+ All Categories
Home > Documents > SM3DUpgrade

SM3DUpgrade

Date post: 20-Oct-2015
Category:
Upload: anwarmusa27
View: 37 times
Download: 0 times
Share this document with a friend
Description:
SM3DUpgrade
Popular Tags:
49
SmartMarine 3D 2011 R1 Upgrade Guide Version 2011 R1 (9.1) May 2012 DSP3D-PE-200078E
Transcript

SmartMarine 3D 2011 R1 Upgrade Guide

Version 2011 R1 (9.1)

May 2012

DSP3D-PE-200078E

Copyright Copyright © 1999-2012 Intergraph Corporation. All Rights Reserved. Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available without proper authorization from Intergraph Corporation. Portions of this software are owned by Spatial Corp. © 1986-2010. All Rights Reserved.

U.S. Government Restricted Rights Legend Use, duplication, or disclosure by the government is subject to restrictions as set forth below. For civilian agencies: This was developed at private expense and is "restricted computer software" submitted with restricted rights in accordance with subparagraphs (a) through (d) of the Commercial Computer Software - Restricted Rights clause at 52.227-19 of the Federal Acquisition Regulations ("FAR") and its successors, and is unpublished and all rights are reserved under the copyright laws of the United States. For units of the Department of Defense ("DoD"): This is "commercial computer software" as defined at DFARS 252.227-7014 and the rights of the Government are as specified at DFARS 227.7202-3. Unpublished - rights reserved under the copyright laws of the United States. Intergraph Corporation P.O. Box 240000 Huntsville, AL 35813

Terms of Use Use of this software product is subject to the End User License Agreement ("EULA") delivered with this software product unless the licensee has a valid signed license for this software product with Intergraph Corporation. If the licensee has a valid signed license for this software product with Intergraph Corporation, the valid signed license shall take precedence and govern the use of this software product. Subject to the terms contained within the applicable license agreement, Intergraph Corporation gives licensee permission to print a reasonable number of copies of the documentation as defined in the applicable license agreement and delivered with the software product for licensee's internal, non-commercial use. The documentation may not be printed for resale or redistribution.

Warranties and Liabilities All warranties given by Intergraph Corporation about equipment or software are set forth in the EULA provided with the software or applicable license for the software product signed by Intergraph Corporation, and nothing stated in, or implied by, this document or its contents shall be considered or deemed a modification or amendment of such warranties. Intergraph believes the information in this publication is accurate as of its publication date. The information and the software discussed in this document are subject to change without notice and are subject to applicable technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document. The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms of this license. No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT. Intergraph is not responsible for the accuracy of delivered data including, but not limited to, catalog, reference and symbol data. Users should verify for themselves that the data is accurate and suitable for their project work.

Trademarks Intergraph, the Intergraph logo, PDS, SmartPlant, FrameWorks, I-Convert, I-Export, I-Sketch, SmartMarine, IntelliShip, INtools, ISOGEN, MARIAN, SmartSketch, SPOOLGEN, SupportManager, and SupportModeler are trademarks or registered trademarks of Intergraph Corporation or its subsidiaries in the United States and other countries. Microsoft and Windows are registered trademarks of Microsoft Corporation. ACIS is a registered trademark of SPATIAL TECHNOLOGY, INC. Infragistics, Presentation Layer Framework, ActiveTreeView Ctrl, ProtoViewCtl, ActiveThreed Ctrl, ActiveListBar Ctrl, ActiveSplitter, ActiveToolbars Ctrl, ActiveToolbars Plus Ctrl, and ProtoView are trademarks of Infragistics, Inc. Incorporates portions of 2D DCM, 3D DCM, and HLM by Siemens Product Lifecycle Management Software III (GB) Ltd. All rights reserved. Gigasoft is a registered trademark, and ProEssentials a trademark of Gigasoft, Inc. VideoSoft and VXFlexGrid are either registered trademarks or trademarks of ComponentOne LLC 1991-2009, All rights reserved. Oracle, JD Edwards, PeopleSoft, and Retek are registered trademarks of Oracle Corporation and/or its affiliates. Tribon is a trademark of AVEVA Group plc. Alma and act/cut are trademarks of the Alma company. Other brands and product names are trademarks of their respective owners.

SmartMarine 3D 2011 R1 Upgrade Guide 3

Contents Contents ..............................................................................................................................3

Preface .................................................................................................................................5

Introduction ........................................................................................................................6

Upgrade Overview ........................................................................................................6

Upgrade Cases ..............................................................................................................7 Document Assumptions ................................................................................................9

Preparing for the Upgrade ..............................................................................................10

Backup the Model and the SharedContent (Symbols) Share .....................................11 Check the Integrity of the Databases ..........................................................................11

Verify the Consistency of Piping Specifications .............................................................. 11 Determine if Synchronize is Required .............................................................................. 12 Synchronize the Version 2009.1 or Version 2011 SP1 Model with the Version 2009.1 or Version

2011 SP1 Catalog .............................................................................................................. 12 Resolve the Version 2009.1 or Version 2011 SP1 To Do List ......................................... 12 Check Version 2009.1 or Version 2011 SP1 Database Integrity ...................................... 13 Verify Reference Files ...................................................................................................... 13

Backup the Model .......................................................................................................14

Prepare the Workstation for the Upgrade ...................................................................14 Prepare the Server for the Upgrade ............................................................................15

Upgrading the SharedContent (Symbols) Share ...........................................................18

Description of the 2011 R1 SharedContent (Symbols) Share Contents .....................18

Upgrade Procedure for the SharedContent (Symbols) Share .....................................20 Upgrading Custom Symbols and Naming Rules ........................................................24 Upgrading SmartMarine 3D Reports Template Files .................................................25

Upgrading SmartMarine 3D Drawings Styles.sha File ...............................................25

Upgrading the Databases ................................................................................................27

Non-Global Workshare Configuration .......................................................................27 Global Workshare Configuration ...............................................................................29 Global Workshare Configuration (Non-Consolidated) ..............................................31

Upgrading the Reference Data .......................................................................................35

Overview .....................................................................................................................35 Incorporate the 2011 R1 Reference Data Changes .....................................................36

Bulkload Changes to Catalogs .......................................................................................... 36

Synchronizing the Model with the Catalog ...................................................................38

Synchronize the 2011 R1 Model with the 2011 R1 Catalog ......................................38

Contents

4 SmartMarine 3D 2011 R1 Upgrade Guide

Resolve the 2011 R1 To Do List ................................................................................39

Check 2011 R1 Database Integrity .............................................................................39

Regenerating the Reports Database ...............................................................................40

Copy Filters from Catalog...............................................................................................41

Appendix I: Upgrading Your Tool Schema...................................................................42

Appendix II: Upgrading Your SmartMarine 3D Reports Template Files .................43

Upgrading to 2011 R1 Reports ...................................................................................43 Impact of Changing the Middle Tier Report dlls to C++ ...........................................44

Appendix III: SharedContent (Symbols) Share Changes in 2011 ...............................45

Preface

SmartMarine 3D 2011 R1 Upgrade Guide 5

Preface This document provides guidelines for upgrading SmartMarine™ 3D (SM3D)

version 2009.1 or version 2011 Service Pack 1 (SP1) Marine configurations (models,

catalogs and supporting files) to version 2011 R1 Marine configurations.

SmartMarine 3D 2011 R1 supports upgrade from the following versions:

Version 2009.1

Version 2011 SP1

Since most of the steps to upgrade are the same regardless of which version is being

upgraded, the document refers to the versions being upgraded as “version 2009.1” or

“version 2011 SP1”. Where there are differences, the document will clearly state the

version to which the special instructions apply.

Note

All Marine configurations from earlier versions need to be upgraded to

version 2009.1 or version 2011 SP1. Please see the appropriate SM3D

Upgrade Guide, delivered with the corresponding version 2009.1 or version

2011 SP1 software, for upgrading to one of these versions.

Steps are also included to upgrade Marine configurations that are in a SmartPlant

Enterprise integrated environment, as well as those in a Global Workshare

configuration.

Important

For Global Workshare configurations, upgrade from version 2009.1 to

version 2011 SP1 requires a consolidation of databases. Steps to

upgrade Marine configurations in a workshare environment have been

incorporated into this document.

For Global Workshare configurations (GWC), upgrade from version

2011 SP1 to SmartMarine 3D 2011 R1 does not require a

consolidation of databases. Steps to upgrade Marine configurations in

a workshare environment have been incorporated into this document.

Because SmartMarine 3D registration information was not upgraded in

SmartPlant Foundation 4.x, SmartMarine 3D must re-register with

SmartPlant Foundation after upgrading to SmartPlant Foundation 4.x.

For a definition of terms used in this guide, refer to the Glossary section in the

Common User’s Guide, available with the Help > Printable Guides command in the

software or with the Help command in the Common task.

Send documentation comments or suggestions to [email protected].

Introduction

6 SmartMarine 3D 2011 R1 Upgrade Guide

Introduction Upgrading is the process of converting an existing model, with all its associated files

and databases, from compatibility with an older version of SmartMarine 3D (SM3D)

to compatibility with the next sequential version of the software. The databases you

must upgrade include the Site, Site schema, Catalog, Catalog schema and Model

databases. The associated files you must upgrade are those that are located in the

SharedContent (Symbols) share. This set of databases (plus the Reports and Reports

schema databases) and files are collectively referred to as the Marine configuration.

Upgrade Overview Important

SmartMarine 3D 2011 R1 supports upgrade from version 2009.1 and

version 2011 SP1. For convenience, this document refers to the

versions being upgraded as “version 2009.1” or “version 2011 SP1”

unless there are steps that apply to only one version.

For Global Workshare configurations, upgrade from version 2009.1 to

version 2011 R1 requires a consolidation of databases. Steps to

upgrade Marine configurations in a workshare environment have been

incorporated into this document.

For Global Workshare configurations (GWC), upgrade from version

2011 SP1 to SmartMarine 3D 2011 R1 does not require a

consolidation of databases. Steps to upgrade Marine configurations in

a workshare environment have been incorporated into this document.

There are six major steps in upgrading SM3D data from version 2009.1 or version

2011 SP1 to version 2011 R1.

Step 1. Prepare for the Upgrade – This step includes backing up your data,

determining the integrity of the databases, and cleaning up the databases as

needed. The databases must be in as clean a state as possible prior to upgrading so

that errors will be minimized during the process. For more information, see

Preparing for the Upgrade, page 10.

