for reliable energy measurements and where space is limited.

Product Hierarchy 2500003 Order CodeVoltage v Accuracy Class Communication Part No

65 A direct connected, 4 DIN - Steel Active energy, pulse output

3 x 220/380 240/400 V AC Class B (Cl. 1)

- B23 111 - 100 2CMA100163R1000

RS-485 B23 112 - 100 2CMA100164R1000

M-Bus B23 113 - 100 2CMA100165R1000

6 A transformer connected, 4 DIN - Steel Active energy, pulse output

3 x 220/380 240/400 V AC Class B (Cl. 1)

- B24 111 - 100 2CMA100177R1000

RS-485 B24 112 - 100 2CMA100178R1000

M-Bus B24 113 - 100 2CMA100179R1000

6 A transformer connected, 4 DIN - Steel Active energy, pulse output

220/240V AC Class B (Cl. 1)

- B21 111 - 100 2CMA100149R1000

RS-485 B21 112 - 100 2CMA100150R1000

M-Bus B21 113 - 100 2CMA100151R1000

MID Approved electricity metersEQ range B & C Series

C SeriesThe EQ meters, C series are truly compact meters for single phase and three phase metering. The C series is mounted on a DIN rail and is suitable for installation in distribution boards and small consumer units.

Product Hierarchy 2500003 Order CodeVoltage v Accuracy Class Communication Part No

40 A direct connected, 3 DIN - Steel Active energy, pulse output

3 x 240/400 V ACClass B (Cl. 1) - C13 110 - 100 2CMA100191R1000

Class 1 - C13 110 - 300* 2CMA100192R1000

40 A direct connected, 1 DIN, IEC approval Active energy, pulse output

3 x 220/380 240/400 V ACClass B (Cl. 1) - C11 110 - 100 2CMA100014R1000

Class 1 - C11 110 - 300* 2CMA170550R1000

* IEC approval • Active power - Total and per phase• Voltage - Total and per phase• Current - Total and per phase• Power factor• Frequency

EQ meters from ABB for sub-metering provide detailed information about energy consumption. Get specific information on tenants energy consumption or see where in a factory energy is wasted. The EQ meters are high-performing, modular DIN rail-mounted electricity meters that are safe and easy to use. Designed for simple integration with any existing or future electrical installation, the EQ meters from ABB can be installed and functioning in no time. Not only do they provide detailed information about energy consumption, but also act as a tool for building an improved and efficient infrastructure that ultimately leads to a greener world.

MID ApprovedEQ meters from ABB are type approved to IEC and MID. MID-approved meters are certified and have verified meter accuracy, which is a critical factor in the legal cost allocation and distribution among tenants.

Page 51: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

50 Line Protection Equipment 0115 ABB Low Voltage 51 Line Protection Equipment 0115 ABB Low Voltage

CT Current transformers | 3

CT PRO XT, CT MAXPerformance and flexibility.

The new CT PRO XT and CT MAX range of current transformers has been specially designed for easy and safe switchboard installation, testing and maintenance operations thanks to the compact size of the products and their flexible assembly system. Moreover, the integrated electronic protection circuit in the CT PRO XT SELV and CT MAX SELV versions guarantees protection against risks deriving from no-load operation of the secondary.

Double method for connecting the secondary winding, thanks to introduction of screwless terminals, an application standard more and more widespread, that facilitates and speeds up the installation and maintenance operations.

Sealing points for the cover to protect the terminal board of the secondary circuit and to ensure product compliance in applications for fiscal and billing purposes.

The extremely compact dimensions make the product extremely flexible when it comes to installation, and easy to handle during maintenance and tests.

Screw terminals for secondary winding usable with forked cable terminals and stripped cables. The assembly instructions are directly indicated on the product.

Through primary dimensions designed to optimize the product installation (considering rated current values and primary conductor dimensions) and to suit any standard applications requirements.

Marks and approvals attesting the conformity to the principal international standards.

The accessories provided along with the product include a sealable cover for billing applications, and assembly supports allowing the product to be installed in all the more common mounting systems (primary cable, primary busbar, DIN rail and wall-mounting installations).

13334_Trasf_Amp_CT_ENG_DEF.indd 3 15/04/14 17.04

CT Current transformersOptimize consumptions, improve efficiency

The new CT PRO XT and CT MAX range of current transformers has been specially designed for easy and safe switchboard installation, testing and maintenance operations thanks to the compact size of the products and their flexible assembly system. Moreover, the integrated electronic protection circuit in the CT PRO XT SELV and CT MAX SELV versions guarantees protection against risks deriving from no-load operation of the secondary.

A

BCF HGØ

E

L

D

CT Current transformers | 13

CT MAX, CT MAX SELVOrder codes

CT MAXThe CT MAX current transformer range founds its main application in distribution systems with 30x10 mm and 40x10 mm horizontal primary busbars and primary rated current from 300 up to 1000 A. A primary cable up to 30 mm in diameter can also be used. CT MAX transformers are the ideal solution for applications downstream ABB Tmax T5 and T6 circuit-breakers.

CT MAX …/5 A series, through primary

Primary ratedcurrent IprimA

Accurancyclass

Rated power

VA

Bbn8012542EAN

Order details Price1 piece

Weight1 piecekg

Packunitpc.Type code Order code

300 0,5 4 259459 CT MAX 300 2CSG225945R1101 0,32 1

400 0,5 5 259558 CT MAX 400 2CSG225955R1101 0,32 1

500 0,5 6 259558 CT MAX 500 2CSG225965R1101 0,32 1

600 0,5 10 259657 CT MAX 600 2CSG225975R1101 0,32 1

800 0,5 10 259657 CT MAX 800 2CSG225985R1101 0,32 1

1000 0,5 10 259954 CT MAX 1000 2CSG225995R1101 0,32 1

CT MAX SELV …/5 series, through primary

300 0,5 4 260059 CT MAX 300 SELV 2CSG226005R1101 0,37 1

400 0,5 5 260158 CT MAX 400 SELV 2CSG226015R1101 0,37 1

500 0,5 6 260257 CT MAX 500 SELV 2CSG226025R1101 0,37 1

600 0,5 10 260356 CT MAX 600 SELV 2CSG226035R1101 0,37 1

800 0,5 10 260455 CT MAX 800 SELV 2CSG226045R1101 0,37 1

1000 0,5 10 260554 CT MAX 1000 SELV 2CSG226055R1101 0,37 1

Overall dimensions

A B C D E F G H L

CT MAX …/5A 70 107 111 69 32 12 30 15 42

Accessories supplied:– Sealed terminals cover– Mounting accessory– M5 self-threading screw– Accessories and screws

for wall mounting

CT MAX seriesThrough primary max section [mm]

cable 30

horizontal bar 30x15 40x10

vertical bar –

13334_Trasf_Amp_CT_ENG_DEF.indd 13 15/04/14 17.05

A

B CF GØ

E

D

12 | CT Current transformers

CT PRO XT, CT PRO XT SELVOrder codes

CT PRO XTThe CT PRO XT current transformers range is designed for distribution systems using cables up to 18 mm in diameter, and primary busbars with dimensions up to 20 x 10 mm. Order codes are available with primary rated current up to 400 A. CT PRO XT transformers are the ideal solution for distribution and sub-distribution switchboards downstream ABB modular circuit-breakers (SN201, S 200, S 280, S 800, DS 201, DS 202C, DS 941) or downstream of Tmax circuit-break-ers (XT1, XT2, XT3, XT4 and T4320).

