+ All Categories
Home > Documents > Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A....

Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A....

Date post: 24-Jul-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
6
Simply straightforward NobelParallel Conical Connection Simply straightforwa NobelP arallel Conica
Transcript
Page 1: Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implants

Simply straightforwardNobelParallel™ Conical ConnectionSimply straightforwaNobelParallel™ Conica

Page 2: Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implants

Stability and fl exibility in parallel

Innovation based on fi fty years of experienceWhen Professor Per-Ingvar Brånemark placed the very fi rst dental implants half a century ago, they were parallel-walled. The new NobelParallel Conical Connection benefi ts from fi fty years of research and innovation, combining the greatest features of the successful Brånemark and NobelSpeedy implant systems.

The NobelParallel Conical Connection is straightforward in design and application. It offers extraordinary fl exibility that you’ll appreciate whether you’re an experienced clinician or new to implantology. The well-documented implant body provides high primary stability and allows for universal use in all bone qualities and a wide range of indications.

Effi cient treatment fl owA limited number of drills ensures a straightforward surgical protocol that can be fl exibly used in different bone densities.

Engineered for Immediate FunctionThe TiUnite surface, surgical protocol, tapered apex and threads from tip to platform are all designed to provide high primary stability and support the Immediate Function protocol.1,4 The NobelParallel Conical Connection apex design also allows for bi-cortical anchorage to obtain high primary stability in cases of reduced bone density.5

Universal useWell-documented implant body designed for universal use in all bone qualities and a wide range of indications.1,2,3

Brånemark System

NobelParallel CC

NobelSpeedy Groovy

Page 3: Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implants

Exceptional versatilityCover the majority of your cases with only one implant system – no matter if you’re placing implants in the anterior or posterior region1,2,6 or treating single-tooth, multiple-teeth or full-arch restorations.1,2,3,4,5,6,7

Access to innovative restorative solutions Take advantage of innovative solutions available only for Nobel Biocare’s conical connection. These include the cement-free NobelProcera ASC (angulated screw channel) Abutment and the NobelProcera FCZ (full-contour zirconia) Implant Crown. Experience the unique pick-up function of the Omnigrip tooling and its incredible grip on the screw.

Exceptional versatiCover the majority ofsystem – no matter ifanterior or posterior multiple-teeth or full-

Access to innovativTake advantage of infor Nobel Biocare’s cthe cement-free Nobchannel) Abutment a(full-contour zirconiaunique pick-up functits incredible grip on

Single tooth Multiple teeth Edentulous

Page 4: Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implants

Enhanced osseointegrationUnique oxidized TiUnite surface with grooves maintains implant stability through faster bone formation and promotes long-term success.8,9,10,11

Strong conical connectionThe advanced internal conical connection with hexagonal interlocking offers high mechanical strength.

Prosthetic-driven planningGet predictable results in less time and increase effi ciency throughout the entire treatment process.

Nobel Biocare’s integrated and effi cient treatment workfl ow offers a seamless process from diagnosis to restoration. Collaborate more effi ciently with your treatment partners and make your planned functional and esthetic outcome a reality.

TiUnite supports predictable and enhanced osseointegration. The unique combination of controlled titanium oxide texture and porosity makes bone grow directly onto and into the surface, starting in the grooves on the threads. Image © Schüpbach Ltd., Switzerland

“ I have been impressed with NobelParallel Conical Connection. The drill protocol is straight forward and the implant performs well in all bone qualities. I have found that NobelParallel Conical Connection provides excellent primary stability, making it a good implant choice for different indications.”

Dr. Sascha Jovanovic, Periodontist and Academic Chairman,

gIDE Institute, Los Angeles, USA.

Page 5: Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implants

A straightforward implant for universal use

Immediate implant placement in the posterior with single-tooth restoration26-year-old female patient.

Initial situationUpper molar is extracted atraumatically. Care is taken to maintain the septal bone for implant anchorage.

Immediate implant placementA NobelParallel Conical Connection RP implant (4.3×11.5 mm) is placed immediately in the extraction site using a NobelGuide surgical template with 2.0 mm Twist Drill for initial drilling and optimized positioning of the implant. High primary stability is achieved with a torque of 40 Ncm.

Tooth needs to be extracted due to decay.

The NobelClinician Software optimizes implant positioning.

X-ray shows correct positioning of implant.

Follow-up X-ray after delivery of fi nal crown four months post surgery.

HealingA healing abutment is placed for soft tissue contouring. Xenograft material is packed around the implant and covered by a resorbable membrane. The site is left healing for three months.

Final restorationIn the lab, an IPS e.max® ceramic crown is cemented to a titanium NobelProcera Abutment to produce a screw-retained crown with the desired transgingival emergence profi le.

Case courtesy of Dr. Léon Pariente and Dr. Karim Dada, Paris, France. Prosthetic work by Dr. Maxime Drossart and Asselin Bonichon.

Page 6: Simply straightforward Simply straightforwa …...Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implants

7803

2 A

GB

150

5 P

rinte

d in

Sw

eden

© N

obel

Bio

care

Ser

vice

s A

G, 2

014.

All

right

s re

serv

ed.