Step 2. Upgrade your files in the SharedContnet (Symbols) share – This process

is a set of manual procedures. For more information, see Upgrading the

SharedContent (Symbols) Share, page 18.

Note

SmartMarine 3D 2011 SP1 and later allow custom DLLs to be used without

registering them. For more information, see Upgrading Custom Symbols and

Naming Rules, page 24.

Introduction

SmartMarine 3D 2011 R1 Upgrade Guide 7

Step 3. Upgrade your databases – The software performs this process

automatically; however, you can control it using the Database Wizard and the

Project Management task. For more information, see Upgrading the Databases,

page 27.

Step 4. Upgrade your version 2009.1 or version 2011 SP1 reference data – After

upgrading the databases, your model should have the same functionality as it did

in version 2009.1 or 2011 SP1. However, some new features and fixes in version

2011 R1 may require that you update your reference data to take advantage of

them. This step integrates the additions and modifications that are included in

version 2011 R1 of the software into your version 2009.1 or version 2011 SP1

reference data. You integrate these additions and modifications based on changes

that are documented in the reference data workbooks that are delivered with 2011

R1. Because this step may be a lengthy process, you can delay this process until a

later time and go on to the next step. For more information, see Upgrading the

Reference Data, page 35.

Step 5. Synchronize the Model with the Catalog – This step loads the Catalog

database changes into the model. For more information, see Synchronizing the

Model with the Catalog, page 38.

Step 6. Regenerate the Reports database – For more information, see Regenerating

the Reports Database, page 40.

Upgrade Cases Upgrading from version 2009.1, the platform requirements have changed for servers

and clients for version 2011 R1. Therefore, users must backup the version 2009.1

Marine configuration and restore it using a client/server configuration that has the

new platform requirements for version 2011 R1. Upgrading from version 2011 SP1,

the platform requirements are similar and do not require client/server configuration

changes. The same basic workflow will apply for each Case listed below: In the

course of describing the details of each major step, this document will take into

consideration four possible upgrade scenarios, or cases, each requiring a slightly

different workflow. Before beginning the upgrade process, select the case that applies

to your situation and follow the workflow for that case where applicable.

Case A. In-place upgrade of entire version 2009.1 or version 2011 SP1 site to

version 2011 R1 on one server.

This case assumes a full transition of the Site and all of its Models from version

2009.1 or version 2011 SP1 to version 2011 R1 on the same server. Due to the

platform requirement changes in version 2011 R1 from version 2009.1, the server and

client have to be updated to the new platform requirements before upgrading to

version 2011 R1. However, the platform requirements should not be updated until the

steps in the Preparing for Upgrade section of this document are completed. Then,

version 2011 R1 software should be installed on the server and client and all

databases upgraded in-place.

Introduction

8 SmartMarine 3D 2011 R1 Upgrade Guide

Note

Case A is the only case where upgrade in a GWC is reasonable and

supported.

Case B. Moving (relocating) databases and upgrading them on another

server.

This should be the most common procedure used for version 2009.1 to 2011 R1

upgrades due to platform requirement changes. This is for cases where all Models and

Catalogs associated with the Site are moved from one server, restored on another

server and upgraded. Or when some of the Models are moved to another server and

upgraded while others in the Site remain on version 2009.1 or version 2011 SP1 on

the original server. When Marine configurations from one Site are relocated and

upgraded to another server, the SharedContent (Symbols) folder must also be copied

and upgraded to the new server or location.

Case C. Restoring archived databases and upgrading them with only version

2011 R1 software.

This case deals with archived backups of version 2009.1 or version 2011 SP1 Marine

configurations that are restored in a location where version 2009.1 or version 2011

SP1 is not available. In addition to the full database backup, a corresponding backup

of the SharedContent (Symbols) folder is required.

Case D. Coexistence of version 2009.1 or version 2011 SP1 and 2011 R1

Marine configurations on one server.

This is the most complex case. In general for version 2009.1 Marine configurations,

there can be several Sites on one server, each compatible with a different version of

SM3D. In these cases, all Catalog and Model databases within one SM3D Site must

be in the same SM3D version. SM3D does not support different versions of Catalogs

and Models within one Site database. For version 2011 SP1 or version 2011 R1

Marine configurations, since version 2011 has new platform requirements different

than version 2009.1, all Sites on one server cannot have version 2009.1 Sites as well

as version 2011 SP1 or version 2011 R1. Version 2009.1 does not support the new

version 2011 platform software requirements. Therefore this Case D does not apply to

upgrading to version 2011 R1 from version 2009.1, and either Case A, B, or C will be

applied for all version 2011 R1 from version 2009.1 upgrades.

Notes

If multiple version 2009.1 Marine configurations are replicated in Case

D and just one (or some of them) needs to be upgraded, you must

consolidate the databases being upgraded and transfer them

(backup/restore) to the new Host server which has new platform

software requirements. Once the upgrade process is completed, the

Marine configurations can be reconfigured to a Global Workshare

environment.

If multiple version 2011 SP1 Marine configurations are replicated in

Case D and just one (or some of them) needs to be upgraded, it is

Introduction

SmartMarine 3D 2011 R1 Upgrade Guide 9

recommended but not required to consolidate the databases being

upgraded and transfer them (backup/restore) to the new Host server.

Once the upgrade process is completed, the Marine configurations can

be reconfigured to a Global Workshare environment. For steps to

upgrade Marine configurations in a Global Workshare environment

see Global Workshare Configuration, page 29.

In all cases, when one SharedContent (Symbols) folder is shared by

multiple Marine configurations that will be separated during an

upgrade process (some Models are upgraded to 2011 R1, while others

remain on a previous version) SharedContent (Symbols) must be

copied and upgraded with the upgraded Marine configuration(s).

Document Assumptions The procedures described in this document are based on these assumptions:

1. The Marine configuration and associated files you intend to upgrade to 2011 R1

must already be upgraded to version 2009.1 or version 2011 SP1. SM3D does not

support upgrading directly from versions prior to 2009.1.

2. The Marine configuration and associated files you intend to upgrade must be

updated with the latest “Hot Fix”. If you are unsure whether you have installed

the latest Hot Fix, please check with your Intergraph support representative.

3. The necessary changes described in the Catalog Data workbooks delivered with

version 2009.1 and version 2011 SP1 have been implemented in your workbooks

and bulkloaded to the respective version 2009.1 or version 2011 SP1 Catalog

database.

4. All customized files on the SharedContent (Symbols) share must have

different names than the delivered files they were based on. If the files have

not been renamed, they will be overwritten and your customizations lost after the

upgrade process is complete. If the file containing your customizations is required

to retain the same name as the delivered file on which it was based, contact your

Intergraph support representative for assistance on how to upgrade these files.

Note

This only applies to users that decide to use Option 2 when upgrading

their SharedContent (Symbols) share, see Upgrading Custom Symbols and

Naming Rules, page 24 of this document, this step is not needed if Option

1 is used..

5. For Marine configurations in an integrated environment, SmartPlant Foundation

databases will need to be upgraded to version 3.8.8, 4.2.0, 4.2.1, 4.3.1 or 4.3.2

before upgrading the SM3D databases to 2011 R1.

6. All reference files are accessible by the user account performing the upgrade.

Preparing for the Upgrade

10 SmartMarine 3D 2011 R1 Upgrade Guide

Preparing for the Upgrade Important

Unless otherwise stated, the steps in this section apply to all cases and

must be performed BEFORE starting the upgrade process.

Unless otherwise stated, you must perform the steps in this section on

a Workstation computer on which SM3D version 2009.1 or version

2011 SP1 is installed, as well as the latest Hot Fix(es).

To help diagnose any upgrade problems you encounter, move all logs

and reports you create in this section to a common location where you

can easily access them.

If unresolved or unknown errors remain after performing the steps in

this section, contact Intergraph support.

If you are configured for Global Workshare, upgrading from version

2009.1 to SM3D 2011 R1 requires a consolidation of databases.

If you are configured for Global Workshare, upgrading from version

2011 SP1 to SmartMarine 3D 2011 R1 does NOT require a

consolidation of databases.

For Marine configurations in an integrated environment, SmartPlant

Foundation databases will need to be upgraded to version 3.8.8, 4.2.0,

4.2.1, 4.3.1 or 4.3.2 before upgrading the SM3D databases. For

assistance with upgrading SmartPlant Foundation databases, refer to

the SmartPlant Foundation Installation and Setup Guide, available

with the Help > Printable Guides command in the software.

Notes

You will need the following references to complete this section.

Unless otherwise stated, these guides are available with the Help >

Printable Guides command in the software.

The 2009.1 or 2011 SP1 Project Management User’s Guide.

The 2009.1 or 2011 SP1 Catalog User’s Guide.

The 2009.1 or 2011 SP1 SmartMarine 3D Troubleshooting Guide.

The 2009.1 or 2011 SP1 SmartMarine 3D Database Integrity Guide.

The 2011 R1 SmartMarine 3D Installation Guide.

The utility SP3DTools.exe and its instruction guide SP3DTools.doc,

both of which can be found on the SmartMarine 3D customer support

website in the SP3DTools link.

The 2011 R1 Catalog User’s Guide.

The 2011 R1 Common User’s Guide.

The 2011 R1 SmartMarine 3D Database Integrity Guide.

The 2011 R1 SmartMarine 3D Troubleshooting Guide.

Preparing for the Upgrade

SmartMarine 3D 2011 R1 Upgrade Guide 11

The 2011 R1 SmartMarine 3D Symbols Reference.

The 2011 R1 SmartMarine 3D Reference Data Guide.

The 2011 R1 Project Management User’s Guide.

The 2011 R1 Global Workshare User’s Guide.

For Marine configurations in an integrated environment, SmartPlant

Foundation Installation and Setup Guide.

For Marine configurations in an integrated environment, SmartPlant

SchemaEditor User’s Guide.

Backup the Model and the SharedContent (Symbols) Share

1. For data security, use the Backup command in your Project Management task to

create a backup of your model.

Note

For assistance with the Backup command, refer to the Back Up and

Restore Data section in the version 2009.1 or version 2011 SP1

Project Management User’s Guide, available with the Help >

Printable Guides command in the software.

2. For data security, copy your SharedContent (Symbols) share to a different

location.

Check the Integrity of the Databases Important

It is recommended that regular checking of the database integrity be

made a standard practice.

Verify the Consistency of Piping Specifications 3. Run the Verify Consistency Report command on your version 2009.1 or version

2011 SP1 Catalog database and resolve any reported discrepancies. The command

is available on Tools menu in the Catalog task.

