Date post: | 13-Sep-2015 |
Category: |
Documents |
Upload: | pratapkomaravolu |
View: | 490 times |
Download: | 16 times |
Unrestricted / Siemens AG 2014. All Rights Reserved. siemens.com/answers
PCS 7 Historian and ReportingSIMATIC PCS 7
Unrestricted / Siemens AG 2014. All Rights Reserved.
Process Historian and Information ServerPosition within SIMATIC PCS 7
Unrestricted / Siemens AG 2014. All Rights Reserved.
Process Historian
No additional engineering for this standard product: out of the box High performance: Faster call up of historical data High data availability through redundant PH Server Supports plant extension without interrupting the production process Longer data storage on the server using the new compression algorithim on OS server side
Full integrated in PCS 7 Scalable and centralized storage of process data in real time Support for Multiple PCS 7 projects including Batch Data Support for PCS 7 Single Stations Open System: support for ODBC, OLE DB and ADO.NET Support for 3rd party Reporting System (Microsoft Reporting Service) Redundant PH Server
Customer Benefit
Project 2
Project 1Process Historian
Tags, Alarms, Batches
Archiving
OS ServerTags, Alarme
PCS 7 Project "A" PCS 7 Project "B"
OS EinzelstationTags, Alarme
BATCH ServerBatch Daten
PCS 7 Project "C" Process Historian
Unrestricted / Siemens AG 2014. All Rights Reserved.
Process Historian Console Dashboard
Improved Visibility to the Setup, Performance and Maintenance of the Historian I/O Systems System Diagnosis with Event
Log Back up and Restore Compression Licensing Used and Available Tags Stored Alarms Free Space Recovery
Unrestricted / Siemens AG 2014. All Rights Reserved.
Process HistorianEngineering
11
22
33
Unrestricted / Siemens AG 2014. All Rights Reserved.
SIMATIC Process Historian (PH) 2014
Database Recovery Management Backup of the entire PH database in one file Full restore of the database backup in a new PH database
Migration of CAS database (support for PCS 7 V7.0 and V7.1) Automatic data compression in different steps Time: minute, hour, day Aggregation functions: number of values, SUM, MIN, MAX, integral value
Read Access to the PH-Archive via PH OPC UA Server Store and Forward functionality Buffering of all tag and alarm data in a database file on the OS system in
case of connection loss to PH Data transmission from the Store and Forward buffer to PH after connection recovery
Higher data availability through system related backup and full-restore functionality for the entire database
Increased performance during read access to PH archive with automatic data compression
Added Value
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information ServerReporting
Easy access to historical plant data anywhere Induvidual creation of report and storage Data security through user administration Easy creation and administration of customer reports, automatic forward of reports via mail Production optimization remotely and in real time
New reporting system based on Microsoft Reporting Services Web Front-End-Report based on internet Information Service Information Server Client based on Internet Explorer Data access within Microsoft Office applications (Word, Excel) Data source for creation of reports
Process Historian Server Operatior Station
Reporting
Web Browser Microsoft Office(Excel, Word)
Office PC
Basiert aufMicrosoft SQL ServerReporting Services
Information Server
Customer Benefit
Unrestricted / Siemens AG 2014. All Rights Reserved.
SIMATIC Information Server
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information ServerReport with Standard Templates (RDL)
Tables for messagesand process values
Trends andgraphicalelements
Statistics of alarmsystem
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information ServerTemplate creation with Report Editors => Report Builder
Shift / Daily / Monthly Production Report for Production: actual vs. plan Yield Material consumption: actual vs. plan Energy consumption: gas, steam, cooling liquid etc.
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information Server Integrated Reporting with MS Office
Office add-in for Excel and Word MS Office 2003, 2007 and 2010 supported
Reading tags Reading alarms Using report templates
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information Server Creating a Report with Excel
1. Start Excel
3. Insert tags
4. Configure tag
2. Log on to server
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information ServerReport with Excel Tag Configuration
5. Creating an Excel report
6. Result
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information Server Report using Report Templates in MS Excel
1. Create report
2. Select alarms
3. Result
Unrestricted / Siemens AG 2014. All Rights Reserved.
SIMATIC Information Server (IS) 2014
Completely redesigned layout and improved look-and-feel Implementation of filter and lists to manage large numbers of
created reports Extension of the IS performance spectrum through new export
formats XML and MS HTML IS user authorization Full database backup of the web frame
Higher performance (improved speed) through using the aggregation archives when creating reports over a longer period
Higher level of security thanks to integrated, role based user authorization
Added Value
Unrestricted / Siemens AG 2014. All Rights Reserved.
Process Historian & Information ServerLicensing
Keep already purchased WinCC Archive licenses from previous versionsGet equal amount of PH Archive licenses for no charge
Get OS Archive license and PH Archive license on the same USB license stick
OS archive licensesOS archive licenses PH archive licensesIS licensesPH archive licenses
IS licenses
New PCS 7 V8.0/V8.1 projects Upgrade of PCS 7 projects to V8.0/V8.1
Unrestricted / Siemens AG 2014. All Rights Reserved.
