42
1. Shell installation
Installation Shell First window that pop up when you insert the installation CD.
Press Install 800xA System Installation Shell
Then push Run on the other windows who are popping up.
Installation Shell
This will install the system shell on your computer.
Press Install
If not Microsoft.NET Framework 1.1 is not installed. This system shell wizard will automatically install this. When this is done system shell is finished with installation
43
2. Automated installation
Automated Installation
Press Run Automated Installation
System Planner This is the system planner. It will make the system you want for your network/computers.
Press Next
44
Choose Medium Choose CD/DVD and push DVD button in this window
45
System planner wizard
Press Next
Windows Here you can choose to use computer with Windows installed or if you want to install windows. If you choose to use preinstalled Windows read the System Installation guide for prerequisites before installing the software. We have used blank pcs This option makes a silent installation of Windows on c:\
Press Next
46
Nodes The wizard prompts you to choose a node setup. We have used single nodes, this creates the entire system on one computer.
Click for Single Engineering Node
Press Next
Connectivity Choose the device connectivity. In this system there is only the AC 800M.
Press Next
47
Field bus There is no usage of field bus.
Press Next
Workgroup/Domain In this system we use workgroups.
Press Next
48
Summary
Press Next
Installation
Press Next
49
System Configuration Choose workgroup, service account, password(Narvik8515) and system description.
Press Next
Summary Use the default settings on all but password. Choose an easier password. We have used abb here.
Press Next
50
Node Name Write in the name you want to use for your node/nodes
Press advanced If you want to change the IP-adress of the node/nodes. This is not necessary.
Press Next
System configuration IP Mark the box as shown in figure.
Press Next
51
System configuration IP This will show the IP-address for the node.
Press Next
Summary
Press Next
52
Setup Package Choose where to store the package. Use a diskette.
Press Next
Setup Package
Press Next
53
Setup Package For information about the setup package click on the link in the window.
Press Next
Finished You have now completed the System Planner and are ready to start with the installation of Industrial IT.
Press Finish
54
Computers without Windows If you are using computer without Windows, or want to reinstall Windows you have to choose this in the System Planner.
To do a silent installation insert the Windows CD and the diskette created in System Planner. This will install Windows automatically with the needed configurations on your local hard drive (c:\). NB: Silent installation will format all data on local hard drive (c:\)
Installing Windows with the help of the disk you have created in System Planner is the safest way of installing the system. This is because most of the settings needed by Industrial IT are set automatically.
When using a pre-installed Windows there are a lot of requisites that have to be done to your system. These are described in the System Installation book.
55
3. Industrial IT Single node installation guide The installation of Industrial IT on a computer is self-explaining. We have done a single node installation and created an installation guide. It is very important that you read the information given in each step, and that you have patience with each step. If you rush trough the installation and dont let each step finish it might compromise the rest of the installation.
Required assets for installing Industrial IT on a computer - Windows XP Professional CD - CD/DVD Package from ABB - Administrator rights on the computer - Microsoft Word and Excel 2003 or newer - Diskette with a system created in System Planner - Turn off Windows Firewall and other firewalls that are included in some virus
programs. - Download all hot fixes for your OS from Windows update on the Internet.
This must be done to have a stable and safe OS before you do anymore installation. Note: This can only be done if you are using computers with pre-installed Windows. If you are using a blank computer you will be prompted to install hot-fixes during the installation. This should be done.
If the installation should crash there is two ways of starting it again. - Restart PC, and the installation process should continue. - The other way is to manually restart it as shown in figure below.
- Start - Programs - ABB industrial IT 800xA System - System Installation Shell -Continue System installation
56
Manual start of installation, this requires a System Planner diskette
- Start - Programs - ABB industrial IT 800xA System - System Installation Shell - Setup a new system
Manually Installation Start
Manually Installation Start
Click on Browse
57
Manually Installation Start Browse after the stored installed package. File ending *.cct
Press Next
Manually Installation Start Example: *.cct file stored on floppy A:\
Press Next
58
Automated installation, this requires a System Planner diskette.
Installation Start This is the start of the installation of Industrial It on your computer. This will automatically start when you have done a silent Windows installation.
Press Next
Installation Wizard The wizard shows what is about to be done.
Press Next
59
Network Settings On the installation the network settings from the diskette will be used.
Press Next
Network Settings Shows computer name and network settings.
Press Next
60
Network Checklist
Press Next
Network Checklist
Press Next
61
Restart
Finish
Installation
Press Next
62
Installation Wizard
Press Next
Windows Components
Press Next
63
Checklist Windows
Press Next
Checklist Windows
Press Next
64
Restart
Press Next
Installation Wizard
Press Next
65
Choosing Workgroup Here you choose the workgroup you want to use.
Press Next
Checklist Windows
Press Next
66
Checklist Windows
Press Next
Restart
Press Next
67
Installation Wizard
Press Next
Add Groups Creating the groups used in the 800xA program. Use the default settings.
Press Next
68
Add Users Setting up the users.
Press Next
Create Service Account Setting up the service account in Windows.
Press Advanced
Input password. We have used Narvik8515.
Press Next
69
Checklist Windows
Press Next
Checklist Windows
Press Next
Insert the IIT800xA-41-1 DVD#1 in the DVD-rom.
Press OK
70
Installation Wizard
Press Next
System Checker Gives you general information about the system. Also checks if you have the needed administrator rights.
Press Next
71
System Checker Checks if your PC satisfy the requirements.
Press Next
System Checker Checks if needed programs are installed.
Press Install
This has to be done until all required programs are installed.
Press Next
Restart the PC
72
Installation Wizard
Press Next
Installation Wizard
Press Next
73
Check user rights
Press Next
Check hardware
Press Next
74
System Checker Checks if the Windows components where installed.
Press Install If there is a program missing, press install on it.
Press Next
System Checker Checks if 3rd programs are installed.
Press Install Install the programs needed.
Press Info This will give additional information on the 3rd party programs needed.
75
WMI SNMP Provider This message appears when pressing info. Follow this to install WMI SNMP.
WMI SNMP Provider Mark the Management and.. as shown in the figure.
Press Details
76
WMI SNMP Provider Mark the checkbox as shown in the figure.
Press OK
Press Next When Windows Component Wizard window opens. This will install the component.
System Checker
Press Next When all 3rd party programs have been installed1.
1 Visual Basic 6.0 does not need to be installed at this point.
77
System Checker Displays the installation report.
Press Finish
Backup We have chosen not do make a backup in the installation.
Press Skip
78
Install Industrial IT This is when you start to install the Industrial IT software.
Press Install
Choose installation medium Choose the medium you want to install the software package from.
Press Cancel
79
Information Box
Press OK
Installation Write the password you have chosen in the password block.
Press Next
80
Installation Settings that will be executed.
Press Next
Installation
Press Next
81
Installation The rest of the steps are automated. When installation is complete, do a restart of the computer. The installation takes time and you should not restart the computer or start any other programs while install.
82
Appendix VI. Post installation After system installation has been done, your new system must be configured on your computer. This is a walkthrough of what is necessary to do in the post installation.
Open Post installation document file [6]. Follow this instruction and start Configuration wizard from the Start menu as shown in Figure 22.
Figure 22 Configuration Wizard start
Configuration wizard window will pop up, as shown in Figure 23 1. Chose Create system, see Figure 23. After choosing your configuration options
the system will configure itself with your options. This configuration will take approximately 35 minutes. Do nothing on your computer while this is being installed.
2. Check that connectivity server is running. 3. Check that firmware version in AC 800M controller is similar to the version in the
program Control builder M professional.
Figure 23 Configuration Wizard