CT PRO XT …/5 A series, through primary

Primary ratedcurrent IprimA

Accurancyclass

Rated power

VA

Bbn8012542EAN

Order details Price1 piece

Weight1 piecekg

Packunitpc.Type code Order code

40 3 2 257455 CT PRO XT 40 2CSG225745R1101 0.32 1

50 3 2 257554 CT PRO XT 50 2CSG225755R1101 0.32 1

60 3 2 257653 CT PRO XT 60 2CSG225765R1101 0.32 1

80 3 2 257752 CT PRO XT 80 2CSG225775R1101 0.32 1

100 1 3 257851 CT PRO XT 100 2CSG225785R1101 0.32 1

150 1 5 257950 CT PRO XT 150 2CSG225795R1101 0.32 1

200 1 5 258056 CT PRO XT 200 2CSG225805R1101 0.32 1

250 0.5 5 258155 CT PRO XT 250 2CSG225815R1101 0.32 1

300 0.5 5 258155 CT PRO XT 300 2CSG225825R1101 0.32 1

400 0.5 5 258353 CT PRO XT 400 2CSG225835R1101 0.32 1

CT PRO XT SELV …/5 series, through primary

40 3 2 258452 CT PRO XT 40 SELV 2CSG225845R1101 0.37 1

50 3 2 258551 CT PRO XT 50 SELV 2CSG225855R1101 0.37 1

60 3 2 258650 CT PRO XT 60 SELV 2CSG225865R1101 0.37 1

80 3 2 258650 CT PRO XT 80 SELV 2CSG225875R1101 0.37 1

100 1 3 258858 CT PRO XT 100 SELV 2CSG225885R1101 0.37 1

150 1 5 258957 CT PRO XT 150 SELV 2CSG225895R1101 0.37 1

200 1 5 259053 CT PRO XT 200 SELV 2CSG225905R1101 0.37 1

250 0.5 5 259152 CT PRO XT 250 SELV 2CSG225915R1101 0.37 1

300 0.5 5 259251 CT PRO XT 300 SELV 2CSG225925R1101 0.37 1

400 0.5 5 259350 CT PRO XT 400 SELV 2CSG225935R1101 0.37 1

Overall dimensions

A B C D E F G

CT PRO XT …/5A 45 92 96 69 22 12 18

Accessories supplied:– Sealed terminals cover– Mounting accessory– M5 self-threading screw

CT PRO XT seriesThrough primary max section [mm]

cable 18

horizontal bar 20x10

vertical bar –

13334_Trasf_Amp_CT_ENG_DEF.indd 12 15/04/14 17.05

Page 52: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

52 Line Protection Equipment 0115 ABB Low Voltage 53 Line Protection Equipment 0115 ABB Low Voltage

The CT PRO XT current transformers range is designed for distribution systems using cables up to 18 mm in diameter, and primary busbars with dimensions up to 20 x 10 mm. Order codes are available with primary rated current up to 400 A. CT PRO XT transformers are the ideal solution for distribution and sub-distribution switchboards downstream ABB modular circuit-breakers (SN201, S 200, S 280, S 800, DS 201, DS 202C, DS 941) or downstream of Tmax circuit-breakers (XT1, XT2, XT3, XT4 and T4320).

CT PRO XT …/5 A series, through primary

Primary rated current Iprim A

Product Hierarchy 2500003 Order CodeAccuracy Class

Rated powerVA Part No

40 3 2 CT PRO XT 40 2CSG225745R1101

50 3 2 CT PRO XT 50 2CSG225755R1101

60 3 2 CT PRO XT 60 2CSG225765R1101

80 3 2 CT PRO XT 80 2CSG225775R1101

100 1 3 CT PRO XT 100 2CSG225785R1101

150 1 5 CT PRO XT 150 2CSG225795R1101

200 1 5 CT PRO XT 200 2CSG225805R1101

250 0.5 5 CT PRO XT 250 2CSG225815R1101

300 0.5 5 CT PRO XT 300 2CSG225825R1101

400 0.5 5 CT PRO XT 400 2CSG225835R1101

CT PRO XT SELV …/5 series, through primary40 3 2 CT PRO XT 40 SELV 2CSG225845R1101

50 3 2 CT PRO XT 50 SELV 2CSG225855R1101

60 3 2 CT PRO XT 60 SELV 2CSG225865R1101

80 3 2 CT PRO XT 80 SELV 2CSG225875R1101

100 1 3 CT PRO XT 100 SELV 2CSG225885R1101

150 1 5 CT PRO XT 150 SELV 2CSG225895R1101

200 1 5 CT PRO XT 200 SELV 2CSG225905R1101

250 0.5 5 CT PRO XT 250 SELV 2CSG225915R1101

300 0.5 5 CT PRO XT 300 SELV 2CSG225925R1101

400 0.5 5 CT PRO XT 400 SELV 2CSG225935R1101

The CT MAX current transformer range founds its main application in distribution systems with 30x10 mm and 40x10 mm horizontal primary busbars and primary rated current from 300 up to 1000 A. A primary cable up to 30 mm in diameter can also be used. CT MAX transformers are the ideal solution for applications downstream ABB Tmax T5 and T6 circuit-breakers

CT MAX …/5 A series, through primary

Primary rated current IprimA

Product Hierarchy 2500003 Order CodeAccuracy Class

Rated powerVA Part No

300 0.5 4 CT MAX 300 2CSG225945R1101

400 0.5 5 CT MAX 400 2CSG225955R1101

500 0.5 6 CT MAX 500 2CSG225965R1101

600 0.5 10 CT MAX 600 2CSG225975R1101

800 0.5 10 CT MAX 800 2CSG225985R1101

1000 0.5 10 CT MAX 1000 2CSG225995R1101

CT MAX SELV …/5 series, through primary300 0.5 4 CT MAX 300 SELV 2CSG226005R1101

400 0.5 5 CT MAX 400 SELV 2CSG226015R1101

500 0.5 6 CT MAX 500 SELV 2CSG226025R1101

600 0.5 10 CT MAX 600 SELV 2CSG226035R1101

800 0.5 10 CT MAX 800 SELV 2CSG226045R1101

1000 0.5 10 CT MAX 1000 SELV 2CSG226055R1101

CT Current transformersCT PRO XT, CT PRO XT SELV & CT MAX, CT MAX SELV

A

B CF GØ

E

D

12 | CT Current transformers

CT PRO XT, CT PRO XT SELVOrder codes

CT PRO XTThe CT PRO XT current transformers range is designed for distribution systems using cables up to 18 mm in diameter, and primary busbars with dimensions up to 20 x 10 mm. Order codes are available with primary rated current up to 400 A. CT PRO XT transformers are the ideal solution for distribution and sub-distribution switchboards downstream ABB modular circuit-breakers (SN201, S 200, S 280, S 800, DS 201, DS 202C, DS 941) or downstream of Tmax circuit-break-ers (XT1, XT2, XT3, XT4 and T4320).

CT PRO XT …/5 A series, through primary

Primary ratedcurrent IprimA

Accurancyclass

Rated power

VA

Bbn8012542EAN

Order details Price1 piece

Weight1 piecekg

Packunitpc.Type code Order code

40 3 2 257455 CT PRO XT 40 2CSG225745R1101 0.32 1

50 3 2 257554 CT PRO XT 50 2CSG225755R1101 0.32 1

60 3 2 257653 CT PRO XT 60 2CSG225765R1101 0.32 1

80 3 2 257752 CT PRO XT 80 2CSG225775R1101 0.32 1

100 1 3 257851 CT PRO XT 100 2CSG225785R1101 0.32 1

150 1 5 257950 CT PRO XT 150 2CSG225795R1101 0.32 1

200 1 5 258056 CT PRO XT 200 2CSG225805R1101 0.32 1

250 0.5 5 258155 CT PRO XT 250 2CSG225815R1101 0.32 1

300 0.5 5 258155 CT PRO XT 300 2CSG225825R1101 0.32 1

400 0.5 5 258353 CT PRO XT 400 2CSG225835R1101 0.32 1

CT PRO XT SELV …/5 series, through primary

40 3 2 258452 CT PRO XT 40 SELV 2CSG225845R1101 0.37 1

50 3 2 258551 CT PRO XT 50 SELV 2CSG225855R1101 0.37 1

60 3 2 258650 CT PRO XT 60 SELV 2CSG225865R1101 0.37 1

80 3 2 258650 CT PRO XT 80 SELV 2CSG225875R1101 0.37 1

100 1 3 258858 CT PRO XT 100 SELV 2CSG225885R1101 0.37 1

150 1 5 258957 CT PRO XT 150 SELV 2CSG225895R1101 0.37 1

200 1 5 259053 CT PRO XT 200 SELV 2CSG225905R1101 0.37 1

250 0.5 5 259152 CT PRO XT 250 SELV 2CSG225915R1101 0.37 1

300 0.5 5 259251 CT PRO XT 300 SELV 2CSG225925R1101 0.37 1

400 0.5 5 259350 CT PRO XT 400 SELV 2CSG225935R1101 0.37 1

Overall dimensions

A B C D E F G

CT PRO XT …/5A 45 92 96 69 22 12 18

Accessories supplied:– Sealed terminals cover– Mounting accessory– M5 self-threading screw

CT PRO XT seriesThrough primary max section [mm]

cable 18

horizontal bar 20x10

vertical bar –

13334_Trasf_Amp_CT_ENG_DEF.indd 12 15/04/14 17.05

A

BCF HGØ

E

L

D

CT Current transformers | 13

CT MAX, CT MAX SELVOrder codes

CT MAXThe CT MAX current transformer range founds its main application in distribution systems with 30x10 mm and 40x10 mm horizontal primary busbars and primary rated current from 300 up to 1000 A. A primary cable up to 30 mm in diameter can also be used. CT MAX transformers are the ideal solution for applications downstream ABB Tmax T5 and T6 circuit-breakers.