Process Historian Hardware-Recommendation: IPC547E
Processor Intel Core i7-4770S 3,1 (3,9) GHz;
RAM Up to 32 GB expandable, DDR3-1600 SDRAM
Drives 240 GB SSD Operating system and Software1 X 500 GB1 X 1 TB2 X 1 TBRAID1: 2 X 1 TB in removable framesRAID5: 3 X 1 TB in removable frames
PH Database and Transaction log
RAID Controller
SATA RAID Controller onboard
maximum archiving load of 1000 samples per second
Recommendation: Use of a SSD Hard drive for the Operating system
Unrestricted / Siemens AG 2014. All Rights Reserved.
Process HistorianSoftware-Requirements
Release of Process Historian exclusively for 64 Bit operating system
Windows Server 2008 R2 + SP1, Windows Server 2012 SP1 and Microsoft SQL-Server 2008 R2 Standard and Enterprise Editions are supported.
Pre-installation of MS Message Queuing
PH-Ready and PH-Witness can be installed on Windows Operating system that are supported by OS.
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information ServerSoftware-Requirements
Suitable Microsoft operating systems and software components are shown in the following table
Software Logical Address space
Windows Server 2003 SP2 32-bit
Windows Server 2008 SP2 32-bit
Windows 7 SP1 32-bit and 64-bit
Windows Server 2008 R2 SP1 64-bit
The Information Server requires the Services of Internet Information Services (IIS). During PH-Installation the DotNet Framework 4.5 is installed and DotNet Framework 3.5 must be present before Installing the PH and the IS.
Unrestricted / Siemens AG 2014. All Rights Reserved.
Information Server ClientSoftware-Requirements
Support the same operating system as for the Information Server. Information Server Office Add-in Internet Explorer V11
IS Client Office AddInVisual Studio Tools for Office (VSTO Runtime)Since PCS 7 V8.0 SP1 the component VSTO from PCS 7-setup is installed automatically.Supported Office-Applications: Excel, Word and (Power Point) Microsoft Office 2007 SP3 (32 Bit) Microsoft Office 2010 SP1 (32 Bit) Microsoft Office 2013 SP1 (32 Bit)
Unrestricted / Siemens AG 2014. All Rights Reserved.
Licenses
The PH and IS Upgrade License is included in the upgrade package of the OS server.You can upgrade an IS and a PH, a PH/IS or an OS server with this license
Product Remark Status
Process Historian and Information Server - Basic Package
Basic-Function-License for PH and IS, not separable
Process Historian - Basic Package Basic-Function-License for PH
Process Historian - Server Redundancy contains 2x Bundle license in the bundle: PH function & Redundancy License
2x Server -> Server Redundancy - Process Historian ConversionPack
Additive required for upgrade from PH to PH Single Redundant, requires second PH Basic Package
Process Historian - Archive BATCH Required on PH for archiving the BATCH Data
Process Historian - OPC UA Server Function-license of OPC UA Servers new
Information Server - Basic Package 1 x Function licenses for IS
Process Historian / Information Server Licenses PCS 7 V8.1, versioned
Unrestricted / Siemens AG 2014. All Rights Reserved.
Licenses
Information Server Licenses PCS 7 V8.1, unversioned
Product Remark Status
Information Server (1 Client) 1 x Function license for IS client to access to the IS server
Information Server (3Client) 3 x Function license for IS client to access to the IS server
Information Server (5 Client) 5 x Function license for IS client to access to the IS server
Information Server (10 Client) 10 xFunction license for IS client to access to the IS server
Information Server Datasource Access - (1 Source)
1 x Function license for using an OS Archive with the IS
Information Server Datasource Access - (3 Sources)
3 x Function license for using OS Archives with the IS
Unrestricted / Siemens AG 2014. All Rights Reserved.
Licenses
Upgrade Licenses PH / IS PCS 7 V8.0 to PCS 7 V8.1Product Remark Status
SIMATIC PCS 7 - Upgrade Package OS Server - V8.0 -> V8.1
- Process Historian Archive - BATCH V8.0 (SL) -> Process Historian Archive - BATCH V8.1 (SL)
and- Information Server V8.0 (SL) -> SIMATIC
Information Server 2014 (SL)or
- Process Historian Server V8.0 (SL) -> Process Historian Server 2014 (SL)
or- Process Historian Server Redu. V8.0 (SL) ->
Process Historian Server Redundancy V8.1 (SL) or
- Process Historian and Inform. Serv. V8.0 (SL) -> Process Historian and Information Server V8.1 (SL)
new
Unrestricted / Siemens AG 2014. All Rights Reserved.
Svitlana Schmitt
Marketing Manager
PD PA S AE MP
Siemensallee 84
76187 Karlsruhe
Phone: 0721 595 4342
E-Mail: [email protected]
Thank you for your attention!
siemens.com/answers