AB-PQF / UPB FLOWCHART SYMBOLOGY
INDEX OF REVISIONS
REV DESCRIPTION AND/OR REVISED SHEETS
0 ORIGINAL ISSUE
A REVISED WHERE INDICATED
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 CLIENT OR USER
COMPERJ SHEET
1 of 43 JOB OR PROJECT
RIO DE JANEIRO PETROCHEMICAL COMPLEX CC
- AREA OR UNIT GENERAL WITHOUT SCALE
ORIGINAL REV. A REV. B REV. C REV. D REV. E REV. F REV. G REV. H
DATE 21-12-07 16-01-08
DESIGN AB-PQF/UPB/ES AB-PQF/UPB/ES
EXECUTION JOACY JOACY
CHECK JOÃO PAULO JOÃO PAULO
APPROVAL FERNANDO FERNANDO
THE DATA, OR PART THEREOF, ARE PETROBRAS PROPERTY AND THUS MUST NOT BE USED IN ANY WAY WITHOUT PERMISSION
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 2 of 43
TITLE
FLOWCHART SYMBOLOGY
ANNEX A – Simbology for Drawing Lines
1 – Lines of Instrumentation
Simbology Description Name / Attributes
Line Supply or push (Connection to Process) (1) Linha de Suprimento ou Impulso (Conexão ao Processo) (1)
Th.=0,1 mm Color=green
Pneumatic Signal Sinal Pneumático
SPN
Electrical Signal Sinal Elétrico
SNE
L L L
Hidraulyc Signal Sinal Hidráulico
SNH
X XX
Capillary Tube Tubo Capilar
TBC
Eletromagnetic Signal or Sonic (Guided Transmission) Sinal Eletromagnético ou Sônico (Transmissão Guiada)
SEM
Eletromagnetic Signal or Sonic (Transmission not Guided) Sinal Eletromagnético ou Sônico (Transmissão Guiada)
SMN
Link configured internally to the sistem (Connection of Software) Ligação Configurada Internamente ao Sistema (Ligação de Software)
LCI
Mechanical Connection Ligação Mecânica
LIM
Pneumatic Binary Signal Sinal Binário Pneumático
SBP
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 3 of 43
TITLE
FLOWCHART SYMBOLOGY
Electrical Binary Signal Sinal Binário Elétrico
SBE
Signal to be defined
Sinal a Ser Definido SSD
2 – PIPING SYMBOLOGY
Symbology Description Attributes
Primary Line (Main)
Linha Primária Principal Th.=0,3 mm Color=yellow
Secondary Line
Linha Secundária Th.=0,2 mm Color=yellow
3 – Heating and Insulation of Piping
Symbology Description Name
Piping with Isolation
Tubulação com Isolamento TCI
Piping with Electrical Resistance Heating
Tubulação com Aquecimento por Resistência Elétrica TRE
Piping with Steam Heating External
Tubulação com Aquecimento Externo à Vapor TAE
Piping with Internal Steam Heating
Tubulação com Aquecimento Interno à Vapor TAI
Piping with Induction Heating Electric
Tubulação com Aquecimento por Indução Elétrica
TIE
Piping with Heating Jacket
Tubulação com Camisa de Aquecimento TCC
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 4 of 43
TITLE
FLOWCHART SYMBOLOGY
ANEXO B – Symbology for Piping Components
1 - Valves
Symbology Description Name
Gate Valve
Válvula Gaveta GVT
Globe Valve
Válvula Globo GLB
Ball Valve
Válvula Esfera ESF
Butterfly Valve
Válvula Borboleta BRB
Check Valve
Válvula de Retenção Simples RET
Stop Check Valve
Válvula de Retenção e Fechamento VRF
Swing-Check Valve
Válvula de Retenção Tipo Dupla Portinhola VDR
Needle Valve
Válvula Agulha AGL
Slide Valve
Válvula Guilhotina ou Comporta VGC
Quick Closing Valve
Válvula de Fechamento Rápido FRP
Plug Valve
Válvula Macho MCH
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 5 of 43
TITLE
FLOWCHART SYMBOLOGY
Manual Control Valve
Válvula de Controle Manual VCM
S
Solenoid Valve
Válvula Solenóide de Tubulação VST
Diaphragm Valve
Válvula Diafragma DFG
Way Valve
