Updated 10 July 2015
Signata Memory Interface DDR3 Analysis Suite Datasheet
For More Information: Please contact Signata Corporation, 2260 East Bidwell Street #1102, Folsom, CA. 95630, USA
Phone: 1.844.SIGNATA (1.844.744.6282) – Email: [email protected] – Website: www.signatacorp.com. Copyright © Signata Corporation. All rights reserved. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. Signata is registered trademarks of Signata Corporation. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
www.signatacorp.com Page | 1
Summary of Key Features:
Reads wfm, csv, txt, and simulation tr0 waveform files
Easy correlation between simulation and lab scope waveforms
Supports up to 12 channels with multiple sample rates and size
Performs multiple measurements from the same set of waveforms
Supports “compliance” parameters and “user defined” parameters
Analysis mode supported are interactive, batch, and stream
Events trace-back to waveforms
Supports automation and analysis report generation
The one tool for: electrical verification, debug, compliance, correlation, specification development
Quick Finder quickly locates and open controls and data
Easily share analysis with geographically dispersed teams
Refer to Signata Waveform Viewer datasheet for further information on the main window viewer features
Free 15-day trial Download the Signata DDR3 Analysis Suite software and use it free for 15 days. Load your scope waveforms to quickly evaluate the application using previously captured signals.
www.signatacorp.com
The Signata DDR3 Analysis Suite software allows you to view and analyze DDR3 (JESD79-3F) and LPDDR3 (JESD209-3B) data captured from your
oscilloscope anytime and anywhere. You will gain instant insight into device performance, spec compliance, quickly determine the root cause of any
electrical issues and substantially increase your team’s performance.
Updated 10 July 2015
Signata Memory Interface DDR3 Analysis Suite Datasheet
For More Information: Please contact Signata Corporation, 2260 East Bidwell Street #1102, Folsom, CA. 95630, USA
Phone: 1.844.SIGNATA (1.844.744.6282) – Email: [email protected] – Website: www.signatacorp.com. Copyright © Signata Corporation. All rights reserved. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. Signata is registered trademarks of Signata Corporation. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
www.signatacorp.com Page | 2
Key Features: File, Utilities, Help
File You can easily create, open, close, save, save as, and view recent projects from here for your analysis during offline use or in the lab on the scope. You can also perform the usual tasks such as print, preview, and page setup.
Utilities From here, for your convenience, you can either quickly save an image or the waveform on the Viewer. For the Results Viewer, if you choose to open an existing project under the File menu, you easily view the measurement results, including the Data Eye, in an open window that displays everything in an easy to read format. The Automation Server allows you to establish connection with oscilloscope as part of the automation process using Signata APIs.
Help The ‘Viewer Quick Guide’ is a visual tool which shows you a Signata Waveform Viewer snapshot with feature definitions, at a quick glance. The user license can easily be renewed by submitting a request to the designated Signata representative (About Signata Analysis Suite).
Updated 10 July 2015
Signata Memory Interface DDR3 Analysis Suite Datasheet
For More Information: Please contact Signata Corporation, 2260 East Bidwell Street #1102, Folsom, CA. 95630, USA
Phone: 1.844.SIGNATA (1.844.744.6282) – Email: [email protected] – Website: www.signatacorp.com. Copyright © Signata Corporation. All rights reserved. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. Signata is registered trademarks of Signata Corporation. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
www.signatacorp.com Page | 3
Key Feature: DDR3/LPDDR3 Analysis
Analysis This is where you select which analysis module to use. When either DDR3 or LPDDR3 analysis module is selected the respected analysis panel will pop-up.
DDR3/LPDDR3 Analysis Panel You can easily load waveforms, select measurements, select /define parameters to be used (either compliance or user defined). The analysis types supported are either interactive, batch, or stream. When run is completed the results are displayed in the data grid on the panel. You can also quickly view the Current Runset results, the accumulated count Runset results, or the Eye Diagram. In addition, you can select any of the various measurements to see the actual measurement displayed on the signal in the Waveform Viewer window. And as you continue to select different measurement events, they are reflected back in the Viewer window, thus making it easier to follow the signal and to debug issues.
Updated 10 July 2015
Signata Memory Interface DDR3 Analysis Suite Datasheet
For More Information: Please contact Signata Corporation, 2260 East Bidwell Street #1102, Folsom, CA. 95630, USA
Phone: 1.844.SIGNATA (1.844.744.6282) – Email: [email protected] – Website: www.signatacorp.com. Copyright © Signata Corporation. All rights reserved. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. Signata is registered trademarks of Signata Corporation. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
www.signatacorp.com Page | 4
Note: TBD* = availability depends on customer request Main Waveform Viewer Window Please refer to the Signata Waveform Viewer Datasheet for information regarding the main Waveform Viewer window.
Applications:
DDR3/LPDDR3 interface electrical verification
DDR3/LPDDR3 interface electrical characterization
Debug issues
Correlation between measurement and simulation
Compliance
Specification development
Supported LPDDR3 measurements
Item Measurements Availability
1. DQ/DQS WR Diff (dq, dqs, cs, clk) Now
2. CS Now
3. CKE Now
4. CA Now
5. Clock Now
6. DQ/DQS WR Diff (dq, dqs, clk) Now
7. DQ/DQS RD Diff (dq, dqs, clk) Now
8. TX only - phase TBD*
9. DQS cross-over TBD*
10. Clock Single-ended TBD*
Supported DDR3 measurements
Item Measurements Availability
1. DQ/DQS WR Diff (dq, dqs, cs, clk) Now
2. CTRL Now
3. CA Now
4. Clock Now
5. DQ/DQS RD Diff (dq, dqs, clk) Now
6. DQ/DQS WR Diff (dq, dqs, clk) TBD*
7. TX only - phase TBD*
8. DQS cross-over TBD*
9. Clock Single-ended TBD*
Updated 10 July 2015
Signata Memory Interface DDR3 Analysis Suite Datasheet
For More Information: Please contact Signata Corporation, 2260 East Bidwell Street #1102, Folsom, CA. 95630, USA
Phone: 1.844.SIGNATA (1.844.744.6282) – Email: [email protected] – Website: www.signatacorp.com. Copyright © Signata Corporation. All rights reserved. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. Signata is registered trademarks of Signata Corporation. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
www.signatacorp.com Page | 5
Supported File Formats and Software License
Supported File Formats .wfm, .csv, .txt, .tr0
Licensing model Nodelock
Signata DDR3 Analysis Suite Software Ordering Information
Product Code Description
SD3-1000B-001S DDR3 & LPDDR3 analyzer
SD3-1000B-001D DDR3 analyzer only
SD3-1000B-001L LPDDR3 analyzer only
System Requirements
Minimum Optimum
Operating Systems Windows 7 64bit, Windows 8.x 64bit
Windows 7 64bit, Windows 8.x 64bit
System Memory 4GB 8GB or Higher
Display Resolution 1024 x 768 1920 x 1080 or Higher
Hard Drive Space 10GB Sufficient space, as required, to manage many large waveform files