+ All Categories
Home > Documents > Siemens LU 5221

Siemens LU 5221

Date post: 04-Jun-2018
Category:
Upload: ehincapiem
View: 223 times
Download: 0 times
Share this document with a friend

of 10

Transcript
  • 8/14/2019 Siemens LU 5221

    1/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    The New Probe LU & LR

  • 8/14/2019 Siemens LU 5221

    2/10

    Siemens Milltronics Process Instruments

    SITRANS Probe LU

    SITRANS Probe LRNew and extremely experienced

  • 8/14/2019 Siemens LU 5221

    3/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    Your Application Decides the Technology

    Analyse the applicationMaterial, temperature,

    pressure, range, atmosphere

    Recommend preferredtechnology

    LU or LR

    Determine correct modelProcess connection,approval

    Overview

    Appl icat ion Success

    Features & Benefits

    Product Definition

    Principle ofOperation

    Product Verification

    Appl icat ions

    System Integration

  • 8/14/2019 Siemens LU 5221

    4/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    SITRANS Probe LU When and Why?

    Ideal in simple storage vessels:Overview

    Appl icat ion Success

    Features & Benefits

    Product Definition

    Principle ofOperation

    Product Verification

    Appl icat ions

    System Integration

    AcidsWater/wastewater

    FoodOils

    Juices

  • 8/14/2019 Siemens LU 5221

    5/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    SITRANS Probe LR When and Why?

    Microwaves are virtually unaffectedby atmospheres with:

    ExtremeTemperatures

    PressureExtremes

    or Vacuum

    Dust

    Vapor Volatiles

    Overview

    Appl icat ion Success

    Features & Benefits

    Product Definition

    Principle ofOperation

    Product Verification

    Appl icat ions

    System Integration

    Si ill i l

  • 8/14/2019 Siemens LU 5221

    6/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    SITRANS Probe Application Matrix

    Preferred Acceptable Not recommended

    ? LU or LR normally OK for wet / dense foamFor dry / light foams, performance is not predictable

    Application Requirement LU LR

    Range 0.25 m to 3 m

    Range 0.3 m to 12 m

    Range to 20 m

    Narrow shot with obstructions

    Steel still ing well

    Accuracy 0.15% 0.1%

    Temperature gradients in airspace?

    Pressure Ambient V AC- 3 bar

    Vapors present (solvent, hydrocarbons)

    Foam present ? ?

    CO 2 Gas present

    Overview

    Appl icat ion Success

    Features & Benefits

    Product Definition

    Principle ofOperation

    Product Verification

    Appl icat ions

    System Integration

    Si Millt i PI 5 L l

  • 8/14/2019 Siemens LU 5221

    7/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    Specifications at a Glance

    Specification Probe LU Ultrasonic Probe LRRadar

    6m (20ft) or 12m * (40ft)

    0.15% *

    3mm

    24Vdc nom. 30Vdc max.

    N/A

    < 5 sec.

    Process Temperature: -40C to 85C * -40C to 80C

    -40C to 80C *

    At mosp here

    2 NPT, G, or BSP

    ETFE or PVDF

    Plastic - PBT with PEI lid

    Type 4x, Nema 4x,Nema 6, IP67, IP68 (2 m) *

    ATEX 1 G [ia], CSA/FM Class I,Div. 1 [ia]With sui table barrier

    N/A

    Range 20m (65ft)

    Accuracy: 0.1%

    Repeatability: 5mm

    Power: 24Vdc nom. 30Vdc max.

    Dielectric Constant: > 1.6 (< 3.0 use stilling well)

    Update time: 1 sec.

    Am bient Temperature: -40C to 80C

    Pressure: Vacuum to 3 bar

    Sensor Process Connection: 1-1/2 NPT, G, or BSP

    Polypropylene

    Enclosure: Plastic - PBT with PEI lid

    Safety Approvals: ATEX 1 G [ia], CSA/FM Class I, Div. 1 [ia]With sui table barrier

    Radio Approvals: Industry Canada, FCC, R&TTE

    Ingress Protection: Type 4x, Nema 4x,Nema 6, IP67, IP68

    The Probe Legacy

    SITRANS ProbeIntroduction

    Features & Benefi ts

    General Theory

    Applicat ionSelection

    System Integration

    Product Verification

    Competition

    Sales Tools

    Siemens Milltronics PI 5 Level

  • 8/14/2019 Siemens LU 5221

    8/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    Mounting Details

    LR LU

    FillStream

    The Probe Legacy

    SITRANS ProbeIntroduction

    Features & Benefi ts

    General Theory

    Applicat ionSelection

    System Integration

    Product Verification

    Competition

    Sales Tools

    Siemens Milltronics PI 5 Level

  • 8/14/2019 Siemens LU 5221

    9/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    SITRANS LR Probe Loop load specification

    For example:If supply voltage is 24VDC, then maximum loopresistance allowable is 550 ohms.

    Typical loads are:Remote displaysBarrier HART resistor PLC inputetc.

    Overview

    Theory

    SITRANS LR Family

    Product definitionand Specs

    Features & Benefi ts

    System Integration

    Antenna Select ion

    Applicat ionConsiderations

    Competition

    Sales Tools

    Siemens Milltronics PI 5 Level

  • 8/14/2019 Siemens LU 5221

    10/10

    Bereichskennungoder Produktname

    Siemens Milltronics PI 5 Level

    Intrinsically Safe Installations

    Probe LR shownIdentical for Probe LU

    The Probe Legacy

    SITRANS ProbeIntroduction

    Features & Benefi ts

    General Theory

    Applicat ionSelection

    System Integration

    Product Verification

    Competition

    Sales Tools


Recommended