+ All Categories
Home > Documents > Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Date post: 26-Mar-2015
Category:
Upload: taylor-hollis
View: 225 times
Download: 0 times
Share this document with a friend
Popular Tags:
100
Siemens Energy & Automation Chapter 6 NEMA Products Training Session
Transcript
Page 1: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Chapter 6 NEMA Products Training

Session

Page 2: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

SMF Fractional HP Manual Motor Starter

Page 6/3 to 6/4

Page 3: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

SMF Fractional Motor Starters

• Class SMF Fractional HP Starters are provided with Melting Alloy Overloads, and the used on AC single-phase motors up to 1 HP.

• Manual Starters are used when the motor is in sight of the controller (Guideline @ 50ft.)

• Applications: Fans, conveyors, pumps and small machine tools.

Page 4: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Fractional Horsepower Manual Starters

• Product Class SMF:– Open Type– NEMA Type 1B General Purpose

Flush Mounting (No Enclosure Provided)

– NEMA Type 1 General Purpose Enclosure, Surface Mounting.

– NEMA Type 3R, 4, & 12

Page 5: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

SMF Fractional Horsepower Manual Motor Starters

Page 6: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

MMS & MRS Fractional HP

Switches Page 6/5 to 6/6

Page 7: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

MMS & MRS Manual Switches

• Class MMS & MRS Fractional HP Switches provide ON-OFF control where overload protection is not required.

• These switches are rated for use on 3-phase motors up to 10 HP @ 460V.

• Manual Switches are used when the motor is in sight of the controller (Guideline @ 50ft.)

• Applications: Fans, conveyors, pumps and small machine tools.

Page 8: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Fractional Manual Switches

• Product Class MMS & MRS:– Open Type– NEMA Type 1B General Purpose

Flush Mounting (No Enclosure Provided)

– NEMA Type 1 General Purpose Enclosure, Surface Mounting.

– NEMA Type 3R, 4, & 12

Page 9: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

MMS & MRS Fractional Horsepower Switches

Page 10: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Class 11 Manual Motor Starter

Page 11: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

• Product Class 11 Family:– Open Type 3RV– NEMA Type 1 – NEMA Type 7 & 9

• Class I Flammable gasses may ignite Group C & D list of chemicals

• Class II Combustible dust Group E, F & G list of metals, carbons, grain

– NEMA Type 3 & 4, NEMA Type 7 & 9

Page 12: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

Page 13: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

Page 14: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

Page 15: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

• Across the line provide local control only.

• 1Ø, 2Ø or 3Ø up to 15HP @ 460 V

• Ambient compensation Bimetal prevents nuisance tripping

• Built-in Phase loss trip, protects Motors

• Can be used for Type E application (self-protected Combo Starter). Saves Money!

Page 16: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

• LVP low voltage protection optional. Reduces Potential injuries. Meets OSHA

• ON/OFF handle lock out with visible trip indicator.

Prevents unauthorized entry

• Short Circuit trip at 13 times FLA for rated current.

• Test trip function.

• UL listed CSA Certified, and CE

Page 17: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Product Nomenclature

11AD3B

Class

SizeFLA1,2,..

Model 3RV

Power Poles

Enclosure Type

Page 18: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

• Applications include:GrindersPower SawsConveyorsFansPumpsBlowersMachinery

Page 19: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

• Field Modifications

LVP mounted on the right

Shunt trip mounted on the right

Front Plug-in or side mounted Auxiliary Contacts

Pilot lights for NEMA 1 only

Red, Green or Amber, 24-600V

Page 20: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starters & Switches

Q & A

Page 21: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Manual Starter

Page 22: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Open Contactors & Starters

Page 23: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Overload Relays

• What is the Difference:

Between A Short Circuit & An Overload ?

Page 24: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Overload Relays

• What Is A Short Circuit?

– An Extreme Amount Of Current Usually Caused By A Fault To Another Phase Or To Ground.

– Fault Currents Can Exceed Several Thousand Amps For A Very Short Period Of Time Which Can Cause Very Extensive Equipment Damage. Fault Currents May Even Reach Up To 200,000 Amps On Some Systems.

Page 25: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Overload Relays

• What Is An Overload?