Note

For assistance with the Verify Consistency Report command, refer to

the Consistency Between Piping Specification and Catalog Data

section in the version 2009.1 or version 2011 SP1 Catalog User’s

Guide, available with the Help > Printable Guides command in the

software.

Preparing for the Upgrade

12 SmartMarine 3D 2011 R1 Upgrade Guide

Determine if Synchronize is Required 4. Install the SP3DTools.exe utility from the Customer Support website. For

instructions on how to install and run the utility, refer to SP3DTools.doc that is

delivered with it.

5. Run SP3DTools.exe.

6. Choose Model DB, enter the SharedContent (Symbols) Share, and select Build

Symbol List.

7. If symbols are missing, mismatched, or any site proxies are listed as out-of-date,

then perform the steps in the next section, Synchronize the Version 2009.1 or

Version 2011 SP1 Model with the version 2009.1 or version 2011 SP1 Catalog.

Otherwise, you can skip to Resolve the Version 2009.1 or Version 2011 SP1 To

Do List, page 12.

Synchronize the Version 2009.1 or Version 2011 SP1 Model with the Version 2009.1 or Version 2011 SP1 Catalog

8. Run the Synchronize Model with Catalog command in the Project Management

task.

Notes

In a Global Workshare configuration, and upgrading from version

2009.1 this command should be run after consolidation of all the

databases.

In a Global Workshare configuration, and upgrading from version

2011 SP1 this command should be run at each site.

For assistance with the Synchronize Model with Catalog command,

refer to the Synchronize Model with Catalog Command section in the

version 2009.1 or version 2011 SP1 Project Management User’s

Guide, available with the Help > Printable Guides command in the

software.

Resolve the Version 2009.1 or Version 2011 SP1 To Do List 9. Minimize the number of entries found in the To Do List.

Notes

In a Global Workshare configuration, and upgrading from version

2009.1 To Do List resolution should be after consolidation of the

databases.

In a Global Workshare configuration, and upgrading from version

2011 SP1 To Do List resolution should be performed at each site.

Preparing for the Upgrade

SmartMarine 3D 2011 R1 Upgrade Guide 13

For assistance with resolving items in the To Do List, refer to the To

Do List Messages section in the version 2009.1 or version 2011 SP1

SmartMarine 3D Troubleshooting Guide, both available with the Help

> Printable Guides command in the software.

If there are any objects in your model whose configuration status is not

set to “Working”, it is possible that they will appear in the To Do List

as a result of the Synchronize process.

To resolve non-Working status items so that they no longer appear in

the To Do List, it is necessary to change the configuration status of

those objects from their non-Working value to Working, and refresh

the To Do List.

After being removed from the To Do List, the objects can be changed

back to their original configuration status.

Similarly, all objects assigned to a permission group to which the user

performing the Synchronization process has no write access will

appear in the To Do List.

Check Version 2009.1 or Version 2011 SP1 Database Integrity

10. Perform the procedures to check the integrity of your version 2009.1 or version

2011 SP1 Site, Catalog, and Model databases.

Note

For assistance with checking the integrity of databases, refer to the

version 2009.1 or version 2011 SP1 SmartMarine 3D Database

Integrity Guide, available with the Help > Printable Guides

command in the software.

Verify Reference Files 11. Verify that paths to reference files in the model are correct and that the reference

files are at that location. During upgrade, if the software cannot find the reference

files in a model, either because the files no longer exist at the specified path or the

path is no longer valid, the reference files will be removed from the model.

Information about reference files that are removed during upgrade are written to

the log file.

Note

For assistance with reference files, refer to the version 2009.1 or

version 2011 SP1 Common User’s Guide, available with the Help >

Printable Guides command in the software.

Preparing for the Upgrade

14 SmartMarine 3D 2011 R1 Upgrade Guide

Backup the Model 12. After cleaning up the databases, use the Backup command in the Project

Management task to create a backup of the model.

Note

For assistance with the Backup command, refer to the Back Up and

Restore Data section in the version 2009.1 or version 2011 SP1

Project Management User’s Guide, available with the Help >

Printable Guides command in the software.

Prepare the Workstation for the Upgrade Important

Installing 2011 R1 SM3D client software requires all previous SM3D

installations to be uninstalled.

13. Install the required 2011 Enterprise Platform software on the client.

Note

For assistance installing the required 2011 Enterprise Platform

software, refer to the SmartMarine 3D Installation Guide, available

with the Help > Printable Guides command in the software or on the

Smart 3D media Help folder.

14. Install the 2011 R1 SM3D client software, including the latest 2011 R1 Hot

Fix(es) when available, on the client workstation where you will perform the

upgrade process.

15. If you are in an integrated environment, install version 3.8.8, 4.2.0, 4.2.1, 4.3.1 or

4.3.2 of both SmartPlant Schema Component and SmartPlant Client.

Notes

For Global Workshare configurations, upgrade from version 2009.1 to

2011 R1 requires a consolidation of databases. The upgrade process is

performed from the Host location after consolidation of the databases.

For Global Workshare configurations, upgrade from version 2011 SP1

to SmartMarine 3D 2011 R1 does NOT require a consolidation of

databases. The upgrade process is primarily performed from the Host

location. However, each satellite will require a client workstation with

the latest Project Management installed to complete the upgrade.

For assistance installing version 3.8.8, 4.2.0, 4.2.1, 4.3.1 or 4.3.2 of

SmartPlant Schema and SmartPlant Client, refer to the SmartPlant

Foundation Installation and Setup Guide, available with the Help >

Printable Guides command in the software.

Preparing for the Upgrade

SmartMarine 3D 2011 R1 Upgrade Guide 15

Prepare the Server for the Upgrade Important

The procedures to perform in this section are dependent on the case

that applies to your situation. For more details on each case, Upgrade

Cases, page 7.

Case A and D

1. Uninstall all version 2009.1 or version 2011 SP1 SM3D Reference Data software,

including any Service Packs and Hot Fixes.

Notes

Installing 2011 R1 SM3D Reference Data software requires all

previous SM3D installations to be uninstalled.

For Global Workshare configurations, this step needs to be performed at each

site.

For Case D, which only applies for version 2011 SP1, for more details on each

case, see Upgrade Cases, page 7. Before installing 2011 R1 SM3D Reference

Data software, backup and copy all files from their installation folder to another

location on the server. These files may be necessary if you need to create a new version 2009.1 Site, Catalog and/or Plant in the future.

All Cases A, B, C, and D

1. Install the required 2011 Enterprise Platform software on the server, if not

already.

Notes

For assistance installing the required 2011 Enterprise Platform

software, refer to the SmartMarine 3D Installation Guide, available

with the Help > Printable Guides command in the software or on the

Smart 3D media Help folder.

For Global Workshare configurations, this step needs to be performed at each

site.

2. Install the 2011 R1 SM3D Reference Data software, including the latest 2011

R1 Hot Fix(es) when available, on the server having the 2011 Enterprise Platform

requirements installed.

Notes

For assistance installing the required 2011 Enterprise Platform

software, refer to the SmartMarine 3D Installation Guide, available

with the Help > Printable Guides command in the software or on the

Smart 3D media Help folder.

For Global Workshare configurations, this step needs to be performed at each

site.

3. Create the new SharedContent (Symbols) folder.

Preparing for the Upgrade

16 SmartMarine 3D 2011 R1 Upgrade Guide

Important

Intergraph PPM recommends that you do not create the SharedContent

(Symbols) folder under the product folder. Please copy the

SharedContent folder and move it to another location to be shared.

For more information on upgrading the SharedContent (Symbols)

folder in 2011 SP1 see, Upgrading the SharedContent (Symbols)

Share, page 18.

Case A

1. For version 2009.1 upgrades, using a version 2009.1 workstation with Project

Management installed, restore the Site and the Marine configurations to the

server.

2. For version 2011 SP1 upgrades, the databases should still be located on the server

and there is no need to restore.

Important

Use the Restore command in the Project Management task to restore

the Model(s) if they will keep their original names.

Use the Restore as Copy command in the Project Management task to

restore the Model(s) if one or more Models need to be renamed.

Notes

Using the Restore as Copy mode will remove the registration with an

integrated environment for the new model.

For assistance with the Restore and Restore as Copy commands,

refer to the Backing Up and Restoring Data section in the Project

Management User’s Guide, available with the Help > Printable

Guides command in the software.

Case B

1. Using a version 2009.1 or version 2011 SP1 workstation with Project

Management installed, restore the Site and the Marine configurations to the new

server.

Important

Use the Restore command in the Project Management task to restore

the Model(s) if they will keep their original names.

Use the Restore as Copy command in the Project Management task to

restore the Model(s) if one or more Models need to be renamed.

Notes

Using the Restore as Copy mode will remove the registration with an

integrated environment for the new model.

For assistance with the Restore and Restore as Copy commands,

refer to the Backing Up and Restoring Data section in the Project

Preparing for the Upgrade

SmartMarine 3D 2011 R1 Upgrade Guide 17

Management User’s Guide, available with the Help > Printable

Guides command in the software.

Case C

1. Using a version 2011 R1 workstation with Project Management installed, restore

the Site configuration to the new server.

Notes

For assistance with the Restore command, refer to the Backing Up and

Restoring Data section in the Project Management User’s Guide,

available with the Help > Printable Guides command in the software.

The Restore As Copy command works only when restoring a backup

made with the same version of the software used for restoring. If you

need to rename the Models or the Catalog after the upgrade is

completed, the Model can be Restored as Copy with the new name

from a backup of the upgraded Marine configuration.

Case D

1. Using a version 2011 SP1 workstation with Project Management installed, either

restore the Site from backup with a new name if the upgraded Model(s) and

Catalog will keep the original name, or create a new Site if you intend to use the

Restore as Copy command.

Note

For assistance with the Restore and Restore as Copy commands,

refer to the Backing Up and Restoring Data section in the Project

Management User’s Guide, available with the Help > Printable

Guides command in the software.

2. Using a version 2011 SP1 workstation with Project Management installed, restore

the Model(s).

Important

Use the Restore command to restore the Model(s) to the restored Site

if they will keep their original names after ensuring that they are

already deleted from the original Site.

Use the Restore as Copy command to restore the Model(s) if one of

these two situations apply:

1. One or more Models need to be renamed.

2. The Catalog must be copied and renamed because it is shared by a

Model which is not upgraded.

