    High Voltage

    Technical Services

    www.silcar.com.au

    High voltage testing

    Commissioning and maintenance of transmission

    Generation

    Distribution

    Mining and process plant electrical equipment switchboards

    Transformers

    Generators

    Motors and associated electrical apparatus

  • 8/22/2019 SIL 1168 HV Tech Brochure

    2/8

    02

    Silcar high voltage technical services utilises highly

    skilled and trained technical staff to provide a wide

    range of testing, commissioning and high voltagetest services Australia wide.

    Silcar provide a wide range of testing, commissioning and high voltage test services

  • 8/22/2019 SIL 1168 HV Tech Brochure

    3/8

    Testing and commissioning services for

    transmission, distribution, generation and

    mining industries electrical infrastructure

    Silcar provides commissioning and maintenance testing of protection relays

    and schemes. We utilise highly skilled eld technical personnel using Doble and

    Omicron secondary injection test equipment to provide:

    3 Project management and commissioning of protection and control schemes

    in new and existing sub stations

    3 Factory Acceptance Testing of electrical switchboards (FAT)

    3 Site Acceptance Testing of electrical ewitchboards (SAT)

    3 Maintenance of existing protection schemes

    3 Development of data setting les for numerical protection relays

    3 Test plans, relay setting and relay logic les

    3 Simulation testing of SCADA systems to ensure correct functions integrity

    3 Development of quality Inspection Test Plans (ITPs).

    Testing Capability

    3 Protection relay programming and scheme testing

    3 Protection relay maintenance

    3 Secondary injection

    3 Primary injection

    3 Current transformer testing

    3 Voltage transformer testing

    3 Battery discharge testing

    3 High voltage testing of switchboard apparatus

    3 Ductor testing

    3 Insulation resistance testing

    3 Circuit breaker testing and commissioning

    3 Metering equipment commissioning and testing

    3 Scada interface testing

    3 On Load measurement of current and voltage

    3 Fault nding

    3 Earth resistance testing

    Silcar protection scheme testingand commissioning services

  • 8/22/2019 SIL 1168 HV Tech Brochure

    4/8

    Dielectric Loss Angle test (DLA)

    The DLA test, also known as DDF, Doble, Power factor test, is used

    to determine conditions of an insulation medium in a high voltage

    apparatus.

    Applications: transformers, current & voltage transformers,

    bushings, generators, motors

    and surge arrestors.

    Silcar provides a specialist diagnostic high voltage testing capability.

    Technical Services staff utilise specialised condition monitoring

    and diagnostic equipment to quickly and accurately establish the

    condition of HV plant. The range of available services and their

    typical application is outlined below:

    Frequency

    Response

    Analysis (FRA)

    The FRA test system is designed to detect winding movements

    resulting from shipping damage, or subjection to low impedance

    through faults.

    Applications: power transformers.

    Partial Discharge test (PD)

    Partial Discharge is an electrical discharge that occurs across

    a portion of the insulation between two conducting electrodes,

    without completely bridging the gap. Partial discharges can occur

    in voids in solid insulation (paper, polymer), gas bubbles in liquid

    insulation or around an electrode in a gas (corona).

    PD testing is particularly important where HV plant has a high

    criticality. This may be due to its age, historical failures or the

    consequences of its failure (such as position in the network).

    Applications: transformers, current and voltage transformers,

    bushings, generators, motors, switchgear (SF6).

    Frequency response analysis (FRA)

    2MHz range amplitude

    Frequency (hz 000s)

    a2 - n RMS b2 - n RMS

    5

    0

    -5

    -10

    -15

    -20

    -25

    -30

    0 200 400 600 800 1000 1200 1400 1600 1800 2000

    Gain(db)

    c2 - n RMS

    Very Low Frequency (VLF)

    high potential test

    The VLF test focuses on high voltage cables, but can also be applied

    to rotating machinery, transformers, arrestors and insulators.TheVLF high potential test is the only high potential test approved for

    XLPE cables.

    Silcar high voltage testing services

    04 Silcar provide a wide range of testing, commissioning and high voltage test services

  • 8/22/2019 SIL 1168 HV Tech Brochure

    5/8

    Ring Flux test

    The ring ux test can detect deep core lamination breakdown as well

    as back core burning, which may not be detected by the ELCID test.

    The core damage is represented by a localised heating of the core

    laminations, which is then detected by thermography equipment.

    Applications: generator stators

    Recurrent Surge Oscillograph

    (RSO) test

    This test is most sensitive to inter-turn insulation faults, or shorted

    turns on generator rotors. It can also be used to detect open circuits

    and earth faults of the rotor windings.

    Applications: generator and motor rotors

    Thermography (detection tool)

    Thermography will quickly locate hot spots and determine the

    severity of the problem. Thermography is also particularly useful forinspecting indoor and outdoor components such as motor control

    centres, substations, breaker panels, switchgear, transformers and

    circuit breakers.

