  • 7/28/2019 SIMATIC for industrial HVAC

    1/8

    Increased economic efficiency

    for industrial building automation

    simaticFOR INDUSTRIAL HVAC

    Heating, Ventilation

    & Air Conditioning

  • 7/28/2019 SIMATIC for industrial HVAC

    2/8

    SIMATIC for industrial HVAC

    SIMATIC,

    the trademark for efficient automation solutions in manu-

    facturing and process control, is also the right choice as far

    as solutions for industrial building automation systems areconcerned.

    HVAC solutions based on SIMATIC provide the

    following advantages:

    Totally Integrated Automation

    When implementing optimized automation solutions in

    industrial applications, one of the most important tasks is

    to implement all plant areas as well as all auxiliary systemsuniformly with one single technology.

    HVAC (Heating, Ventilation & Air Conditioning) is one of the

    most important auxiliary systems, decisive for production

    as well as for a consistently high product quality.

    Both the horizontal and vertical integration of the automation

    solution into production and the auxiliary systems ensure

    optimum availability, a high degree of effectiveness and the

    economic efficiency of the entire plant.

    2

  • 7/28/2019 SIMATIC for industrial HVAC

    3/8

    Cost reduction

    SIMATIC S7 is the leading industrial automation system in

    the market. It covers almost all tasks in manufacturing and

    process automation.

    With HVAC solutions that are based on SIMATIC, the user

    benefits from the uniformity of the industry standard. As

    a result, you have the following advantages:

    Use of one single automation system for processing/

    production and auxiliary systems

    Cost reduction thanks to the standardization of

    components on the automation level

    Industry-standard HVAC automation quality

    Easy operator control and monitoring

    Reduced number of interfaces

    Simplification of maintenance and servicing

    Integration

    The integration of automation from production to building

    technology increases efficiency, reliability and economic

    efficiency of the entire plant. SIMATIC HVAC is an open, fast,precise and extremely reliable system specifically designed

    for industrial requirements. Thus it offers a maximum of

    integration and flexibility in addition to operating safety.

    All from a single source integration of field devices

    HVAC has many different proprietary field devices. Field

    devices are, for example, valves, damper actuators, pumps

    as well as special designs and versions of sensors and

    actuators. Siemens Building Technology offers a wide

    range of these products. Thanks to the cooperation of

    the A&D and SBT Divisions, the customer now receivesall components required for an HVAC solution based on

    SIMATIC from a single source.

    3

  • 7/28/2019 SIMATIC for industrial HVAC

    4/8

    SIMATIC Easy Select

    Until now, HVAC requirements could only be met by using

    larger SIMATIC S7 controllers.

    New is the library

    HVAC Lite Library

    for small standalone applications in heating, ventilation

    and air-conditioning systems for a particularly low-cost

    implementation, since this library has been designed for

    the cost-effective mini PLCs and compact controls of the

    S7-300 and ET 200S CPU device family. This library

    can therefore be used for the automation of hall ventilation

    and ventilation systems, or even small air conditioning

    systems without separate visualization and with no or

    just a slight degree of networking.

    The HVAC Lite Library is the main component of the new

    SIMATIC HVAC Easy Select configuration solution for the

    optimized processing of simple HVAC applications. Pres-

    ently, six configuration solutions have been defined:

    4

  • 7/28/2019 SIMATIC for industrial HVAC

    5/8

    The configuration solutions show the optimum compo-

    nent selection for the respective application, for the

    controller and appropriate I/O as well as for a range of

    applicable field devices from which the required actuators

    and sensors have to be selected. To round it off, the

    HVAC Lite Library is an add-on library to STEP 7 for HVAC

    applications and enables the solution provider to develop

    a corresponding system solution with minimum overhead.

    The supplied variant of the library contains sample projects

    for all seven Easy Select tasks, which then only need to be

    configured according to the data contained in the project.

    The HVAC Lite Library has very little memory requirements,

    so that small S7 controllers can be used for the respective

    solutions. Thus, the user is now also able to serve the

    industrial HVAC sector that demands such small, cost-

    effective standalone HVAC applications. The number of

    SIMATIC HVAC Easy Select variants is principally not fixed.

    Depending on the requirements on correspondingly pre-

    configured solutions, further configuration solutions can

    be created.

    5

    HVAC Easy Select 1 Outside air or exhaust air ventilation systems

    without air treatment

    HVAC Easy Select 2 Ventilation system, heating or cooling with one

    heating/cooling coil and one fan

    HVAC Easy Select 3 Ventilation system, heating or cooling with one

    register and with two fansHVAC Easy Select 4 Ventilation system with mixing chamber,

    heating and cooling

    HVAC Easy Select 5 Ventilation system with plate heat recovery,

    heating and cooling, two-speed fan

    HVAC Easy Select 6 Complete ventilation system with heat recovery and

    air washer as primary system for air volume control

  • 7/28/2019 SIMATIC for industrial HVAC

    6/8

    6

    SIMATIC Easy Select:Application examplesThese four application examples describe how you can use the

    SIMATIC HVAC Easy Select packages for your heating, air condi-

    tioning and ventilation tasks.

