Siemens Industry Oil and Gas ConferenceMarch 30th, 2016
John SullivanDecreased Cost, Increased Performance of a LACT Skid using the S7-1200
Agenda
Introduction
Parts of LACT Skid
Case Study Presentation Hardware Overview Communication Challenges
Questions
Presenter InfoJohn SullivanProject Director
• Siemens Certified Professional• Control Systems PE
• B.S. in Mechanical Engineering – Rose Hulman Institute of Technology
• With DMC since 2009• Relocated to Denver in August of 2014 with 3
other engineers.
DMC Company Profile
Industries Served:
AutomotiveChemical and Food ProcessingElectronics/SemiconductorHydraulicsLaboratory Testing
Machine Tool Material HandlingMetal ConvertingPackagingPharmaceuticalPrinting & Textiles Oil & Gas
Established in 1996, offices in Chicago, Boston, Denver, Houston, New York & customers
throughout the worldemployees &
growing
85+
Areas of Expertise
MANUFACTURINGAUTOMATION & INTELLIGENCE
PLC Programming
Motion Control Engineering &Servo Systems
HMI & SCADA Expertise
Intelligent Data& Web BasedSystems
Vision Inspection Expertise
Robotics
TEST & MEASUREMENT AUTOMATION
NI FPGA
LabVIEW Development
Test Stand Design
Machine Vision
Data Analysis & Reporting
NI Real-Time
CUSTOM SOFTWARE& HARDWARE DEVELOPMENT
PC Application Development
Product Development
Web Application, iOS, Android & App Development
Embedded Design & Programming
SDK, API & Driver Development
Database Systems
MICROSOFT CONSULTING SERVICES
10 10
5
5
INDIVIDUAL CERTIFICATIONS
Manufacturing & Automation Certifications
DMC has the highest number of S7 certified engineers in the US.
LACT Skid Introduction
What is a LACT Unit?Lease Automatic Custody Transfer Unit
What is a LACT Unit
Image from FMC Technologies
What Is Important?
DMC Core Values
1. Accuracy (Flow Meter)
Accuracy(Flow
Meter)
1. Need flow measurements to be very accurate
2. Variety of Flow Meters based on conditions
3. Different Flow Meters have different interfaces to Controls
Key Features
2. Remote Connectivity
Remote Connectivi
ty
1. Data is always collected by central station
2. Data connection is not always reliable
3. Need multiple interfaces to provide for different customer standards
DMC Core Values
3. Cost
Cost
1. Transfers money, but can’t cost much of it
2. Competition drives down cost
3. Lowest Cost usually makes the decision
Key Features
4. Controls
Controls
1. Reliability!
2. Need items that are quick and easy to configure
3. Need items with a range of communication options
4. Remote connectivity is hugely desired
Case Study
Project Requirements Configurable for Multiple Flow Meters
Variety of Communication Options
Local Control for Operator
Remote Monitoring
Availability for Expansion for Remote Connectivity
Low Hardware Costs
Customer ownership for future changes
Motivation for Change Current Solution
AB MicroLogix PLC Panel View Component HMI Different Versions of Code for
Different Flow Meters
Solution S7-1200 Comfort Panel Common Code Base for a
Variety of Flow Meters. Single PLC for variety of
different customer connections.
Which PLC?
The S7-1200 Communication/Remote
Connection Profinet, Modbus TCP, Ethernet,
Ethernet/IP on board Expansion for Modbus RTU,
Profibus, AS-Interface, and others
Cost Lower cost than most
competitor products Onboard IO helped drop overall
cost Common Code Base
Able to develop code to meet a
variety of different meters and sensors.
The S7-1200 Web Server
Web Server with data tables to provide remote troubleshooting
SMTP Option to add in emails
based on events PLC Data Logging
Built in Logging Functionality on the PLC (accessible via webserver)
Not implemented, but an option for growth.
Which HMI?
Comfort Panel Configurable Analog Scaling
Pop-up to change scaling of analog inputs.
Back-up Local Data Needed local data logging in
case connection went down. Wanted to trend non
financial values as well. Password Protection & User
Admin Needed custom password
protection for different screens
Results
1. Far more functionality for a lower cost
2. Less work for OEM when building different skids
3. Better looking HMI
4. Lots of room for expansion to future features
Recap
1. LACT Units are vital for business1. Good Flow Meter2. Smart Controls3. Good Communication
2. Siemens Solution1. S7-1200 is low cost high
feature processor2. Improved capability and
room for expansion
Questions?