Válvula de Três Vias V3V
Ways Valve
Válvula de Quatro Vias V4V
Angle with Manual Control Valve
Válvula Angular Fixa VA1
Angle with Manual Control
Válvula Angular Ajustável
VA2
Foot with Filter Valve
Válvula de Pé ou Fundo com Filtro VPF
Inverted Plug Valve
Válvula de Encaixe Invertido VEI
Double Block and Drain Plug Valve
Válvula de Encaixe Duplo Bloqueio e Dreno Incorporado
VED
“Y” Globe Valve
Válvula Globo em “Y” VGY
With Buoy Control Valve
Válvula Comando de Bóia VCB
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 6 of 43
TITLE
FLOWCHART SYMBOLOGY
Motorized Valve
Válvula Motorizada VMT
Damper Valve
Válvula Defletora (Damper ou Lover) DFL
Ball Three Way Valve
Válvula Esfera de Três Vias E3V
2 – Accessories of piping
Simbology Description Name
Pulsation Damper
Absorvedor de Pulsação ABP
Spray Nozzle
Borrifador ou Espargidor BOR
Exhaust Head
Cabeçote de Exaustão CBE
Hose Connection
Conexão para Mangueira (Engate Rápido) COM
Flame Arrestor
Corta Chama CCH
Spectacle Flange (Close)
Figura Oito Fechada F8F
Spectacle Flange (Open)
Figura Oito (Aberta) F8A
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 7 of 43
TITLE
FLOWCHART SYMBOLOGY
Filter type “T”
Filtro em “T” FTT
Filter type “Y”
Filtro em “Y” FTY
Filter of Vertical Basket
Filtro de Cesta Vertical FTC
Sample Cooler
Resfriador de Amostra RAM
Filter (Simple Exchange Basket)
Filtro de Cestas Intercambiáveis Simples FTS
Filter (Double Exchange Basket)
Filtro de Cestas Intercambiáveis Duplas FTD
Temporary Filter
Filtro Temporário FTE
Air Filter for Compressor Suction
Filtro de Ar para Sucção de Compressor FTA
Hidrant with 2 outlets
Hidrante com Duas Saídas H2S
Hidrant with 4 outlets
Hidrante com 4 Saídas H4S
Hidrant with 6 outlets
Hidrante com 6 Saídas H6S
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 8 of 43
TITLE
FLOWCHART SYMBOLOGY
Hidrant with monitor (*)
(*) 2 outputs with water or foam
Hidrante com Duas Saídas com Canhão Monitor
H2C
Hidrant with monitor (*)
(*) 4 outputs with water or foam
Hidrante com Quatro Saídas com Canhão Monitor
H4C
Hidrant with monitor (*)
(*) 6 outputs with water or foam
Hidrante com Seis Saídas com Canhão Monitor
H6C
Water Monitor Cannnon
Canhão Monitor de Água CMA
Foam Monitor Cannon
Canhão Monitor de Espuma CME
Foam Generator Jet
Esguicho Formador de Espuma ESG
Foam Liquid Generator Recipient
Bombona de Líquido Gerador de Espuma
LGE
Flexible Hose
Mangote Flexível MGF
Steam Trap
Purgador de Vapor PUR
Racket
Raquete RQT
Reduction
Redução RED
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 9 of 43
TITLE
FLOWCHART SYMBOLOGY
Silencer
Silenciador
SIL
Silencer in Line
Silenciador em Linha SLL
Air Trap
Ventosa VTS
Welded Cap
Tampão Soldado TMS
Screwed Cap
Tampão Roscado TMR
Plug
Bujão BUJ
Expansion Joint
Junta de Expansão JTE
Atmospheric Breathing
Respiro Atmosférico RSP
In-Line Mixer Straight Type
Misturador de Linha Tipo reto MTL
Piping Special Symbol
Símbolo Especial de Tubulação SET
Removable Spool
Carretel Removível CRT
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 10 of 43
TITLE
FLOWCHART SYMBOLOGY
Shower
Chuveiro CHU
Eye-Wash
Lava-Olho LVO
“T” Grilled
“T” Gradeado TGR
“T” Mixer
“T’ Misturador TMT
Witch Hat
Chapéu de Brucha CHB
Connection for Swivel
Tampão Roscado CPS
In-Line Separator
Bujão SEL
Siphon
Sifão SIF
Injection Pot
Pote de Injeção PIJ