– 1. An Operating Condition Where The Load Current Exceeds Normal Operation.

– 2. A Motor That Is Overloaded May Draw 6 Times Its Normal Operating Current (Full Load Current).

– 3. An Overload For Even Several Minutes May Cause Severe Motor Damage.

Page 26: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Overload Relays

• What Are The Differences Between …

• A Fuse Or A Circuit Breaker And An Overload Relay?

Page 27: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Overload Relays

• Short Circuit Protection Devices– Fuses - One Time Use Only – Magnetic Circuit Breakers - Reusable After

Reset

• Overload Protection Devices– Time Delay Fuses -One Time Use Only – Overload Relays - Able To Reset

– Thermal Magnetic Circuit Breakers - Also Able To Reset

ghaweg
Page 28: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Overload Relays

• How Overload Relays Work• Monitors Over-current Condition On Motor

Power Leads—Indirectly Thermal Type Overload Relay—Directly Magnetic or Electronic Type Overload

Relay

• Turns Off Control Circuit During Overload Condition—OL Relay NO Contact Turns Off Motor Starter

Coil Circuit

Page 29: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Overload Relays

Page 30: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Bimetal Overload

Page 31: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Bimetal Temp Comp. OLR

Page 32: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Electronic OLR

Page 33: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Electronic OLR

Page 34: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

OLR Class 10, 20, 30

Page 35: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Motor Starter Circuit

Page 36: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Non-Combination and Combination Starters

Page 37: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersProduct Lines

Non-Combination Starters

Class 14 (full voltage non-reversing)

Class 22 (full voltage reversing)

Class 30 (full voltage two-speed)

Combination Starters

Class 17 (full voltage non-reversing with disconnect)

Class 18 (full voltage non-reversing with circuit breaker)

Class 25 (full voltage reversing with disconnect)

Class 26 (full voltage reversing with circuit breaker)

Class 32 (full voltage two-speed with either DISC or CB) Contactors

Class 40 (full voltage non-reversing) Class 43 (full voltage reversing)

Page 38: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Class 14 Non-Combination Starters on Pages 10 – 14.

Page 39: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersNon-Combination Starter Products

Class 14 Non-Combination Starter

Page 40: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersNon-Combination Starter - Features and Benefits

Heavy Duty Industrial Construction Enclosure Types:

NEMA 1 Lift-Off Type “Clamshell” (Manufactured with TOX process)

NEMA 1, 4x, 7&9, 12 (field convertible to 3/3R) Hinged

Standard Width and Extra Wide Enclosures Removable Door/Cover Siemens offers ten NEMA Size Starters from

Size 00 up to Size 8 rated 900HP 600V. Siemens also offers three Heavy Duty Half-Size

Starters in 1 ¾, 2 ½ & 3 ½ for Cost and Space Savings.

Overloads - ESP100 and Bimetal Ambient Compensated

Pilot Device Mounting Holes in enclosures

Page 41: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersNon-Combination Starter - Features and Benefits

Factory & Field Modifications Pages 6/71 to 6/87. Control Power Transformer (CPT) Pilot Devices Control Relays Control Fuses Auxiliary Contacts Meters (Hinged Enclosures Only) Terminal Blocks Etc…

Page 42: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters Non-Combination Starter Nomenclature

1 4 B S A 3 2 B A

Class

Coil

Size

Model

Current Range (ESP only)

Power Pole / Enclosure Size

Enclosure Type

X X

Suffix

Page 43: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersNEC Requirement for Combination Starter

NEC 430 requires that Motors have:

Disconnect

Short Circuit Protective Device

Controller

Overload Protection

Page 44: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Class 17 & 18 Combination Starters on Pages 15 – 24.