CT MAX …/5 A series, through primary

Primary ratedcurrent IprimA

Accurancyclass

Rated power

VA

Bbn8012542EAN

Order details Price1 piece

Weight1 piecekg

Packunitpc.Type code Order code

300 0,5 4 259459 CT MAX 300 2CSG225945R1101 0,32 1

400 0,5 5 259558 CT MAX 400 2CSG225955R1101 0,32 1

500 0,5 6 259558 CT MAX 500 2CSG225965R1101 0,32 1

600 0,5 10 259657 CT MAX 600 2CSG225975R1101 0,32 1

800 0,5 10 259657 CT MAX 800 2CSG225985R1101 0,32 1

1000 0,5 10 259954 CT MAX 1000 2CSG225995R1101 0,32 1

CT MAX SELV …/5 series, through primary

300 0,5 4 260059 CT MAX 300 SELV 2CSG226005R1101 0,37 1

400 0,5 5 260158 CT MAX 400 SELV 2CSG226015R1101 0,37 1

500 0,5 6 260257 CT MAX 500 SELV 2CSG226025R1101 0,37 1

600 0,5 10 260356 CT MAX 600 SELV 2CSG226035R1101 0,37 1

800 0,5 10 260455 CT MAX 800 SELV 2CSG226045R1101 0,37 1

1000 0,5 10 260554 CT MAX 1000 SELV 2CSG226055R1101 0,37 1

Overall dimensions

A B C D E F G H L

CT MAX …/5A 70 107 111 69 32 12 30 15 42

Accessories supplied:– Sealed terminals cover– Mounting accessory– M5 self-threading screw– Accessories and screws

for wall mounting

CT MAX seriesThrough primary max section [mm]

cable 30

horizontal bar 30x15 40x10

vertical bar –

13334_Trasf_Amp_CT_ENG_DEF.indd 13 15/04/14 17.05

Accessories supplied:– Sealed terminals cover– Mounting accessory– M5 self-threading screw

Accessories supplied:– Sealed terminals cover– Mounting accessory– M5 self-threading screw– Accessories and screws for wall mounting

Page 53: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

52 Line Protection Equipment 0115 ABB Low Voltage 53 Line Protection Equipment 0115 ABB Low Voltage

Electronic Systems Protection | Design & technical solut ions 3

Electronic Systems ProtectionSurge Protection now included in BS 7671

Amendment 1 of BS 7671, effective from 1st January 2012, requires all electrical system designs and installations to be assessed against risk of transient overvoltages of atmospheric origin, or from switching events, in line with its Sections 443 & 534. Section 443 defines the criteria for risk assessment, whereas Section 534 describes the selection and installation of suitable Surge Protective Devices (SPDs), where required, for effective transient overvoltage protection.

Why is transient overvoltage protection so important?Transient overvoltages are short duration surges in voltage between two or more conductors (L-PE, L-N or N-PE), which can reach up to 6 kV on 230 Vac power lines, and generally result from:

Atmospheric origin (lightning activity) through resistive (see Figure 2) or inductive coupling and/or Electrical switching of inductive loads.

Transient overvoltages significantly damage and degrade electronic systems.

Outright damage to sensitive electronic systems, such as computers etc, occurs when transient overvoltages between L-PE or N-PE exceed the withstand voltage of the electrical equipment (i.e. above 1.5 kV for Category I equipment to BS 7671 Tables 44.3 & 44.4).

Equipment damage leads to unexpected failures and expensive downtime, or risk of fire/electric shock due to flashover, if insulation breaks down.

> 1.5 kV (L-PE/N-PE)

> 2x peak operating voltage(e.g. 715 V L-N)

Nominal system voltage (e.g. 230 V)

Safe Operating Area

Degradation

DAMAGE

Safe Operating Area

Degradation

Degradation

DAMAGE

DAMAGE

The latest amendment to the IET Wiring Regulations 17th Edition (BS 7671) brings into sharp focus the need to protect sensitive and critical electronic systems against transient overvoltages (surges).

Figure 2: Resistive coupling Figure 3: Equipment risk

> 1.5 kV (L-PE/N-PE)

> 2x peak operating voltage(e.g. 715 V L-N)

Nominal system voltage (e.g. 230 V)

Safe Operating Area

Degradation

DAMAGE

Safe Operating Area

Degradation

Degradation

DAMAGE

DAMAGE

For protection measures against direct lightning strikes, and against transient overvoltages on additional metallic servicelines (e.g. data, signal & telecoms), BS 7671 refers to BS EN 62305 (534.1 NOTE 2).

Full protection of electronic systems can only be achieved if all incoming/outgoing metallic services, including data, signal and telecoms lines are protected.

Protect additional metallic services

IMPORTANT: Equipment is ONLY protected against transient overvoltages if all incoming / outgoing mains and data lines have protection fitted.

Data/Telecom

Power

Electronic Systems Protection | Design & technical solut ions 3

Electronic Systems ProtectionSurge Protection now included in BS 7671

Amendment 1 of BS 7671, effective from 1st January 2012, requires all electrical system designs and installations to be assessed against risk of transient overvoltages of atmospheric origin, or from switching events, in line with its Sections 443 & 534. Section 443 defines the criteria for risk assessment, whereas Section 534 describes the selection and installation of suitable Surge Protective Devices (SPDs), where required, for effective transient overvoltage protection.

Why is transient overvoltage protection so important?Transient overvoltages are short duration surges in voltage between two or more conductors (L-PE, L-N or N-PE), which can reach up to 6 kV on 230 Vac power lines, and generally result from:

Atmospheric origin (lightning activity) through resistive (see Figure 2) or inductive coupling and/or Electrical switching of inductive loads.

Transient overvoltages significantly damage and degrade electronic systems.

Outright damage to sensitive electronic systems, such as computers etc, occurs when transient overvoltages between L-PE or N-PE exceed the withstand voltage of the electrical equipment (i.e. above 1.5 kV for Category I equipment to BS 7671 Tables 44.3 & 44.4).

Equipment damage leads to unexpected failures and expensive downtime, or risk of fire/electric shock due to flashover, if insulation breaks down.

> 1.5 kV (L-PE/N-PE)

> 2x peak operating voltage(e.g. 715 V L-N)

Nominal system voltage (e.g. 230 V)

Safe Operating Area

Degradation

DAMAGE

Safe Operating Area

Degradation

Degradation

DAMAGE

DAMAGE

The latest amendment to the IET Wiring Regulations 17th Edition (BS 7671) brings into sharp focus the need to protect sensitive and critical electronic systems against transient overvoltages (surges).

Figure 2: Resistive coupling Figure 3: Equipment risk

> 1.5 kV (L-PE/N-PE)

> 2x peak operating voltage(e.g. 715 V L-N)

Nominal system voltage (e.g. 230 V)

Safe Operating Area

Degradation

DAMAGE

Safe Operating Area

Degradation

Degradation

DAMAGE

DAMAGE

For protection measures against direct lightning strikes, and against transient overvoltages on additional metallic servicelines (e.g. data, signal & telecoms), BS 7671 refers to BS EN 62305 (534.1 NOTE 2).

Full protection of electronic systems can only be achieved if all incoming/outgoing metallic services, including data, signal and telecoms lines are protected.

Protect additional metallic services

IMPORTANT: Equipment is ONLY protected against transient overvoltages if all incoming / outgoing mains and data lines have protection fitted.

Data/Telecom

Power

Electronic Systems Protection | Design & technical solut ions 3

Electronic Systems ProtectionSurge Protection now included in BS 7671

Amendment 1 of BS 7671, effective from 1st January 2012, requires all electrical system designs and installations to be assessed against risk of transient overvoltages of atmospheric origin, or from switching events, in line with its Sections 443 & 534. Section 443 defines the criteria for risk assessment, whereas Section 534 describes the selection and installation of suitable Surge Protective Devices (SPDs), where required, for effective transient overvoltage protection.

