3
Main Features • Two isolated addressable loops - ring connection • Apollo XP, Discovery and System Sensor (Notifier) protocols • Single or redundant Hot back up configuration • Hot swap card replacement • EN54-2 Certified • SIL-2 Certified according to IEC61508-2 and IEC61508-3 • OnLine configuration via Web Browser • Modbus TCP/IP communication protocol • CIP Safety (Rockwell) communication protocol for SIL application • Customizable third party protocol • 1 slot space into 19” rack SM-ALM
Transcript
Page 1: SM-ALM Main Features - SafCo Engineering · Main Features •Two isolated addressable loops - ring connection •Apollo XP, Discovery and System Sensor (Notifier) ... 32V 32Vdc Power

Main Features• Two isolated addressable loops - ring connection• Apollo XP, Discovery and System Sensor (Notifier) protocols• Single or redundant Hot back up configuration• Hot swap card replacement• EN54-2 Certified• SIL-2 Certified according to IEC61508-2 and IEC61508-3• OnLine configuration via Web Browser• Modbus TCP/IP communication protocol• CIP Safety (Rockwell) communication protocol for SIL application• Customizable third party protocol• 1 slot space into 19” rack

SM-ALM

Page 2: SM-ALM Main Features - SafCo Engineering · Main Features •Two isolated addressable loops - ring connection •Apollo XP, Discovery and System Sensor (Notifier) ... 32V 32Vdc Power

Tag Colour FunctionTX-RX Blinking Interface Communication LED

COM Loop Polling LED

MCU Blinking CPU Normal Operation

FAULTSystem is Normal

Common Loop Fault Ch1 or Ch2 Device or Loop

LKGSystem Isolated from Ground

Ground Detection Fault

ALARMSystem is Normal

Common Alarm Ch1 or Ch2 devices

DISSystem is Normal

Common Disable Ch1 or Ch2 devices

SFLTOff System is Normal

Card Fault (blinking is in programming mode)

32V 32Vdc Power supply

24V-1 24Vdc Channel 1

24V-2 24Vdc Channel 2

5V 5Vdc Power supply

3V3M 3Vdc Communication Module (Optional)

3V3 3Vdc Microprocessor

Front Card LEDs Indication

Loop Cable Specifi cationsThe Addressable loop cable shall be twisted shielded pair with maximum 50 Ohm resistance and 1uF capacity.In the loop design, the following limitations shall be considered:

Limits on single channel with 150 mA consumption Maximum resistance 50 Ohm

Limits on single channel with 250 mA consumption Maximum resistance 28 Ohm

Limits on single channel with 500 mA consumption Maximum resistance 12 Ohm

Limits on single channel with 1000 mA consumption Maximum resistance 6 Ohm

Optional redundantSM-ALM

MainSM-ALM

Tag cable label Description Connector PIN

A1+ OUT POSITIVE LOOP1 JA 8

A1- OUT NEGATIVE LOOP1 JA 7

B1+ RETURN POSITIVE LOOP1 JA 10

B1- RETURN NEGATIVE LOOP1 JA 11

A2+ OUT POSITIVE LOOP2 JA 5

A2- OUT NEGATIVE LOOP2 JA 3

B2+ RETURN POSITIVE LOOP2 JA 1

B2- RETURN NEGATIVE LOOP2 JA 6

- NOT USED JA 12

- NOT USED JA 2

- NOT USED JA 4

- NOT USED JA 9

Card Wiring

*JA connection according to the ALM position into the rack

JA JA JA JA JA JA JA JA JA

JA

Confi guration & Connection

loop 1

loop 2

NOTIFIER DEVICES• 99 AUTOMATIC DETECTORS• 99 MODULES (CONTROL, MONITOR, MANUAL CALL POINT)ORAPOLLO DEVICES XP95 - DISCOVERY• 126 DEVICES (DETECTOR, MODULE, SOUNDER, BEACON, MANUAL CALL POINT)

SMOKE DETECTOR

SMOKE DETECTOR

HEATDETECTOR

HEATDETECTOR

MANUAL CALL POINT

MANUAL CALL POINT

FIREBEACON

FIREBEACON

DISCHARGE HORN

DISCHARGE HORN

CONTROL MODULE

CONTROL MODULE

MONITOR MODULE

MONITOR MODULE

RELAYMODULE

RELAYMODULE

NOTIFIER DEVICES• 99 AUTOMATIC DETECTORS• 99 MODULES (CONTROL, MONITOR, MANUAL CALL POINT)ORAPOLLO DEVICES XP95 - DISCOVERY• 126 DEVICES (DETECTOR, MODULE, SOUNDER, BEACON, MANUAL CALL POINT)

RELAY CONTACT:• common fi re• common fault

Page 3: SM-ALM Main Features - SafCo Engineering · Main Features •Two isolated addressable loops - ring connection •Apollo XP, Discovery and System Sensor (Notifier) ... 32V 32Vdc Power

Web BrowserConnecting laptop directly to the RJ45 lan port (password required) is possible to visualize devices status and to confi gure the general and detail parameter of the cards. Standard Windows browser is used for online confi guration.

From the confi guration page is possible to:• Assign the IP address of the card• Confi gure Network• Display Ch1 or Ch2 device status• Download Ch1 or Ch2 device confi guration program

Device Status Page

Network Confi guration Page

SAFCO Engineering S.p.A.Via Caduti del Lavoro, 10/A - 20096 Pioltello (MI) ItalyT. +39 02 95327396 - F. +39 02 [email protected]

SAFCO Engineering S.R.L - Abu Dhabi10th Street - Al Fahim Building, 4th Floor, Offi ce 411P.O. Box 27212 - Mussafah - Abu Dhabi – UAET. +971 (2) 5558006 - F. +971 (2) [email protected]

www.safcoengineering.com


Recommended