11
Central Control Module EN USER MANUAL (CCMXX6X) V1.0 Smart Life Solutions
Transcript

Central Control Module

EN

USER MANUAL

(CCMXX6X)

V1.0

Smart Life Solutions

Content

1: Important Safety Information

2: Description and Properties

3: Technical Properties

3.1: Technical Details

3.2: Technical Drawing

4: Installation

4.1: Before Installation

4.2: Mechanical and Electrical Assembly

4.2.1: Return to Factory Settings

4.2.2: Electrical Assembly

4.2.3: Mechanical Assembly

5: Button and Indicators

5.1: LED Indicators

5.2: Button Functions

6: Communication Properties

7: Commissioning

8: Regulations

3

4

4

4

5

5

5

6

6

6

7

8

8

9

9

10

11

1: Important Safety Informat�on

ELECTRIC SHOCK DANGER!

Do not open the product!

Please read th�s manual before us�ng the dev�ce!

Not follow�ng the recommendat�ons �n th�s manual m�ght lead to danger.

The manufacturer GST ELEKTRONİK LTD ŞTİ cannot be hold respons�ble

for any loss or damagesar�s�ng from not follow�ng the �nstruct�ons �n th�s user manual.

Dev�ce �s no longer under warrant after faults ar�s�ng �n these cases.

The dev�ce �s des�gned to control other electron�c dev�ces and operates �n houses.

Incorrect connect�on or usage m�ght cause fire or electr�c shocks.

There m�ght be voltage on the connect�on t�ps even �f the dev�ce �s turned off.

The fuse or power source must always be d�sabled �f the connect�ons w�ll be changed.

Do not operate the dev�ce w�th wet or mo�st hands to avo�d electr�c shock r�sk.

Do not make any changes on th�s dev�ce that are not spec�fied �n the user manual.

Do not leave the dev�ce d�rectly exposed to sunl�ght or other heat sources. Do

not place the dev�ce near open fire or �ntense heat sources such as electr�c

Other dev�ces

The manufacturer GST ELEKTRONİK LTD. ŞTİ. cannot be held respons�ble for

any damages or out-of-warranty �f any unsu�table connect�ons other than the

connect�ons expressed �n the connect�on manual are made w�th other dev�ces.

Th�s product �s des�gned only for �ndoors use �n a dry env�ronment.

Do not use the product �n wet or damp env�ronment such as bathtub, s�nk,

bath and pool.

Dev�ce Clean�ng

Heat Sources and F�re

Do not clean the product w�th solvent (th�nner, gasol�ne, ac�d etc.) or

abras�ve clean�ng products. Avo�d clean�ng w�th vapour clean�ng tools.

heater.

3

2: Descr�pt�on and Propert�es

3: Techn�cal Propert�es

3.1: Techn�cal Deta�ls

Central Control Module w�th �nohom 16 �nput/output �s used for manag�ng dev�ces

that can be operated w�th load open-close commands such as CCMXX6X alarm

control, room-based heat�ng, �llum�nat�on, plug, curta�n-bl�nds.

Power Consumpt�on 9.6W (Max)

Supply Voltage 12VDC

Outputs 8/16 Relay (277VAC 10/16A)

Inputs 8/16 AC/DC Insulated Input

RF 433 Mhz

�nohom OS

2.5mm² screwed electr�c term�nal

IP 20

0 - 50°C

Max 50°C %65 Amb�ent Hum�d�ty

Max 2000m

156mm x 90mm x 58mm

Rack Mount�ng

EN55032:2015, EN55024:2011, EN62368-1

Commun�cat�on

Operat�ng System

Connect�ons

Protect�on Class

Operat�ng Temperature

He�ght

Relat�ve Hum�d�ty

D�mens�ons

Installat�on

EMC Standards

4

CCM1760 8 bu�ld-�n 10A 250VAC and 8 bu�ld-�n 16A 277VAC (�nrush 100A) relay output and 16DC �nput.

CCM17618 bu�ld-�n 10A 250VAC and 8 bu�ld-�n 16A 277VAC (�nrush 100A) relay output and 16AC �nput.

CCM21608 bu�ld-�n 10A 250VAC (�nrush 40A) and 8 bu�ld-�n 16A 277VAC (�nrush 100A) relay output and 16 DC �nput.

CCMXX6Y Y=0 DC INPUT

Y=1 AC INPUT

3.2: Techn�cal Draw�ng

4: Installat�on

4.1: Before Installat�on

Unsu�table connect�ons aga�nst the manual m�ght cause health, l�fe or mater�al

damage r�sk.