Why is transient overvoltage protection so important?Transient overvoltages are short duration surges in voltage between two or more conductors (L-PE, L-N or N-PE), which can reach up to 6 kV on 230 Vac power lines, and generally result from:

Atmospheric origin (lightning activity) through resistive (see Figure 2) or inductive coupling and/or Electrical switching of inductive loads.

Transient overvoltages significantly damage and degrade electronic systems.

Outright damage to sensitive electronic systems, such as computers etc, occurs when transient overvoltages between L-PE or N-PE exceed the withstand voltage of the electrical equipment (i.e. above 1.5 kV for Category I equipment to BS 7671 Tables 44.3 & 44.4).

Equipment damage leads to unexpected failures and expensive downtime, or risk of fire/electric shock due to flashover, if insulation breaks down.

> 1.5 kV (L-PE/N-PE)

> 2x peak operating voltage(e.g. 715 V L-N)

Nominal system voltage (e.g. 230 V)

Safe Operating Area

Degradation

DAMAGE

Safe Operating Area

Degradation

Degradation

DAMAGE

DAMAGE

The latest amendment to the IET Wiring Regulations 17th Edition (BS 7671) brings into sharp focus the need to protect sensitive and critical electronic systems against transient overvoltages (surges).

Figure 2: Resistive coupling Figure 3: Equipment risk

> 1.5 kV (L-PE/N-PE)

> 2x peak operating voltage(e.g. 715 V L-N)

Nominal system voltage (e.g. 230 V)

Safe Operating Area

Degradation

DAMAGE

Safe Operating Area

Degradation

Degradation

DAMAGE

DAMAGE

For protection measures against direct lightning strikes, and against transient overvoltages on additional metallic servicelines (e.g. data, signal & telecoms), BS 7671 refers to BS EN 62305 (534.1 NOTE 2).

Full protection of electronic systems can only be achieved if all incoming/outgoing metallic services, including data, signal and telecoms lines are protected.

Protect additional metallic services

IMPORTANT: Equipment is ONLY protected against transient overvoltages if all incoming / outgoing mains and data lines have protection fitted.

Data/Telecom

Power

The latest amendment to the IET Wiring Regulations 17th Edition (BS 7671) brings into sharp focus the need to protect sensitive and critical electronic systems against transient overvoltages (surges).

Amendment 1 of BS 7671, effective from 1st January 2012,requires all electrical system designs and installations to beassessed against risk of transient overvoltages of atmosphericorigin, or from switching events, in line with its Sections 443 &534. Section 443 defines the criteria for risk assessment,whereas Section 534 describes the selection and installationof suitable Surge Protective Devices (SPDs), where required,for effective transient overvoltage protection.Transient overvoltages are short duration surges in voltagebetween two or more conductors (L-PE, L-N or N-PE), whichcan reach up to 6 kV on 230 Vac power lines, and generallyresult from:Transient overvoltages significantly damage and degradeelectronic systems.Outright damage to sensitive electronic systems, such ascomputers etc, occurs when transient overvoltages betweenL-PE or N-PE exceed the withstand voltage of the electricalequipment (i.e. above 1.5 kV for Category I equipment to BS7671 Tables 44.3 & 44.4).

For protection measures against direct lightning strikes, andagainst transient overvoltages on additional metallic servicelines (e.g. data, signal & telecoms), BS 7671 refers toBS EN 62305 (534.1 NOTE 2).Full protection of electronic systems can only be achieved ifall incoming/outgoing metallic services, including data, signaland telecoms lines are protected

Protect additional metallic servicesIMPORTANT:Equipment is ONLY protectedagainst transient overvoltagesif all incoming / outgoing mainsand data lines have protectionfitted.

Surge protection systemsSurge protective devices to BS7671

Page 54: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

54 Line Protection Equipment 0115 ABB Low Voltage 55 Line Protection Equipment 0115 ABB Low Voltage

Surge protection systemsEnhanced Solutions to BS EN 62305 / BS 7671

Furse Surge Protective Devices are widely specified and offer industry-leading voltage protection levels to ensure thecontinuous operation of critical electronic systems, such as those found in data centres, hospitals and automated processcontrol. Used with Furse data / telecom SPDs, they form part of a complete lightning protection solution.

4 Electronic Systems Protection | Design & technical solut ions

Furse Electronic Systems ProtectionEnhanced Solutions to BS EN 62305 / BS 7671

Protection for 230/400 V TN-S or TN-C-S supplies

Protection for data signal and telecoms applications

– No external lightning protection system fitted

– Underground mains supply feed

– No external lightning protection system fitted

– Exposed overhead mains supply feed

– External lightning protection system fitted

– Multiple connected metallic services

– External lightning protection system fitted

– No. of services unknown

For LPL I & IIESP 415/I/TNSorESP 415 M4(for electronicslocated nearMDB before SDB)

ESP 415 D1 Series

ESP 415/III/TNS

ESP 415 D1 Series

For LPL III & IVESP 415/III/TNSorESP 415 M2(for electronicslocated nearMDB before SDB)

3 Phase 400 VService entrance,after electricitymeter (Maindistribution board (MDB)

3 Phase 400 V1 Phase 230 VSub-distributionboard (SDB) located> 10 m fromMDB feedingelectronicequipment

Critical terminalequipmentlocated > 10 mfrom SDB

ESP 415 M1 Series

ESP 415 M2 Series(for electronicslocated nearMDB before SDB)

For 3 Phase 400 V:ESP 415 D1 Series, orESP 415 M1 Series

For 1 Phase 230 V:ESP 240 D1 Series, orESP 240 M1 Series

OR

OR

OR

OR

OR

OR

ESP 415 M1 Series

Protection for 230/400 V TN‐S or TN‐C‐S supplies

ESP MCESP MC/TN/RJ11 (e.g. for fax machines)ESP MC/Cat‐5e (e.g. for servers)

oror

Ground Level

Power

Power

Ground Level

LPS

PowerDataTelecomWaterGas

Ground Level

LPS

Power

Unknown

Ground Level

No external lightning protection system fittedUnderground mains supply feed

No external lightning protection system fittedExposed overhead mains supply feed

External lightning protection system fittedMultiple connected metallic services

External lightning protection system fittedNo. of services unknown

ESP 415 D1 Series ESP 415 M1 Series ESP 415 M1 SeriesESP 415 D1 Series For LPL III & IVESP 415/III/TNSorESP 415 M2(for electronics located near MDB before SDB)

ESP 415/III/TNS ESP 415 M2 Series(for electronics located near MDB before SDB)

For LPL I & IIESP 415/I/TNSorESP 415 M4(for electronics located near MDB before SDB)

orororor

3 Phase 400 V

Service entrance, after electricitymeter (Maindistribution board (MDB)

3 Phase 400 V1 Phase 230 V

Sub‐distributionboard (SDB) ‐located > 10 m from MDB feedingelectronicequipment

Critical terminalequipment ‐located > 10 mfrom SDB

For 3 Phase 400 V: ESP 415 D1 Series, or ESP 415 M1 Series

For 1 Phase 230 V: ESP 240 D1 Series, or ESP 240 M1 Series

Protection for 230/400 V TN‐S or TN‐C‐S supplies

ESP MCESP MC/TN/RJ11 (e.g. for fax machines)ESP MC/Cat‐5e (e.g. for servers)

oror

Ground Level

Power

Power

Ground Level

LPS

PowerDataTelecomWaterGas

Ground Level

LPS

Power

Unknown

Ground Level

No external lightning protection system fittedUnderground mains supply feed

No external lightning protection system fittedExposed overhead mains supply feed

External lightning protection system fittedMultiple connected metallic services

External lightning protection system fittedNo. of services unknown

ESP 415 D1 Series ESP 415 M1 Series ESP 415 M1 SeriesESP 415 D1 Series For LPL III & IVESP 415/III/TNSorESP 415 M2(for electronics located near MDB before SDB)

ESP 415/III/TNS ESP 415 M2 Series(for electronics located near MDB before SDB)

For LPL I & IIESP 415/I/TNSorESP 415 M4(for electronics located near MDB before SDB)

orororor

3 Phase 400 V

Service entrance, after electricitymeter (Maindistribution board (MDB)