Upgrading the SharedContent (Symbols) Share

18 SmartMarine 3D 2011 R1 Upgrade Guide

Upgrading the SharedContent (Symbols) Share

Notes

Before continuing with the following procedures, ensure that all

customized files on the SharedContent (Symbols) share have different

names than the delivered files on which they were based.

If the files have not been renamed, they will be overwritten and your

customizations will not be present after the upgrade is complete.

If a file containing your customizations needs to retain the same name

as the delivered file on which it was based, contact your Intergraph

support representative for assistance on how to upgrade this file.

Description of the 2011 R1 SharedContent (Symbols) Share Contents

SharedContent\WBSAssignableNames.txt – A customizable file, that contains a

list of class names that are valid for assignment to a Work Breakdown Structure.

SharedContent\WBSAssignableNames_Manual.txt – A customizable file, that

contains a list of class names that are valid for manual assignment to a Work

Breakdown Structure. Users can delete this manual file. If this file is deleted, the

manual assignment behavior will be the same as versions prior to 2011 R1; no

filtering of objects. All selected objects will be assigned when executing the

AssignToWBSItem command.

SharedContent\Bin – contains piping, equipment, HVAC, Hangers and Support,

Structural Detailing, Structural Manufacturing etc. Intergraph delivered dlls.

SharedContent\BracketEdgeContours - contains Symbol2D generated bracket

edge contours for molded forms

SharedContent\Brackets - contains Symbol2D generated brackets for molded

forms

SharedContent\Chamfers - contains Symbol2D generated chamfers for detailed

plate systems

SharedContent\Collars - contains Symbol2D generated clips and collars for

detailed plate systems penetrated by profiles

SharedContent\CornerFeatures - contains Symbol2D generated corner features for

detailed plate systems and profile systems

SharedContent\CrossSections – contains Symbol2D generated cross-sections for

Structure.

SharedContent\CrossSectionType – contains bitmaps referenced by Structure.

SharedContent\Custom Symbols – directory to be used by customers for custom

dlls.

SharedContent\CustomDoc – storage for custom documentation.

Upgrading the SharedContent (Symbols) Share

SmartMarine 3D 2011 R1 Upgrade Guide 19

Important

Delivered files in this folder cannot be renamed, however, their

contents can be modified. Any customizations made to these files can

be copied back into the 2011 R1 files.

SharedContent\Data – contains bitmaps referenced by Hangers and Supports,

custom schema and mapping files for Reference 3D, and mapping files for

Translators.

SharedContent\Drawings – catalog location for the Drawings and Reports

environment.

SharedContent\DrawingsWrappers – contains additional catalog files for the

Drawings and Reports environment.

SharedContent\EdgeFeatures - contains Symbol2D generated edge features for

detailed plate systems and profile systems

SharedContent\FlangeContours - contains Symbol2D generated flange contours

for bracket plate systems with flange as reinfrorcement

SharedContent\FlangeCuts - contains Symbol2D generated flange cuts for

detailed profile systems

SharedContent\HangersAndSupports – contains Symbol2D files referenced by

Hangers and Supports.

SharedContent\HoleMgmt - contains Symbol2D generated hole cuts

SharedContent\Labels – catalog location for labels.

SharedContent\MarineLibrary - contains Symbol2D generated symbols and

display bitmaps specific to the new marine library

SharedContent\NozzleOrientations – contains bitmaps used to display nozzle

properties.

SharedContent\Openings – contains bitmaps and Symbol2D generated cross-

section for Structure’s opening command.

SharedContent\Penetrations - contains Symbol2D generated slots for detailed

plate systems penetrated by profile systems

SharedContent\PmfgIsoStyleData – catalog information for the various styles

used to create piping isometric drawings.

SharedContent\Profile Xsections - contains Symbol2D generated cross sections

for profile systems placed in Molded forms

SharedContent\Reports – catalog location for reports.

SharedContent\ShapeTypes – contains bitmaps and xml definition of Shapes.

SharedContent\ShipDrawings - contains Symbol2D generated symbols used in

marine drawings

SharedContent\Sketched Features - contains Symbol2D generated sketched

features for detailed profile systems

SharedContent\SmartPlantStructure – additional bitmaps referenced by Structure.

SharedContent\SolidEdgeParts – contains Solid Edge par and asm files for

Equipment.

SharedContent\StructManufacturing - contains Symbol2D generated symbols for

manufactured parts, profiles and members

SharedContent\SymbolIcons – contains bitmaps referenced by route.

Upgrading the SharedContent (Symbols) Share

20 SmartMarine 3D 2011 R1 Upgrade Guide

SharedContent\Web Cuts - contains Symbol2D generated web cuts for detailed

profile systems

SharedContent\Xml – contains files used by SM3D to work with SmartMarine

integrated environment. It also includes the SystemSymbolConfig.xml and

CustomSymbolConfig.xml files that are necessary for on-the-fly registration of

delivered and custom DLLs.

Upgrade Procedure for the SharedContent (Symbols) Share

Important

The procedures to perform in this section are dependent on the case

that applies to your situation. For more details on each case, refer to

Upgrade Cases, page 7.

In the steps that follow, the contents of the 2011 R1 SharedContent

(Symbols) share will be copied onto the contents of your version

2009.1 Symbols or version 2011 SP1 SharedContent (Symbols) share.

However, for Marine configurations in an integrated environment,

DO NOT copy the contents of the 2011 R1 SharedContent\Xml

folder onto the contents of your version 2009.1 Symbols or version

2011 SP1 SharedContent (Symbols) share. See Appendix I:

Upgrading Your Tool Schema, page 42. However, the

SystemSymbolConfig.xml file from the 2011 R1 SharedContent

(Symbols) share should be copied onto the version 2009.1 Symbols or

version 2011 SP1 SharedContent (Symbols) share. This file contains

information necessary for on-the-fly registration of delivered DLLs.

For all Cases A, B, C and D

1. Copy the contents of your existing version 2009.1 Symbols or version 2011 SP1

SharedContent (Symbols) share to its location on the server.

2. If you have customized the file Styles.sha located in the SharedContent or

Symbols\Drawing\templates folder, create a backup of this file. After completing

the remaining steps in this section, follow the steps in Upgrading SmartMarine

3D Drawings Styles.sha File, page 25, to finish the upgrade of this file.

3. Rename the bin folder in the 2009.1 Symbols or version 2011 SP1 SharedContent

(Symbols) folder to bin_2009.1 or something similar. The 2011 R1

SharedContent folder has been reorganized to have discipline-related folders

under the bin folder. If you do not rename the old bin folder, you will have

duplicate DLLs after upgrading the SharedContent (Symbols), and the entries for

the duplicate DLLs will not appear in the SystemSymbolConfig.xml file after

running the Update Custom Symbol Configuration command.

4. If working in an integrated environment, rename the XML folder to XML_2009.1

or something similar. The files in the SharedContent\XML folder will be modified

Upgrading the SharedContent (Symbols) Share

SmartMarine 3D 2011 R1 Upgrade Guide 21

later in the upgrade process. If the version 2009.1 or version 2011 SP1 files are

overwritten with the 2011 R1 files, the upgrade will fail for Marine

configurations in an integrated environment. This is the reason for renaming

the folder. See Appendix I: Upgrading Your Tool Schema, page 42.

5. Copy the contents of the delivered 2011 R1 SharedContent (Symbols) share over

your Model’s version 2009.1 Symbols or version 2011 SP1 SharedContent

(Symbols) share. DO overwrite files with the same name, after ensuring you

have renamed the version 2009.1 or version 2011 SP1 SharedContent

(Symbols) files that you have customized.

Note

The SharedContent (Symbols) folder cannot be shared by Models

using different versions of SM3D. Therefore, the upgraded Marine

configuration must use its own copy of the SharedContent (Symbols)

folder, while the original Symbols or SharedContent folder stays in

version 2009.1 or version 2011 SP1.

6. Sign Assemblies

Intergraph Process, Power & Marine signs all delivered .NET assemblies with a

strong name. Signing an assembly is a way to guarantee the authenticity of an

assembly. If you create your own custom .NET assemblies, we recommend that

you sign them with your company's private key. Refer to Visual Studio help for

information on signing an assembly.

7. Grant Trust to Client Computers

To utilize .NET based commands, symbols or rules, your administrator must

apply the required security setting in order to enable .NET code from Shared

Content (Symbols) to be trusted. This is required because by default in .NET all

code from a network location is untrusted. If adding trust is not done, you will

receive the following error message when running a .NET command: "Not able

to get the ThirdParty Plugin from the Catalog Rule or Default Rule". In addition,

you will not be able to place objects using .NET symbols in the model. This is

also required before Bulkloading .NET symbols, as doing so may put existing

objects in the To Do List. You must set each computer that uses the signed

assemblies trust access to the assemblies. The most convienent way to do this is

to generate an msi file on one client machine and distribute the permissions to

each client computer. You will need the .NET Framework 2.0 Configuration

utility, which is available in the .NET Software Development Kit. You can also

search the Microsoft web site for "configwizard.msi download".

1. Install the .NET Framework 2.0 Configuration utility on a client computer.

2. Select Start > Control Panel > System and Security > Administrative

Tools > Microsoft .NET Framework 2.0 Configuration.

Upgrading the SharedContent (Symbols) Share

22 SmartMarine 3D 2011 R1 Upgrade Guide

3. In the Console Root tree, expand .NET Framework 2.0 Configuration >

My Computer > Runtime Security Policy > Machine > Code Groups >

All_Code > LocalIntranet _Zone.

4. Under Tasks, click Add a Child Code Group.

5. Select Create a new code group.

6. In the Name box, type Delivered Smart 3D Content

7. Click Next.

8. In the Choose the condition type for this code group, select Strong

Name.

9. Click Import.

10. Browse to and select one of the signed assemblies.

Important

You need to select one of the Intergraph Process, Power & Marine signed

assemblies from the shared content folder. All Intergraph Process, Power

& Marine assemblies are signed with the same key, so it does not matter

which assembly you select. You can also select from the product location,

eg

[Smart3DWorkstationInstallationDirectory]\Core\Container\Bin\Assembli

es\Release\CommonMiddle.dll.

The public key displays.

11. Clear the Name check box.

12. Clear the Version check box.

Note

By clearing the Name and Version check boxes, the computer trusts all

assemblies that were signed with the same strong name key.

13. Click Next.

14. Select FullTrust from Use existing permission set.

15. Click Next.

16. Click Finish.

17. Right-click Runtime Security Policy, and then select Create

Deployment Package.