Page 45: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters Combination Starter Products

Class 17 Combination Starter

Page 46: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters Combination Starter Products

Class 17 Combination Starter Class 18 Combination Starter

Page 47: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters Combination Starter Products

Class 25 Combination Starter Class 26 Combination Starter

Page 48: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters Combination Starter Products

Class 32 Combination Starter

Page 49: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters Combination Starter Products

Combination Starters

Fiberglass enclosure Explosion proof enclosure

Page 50: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersCombination Starter - Features and Benefits

Heavy Duty Industrial Construction Manufactured with TOX process on Most

Enclosures Standard Width and Extra Wide Enclosures Four Enclosure Types: NEMA 1, 4x, 7&9, 12

(field convertible to 3/3R and 4) Removable Door Disconnect Types are Field Convertible to

Fusible Disconnects 100KA Amp Fault Protection with Class R

Fuses to 600V or MCP (Mag Only) to 480V Panel Pre-Drilled for 230V or 600V Fuses

Page 51: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersCombination Starter - Features and Benefits

Up to 900HP 600V - NEMA Size 8 with ESP100 Solid State Overload Relay

Half Size Starters for Cost and Space Savings Overloads - ESP100 and Bimetal Ambient

Compensated White Mounting Panel Pre-Drilled for CPT,

Relays, Primary Fuse Kit, Pilot Device Mounting Holes in enclosures

Page 52: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersCombination Starter - Features and Benefits

Factory & Field Modifications Control Power Transformer (CPT) Pilot Devices Control Relays Control Fuses Auxiliary Contacts Meters Terminal Blocks Etc…

Page 53: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters Combination Starter Nomenclature

1 7 C S D 9 2 N F

Class

Coil

Size

Model

Current Range (ESP only)

Enclosure Size

Enclosure Type

X X

Suffix

F

CB Hp Code (for CB w/ bimetal OLR only)

Page 54: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersApplications

Pumps Fans Material Handling & Conveyor Systems Machine Tools HVAC Equipment Compressors Construction Projects Used in Commercial and Industrial facilities

Page 55: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersOptions/Modifications - Definitions

Page 6/83 to 6/87 covers Factory Modifications that are added to the product, per sales order, at the Siemens factory or distribution Center.

Page 6/71 to 6/81covers Field Modifications that are added to the product by distributor/customer with standard catalog field mod kits. This applies to both pre and post installation of base product.

Page 56: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersField Modification Kits

Page 57: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA StartersField Modification Kits

Page 58: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Enclosed NEMA Starters

Q & A

Page 59: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Half Sizes

Page 60: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

NEMA Sizes

Page 61: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

NEMA Starter Family up to size 4

Page 62: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Open NEMA Starter

Page 63: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Open Starter Features

Snap On”Auxiliary

Easy CoilRemoval

ESP 100 Overload

ThermalOverload Relay Available

New Solid State Starter Kits are AvailableSizes 00-4 in this designNEMA Rugged Design, Quality ProductsSize 5 & 6 are Sirius

Page 64: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 Electronic OLR

• True phase loss protection

• Overload trips within 3 seconds on phase loss, even on lightly loaded motors (60% of minimum dial setting)

• Customer Benefit: Saves Motors!!!

• Thermal overloads just can’t provide this degree of protection

Page 65: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Electronic OLR

• Heaterless Construction– No heaters to install, stock, or maintain

• Customer Benefit: – Heaters require time and labor to install

Page 66: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP

• Self - Powered– Generates its own low voltage control power

through the same sensors that read motor current

• Customer Benefit: – Separate 120VAC control power is not

required

Page 67: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• Ambient Insensitive– Overload not affected by temperature, rated -

30 °C to 70 °C

• Customer Benefit: – No nuisance tripping on hot days. No open

panel doors with fans blowing on controls.

Page 68: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• 99% of heat generated by thermal overload removed

• Customer Benefit: – Other electronic equipment in panel runs

cooler, energy savings. More equipment could go into panel due to lower heat rise.

Page 69: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• Energy Savings– Thermal overloads generate 9 to 24 watts per

relay– Based on 10 watts per overload and $0.10

per kW/hr, ESP100 will save $7.88 per year in energy costs

• This can really be significant if user has hundreds of starters!!!

Page 70: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 ORL

• Self protected from short circuits– Upon the event of a short circuit, the current

transformers saturate before any damage is done to the overload

• Customer Benefit: – No need to replace overload relay or heater

elements after a short circuit as is required with thermal overloads

Page 71: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• ± 2 % repeat accuracy

• Customer Benefit: – Under the same conditions, trip time on the

overload will be the same within ± 2%

Page 72: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• Circuit boards have conformal coating on them.