3 Phase 400 V1 Phase 230 V

Sub‐distributionboard (SDB) ‐located > 10 m from MDB feedingelectronicequipment

Critical terminalequipment ‐located > 10 mfrom SDB

For 3 Phase 400 V: ESP 415 D1 Series, or ESP 415 M1 Series

For 1 Phase 230 V: ESP 240 D1 Series, or ESP 240 M1 Series

Protection for 230/400 V TN‐S or TN‐C‐S supplies

ESP MCESP MC/TN/RJ11 (e.g. for fax machines)ESP MC/Cat‐5e (e.g. for servers)

oror

Ground Level

Power

Power

Ground Level

LPS

PowerDataTelecomWaterGas

Ground Level

LPS

Power

Unknown

Ground Level

No external lightning protection system fittedUnderground mains supply feed

No external lightning protection system fittedExposed overhead mains supply feed

External lightning protection system fittedMultiple connected metallic services

External lightning protection system fittedNo. of services unknown

ESP 415 D1 Series ESP 415 M1 Series ESP 415 M1 SeriesESP 415 D1 Series For LPL III & IVESP 415/III/TNSorESP 415 M2(for electronics located near MDB before SDB)

ESP 415/III/TNS ESP 415 M2 Series(for electronics located near MDB before SDB)

For LPL I & IIESP 415/I/TNSorESP 415 M4(for electronics located near MDB before SDB)

orororor

3 Phase 400 V

Service entrance, after electricitymeter (Maindistribution board (MDB)

3 Phase 400 V1 Phase 230 V

Sub‐distributionboard (SDB) ‐located > 10 m from MDB feedingelectronicequipment

Critical terminalequipment ‐located > 10 mfrom SDB

For 3 Phase 400 V: ESP 415 D1 Series, or ESP 415 M1 Series

For 1 Phase 230 V: ESP 240 D1 Series, or ESP 240 M1 Series

Protection for 230/400 V TN‐S or TN‐C‐S supplies

ESP MCESP MC/TN/RJ11 (e.g. for fax machines)ESP MC/Cat‐5e (e.g. for servers)

oror

Ground Level

Power

Power

Ground Level

LPS

PowerDataTelecomWaterGas

Ground Level

LPS

Power

Unknown

Ground Level

No external lightning protection system fittedUnderground mains supply feed

No external lightning protection system fittedExposed overhead mains supply feed

External lightning protection system fittedMultiple connected metallic services

External lightning protection system fittedNo. of services unknown

ESP 415 D1 Series ESP 415 M1 Series ESP 415 M1 SeriesESP 415 D1 Series For LPL III & IVESP 415/III/TNSorESP 415 M2(for electronics located near MDB before SDB)

ESP 415/III/TNS ESP 415 M2 Series(for electronics located near MDB before SDB)

For LPL I & IIESP 415/I/TNSorESP 415 M4(for electronics located near MDB before SDB)

orororor

3 Phase 400 V

Service entrance, after electricitymeter (Maindistribution board (MDB)

3 Phase 400 V1 Phase 230 V

Sub‐distributionboard (SDB) ‐located > 10 m from MDB feedingelectronicequipment

Critical terminalequipment ‐located > 10 mfrom SDB

For 3 Phase 400 V: ESP 415 D1 Series, or ESP 415 M1 Series

For 1 Phase 230 V: ESP 240 D1 Series, or ESP 240 M1 Series

ESP MCESP MC/TN/RJ11 (e.g. for fax machines)ESP MC/Cat-5e (e.g. for servers)

Furse Surge Protective Devices are widely specified and offer industry-leading voltage protection levels to ensure the continuous operation of critical electronic systems, such as those found in data centres, hospitals and automated process control. Used with Furse data / telecom SPDs, they form part of a complete lightning protection solution.

GroundLevel

GroundLevel

PowerDataTelecomWaterGas

Power Power

Unknown

LPS LPS

GroundLevel

Power

- No external lightning protection system fitted- Underground mains supply feed

- No external lightning protection system fitted- Exposed overhead mains supply feed

- No external lightning protection system fitted- Multiple connected metallic services

- External lightning protection system fitted- No. of services unknown

Protection for 230/400 V TN-S or TN-C-S supplies

Protection for data signal and telecoms applications

OR OR OR OR

OR OR

Page 55: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

54 Line Protection Equipment 0115 ABB Low Voltage 55 Line Protection Equipment 0115 ABB Low Voltage

ABB LV panel SPDsCommercial, industrial & domestic installations

Main section boardType 1+2 ABB surge protective devices have a high impulse current(10/350 waveform) withstand capacity whilst ensuring a low (better)voltage protection level (Up).- Multi-mode protection- End of life SPD visual indicator- DIN rail mounting for quick installation- Compact design

Product Hierarchy 600002 Order Code

Surge protective device – TNS/TT 230/400V OVR T1+2 3N 15-255-7

Sub distribution board Type 2 surge protective devices are designed to protect electricalinstallations and sensitive equipment against indirect surge currents- Multi-mode protection- End of life SPD visual indicator- Plug-in cartridge- DIN rail mounting for quick installation- Auxiliary contact TS for remote status indication

Surge protective device - TNS/TT 230/400V 3Ph+N networks OVR T2 3N 40 275s P TS

Sub distribution board Self-protected with integral backup miniature circuit breaker offeringdedicated over current protection device (OCPD) fully coordinated withthe surge protective device.- Multi-mode protection- DIN rail mounting for quick installation- High reliability- Innovative, weld-free safe thermal disconnection sensor - Fully compatible with the complete ABB pro M modular range

Self-protected surge protective device - TNS/TT 230V/400V 3Ph+N networks OVR Plus N3 40

Consumer units – Domestic/Residential Self-protected with integral backup miniature circuit breaker offeringdedicated over current protection device (OCPD) fully coordinated withthe surge protective device.- Multi-mode protection- DIN rail mounting for quick installation- Fully coordinated unit for optimised installation and simplified wiring- High reliability- Innovative, weld-free safe thermal disconnection sensor- Compact design

Self-protected surge protective device - TNS/TT 230 V 1Ph+N networks OVR Plus N1 20

Electronic Systems Protection | Design & technical solut ions 5

Main section boardOVR T1+2 3N 15-255-7 surge protective device – TNS/TT 230/400V 3Ph+N networksType 1+2 ABB surge protective devices have a high impulse current (10/350 waveform) withstand capacity whilst ensuring a low (better) voltage protection level (Up).

Consumer units – Domestic/ResidentialOVR Plus N1 20 self-protected surge protective device - TNS/TT 230 V 1Ph+N networksSelf-protected with integral backup miniature circuit breaker offering dedicated over current protection device (OCPD) fully coordinated with the surge protective device.

Sub-distribution boardOVR T2 3N 40 275s P TS surge protective device - TNS/TT 230/400V 3Ph+N networksType 2 surge protective devices are designed to protect electrical installations and sensitive equipment against indirect surge currents

OVR Plus N3 40 self-protected surge protective device - TNS/TT 230V/400V 3Ph+N networksSelf-protected with integral backup miniature circuit breaker offering dedicated over current protection device (OCPD) fully coordinated with the surge protective device.

28 | ABB System pro M compact®

3

DescriptionType 1 and Type 1+2 surge protective devices are designed to discharge high current surges without any de-struction of the installation. These surge protective devices are characterized by their capacity to withstand impulse current with 10/350 µs wave form which simulate natural lightning current.

Type 1+2 ABB surge protective devices have a high impulse current withstand capacity with ensuring a low protection level (Up).

Type 1 and Type 1+2 SPDs can be installed at the entrance in the main switch board for a global protection of the electrical installation.