18. Select Machine.

19. Specify the file name and folder location for the .msi file.

20. Click Next.

Upgrading the SharedContent (Symbols) Share

SmartMarine 3D 2011 R1 Upgrade Guide 23

21. Click Finish. This should generate the msi file with the given name in the

specified folder.

22. Distribute the .msi file to each client. You can do this using the Remote

Installation approach allowed by Microsoft.

Important

After you do this procedure for the Intergraph Process, Power & Marine

assemblies, you need to repeat the steps for the custom assemblies that

you have created and signed.

Command Line Alternative

If you wish to do it in an alternative manner, instead of creating and distributing

msi files, you can run a command line executable to grant the client computer

access to the assemblies on the shared content share. You must run the following

executable as an administrator from a command-line window on each client

computer:

"C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\caspol.exe" -pp off -

machine -addgroup LocalIntranet_Zone -url \\server\share\* FullTrust -name

"SharedContent Share"

where \\server\share is the computer name and share name for the SharedContent

share.

Important

You must rerun this command line each time a .NET assembly is added to

the share.

The above process should be run on all client machines that need to utilize

.NET symbols.

In order for Remote IFC to utilize .Net symbols, the above process should

be run on all Remote IFC Server machines.

8. Copy the Structure subfolder, SystemSymbolConfig.XML,

MapClassIdToLevelDiscipline.txt, OptimizationForRole – Marine Sample.xml,

and OptimizationForRole – Plant Sample.xml files from the newer XML folder

and overwrite the files in the version 2009.1 or version 2011 SP1 XML folder

renamed in the previous step. Remove the newer XML folder and rename the

version 2009.1 or version 2011 SP1 XML folder back to XML.

9. For Marine configurations in an integrated environment, ensure that the files in

the SharedContent\Xml folder are not Read-only.

DesignBasisSchema subfolder

EFUpdateCache subfolder

Designbasis_map.xml

Upgrading the SharedContent (Symbols) Share

24 SmartMarine 3D 2011 R1 Upgrade Guide

Designbasis.xml

ExemptCorrelateClasses.xml

P3DComponent.xml

SP3DPublishMap.xml

SPItoSP3DPortMapping.xml

10. If you have customized any files on the SharedContent (Symbols) share (for

example, report template files, etc.) that were based on a delivered template file,

you may need to modify this file to incorporate Intergraph’s fixes and

enhancements. Refer to Appendix II, starting on page 43. If so, do one of the

following:

1. Implement Intergraph’s 2011 R1 changes into your version 2009.1 or

version 2011 SP1 customized file.

OR

2. Repeat the customizations you made in version 2009.1 or version 2011

SP1 in the new 2011 R1 file.

11. See Appendix III, starting on page 45, for a list of symbol files that have version

number changes that may require additional action to update existing occurrences

in the model.

Note

For Global Workshare configurations, make sure any template file

changes are incorporated into each site’s SharedContent (Symbols)

share.

Upgrading Custom Symbols and Naming Rules Important

Custom symbols and naming rules components (custom DLLs) written

in Visual Basic must be migrated from version 2009.1 or version 2011

SP1 to 2011 R1.

A custom component is a symbol or naming rule written by a user or a

user modified version of components provided by Intergraph.

Custom symbols and naming rules written in Visual C++ should to be

migrated to 2011 R1 in the standard way (see Option 2 below).

SmartMarine 3D 2011 R1 allows custom DLLs to be used without

registering them. You can take advantage of this feature by adopting

migration option 1. Or you can choose to go with option 2, which is

using custom DLLs as they are used in version 2009.1 or version 2011

SP1 and earlier versions.

Upgrading the SharedContent (Symbols) Share

SmartMarine 3D 2011 R1 Upgrade Guide 25

Note

Custom COM components (for symbols or naming rules) written in

Visual C++ should not be placed on symbol share in 2011 R1.

Option 1: Move Custom DLLs to SharedContent Directory

For more information and steps on how to manage and move Custom DLLs to the

SharedContent directory , refer to the 2011 R1 Project Management User’s Guide,

available with the Help > Printable Guides command in the software.

Or

The same information is also in each [Discipline name] 3D Symbols Reference

document, available with the Help > Printable Guides command in the software.

Option 2: Continue to Use the Custom DLLs as They Are

With this option the custom DLLs can be used as they are used in Version 2007 (7.x)

and earlier. This means that the custom DLLs will be registered on each client

software installation. Some of the custom DLLs may have to be recompiled on the

Version 2011 (9.0) platform. If you select this option, then there is no impact except

the recompilation impact in some cases. Recompiled DLLs must be distributed to

each client machine.

Upgrading SmartMarine 3D Reports Template Files 1. If you have created custom reports based on any of the delivered report templates,

or if you want to incorporate the modified or new report files delivered in 2011

R1, review Appendix II: Upgrading Your SmartMarine 3D Reports Template

Files, page 43, for steps to incorporate the changes into your own custom or

delivered reports, if necessary.

Upgrading SmartMarine 3D Drawings Styles.sha File

Important

These steps are only necessary if you have customized the file

Styles.sha and after performing the steps in Upgrading the

SharedContent (Symbols) Share, page 18. These steps assume that the

delivered Styles.sha file is located in the

SharedContent\Drawing\templates folder on the SharedContent

(Symbols) share and that your customized file is backed up at some

other location.

1. Rename the delivered Styles.

2. Copy your customized Styles.sha file to the SharedContent\Drawing\templates

folder on the SharedContent (Symbols) share and rename it, if necessary, with the

name “Styles.sha”.

Upgrading the SharedContent (Symbols) Share

26 SmartMarine 3D 2011 R1 Upgrade Guide

Note

The steps below are only necessary if you need to incorporate new

line styles included in the delivered file that are not included in

your customized Styles.sha.

3. Open your customized Styles.sha file.

4. Select the Format > Style menu item. The Style form appears.

5. On the Style form, select Resources.

6. Select the Add button on the Style Resources form.

7. On the Add form, browse to the delivered Styles.sha file that you renamed and

select OK.

8. Select OK on the Style Resources form.

9. Select Apply then Close on the Style form.

10. Place a line using one of the new line styles included with the delivered file. This

will permanently copy the new line style to your customized Styles.sha file.

11. Delete the line.

12. Repeat the previous two steps for each line style you want to add to your

customized Styles.sha.

13. Save and exit the customized Styles.sha file.

Upgrading the Databases

SmartMarine 3D 2011 R1 Upgrade Guide 27

Upgrading the Databases Important

For Global Workshare configurations, upgrade from version 2009.1 to

2011 R1 requires a consolidation of databases. See Global Workshare

Configuration, page 29.

For Global Workshare configurations, upgrade from version 2011 SP1

to 2011 R1 does NOT require a consolidation of databases. See Global

Workshare Configuration, page 29.

Notes

You will need the following references to complete the steps in this

section.

The 2011 R1 Project Management User’s Guide, available with the

Help > Printable Guides command in the software.

The 2011 R1 SmartMarine 3D Reference Data Guide, available with

the Help > Printable Guides command in the software.

For Marine configurations in an integrated environment, SmartPlant

Foundation Installation and Setup Guide.

Non-Global Workshare Configuration Cases A, B, and D

1. Using the 2011 R1 client workstation that includes the Project Management

component, upgrade the Site and Site schema databases.

Note

For assistance with this step, refer to the Upgrade a Site Database

section in the 2011 SP1 Project Management User’s Guide, available

with the Help > Printable Guides command in the software.

2. Using the 2011 R1 client workstation that includes the Project Management

environment, upgrade the Catalog and Catalog schema databases.

Note

For assistance with this step, refer to the Upgrade the Catalog and

Catalog Schema Databases section in the 2011 R1 Project

Management User’s Guide, available with the Help > Printable

Guides command in the software.

3. Using the 2011 R1 client workstation that includes the Project Management

environment, run the Tools > Update Custom Symbol Configuration command.

This command creates or updates a file called CustomSymbolConfig.xml under

the ..\SharedContent\Xml folder. After the file CustomSymbolConfig.xml is

created, SmartMarine 3D will use the custom DLLs from

..\SharedContent\Custom Symbols folder.

Upgrading the Databases

28 SmartMarine 3D 2011 R1 Upgrade Guide

Note

All custom symbols have to be located in the ..\SharedContent\Custom

Symbols folder and have to be unregistered on the system running the

Update Custom Symbol Configuration command.

4. For Marine configurations in an integrated environment, run the Generate Design

Basis command from the 2011 R1 client workstation that includes the Project

Management component.

Note

For assistance with this step, refer to the Generate the Design Basis

section in the 2011 R1 Project Management User’s Guide. You can

access this guide using the Help > Printable Guides command in the

software.

5. Using the 2011 R1 client workstation that includes the Project Management

component, upgrade the Model database.

Note

For assistance with this step, refer to the Upgrade the Ship (Model

Database) section in the 2011 R1 Project Management User’s Guide.

You can access this guide using the Help > Printable Guides

command in the software.

Case C

1. Using the 2011 R1 client workstation that includes the Project Management

component, upgrade the Site and Site Schema databases.

Note

For assistance with this step, refer to the Upgrade the Site and Site

Schema Databases section in the 2011 R1 Project Management User’s

Guide. You can access this guide using the Help > Printable Guides

command in the software.

2. Using the 2011 R1 client workstation, restore the Model with Catalog in the

upgraded Site on the new server.

Note

For assistance with the Restore command, refer to the Backing Up and

Restoring Data section in the 2011 R1 Project Management User’s

Guide, available with the Help > Printable Guides command in the

software.

3. Using the 2011 R1 client workstation that includes the Project Management

component, upgrade the Catalog and Catalog schema databases.

Note

For assistance with this step, refer to the Upgrade the Catalog and

Catalog Schema Databases section in the 2009.1 Project Management

Upgrading the Databases

SmartMarine 3D 2011 R1 Upgrade Guide 29

User’s Guide, available with the Help > Printable Guides command

in the software.

4. Using the 2011 R1 client workstation that includes the Project Management

environment, run the Tools > Update Custom Symbol Configuration command.

This command creates or updates a file called CustomSymbolConfig.xml under

the ..\SharedContent\Xml folder. After the file CustomSymbolConfig.xml is

created, SmartMarine 3D will use the custom DLLs from

..\SharedContent\Custom Symbols folder.