Nob

el B

ioca

re, t

he N

obel

Bio

care

log

otyp

e an

d al

l oth

er t

rade

mar

ks a

re, i

f no

thin

g e

lse

is s

tate

d or

is e

vide

nt f

rom

the

con

text

in a

cer

tain

cas

e, t

rade

mar

ks o

f N

obel

Bio

care

. Pro

duct

imag

es a

re n

ot n

eces

saril

y to

sca

le.

Dis

clai

mer

: Som

e pr

oduc

ts m

ay n

ot b

e re

gul

ator

y cl

eare

d/re

leas

ed f

or s

ale

in a

ll m

arke

ts. P

leas

e co

ntac

t th

e lo

cal N

obel

Bio

care

sal

es o

ffi c

e fo

r cu

rren

t pr

oduc

t as

sort

men

t an

d av

aila

bilit

y.

Visit us online for more information: nobelbiocare.com/nobelparallel

Learn from the pioneersTo develop the knowledge and skills needed to achieve the best possible results with the NobelParallel Conical Connection implant system, you need to learn from the best.

Whether you’re an experienced clinician or at the beginning of your implant career, you’ll fi nd an implant course tailored to your experience level in our progressive training offering.

Courses are held by renowned clinicians at locations all over the world.

Sign up today at:nobelbiocare.com/courses

References: 1. Agliardi EL, Pozzi A, Stappert CF, Benzi R, Romeo D, Gherlone E (2014). Immediate Fixed Rehabilitation of the Edentulous Maxilla: A Prospective Clinical and Radiological Study after 3 Years of Loading. Clin Implant Dent Relat Res, 16(2), 292–302. doi: 10.1111/j.1708-8208.2012.00482. 2. Malo P, Araujo Nobre MD, Lopes A, Rodrigues R (epub ahead 2014). Double Full-Arch Versus Single FullArch, Four Implant-Supported Rehabilitations: A Retrospective, 5-Year Cohort Study. J Prosthodont. doi: 10.1111/jopr.12228. 3. Malo P, Nobre M. Flap vs. fl apless surgical techniques at immediate implant function in predominantly soft bone for rehabilitation of partial edentulism: a prospective cohort study with follow-up of 1 year. Eur J Oral Implantol 2008;1(4):293-304. 4. Tallarico M, Vaccarella A, Marzi GC, Alviani A, Campana V. A prospective case-control clinical trial comparing 1- and 2-stage nobel biocare tiunite implants: resonance fre-quency analysis assessed by osstell mentor during integration. Quintessence Int. 2011;42(8):635-44. 5. Malo P, de Araujo Nobre M, Lopes A, Moss S. Posterior maxillary implants inserted with bicortical anchorage and placed in immediate function for partial or complete edentulous rehabilitations. A retrospective clinical study with a median follow-up of 7 years. Oral Maxillofac Surg. 2014 [Epub ahead]. 6. Pozzi A, Tallarico M, Marchetti M, Scarfo B, Esposito M. Computer-guided versus free-hand placement of immediately loaded dental implants: 1-year post-loading results of a multicentre randomised controlled trial. Eur J Oral Implantol. 2014;7(3):229-42. 7. Villa R, Rangert B. Immediate and early function of implants placed in extraction sockets of maxillary in-fected teeth: a pilot study. J Prosthet Dent 2007;97(6 Suppl):S96-S108. 8. Zechner W, Tangl S, Fürst G, Tepper G, Thams U, Mailath G, Watzek G. Osseous healing characteristics of three differ-ent implant types. Clin Oral Implants Res 2003;14(2):150-7. 9. Schüpbach P, Glauser R, Rocci A, Martignoni M, Sennerby L, Lundgren A, Gottlow J. The human bone-oxidized titanium implant interface: A light microscopic, scanning electron microscopic, back-scatter scanning electron microscopic, and energy-dispersive x-ray study of clinically retrieved dental implants. Clin Implant Dent Relat Res. 2005;7 Suppl 1:S36-43. 10. Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implants in hu-man jawbone. Int J Oral Maxillofac Implants 2003;18(3):341-8. 11. Hall J, Miranda-Burgos P, Sennerby L. Stimulation of directed bone growth at oxidized implants by macroscopic grooves: an in vivo study. Clin Implant Dent Relat Res 2005;7 (Suppl 1):76-82.

The benefi ts of Immediate Function– Faster solution (3 months vs. 10 months)– Less invasive intervention– Fewer clinical visits– Higher case acceptance– Greater patient satisfaction

Immediate patient satisfactionwith Immediate Function

The NobelParallel Conical Connection implant system is ideal for the immediate loading protocol as it is designed to provide primary stability and offers a versatile portfolio for temporary prosthetic solutions. Immediate placement combined with Immediate Function dramatically shortens the time to teeth for your patients and thereby increases their satisfaction.

9 months3 monthsSame day 4 5 6 7 8 10 months1 2

Only one surgery: tooth extraction, implant placement and temporary restoration in one visit.

Final crown is placed. Patient returns to normal lifestyle after just three months.

Provisional is cemented in place while wound heals.

Final crown is placed. Patient returns to normal lifestyle only after ten months.

First surgery: implant is placed and provisional is cemented in place again.

Second surgery: healed site is reopened, temporary restoration placed and provisional cemented in place again.

Fewer appointments make for happier patients

Immediate Function in extraction site

Conventional treatment

oration in one v visiti . t three months.


Recommended