Ordering detailsNb of poles

Impulse current

Follow current interrupting rating

Voltage protection level

Nominal voltage

Max. cont. operating voltage

Type Order code EAN code

Weight

Pkg(1 pce)Iimp

10/350 Ifi Up Un UckA kA kV V V 3660308 kg

Follow current interrupting rating 50 kA4 25 50 2.5 230/400 255 OVR T1 4L 25-255 2CTB815101R1400 510914 1.164 25 50 2.5 230/400 255 OVR T1 4L 25-255 TS 2CTB815101R0800 510969 1.263+1 25 50 2.5 230/400 255 OVR T1 3N 25-255 2CTB815101R1600 510938 1.163+1 25 50 2.5 230/400 255 OVR T1 3N 25-255 TS 2CTB815101R0700 510983 1.26

Follow current interrupting rating 7 kA3+1 25 7 2.5 230/400 255 OVR T1 3N 25-255-7 2CTB815101R8800 514127 0.84

OVR Type 1 surge protective devicesTNS/TT 230 V 3Ph+N networks

OVR T1 3N 25-255-7

Type Width

mm inchesOVR T1 4L 25-255 140.0 5.5OVR T1 4L 25-255 TS 157.5 6.2OVR T1 3N 25-255 140.0 5.6OVR T1 3N 25-255 TS 157.5 6.3OVR T1 3N 25-255-7 89.0 3.5

Main dimensions mm

140 157.5

OVR T1 4L 25-255OVR T1 3N 25-255

OVR T1 3N 25-255-7

OVR T1 4L 25-255 TS OVR T1 3N 25-255 TS

56 | ABB System pro M compact®

OVR T2 3N 15-275 P

Type Width

mm inchesOVR T2 3N 15-275 P 71.2 2.80OVR T2 3N 40-275 P 71.2 2.80OVR T2 3N 40-275 P TS 71.2 2.80OVR T2 3N 40-275s P 71.2 2.80OVR T2 3N 40-275s P TS 71.2 2.80OVR T2 3N 70-275s P 71.2 2.80OVR T2 3N 70-275s P TS 71.2 2.80

OVR T2 3N 40-275 P TS OVR T2 3N 40-275s P TS OVR T2 3N 70-275s P TS

OVR T2 3N 15-275 P OVR T2 3N 40-275 P OVR T2 3N 40-275s P OVR T2 3N 70-275s P

Main dimensions mm

3

DescriptionType 2 surge protective devices are designed to protect electric installations and sensitive equipment against indirect surges with ensuring a low protection level (Up). They are characterized by their capacity to safely discharge current with 8/20 µs wave form.

Ordering detailsNb of poles

Max. discharge current

Nominal discharge current

Voltage protection level

Nominal voltage

Max. cont. operating voltage

Type Order code EAN code

Weight

Pkg(1 pce)Imax

8/20 In Up Un Uc

kA kA kV V V 3660308 kg

Type 2 pluggable - Uc 275 V3+1 15 5 1.0 230/400 275 OVR T2 3N 15-275 P 2CTB803953R1200 513151 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275 P 2CTB803953R1100 513267 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275 P TS 2CTB803953R0500 514394 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275s P 2CTB803953R0800 513144 0.453+1 40 20 1.4 230/400 275 OVR T2 3N 40-275s P TS 2CTB803953R0200 513120 0.453+1 70 30 1.5 230/400 275 OVR T2 3N 70-275s P 2CTB803953R0700 513137 0.453+1 70 30 1.5 230/400 275 OVR T2 3N 70-275s P TS 2CTB803953R0100 513113 0.45

OVR Type 2 surge protective devicesTNS/TT 230 V 3Ph+N networks

62 | ABB System pro M compact®

OVR PLUS N3 20OVR PLUS N3 40

Type Width

mm inchesOVR PLUS N1 20 35.6 1.40OVR PLUS N1 40 35.6 1.40OVR PLUS N3 20 106.8 4.20OVR PLUS N3 40 106.8 4.20

OVR Plus N3 20OVR Plus N3 40

OVR Plus N1 20OVR Plus N1 40

3

DescriptionOVR PLUS N3 20 and OVR PLUS N3 40 for commercial and industrial applications: – Auto-protected: Backup miniature circuit breaker integrated and fully coordinated with the surge protective device.

– Easy installation: Fully coordinated unit with easy wiring with the complete ABB pro M modular range. – High discharge capacity: With Imax 20 and 40 kA the OVR Plus N3 insure the protection of your low voltage installations and electric equipment.

– High reliability: No welding inside the module and specific thermal disconnection with the "bilame" sensor.

OVR PLUS N1 40 for residential applications: – Auto-protected: Backup miniature circuit breaker integrated and fully coordinated with the surge protective device.

– Compact: Only two modules (36 mm width), means more space and easy wiring with the complete ABB DIN rail range.

– High discharge capacity: With Imax 20 and 40 kA the OVR PLUS N1 can protect your electric equipment against high surges.

– High reliability: No welding inside the module and specific thermal disconnection.

Ordering detailsProtected lines

Max. discharge current

Nominal current

Voltage protection level

Nominal voltage

Max. cont. operating voltage

Type Order code EAN code

Weight

Pkg(1 pce)Imax

8/20 In Up Un Uc

kA kA kV V V 3660308 kg

Type 2 autoprotected1+1 20 5 1.3 230/400 275 OVR PLUS N1 20 2CTB803701R0700 521286 0.281+1 40 20 1.8 230/400 320 OVR PLUS N1 40 2CTB803701R0100 517005 0.283+1 20 5 1.3 230/400 320 OVR PLUS N3 20 2CTB803701R0400 517081 0.843+1 40 20 2.0 230/400 320 OVR PLUS N3 40 2CTB803701R0300 517074 0.84

OVR Plus - Autoprotected surge protective devicesTNS/TT 230 V networks

Main dimensions mm

– Multi-mode protection – End of life SPD visual indicator – DIN rail mounting for quick installation – Compact design

– Multi-mode protection – DIN rail mounting for quick installation – Fully coordinated unit for optimised installation and simplified wiring – High reliability – Innovative, weld-free safe thermal disconnection sensor – Compact design

– Multi-mode protection – End of life SPD visual indicator – Plug-in cartridge – DIN rail mounting for quick installation – Auxiliary contact TS for remote status indication

– Multi-mode protection – DIN rail mounting for quick installation – High reliability – Innovative, weld-free safe thermal disconnection sensor – Fully compatible with the complete ABB pro M modular range

ABB LV Panel SPDsCommercial, Industrial & Domestic Installations

ABB’s wide range of mains SPDs compliment the power DIN-rail product range, providing protection to the electrical installation at any point in the mains distribution system.

Characteristics

Characteristics

Characteristics

Characteristics

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax20 kA

OCPDINTEGRATEDMODULE

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

limp15 kA

ALARM Plug-inRES ON

TSAUXILIARYCONTACT

Imax40 kA

OCPDINTEGRATEDModule

COMPACTSPACESAVINGDESIGN

IEC 61643-11EN 61643-11

ABB’s wide range of mains SPDs compliment the power DIN-rail product range,providing protection to the electrical installation at any point in the mains distributionsystem.

COMPACTSPACESAVINGDESIGN

limp15 kA

IEC 61643-11EN 61643-11

ALARMRES ON

Imax40 kA

Plug-inModule

TSAUXILIARYCONTACT

IEC 61643-11EN 61643-11

COMPACTSPACESAVINGDESIGN

Imax40 kA

OCPDINTEGRATED

IEC 61643-11EN 61643-11

COMPACTSPACESAVINGDESIGN

Imax20 kA

OCPDINTEGRATED

IEC 61643-11EN 61643-11

Page 56: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

56 Line Protection Equipment 0115 ABB Low Voltage 57 Line Protection Equipment 0115 ABB Low Voltage

Electronic Systems Protection | Design & technical solut ions 7

Safety distanceagainst too higha magnetic field

LPZ 1SPD 0/1

Rolling sphere radius

Rolling sphere radius

Equipotentialbonding bymeans of SPD

Ground level

SPD 0/1

SPD 0/1

SPD 1/2

SPD 1/2LPZ 2

LPZ 0B

LPZ 0B LPZ 0B

LPZ 0A

Flash to thestructure

Flash nearto thestructure

Flash to a lineconnected tothe structure

S2

S1

S3

ds

dsFlash near aline connectedto the structure

S4

The general principle is that the equipment requiring protection should be located in an LPZ whose electromagnetic characteristics are compatible with the equipment stress withstand or immunity capability.

In general, the higher the number of the zone (LPZ 2; LPZ 3 etc) the lower the electromagnetic effects expected. Typically, any sensitive electronic equipment should be located in higher numbered LPZs and be protected by its relevant SPM.

Enhanced Total SolutionLightning Protection Zone (LPZ) Concept

The Lightning Protection Zone (LPZ) concept was introduced in BS EN 62305, particularly to assist in determining the Surge Protection Measures (SPM) required within a structure.

Figure 5: LPZ defined by protection measures

Enhanced Total SolutionLightning protection zone (LPZ) Concept

The Lightning Protection Zone (LPZ) concept was introduced in BS EN 62305,particularly to assist in determining the Surge Protection Measures (SPM) requiredwithin a structure.

The general principle is that the equipment requiringprotection should be located in an LPZ whoseelectromagnetic characteristics are compatible with theequipment stress withstand or immunity capability.

In general, the higher the number of the zone (LPZ 2; LPZ 3etc) the lower the electromagnetic effects expected. Typically,any sensitive electronic equipment should be located in highernumbered LPZs and be protected by its relevant SPM.