Gas Burner
Bico de Gás BCG
ANEXO C – Simbology for Triggers and Machines
1 – Triggers
Simbology Description Name
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 11 of 43
TITLE
FLOWCHART SYMBOLOGY
Motor
Motor
MTR
Internal Combustion Engine
Motor de Combustão Interna MCI
Turbine
Turbina TRB
2 – Pumps
Simbology Description Name
Centrifugal Pump
Bomba Centrífuga CTF
Alternative Pump
Bomba Alternativa ALT
Dosing Pump
Bomba Dosadora DOS
Vertical Pump
Bomba Vertical BVT
Rotary Pump
Bomba Rotativa RTV
Well Pump
Bomba de Poço BPC
3 – Compressors
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 12 of 43
TITLE
FLOWCHART SYMBOLOGY
Simbology Description Name
Centrifugue or Axial Compressor (1 Stage)
Compressor Centrífugo ou Axial (1 Estágio)
CCT1
Centrifugue or Axial Compressor (2 Stage)
Compressor Centrífugo ou (2 Estágios)
CCT2
Centrifugue or Axial Compressor (3 Stage)
Compressor Centrífugo ou Axial (3 Estágios) CCT3
Alternative Compressor (1 Stage)
Compressor Alternativo (1 Estágio)
CAL1
Alternative Compressor (2 Stage)
Compressor Alternativo (2 Estágios)
CAL2
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 13 of 43
TITLE
FLOWCHART SYMBOLOGY
Alternative Compressor (3 Stage)
Compressor Alternativo (3 Estágios) CAL3
Rotary Compressor (1 Stage)
Compressor Rotativo (1 Estágio)
CRT1
Rotary Compressor (2 Stage)
Compressor Rotativo (2 Estágios) CRT2
Rotary Compressor (3 Stage)
Compressor Rotativo (3 Estágios) CRT3
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 14 of 43
TITLE
FLOWCHART SYMBOLOGY
4 – Others
Simbology Description Name
Mixer (Agitator)
Agitador (Misturador) AGT
Fan
Soprador (Ventilador) SPD
Centrifugal (Centrifugal Separator)
Centrifugador (Separador Centrífugo)
CNF
Speed Variator
Variador de Velocidade VAV
ANEXO D – Simbology for Equipment
1 – Equipment of Thermal Exchange
Simbology Description Name
Condenser or Air Cooler
Resfriador a Ar (Condensador) RFA
Barometric Condenser
Condensador Barométrico CBR
Furnace – Type 1
Forno - Tipo 1 FR1
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 15 of 43
TITLE
FLOWCHART SYMBOLOGY
Furnace – Type 2
Forno – Tipo 2
FR2
Furnace – Type 3
Forno – Tipo 3 (3)
FR3
Electric Furnace
Forno Elétrico FEL
Reformer
Reformador
RF1
Heat Exchanger and Condenser
(Tube Flow-Simple Type – Type 1)
Permutador e Condensador de Feixe Tubular Simples – Tipo 1
PF1
Heat Exchanger and Condenser
(Tube Flow,Simple Type – Type 2
Permutador e Condensador de Feixe Tubular Simples – Tipo 2
PF2
Heat Exchanger and Condenser “U” Tube
Permutador e Condensador de Feixe Tubular com Tubo em “U”
PFU
Electric Heater Heat Exchange
Permutador com Aquecimento Elétrico
PAE
A
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 16 of 43
TITLE
FLOWCHART SYMBOLOGY
Flare Vaporizer
Vaporizador de Tocha
VPT
Double Pipe Heat Exchanger (Simple)
Permutador de Tubos Concêntricos Simples
PTC
Double Pipe Heat Exchanger (Multiple)
Permutador de Tubos Concêntricos Múltiplo
PTM
Plate Heat Exchanger
Permutador de Placas
PDP
Heat Recovery Unit
Recuperador de Calor
REC
Multiflow Heat Exchanger
Trocador Multifluxo
TMF
Exchanger with Boot
Trocador com Bota
TBT
A
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 17 of 43
TITLE
FLOWCHART SYMBOLOGY
Reboiler Simple
Refervedor Simples
RFV
Reboiler Type “Kettle”
Refervedor Tipo “Kettle”
RKE
Refrigerator - Type 1
