3
IS0694 REV. A 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 3 Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. MOUNTING LOCATIONS Skydome ® Edge Surface Mount FSDESM-22|33|44 KEY POWER OFF POWER ON ATTENTION WEIGHTS: 2’ - 24.0 LBS 2 PEOPLE RECOMMENDED FOR INSTALLATION 3’ - 46.0 LBS 2 PEOPLE RECOMMENDED FOR INSTALLATION 4’ - 80.2 LBS 3 PEOPLE RECOMMENDED FOR INSTALLATION 5.00" 5.00" 5.00" 5.00" .77" 5.00" 5.00" 5.00" 5.00" J-BOX ACCESS 4.55" 2.27" 7.70" 4.84" 3.47" J-BOX ACCESS 8.10" 4.05" 12.00" 7.54" 4.25" J-BOX ACCESS 4' DIAMETER 3' DIAMETER 2' DIAMETER SKYDOME EDGE INSTALLS IN ONE DIRECTION ONLY ALLOW MINIMUM 12" BETWEEN LUMINAIRE AND WALL/OBSTRUCTION IN OPPOSITE DIRECTION OF LUMINAIRE INSTALLATION
Transcript
Page 1: Skydome Edge Surface Mount€¦ · pO wer Off pOwer ON ATTeNTION weIGhTS: 2’ - 24.0 LbS 2 pe pL ereCOMM Nded f r INSTALLATION 3’ - 46.0 LbS 2 peOpLe reCOMMeNded fOr INSTALLATION

IS0694 REV. A 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 3

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

MOUNTING LOCATIONS

Skydome® Edge Surface Mount

FSDESM-22|33|44

key

pOwer Off

pOwer ON

ATTeNTION

weIGhTS:2’ - 24.0 LbS2 peOpLe reCOMMeNded fOr INSTALLATION

3’ - 46.0 LbS2 peOpLe reCOMMeNded fOr INSTALLATION

4’ - 80.2 LbS3 peOpLe reCOMMeNded fOr INSTALLATION

5.00" 5.00" 5.00" 5.00"

.77"

5.00"

5.00"

5.00"

5.00"

J-BOX ACCESS

4.55"

2.27"

7.70"

4.84"

3.47"

J-BOX ACCESS

8.10"

4.05"

12.00"

7.54"

4.25"

J-BOX ACCESS

4' DIAMETER

3' DIAMETER

2' DIAMETER

SKYDOME EDGE INSTALLS IN ONE DIRECTION ONLY

ALLOW MINIMUM 12" BETWEEN LUMINAIRE AND WALL/OBSTRUCTION IN OPPOSITE DIRECTION

OF LUMINAIRE INSTALLATION

Page 2: Skydome Edge Surface Mount€¦ · pO wer Off pOwer ON ATTeNTION weIGhTS: 2’ - 24.0 LbS 2 pe pL ereCOMM Nded f r INSTALLATION 3’ - 46.0 LbS 2 peOpLe reCOMMeNded fOr INSTALLATION

Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited.

IS0694 REV. A 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 3

3

2' / 3' dIAMeTer

4' dIAMeTer

X4

X4

4

MAKE ELECTRICAL CONNECTIONS

CONNeCT MOUNTING pLATe GrOUNd wIreTO LUMINAIre GrOUNd wIre

4' dIAMeTer

SUSPEND LUMINAIRE USING THE LANYARDS 5

LeAve GrOUNd wIre eXpOSed fOr eLeCTrICAL CONNeCTION (STep 4)

INSTALL CeILING pLATe TO STrUCTUre AbOve USING 4 X 1/4”-20 bOLTS (by OTherS)

INSTALL CeILING pLATe TO STrUCTUre AbOve USING 8 X 1/4”-20 bOLTS (by OTherS)

2' / 3' dIAMeTer

4' dIAMeTer

2' / 3' dIAMeTer

6

1 prOperLy OrIeNT ANd ALIGN SkydOMe edGe wITh MOUNTING pLATe2

LIfT TO eNGAGe SLOTS ON reAr Of LUMINAIre wITh TeeTh ON MOUNTING pLATe. SLIde LUMINAIre IN The dIreCTION Of The ArrOw INdICATed ON MOUNTING pLATe.

ALIGN SLOTS ON reAr Of LUMINAIre wITh TeeTh ON MOUNTING pLATe.

2' / 3' dIAMeTer 4' dIAMeTer

7

Page 3: Skydome Edge Surface Mount€¦ · pO wer Off pOwer ON ATTeNTION weIGhTS: 2’ - 24.0 LbS 2 pe pL ereCOMM Nded f r INSTALLATION 3’ - 46.0 LbS 2 peOpLe reCOMMeNded fOr INSTALLATION

Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited.

IS0694 REV. A 2018 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 3

4

DRIVER SERVICE

1 2

pULL ANd hOLd Lever TO dISeNGAGe LOCkING MeChANISM

3

CONTINUe hOLdING Lever IN UNLOCked pOSITION whILe pULLING LUMINAIre IN dIreCTION Of Lever

SUSPEND LUMINAIRE USING THE LANYARDS

5

7

CLAMp CAbLe TO SUSpeNded reAr COver

86

EMERGENCY

SEE BATTERY MANUFACTURER INSTRUCTIONS

eMerGeNCy MAXIMUM MOUNTING heIGhT: 14.25’


Recommended