Note

All custom symbols have to be located in the ..\SharedContent\Custom

Symbols folder and have to be unregistered on the system running the

Update Custom Symbol Configuration command.

5. For Marine configurations in an integrated environment, run the Generate Design

Basis command on the 2011 R1 client workstation that includes the Project

Management component.

Note

For assistance with this step, refer to the Generate Design Basis

Command section in the 2011 R1 Project Management User’s Guide.

You can access this guide using the Help > Printable Guides

command in the software.

6. Using the 2011 R1 client workstation on which the Project Management

component is installed, upgrade the Model database.

Note

For assistance with this step, refer to the Upgrade the Model Database

section in the 2011 R1 Project Management User’s Guide, available

with the Help > Printable Guides command in the software.

Global Workshare Configuration All Cases A, B, C, and D – for version 2009.1 to verison 2011 R1 upgrades

Notes

For Global Workshare configurations, upgrade from version 2009.1 to

2011 R1 requires a consolidation of databases. The upgrade process is

performed from the Host location after consolidation of the databases.

See the 2011 R1 Global Workshare User’s Guide for more detailed

instruction.

1. At the Host location, use the version 2009.1 client workstation that includes the

Project Management component to consolidate the Marine configuration.

Upgrading the Databases

30 SmartMarine 3D 2011 R1 Upgrade Guide

Note

For assistance with this step, refer to the section Consolidate Ship from

Workshare section in the 2009.1 Global Workshare User’s Guide,

available with the Help > Printable Guides command in the software.

2. After consolidation, check that all permission groups belong to the Host location.

Then follow the steps detailed in the Non-Global Workshare Configuration, page

27.

3. After all upgrade steps in Non-Global Workshare Configuration section have

been completed, the databases can be replicated again if desired.

Notes

For assistance with this step, refer to the section Consolidate Ship from

Workshare section in the 2011 R1 Global Workshare User’s Guide,

available with the Help > Printable Guides command in the software.

All Cases A, B, C, and D – for version 2011 SP1 to verison 2011 R1 upgrades

Notes

For Global Workshare configurations, upgrading from version 2011

SP1 to SmartMarine 3D 2011 R1 does NOT require a consolidation of

databases, but it is an option to do so. Continue to the next step.

If upgrade in a non-consolidated state is required then follow the next

section “Global Workshare Configuration (Non-Consolidated)”.

See the 2011 R1 Global Workshare Guide for more detailed

instruction.

1. At the Host location, use the version 2011 SP1 client workstation that includes the

Project Management component to consolidate the Plant configuration.

Note

For assistance with this step, refer to the section Consolidate Plant

from Workshare section in the 2011 SP1 Global Workshare User’s

Guide, available with the Help > Printable Guides command in the

software.

2. After consolidation, check that all permission groups belong to the Host location.

Then follow the steps detailed in the Non-Global Workshare Configuration, page

27.

Notes

For assistance with this step, refer to the section Consolidate Plant

from Workshare section in the 2011 SP1 Global Workshare User’s

Guide (SQL Server) or Global Workshare User’s Guide (Oracle),

available with the Help > Printable Guides command in the software.

Upgrading the Databases

SmartMarine 3D 2011 R1 Upgrade Guide 31

Global Workshare Configuration (Non-Consolidated)

Cases A – for version 2011 SP1 to verison 2011 R1 upgrades

Important

The procedures to perform in this section only apply for Case A in a

Global Workshare configuration.

Notes

For Global Workshare configurations, upgrading from version 2011

SP1 to SmartPlant 3D 2011 R1 does NOT require a consolidation of

databases. Continue to the next step. See the 2011 R1 Global

Workshare Guide for more detailed instruction.

For more details on each case, refer to Upgrade Cases, page 7.

1. At the Host location, using the version 2011 R1 client workstation that includes

the Project Management component, upgrade the Site and Site schema databases

using the Database Wizard.

Notes

For assistance with this step, refer to the Upgrade the Site and Site

Schema Databases section in the 2011 R1 Project Management User’s

Guide, available with the Help > Printable Guides command in the

software.

A message will display specifying scripts which need to be executed

manually on the Site and/or Site Schema databases for each Satellite

location.

If there are non-trusted satellites in the work share then the below

message will be displayed with Yes and No options.

Failed in establishing trusted connection to one or more satellite

servers involved in the Global Work share configuration.

Host Server / Database: ServerName / DatabaseName

Migration will treat them as untrusted sources and generate the

required scripts to manually migrate them. Do you want to

continue?

On selecting Yes, the migration will proceed further and on selecting

No the migration will not continue.

2. At the Host location, using the version 2011 R1 client workstation that

includes the Project Management component, upgrade non-replicated

views by executing all of the scripts and views detailed in the upgrade

SiteDBName_ReadMe.txt file.

a. Script information is recorded in the upgrade

SiteDBName_ReadMe.txt file.

Upgrading the Databases

32 SmartMarine 3D 2011 R1 Upgrade Guide

b. Scripts and upgrade SiteDBName_ReadMe.txt file are created in

the C:\Temp\SatelliteMigration folder.

Steps to execute script(s) on SQL Server databases:

1. Run the individual Satellite_Instance name

_SiteDBNameMigration_X.bat file on the corresponding Satellite

location.

Note

X is the location Id of the satellite. Based on the number of

satellites, the respective number of .bat files will be created.

For non-trusted satellites, the respective .bat file and the sql file need

to be copied to the satellite location and be executed manually.

2. Repeat the above step for each Satellite location.

3. Run the AddToPublications_.bat file to execute the script.

4. Ensure that all data is replicated between the Host and Satellite(s)

before performing the next view generation step.

5. Regenerate the Site and Site Schema views on each Satellite using

the View Generator. The View Generator executable,

ViewGenerator.exe, is delivered in the [Product

Folder]\Core\Tools\Administrator\Bin folder.

3. At the Host location, using the version 2011 R1 client workstation that includes

the Project Management component, upgrade the Catalog and Catalog schema

databases.

Notes

For assistance with this step, refer to the Upgrade the Catalog and

Catalog Schema Databases section in the 2011 R1 Project

Management User’s Guide, available with the Help > Printable

Guides command in the software.

A message will display specifying scripts which need to be executed

manually on the Catalog and/or Catalog Schema databases for each

Satellite location.

4. Using the version 2011 R1 client workstation that includes the Project

Management component, perform step 2 from the Option 1: Move

Custom DLLs to SharedContent Directory section. For more details,

refer to Option 1: Move Custom DLLs to SharedContent Directory,

page 24.

5. At the Host location, using the version 2011 R1 client workstation that

includes the Project Management component, upgrade non-replicated

views by executing all of the scripts and views detailed in the upgrade

CatalogDBName_ReadMe.txt file.

a. Script information is recorded in the upgrade

CatalogDBName_ReadMe.txt file.

Upgrading the Databases

SmartMarine 3D 2011 R1 Upgrade Guide 33

b. Scripts and upgrade CatalogDBName_ReadMe.txt file are created

in the C:\Temp\SatelliteMigration folder.

Steps to execute script(s) on SQL Server databases:

1. Run the individual Satellite_Instance name

_CatalogDBNameMigration_X.bat file on the corresponding

Satellite location.

Notes

X is the location Id of the satellite. Based on the number of

satellites, the respective number of .bat files will be created.

For non-trusted satellites, the respective .bat file and the sql

file need to be copied to the satellite location and be executed

manually.

2. Repeat the above step for each Satellite location.

3. Run the AddToPublications_.bat file to execute the script.

4. Ensure that all data is replicated between the Host and Satellite(s)

before performing the next view generation step.

5. Regenerate the Catalog and Catalog Schema views on each

Satellite using the View Generator. The View Generator

executable, ViewGenerator.exe, is delivered in the [Product

Folder]\Core\Tools\Administrator\Bin folder.

6. In an integrated environment at the Host location for Marine configurations, run

the Generate Design Basis command from the version 2011 R1 client

workstation that includes the Project Management component.

7. If Generate Design Basis was performed, regenerate the Catalog and Catalog

Schema views on each Satellite using the View Generator.

Note

For assistance with this step, refer to the Generate Design Basis

Command section in the 2011 R1 Project Management User’s Guide.

You can access this guide using the Help > Printable Guides

command in the software.

8. At the Host location, using the version 2011 R1 client workstation that includes

the Project Management component, upgrade the Model database.

Notes

For assistance with this step, refer to the Upgrade the Model Database

section in the 2011 R1 Project Management User’s Guide. You can

access this guide using the Help > Printable Guides command in the

software.

A message will display specifying scripts which need to be executed

manually on the Model database at each Satellite location.

9. At the Host location, using the version 2011 R1 client workstation that

includes the Project Management component, upgrade non-replicated

Upgrading the Databases

34 SmartMarine 3D 2011 R1 Upgrade Guide

views by executing all of the scripts and views detailed in the upgrade

ModelDBName_ReadMe.txt file.

a. Script information is recorded in the upgrade

ModelDBName_ReadMe.txt file.

b. Scripts and upgrade ModelDBName_ReadMe.txt file are created in

the C:\Temp\SatelliteMigration folder.

Steps to execute script(s):

1. Run the individual Satellite_Instance

name_ModelDBNameMigration_X.bat file on the corresponding

Satellite location.

Notes

X is the location Id of the satellite. Based on the number of

satellites, the respective number of .bat files will be created.

For non-trusted satellites, the respective .bat file and the sql

file need to be copied to the satellite location and be executed

manually.

2. Repeat the above step for each Satellite location.

3. Run all the AddToPublications_.bat file(s) on the corresponding

Satellite location.

4. Repeat the above step for each Satellite location.

5. Ensure that all data is replicated between the Host and Satellite(s)

before performing the next view generation step.

6. Regenerate the Model views with Catalog Schema on each

Satellite using the View Generator. The View Generator

executable, ViewGenerator.exe, is delivered in the [Product

Folder]\Core\Tools\Administrator\Bin folder.

Note

To run ViewGenerator on the Model Database, select the Model

database as the Data Database and select the Catalog Schema database

as the Schema Database.

Upgrading the Reference Data

SmartMarine 3D 2011 R1 Upgrade Guide 35

Upgrading the Reference Data Important

Prior to performing the procedures in this section, use the Backup

command in the Project Management task to create a backup of your

upgraded Model. For assistance with the Backup command, refer to

the Back Up and Restore Data section in the 2011 R1 Project

Management User’s Guide. You can access this guide using the Help

> Printable Guides command in the software.

For Global Workshare configurations, you only need to perform the

steps in this section at the Host location.