Refrigerador – Tipo 1
REF1
Refrigerator – Type 2
Refrigerador – Tipo 2
REF2
Reformer Steam Generator
Gerador de Vapor do Reformador
GVR
Electric Bayonet
Baionete Elétrica
BEL
2 – Vessels, tank, collumns and reactors
Simbology Description Name
Gasometer
Gasômetro GSM
Dome Roof Tank
Tanque com Teto Tipo Domo TQD
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 18 of 43
TITLE
FLOWCHART SYMBOLOGY
Conical Roof Tank
Tanque com Teto Cônico TQC
Plan Roof Tank
Tanque com Teto Plano TTP
Open Tank
Tanque sem Teto TQS
Floating Roof Tank
Tanque com Teto Flutuante TQF
Simple Horizontal Vessel
Vaso Horizontal Simples VHS
Simple Vertical Vessel
Vaso Vertical Simples VVS
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 19 of 43
TITLE
FLOWCHART SYMBOLOGY
Vertical With Flat Top
Vaso Vertical com Tampo Plano VTP
Vertical With Conical Transition
Vaso Vertical com Transição Cônica VTC
Pressure Vessel Spherical
Vaso Esférico VSF
Reactor
Reator RTR
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 20 of 43
TITLE
FLOWCHART SYMBOLOGY
Desmetanizer Column
Torre Desmetanizadora TDM
Destillation or Rectifying Fractioning Column
Torre de Destilação, de Retificação ou de Fracionamento
TDT
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 21 of 43
TITLE
FLOWCHART SYMBOLOGY
Column with two section
Torre com Duas Seções T2S
Column with three sections
Torre com Três Seções
T3S
3 – Others Equipament
Simbology Description Name
Ejector
Ejetor
EJT
Stack
Chaminé CHM
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 22 of 43
TITLE
FLOWCHART SYMBOLOGY
Tulip Flare
Tocha Tipo Tulipa TUL
Molecular Seal Flare
Tocha Tipo Selo Molecular (3) TSM
Fluidal Seal Flare
Tocha Tipo Selo Fluídico TSF
Flare
Tocha Tipo Flare TTF
Multipoint Flare Type
Tocha Tipo Multiflare MUL
Gas Cylinder
Gas Cilíndro CLD
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 23 of 43
TITLE
FLOWCHART SYMBOLOGY
Water-Oil Separator
Separador de Água e Óleo SAO
Pig Launcher/Reciever
Lançador ou Recebedor de “PIG” LRP
Open Out Put Pipe
Tubo de Despejo Aberto
TDA
Closed Out Put Pipe
Tubo de Despejo Fechado TDF
Head of Well Drought
Cabeça de Poço Seca CP1
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 24 of 43
TITLE
FLOWCHART SYMBOLOGY
Sea Chest
Caixa de Mar CMR
Head of Submarine Well
Cabeça de Poço Submarina
CP2
Hydrocyclone
Hidrociclone HCL
Silo
Silo SLO
4 – Components of Equipment
Simbology Description Name
Tray - Type 1
Bandeja – Tipo 1 BD1
Tray – Type 2
Bandeja – Tipo 2 BD2
Tray – Type 3
Bandeja – Tipo 3 BD3
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 25 of 43
TITLE
FLOWCHART SYMBOLOGY
Tray - Type 4
Bandeja – Tipo 4 BD4
Tray - Type 5
Bandeja – Tipo 5 BD5
Distributor – Type 1
Distribuidor – Tipo 1 DT1
Distributor - Type 2
Distribuidor – Tipo 2 DT2
Distributor - Type 3
Distribuidor – Tipo 3 DT3
Distributor - Type 4
Distribuidor – Tipo 4 DT4
Distributor - Tipo 5
Distribuidor – Tipo 5 DT5
Distributor - Tipo 6
Distribuidor – Tipo 6 DT6
Distributor - Tipo 7
Distribuidor – Tipo 7 DT7
Demisting Pad – Type 1
Eliminador de Névoa ou Demister – Tipo 1 DM1
Demisting Pad - Type 2
Eliminador de Névoa ou Demister – Tipo 2
DM2
Demisting Pad – Type 3
Eliminador de Névoa ou Demister – Tipo 3 DM3
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 26 of 43
TITLE
FLOWCHART SYMBOLOGY
Bottom Support - Type 1