- Do not power on the dev�ce before all the connect�ons are completed. - Check the dev�ce user manual to create a secure connect�on.

- Do not make any connect�ons other than the connect�ons spec�fied �n the scheme.

- Do not connect w�th dev�ces that do not comply w�th secur�ty standards.

Mount the dev�ce away from metal surfaces or objects to avo�d any negat�ve

�mpact on the w�reless commun�cat�on performance.

5

inohom

CC

M176X

16

ACOM1

COM2

COM3

COM4

COM5

COM7

COM6

Q1Q0

Q6Q7

I 0I 1I 2I 3

I 4I 5I 6I 7

I 15I 14I 13I 12

I 11I 10I 9I 8

Q15

Q14

Q13

Q12

Q11

Q10

Q9

Q8

12V

+ -

Q5Q4

Q3Q2

COM0

10

A

108mm

58m

m

157m

m

mm0 10 20 30 40 50 Scale 1/1,6

91mm

4.2: Mechan�cal and Electr�cal Assembly 4.2.1: Return to Factory Sett�ngs

4.2.2: Electr�cal Assembly

When you press and hold these two buttons

and wa�t unt�l the LEDs no longer bl�nk,

the dev�ce w�ll return to factory sett�ngs.

S�nce some relays have a common COM connect�on when the relay �s

connected to the comb� bo�ler, leave Q1 output empty �f connected to Q0

and leave Q3 output empty �f connected to Q2. There �s no COM connect�on from

Q8 to Q15. Th�s can be used for d�rect connect�on.

6

inohomCCM1760

16A

CO

M1

CO

M2

CO

M3

CO

M4

CO

M5

CO

M7

CO

M6

Q1

Q0

Q6

Q7

I 0 I 1 I 2 I 3 I 4 I 5 I 6 I 7I 1

5I 1

4I 1

3I 1

2

I 11

I 10

I 9I 8Q15

Q14

Q13

Q12

Q11

Q10

Q9

Q8

12V+ -Q

5Q

4

Q3

Q2

CO

M0

10A

M

K

+ -12V

L

N

SIREN SENSOR

M

L

N

CCM1760 DC Input Connect�on Representat�on

L : Phase

N : Neutral

COM : Common contact po�nt

+,- : Poz�t�ve,Negat�ve poles

Q : Output Connect�on

I : Input Connect�on

M : Curta�n, Bl�nder Motor

K : Comb� bo�ler thermostat connect�on ends

7

inohomCCM1761

16A

CO

M1

CO

M2

CO

M3

CO

M4

CO

M5

CO

M7

CO

M6

Q1

Q0

Q6

Q7

I 0 I 1 I 2 I 3 I 4 I 5 I 6 I 7I 1

5I 1

4I 1

3I 1

2

I 11

I 10

I 9I 8Q15

Q14

Q13

Q12

Q11

Q10

Q9

Q8

12V+ -Q

5Q

4

Q3

Q2

CO

M0

10A

M

M + -12V

L

L

N

N

K

CCM1761 AC Input Connect�on Representat�on

Th�s �s a locked des�gn box su�table for DIN rack mount�ng. D�mens�ons are

des�gned �n standard fuse box form.

4.2.3: Mechan�cal Assembly

8

1: Pull the mount�ng apparatus down.

2: Push the dev�ce to mount�ng bear�ng.