    SIMATIC HVAC Easy Select packages are configuration solutions that

    show how you can configure a specific HVAC application quickly

    and easily. They consist of different hardware components from

    SIMATIC controllers to I/O units right up to a selection of correspond-

    ing field devices.

    The heart of the SIMATIC HVAC Easy Select package is the add-on

    HVAC Lite Library for STEP 7, which you can use to configure the

    required application quickly and conveniently. And to make it even

    easier for you, we have included a sample application that matches

    the particular task specification to be covered by the package.

    All you have to do is set the relevant parameters.

    Mixed air ventilation system,heating, cascade control

    Application/savings

    You want to configure a heating system as a

    mixed air ventilation system with cascade con-

    trol? Thats no problem if you are using the right

    SIMATIC HVAC Easy Select package!

    The advantage of the room supply air or extract

    air cascade control is the considerably enhanced

    control performance compared to a regular room

    temperature control. Thus you can achieve an

    enhancement of the control quality by a factor

    of 5 to 8 and accelerate the control compared

    to when using a room temperature sensor.

    Furthermore, the use of recirculated air saves

    heating energy.

    The cascade control makes it possible to limit

    the maximum supply air temperature, which

    cannot be done with a regular room temperature

    control.

    The HVAC Lite Library also includes STEP 7 sample

    applications for configuring the described HVAC

    task. The SIMATIC HVAC Easy Select configuration

    solution thus helps you to reach your goal faster.

  • 7/28/2019 SIMATIC for industrial HVAC

    7/8

    7

    Outside air ventilation system,heating/cooling, cascade control

    Application/savings

    This last HVAC sample application, which is cov-

    ered by the SIMATIC HVAC Easy Select package 4,

    has all the advantages of the previously described

    applications plus the possibility of cooling with

    extract air.

    Limitation of the maximum and minimum

    supply air temperature is possible here as well,

    as described in the previous examples. By

    raising the room temperature setpoint in the

    summer time in accordance with DIN 1946,

    cooling energy is saved.

    The cooling coil is hydraulically driven with con-

    stant cold water flow since no precipitation of

    humidity is required. This enables considerable

    energy savings compared to volume-controlled

    cooling coil operation.

    As in the three previous HVAC tasks, a sample

    configuration is included in the scope of supply

    of the HVAC Lite Library for the SIMATIC HVAC

    Easy Select package 4. The sample configuration

    only needs to be adapted to the specific

    requirements of the individual application.

    Application/savings

    The application of the outside air ventilation

    system with heating option described by SIMATIC

    HVAC Easy Select 3 has the savings benefits of

    the two Easy Select configuration solutions de-

    scribed above based on the outside air ventilation

    principle.

    Outside air ventilation system,

    heating, cascade control

    Application/savings

    In addition to the functionality described with

    the first SIMATIC HVAC Easy Select package, the

    minimum and maximum supply air temperature

    can be limited. A regular room temperature

    control system cannot do this.

    The HVAC task implemented in the second

    SIMATIC HVAC Easy Select package also includes

    the use of recirculated air. If adhering to the

    minimum outside air rate, a great amount of

    energy can be saved. In particular, when cooling

    with high outside temperatures, savings can be

    very significant if you switch over to a minimum

    proportion of outside air. An additional energy

    savings potential is the possibility to increase the

    room temperature setpoint in the summer time

    according to DIN 1946.

    Considerable energy savings can be achieved

    with an application described in the SIMATIC

    HVAC Easy Select package by measuring the

    extract air temperature. A relevant sample

    application is supplied with the HVAC Lite Library.

    Mixed air ventilation system,heating/cooling, cascade control

  • 7/28/2019 SIMATIC for industrial HVAC

    8/8

    w w w . s i e m e n s . d e / i n d u s t r i a l - h v a c

    Please send further information on the followingtopics:

    First name, surname

    Company

    Department

    Street

    City/ZIP

    Phone/Fax

    E-mail

    Fax +49 911 / 978 - 3321Info service AD/Z1069

    Mr./Ms.

    www.siemens.com/industrial-hvac

    Siemens AG

    Automation and Drives

    SIMATIC Industrial HVAC

    P.O. Box 48 48, 90327 Nuremberg

    Germany

    Siemens Building Technologies

    Friesstrasse 20

    60388 Frankfurt, Germany

    The information provided in this brochure contains merely gen-

    eral descriptions or characteristics of performance which in case

    of actual use do not always apply as described or which may

    change as a result of fur ther development of the products. An

    obligation to provide the respective characteristics shall only

    exist if expressly agreed in the terms of contract.

    SIMATIC HVAC Easy Select application examples

    SIMATIC HVAC Automation

    HVAC field devices

    Catalogs

    SIMATIC

    Field devices

    SIMATIC is a Siemens trademark. Other brands usedin this brochure may be trademarks whose use bythird parties for their own purposes might infringethe rights of their owners.


Recommended