Notes

You will need the following references to complete the steps in this

section.

The 2011 R1 Project Management User’s Guide, available with the

Help > Printable Guides command in the software.

The 2011 R1 SmartMarine 3D Reference Data Guide, available with

the Help > Printable Guides command in the software.

The 2011 R1 SmartMarine 3D Symbols Reference, available with the

Help > Printable Guides command in the software.

Overview In SmartMarine 3D 2011 R1, numerous changes have been made to the reference

data. These changes, which include enhancements as well as fixes to the data or

software, are incorporated into the reference data workbooks delivered with the

product. The changes are also reflected in the database seed templates provided by

Intergraph.

Notes

The reference data workbooks can be found in the folder [Product

Folder]\CatalogData\Bulkload\Datafiles and [Product

Folder]\ShipCatalogData\Bulkload\Datafiles.

For more information about the reference data delivered with the

software, refer to the Understanding Reference Data section in the

2011 R1 SmartMarine 3D Reference Data Guide, available with the

Help > Printable Guides command in the software.

Upgrading the Reference Data

36 SmartMarine 3D 2011 R1 Upgrade Guide

Incorporate the 2011 R1 Reference Data Changes

Bulkload Changes to Catalogs 1. Decide what reference data changes you want to incorporate from the delivered

Catalog Data workbooks using the next set of procedures:

Using the version 2011 R1 client workstation open the folders [Product

Folder]\CatalogData\BulkLoad\Datafiles and [Product

Folder]\ShipCatalogData\Bulkload\Datafiles to review the most recent

delivered catalog data.

Select the files that correspond to the discipline in which you are interested in.

Review the Revision History worksheet for each file. Note which additions or

changes you want to incorporate into your reference data.

Note

For more information on incorporating 2011 R1 reference data

changes for new functionality into upgraded Marine configurations,

refer to the Reference Data Changes 2011 SP1 to 2011 R1.xls

workbook New Functionality, available in the Upgrade folder on the

product media.

2. For each of the items you note, make changes in your upgraded

workbooks or create your own set of delta workbooks.

3. Using the version 2011 R1 client workstation on which the Bulkload Reference

Data component is installed, bulkload the edited workbooks to the upgraded

Catalog.

Notes

For more information on how to bulkload files to the Catalog database,

refer to the 2011 R1 SmartMarine 3D Reference Data Guide, available

with the Help > Printable Guides command in the software.

Many disciplines support bulkloading in Delete and Replace mode.

For more information on bulkloading in Delete and Replace mode,

refer to the 2011 R1 SmartMarine Reference Data Guide, available

with the Help > Printable Guides command in the software.

Important

When using Delete and Replace mode in the Bulkload Utility, all

existing catalog entries for each worksheet will be deleted and

replaced with the contents of the worksheet being bulkloaded. In cases

where worksheets exist in multiple workbooks (i.e. Pipestock,

PipingGenericDataBolted, PipingCommodityMaterialControlData,

etc.), missing data must be bulkloaded in Append mode to restore

data which was deleted.

Upgrading the Reference Data

SmartMarine 3D 2011 R1 Upgrade Guide 37

When using this model with Piping Specification Rule

worksheets, only data related to those piping materials classes

appearing in the bulkloaded worksheet are deleted and

replaced. All other piping material classes in the database are

unaffected.

4. In a Global Workshare configuration after Bulkloading at the Host location,

regenerate the Catalog and Catalog Schema views on each Satellite using the

View Generator tool. The View Generator executable, ViewGenerator.exe, is

delivered in [Product Folder]\Core\Tools\Administrator\Bin.

Synchronizing the Model with the Catalog

38 SmartMarine 3D 2011 R1 Upgrade Guide

Synchronizing the Model with the Catalog Important

Prior to performing the procedures in this section, use the Backup

command in the Project Management task to create a backup of your

upgraded Model. For assistance with the Backup command, refer to

the Back Up and Restore Data section in the 2011 R1 Project

Management User’s Guide. You can access this guide using the Help

> Printable Guides command in the software.

Notes

You will need the following references to complete the steps in this

section:

The 2011 R1 Project Management User’s Guide, available with the

Help > Printable Guides command in the software.

The 2011 R1 SmartMarine 3D Database Integrity Guide, available

with the Help > Printable Guides command in the software.

The 2011 R1 SmartMarine 3D Troubleshooting Guide, available with

the Help > Printable Guides command in the software.

Synchronize the 2011 R1 Model with the 2011 R1 Catalog

1. Run the Synchronize Model with Catalog command in the Project Management

task.

Notes

In a Global Workshare configuration, this command should be run at

the Host and each Satellite. The Synchronizing Model with Catalog

process should be complete on the Host before started on the

Satellite(s). Also Regenerate the Catalog and Catalog Schema views

on each Satellite using the View Generator needs to be complete after

bulkloading and Synchronizing Model with Catalog is performed at

the Host location, and before the Synchronizing Model with Catalog

process is performed on the Satellite(s).

Review the section Task Limitations When Working in a Global

Workshare Environment in the 2011 R1 Global Workshare User’s

Guide, for more information on this.

For assistance with the Synchronize Model with Catalog command,

refer to the Synchronize Model with Catalog section in the 2011 R1

Project Management User’s Guide. You can access this guide using

the Help > Printable Guides command in the software.

Synchronizing the Model with the Catalog

SmartMarine 3D 2011 R1 Upgrade Guide 39

Resolve the 2011 R1 To Do List 2. Minimize the number of entries found in the To Do List.

Notes

In a Global Workshare configuration, To Do List resolution should be

performed at each site.

For assistance with resolving items in the To Do List, refer to the To

Do List Messages section in the 2011 R1 SmartMarine 3D

Troubleshooting Guide. You can access this guide using the Help >

Printable Guide command in the software.

If there are any objects in your model whose configuration status is not

set to “Working”, it is possible that they will appear in the To Do List

as a result of the Synchronize process.

To resolve non-Working status items so that they no longer appear in

the To Do List, it is necessary to change the configuration status of

those objects from their non-Working value to Working, and refresh

the To Do List.

After their removal from the To Do List, the objects can be changed

back to their original configuration status.

Similarly, all objects assigned to a permission group in which the user

executing Synchronization has no write access will appear in the To

Do List.

Check 2011 R1 Database Integrity 3. Perform the procedures to check the integrity of your 2011 R1 Site, Catalog, and

Model databases.

Note

For assistance with checking the integrity of databases, refer to the

2011 R1 SmartMarine 3D Database Integrity Guide, available with

the Help > Printable Guides command in the software.

Regenerating the Reports Database

40 SmartMarine 3D 2011 R1 Upgrade Guide

Regenerating the Reports Database 1. For Marine configurations in an integrated environment, run the View Generator

tool on the Model database. The View Generator executable

(ViewGenerator.exe) is delivered to [Product

Folder]\Core\Tools\Administrator\Bin.

2. On the 2011 R1 client workstation, run the Regenerate Reports Database

command in the Project Management task.

Notes

In a Global Workshare configuration, regenerating the Reports

database must be performed at each site.

For assistance with the Regenerate Reports Database command,

refer to the Regenerate Reports Database section in the 2011 R1

Project Management User’s Guide, available with the Help >

Printable Guides command in the software.

3. For Marine configurations in an integrated environment, review Appendix I:

Upgrading Your Tool Schema, page 42, for the steps to complete the upgrade.

Copy Filters from Catalog

SmartMarine 3D 2011 R1 Upgrade Guide 41

Copy Filters from Catalog New Drawings and Reports content in 2011 R1 uses filters that are predefined

in a Catalog created in 2011 R1 but do not exist in version 2009.1 or version

2011 SP1 of the software. To use the new content, copy the new set of Default

Filters delivered with the 2011 R1 Catalog database to your upgraded

database by performing the steps outlined in this section. This step is not

mandatory in order for existing version 2009.1 or version 2011 SP1 Drawings

and Reports to run in 2011 R1.

1. Using the Project Management task on the 2011 R1 client workstation,

create a new Site and Catalog using the database templates files delivered

with the software.

Note

For more information on how to create new Site and Catalog

databases, refer to the Create the Site, Catalog, and Schema

Databases section of the 2011 R1 Project Management User’s

Guide, available with the Help > Printable Guides command in

the software.

2. Enter the upgraded model using the 2011 R1 client workstation. From the Catalog

task, select the Copy Filters from Catalog command from the Tools menu and

copy the delivered Catalog filters from the new 2011 R1 Catalog to your

upgraded Catalog. This will create a new “Default Filters (1)” folder. Rename this

folder to “Default Filters – 2011 R1”.

3. Copy the new 2011 R1 Drawings and Report filters from the new “Default Filters

– 2011 R1” folder to the version 2009.1 or version 2011 SP1 “Default Filters”

folder as needed.

Note

For more information on the Copy Filters command, refer to

the Copying Filters Between Catalogs section of the 2011 R1

Catalog User’s Guide, available with the Help > Printable

Guides command in the software.

Appendix I: Upgrading Your Tool Schema

42 SmartMarine 3D 2011 R1 Upgrade Guide

Appendix I: Upgrading Your Tool Schema This section describes the process to upgrade your Tool Schema files on the

SharedContent (Symbols) share. These steps should be done after the upgrade to 2011

R1 is complete.

1. Ensure that the filesin the XML folder in the SharedContent (Symbols) share

are writeable as these files will be upgraded from version 2009.1 or version

2011 SP1 to version 2011 R1.

2. Run the SmartPlant > Upgrade Schema command from the Project

Management task.

Note

For Global Workshare configurations, upgrade from version

2009.1 to version 2011 R1 requires a consolidation of

databases. In previous versions where users could upgrade in a

Global Workshare configuration, the previous step was only

performed at the Host location. Once the upgrade process is

completed, the Marine configurations can be reconfigured to a

Global Workshare environment.

For assistance with the Upgrade Schema command, refer to

the Upgrade Schema Command section in the 2011 R1 Project

Management User’s Guide, available with the Help >

Printable Guides command in the software.

3. Once the Marine configurations are reconfigured in an integrated Global

Workshare environment, copy the following files from the Host location’s

SharedContent (Symbols) share to the same location on each satellite’s

SharedContent (Symbols) share:

a. [SharedContent]\XML\SP3DPublishMap.xml.

b. [SharedContent]\XML\P3DComponent.xml.

c. [SharedContent]\XML\DesignBasis_Map.xml.