A: Ra�l mount�ng bear�ng

B: Screw mount�ng bear�ng

1

1

AA

A

A

A

B

B

B

2

5.1: LED Ind�cators

5: Buttons and Ind�cators

LEFT RIGHT

inohomCCM176X

16A

CO

M1

CO

M2

CO

M3

CO

M4

CO

M5

CO

M7

CO

M6

Q1

Q0

Q6

Q7

I 0 I 1 I 2 I 3 I 4 I 5 I 6 I 7I 1

5I 1

4I 1

3I 1

2

I 11

I 10

I 9I 8Q15

Q14

Q13

Q12

Q11

Q10

Q9

Q8

12V+ -Q

5Q

4

Q3

Q2

CO

M0

10A

PO

WE

R

ON

CO

MM

UN

ICA

TIO

N

I0I8 I9 I1

0

I11

I12

I13

I14

I15

I1 I2 I3 I4 I5 I6 I7

Q0

Q1

Q2

Q3

Q4

Q5

Q6

Q7

Q8

Q9

Q10

Q11

Q12

Q13

Q14

Q15

inohom

6: Commun�cat�on Propert�es

inohom

SMART TOUCHPANEL

SMART TOUCHPANEL MINI

WEB

RF 433 Mhz

inohomCCM176X

16A

CO

M1

CO

M2

CO

M3

CO

M4

CO

M5

CO

M7

CO

M6

Q1

Q0

Q6

Q7

I 0 I 1 I 2 I 3 I 4 I 5 I 6 I 7I 1

5I 1

4I 1

3I 1

2

I 11

I 10

I 9I 8Q1

5

Q1

4

Q1

3

Q1

2

Q1

1

Q1

0

Q9

Q8

12V+ -Q

5Q

4

Q3

Q2

CO

M0

10A

inohom

RL 1720

NOVA PANEL

MOBILE

CCMXX6X

The dev�ces use �nohom commun�cat�on protocol. CCMXX6X can w�relessly

commun�cate w�th other �nohom products and can learn and sw�tch output state

values of other products.

İnohom IP Gateway dev�ces (Nova Panel/Home Manager) enable manag�ng other

dev�ces �ntegrated to the automat�on v�a the �nternet by enabl�ng the system to

commun�cate on IP layer.

SWITCHOther dev�ces

�ntegrated v�a IPCamera, Intercom, EIO

inohom

9

D�fferent tasks can be ass�gned to �nohom Central Control Module �nput and

outputs. Funct�ons ass�gned to �nput and output are prov�ded by �nohom

5.2: Button Funct�ons

author�sed dealers. Th�s operat�on �s completed by tra�ned techn�cal personnel �n

�mplementat�on program.

When there �s power on the dev�ce, press and hold two buttons for 2 seconds for

the output control mode. The left button selects the output and the r�ght button

changes the state. You can ex�t th�s mode by press�ng and hold�ng two buttons for 2 seconds.

7: Comm�ss�on�ng

The comm�ss�on�ng of the �nohom products after assembly �s completed by the

author�zed �nohom dealers and techn�cal staff. Deta�led management panel

�nterface ensured commun�cat�on and other sett�ngs between the dev�ces.

At comm�ss�on�ng stage, the “FIND” button on the automat�on control panel �nterface �s

used to �dent�fy the related dev�ce.

The LEDs on the dev�ce w�ll bl�nk w�th 1 second �nterval when pressed “FIND” button

and press “STOP” button when the dev�ce �s found.

Then, sett�ng parameters are sent to the related dev�ce w�th “MATCH” button and the

dev�ce becomes operat�onal.

“IO TEST” buttons on the control panel �nterface can be used for test�ng the correct

cable connect�on of the dev�ce. The state of the des�red output can be changed as

on/off and energy flow towards the term�nal �s �dent�fied.

10

8: Regulat�ons

11

Legal Warn�ng

Declarat�on of Conform�ty

GST Elektron�k Elektr�k Yaz�l�m Mak�na Dan. San. Ve T�c. Ltd. St�.

Kemaloz Mah. Deg�rmendere Cad. No:8/A 64100 Usak/Turkey

www.�nohom.com

0090 850 811 82 83

�nfo@�nohom.com

The propert�es, funct�onal�t�es and other product propert�es can be changed w�thout pr�or

not�ce. �nohom reserves the r�ght to rev�ew or update the products, software or documents

w�thout any l�ab�l�ty to not�fy any �nd�v�duals or organ�zat�ons. İnohom �s a trademark of

GST Elektron�k Elektr�k Yazılım Mak�na Dan. San. ve T�c. Ltd. Şt�. All other brand and

product names here�n are the trademarks of the�r respect�ve owners.

The domest�c product�on logo on all the products show

that themanufactur�ng and software are 100% completed

�n Turkey.

The company has ISO 9001 Qual�ty Management, 14001

Env�ronment Management, 45001 Occupat�onal Health

and Safety Standards.

The dev�ces tagged w�th WEEE symbol shall not be d�scarded w�th other

domest�c waste. The product should be del�vered to the related collect�on po�nt

for waste electr�c and electron�c equ�pment recycle.

CE mark �s a free trademark only for author�zed offic�als and th�s mark

does not conta�n any property assurance.

The product box �s manufactured from a recyclable mater�al. Do not d�scard the

package waste w�th domest�c or other waste and recycle package wastes.

9001:2015 14001:2015 45001:2018

Smart Life Solutions


Recommended