Suporte de Leito – Tipo 1 SL1
Bottom Support - Type 2
Suporte de Leito – Tipo 2 SL2
Bottom Support - Type 3
Suporte de Leito – Tipo 3 SL3
Distributor Plate
Placa Distribuidora PLD
Chicane
Chicana CHC
Vortex-Breaker
Quebra Vórtice QVT
Leito
Bottom LTO
Additional Sectional (Drainage Shoe)
Seção Adicional (Bota de Drenagem) SAD
Coil Furnace
Serpentina do Forno SPF
Damper Furnace
Damper do Forno DPR
Burner for Furnace or “Plenum”
Queimador para Forno ou “Plenum” QUE
Nozzle - Type 1
Bocal Tipo 1 BC1
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 27 of 43
TITLE
FLOWCHART SYMBOLOGY
Nozzle - Type 2
Bocal Tipo 2 BC2
Nozzle - Type 3
Bocal Tipo 3 BC3
Nozzle - Type 4
Bocal Tipo 4 BC4
Pipe Reform
Tubo do Reformador TRF
Pipe for Water Captation
Tubulão para Captação de Água
TCA
Personnel Protection or Isolation of Procedure for Equipment
Proteção Pessoal ou Isolamento de Processo para Equipamentos
PPI
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 28 of 43
TITLE
FLOWCHART SYMBOLOGY
ANNEX E – Instrumentation Symbols
1 – Instruments Symbols or Programmed Functions
1.1 - Simple Instruments
Simbology Description Name
Field Instrument (Instrumento no Campo) ISC
Instrument in Front of Centre Panel (Instrumento na Frente do Painel Central) IPC
Instrument in Front of Local Panel (Instrumento na Frente do Painel Local) IPL
Instrument in Rear of Centre Panel (Instrumento Atrás do Painel Central) IAC
Instrument in Rear of Local Panel (Instrumento Atrás do Painel Local)
IAL
1.2 - Shared Instruments (DCS)
Field Instrument (Instrumento no Campo) CIC
Instrument in Front of Centre Panel (Instrumento na Frente do Painel Central) CPC
Instrument in Front of Local Panel (Instrumento na Frente do Painel Local) CPL
Instrument in Rear of Centre Panel (Instrumento Atrás do Painel Central) CAC
Instrument in Rear of Local Panel (Instrumento Atrás do Painel Local)
CAL
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 29 of 43
TITLE
FLOWCHART SYMBOLOGY
1.3 - Process Computer type Instruments
Field Instrument (Instrumento no Campo) PSC
Instrument in Front of Centre Panel (Instrumento na Frente do Painel Central) PPC
Instrument in Front of Local Panel (Instrumento na Frente do Painel Local) PPL
Instrument in Rear of Centre Panel (Instrumento Atrás do Painel Central) PAC
Instrument in Rear of Local Panel (Instrumento Atrás do Painel Local)
PAL
1.4 - Programmable Controller Type Instruments
Field Instrument (Instrumento no Campo) RIC
Instrument in Front of Centre Panel (Instrumento na Frente do Painel Central) RPC
Instrument in Front of Local Panel (Instrumento na Frente do Painel Local) RPL
Instrument in Rear of Centre Panel (Instrumento Atrás do Painel Central) RAC
Instrument in Rear of Local Panel (Instrumento Atrás do Painel Local)
RAL
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 30 of 43
TITLE
FLOWCHART SYMBOLOGY
2 – Control Valves
Simbology Description Name
General Valve (Válvula Geral) GVT1
Valve Globe (Válvula Globo) GLB1
Ball Valve (Válvula Esfera) ESF1
Butterfly Valve (Válvula Borboleta)
BRB1
Diaphragm Valve (Válvula Diafragama) DFG1
Three-Way Valve (Válvula de Três Vias) V3V1
Four-Way Valve (Válvula de Quatro Vias) V4V1
Angle Valve (Válvula Angular) VAN1
Four-Way Valve ( used for switching pneumatic signals) (Válvula de Quatro Vias (usada para comutação de sinais pneumáticos)
