Certifications Bachelor in Electrical Engineering Certified as a Advanced Oxidation
Specialist National Association of Mold
Professionals HUD Ashra, and Osha 30 Hours PHII Inspections
IAQ Problems Began with the 70’s oil embargo ... energy crisis
Reduced speeds to 55 mph / Thermostats adjusted to 68 heat & 78 A/C Stringent construction codes resulted in energy efficient buildings More synthetic materials used in construction with less air infiltration
• “Sick Building Syndrome” emerged in the 80’s Americans spend 90% of their lives indoors 15 million Americans have asthma (80% increase since 1980) 28 million Americans suffer from hay fever & allergies Air pollution contributes to lung disease, including respiratory tract infections, asthma, and lung cancer
Today the E.P.A., the U.S. House of Representatives & the World Health Organization rank indoor air pollution the
#1 environmental health problem Airborne Biological threats became a concern Mold, mildew and their mycotoxins are exposed as a
serious health threat Airborne staph, pneumonia & MRSA at record high in
hospitals Deadly nosocomial viruses in hospitals with a 55% death rate & over 85,000 deaths per year
Deaths tied to drug-resistant staph "superbug,“ MRSA may exceed those caused by AIDS, said one public health expert commenting on the new study.
More than 90,000 Americans get potentially deadly infections each year.
INDOOR POLLUTION - - It DOES Affect You !
EPA TESTED FOR 20 DIFFERENT HAZARDOUS CHEMICALS
1] 11 CONSISTENTLY FOUND IN ALL HOME LOCATIONS IN 4 STATES
2] INDOOR EXCEEDED OUTDOOR POLLUTION BY 5 TO 10 TIMES
FOR EVERY CHEMICAL, IN EVERY SEASON, IN EVERY CITY.
Potential Effects “CAUSED BY” or “AGRAVATED BY” Pollution !
Nervous System Effects Lung Cancer Itchy Eyes Snoring
Reproductive Effects Irritability Hyperactivity Dry Throat
Cardiovascular Effects AM Cough Sneezing Allergies
Respiratory Distress Depression Asthma Nausea
Afternoon Slump Blue Moods Lethargy Nose Bleed
Forgetfulness Dizziness Headache Uneasy Sleep
Why Me?
HOW - - Is all this possible ?
*REF: EPA docs - - EPA 402-k-93-007; EPA 402k-95005; EPA 400-r-92-012
ANSWER: Overloaded Immune System
• Breathed• Ingested• Contacted• Accumulated
Over Time
POLLUTION & TOXINSPOLLUTION & TOXINS RESULT !RESULT !People become Vulnerable to:
• Disease• Dysfunctions• Distress
Hey, wait
for me !
He doesn’t
even know
we’re here !
Why do I
feel so bad?
Cleaners – Fumes - Paint - Pesticides – Preservatives - Chlorine – Tobacco - Mold -Bacteria - Pollen - Dust - Glues - Building Materials - Dust Mites – Fungi – Furniture - Carpet – Gases - - etc 1000’s
Recent Market SurveyPrimary reason for purchasing an Air Purifier
Total
Health-Related (Net) 70%Chronic Medical Conditions (Subnet) 38%
I/other family member has allergies/alleviates allergy symptoms 30%I/other family member has asthma 7%
General Health Considerations (Subnet) 37%To have healthier/cleaner/better quality air 20%Reduces/removes allergens in the air 8%Reduces/removes pollen 4%
Environment/Home Environment (Net) 36%Cleans the air of dust/reduces dust 15%Odor Control (Subnet) 12%
Elimination of cigarette/smoke odor 7%Have pets in household/want to reduce pet dander 10%
Other Purchase Considerations (Net) 5%
A Look at Filtration…
Hence Only ~ 40% (max) of < 0.5 um
Dangerous” Particulate
The particulates that effect you the most are not being addressed.
Electronic Air Cleaner( POP & Zap Type )
Pleated Media Filter
Fiber-glass Filter
Approx 98% ofParticle countis < 0.50 um
Hence Only ~ 40% (max)of < 0.5 um
“Dangerous” ParticulateGets filtered with
Pleated Mediafilter type !
Pat J AnnisKansas State Univ.
Pollution Results With Filters IF You Get it to the “Box”
Passive Technologies• Filtering
• Ionization … a misunderstood technology
• Electronic Air “Cleaners”
• UV Lights … issue with distance from UV bulb and exposure time
• Portable units …small rooms, inefficient, ineffective, & costly to operate
David T. Simon President of SEECC LLC has been certified to deal with
multitude of IAQ issues. David T. Simon has assisted
in writing and passing HR205 in Ohio for
inspections in all schools and other facilities for IAQ
Issues.
Nature’s Way……to purify the air we breath
• Ionization• Photo Catalytic OxidationUV Radiation Low Level Ozone
Automatic, Proactive & Self-regulating!
The CatalystQuad-metallic Catalytic Coating
Rhodium, Titanium Dioxide, Silver, Copper
Each metal contributes to process:
• Titanium Dioxide forms two highly reactive substances - Hydroxyl Radicals (OH) & Superoxide Ions (O2-1) - both very strong oxidizers• Rhodium converts Nitric Oxide to Nitrogen
and Oxygen• Silver speeds up the Titanium reactions by
up to 3X. Proven to kill bacteria.• Copper has unique abilities to work with
Hydrogen and can improve the functions of Titanium. Also, helps eliminates algae.