    Applications: transformers, current and voltage transformers,

    bushings, generators, motors, switchgear

    DC Insulation Resistance (IR)

    and Polarization Index (PI)

    A megohmmeter (insulation resistance tester), is used to measure

    the ohmic value of an insulator under a direct voltage of great

    stability. The insulation resistance test is a non-destructive test and

    can detect where insulation is satisfactory.

    Applications: transformers, current and voltage transformers,

    bushings, generators, motors, switchgear.

    Transformer Ratio test

    Transformer turns ratio measurements are best made with

    specialised instruments that include detailed connection and

    operating instructions. The measured turns ratio should be within

    0.5% of the calculated turns ratio. Ratios outside this limit may be

    the result of winding damage, which has shorted or opened some

    winding turns.

    Applications: transformers, current and voltage transformers

    Winding Resistance test

    Transformers are subject to vibration. Problems or faults occur

    due to poor design, assembly, handing, poor environments,

    overloading or poor maintenance. Measuring the resistance of the

    windings assures the connections are correct and the resistance

    measurements indicate there are no severe mismatches or opens.

    Applications: transformers, current and voltage transformers,

    bushings, generators, motors, switchgear (SF6).

    Electromagnetic Core Imperfection

    Detection (ELCID) test

    The ELCID test was developed in the late 1970s by the Central

    Electricity Generating Board (CEGB) in the UK to enable it to readily

    test machines where a high power source for traditional ring ux test

    was not available. Because of a large number of laminations and thin

    insulation layers there is a high probability of insulation breakdown.

    The fault currents induced can be large and cause excessive local

    core heating. If not detected and repaired at an early stage, faults

    can be catastrophic.

    Applications: generators, motors

    Pole A

    Pole B

    Flux Probe

    Quadrature

    Axis

    Slot

    Leakage

    Flux

    Air Gap (Rotor) Flux test

    Flux monitoring via permanently mounted air gap ux probes is a

    proven technology in synchronous machines to determine if turn-to-

    turn shorts have occurred in the rotor winding. Flux measurements

    are the most powerful means of monitoring the condition of rotor

    windings on-line and can provide information on the integrity of

    the rotor winding inter-turn insulation. This information is critical

    in planning maintenance, explaining abnormal vibrations, and

    verifying new and rewound rotor integrity.

    Applications: generator rotors

  • 8/22/2019 SIL 1168 HV Tech Brochure

    6/8

    06

    2012 UGL SP Ausnet Ringwood, Glenrowan and West

    Melbourne Terminal Stations Victoria.

    Testing and commissioning associated with 66kV CT replacement

    program.

    2012 UGL Verve Power Station WA.

    Commissioning engineers to provide assistance with commissioning

    of generator and transformer protection schemes.

    2011 2012 Siemens Goonyella Terminal Substation Moranbah

    Queensland.

    120 KV terminal substation (green eld) pre-commission and

    commission substation.

    2012 2013 Siemens Woodside KGP Karratha, WA.

    Pre-commissioning and commissioning of the substation 33kV GIS

    replacement program.

    2011 2012 Siemens Eraring Power Station.

    Test & commissioning on generator/transformer protection upgrade.

    2011 2012 Siemens Sino Iron Power Plant Cape Preston, WA.

    Pre-commissioning and commissioning work at Sino Iron port substation.

    2010 2011 Archer Zone Substation Darwin Darwin, NT.

    66Kv to 11 KV zone substation (green eld) pre-commission and

    commission substation.

    2010 2011 Mortlake Power Station 500kV Switchyard

    Mortlake, Victoria.

    500kV switchgear and protection scheme commissioning.

    2009 2010 Sino Iron Power Plant Cape Preston, WA.

    220kV, 33kV, 11kV & 6.6kV switchgear and protection commissioning.

    2008 TRUenergy Yallourn Power Station.

    Generator stator re-wind. High voltage testing of stator winding duringthe outage. ELCID test before, during and after re-wind.

    2007 Rowville Terminal Station.

    333.3MVA 500/220kV single phase auto transformers congured as

    YNa0d1. Full commissioning and testing.

    2007 - Kalgoolie Nickel Smelter.

    B Set furnace transformer change over full turn key operation.

    Including all SAT and witness FAT, Alstom, Rocklea, Queensland.

    2007 2009 Jeeralang Power Station Protection Upgrade

    Jeeralang, Victoria.

    7 x generator/transformer protection scheme commissioning.

    2006 - 2007 Transend Package B Substation Project TAS.

    4 x 110kV/22kV Substations switchgear, transformer and protection

    commissioning

    Major projects include

    Silcar has been providing high voltage services since 2000. Projects include substation commissioning, maintenance of

    transmission, distribution and process plant electrical infrastructure, and high voltage testing of transformers, generators,

    motors and switchboards and associated apparatus.

    Our activities include Factory Acceptance Testing and Site Acceptance Testing on site pre-commissioning, commissioning

    and maintenance.