• Customer Benefit: – Rugged design that will hold up in humid,

corrosive environments

Page 73: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• No two labels are the same – Every ESP100 overload is individually

calibrated and a custom label is printed for that overload.

• Customer Benefit: – Superior accuracy of dial setting - no

competitor does this!

Page 74: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• Thermal Memory – “Remembers” the heat buildup in hot or

overloaded motors

• Customer Benefit: – Trips faster on a restart since the motor

windings are hot

Page 75: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• Simple Installation – Mount it, wire it, dial in FLA

• Customer Benefit – Fewer connections, saves installation time

Page 76: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

• Retrofit Capabilities– Direct Replacement for:

• Cutler Hammer Citation Line and Freedom Series• GE 300 Line• Square D Type S

– An additional “piggy-back” plate is available to retrofit the following:

• Allen Bradley Bulletin 509 and Bulletin 709• Westinghouse Series A200

Page 77: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

ESP100 OLR

Page 78: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Starters with ESP100 Family

Page 79: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Auxiliary Contact.

•Snap - on Mounting

•Bifurcated Contacts

•No Tools Required

•Up to 8 Contacts – Max. 4 NC

Page 80: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Applications

• Machine tools

• Material Handling

• Compressors

• Hoists

• Automotives

• Industrial Equipment

Page 81: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Starters Kits (for use with ESP100 only)

Page 82: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Starters Kits – Customer Benefits

• Reduced lead-time – From Days to Minutes• Reduce Inventory – Instead of stocking scores of

different starters, simply stock a few starter kits, ESP100 kits and coil kits. With these basic “building blocks” you virtually have hundreds of products on-hand.

• Quality – Same high quality you are accustomed to with our products found in these new starter kits.

• UL Listed - By correctly following the instructions included with the kits, the product you build is UL Listed.

• Standard 110-120/220-240VAC dual voltage coil - Standard dual voltage coil, easily swapped with different voltage coil if required.

• Available in Non-Reversing sizes 00-4 and reversing sizes 0-2

Page 83: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Product Lines

• Class 14 Non-Reversing starters– From fractional HP up to 900 HP (NEMA size 00 – 8

including half-sizes)– Operating voltages up to 575 V– Overloads - ESP100 and Bimetal Ambient Compensated

• Class 22 Reversing starters– From fractional HP up to 900 HP (NEMA size 00 – 8

including half-sizes)– Operating voltages up to 575 V– Overloads - ESP100 and Bimetal Ambient Compensated

Page 84: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Product Lines

• Class 30 Two Speed– One and Two Windings– Constant or Variable Torque– Constant Horsepower– From fractional HP up to 100 HP (NEMA size 0 – 4 including

half-sizes)– Operating voltages up to 575 V– Overloads - ESP100 and Bimetal Ambient Compensated

• Class 40 (Non-Reversing) & 43 (Reversing) Contactors– From fractional HP up to 900 HP (NEMA size 00 – 8

including half-sizes)– Operating voltages up to 575 V– Vacuum contactors NEMA sizes 4,5 & 6 (Non-Reversing

only)

Page 85: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Nomenclature

14 Starter C 0 S 1990 S.S. O/L, THREE PHASE 1 2 Power poles 2 3 wire (No aux. A OpenD 1 Sz. 0-3½ A 0.25-1 (1994) 1 phase included) B NEMA 1E 1¾ & 1P Sz. 4½ - 6 B 0.75-3 (1994) 3 3 Power poles 3 3 Wire w/ D NEMA 3F 2 T 1992 Size 4 C 3-6 3 phase Start-Stop PB E NEMA 4G 2½ R 1997 Self reset D 5-10 (1991) 4 4 Power poles 4 2 Wire w/HOA paintedH 3 version 2.5-10 (1994) 3 phase sel. switch F NEMA 4XI 3½ (Sizes 0-5 only) E 9-18 w/aux power pole 5 2 Wire H NEMA 7 & 9J 4 P 2002 (size 5 & 6) F 13-27 5 5 Power poles 9 2 Wire w/ boltedK 4½ G 20-40 3 phase stop button** K NEMA 9L 5 H 22-45 w/aux power poles A Auto-OFF L NEMA 7 & 9M 6 J 30-60 sel. switch threaded

K 45-90 B ON-OFF O NEMA 12L 57-115 sel. switch R NEMA 1B3M 67-135 C Full-part W NEMA 4 SSS 100-210 sel. switchU 100-270 (Size 5 T Model) D Start-stopU 55-270 (Size 5 P Model) sel. switchX 200-540 E Auto-manual sw.