Page 57: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

56 Line Protection Equipment 0115 ABB Low Voltage 57 Line Protection Equipment 0115 ABB Low Voltage

Fusing and Installation of SPDsTransient overvoltage protection to BS 7671

Critical length of connecting conductorsAn installed SPD will always present a higher letthroughvoltage to equipment compared with the voltage protection level (Up) stated on a manufacturer’s data sheet, due to additive inductive voltage drops across the conductors on the SPD’s connecting leads.

Therefore, for maximum transient overvoltage protection the SPDs connecting conductors must be kept as short as possible.

BS 7671 Clause 534.2.9 defines that for SPDs installed in parallel (shunt), the total lead length between line conductors, protective conductor and SPD preferably should not exceed 0.5 m and never exceed 1 m. Current loops should be avoided.

For SPDs installed in-line (series), the lead length between the protective conductor and SPD preferably should not exceed 0.5 m and never exceed 1 m.

Best practice Poor installation can significantly reduce effectiveness of SPDs. Therefore, keeping connecting leads as short as possible is vital to maximize performance, and minimize additive inductive voltages.

Best practice cabling techniques, such as binding together connecting leads over as much of their length as possible, using cable ties or spiral wrap, is highly effective in cancelling inductance.

The combination of an SPD with low voltage protection level (Up), and short, tightly bound connecting leads will lead to an optimum controlled installation meeting the requirements of BS 7671.

L N

T2 C

T1 Iimp 4kAIn 20kAImax

oc

40kAU 6kV

c zacU 280V 47-63H

B

DT3

125 AgL

!

GREEN FULL PROTECTION

GREEN & RED REDUCEDPROTECTION(replace unit)

RED NO PROTECTION

WARNING: If lit / flashing disconnectunit & check Neutralto Earth voltage

EN/IEC 61643

PATENTAPPLIED

FOR STATUS INDICATIONESP 240D1

L L1 N1N

1114 12

STATUSSTATT TUSAA

OCPD

OCPD

SPD

< 0.25 m

< 0.25 mMain earthingterminal orconnectingconductor bar

Multiple terminalequipment protectedby SPD at sub-distribution

8 Electronic Systems Protection | Design & technical solut ions

SPD connections should be kept as short as possible, ideally below 0.25 m between SPD, live conductors & earth, but in any case not more than 0.5 m, to reduce risk of additive inductive voltage drops across the conductors.

Figure 6: Total lead length for SPDs installed in parallel

Fusing and Installation of SPDsTransient overvoltage protection to BS 7671

Critical length of connecting conductorsAn installed SPD will always present a higher voltage to equipment compared with the voltage protection level stated on a manufacturer’s data sheet, due to additive inductive voltage drops across the conductors on the SPD’s connecting leads.

Therefore, for maximum transient overvoltage protection the connecting conductors must be kept as short as possible.

BS 7671 Clause 534.2.9 defines that for SPDs installed in parallel (shunt), the total lead length between line conductors, protective conductor and SPD preferably should not exceed 0.5m and never exceed 1m. Current loops should be avoided.

For SPDs installed in-line (series), the lead length between the protective conductor and SPD preferably should not exceed 0.5 m and never exceed 1m.

Best practicePoor installation can significantly reduce effectiveness of SPDs. Therefore, keeping connecting leads as short as possible is vital to maximize performance, and minimize additive inductive voltages.

Best practice cabling techniques, such as binding together connecting leads over as much of their length as possible, using cable ties or spiral wrap, is highly effective in cancellinginductance.

The combination of an SPD with low voltage protection level (Up), and short, tightly bound connecting leads will lead to an optimum controlled installation meeting the requirements of BS 7671.

Page 58: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

58 Line Protection Equipment 0115 ABB Low Voltage

Cross-sectional area of connecting conductorsFollowing BS 7671, the cross-sectional area of the SPD’s connecting conductors shall be:- Not less than 4 mm2 copper (or equivalent) if the crosssectional area of the line conductors is greater than or equal to 4 mm2, or

- Not less than that of the line conductors, where the line conductors have a cross-sectional area less than 4 mm2

- For Type 1 SPDs, a minimum of 16 mm2 copper or equivalent, where a structural LPS is installed

These cross-sectional area values are based on the surge current that these SPD connecting leads need to handle, not the supply current. However, in the event of a short circuit, for example due to the end of life condition of the SPD, the connecting leads to the SPD would need to be protected by a suitable Overcurrent Protective Device (OCPD).

BS 7671 defines requirements to ensure that fault protection shall remain effective in the protected installation even in the case of failure of SPDs.Therefore an SPD needs to be protected against short circuits through the use

of an appropriate OCPD capable of eliminating the short-circuit. In effect, the SPD should have a dedicated OCPD installed in-line on its connecting leads,ensuring that this OCPD to the SPD discriminates with the upstream OCPD of the main supply.

Selection of the appropriate OCPD in-line with the SPD must ensure sufficient discrimination with the upstream OCPD of the main supply load. Installers should refer to OCPD manufacturers’ operating characteristics to ensurediscrimination, particularly where an installation includes a mixture of types of OCPD.

However, as a general rule of thumb, the OCPD for the SPD should be rated at approximately half the value of the upstream supply OCPD.

ABB surge solutionsFurse Electronic Systems ProtectionFurse Part No ABB Order Code ABB MCB Part No ABB Fuse Part No

ESP 415/I/TNS 7TCA085460R0101 58035 - 125 E 933N/125 - 125 A

ESP 415/III/TNS 7TCA085460R0103 58035 - 125 E 933N/125 - 125 A

ESP 415 M4 7TCA085460R0124 58035 - 125 E 933N/125 - 125 A

ESP 415 M2 7TCA085460R0119 58035 - 125 E 933N/125 - 125 A

ESP 415 M1 7TCA085460R0112 S203P – 50 50 NA E 933N/50 - 50 A

ESP 415 D1 7TCA085460R0105 S203P – 50 50 NA E 933N/50 - 50 A

OVR T1+2 3N 15-255-7 2CTB815101R9000 58035 - 125 E 933N/125 - 125 A

OVR T2 3N 40 275s P TS 2CTB803395R0200 S203P - 50 NA E 933N/50 - 50 A

OVR Plus N3 40 2CTB803701R0300 N/A N/A

OVR Plus N1 20 2CTB803701R0700 N/A N/A

*Maximum MCB/fuse ratings must be in accordance with the installation to follow coordination rules with main or upstream short circuit protection.

Electronic Systems Protection | Design & technical solut ions 9

Cross-sectional area of connecting conductors Following BS 7671, the cross-sectional area of the SPD’sconnecting conductors shall be: – Not less than 4 mm2 copper (or equivalent) if the cross-

sectional area of the line conductors is greater than or equal to 4 mm2, or

– Not less than that of the line conductors, where the line conductors have a cross-sectional area less than 4 mm2

– For Type 1 SPDs, a minimum of 16 mm2 copper or equivalent, where a structural LPS is installed

These cross-sectional area values are based on thesurge current that these SPD connecting leads need tohandle, not the supply current.

However, in the event of a short circuit, for exampledue to the end of life condition of the SPD, the connecting leads to the SPD would need to be protected by a suitable Overcurrent Protective Device (OCPD).

BS 7671 defines requirements to ensure that fault protection shall remain effective in the protected installation even in the case of failure of SPDs.

Therefore an SPD needs to be protected against short circuits through the use of an appropriate OCPD capable of eliminating the short-circuit. In effect, the SPD should have a dedicated OCPD installed in-line on its connecting leads, ensuring that this OCPD to the SPD discriminates with the upstream OCPD of the main supply.

Selection of the appropriate OCPD in-line with the SPD must ensure sufficient discrimination with the upstream OCPD of the main supply load. Installers should refer to OCPD manufacturers’ operating characteristics to ensure discrimination, particularly where an installation includes a mixture of types of OCPD.

However, as a general rule of thumb, the OCPD for the SPD should be rated at approximately half the value of the upstream supply OCPD.