4VC
Damper or Louver - Tipo 1 (Vàlvula Defletora) DFL1
Damper or Louver - Tipo 2 (Vàlvula Defletora) DFL2
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 31 of 43
TITLE
FLOWCHART SYMBOLOGY
Minimum Flow Automatic Control Valve (Válvula de Controle Automática para Fluxo Mínimo) VCA1
3 - Actuators
Simbology Description Name
Diaphragm, Spring-Opposed, With or Without Pilot (Diafragma, com Retorno por Mola, com ou sem Piloto)
DIA
Diaphragm, Spring-Opposed, With Positioner (Diafragma, com Retorno por Mola, com Posicionador)
DFP
Diaphragm Pressure-Balanced (Diafragma Balanceado) DBL
Cylinder Spring-Opposed, General Cylinder or Double-Action Cylinder (Cilindro com Retorno por Mola, Cilindro Qualquer ou Cilindro de Dupla Função)
CRM
S
Solenoid (Solenóide) SLN
S S
Dual Solenoids Switching 4-Way Valve
(Solenóide Duplo) SLD
M
Rotary Motor (Electric, Pneumatic or Hydraulic) (Motor Rotativo (Elétrico, Pneumático ou Hidráulico)
MRT
Spring, Weight or Integral Pilot (Used only for Pressure Relief and Safety Valves) (Mola, Peso ou Piloto Integral (Utilizado apenas para Válvulas de Alívio ou Segurança))
MOL
Hand Actuator or Hand-Wheel
(Manual Local ou Volante) AML
P
Pilot (Piloto) PLT
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 32 of 43
TITLE
FLOWCHART SYMBOLOGY
W
Weight (Peso) PSO
Buoy Type (Tipo Bóia) ATB
EH
Electro-hydraulic
(Eletrohidráulico) ELH
4 – Self-Actuated Devices
Simbology Description Name
Backpressure Regulator, Self-Contained (Válvula Reguladora de Pressão com Tomada Interna à Montante)
VRM
Pressure-Reducing Regulator, Self-Contained (Válvula Reguladora de Pressão com Tomada Interna à Jusante)
VRJ
Backpressure regulator With external Pressure Tap (Válvula Reguladora de Pressão com Tomada Externa à Montante)
VEM
Pressure-Reducing Regulator With External Pressure Tap (Válvula Reguladora de Pressão com Tomada Externa à Jusante)
VEJ
Pressure-Reducing Regulator, Self-Contained , With Hand-wheel Adjustable Set Point (Válvula Reguladora de Pressão à Jusante com Tomada Interna e Ajuste por Volante)
VVJ
Pressure-Reducing Regulator With Integral Outlet Pressure Relief Valve (Válvula Reguladora de Pressão com Válvula de Alívio)
VRA
Differential-Pressure-Reducing Regulator With internal and External Pressure Taps (Válvula Reguladora de Pressão Diferencial)
VPD
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 33 of 43
TITLE
FLOWCHART SYMBOLOGY
Temperature Regulator, Filled-System Type (Válvula Termostática Atuada por Sistema Selado de Expansão (Tipo Bulbo))
VTE
Pressure Relief or Safety Valve, Straight- Through Pattern, Spring or Weight-Loaded, or With Integral Pilot (Válvula de Segurança ou Alívio Tipo Passagem Reta)
PSR
Hand Control valve in Process Line (Válvula Manual de Controle em Linha) VMC
Restriction Orifice Drilled in Valve
(Orifício de Restrição Usinado no Corpo da Válvula)
ORV
Pressure Relief or Safety Valve or Vacuum Relief Valve (Válvula de Segurança e Alívio de Pressão ou Válvula de Alívio de Vácuo)
PSV
Pressure and Vacuum Relief Valve (Válvula de Alívio de Pressão e Vácuo)
VPV
Rupture Disk (Disco de Ruptura por Pressão) DRP
Rupture Disk for vacuum Relief (Disco de Ruptura por Vácuo) DRV
Fusible Plug (“Plug” Fusível) PLG
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 34 of 43
TITLE
FLOWCHART SYMBOLOGY