Appendix II: Upgrading Your SmartMarine 3D Reports Template Files

SmartMarine 3D 2011 R1 Upgrade Guide 43

Appendix II: Upgrading Your SmartMarine 3D Reports Template Files

This section describes the steps to upgrade your report files to compatibility with

2011 R1. The modified and/or new version of these files is provided with the 2011 R1

software. The section in this document entitled Upgrading the SharedContent

(Symbols) Share, page 18, provides the steps to upgrade your SharedContent

(Symbols) share to get these files.

While most version 2009.1 or version 2011 SP1 reports will run in 2011 R1, there

have been fixes and enhancements made to some of the 2011 R1 report files. If you

have customized any of the delivered version 2009.1 or version 2011 SP1 report files,

you may either make the same modifications in your own customized files or repeat

the same customizations in the 2011 R1 delivered template files.

Upgrading to 2011 R1 Reports In order to incorporate the changes made to version 2009.1 or 2011 SP1 reports in

2011 R1, follow these steps.

1. Copy the modified and/or new report files using the process detailed in

section Upgrading the SharedContent (Symbols) Share, page 18, of this

document.

2. Bulkload the 1_AMD_Delta_2009.1_2011_Reports.xls or

1_AMD_Delta_2011_2011R1_Reports.xls workbook if using the

delivered reports templates, or make similar changes to your customized

reports workbook and bulkload it.

Notes

The 1_AMD_Delta_2009.1_2011_Reports.xls workbook can be

found in the folder [Product

Folder]\CatalogData\Bulkload\AdditionalDataFiles\Delta2009.1to201

1.

The 1_AMD_Delta_2011_2011R1_Reports.xls workbook can be

found in the folder [Product

Folder]\CatalogData\Bulkload\AdditionalDataFiles\Delta2011to2011

R1.

For more information on how to bulkload files to the Catalog database,

refer to the 2011 R1 SmartMarine 3D Reference Data Guide, available

with the Help > Printable Guides command in the software.

3. The new reports in 2011 R1 use filters that are predefined in a Catalog

created in 2011 R1 but do not exist in version 2009.1 or 2011 SP1 version

of the software. The newest filters should have been copied over when

performing the steps outlined in the Copy Filters from Catalog section of

this document page 41. To get the new reports to run, you must copy the

Appendix II: Upgrading Your SmartMarine 3D Reports Template Files

44 SmartMarine 3D 2011 R1 Upgrade Guide

new 2011 R1 Report filters from the “Default Filters – 2011 R1” folder to

the version 2009.1 or version 2011 SP1 “Default Filters” folder as needed.

Impact of Changing the Middle Tier Report dlls to C++

In version 2011, in order to support the transition to 64-bit OS, a number of middle

tier components in the software that were written using Visual Basic 6 have been

converted to C++. This has necessitated a change in the ProgID of the classes of these

components. End users who have written their own reports in Visual Basic 6 will

need to change their code to call the new ProgIDs instead of the old ones.

For example, a call such as

Set m_oDatabaseHelper = CreateObject(“ReportsDatabaseHelper.DatabaseHelper”)

needs to be replaced with

Set m_oDatabaseHelper = CreateObject(“MiddleReportsServices.DatabaseHelper”)

and the report query interpreter recompiled with 2011 R1 for the report to work.

Below table shows all such ProgIDs relevant to reports that must be changed for 2011

R1.

Old ProgID New ProgID

ReportsDatabaseHelper.BulkBindingHelper MiddleReportsServices.BulkBindingHelper

ReportsDatabaseHelper.DatabaseHelper MiddleReportsServices.DatabaseHelper

MiddleReportsServices.LabelServices

RichTextValidation.Validator MiddleReportsServices.RichTextValidator

SP3DReportsRuntime.CFrameWork MiddleReportsServices.ReportsRuntimeFramework

SP3DReportsRuntime.CCacheController MiddleReportsServices.CacheController

SP3DReportsRuntime.CCodeListsCache MiddleReportsServices.CodeListsCache

SP3DReportsRuntime.CFormatting MiddleReportsServices.CurrentFormatting

SP3DReportsRuntime.CFormattingStack MiddleReportsServices.FormattingStack

SP3DReportsRuntime.CReportingDomain MiddleReportsServices.ReportingDomain

SP3DReportsRuntime.CTemplatesCache MiddleReportsServices.TemplatesCache

Appendix III: SharedContent (Symbols) Share Changes in 2011

SmartMarine 3D 2011 R1 Upgrade Guide 45

Appendix III: SharedContent (Symbols) Share Changes in 2011

Intergraph recommends that users do not modify the delivered Shared Content

(Symbols) files, as Intergraph may modify theses delivered files in each release. If a

user needs to modify the delivered files, they should first copy the dll and paste it to

the Custom Symbols folder directly under the Shared Content (Symbols) folder.

Then, this file should be renamed.

Some of the delivered symbols may have symbol definition changes. Neither the

upgrade procedure outlined in this document nor the Synchronize Model with Catalog

command will update already existing occurrences in the model that now have

changed symbol definitions if the major version number of the symbol was not

incremented. If the major version number was changed, then the symbol definition in

the catalog and all occurrences in the model will be updated by this upgrade process.

If the minor version number of a symbol was incremented or a new aspect was added

and the major version number was not incremented, then the symbol definition in the

catalog will not be updated by this upgrade process. If a symbol definition has been

changed and a new occurrence is placed in the model by the following types of

actions, the new occurrence may be different from the already existing occurrence:

Placing new objects

Copy/Paste

Model Data Reuse

Any other command that causes an existing symbol occurrence to recompute

In order to apply the new symbol definition to existing occurrences, a custom

command is available to update all occurrences in the model to match the new symbol

definition. This is only required if the major version is not incremented or an aspect

was added to the symbol definition. For the procedure to run the Update Symbol

custom command (SymbolTestCmds.CUpdateSymbolDefinition) to apply the symbol

definition changes to all existing occurrences in the model, see the Update Symbol

topic in the following reference guides:

Electrical 3D Symbols Reference

Equipment 3D Symbols Reference

Hangers and Supports 3D Symbols Reference

HVAC 3D Symbols Reference

Piping 3D Symbols Reference

Structure 3D Symbols Reference

Appendix III: SharedContent (Symbols) Share Changes in 2011

46 SmartMarine 3D 2011 R1 Upgrade Guide

Notes

In order for insulation to be applied and displayed for a newly placed

nozzle in a model upgraded from version 2009.1 to version 2011 SP1,

the Update Symbol custom command needs to be ran for the following

ProgIds of the NozzleVBsymb.dll symbol.

GSCADNozzleVBSymb.FlangedNozzle

GSCADNozzleVBSymb.HvacNozzle

GSCADNozzleVBSymb.ElbowNozzle

Please be aware that doing so will trigger an update on all existing

connected route features.

For nozzles that already exist in the model before an upgrade is

performed or for nozzles placed in new models created with version

2011 SP1, users do not have to run the Update Symbol command for

insulation to be correctly applied and displayed.

2011 SP1

The following files located in the SM3D 2011 SP1 SharedContent\Bin folder have

different version numbers compared to the SM3D 2009.1 Symbols\Bin folder.

Upgrade and Synchronize Model with Catalog will automatically apply the necessary

updates to existing objects within the model.

SharedContent\Bin\HangersAndSupports\Symbols\Release\hs_S3DStrap.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\hs_S3DUBolt.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\hs_S3DYokeClamp.dll

SharedContent\Bin\SmartPlantStructure\Symbols\Release\SP3DDoorAsm.dll

SharedContent\Bin\SmartPlantStructure\Symbols\Release\SPSSlabAssemblyConnect

ions.dll

SharedContent\Bin\Piping\Symbols\Release\OutfittingCrossSectionsSymbols.dll

SharedContent\Bin\Shapes\Symbols\Release\SketchCSSymbol.dll

SharedContent\Bin\SmartPlantStructure\Symbols\Release\SPSEqpFndMemSys.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMAssyConRul.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMCollarRules.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMCornerFeatRules.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMEdgeFeatureRules.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMEndCutRules.dll

Appendix III: SharedContent (Symbols) Share Changes in 2011

SmartMarine 3D 2011 R1 Upgrade Guide 47

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMPhysConnRules.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMSlotRules.dll

SharedContent\Bin\StructDetail\Symbols\Release\WeldSymbols.dll

SharedContent\Bin\HoleMgmt\SmartOccurrence\Release\HoleRules.dll

2011 R1

The following files located in the SM3D 2011 R1 SharedContent\Bin folder have

different version numbers compared to the SM3D 2011 SP1 SharedContent\Bin

folder. Upgrade and Synchronize Model with Catalog will automatically apply the

necessary updates to existing objects within the model.

SharedContent\Bin\HangersAndSupports\Symbols\Release\FlSample_Part.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\GeneralProfileSymbols.dl

l

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrAssemblySymbols.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrBeamAtt.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrBracketSymbols.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrCTAssemblySymbols

.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrDesignSupportSymbo

l.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrSupDuctParts.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrSupPadSymbols.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrSupShoes.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrSupStructuralSymbol

s.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HgrSupTemporarySymbo

ls.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Anvil.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Bline_Channel.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Bline_Tray.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_FINL_Parts.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Generic.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Halfen_PC.dll

Appendix III: SharedContent (Symbols) Share Changes in 2011

48 SmartMarine 3D 2011 R1 Upgrade Guide

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Hilti_MIParts.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Hilti_MQParts.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_HVAC.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_JIMCBOM.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Lisega.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_LRParts.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Power.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Base.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Bm.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Clmp.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Const.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Dyn.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Iso.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Misc.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Rod.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_RodFit.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Shoe.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Strp.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Trap.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\Hs_Psl_Var.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_S3DDummyLeg.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_S3DGuide.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_S3DWeld.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_SmartCutbackSteel.d

ll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_SmartSteel.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_TrayShip.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Util_Metric.dll

SharedContent\Bin\HangersAndSupports\Symbols\Release\HS_Utility.dll

SharedContent\Bin\HangersAndSupports\Rules\ReleaseHgrPipePartSelRule.dll

Appendix III: SharedContent (Symbols) Share Changes in 2011

SmartMarine 3D 2011 R1 Upgrade Guide 49

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMAssyConRul.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMCornerFeatRules.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMEndCutRules.dll

SharedContent\Bin\StructDetail\SmartOccurrence\Release\SMSlotRules.dll

SharedContent\Bin\HoleMgmt\SmartOccurrence\Release\HoleRules.dll