Furse Part No ABB Order Code ABB MCB Part No* ABB Fuse Part No*

ESP 415/I/TNS 7TCA085460R0101 58035 - 125 E 933N/125 - 125 A

ESP 415/III/TNS 7TCA085460R0103 58035 - 125 E 933N/125 - 125 A

ESP 415 M4 7TCA085460R0124 58035 - 125 E 933N/125 - 125 A

ESP 415 M2 7TCA085460R0119 58035 - 125 E 933N/125 - 125 A

ESP 415 M1 7TCA085460R0112 S203P – 50 NA E 933N/50 - 50 A

ESP 415 D1 7TCA085460R0105 S203P – 50 NA E 933N/50 - 50 A

ABB Part No ABB Order Code ABB MCB Part No* ABB Fuse Part No*

OVR T1+2 3N 15-255-7 2CTB815101R9000 58035 - 125 E 933N/125 - 125 A

OVR T2 3N 40 275s P TS 2CTB803395R0200 S203P - 50 NA E 933N/50 - 50 A

OVR Plus N3 40 2CTB803701R0300 N/A N/A

OVR Plus N1 20 2CTB803701R0700 N/A N/A

ABB surge solutionsFurse Electronic Systems Protection

Other products to consider

ESP SL Series ESP TN/JP SeriesESP Cat 6 Series

For protection of twisted pair signalling applications

For protection of local area networks up to Cat 6 including Power over Ethernet (PoE)

For protection of equipment connected to BT telephone (BS 6312) socket

*Maximum MCB/fuse ratings must be in accordance with the installation to follow coordination rules with main or upstream short circuit protection.

Electronic Systems Protection | Design & technical solut ions 9

Cross-sectional area of connecting conductors Following BS 7671, the cross-sectional area of the SPD’sconnecting conductors shall be: – Not less than 4 mm2 copper (or equivalent) if the cross-

sectional area of the line conductors is greater than or equal to 4 mm2, or

– Not less than that of the line conductors, where the line conductors have a cross-sectional area less than 4 mm2

– For Type 1 SPDs, a minimum of 16 mm2 copper or equivalent, where a structural LPS is installed

These cross-sectional area values are based on thesurge current that these SPD connecting leads need tohandle, not the supply current.

However, in the event of a short circuit, for exampledue to the end of life condition of the SPD, the connecting leads to the SPD would need to be protected by a suitable Overcurrent Protective Device (OCPD).

BS 7671 defines requirements to ensure that fault protection shall remain effective in the protected installation even in the case of failure of SPDs.

Therefore an SPD needs to be protected against short circuits through the use of an appropriate OCPD capable of eliminating the short-circuit. In effect, the SPD should have a dedicated OCPD installed in-line on its connecting leads, ensuring that this OCPD to the SPD discriminates with the upstream OCPD of the main supply.

Selection of the appropriate OCPD in-line with the SPD must ensure sufficient discrimination with the upstream OCPD of the main supply load. Installers should refer to OCPD manufacturers’ operating characteristics to ensure discrimination, particularly where an installation includes a mixture of types of OCPD.

However, as a general rule of thumb, the OCPD for the SPD should be rated at approximately half the value of the upstream supply OCPD.

Furse Part No ABB Order Code ABB MCB Part No* ABB Fuse Part No*

ESP 415/I/TNS 7TCA085460R0101 58035 - 125 E 933N/125 - 125 A

ESP 415/III/TNS 7TCA085460R0103 58035 - 125 E 933N/125 - 125 A

ESP 415 M4 7TCA085460R0124 58035 - 125 E 933N/125 - 125 A

ESP 415 M2 7TCA085460R0119 58035 - 125 E 933N/125 - 125 A

ESP 415 M1 7TCA085460R0112 S203P – 50 NA E 933N/50 - 50 A

ESP 415 D1 7TCA085460R0105 S203P – 50 NA E 933N/50 - 50 A

ABB Part No ABB Order Code ABB MCB Part No* ABB Fuse Part No*

OVR T1+2 3N 15-255-7 2CTB815101R9000 58035 - 125 E 933N/125 - 125 A

OVR T2 3N 40 275s P TS 2CTB803395R0200 S203P - 50 NA E 933N/50 - 50 A

OVR Plus N3 40 2CTB803701R0300 N/A N/A

OVR Plus N1 20 2CTB803701R0700 N/A N/A

ABB surge solutionsFurse Electronic Systems Protection

Other products to consider

ESP SL Series ESP TN/JP SeriesESP Cat 6 Series

For protection of twisted pair signalling applications

For protection of local area networks up to Cat 6 including Power over Ethernet (PoE)

For protection of equipment connected to BT telephone (BS 6312) socket

*Maximum MCB/fuse ratings must be in accordance with the installation to follow coordination rules with main or upstream short circuit protection.

Electronic Systems Protection | Design & technical solut ions 9

Cross-sectional area of connecting conductors Following BS 7671, the cross-sectional area of the SPD’sconnecting conductors shall be: – Not less than 4 mm2 copper (or equivalent) if the cross-

sectional area of the line conductors is greater than or equal to 4 mm2, or

– Not less than that of the line conductors, where the line conductors have a cross-sectional area less than 4 mm2

– For Type 1 SPDs, a minimum of 16 mm2 copper or equivalent, where a structural LPS is installed

These cross-sectional area values are based on thesurge current that these SPD connecting leads need tohandle, not the supply current.

However, in the event of a short circuit, for exampledue to the end of life condition of the SPD, the connecting leads to the SPD would need to be protected by a suitable Overcurrent Protective Device (OCPD).

BS 7671 defines requirements to ensure that fault protection shall remain effective in the protected installation even in the case of failure of SPDs.

Therefore an SPD needs to be protected against short circuits through the use of an appropriate OCPD capable of eliminating the short-circuit. In effect, the SPD should have a dedicated OCPD installed in-line on its connecting leads, ensuring that this OCPD to the SPD discriminates with the upstream OCPD of the main supply.

Selection of the appropriate OCPD in-line with the SPD must ensure sufficient discrimination with the upstream OCPD of the main supply load. Installers should refer to OCPD manufacturers’ operating characteristics to ensure discrimination, particularly where an installation includes a mixture of types of OCPD.

However, as a general rule of thumb, the OCPD for the SPD should be rated at approximately half the value of the upstream supply OCPD.

Furse Part No ABB Order Code ABB MCB Part No* ABB Fuse Part No*

ESP 415/I/TNS 7TCA085460R0101 58035 - 125 E 933N/125 - 125 A

ESP 415/III/TNS 7TCA085460R0103 58035 - 125 E 933N/125 - 125 A

ESP 415 M4 7TCA085460R0124 58035 - 125 E 933N/125 - 125 A

ESP 415 M2 7TCA085460R0119 58035 - 125 E 933N/125 - 125 A

ESP 415 M1 7TCA085460R0112 S203P – 50 NA E 933N/50 - 50 A

ESP 415 D1 7TCA085460R0105 S203P – 50 NA E 933N/50 - 50 A

ABB Part No ABB Order Code ABB MCB Part No* ABB Fuse Part No*

OVR T1+2 3N 15-255-7 2CTB815101R9000 58035 - 125 E 933N/125 - 125 A

OVR T2 3N 40 275s P TS 2CTB803395R0200 S203P - 50 NA E 933N/50 - 50 A

OVR Plus N3 40 2CTB803701R0300 N/A N/A

OVR Plus N1 20 2CTB803701R0700 N/A N/A

ABB surge solutionsFurse Electronic Systems Protection

Other products to consider

ESP SL Series ESP TN/JP SeriesESP Cat 6 Series

For protection of twisted pair signalling applications

For protection of local area networks up to Cat 6 including Power over Ethernet (PoE)

For protection of equipment connected to BT telephone (BS 6312) socket

*Maximum MCB/fuse ratings must be in accordance with the installation to follow coordination rules with main or upstream short circuit protection.

ESP SL Series For protection of twistedpair signalling applications

ESP Cat 6 Series For protection of local area networks up to Cat 6 including Power over Ethernet (PoE)

ESP TN/JP Series For protection of equipment connected to BT telephone (BS 6312) socket

Other products to consider

Page 59: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

58 Line Protection Equipment 0115 ABB Low Voltage

Page 60: Short form catalogue Modular Din rail components MCBs ... · Modular Din rail components MCBs, RCDs, meters & surge protection Short form catalogue

© C

opyr

ight

ABB

Ltd

9AK

K106

354A

1400

Contact us

ABB LtdTower CourtFoleshill Enterprise ParkCourtaulds WayCoventry CV6 5NX

Tel: 0333 999 9900Fax: 0333 999 9901

Email: [email protected] Twitter: @ABBUKLVP

www.abb.co.uk/lowvoltage

Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Ltd does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosureto third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB Ltd.

Copyright © 2015 ABB LtdAll rights reserved

Power and productivityfor a better worldTM


Recommended