5 – Primary Element Symbols
Simbology Description Name
General symbol For Flow Primary Element (Símbolo Geral para Elementos Primários de Vazão) EPV
Test Connections type tap in the flange or in the corner (without orifice plate) (Conexões para Teste Tipo Tomada no Flange ou no Canto (Sem Placa de Orifício))
FLG
Orifice Plate With Taps in the Flange , in the Corner on in the Vena Contracta (Placa de Orifício com Tomadas no Flange, no Canto ou na Vena Contracta)
PLO
Orifice Plate in Quick-change Fitting (Dispositivo para Troca Rápida de Placas de Orifício)
TPL
Single Pitot Tube (Tubo Pitot Simples) TPS
Venturi Tube
(Tubo Venturi) TVT
Averaging Pitot Tube (Tubo Pitot de Média ou Annubar) TPM
Flume (Canal Aberto) CAB
Weir (Vertedor) VTD
Turbine Type Flowmeter (Medidor de Vazão Tipo Turbina) MTT
Positive-Displacement Flowmeter (Medidor de Vazão Tipo Deslocamento Positivo) MDP
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 35 of 43
TITLE
FLOWCHART SYMBOLOGY
Variable Area Flowmeter (Medidor de Vazão Tipo Área Variável ou Rotâmetro) MAV
Magnetic Flowmeter (Medidor de Vazão Tipo Magnético) MTM
Sonic Flowmeter - “Doppler” or Transient time” (Medidor de Vazão Tipo Sônico)
MTS
Vortex Flowmeter (Sensor de Vórtice ou Vortex) SVT
Target Flowmeter (Sensor Tipo Alvo ou Target) STA
Flow Nozzle (Bocal de Vazão) BOV
Flow Straightening Vane (Retificador de Fluxo ou “Straight Vane”) STV
6 – Other General Symbols
Simbology Description Name
Field Pilot Light (Lâmpada Piloto de Campo) LP1
Pilot Light in the Centre Panel (Lâmpada Piloto de Painel Central) LP2
Pilot Light in the Local panel (Lâmpada Piloto de Painel Local) LP3
Purge or Fluid Injection Device (Dispositivo para Purga ou Injeção de Fluido) DPI
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 36 of 43
TITLE
FLOWCHART SYMBOLOGY
Manual Local or Remote Reset (Rearme Manual Local ou Remoto) RML
Undefined Logic Safety Interlock (Intertravamento Lógico Indefinido) ILI
Interlock “E” (Intertravamento “E”)
ITE
Interlock “OU” (Intertravamento “OU”) IOU
Timer (Temporizador) TEP
Emergency Shutdown Set-Point (Nível de Parada de Emergência) ESD
Diaphragm Seal (Selo Diafragma) SDF
Sound Alarm (Alarme Sonoro) ALS
ou
Set-point (Ponto de Controle ou Valor Desejado) SPT
7 – Function Blocks – Function Designations
Simbologia Descrição Nome
Summing (Função Soma) FSM
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 37 of 43
TITLE
FLOWCHART SYMBOLOGY
Averaging (Função Média) FMD
Difference (Função Diferença) FDF
Proportional – Type 1 (Função Proporcional - Tipo 1) FP1
Proportional – Type 2 (Função Proporcional - Tipo 2) FP2
Proportional – Type 3 (Função Proporcional - Tipo 3) FP3
Integral (Função Integral) FIN
Derivative (Função Derivativo) FDE
Multiplying (Função Multiplicação) FML
Dividing (Função Divisão) FDV
Root Extraction (Função Radiciação) FRD
Exponential (Função Exponenciação) FEX
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 38 of 43
TITLE
FLOWCHART SYMBOLOGY
Nonlinear or Unspecified Function (Função Não Linear ou Não Específica) FNL
Time Function (Função Tempo) FTP
High Selecting (Função Seleção de Alta) FSA
Low Selecting (Função Seleção de Baixa) FSB
High Limiting (Função Limite Superior) FLS
Low Limiting (Função Limite Inferior) FLI
Set-Point High e Low Limiting (Função Limite Superior e Inferior de “Set-Point”) FSI