The CatalystHydrophilic Coatings
“Hydrophilic” – means the coating absorbs water vapor (H2O) from the air,
creating an abundance of Hydrogen and Oxygen for creation of friendly
oxidizers
Optimum Humidity is 40-60%
OH
O3-
OH
O3-
O2• HO2
H2O2
-
O2-
AOP formation of “Friendly Oxidizers”
These oxidizers are then picked up in the air stream
and dispersed throughout the building …ACTIVELY purifying contaminants!
Broad SpectrumUV Light
Hydroxyl Radicals OHo Hydroperoxyl Radical HO2
Super Oxides O2-
Hydrogen Peroxide Gas H2O2
Ozonide Ions O3-
• HO2
H2O2
• The REME produces and consumes ozone (O3) to facilitate the AOP reactions. Typically 87% of the ozone produced is decomposed in process.
• The REME cell is NOT an ozone generator, (emits ≤ .02 PPM Ozone), in fact can help regulate O3 levels.
• Provides redundancy of oxidizers which react up to 40x faster than ozone alone & without irritation.
• AOP reactants remain effective after leaving cell as a “Purifying Plasma”… dispersed throughout the building ACTIVELY purifying contaminants.
• Starts by continuously sanitizing the duct system & eventually comes back thru to keep coils clean.
• Attacks virtually all organic and microbial compounds, bacteria, viruses, & VOCs, drops particulates & destroys odors within the spaces where we breath!
REME’s advantages
University Testing_____________________________________________________________
Kansas State University:Dr. James Marsden, Regents Distinguished ProfessorMicrobial reduction on Surfaces (Mold, Bacteria & Virus)
University of Cincinnati:Dr. Sergey Grinshpun, Department Head, Center for
Health-Related Aerosol Studies, Department of Environmental Health
Reduction of the Aerosol Particle Concentration Airborne Microbial reduction (Virus)
Syracuse University:Prof. Jianshun Zhang, Director, International Centre for
Indoor Environment and EnergyAirborne VOC Reductions in simulated HVAC system
Kansas State
University
Efficacy of the REME Cell at Reducing Microbial Populations
on Surfaces_____________________________________________________________
• Staphylococcus aureus : 98.5% reduction• MRSA - Methycillin Resistant Staphylococcus
aureus: 99.8% reduction• Escherichia coli : 98.1% reduction• Bacillus spp. : 99.38% reduction• Streptococcus spp. : 96.4% reduction• Pseudomonas aureuginosa : 99.0% reduction• Listeria monocytogenes : 99.75% reduction• Candida albicans : 99.92% reduction• Stachybotrys chartarum : 99.93% reduction
Unipolar Ionization
0
20
40
60
80
100
0 20 40 60 80 100
Time (min)
AC
F=
Cn
atu
ral
de
cay/
Cp
uri
fie
r
particle size 0.01-0.5 µm
Significant Comments ByDr James Marsden, Kansas State Univ, 5/31/05
( Recognized as foremost authority in microbial control )
1] “The Chinese government uses our ( American- EcoQuest )
RCI & low level ozone ( .02 ppm ) technology to
reduce the risk of SARS in subways and buses.”
2] One of the largest cruise ship/ theme park and hotel
chains - - achieved a 99.9% reduction of the Norwalk virus.
This (EcoQuest) technology is now being employed in their
hotel rooms, cruise ships, animal care facilities,
ice machines and dumpsters.
R.E.M.E.Commercial &
Residential5 Models: 500 SF – 10,000 SF
2 Voltage options: 120V -240V
DuctwoRxCell
10
Reflective Electro Magnetic Energy utilizes an electro magnetic energy cell to create Ionized-Hydro-Peroxides™, a friendly oxidizer plasma made from oxygen and humidity. This air purifying plasma is propelled into the HVAC duct or plenum by a silent plasma propulsion module that has no moving parts, yet propels the plasma at 2 cfm. This provides for fan or blower-less operation on a 24-hour basis. The purifying plasma will be propelled through the ducts whether the fan or blower is on or not. This permits a hardwire 110volt plug-in installation that lets the REME run 24/7 without wiring to the fan/blower circuit.
Active not passive technology.
Before and after REME
1st Floor Duct Before
Cladosporium sp. 5 60 Anderson Air Samples
Non-sporulating fungi 1 12 28.3 L/min for 3 min
Penicillium sp. 33 393 1st Floor - Ductwork
Yeast 1 12
TOTAL FUNGAL COUNT IS: 477
No Growth Observed
TOTAL FUNGAL COUNT IS: 0
REVIEWED BY: Rohrbacher
1st Floor Duct After
RAW CT / CFU/M3
What you need to know..Three points to remember about our Air Purification
Technologies……. 1. The only active Air Purification Technology which combines up to
five nature based technologies to synergistically clean indoor air like nature cleans air outdoors using:• Two types of Ionization to reduce particles.• UV and a Catalyst to create Oxygen & Hydrogen based friendly
oxidizers to reduce microbial contaminants (Photo Catalytic Oxidation)• Low-level ozone to reduce odors
2. The only active Air Purification Technology recognized by the NASA Space Foundation and awarded Certified Space Technology status
3. The only active Air Purification with validation testing from multiple universities proving the ability to reduce up to 99.99% of Particulate, Mold, Fungi, Staph (MRSA), Bacteria and Viruses.
SEECC LLC
For a estimate and evaluation
Go to www.seeccllc.comcall Dave@ 1-(330)-507-
7437 or email [email protected]