SINGLE PHASEA 0.25-1 (1994) REVISIONS:B 0.75-3 (1994) B. Added "Suffix" col CN52392 2/17/97D 2.5-10 (1994) C. Add ref. note for suffixE 5-16 (1994) CN58817 DA 4/19/01

D. Size K was R, L was K CN59108 DA 6/12/01E. Add "P" (sz 5&6) CN61351 GF 12/3/03__

** Not available on open style. * Jumper "A" is not included with the coil. _+ Refers to transformer primary voltage on Size 6.. _

2PILOT CONTROL CIRC.MODEL

S14CLASS

ACURRENT RANGE

CSIZE

AENCLOSURE

3POWER POLES

Page 86: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

FLA 3Ø AC Motors

Page 87: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Select Heater

• Select Heater for the following BiMetal Overload Relays Class 10 & 20. From the table in the catalog

• 14CP32A*81 SZ0, FLA 4.8, 460V

• 14GP32A*81 SZ2½, FLA 54, 230V

• 14DP12A*81 SZ1, FLA 20, 115V

• 3ø, 10HP, 460V, 60Hz, 3Pole

• 1ø, 2HP, 115V, 60Hz, 2Pole

Page 88: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Heater Elements

• Catalog # CL10 CL20

• 14CP32A*81 K36 E46

• 14GP32A*81 K77 E78

• 14DP12A*81 K60 E61

• 14DP32A*81 K56 E57

• 14DP12A*81 K62 E65

Page 89: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting and Heating Contactors Pages 60 - 65

Page 90: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting ContactorProduct Lines

Non-Combination

Class LEN (20 – 400A)

Class CLM (20 – 400A)

Combination

Class LE (20 – 300A)

Class CM (20 – 300A)

Page 91: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Non-Combination

CLM style Lighting Contactor LEN style Lighting Contactor

Page 92: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Combination

Lighting Combination

Page 93: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Features and Benefits

Compact Design Enclosure Types:

NEMA 1 Lift-Off Type “Clamshell” (Manufactured with TOX process)

NEMA 1, 4x, 12 (field convertible to 3/3R) Hinged

Standard Width and Extra Wide Enclosures Removable Door/Cover Up to 400Amps (20 – 60 available up to 12

poles, 100 – 400Amps 3 poles) Available in Combination form with choice

of: Fusible Disconnect Non-Fusible Disconnect Circuit Breaker

Pilot Device Mounting Holes in enclosures

Page 94: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Non-Combination Starter - Features and Benefits

Factory & Field Modifications Control Power Transformer (CPT) Pilot Devices Control Relays Control Fuses Auxiliary Contacts Terminal Blocks Control Modules Etc…

Page 95: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Electrically Held Nomenclature

LEN00B003120A

ClassDisconnect TypeFuse Clip or Circuit Breaker RatingEnclosure TypeAmp RatingNumber Open PolesNumber Closed PoleCoil VoltageSeries

Page 96: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Mechanically & Magnetically Held Nomenclature

CLM0B03120

ClassEnclosure Type/RatingAmp RatingNumber PolesCoil Voltage

Page 97: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Field Modification Kits

Page 98: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting Contactor Field Modification Kits

Power Pole 20A CLM (CLM4097334)

Control Modules 20A CLM (CLM4379771)

Power Pole 20A LEN (49LN20A)

Auxiliary Contact 30 - 400A CLM (CLMHCAK11)

Page 99: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

Lighting and Heating Contactors

Q & A

Page 100: Siemens Energy & Automation Chapter 6 NEMA Products Training Session.

Siemens Energy & Automation

(CPTs)


Recommended