Reverse Proportional (Função Inversamente Proporcional)
FIP
Velocity Limiter (Função Limite da Taxa de Variação no Tempo) FLT
Bias – Type 1 (Função Polarização ou Bias - Tipo 1) FB1
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 39 of 43
TITLE
FLOWCHART SYMBOLOGY
Bias – Type 2 (Função Polarização ou Bias - Tipo 2) FB2
Bias – Type 3 (Função Polarização ou Bias - Tipo 3) FB3
Convert (Função de Conversão) FCV
Any Function (Função Qualquer) FQQ
8 – Typical Arrangements
Simbologia Descrição Nome
Variable Area Flowmeter With Pressure-Reducing regulator – Type 1 (Medidor de Vazão Tipo Área Variável com Válvula Reguladora Manual - Tipo 1)
MV1
Variable Area Flowmeter With Hand Control valve – Type 2
(Medidor de Vazão Tipo Área Variável com Válvula Reguladora Manual - Tipo 2)
MV2
Variable Area Flowmeter With Pressure-Reducing regulator, Self-Contained – Type 1 (Medidor de Vazão Tipo Área Variável com Válvula Reguladora/Tomada Interna - Tipo 1)
MT1
Variable Area Flowmeter With Pressure-Reducing, self contained (Medidor de Vazão Tipo Área Variável com Válvula Reguladora/Tomada Interna - Tipo 2)
MT2
Control Valve Arrangement – Type 1 (Estação de Controle - Tipo 1) EC1
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 40 of 43
TITLE
FLOWCHART SYMBOLOGY
Control Valve Arrangement – Type 2 (Estação de Controle - Tipo 2) EC2
Control Valve Arrangement – Type 3 (Estação de Controle - Tipo 3) EC3
Control Valve Arrangement – Type 3 (Estação de Controle - Tipo 4)
EC4
Orifice Plate With Transmitter (Placa com Instrumento)
PLI
Control Valve (Válvula de Controle)
VCT
ANNEX F – Utilities Symbols
Simbology Description Name
General (Geral)
SBU
Drain (Dreno)
DRN
Sample Point
(Amostrador) AMS
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 41 of 43
TITLE
FLOWCHART SYMBOLOGY
ANNEX G – Symbols For Operation Conditions
Simbology Description Name
Number of Flow (Número do Fluxo)
NFL
Temperature (Temperatura)
TMP
Pressure (Pressão)
PRS
Steam Flow Rate (Taxa de Vazão de Vapor)
VZV
Liquid Flow Rate (Taxa de vazão de Líquido)
VZL
Gas Flow Rate (Taxa de Vazão de Gás)
VZG
Duty Indicating (Indicação de Serviço)
CTR
Specific Gravity, Specific Weight or Molecular Weight (Densidade Específica, Peso Específico ou Peso Molecular)
DNS
ANNEX H – Other Symbols
Simbology Description Name
Line Interruption (Interrupção de Linha)
INL
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 42 of 43
TITLE
FLOWCHART SYMBOLOGY
From/To othex Flowchart of the same Unit (De/Para Outro Fluxograma da Mesma Unidade) BLD
From/To Other Flowchart of Other Unit (De/Para Outro Fluxograma de Outra Unidade)
BLU
System or process End (Término do Sistema ou Processo) TFL
System or Process Starting (Início do Sistema ou Processo) IFL
Line With Slope Type 1 (Linha com Caimento Tipo 1)
LC1
SLOPE
Line With Slope Type 2 (Linha com Caimento Tipo 2)
LC2
Spec Break (Quebra de Especificação)
QSP
Primary Flow (Fluxo Primário) FPR
Secondary Flow (Fluxo secundário) FSE
Floor (Representação de Piso) PIS
TECHNICAL SPECIFICATION No.
I-ET-6000.67-0000-941-PDY-012 REV.
A
AREA OR UNIT RIO DE JANEIRO PETROCHEMICAL COMPLEX SHEET 43 of 43
TITLE
FLOWCHART SYMBOLOGY
REFERENCE DOCUMENT:
Note : This document is an english version of the I-ET-5000.00-2300-900-PPC-002 “ SIMBOLOGIA FLUXOGRAMA ” issued by CENPES .
at 06/09/2004.