    Major Silcar projects

    Silcar provide a wide range of testing, commissioning and high voltage test services

  • 8/22/2019 SIL 1168 HV Tech Brochure

    7/8

    TRANSFORMERS

    3 Frequency Response Analysis (FRA)

    3 Dielectric Loss Angle (DLA) test on bushings and transformers

    3 Insulation resistance test & polarisation index test

    3 Winding resistance test

    3 Winding ratio test

    3 Impedance test

    3 Applied voltage or AC high potential (Hi-pot) test

    3 Induced voltage test

    3 Surge arrestor watts loss test

    3 Condition monitoring reports

    3 Visual inspections

    GENERATORS AND MOTORS

    3 Dielectric Loss Angle (DLA) test

    3 Partial Discharge test (PD)

    3 Electromagnetic Core Imperfection Detection (ELCID) test

    3 Winding resistance test

    3 Impedance test

    3 Recurrent Surge Oscillograph (RSO) test

    3 Current spectrum analysis

    3 Applied voltage or AC high potential (Hi-pot) test

    3 Iron core loss test

    3 Broken rotor bars (Induction Heater) test

    3 Insulation resistance test

    3 Polarisation index test

    3 Air gap probe ux test

    3 DC controlled over voltage test (step & continuous) also known

    as step ramp test

    3 Visual inspections

    OTHER TESTS

    3 Cable high potential (DC or VLF [very low frequency]) test

    3 Instrumentation (functionality test and calibration)

    3 Protection and metering testing

    3 Primary injection

    3 Energy measurement

    3 Testing of operating equipment

    3 Battery discharge testing

    POWER TRANSFORMERS

    3 Sweep Frequency Response Analysis (SFRA)

    3 Dielectric Response Analysis (DIRANA)

    3 Winding Dielectric Loss Angle (DLA)

    3 HV Bushing DLA

    3 Winding Insulation Resistance (IR)

    3 Polarisation Index (PI)

    3 Winding Resistance (through taps- HV)

    3 Low voltage impedance

    3 Low voltage induce

    3 Low voltage no-load loss & load loss

    3 Separate source

    3 Single phase excitation (through taps)

    3 Surge arrestors IR & DLA

    3 Winding & oil temperature indicator calibration/check

    3 Auxiliary controls

    3 Visual inspection

    3 Condition monitoring report

    ROTATING MACHINES

    Stator Core:

    3 Inspection services

    3 Core lamination tightness

    3Thermography

    3 Electromagnetic Core Imperfection Detector (ELCID)

    3 Ring Flux (c/w Thermography)

    Stator Winding

    3 Insulation Resistance (IR)

    3 Polarisation Index (PI)

    3 Winding Dielectric Loss Angle (DLA) - power frequency up 25kV AC

    3 Off - Line Partial Discharge (PD) - power frequency up to 25kV AC

    3 DC resistance

    3 DC Controlled Overvoltage (DCCO)

    3 AC & DC Hi - Pot

    Rotor Winding3 Recurrent Surge Oscillograph (RSO)

    3 Off-line at stand still / speed

    3 Air Gap Flux Probe - on line

    3 Current Spectrum Analysis - on line

    3 Residual magnetisms

    3 Insulation Resistance (IR)

    3 Polarisation

    3 Resistance

    3 Impedance

    3 AC high potential

    3 Pole balance

    HIGH VOLTAGE CABLES3 Insulation resistance

    3 AC high potential (Power Frequency & VLF)

    3 DC high potential

    3 Dielectric Loss Angle (DLA)

    Silcar provides the following tests:

    Silcar Services

  • 8/22/2019 SIL 1168 HV Tech Brochure

    8/8

    colemanstudios.c

    om.a

    u

    National Office Victoria

    25 37 Huntingdale Road

    Burwood, Victoria, Australia 3125

    P (03) 9273 7600 F (03) 9017 1424

    Email [email protected]

    WA Perth Regional Office

    Unit B, 2-10 Kewdale Road

    Welshpool WA 6106

    Telephone (08) 9351 7300

    QLD Brisbane Office

    Unit 1, 237 Fison Avenue West

    Eagle Farm QLD 4099

    Telephone (07) 3291 2433

    High Voltage Technical Services Head Of fice

    43 Saviges Road, Moe, Victoria, 3825

    (PO Box 549)

    P (03) 5122 4000

    F (03) 9017 1444

    www.silcar.com.au colemanstudios.com.au

    Ownership

    Silcars 50/50 shareholders are Siemens Ltd (a global leader in electricalengineering and electronics) and Thiess Pty Ltd (a leading integrated engineering

    and services provider in Australasia and South East Asia).

    Silcar Corporate Locations & Operations

    With over 1,800 employees Australia-wide, Silcar services technically

    complex assets using a nationally distributed support network to

    ensure 24/7 maintenance support. Whether you require capital city

    CBD site coverage, or cover for the remotest outback location, Silcar

    can deliver your requirements.

    Darwin

    Cairns

    Brisbane

    Sydney

    Hobart

    Adelaide

    Perth

    Melbourne

    Rockhampton

    Silcar State Offices

    Silcar Service Coverage

    Canberra

    New Caledonia


Recommended